Eaton NetWatch v5.0 NetWatch on Microsoft Hyper-V server 2008 Installation and configuration guide



Similar documents
Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Eaton NetWatch NetWatch installation and configuration guide VMware ESX 3 Virtual architecture

Citrix XenServer 5.6 OpenSource Xen 2.6 on RHEL 5 OpenSource Xen 3.2 on Debian 5.0(Lenny)

Network Shutdown Module V3 Extension of the User Manual for IBM BladeCenter architecture

Netwatch Installation For Windows

Integrating Eaton PRO Management Pack for Microsoft System Center Virtual Machine Manager 2008 v1.0 Page 2

Using Intelligent Power Manager (IPM) & Intelligent Power Protector (IPP) on Virtual Desktop Infrastructure (VDI)

PANO MANAGER CONNECTOR FOR SCVMM& HYPER-V

How to Restore a Windows System to Bare Metal

Installation and Configuration User's Guide

Acronis Backup & Recovery 10 Workstation. Installation Guide

Microsoft Windows Server 2008: MS-6422 Implementing and Managing Hyper V Virtualization 6422

Pearl Echo Installation Checklist

Dell UPS Local Node Manager. User Guide. Dell.com

Backup & Disaster Recovery Appliance User Guide

Windows Server 2008 R2 Hyper V. Public FAQ

Table of Contents. FleetSoft Installation Guide

Networking Best Practices Guide. Version 6.5

NETWRIX IDENTITY MANAGEMENT SUITE

ACTi NVR Config Converter User s Manual. Version /06/07

To get started, you will need the following items Product Key Router with firewall capability Network cables

HP RDX Continuous Data Protection Software Quickstart Guide

Microsoft Windows Built-In Serial and USB UPS Support

Universal Management Service 2015

Verax Service Desk Installation Guide for UNIX and Windows

Kaseya 2. User Guide. Version R8. English

PowerChute Network Shutdown v4.1 Release Notes

Release Notes: PowerChute plus for Windows 95 and Windows 98

Eaton Intelligent Power Protector User s Guide / AI Eaton Intelligent Power Protector User s Guide

SQL Server 2005 Express Installation guide

HP Thin Client Imaging Tool

SAM 8.0 Backup and Restore Guide. SafeNet Integration Guide

Real-time Protection for Hyper-V

DSView 4 Management Software Transition Technical Bulletin

CONFIGURING MICROSOFT SQL SERVER REPORTING SERVICES

Acronis Backup & Recovery 10 Server for Windows. Installation Guide

How To Set Up Power Supply On Windows (Windows) With Powerup (Windows 8) On Windows 7.1) On A Pc Or Windows 8 (Windows 7) On An Ipad Or Ipad (Windows Xp

Nexio Connectus with Nexio G-Scribe

Server-Virtualisierung mit Windows Server Hyper-V und System Center MOC 20409

Sage Grant Management System Requirements

Jetico Central Manager. Administrator Guide

Deploying Windows Streaming Media Servers NLB Cluster and metasan

Using IPM with VMware s Site Recovery Manager

StruxureWare Data Center Expert Release Notes

Network/Floating License Installation Instructions

GFI Product Manual. Deployment Guide

Q A F 0 3. ger A n A m client dell dell client manager 3.0 FAQ

Virtual Desktop Infrastructure in

Before deploying SiteAudit it is recommended to review the information below. This will ensure efficient installation and operation of SiteAudit.

Product comparison. GFI LanGuard 2014 vs. Microsoft Windows Server Update Services 3.0 SP2

How to Configure Windows Firewall on a Single Computer

Install SQL Server 2014 Express Edition

How to install software on VMware ESXi 4.0/4.1

XenClient Enterprise Synchronizer Installation Guide

HOW TO SILENTLY INSTALL CLOUD LINK REMOTELY WITHOUT SUPERVISION

Course Syllabus. Implementing and Managing Windows Server 2008 Hyper-V. Key Data. Audience. At Course Completion. Prerequisites

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

DCA Local Print Agent Push Install

Running 4D Server as a Service on Windows

7.x Upgrade Instructions Software Pursuits, Inc.

Kaspersky Endpoint Security 10 for Windows. Deployment guide

Managing Multi-Hypervisor Environments with vcenter Server

NETFORT LANGUARDIAN INSTALLING LANGUARDIAN ON MICROSOFT HYPER V

PARALLELS SERVER BARE METAL 5.0 README

Microsoft Windows 7 Ultimate 64 Bit SP1 Operating System Recovery Media for 300 GB Solid State Drives Instructions

VMware vsphere 5 Quick Start Guide

INSTALLING MICROSOFT SQL SERVER AND CONFIGURING REPORTING SERVICES

Installation Notes for Outpost Network Security (ONS) version 3.2

Secure Agent Quick Start for Windows

Ad Hoc Transfer Plug-in for Outlook Installation Guide

Software Update for WinXP

Microsoft Software Update Services and Managed Symantec Anti-virus. Michael Satut TSS/Crown IT Support

Windows 7. Tips and Tricks. Scott Sekinger

Overview of ServerView Windows Agent This chapter explains overview of ServerView Windows Agent, and system requirements.

SyAM Software, Inc. Server Monitor Desktop Monitor Notebook Monitor V3.2 Local System Management Software User Manual

MS-6422A - Implement and Manage Microsoft Windows Server Hyper-V

Windows Server 2008 Hyper-V, Windows Server 2008 Server Core Installation Notes

Windows Host Utilities Installation and Setup Guide

6422: Implementing and Managing Windows Server 2008 Hyper-V (3 Days)

NETWRIX EVENT LOG MANAGER

Pre-Installation Checks Installation Creating Users and Quick Setup Usage Examples and Settings Appendix

StruxureWare Data Center Expert Release Notes

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

InventoryControl for use with QuoteWerks Quick Start Guide

SAM Backup and Restore Guide. SafeNet Integration Guide

TimeIPS Server. IPS256T Virtual Machine. Installation Guide

Synchronizer Installation

Dell Solutions Overview Guide for Microsoft Hyper-V

3. Where can I obtain the Service Pack 5 software?

UNIVERSAL NOVASCALE R421 R422 R422-INF. HOW TO: Replace the BIOS. REFERENCE Rev04v01

WD Sentinel DX4000. Small Office Storage Server. Administrator s Quick Install Guide

CCH Portal. Installation Guide. June 2013

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

End-User troubleshooting guide For Sentinel SuperPro/UltraPro and Sentinel Hardware Keys

Consolidated Monitoring, Analysis and Automated Remediation For Hybrid IT Infrastructures. Goliath Performance Monitor Installation Guide v11.

Sharp Remote Device Manager (SRDM) Server Software Setup Guide

Upgrading Client Security and Policy Manager in 4 easy steps

NETWRIX ACCOUNT LOCKOUT EXAMINER

Tripp Lite PowerAlert

Transcription:

Eaton NetWatch v5.0 NetWatch on Microsoft Hyper-V server 2008 Installation and configuration guide Hyper-V 6.0 NetWatch Main operating system: 2008 Enterprise x64 (hosting Hyper-V) Eaton UPS Eaton NetWatch on Microsoft Hyper-V installation guide February 4, 2009

Index 1 Introduction... 3 2 Installation... 4 2.1 Prerequisites... 4 2.1.1 Microsoft Hyper-V configuration... 4 2.1.2 Eaton hardware architecture... 5 2.1.3 Network architecture... 5 2.2 Installation... 6 3 Appendix... 8 3.1 References... 8 Eaton NetWatch on Microsoft Hyper-V installation guide Page 2/8

1 Introduction Eaton is a first-class supplier of hardware and software optimizing business continuity on your Microsoft virtual platforms worldwide. The systems include controlling proper boot and graceful shutdown of: Virtual machines hosted on the same physical machine. The main operating system hosting Microsoft Hyper-V. NetWatch is Eaton s solution to automate various data security functions. NetWatch clients are able to shutdown a server or workstation under the control of a UPS. It: Continuously waits for information from the ConnectUPS Web/SNMP card or Network Management Card (NMC) connected to the Eaton UPS. Warns administrators and users if AC power fails. Proceeds to shutdown system before the end of battery backup power is reached. Automatic startup on power restore option is machine dependent. It will work when machine bios is set to support it. To do that, changes need to made in bios to start the computer when power is provided. Microsoft Hyper-V controls the Virtual Machine s shutdown and restart functions. Version 5 of Eaton s NetWatch can be installed on the main operating system (hosting Hyper-V). NetWatch will manage electrical redundancy, consolidating information from the UPSs that are supplying the server. Advantages of installing our protection software on the main operating system (hosting Hyper-V) include: Only one deployment of NetWatch v5 on a physical machine, to manage all virtual machines. Dynamic management of virtual machines configuration, with a personalized script. This manual will guide you through the installation and configuration process of NetWatch on the Microsoft Hyper-V platform. Eaton tested virtualization security in a UPS power supply backup configuration, for system shutdown, electrical shutdown and reboot. Eaton NetWatch on Microsoft Hyper-V installation guide Page 3/8

2 Installation Section 2 guides the user through the installation process of NetWatch on Microsoft Hyper-V architecture. Use of NetWatch v5 will allow continuity of the electrical power supply to the end-user s internal power system. 2.1 Prerequisites This procedure was validated using Microsoft Windows 2008 Enterprise x64 as the main operating system (hosting Hyper-V). The system had the following applications installed: - Microsoft Hyper-V (hosting virtual machines running Microsoft Windows Vista, Microsoft Windows XP SP2, Suse Enterprise Linux 10) - NetWatch v5 for Windows 2.1.1 Microsoft Hyper-V configuration For the automatic OS boot on startup: the user must configure the physical machine to allow automatic OS boot on startup. This is found in the machine s BIOS. For further information, see specific documentation of the physical hardware. Note: It may be required to activate Virtualization Technology Enabled (in the machine s BIOS) to run Hyper-: CPU Information -> Virtualization Technology -> Enabled To ensure an automatic boot of each virtual machine when Microsoft Hyper-V starts-up, use the following procedure: > From the Hyper-V manager: - Select the virtual Machine list, then the Virtual Machine - Select Parameters -> Manage -> Automatic Start Action - Choose the appropriate parameters for the virtual machine that coincide with the start rules of the specific application. This configuration is illustrated on the following screenshot: Eaton NetWatch on Microsoft Hyper-V installation guide Page 4/8

Follow this procedure to ensure an automatic graceful shutdown of each virtual machine when Microsoft Hyper-V stops: > From the Hyper-V manager: - select the virtual Machine list, then the Virtual Machine - select Parameters -> Management -> Automatic Stop Actions, - choose the appropriate parameters for the virtual machine, to fit with shutdown rules of the specific application, This configuration is illustrated on the following screenshot: 2.1.2 Eaton hardware architecture The UPS system s compatibility can be found at Eaton s Web site (http://www.powerware.com/software/downloads.asp) 2.1.3 Network architecture All hardware elements must have an operational network configuration that allows free dialog amongst each other. Connections through the following ports must be authorized within the firewall of the main operating system: For SNMP cards o Connections on UDP port 200, 2844 and 2844 to enable a remote access for supervision and configuration. For NMC Cards o Connections on UDP port 4679 and 4680 to enable a remote access for supervision and configuration. These ports are reserved at IANA (http://www.iana.org). To configure network parameters of the main operating system, please refer to its user manual. Eaton NetWatch on Microsoft Hyper-V installation guide Page 5/8

2.2 Installation Use the following procedure to install NetWatch v5: Download the latest version of NetWatch v5 Windows version package from Eaton s Web site http://www.powerware.com/software/downloads.asp Execute the package on the main operating system (i.e. Microsoft Windows 2008 Server). For more information, please refer to NetWatch v5 manual. The NetWatch v5 interface will look like: Select the load segment of the UPS to which the system is attached Select the Configuration Options tab Eaton NetWatch on Microsoft Hyper-V installation guide Page 6/8

Change the configuration option to shutdown and notification, and click on Apply to save the configuration. For more information about NetWatch configuration please refer to the NetWatch user document. Eaton NetWatch on Microsoft Hyper-V installation guide Page 7/8

3 Appendix 3.1 References «Eaton NetWatch v5 user manual» : downloadable from: http://www.powerware.com/software/netwatch_v5_info.asp?cx=36 For supported UPS and management cards, please refer release note document available at: http://www.powerware.com/software/netwatch_v5_info.asp?cx=36 References documents for Microsoft Hyper-V are available on: http://www.microsoft.com/windowsserver2008/en/us/hyperv.aspx Eaton is a trade name, trademark and/or service mark of Eaton Corporation or its subsidiaries and affiliates. All other trademarks are property of their respective owners. Microsoft, Windows and Hyper-V are trademarks of Microsoft Corporation. Eaton NetWatch on Microsoft Hyper-V installation guide Page 8/8