Definition of safety functions Application to degraded operating modes and minimum operating requirements

Similar documents
AETNA FIRE ALARM SERVICE CO., INC.

Call reduction guidance for false alarm/ unwanted fire signals

Austin Independent School District Police Department Policy and Procedure Manual

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM INSPECTION AND TESTING FORM

integrated fire and security solutions Maximum protection for buildings

Risk Engineering Guideline

This handbook provides EAS participants summary instructions for conducting EAS notifications and tests of national, state and local alerts.

APPENDIX J INCIDENT MANAGEMENT

MARULENG LOCAL MUNICIPALITY

1.0 Examples on common security provisions/common welfare provisions

INTERIM ADVICE NOTE 179/14

FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION

LOCAL RADIO STATION MODEL VULNERABILITY ASSESSMENT CHECKLIST. Developed by the Toolkit Working Group for the Media Security and Reliability Council

March 1997 &FM. Handbook. Post at all station operator positions. Federal Communications Commission. Emergency Alert System

NETWORK OUTPUT MEASURES CONSULTATION

REVIEWED ICT DATA CENTRE PHYSICAL ACCESS AND ENVIROMENTAL CONTROL POLICY

Risk Management Guidelines

Comprehensive emergency plan for:

WASTE Application Form - Dublin Waste to Energy SECTION J ACCIDENT PREVENTION & EMERGENCY RESPONSE

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions

Building Integration System (BIS)

Voice Over IP Digital Phone Concerns with Security and Fire Alarm Communications Systems

Security Tools. Forms. Physical Security Assessment Security Plan Template Traffic Control Plan Template

BETTENDORF PUBLIC LIBRARY INFORMATION CENTER EMERGENCY RESPONSE AND FACILITY CLOSURE POLICY

Fire Alarm Log Book. Any activity regarding this system must be documented in writing.

FIRE-FIGHTING DESIGN BRIEF REPORT

DISASTER RECOVERY AND NETWORK REDUNDANCY WHITE PAPER

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

GUIDE NOTES FOR SCHOOLS, ACADEMIES AND COLLEGES

OAKPARK SECURITY SYSTEMS LIMITED. Health & Safety Policy. Requests or suggestions for amendment to this procedure

Major Risks and Recommended Solutions

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

The University of Iowa. Enterprise Information Technology Disaster Plan. Version 3.1

Standard Message Library

Fire Alarm Systems Care and Maintenance

ANNEX 9. PUBLIC INFORMATION AND WARNING

Compliance Schedule Handbook

2012 Ontario Building Code Changes Affecting Fire Alarm Systems

TECHNOLOGY RESEARCH AND DEVELOPMENT More Than Alarm Anna Kołodziej-Saramak

Emergency Telecommunicator Training and Certification

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

Health and safety management. Cardinus Risk Management explain why safety comes first with JobWatch powered by BigChange

Application of Honeywell MasterLogic-200 Controller in Highway Tunnel Monitoring Systems

Emergency Plan. This emergency plan provides a format of data essential in an emergency situation.

5162 E. Working in oxygen-reduced atmospheres BGI/GUV-I 5162 E. Information

Inspection, Testing and Maintenance

Colocation Service Level Agreement

EVENT SAFETY MANAGEMENT PLAN. A Small/ Medium Scale Event

Nuclear Power Plant Electrical Power Supply System Requirements

May 26, 2011, Strategic Planner Circle Innovation Management at Siemens Building Technologies Division Lucas Schmid, Head of Strategy

What Should I Expect From My Alarm Monitoring Station?

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

Document Details. 247Time Backup & Disaster Recovery Plan. Author: Document Tracking. Page 1 of 12

SCADA AND SECURITY DISPATCHES ACCORDING TO PRESENT LEGISLATION IN ROMANIA

INTELLIGENT TRANSPORTATION SYSTEMS IN WHATCOM COUNTY A REGIONAL GUIDE TO ITS TECHNOLOGY

SCS1. UNIT TITLE: MAINTAIN HOTEL SECURITY

WIND TURBINE DAMAGE PREVENTION 2014

Directorate of Estates and Facilities EPM FM5. Estates Emergency Incident Response Procedure

The Joint Commission Approach to Evaluation of Emergency Management New Standards

Car Alarm Series 2 B 2 Buttons

CDW Advanced Image Deployment Service Customer Guide

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

Newton Public Schools Security Audits Executive Summary

EDA-Z5008 & Z5020. Radio Fire Alarm System. User Manual

(2) Words and expressions used and not defined in these regulations but defined in the Act shall have the meaning assigned to them in the Act.

REQUIREMENTS RESPECTING THE SECURITY OF OFFSHORE FACILITIES

Monitoring of Natural Hazards With the ImpactSentinel Alarming System An Intelligent Solution

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

WORKING IN CONFINED SPACES GUIDELINES

Safety Systems Review Facilities Management Guidance and specification Version

Emergency Restoration Plan (ERP) Components

INTERIM ADVICE NOTE 65/05 DESIGN OF VEHICLE RECOVERY OPERATIONS AT ROAD WORKS

APPENDIX 7. ICT Disaster Recovery Plan

Flood Preparedness Checklist

More efficiency in office buildings with HVAC, lighting and security

How To Understand The Concept Of Circuit Switching

How can we prevent security breaches?

Fire Safety PROCEDURES January 2011

Rhode Island State Fire Marshal Fire Protection Systems Narrative Reports. What is a Narrative Report?

FEDERAL GOVERNMENT OVERSIGHT OF PIPELINE SAFETY

Security Service de Services sécurité. Security Alarm Monitoring Protocol

Farm Fires Protecting farm animal welfare

Secure Video Surveillance System (SVSS) for Unannounced Safeguards Inspections

CRISIS PREPAREDNESS:

SAFETY MANAGEMENT SYSTEM FOR MAJOR HAZARD FACILITIES - BOOKLET 3: Part 7.17

EMERGENCY COMMUNICATION PLAN

TLIB3078A Inspect, prepare and start an electric tram

Industry Overview. Transportation

RC:

MURPHY SHIPPING & COMMERCIAL SERVICES AZERBAIJAN

More efficiency in schools with HVAC, lighting and security

Technical specifications. Containerized data centre NTR CDC 40f+

Transcription:

INFORMATION MEMONo.23 Definition of safety functions Application to degraded operating modes and minimum operating requirements July 2014, Centre d Études des Tunnels www.cetu.developpement-durable.gouv.fr Ministère de l'écologie du Développement durable et de l'énergie

Safety in road tunnels is based on complex technical, human and organizational systems which may be subject to failure and lead to a more or less degraded operating situation. It is important therefore to take these failures into account in a preventive manner to ensure that the operational response is effective and appropriate in the event of an accident. Given the wide variety of equipment present, a comprehensive approach based on safety functions has been applied to ensure continuity of operations while providing a satisfactory level of safety for users. This memo follows on from the Guide to Road Tunnel Safety Documentation, in particular booklets 4 and 5 relating respectively to Specific Hazard Investigations (SHI) and the Emergency Response Plans (ERP). It has two objectives: contribute to work on the reliability of systems and help develop degraded operating modes and minimum operating requirements. Table of contents 1. Introduction 3 2. Definition of the main safety functions and means of prevention and protection 3 2.1 The main safety functions 3 2.2 The means of prevention and protection 3 3. Correspondence between safety functions and 4 4 Compensatable and non-compensatable and link with degraded operating modes 6 4.1 Non-compensatable 6 4.2 Compensatable 6 4.3 Degraded operating modes 6 5. Development of minimum operating requirements (MOR) 7 5.1 Development of MORs for non-compensatable 7 5.2 Development of MORs for compensatable 7 6. Conclusion 8 Bibliography 8 Disclaimer: Information memos are intended to provide information on a specific technique or issue which is new or inadequately dealt with elsewhere. Readers will find pointers to assist them in their work. The content and any conclusions presented should not be considered as CETU recommendations. Although everything possible is done to ensure the sources used are reliable, CETU or the authors of the memo may not be held responsible for any inaccuracy or error in the information provided. 2

1 Introduction The special features of each tunnel, the specific operating modes, the wide variety of equipment installed (age, characteristics, maintenance procedures, etc. ), as well as the varied communication and electric power network architectures mean that we are faced with complex organizational and technical systems that differ greatly from one tunnel to another. Therefore it is not easy to define a methodology to characterize the minimum levels of system reliability required to ensure the best possible level of safety for users. To achieve this goal, the first step is to introduce and define the safety functions that correspond schematically to the generic actions to be performed by the operator to ensure the safety of tunnel users. A second step is then to identify the the operator needs to implement these safety functions. Finally, the approach results in identifying how each safety function is provided by combining different. This document is based on practices observed by analysing French road tunnel safety documentation and in particular booklets 4 [1] and 5 [2] of the CETU Guide to Road Tunnel Safety Documentation. These booklets help clarify the concept of tunnel safety with respect to the events to be taken into account, the hazards to be identified, degraded modes and Minimum Operating Requirements (MOR). 2 Definition of the main safety functions and means of prevention and protection 2.1 The main safety functions Safety functions are defined in light of the hazards such as identified in Appendix A of the booklet on specific hazard investigations [1] and hazard treatment in operations. [2] They correspond to the goals and major challenges of safety management. They enable this safety management to be streamlined. Some functions concern prevention, others protection, while others apply to both. These functions can be grouped into five main safety functions: prevent incidents/accidents, detect incidents/accidents, alert and inform, limit the consequences of an incident/accident, ensure a return to normal. 2.2 The means of prevention and protection Function implementation requires human and material. Eleven have been identified: Civil engineering work Centralised technical management and supervision Power supplies Lighting Ventilation Fire fighting facilities Incident and fire detection Communication Traffic signs and signals Human related to the tunnel External human Lighting Civil engineering work Ventilation Fire fighting facilities Incident and fire detection Power supplies Prevent incidents and accidents Detect Alert and Inform Limit the consequences of the incident/accident Ensure a return to normal Communication Centralised technical management and supervision External human Human related to the tunnel Traffic signs and signals The main safety functions and means of prevention and protection The table on the following page sets out the main functions broken down into smaller functions as well as the means for their implementation. It shows that each safety function requires several acting simultaneously. Conversely, each resource contributes to one or more safety functions or even to all functions. It thus appears that maintaining certain in working order is essential for the safety of the structure and requires stringent operating constraints in case of failure. 3

3 Correspondence between safety functions and Resources M1-1 roadway and emergency stopping lane Safety Functions F1: prevent incidents/accidents F1-1 F1-2 F1-3 F1-4 monitor the structure, its equipment, the traffic in the tunnel monitor weather conditions, traffic and the external environment ensure safe, comfortable driving conditions keep users informed of traffic conditions M1: Civil engineering M2: Centralised technical management and supervision M3: Power supplies M4: lighting M5: ventilation M6: Fire fighting equipment M7: incident and fire detection M8: communication M1-2 walkways M1-3 drainage M1-4 emergency exits - shelters M2-1 Sensors and actuators M2-2 Site network M2-3 programmable logic controller (PLC) M2-4 Transport and transmission network M2-5 Tunnel Control Station (supervision) M3-1 external electricity supply M3-2 electrical substations and low voltage master distribution panel M3-3 uninterruptible back-up power supply M3-4 water supply M4-1 normal lighting M4-2 emergency lighting M4-3 emergency-evacuation equipment lighting M4-4 marker lights M5-1 sanitary M5-2 smoke extraction M5-3 emergency exits - shelters M6-1 Fire extinguishers M6-2 fire pipe and hydrant M7-1 closed-circuit television M7-2 automatic incident detection (AID) M7-3 smoke opacimetres and gas sensors M7-4 anemometers M7-5 fire detection (equipment rooms) M7-6 fire detection (tunnel) M7-7 safety door opening and fire extinguisher removal M7-8 loop-based counting system M8-1 emergency call network (ECN) M8-2 tunnel operator and emergency service radio broadcasting facilities M8-3 user FM radio broadcasts and message insertion M8-4 mobile telephone broadcasting facilities M9-1 stop lights M9-2 tunnel closure barriers M9: traffic signs and signals M10: human related to the tunnel M9-3 variable message signs M9-4 lane allocation signals M9-5 safety and evacuation equipment signage M10-1 tunnel operator M10-2 patrols M10-3 inspection team M10-4 In-house fire service M11: external human M11-1 emergency services M11-2 law enforcement services M11-3 traffic control centre 4

F2: detect F3: alert and inform F4: limit the consequences of the incident/accident F2-1 F2-2 F3-1 F3-2 F3-3 F4-1 F4-2 F4-3 F4-4 F5: ensure a return to normal detect an incident/accident classify the incident/accident alert the emergency services alert users in the tunnels and at tunnel heads inform users on the network outside the tunnel minimise the number of users in the tunnel and avoiding subsequent accidents limit escalation of the incident while waiting for the emergency services to arrive facilitate evacuation, get users to safety (self-evacuation) facilitate emergency service access and actions check the condition of the structure and perform any urgent work that may be necessary to restore traffic 5

4 Compensatable and non-compensatable and link with degraded operating modes The analysis of the previous table highlights two types of depending on whether or not their failure can be compensated for by resorting to the use of a different type of system. Whereas for certain, membership of one family or another is clear-cut, other may be attached to one or the other depending on the particular circumstances of each tunnel. The definition of compensatable (4.1) and noncompensatable (4.2) facilitates the development of the degraded operating modes that must be defined when preparing the Emergency Response Plan (ERP). 4.1 Non-compensatable The considered here are those whose malfunction or consequent unavailability cannot be offset by the use of equipment of a different type. Hence their unavailability prevents one or more safety functions from being correctly provided and most often results in the tunnel being closed to all or some traffic. 4.2 Compensatable These are for which malfunctions or unavailability may be temporarily compensated for by other types of equipment or by operating measures. They contribute to a safety function, but this may be provided in another way. Their failure leads to compensatory measures being implemented and routine or nonscheduled maintenance (2) actions being initiated. For example, the following can be included in this category depending on the case: user communication systems such as radio, lane usage signals and variable message signs, detection systems such as emergency telephones, video surveillance cameras, automatic incident detection systems, pollution sensors, (opacimetres, carbon monoxide and nitrogen oxide sensors) etc. In particular, this category includes all which are essential to a large part of, if not all of the safety functions: electric power supplies, centralized technical management, operators in the tunnel control centre, etc.. Some, while only contributing to a single function, must also be considered as non-compensatable, such as smoke extraction. Such equipment is typically scaled taking account of redundancy levels (1), enabling backup solutions to be available. Example of a compensatable resource: emergency telephone 4.3 Degraded operating modes The definition of a degraded operation mode requires consideration of: Example of a non-compensatable resource: smoke extraction ventilation system - The nature of the defect (description and quantification of the loss of functionality admissible for an equipment family), possibly specifying the location of the equipment (to avoid the simultaneous loss of several nearby systems); - The compensatory measures likely to be implemented: other equipment, human (first response team to act, patrols, various on-call, etc.) or restriction of traffic; - The duration beyond which the degraded operating mode can no longer be tolerated. The three criteria above are used to define thresholds below which the tunnel must be closed. (1) - Redundancy involves doubling up an equipment item in the event of the failure of one of them. (2) - Maintenance aims to maintain or restore the item to a specified condition to enable it to perform the function specific to it. 6

5 Development of minimum operating requirements The degraded modes of operation in 4.3 will result in the description of the Minimum Operating Requirements (MOR) as defined in booklet 5 of the Guide to Road Tunnel Safety Documentation. 5.1 Development of MORs for noncompensatable In general, non-compensatable equipment is always more or less completely redundant enabling its contribution to safety functions to be relayed in case of a failure. Such provisions are planned at the design phase. Several redundancy levels are then possible. For example, there may be a backup system that performs at the same level as the normal system (e.g.: a normal power supply and a backup power supply that could take over in the event of a failure), almost complete redundancy (e.g.: a normal power supply and a backup power supply that would only take over some of the nominal capacity in the event of a failure), alternatively, there may be partial redundancy (e.g.: for an extraction system consisting of several fans, an additional extractor fan, via a set of dampers, could provide backup in the event of the failure of one of the other fans). The introduction of partial redundancy leads to a degraded operating mode which may require more or less substantial compensatory measures. The drafting of an MOR for a non-compensatable equipment item must take account of the level of redundancy implemented: - If there is a backup system that performs at the same level or almost the same level as the normal system, the MOR is relatively easy to define insofar as the equipment failure will lead to the activation of partial or total redundancy. If the initial failure persists and if the redundancy system malfunctions at the same time, then the tunnel must be closed. - If the redundancy is partial, the MOR must be defined by taking account of the level at which the system is performing when the redundancy is activated. Let's take the example of a longitudinal ventilation system consisting of several booster fans and designed to fight HGV fires. We define the minimum number of booster fans required to fight an HGV fire (Sp) and then define the minimum number required to fight a light vehicle fire (Sv). From this, we obtain two degraded operating modes and one closure situation: In the first mode, one or more booster fan(s) is/are faulty, but the number of functional booster fans is higher than Sp so the tunnel remains open to HGVs and light vehicles. In the second mode, one or more booster fan(s) is/are faulty, but the number of functional booster fans is higher than Sv and lower than Sp so the tunnel remains open to light vehicles only. Two important points need to be made concerning redundancy. The first point relates to the implementation conditions: joint modes must be avoided at all costs (e.g.: two separate data transmission networks supported by the same optic fibre cable). The second point has to do with maintenance. By its very nature, a redundancy system is rarely used. Regular functional tests and trials must therefore be scheduled to check that it is operating properly. 5.2 Development of MORs for compensatable By its very nature, a compensatable equipment item does not need redundancy. Consequently, if it fails, there will need to be another way of performing the safety function that it performed across the entire tunnel or in just a part of it. This raises two questions: what was the equipment's function(s) and what equipment can take over this function in place of the one that has failed? The table in Chapter 3 highlights five essential safety functions and eleven means of implementing them. In some cases, both of the questions raised above are quite easy to answer, especially if just one of the equipment items is faulty (e.g.: the failure of a door-opening switch in a safety recess could be compensated for by permanently showing the images from a camera monitoring this recess on the screens in the Tunnel Control Centre). The correspondence between the five functions and eleven is useful in determining compensation means. This table can either be used to assess the contribution of a resource to the various safety functions, or to identify the resource(s) that is/are capable of performing a given safety function. A given device (e.g.: cameras or emergency exits) are only "effective" within a geographically restricted area and are normally installed on a modular basis. Consequently, from a practical standpoint, this table should be used in relation to homogeneous sections of tunnel. For each basic tunnel section thus defined, this approach leads to a more simplified reasoning by applying the grid in Chapter 3. As in the previous chapter (dealing with non-compensatable equipment), various risk analysis methods can be used to lead this discussion. In practise, a basic section is often a portion of tunnel that is longer than 300 metres, shorter than 500 metres and includes one or more intermediate exits, with this portion being delimited by two emergency exits or by one end of the tunnel and an emergency exit. For information, this approach has been applied by the DiRIF (the operator for tunnels on the national road network that are located within the Île-de-France region),which has adopted the principles set out above. This reflection led to the development of MORs for compensatable or non-compensatable. The tunnel will be closed to all types of vehicle as soon as the number of functional booster fans falls below Sv. Whenever possible, the preference is given to redundancy systems capable of being activated instantaneously and/or automatically. However, in certain circumstances, the implementation of redundancy could lead to an isolated closure of the tunnel. 7

6 Conclusion This first step has enabled the major safety functions in a road tunnel to be clarified and set against the technical and human required to provide them with the purpose of establishing the contribution of each resource to achieving safety objectives and continuity of operations. This document sets out five major functions for road tunnel safety: prevent incidents/accidents, detect, alert and inform, limit the consequences of the incident/accident, ensure a return to normal. Means of prevention and protection are associated to these functions. These are both technical systems as well as human and organisational and can be broken down into eleven. Not all the required to implement safety functions are of equal importance. A matrix of the functions to be provided and the available has resulted in these being classified into two families. The first contains non-compensatable, the second compensatable by other systems. Usually, non-compensatable should be doubled up (be redundant) in order to ensure optimum tunnel safety and availability. The approach adopted has led to MORs being specified for compensatable and non-compensatable. At the end of the day the purpose of this matrix is to enable managers to identify the they must focus on in order to enable users to travel through the tunnel in safe, free-flowing and comfortable conditions. Bibliography [1] Centre d'études des Tunnels, Guide to Road Tunnel Safety Documentation. Booklet 4: specific hazard investigations (SHI), 2003 [2] Centre d'études des Tunnels, Guide to Road Tunnel Safety Documentation. Booklet 5: the Emergency Response Plan (ERP), 2006 Written by: Jérémie BOSSU, Eric CHARLES, Didier LACROIX, Thierry MANUGUERRA, Jean-Claude MARTIN, Hélène MONGEOT, Marc TESSON and Christophe WILLMANN (CETU). Contact: eeg.cetu@developpement-durable.gouv.fr Photo credits: cetu - Devised by: pemaco - Printed by: vassel graphique Centre d Études des Tunnels 25, avenue François Mitterrand Case no. 1 69674 BRON - FRANCE Tel. 33 (0)4 72 14 34 00 Fax. 33 (0)4 72 14 34 30 cetu@developpement-durable.gouv.fr Ministère de l'écologie du Développement durable et de l'énergie www.cetu.developpement-durable.gouv.fr