Maintenance and Operating Instructions SIS 120P/SISF



Similar documents
M A N U A L

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT

Machine needle shut-off nozzle type HP

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

Fiberstars Lighted Laminar Flow Fountain Installation Manual

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

Instruction Manual EAGLE 500/550 EAGLE 700/750 EAGLE 900/950 EAGLE 1100/1150

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

REPAIR AND MAINTENANCE MANUAL

Stainless Steel Single and Dual Circulation Kits

Hydraulic control unit series

This instruction is valid for all ACD pump models shown on page 2

Drive shaft, servicing

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1

ALMATEC Series CX CX 10 CX 130

PLUMBING CARE AND REPAIR

IMPACT SPRINKLER TROUBLESHOOTING GUIDE

Fiberstars Mini Lighted Laminar Flow Fountains

INSTRUCTION MANUAL. FOR Air Balance Jib Lifter MODELS COVERED:DSL-300 & DSL-300-P

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Front axle components, overview

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

REPAIR INSTRUCTIONS UNDER BODY CYLINDER (UM, UL)

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

Fire Hydrant Troubleshooting

SunMaxx Solar Filling Station Operating Instructions

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

IMPORTANT DOCUMENTATION DO NOT DISCARD!

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Cylinder head, removing and replacing

Before repairing your toilet, you must determine

The Ford Model A Water Pump

Coolflo Safe Touch Shower Mixing Valve ST20015CP

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

TYPE E Main Valve Sizes 3 /8 through 12

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

DeZURIK 3-20" BAW AWWA BUTTERFLY VALVES WITH TRANSFER MOLDED SEAT

INSTALLATION, OPERATION & MAINTENANCE MANUAL

SWIMMING POOL HEAT PUMP Owners Manual

INSTRUCTIONS FOR USE SAFETY PRINCIPLES, OPERATION AND MAINTENANCE FOR. HYDRAULIC PUMP type HP 03L, 05L, 07L volume 3 l, 5 l, 7 l

2006 HEADSHOK Service Video #1

UNIT 7: PLUMBING KEY CONCEPTS. 1. Identify tools for plumbing. 2. Location of shutoff valves for the main and individual fixtures

Turbocharger system components, servicing

INSTALLATION INSTRUCTIONS

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 46 Brakes - Mechanical Components (Page GR-46)

Rear wheel brakes, servicing. Стр. 1 из 45. Note:

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Table Z. Troubleshooting Chart for Air Conditioners. Cause

STC 3S A Series Solenoid Valves

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

TECHNICAL DATA. Dry 122a. November 12, 2013

MP-4V Heavy Duty Riveter / 39048

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Operating Manual. Rotary Drum Filter. Technology You Can Afford. Quality You Can Trust. Model: KC10 KC15 KC30 KC60

DO NOT attempt to repair hub and wheel bearing assembly.

Morini CM 162EI. Technical Data

Installation Instructions S

Service Manual Rol-Lift

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

2100 AD Mirror Elevator Ball Nut Replacement Procedure

HYDRAULIC LIFT TABLE CART 2200-LB.

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

Model No: VS SAFETY INSTRUCTIONS VS INTRODUCTION & APPLICATIONS VS CONTENTS. 2.1 Introduction. 2.

Installation, Maintenance, & Repair Series 4000B/LF4000B

Load Limiter ULS-60 ULS-80 ULS-100 ULS-125. Table of Contents. Assembly Instructions Load Limiter ULS-60, -80, -100, -125

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

OPERATIONS AND MAINTENANCE INFORMATION FOR: THE CANPLAS BACKWATER VALVE THE CHEMTROL BALL SHUT OFF VALVE SUMP PUMPS AND WASTEWATER EJECTOR PUMPS

TECHNICAL SERVICE MANUAL

Select Radiators Installation Guide

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Cooling system components, removing and installing

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Operating Instructions Parts List Manual Scissor Lift Pallet Truck

Submersion/Insertion Toroidal Sensor

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

1 TON FOLDING CRANE CFC1000

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Vacuum Gate Valve DN 100 and DN 150

Front brakes (FN- 3), servicing

FX TYPHOON 12. Table of Contents

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

MGB Chrome Bumper Conversion

Sewer Jetter GuideSM. How to Unclog Drains with Your Pressure Washer. Use this Guide To:

Float and Thermostatic Traps Series H, C and X

Transcription:

Maintenance and Operating Instructions IRRITROL Pop-up sprinkler with integrated valve SIS 120P/SISF

Contents 1. General 2. Safety 3. Description 4. Assembly 5. Commissioning 6. Maintenance 7. Break-down and elimination of the defects 8. Spare parts list 1. General We presume, that you are experienced in the field of irrigation. Therefore we have kept this instruction as brief as possible, and have included such information only, which you must have for the use of this product. A guarantee can be accepted only, if the sprinkler has been operated in accordance with these instructions, and if the defect occurs within the guarantee period. 1.1. Application The sprinkler is used for the uniform distribution of the water. The water should be precleaned, and free of coarse and fibrous impurities. Max. water temperature will be 50 degree C. Max. ambient temperature will be 75 degree C. 2

2. Safety These operation and safety instructions include basic remarks and hints for the assembly, installation, operation, maintenance, inspection and repair. For this reason these instructions must be read by the fitter, as well as by the customers authorised staff, prior to the installation and commissioning. Apart from the general safety instructions of this paragraph the special safety instructions included in other paragraphs of these operating instructions have to be observed also. 2.1. Symbols of hints given in these operating instructions The non-observance of the safety instructions mentioned in these operating instructions can endanger persons, are marked with the general danger symbol especially. Safety instructions which can endanger the sprinkler and its function, if not observed, are specially marked and the word ATTENTION has been inserted. 2.2. Dangers if the safety instructions are not observed Non-observance of the safety instructions can endanger persons as well as the environment and the sprinkler. Non-observance of the safety instructions can result in a loss of all claims for indemnity. 3

3. Description Recommended operating pressure Permissible operating pressure 5 to 6 bar 3 to 8 bar ATTENTION The pressure at the sprinkler must not exceed 10 bar. 4. Assembly (Sprinkler Valve in Head) SIS120-FV SIS120-PV SIS120-PGV Sprinkler to impact 360 with sod cup for natural turf and valve in head Sprinkler to impact 30-330 with valve in head Sprinkler to impact 30-330 with valve in head and artificial grass Flush pipe work thoroughly before assembling ATTENTION Threaded connection on the sprinkler is 1½ female thread. For sealing the thread, Teflon strip has to be used. Installation of the sprinkler should occur according to the Installation layout for PERROT pop-up sprinkler LVZR 22 VAC (see next side). To avoid burden pressure on the conduit pipe use in any rate a sprinkler swing joint. It is recommended to assemble a gravel package, as shown in the installation layout. The connection of the control cables is only allowed with approved watertight connections. To screw the sprinkler on the swing joint hold on to the housing border or use a strap wrench. 4

5. Commissioning / Winterise 5.1.1 Connection Measurements: Sprinkler type SIS 120PV-PGV SIS120FV Installation height 450 mm 660 mm Rising height 99 mm 206 mm Outer Ø housing 246 mm 246 mm Outer Ø lid 180 mm 242 mm 5.1.2 Measurements a) Check of electrical function : Before the water supply to the valve is opened, the coil has to be triggered through a control unit. Through an acoustic click on the coil, the correct electrical function can be determined. (The click arise through attracting the relay armature.) b) Open water supply to the sprinkler slowly. Probably the valve opens for a short time, but after 30 sec. it should close on its own. c) After opening the water supply and after the max. working / operation pressure is reached, every seal has to be checked / examined. d) Check valves and sprinkler for perfect function, when opening the valve manual. e) While operation of the sprinkler, there is the possibility to adjust the desired irrigation sector on the spring stop [14]. f) After the complete ventilation of the sprinkler the current supply to the coil must be stopped, than the sprinkler has to close. 5.2 Winterise Before beginning of the frost period the sprinkler has to be totally drained off. Therefore there must be connected a powerful compressor on the network / main circuit. Open the valve on the sprinkler until only air is coming out of the nozzle. Sprinkler is equipped with a automatic drainage valve and could be winterised by gravity, just by drainage the pipe. After the drainage the solenoid has to be activated at least 5 times, so that remaining water can be pressed out of the solenoid housing. 5

picture 1 6

6. Maintenance Clean interior space of the sprinkler with a industrial type vacuum cleaner or a similar device. Clean / relieve sprinkler housing from overgrown grass. This work should be done conveniently before commissioning in spring. 7. Break-down and elimination of the defects 7.1 Disassembly Unscrew the screws [3] from the lid [2] Take off lid [2] and securing bracket [4]. Unscrew the screws [6] and pull out the sprinkler insert [5]. The sheet metal housing with edge [1] can be pulled out for repair or inspection on the electrical parts in case of the pop-up sprinkler types LVZR 22-2VDC/VAC/VDE Disassembly valve piston Before the following mentioned work is carried out, it must be sure that the sprinkler is depressurised. The solenoid [19] can be screwed out with or without the solenoid adapter [18] by turning anti clockwise. The filter has to be pulled out for cleaning. Pull out the retaining circlip [9] with the installation hook [33]. Push the installation hook from the left (arrow) into the bore and turn the installation hook to the left whilst pulling it out again. Screw the valve lifter [32] into the valve insert [12]. Loosen the valve insert [12] by applying slight blows with the sleeve around the lifting tool. Pull out the valve insert. 7

7.2 Assembling of the sprinkler 7.2.1 Flush sprinkler In case that the valve contains soil particles, the sprinkler has to be flushed before assembling. Assemble flushing equipment [31] in the sprinkler housing (see picture 2) and open water supply. Connect hose on flushing equipment, so that water can be derived. [31] picture 2 7.2.2 Assembly of valve Screw the valve insert [12] with the stainless steel [10] onto the valve lifter [32]. The chambered surface of the stainless steel must point to the valve insert [12]. The valve insert must be greased slightly at the sealing beads [11] and [13] before it is pushed back into the housing. The control drilling between the two sealing beads [13] must point towards the manual control device or ventilating screw during assembly. (±3 degree or ±5mm at the diameter of the sealing beads [11] ). Push the valve insert [12] into the housing accompanied by slight hits with the sleeve around the valve lifting tool. Replace the retaining circlip [9] into the groove by using the pliers [30]. Make sure that the circlip fits properly! If necessary push with the taper at the valve lifter [32] towards the outside. 7.2.3 Sprinkler assembly Place the sprinkler insert with its guide pins [8] in any small groove. Press the flange [7] and fasten with screws. Fit housing lid [2] with securing bracket [4] and screws [3]. The sprinkler is now completely assembled. Now the function can be checked as described under point 5.1. 8

7.3 Break-down and elimination of the defects Break down Cause / reason Elimination Valve opens / closes only manual not by electrical, Coil or coil seat is dirty Remove coil and clean it, see point 7.1. Control signal Supply voltage is too low (24VAC/DC) Check supply voltage and cable connections Coil is broken Check coil resistance (must be appr. ca. 30Ω) Plunger in coil is seated Change coil Valve does not open, even not manual Seal of valve insert is defect Change valve insert (see point 7.1.) Exit for control water on cylinder of the valve is blocked Disassembly control pipe out off connection and blow through backwards Valve does not close, even not manual, The pressure on the sprinkler nozzle is too low. Filter for control water is dirty Leakage in the control water path Valve is blocked Disassembly valve insert and clean filter or change it (see point 7.1.) Check all connections, control pipe and pressure regulators units for leakage s and eliminate them. Disassembly valve and flush pipes (see point 7.1) 7.3.1 How to check sprinklers, which do not open Check solenoid in or at the controller for efficient operation. Engage valve and check at the relief exit of the controller for a brief water splash to come out Exchange solenoid at the controller only when there is no pressure in the line 7.3.2 How to check sprinklers, which doesn t close Control line has not been ventilated completely. Foreign particles are blocking the valve There is a leak in the hydraulic system. The retaining circlip [9] on top of the valve is not fitted correctly and the valve has been pushed out of it's seat by the operating pressure. Check the outlet of the solenoid valve for correct functioning. To implement this, disconnect the control line. The valve at the controller is normally open (without current). Subject to change without prior notice. 9

Attached SIS 120F/ SIS 120P without valve 10

Contents 1. Description 2. Installation 3. Commissioning 4. Adjustments 5. Maintenance / Cleaning / Repair 6. Preparation for winter time 7. Troubleshooting + Solutions 8. Disassembly and assembly of sprinklers 1. Description Recommended operating pressure Permissible operating pressure 5 to 6 bar 3 to 8 bar ATTENTION The pressure at the sprinkler must not exceed 10 bar. SIS120-P Sprinkler to impact 30-330 SIS120-PG SIS120-F Sprinkler to impact 30-330 with artificial grass Sprinkler to impact 360 with sod cup for natural turf 11

2. Installation Dimension Sprinkler type SIS 120P-PG SIS 120F Installation height 370 mm 573 mm Rising height 98 mm 205 mm Outer Ø housing 246 mm 246 mm Outer Ø lid 180 mm 242 mm When installation to the public water supply system, you must pay attention to the regulations of the water utility respectively guideline of the DVGW (Deutscher Verein der Gas- und Wasserfachmänner e.v.). On stony ground, pipes are to be laid in a sand bed. The sand bed should surround the pipe everywhere 10 cm. It is necessary that the installation of the pop-up sprinkler is in the same level as the ground. Under each sprinkler there must be, a gravel packing of 3 10 buckets of gravel, grading approximately 32. A perfect drainage of the sprinkler housing is very important. Pop-up sprinkler Coarse gravel Main pipe Swing joint PE-connection T-piece Flush the pipes proper before installation of the sprinklers 3. Commissioning Pipes must always be filled slowly, that means you must open the gate valve gradual, under observance of the assigned operating pressure. Despite of a thoroughly flushing it may happen that the sprinkler nozzle is blocked. To clean the nozzle you must turn off the nozzle and flush the sprinkler. To unscrew the nozzle you must put a block under the lid or take off the cover. (Use socket spanner) 12

4. Adjustments 4.1 Sectors The sectors of the reference part circle of sprinklers are adjusted by pushing the spring stop at the end, which expand the spring. You achieve a crude adjustment before installation, the fine adjustment should be done on the working sprinkler. 4.2 Casting range The casting range is regulated through the application of different nozzles and pressures. (Further information see catalogue) 4.3 Jet deflector screw (type SIS120P no adjustment available) The jet deflector screw is for adjustment of the near irrigation around the sprinkler. If you screw in further the screw in the water jet, the rainfall consistency around the sprinkler increases, the casting range decreases. If you unscrew the interruption screw the irrigation around the sprinkler decreases and the casting range increases. 5. Maintenance / Cleaning / Repair To clean or suction the housing you must lift the sprinkler by hand or remove the cover from time to time. Examine function of gravel package In case that the sprinkler insert or nozzle head is dirty, only clean it with water. Do not use lubricants or grease, other wise the gliding plate in the sprinkler might be damaged!!! Please dismount defect parts immediately and repair them or send them to repair. 6. Preparation for winter time Before winter the pipe system and the pumping station are to be drained. The drainage valve must be open until the next in commissioning. By sprinklers with a stop valve (H), the water above the stop valve cannot discharge itself. Because of that reason the sprinkler insert of the installation are to be lift on the cover ( e.g. for winterising). When the sprinkler insert are lift, the water can flows out off the guiding housing and air can enter into the conductions. Therefore it is the best to put a piece of wood with approximately 2 cm between cover and housing until the installation is empty. 13

Deckel cover Holzstück peace of wood Gehäuse housing Halteventil Stopvalve 7. Troubleshooting + Solutions Attention!!! Before above-mentioned works are executed, it must be ensure that the valve is pressure-less. In case of less casting range of some sprinklers it might be garbage in the filter. Then you must dismount the sprinkler insert and clean the filter. Flushing the pipe Only with flushing insert, otherwise the water which flows back can take garbage with it in the housing and can than enter to the pipe system. 8. Disassembly and assembly of sprinklers That work can be done with help of standard tools. Disassembly Unscrew slot screws in the cover. Remove screw / nut and pull out sprinkler insert Assembly Tighten sprinkler insert with screw / nut Mount cover with screws and retainer for cover Subject to change without prior notice. 14