haze-gard i The objective standard for a clear view Global communication Reliable and Precise



Similar documents
// SUPER technology for precise web viewing: SUPER HANDYScan Be inspired. Move forward.

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

How To Use A Brother Ql700

Precision Lightmeters Made in Germany

// ipq-view Digital web viewing for your quality assurance. Be inspired. Move forward.

73 Series Spectrophotometers

Agilent Cary 60 UV-Vis

Installation and User Guide. RotatIR Automated Rotating Sample Stage Accessory

INTERACTIVE WHITE BOARD MANUAL

data sheet DONATELLO Rev. I emiss - 25/10/ PRO03 code Automatic tissue processor DONATELLO

Test equipment for temperature and its reduction

CFA. Carton Force Analyser

Samsung Portable SSD. Branded Product Marketing Team, Memory Business

KR25i HIGH SPEED, HIGH CAPACITY REFRIGERATED CENTRIFUGE AUTO-LOCK. CQCS Traceability System VIDEOset Display!

Acer LCD Monitor Driver Installation Guide

Multi-Range Programmable DC Power Supplies 9115 Series

We bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement

Artikel-Detailinformationen

User Guide HD-WLU3R1 DriveStation Duo

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

TrueAlarm Fire Alarm Systems

NIRCal Software data sheet

Data Sheet FUJITSU Thin Client FUTRO A300

JOFRACAL Temperature and Pressure Calibration Software

Magic Wand Portable Scanner

Additional Requirements for ARES-G2 / RSA-G2. One Ethernet 10 Base T/100 Base TX network card required for communication with the instrument.

CNC-STEP. "LaserProbe4500" 3D laser scanning system Instruction manual

Computer Creep System

Paint Test Equipment. Stargloss Gloss Meter Data Sheet

Hand-held thermometer Model CTH7000

10 Thomas, Irvine, CA USA Tel: (949) Fax: (949) Toll Free: (800) 23 FUTEK

1.44 kw Programmable DC Power Supplies XLN Series

User Manual of N280. Two cases are optional! N280 port schematic

Mitos P-Pump. product datasheet

22 (21.5 viewable) Smart Display, Full HD, Rockchip Quad-Core, Optical touch, Android KitKat. VSD224

500/600/1000. User Manual June 2011 Rev v061311

OdysseyTM. removable hard disk storage system. secure. fast. expandable.

Cisco Virtualization Experience Client 6215

How To Use Bodescan For 3D Imaging Of The Human Body

R60 USB to CAN interface Manual (1.5 EN)

UV-Vis spectrophotometers

VICKERS HARDNESS TESTER. HBS HBW Kc

reflecta Super 8 Scanner

Multi-Range Programmable DC Power Supplies 9115 Series

Quick Start Guide. Digital Inverted Microscope. The Microscope Evolved.

FACTORY AUTOMATION LGS SERIES INTELLIGENT

Providing reliable document management solutions for any budget is how we re engineering a better world. KV-S1026C SOLUTIONS FOR BUSINESS

USB 2.0 VGA ADAPTER USER MANUAL

PT-LB55NT S P E C F I L E. Micro-Portable Wireless LCD Projector. As of February Specifications subject to change without notice.

Product Information Sheet UH36 Hi Pot Tester

KIP EXCEPTIONAL MULTIFUNCTION VALUE

SIMATIC HMI IPC 477C 1/5. Copyright Siemens AG 2013

Preparing the Windows version of the software for use

1. Open the battery compartment as shown in the image.

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Measurement & Analytics Measurement made easy

Data Sheet ESPRIMO P1500. The wide-ranging home office and multimedia PC ESPRIMO P1500

Basic Specifications. Electrical. EPSON Perfection Color EPSON MatrixCCD TM line sensor. device Effective pixels

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

AXIS 262+ Network Video Recorder

For the latest information, check the product home page ( en/products/rack2_smart).

HP Scanjet G4000 series. User Guide

VWR SPECTROPHOTOMETERS

High Resolution Media Display - B series 20mm Pitch Outdoor RGB Module

ActiView. Visual Presenter Image Software User Manual - English

Pocket Tach 99 (PT99) Non-Contact Tachometer

VisiSens AnalytiCal 2 Software

How do I monitor the ink levels on my EPSON Stylus printer using Windows 2000 or XP?

Controlers. Controler

DWH-1B. with a security system that keeps you in touch with what matters most

How To Use An Ipad With A Microsoft Powerbook 2 (I2) And A Microtower (I3) For A Long Time (For A Small Family) (For Business) (I5) (Microtower) (Mini

Description: Multiparameter System (4 or 8 channels)

140 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

Network analyzer and spectrum analyzer two in one

GV-Hot Swap Backup Center System (Rev. B) 3U, 16 / 8-Bay

3D MultiVision SOFTWARE OPERATING INSTRUCTIONS

MB3600 Versatile FT-NIR analyzer designed for your industry The most reliable FT-NIR specifically designed for QA/QC

9.7" Microscope Tablet Camera (REALPAD 5.5) Introduction. Feature

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

VENTIsupport Version 1

The new 5.7 standard model

Data Sheet Fujitsu FUTRO A300 Thin Client

Temperature Datalogger Users Manual

Technical summary X-LED MESH X-LED - Made by Carl Stahl

Volume Measurement. TexVol BVM-L Series. Accurate Volume in seconds

1. SAFETY INFORMATION

Data Sheet Fujitsu LIFEBOOK A512 Notebook

Alignment Laser System.

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

USER PROGRAMMABLE AUTHORIZE USERS AT THE CLICK OF A MOUSE AUDIT TRAIL AND TIME ZONE CONTROL LOCK SYSTEM MANAGEMENT SOFTWARE:

6AV3617-1JC30-0AX1. Type of voltage. UPS connectable (serial) Backup battery. minimum backup duration Memory. Flash / RAM.

Wirbelstrom Prüfsysteme. eddyliner. digital

MedInformatix System Requirements

Unmatched Metal Hardness Testing

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

User Manual. Software SmartGUI. Dallmeier electronic GmbH & Co.KG. DK GB / Rev /

Software for network-based video recording system SISTORE MX NVR (Ver. 2.57)

Transcription:

haze-gard i The objective standard for a clear view Transparent products can have a milky or fuzzy appearance dependent on its light scattering behaviour. The haze-gard i quantifies the visual perception with objective measurement criteria: Total transmittance Transmission haze Clarity haze-gard i controls complete transparency by taking only one reading. Global communication Haze and transmittance control according to international standard methods with one unit: ASTM D1003 - illuminants C and A Non-compensated method ISO 13468 - illuminant D65 Compensated method haze-gard i displays all results simultaneously - well prepared for any customer specification. Reliable and Precise With state-of-the-art optics and LED technology the haze-gard i delivers an unprecedented performance: Reference beam, self-diagnosis and enclosed optics. LED light source assures long-term stable results for many years: 10 year warranty on the lamp life! Automatic, long-term calibration - operator friendly and safe. REF Superior repeatability and inter-instrument agreement are guaranteed.

Smart and Fast The new touch display is designed to be intuitive and easy to use for any task: Large touch display in color. Symbols to select a menu function. Dedicated measurement button. Footswitch allows hands-free operation. Open and Flexible The open measurement compartment let s you work freely to analyze any sample size: Open design for small and large specimens. Fast change and positioning of samples. No influence of ambient light. Versatile sample holder for films and sheets. Sample holders for taber abrasion test and cuvettes for liquids optional. Customized sample holders can be easily attached. Horizontal or vertical set-up Sample handling in any position is convenient and allows you highest flexibility.

Onboard analysis Measurement data can be analyzed and saved in projects directly in the haze-gard i for efficient work management: Large instrument memory (5000 readings). Complete statistics with averaging, min / max, standard deviation. Limit input for different product specifications with colorful Pass/Fail analysis. Professional connection Data transfer can be performed in all sorts of ways to support you in routine lab work: Direct data transfer via USB-port to PC. Direct LAN connection to your network for further analysis in Laboratory Information Management Systems (LIMS). Save data on a USB-stick. smart-lab haze - data analysis software Whatever the task, smart-lab haze will do it for you. From simple data tables of single test series to trend reports over time - anything is possible. Define your product specifications in standard management by setting up product groups with Pass/Fail limits. Measure your products online and get instant QC reports displayed: Data table with statistic and line graph including Pass/Fail coloring. Manage your lab work in projects to show production process stability using trend reports. Transfer product specs and projects to haze-gard i and vice versa for daily work management.

In compliance with: Standards ASTM D1003, D1044 ISO 13468, 14782 Ordering Information Technical Specifications Cat. No. Description 4775 haze-gard i Illuminants CIE-C, CIE-A (ASTM D1003) Comes complete with: Hazemeter with sample holder Clarity calibration standard Traceable certificate Foot switch and power cord USB-cable and LAN-cable smart-lab haze software on CD with License Key (2 licenses) Operating manual Training Extended Warranty: see pages about Technical Service Free 1x preventive maintenance service during warranty period Note: smart-chart licence fee for more than two installations is quantity dependent. Please contact your local BYK-Gardner representative. System requirements: Operating system: Windows 7 SP1 or 8.1 Microsoft.NET Framework 4 Hardware: Core 2 Duo, 2.2 GHz, i7 recommendet, or equivalent Memory: 4 GB RAM, 8 GB recommendet Hard-disk capacity: min. 300 MB Monitor resolution: 1280 x 1024 pixel or higher Disk drive: CD-ROM or DVD drive Interface: free USB-port or network access Spectral Response Geometry Measurement Area Sample Port CIE-D65 (ISO 13468, ISO 14782) CIE luminosity function y 0 / diffuse ø 18 mm (0.7 in) ø 25.4 mm (1.0 in) Measurement Range 0 100 % Repeatability Reproducibility Memory Interface Power Supply Operating Temperature Storage Temperature Dimensions Weight ± 0.1 units (standard deviation) ± 0.4 units (standard deviation) 5000 readings LAN, USB 2.0, additional front USBport for memory stick 115/230V self adapting +10 to 40 C (+50 to 104 F) 0 to 50 C (+32 to 122 F) 62 x 33 x 22 cm (24 x 13 x 9 in) 18 kg (40 lbs) Training BYK-Gardner offers you more than just an instrument. We train you in the operation of the haze-gard i and data analysis. A half-day training course for haze-gard i operation and smart-lab haze software is included.

Versatile sample holders for specific needs Easy replacement of holders for different applications. Special holder for very thin films Ordering Information Accessories Cat. No. Description 4784 Thin Film Holder, for 4775 Special holder for very thin films 4785 Taber Abrasion Holder, for 4775 For evaluation of abrasion resistance with the hazemeter 4786 Cuvette Table, for 4775 For measurement of liquids 6180 Cuvette for Liquids, 2.5 mm Path length 2.5 mm, edge length 50 mm 6182 Cuvette for Liquids, 5 mm Path length 5 mm, edge length 50 mm 6183 Cuvette for Liquids, 10 mm Path length 10 mm, edge length 50 mm 6189 Cuvette for Liquids, 20 mm Path length 20 mm, edge length 50 mm 4865 BYKWARE smart-lab haze Software for professional analysis and documentation Space Holder Space Holder The measurement of haze is used to determine abrasion resistance of transparent materials. The haze-gard i Abrasion Holder facilitates positioning of the abraded area in the measurement beam. Liquids are best measured using cuvettes and the cuvette table.

Please refer to section Preventive Maintenance Ordering Information Accessories Cat. No. Description 4776 Clarity Calibration Standard, for 4775 Replacement Standard for clarity, certificate included 4777 Clarity Reference Standard, for 4775 Test standard for checking purposes, certificate included 4790 Haze Standard 1, for 4775 Approx. 1% haze, for checking purposes, certificate included 4791 Haze Standard 5, for 4775 Approx. 5% haze, for checking purposes, certificate included 4792 Haze Standard 10, for 4775 Approx. 10% haze, for checking purposes, certificate included 4793 Haze Standard 20, for 4775 Approx. 20% haze, for checking purposes, certificate included 4794 Haze Standard 30, for 4775 Approx. 30% haze, for checking purposes, certificate included 4795 Haze Standard Set, for 4775 Set of 5 pieces in hard box, certificate included 4778 Transmittance Standard 10, for 4775 Approx. 10% total transmittance, for checking purposes, certificate included 4779 Transmittance Standard 30, for 4775 Approx. 30% total transmittance, for checking purposes, certificate included 4780 Transmittance Standard 50, for 4775 Approx. 50% total transmittance, for checking purposes, certificate included 4781 Transmittance Standard 70, for 4775 Approx. 70% total transmittance, for checking purposes, certificate included 4782 Transmittance Standard 90, for 4775 Approx. 90% total transmittance, for checking purposes, certificate included 4783 Transmittance Standard Set, for 4775 Set of 5 pieces in hard box, certificate included