District 4 Deployment Report



Similar documents
Statewide Transportation Management Center Software Library System

Release 6.0.0p3 Installation Notes

Software Integration Plan

SunGuide Software. Color Dynamic Message Sign Support Concept of Operations. Technical Memorandum. Version 1.0. February 24, 2012.

DOCUMENT CONTROL PANEL

DOCUMENT CONTROL PANEL

QUALITY TRAFFIC INFORMATION

EXHIBIT A SunGuide Software Support, Maintenance, and Development. Scope of Services. Table of Contents

Session 32 Liang Hsia. Certification Program for Signal and Intelligent Transportation Systems (ITS) devices

Database Licensing Analysis

Using High Availability Technologies Lesson 12

Notification messages

System i and System p. Customer service, support, and troubleshooting

10/27/2009 Change Management Board

Traffic Management Centers for the Extreme Do-It-Yourselfer

Job Aid: Manual Backup Servers for S8500 or S8700 Media Servers R2.0 or later

Installing an Omnicast System Omnicast version 3.5

Packet Tracer - Connecting a Wired and Wireless LAN Topology

Customized Cloud Solution

Automation Engine 14. Troubleshooting

Change Management Board. Document Title

John Ragan Director of Product Management. Billy Wise Communications Specialist

Technical Brief. DualNet with Teaming Advanced Networking. October 2006 TB _v02

Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide

Contents UNIFIED COMPUTING DATA SHEET. Virtual Data Centre Support.

USER S MANUAL. AXIS Mobile Monitor

ProSafe Plus Switch Utility

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

1 PC to WX64 direction connection with crossover cable or hub/switch

Web Security Log Server Error Reference

1.3. The network element must have the ability to be configured in a point to point, point to multi point, and daisy chain configuration.

Guide for Updating Firmware and Troubleshooting Connection Issues

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

Networking. General networking. Networking overview. Common home network configurations. Wired network example. Wireless network examples

HP Intelligent Management Center v7.1 Virtualization Monitor Administrator Guide

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

Product Overview. Steve Erickson

ADDRESSING BANDWIDTH CONSTRAINTS IN THE HOSPITALITY AND SPECIALTY RETAIL INDUSTRIES

Three Key Design Considerations of IP Video Surveillance Systems

SAN Conceptual and Design Basics

Appendix A - Cost Estimate Spreadsheet

Internet Filtering Appliance. User s Guide VERSION 1.2

Log Server Error Reference for Web Protection Solutions

A Guide to Simple IP Camera Deployment Using ZyXEL Bandwidth Solutions

Vertical Phone System Upgrades Scope of Work

Prisma II Software Upgrade Program (SOUP) Installation Guide

1 Serial RS232 to Ethernet Adapter Installation Guide

Universal Network Access Policy

Security & Surveillance Cabling Systems

Using the ClearSight Analyzer To Troubleshoot the Top Five VoIP Problems And Troubleshooting Streaming Video

Chapter 15: Advanced Networks

Backup Exec 9.1 for Windows Servers. SAN Shared Storage Option

FMAudit Local Agent Deployment Expectation Settings to Prepare Your Client IT Departments

Moxa Device Manager 2.0 User s Guide

DSX Master Communications

Global Monitoring + Support

ONSITE TESTING TROUBLESHOOTING GUIDE

MDM Mass Configuration Tool User s Manual

Exam: QUESTION 1 QUESTION 2 QUESTION 3 QUESTION 4

Optimized Network Monitoring

Smart wayside management software

integrated lights-out in the ProLiant BL p-class system

Best Practices for Integrating NetVanta UC Server with Microsoft Exchange Server

ebus Player Quick Start Guide

White Paper: PostgreSQL and SunGuide Software Cloud Analysis. PostgreSQL

General system requirements

AVG Business SSO Connecting to Active Directory

Observer Analysis Advantages

AXIS 205 Network Camera Goes anywhere your network goes

BELNET: Service Level Description Version (29/7/2009)

Technicolor ATSC-8. User s Guide Technicolor. All Rights reserved

Data Link Protocols. TCP/IP Suite and OSI Reference Model

Digi International: Digi One IA RealPort Latency Performance Testing

Troubleshooting VoIP and Streaming Video Problems

COMPLEX SYSTEMS ONE SOLUTION

DVBLink For IPTV. Installation and configuration manual

How To Run A Hosted Physical Server On A Server At Redcentric

Installing The SysAidTM Server Locally

FioranoMQ 9. High Availability Guide

Docufide Client Installation Guide for Windows

DataWorX32 Professional Getting Started with Redundancy

StruxureWare Data Center Operation Troubleshooting Guide

An Introduction to VoIP Protocols

IBM FileNet Image Services

HL2170W Windows Network Connection Repair Instructions

SmartPTT File Transfer User's Guide. Version 2.0

TP-LINK TD-W8901G. Wireless Modem Router. Advanced Troubleshooting Guide

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

Eastern RTMC.

How To Install An Org Vm Server On A Virtual Box On An Ubuntu (Orchestra) On A Windows Box On A Microsoft Zephyrus (Orroster) 2.5 (Orner)

OCS Training Workshop LAB14. Setup

Installation Guide v1.11 and Higher

CT LANforge-FIRE VoIP Call Generator

Providing Patch Management With N-central. Version 7.2

ProSAFE 8-Port and 16-Port Gigabit Click Switch

For version p (September 4, 2012)

Panorama High Availability

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

Communication Protocol

Transcription:

SunGuide SM : District 4 Deployment Report Prepared for: Florida Department of Transportation Traffic Engineering and Operations Office 605 Suwannee Street, M.S. 90 Tallahassee, Florida 32399-0450 (850) 410-5600 June 23, 2005

Document Control Panel File Name: File Location: CDRL: Created By: Reviewed By:.doc SunGuide CM Repository n/a Name Initial Date Steve Dellenback, SwRI SWD 06/20/05 Robert Heller, SwRI RWH 06/20/05 Steve Dellenback, SwRI SWD 06/23/05 Modified By: Completed By: i

Table of Contents Page List of Acronyms... iii Revision History... iv 1. Scope... 1 1.1 Document Identification... 1 1.2 Installation Objectives... 1 1.3 Document Overview... 1 2. Installation Activities... 2 2.1 Daily Activities... 2 2.1.1 Day One (Monday June 13, 2005)...2 2.1.2 Day Two (Tuesday June 14, 2005)...3 2.1.3 Day Three (Wednesday June 15, 2005)...3 2.1.4 Day Four (Thursday June 16, 2005)...4 2.1.5 Day Five (Friday June 17, 2005)...5 2.1.6 Week Two (Monday June 20 Wednesday June 22, 2005)...5 2.2 Issues Identified... 6 ii

List of Acronyms CCTV...Closed Circuit Television COTS...Commercial-Off-The-Shelf DMS...Dynamic Message Sign DR...Deployment Report FDOT...Florida Department of Transportation GUI...Graphical User Interface IM...Incident Management IP...Implementation Plan ITS...Intelligent Transportation Systems MCP...Manual Control Panel MDX...Miami-Dade Expressway Authority STR...Software Test Report SwRI...Southwest Research Institute TMC...Transportation Management Center TSS...Transportation Sensor Subsystem VDD...Version Description Document VS...Video Switch VW...Video Wall iii

REVISION HISTORY Revision Date Changes 1.0.0 June 23, 2005 Initial Release. iv

1. Scope 1.1 Document Identification This document serves as the Deployment Report (DR) for the SunGuide SM software Release 1.1 installed in District 4 June 13, 2005 to June 17, 2005. 1.2 Installation Objectives A detailed Implementation Plan (IP) was provided to FDOT prior to deployment in Distirict 4. This document identified the expected preconditions as well as what activities would be performed by the deployment team. The following SunGuide SM subsystems were to be installed for the initial deployment at District 4: Administrative Editor Executive Handler Status Logger Data Bus GUI / Map (GUI) Closed Circuit Television (CCTV) Dynamic Message Sign (DMS) Video Switching (VS) Video Wall (VW) Transportation Sensor Subsystem (TSS) Incident Management (IM) The installation of the Commercial-Off-The-Shelf (COTS) software was to be the responsibility of the FDOT. The software required is detailed in the IP and the SunGuide SM Version Description Document (VDD). 1.3 Document Overview The remainder of this document provides the following: Discussion of the day-to-day activties Issues identified during installation

2. Installation Activities The following sections describe the activities and results of the installation activities that were performed. 2.1 Daily Activities The following is a narrative discussion of the tests and their results. 2.1.1 Day One (Monday June 13, 2005) SunGuide SM Release 1.1 software installation: District 4 intended SwRI to install the SunGuide SM Release 1.1 software into a Microsoft Windows 2003 Server Enterprise Edition Cluster environment. There were three pairs of servers, each pair formed a cluster. Two of the clusters were for SunGuide SM software, the third pair for Oracle. A SAN resident logical volume was created, formatted and mounted as the S: drive on the cluster SG-STATUS-LOGGER. A folder SunGuide was created in the root directory of S and made into a share point. Another directory was created for storing files from status logger. At the request of SwRI personnel, the second server in each cluster was powered off so that the initial installation would be not in a cluster but in a non-clustered Windows server environment. The config.xml file was moved into the SunGuide share with other configuration files (XML schema directory, devicesequence.xml file). The SunGuide SM software installation on SAMPLE and SUNRISE. The installations seemed successful, the installer was able to access the SunGuide share. The NETWORK SERVICE account (used by all the services) was not able to access the SunGuide share across the network. When the services were run as the Doman Administrator, they were able to access the share. Unable to resolve the problem with permissions, a temporary second SunGuide share was created on Sunrise and populated with duplicate data. This allowed the services to be run as NETWORK SHARE user. The system was started with access to the database on the SwRI laptop. Installation of Oracle 10g with RAC: Oracle Cluster Ready Services was installed on the two servers in the group SG-DB- ORACLE. Oracle Enterprise was installed on the RAC. A SunGuide SM database (SGD4) was created and populated with basic data including roadways, cross streets and DMSs. The deployment team decided to not fight potential problems with the database and to continue running against the laptop. Barco API Installation: SwRI personnel in a teleconference with Barco installed the Barco Apollo API on the District 4 wall controller.

2.1.2 Day Two (Tuesday June 14, 2005) CCTV: Continued testing with the CCTV driver to establish connectivity to the VBrick Encoder / port server; this testing was unsuccessful. District 4 is using the VBrick encoder as a port server. SwRI was not able to successfully connect to the camera controls in this manner. The only way that the cameras have been demonstrated in this manner is to slave the encoder to a decoder and pass serial data through the pair. Dellenback and Farmer were to test the configuration Wednesday AM in the SwRI labs. Video switching: SwRI established the ability to control decoders in the server room to successfully decode VBrick streams coming into the server room. These are being displayed on a monitor within one of the server racks. Video wall control: SwRI reinstalled a later version of the Barco Apollo API that was furnished by District 4 (after installing an earlier version supplied by SwRI on Monday). It was decided to install this later version since it was a released version instead of a Beta version supplied via download to SwRI. Tested successfully. The SunGuide SM software can retrieve layouts, change layouts, and switch inputs around including input streams from cameras and the D6 stream (among others. SwRI personnel configured the inputs into the District 4 TMC in the Barco Wall controller database to allow switching of those inputs. DMS control: District 4 provided a Digi device that had not been configured nor installed in their system for SwRI use. SwRI was unable to configure the Digi device and instead installed an SwRI owned device for testing. Configuration of all District 4 devices was completed in the SwRI laptop database. Initial testing with a modem connected sign failed. Later SwRI was to learn this was because of a bad modem in one of the server racks (it was unmarked and power was available to it). TSS sensors: SwRI was able to establish connectivity to the Wavetronix sensor in the field with the SwRI test program. At days end SwRI was still not able to retrieve data from the Wavetronix sensor in the field using the RTMS driver. 2.1.3 Day Three (Wednesday June 15, 2005) CCTV: SwRI successfully demonstrated use of a VBrick encoder as a port server in SwRI labs. SwRI found that the VBrick encoder would not accept a connection from the CCTV driver if a VBrick decoder was also trying to run in pass through mode. When the

VBrick decoder in the District 4 server rack was no longer in pass through mode, the VBrick encoder accepted the connection and PTZ control was exercised for cameras 26 and 29 along I-95. Video switching: SwRI renamed the video sources (VBrick encoders) to lead with a numeric field (this so that video switching can be accomplished using MCPs when they are available). This caused the video sources to become disassociated from cameras within the SunGuide SM database and loss of video switching capability. Once the association was reestablished within the database VS was reestablished. DMS control: District 4 provided a access to the I-595 loop of cameras and one IP connected camera during the 10 AM to 2 PM time slot. SwRI successfully demonstrated the ability to display messages on the serial connected signs (IP to Digi / serial to fiber modem / fiber to field device / serial to sign). SwRI demonstrated the capability to display messages to a group of signs (all on I-595) within a matter of seconds. SwRI was unable to place a message on the IP connected sign. It was decided to bring a controller into the server room where the suspected cabling issues could be resolved. The controller was to be provided on Thursday. TSS sensors: During analysis of the communications between the sensor and the RTMS driver SwRI discovered that the sensor (Moxa port server) was sending data to the RTMS driver in very small packets (4-6 bytes). These were causing the 250+ byte message to time out within the RTMS driver. When the time out limit was raised, communications were successfully established. The operator map successfully displayed TSS sensor data being retrieved from the field. 2.1.4 Day Four (Thursday June 16, 2005) Oracle Fail Safe installation: District 4 decided to uninstall the Oracle RAC database (due to lack of licensing) and install Oracle Fail Safe as recommended by FDOT Tallahassee. The installer ran unsuccessfully until a conference call with Mike Novak. After the conference call and some Oracle Fail Safe installation cleanup, Oracle Fail Safe, Oracle Enterprise Server 10g, and the District 4 SunGuide SM database was successfully installed and running on the District 4 SG-DB-ORACLE windows cluster. CCTV: Two more CCTVs were configured for NTCIP, the cameras were added to the database using the SunGuide SM administrative editor and ability to control the cameras was verified. DMS control: DMS via IP connected Moxa port server: District 4 provided a controller and Moxa into the server room. The team tried a variety of cable combinations between the Moxa and

the controller; no combination seemed to help. SwRI successfully communicated to the controller using a serial cable and verified the controller is operational. SwRI found out the SwRI sign has Firmware 2.9 (or close to this) and District 4 has 2.4 (or close to this). SwRI and District 4 have spent a lot of time on this one controller (and can talk to 20+ signs trouble free.) SwRI was able to configure the District 4 supplied Digi controller after discussion with Network support staff at SwRI. That Digi was substituted for the SwRI supplied Digi. District 4 provided access to the I-95 ring for a period of time after 2:00 PM. The SunGuide SM DMS subsystem / driver talked to a vast majority of the signs (not all were in the database.) TSS sensors: TSS data is being displayed on the Operator Map. A patch was developed and installed on the District 4 servers. 2.1.5 Day Five (Friday June 17, 2005) Oracle Fail Safe Database installation: The District 4 SunGuide SM servers were reconfigured to access the Oracle Fail Safe Database. After some initial problems were corrected in the database, some of the subsystems worked, some continued to have problems. These were not immediately resolved and a transition was made back to the SwRI laptop database to facilitate additional sign testing between 10 AM and 2 PM. DMS: The Moxa had been configured with a timeout value of 0 milliseconds for the transmit buffer this causes the Moxa to send out a couple of bytes (using an entire Ethernet packet) rather than waiting until a full buffer of data was received this caused problems in the DMS drive. Using this setting will cause network saturation when a District has a large number of devices. The SwRI & District 4 team changed the setting to 600 milliseconds and the sign and SunGuide SM software communicate. District 4 needs to move the device to the field for a complete test but all (including D4) expect no problem with this. TSS: The TSS Moxa box has the same setting which SwRI believes is causing the behavior noted on Day 3; it is highly likely that if this setting was set to 500 milliseconds the code change would not have been necessary. 2.1.6 Week Two (Monday June 20 Wednesday June 22, 2005) During the subsequent week, on-site SwRI personnel worked with District 4 personnel to establish the high availability system that District 4 wanted. The SunGuide SM services are running on Windows 2003 Enterprise Server in two clusters. The database is running on Oracle cluster Fail Safe configuration.

2.2 Issues Identified The following is a list of the issues identified during the deployment: Operating System: District 4 directed SwRI to install the SunGuide SM software on a Microsoft Windows Cluster. This operating system was not in the SunGuide SM requirements and no testing of the software has occurred on this platform. SwRI recommends that the SunGuide SM requirements be updated and testing performed with Windows Cluster. Database: FDOT did not purchase Oracle RAC licenses, but is licensed to run Oracle Fail Safe. SwRI recommends that the SunGuide SM requirements be updated and testing performed with Oracle Fail Save.