Annex 15-A: W. Edwards Deming 14 Points for Quality



Similar documents
Appendix A: Deming s 14 Points for Management

Lean Strategies Used to Optimize Automation. Why Lean Six Sigma? Laboratory Goals. Decreased TAT. Accurate Results. LEAN Goals.

Using the Lean Model for Performance Improvement

Sutter Health Support Services Shared Laboratory Position Description. Incumbent: Laboratory Date: October 23, 2006 Written By: Michele Leonard

LEAN 101 CRASH COURSE. Presented by Jacob McKenna and Seaver Woolfok

CHAPTER 13. Quality Control/Quality Assurance

Lean and Six Sigma Healthcare Fad or Reality. Vince D Mello President

TOPIC 8 QUALITY OBJECTIVE. Quality

Lean Thinking in Healthcare WESTERN STATES MEETING JUNE 26-27, 2014

BEGINNING THE LEAN IMPROVEMENT JOURNEY IN THE CLINICAL LABORATORY

LAP Audioconference How to Prepare and Comply with Your Quality Management Plan* February 18, 2009

BAPTIST HEALTH SCHOOL OF NURSING NSG 4027: PROFESSIONAL ROLES IN NURSING PRACTICE

2009 LAP Audioconference Series. How to Prepare and Comply with Your Quality Management Plan

Total Quality Management TQM Dr.-Ing. George Power. The Evolution of Quality Management

Laboratory Quality Metrics

Everything you want to know about ISO 15189:2012 Medical Laboratories Requirements for Quality and Competence

Content Sheet 10-1: Overview of External Quality Assessment (EQA)

Srikanth (Sri) Poranki, Ph.D., CSS-Black-Belt Director, Performance Improvement Dept. Quality & Patient Safety UHSH

Content Sheet 5-1: Overview of Sample Management

Sanford Improvement Making Lean Work in Healthcare

Overview of Lean at URMC

Introduction to Lean Healthcare

Norton Healthcare partners with Ortho Clinical Diagnostics to transform laboratory performance... for the long-term.

Office Efficiency Improving Office Processes and Task Analysis

times, lower costs, improved quality, and increased customer satisfaction. ABSTRACT

Lean Silver Certification Blueprint

The Future is Now. Global Application of CLSI and ISO:15189 Quality Management Systems. Glen Fine, MS, MBA

Lean Six-Sigma to Reduce Cycle Time and Inventory

7/17/2012. Welcome! Topic: Lean Six Sigma How Can it Help Your CSSD? Facilitators: Diane Koch 3M Susan Flynn 3M

LEAN: 5s in Human Resources

Gap Analysis of ISO 15189:2012 and ISO 15189:2007 in the field of Medical Testing

- White Paper - The Deming Guide to Quality. Point One Create Constancy of Purpose for Improvement of Product and Service

Class Objectives. Total Quality Management. TQM Definitions. TQM Definitions. TQM Definitions. TQM Definitions. Basic concepts on TQM

JOINT COMMISSION INTERNATIONAL ACCREDITATION STANDARDS FOR. 2nd Edition

Introduction to Statistical Quality Control, 5 th edition. Douglas C. Montgomery Arizona State University

A LEAN SIX SIGMA APPROACH TO CONTINUOUS QUALITY IMPROVEMENT IN THE TEXAS NEWBORN SCREENING PROGRAM

QUALITY GURUS (part 1) Manuel Rincón, M.Sc. September 24th, 2004

Creating the Lean and Efficient Medical Practice

Terrigal Burn MD Lean Physician Champion Palo Alto Medical Foundation

Total Quality Management and Cost of Quality

Going Lean the ERP Way

Body of Knowledge for Six Sigma Green Belt

Re-Engineering Lean Care Management and Automation in a Value-Based World

Lean Agile Scrum Business Value Development and Delivery using Agility. Brenden McGlinchey Software Done Right, Inc.

Going Beyond Laboratory Automation: Do Less Accomplish More. Swedish Covenant Hospital

Comparisons of Quality Management Systems

1 Introduction to ISO 9001:2000

Chapter 3. Review Questions. 5. Summarize Deming s 14 Points. How does each point relate to the four components of Profound Knowledge?

ERP Meets Lean Management

A Tool Box for Healthcare Problem Solving

LEAN CERTIFICATION BODY OF KNOWLEDGE RUBRIC VERSION 3.0

Hessel Visser NCOI Les 6 A P 373. Operations Management, 7E: Chapter 14 en15

Getting Started with Lean Process Management

The Original Quality Gurus

New York State Department of Health Wadsworth Center Clinical Laboratory Reference System Clinical Laboratory Evaluation Program

Deming s 14 Points for TQM

AN AUDIT QUESTIONNAIRE THAT EXAMINES SPECIFICALLY THE MANAGEMENT OF TECHNICAL ACTIVITIES CLAUSES IN ISO 15189

Patient Safety and the Laboratory

Lean Manufacturing and Six Sigma

Waterloo Agile Lean P2P Group

Drive Quality: Get the Skinny on Lean

CASE STUDY. NHS Board. Contact. . Title. Category. Background/ context. NHS Tayside

Improving Service Level Performance - Phoenix Process Quality Management

An Introduction to LEAN

Operations Management and Lean Six Sigma. Presented by: David Muncaster Manager, CI and CSAT Staples Advantage Canada

Hospital Pneumatic Tube System Buyer s Guide Evaluating material transport partners that fit your needs

Laboratory Quality Management System

Quality Systems Frameworks. SE 350 Software Process & Product Quality 1

Lean thinking and Six sigma at the level of Clinical Service Delivery

Document and Record Control in a Hospital Clinical Laboratory

I. INTRODUCTION A. There are two aspects to an effective operating system: 1. Design 2. Control.

Louisiana Tech University Lean Manufacturing Courses

Deming s 14 Points for the Transformation of Management

Process Improvement: Integrating Lean Six Sigma Ergonomics

4/24/2015. Urgent, STAT, Super STAT, ASAP! Achieving timely lab testing for the Emergency Department. Learning Objectives.

Topic 12 Total Quality Management. From Control to Management. Deming s Fourteen Points for TQM

Lean Healthcare Online

MEDICAL LABORATORY TECHNICIAN COMPETENCY PROFILE

Measuring Patient Flow in Urgent Care

UCLA PATHOLOGY & LABORATORY MEDICINE QUALITY MANAGEMENT PLAN

SAMPLE. Accuracy in Patient and Sample Identification; Approved Guideline. This guideline describes the essential elements of systems and processes

ME2110. Lecture 14: Total Quality Management - TQM

Implementation of Lean Six Sigma Principles: Making Data Cleansing Lean

The Medical Microbiology Milestone Project

SAMPLE. Quality Management System: Development and Management of Laboratory Documents; Approved Guideline Sixth Edition

Chapter 3 02/18/1437. Foundations of Quality Management. Deming ( ) Leaders in the Quality Revolution

How Automating Our Lab Scheduling Boosted Productivity, Improved Morale and Gave Managers More Time to Manage

Implementing Automation after Making Lean Improvements

MINIMUM AUTOMOTIVE QUALITY MANAGEMENT SYSTEM REQUIREMENTS FOR SUB-TIER SUPPLIERS

Chapter 2: Quality Assurance and Legal Issues

Appendix O MANUFACTURING YOUTH APPRENTICESHIP PRODUCTION OPERATIONS MANAGEMENT PATHWAY PRODUCTION OPERATIONS MANAGEMENT (UNIT 8)

RECEPTIONIST TEAM LEADER

Quality Improvement Primers. Voice of the Customer

Unaccredited Point-of-Care Laboratory Testing Guideline for Physicians

Body of Knowledge for Six Sigma Lean Sensei

ATOMS A Laboratory Specimen Collection and Management System

Developing a Formidable Business / Continuous Improvement Methodology in Africa. By: Frederick O Popoola

Transcription:

Annex 15-A: W. Edwards Deming 14 Points for Quality 1. Create constancy of purpose for improvement. 2. Improve constantly and forever. 3. Adopt the new philosophy. 4. Cease dependence on mass inspection. 5. End the practice of awarding business on price alone. 6. Institute training. 7. Institute leadership. 8. Drive out fear. 9. Break down barriers between staff areas. 10. Eliminate slogans, exhortations, and targets. 11. Eliminate numerical quotas. 12. Remove barriers to pride in workmanship. 13. Institute a vigorous program of education and training. 14. Take action to accomplish transformation. 1

Annex 15-B: Using a Lean Systems Approach to Improve Time to Reporting of Positive Blood Cultures INTRODUCTION Leans Systems Approach (LSA) improves process by identifying each step, removing non-value added steps, and eliminating waste. The benefits of applying such principles include a more efficient and timely delivery of product. The time to reporting of microbiology results using traditional culture-based phenotypic methods is complicated by the dependence on the growth rate of organisms for both initial detection and subsequent identification, often considered the limiting factor to timely reporting. We were interested to use LSA in our laboratory to assess the impact on the time to reporting of results. The Microbiology laboratory at Vancouver General Hospital (VGH) is a full service regional laboratory. We receive 47,000 blood cultures annually, which are tested using the BACTEC 9240 blood cultures system. Given the importance of timely blood cultures results and the numbers of blood cultures performed in our laboratory, any potential improvements in blood cultures processing would have a high clinical impact. Preliminary review revealed a delay in turn around time from first notification of a positive culture to the finalized result. METHODS The steps of LSA were followed: 1) process selected, 2) problem statement and objectives developed, 3) team selected and trained, 4) baseline data obtained, and 5) changes implemented and evaluated during the run event. Blood culture time to reporting was selected for the project according to the following criteria: importance of results, probability of success, visibility of impact, attitude of staff (can vs. can t), and strength of leadership. The project scope was all positive blood cultures from receipt in the laboratory to final results reporting. Three technologists were dedicated to the project for three months, assisted by an operations director (project champion) and an outside consultant. Two months were spent studying blood cultures processing. The laboratory was cleaned, de-cluttered, and organized to achieve standardization and to decrease unnecessary waiting and motion. Process changes were introduced. The final month was spent to assess the impact of changes. Data collected pre- and postchanges were tabulated and reviewed. All Microbiology technologists and Medical Microbiologists had the opportunity to provide feedback. LSA principles and tools were followed. Key tools included: 5S (sort, store, shine, standardize, sustain), value stream mapping (capture details of process), eliminate/reduce waste (waiting, overproduction, rework, motion, processing, inventory, intellect, transportation), spaghetti diagrams (map motion), measure times (Cycle time-from beginning to completion, Queue time-wait time between processes, Lead Time-Cycle time and queue time.) PROBLEM STATEMENT In our laboratory, only 19% of positive blood cultures are finalized with identification and susceptibilities within 24 hours of first signal as a positive blood cultures. PROJECT SCOPE All positive blood cultures from receipt to final results reporting. Table 1: Work Flow for Pre-Analytic Processing of Blood cultures, Pre- and Post-LSA. Pre-LSA: Not Post-LSA: standardized Standardized 1. Blood cultures received in Laboratory Reception by Tube / Porter / Cooler. 2. Blood cultures sorted, NOT treated as STAT. 3. Random arrival and login of blood cultures in Microbiology. 4. Blood cultures loaded into BACTEC when convenient. 1. Blood cultures received in Laboratory Reception by Tube/ Porter/ Sweeper. 2. Blood cultures treated as STAT. 3. Blood cultures delivered to Microbiology every half hour, and directly by pneumatic tube system. 4. Blood cultures accessioned as priority, loaded directly. RESULTS All steps in processing of positive blood cultures were reviewed and value stream mapping was done. Data collected to determine current state revealed that only 20% of positive blood cultures were finalized with identification as positive. Controllable steps in blood culture processing identified to have an impact on this figure were: time to accession blood cultures, time to load blood cultures into automated equipment, time to investigate blood cultures signaled as positive, review of culture for early growth to begin investigations, time to receive, review and release results of identification and susceptibility tests, the number of technologists working on blood cultures at critical points, and the order of work flow on the blood cultures bench. Results are represented in Tables 1-3 and Graphs 1-5. CONCLUSIONS Applications of LSA have not been widely reported from Microbiology Laboratories. This study demonstrates that LSA can be used to improve the time to reporting of final blood cultures results after initial detection of a positive blood culture. In our study, the percentage of positive results finalized at 24 hours after initial identification improved from 19% to 40%. This benefit was a result of LSA applied to both pre-analytic and analytic blood cultures processes. Heightened awareness 2

around the importance of expedited blood cultures processing led to much improved handling from collection to entry into the BACTEC, and earlier positivity from time of collection. The blood cultures analytic process was enhanced by standardized work flow, prompt handling of positive blood cultures, early review of growth, and additional technologists assigned to the blood cultures bench during critical times. LSA led to improvements in other VGH Microbiology processes: A cleaner and less cluttered environment in which to work. A better organized physical lay-out to decrease extra motion. New and standardized workflow processes, posted as appropriate, and very importantly An enthusiastic and energized microbiology laboratory staff. AUTHORS Roscoe D., Whitley A., Garcha H., Namocatcat S., Reid J., Walker R. Division of Medical Microbiology & Infection Control, Department of Pathology & Laboratory Medicine, Vancouver General Hospital, Vancouver Coastal Health, Vancouver, B.C., Canada Project Technologists: Angela Whitley, Harjinder Garcha, Stephanie Namocatcat, with Richard Walker as champion. Table 3: Work Flow for Analytic Processing of Blood Cultures, Pre- and Post-LSA. Pre-LSA: Post-LSA: Not standardized Standardized 1. Blood cultures not staffed to accommodate busy work periods. 2. No protocols for order of work flow. 3. Review of plated cultures for early setup inconsistently performed, or done too early in the day. 4. Positive signal from machine not monitored on afternoon shifts when staff in other laboratory areas. 1. Blood cultures helper assigned 0600 to 0800. 2. Protocols established standardized order of work. 3. Review of plated cultures standardized to be done at 1400 and 1630 (early set-up of biochemicals and susceptibility tests). 4. Monitor frequently to better detect positive signal when working in areas away from the BACTEC machines. REFERENCES 1.Tapping D., et al. 2003. Value stream management for the lean office. 2.BMG. 2002. Lean for transactional business processes. 3.Jacobson, J.M., et al. 2006. Lean and Six Sigma: not for amateurs. Lab Med. 37:78-83. [Notes: 1. This study was originally presented as a poster at the AMMI Canada-CACMID Conjoint meeting held in Vancouver, Feb 2008. It was reformatted as an article for the on-line newsletter CMPT Connections 2008; 12(1):2-4. 2. The terminology examination, preexamination and post-examination is used for analytic by CLSI GP26-A3; 24;36.] Graph 1 (above), graph 2 (below): Decreased time to enter blood cultures into BACTEC. Table 2: Time Measurements Pre-Analytic Processing of Blood Cultures. (Time reductions range: 31-100 minutes) Step in pre-analytic processing of blood cultures Laboratory reception to Microbiology accessioning. Microbiology accessioning to computer log-in. Computer log-in to load into blood cultures system. Pre-LSA Time ranges, minutes Post LSA Time ranges, minutes 1 to 118 1 to 45 1 to 71 1 to 40 1 to 110 1 to10 3

Spaghetti Diagrams (above): illustrate decreased motion with improvement in physical lay-out. (top left) Pre LSA (top right) Post LSA Graph 3 (left): Expediting blood cultures into BACTEC: more positive blood cultures detected during regular operating hours, decreasing time to initial positive from time of collection. Graphs 4 and 5 (above): Time to finalize results at 24 hours after initial positive improved from 19% to 40%. 4

Annex 15-C: Quality Indicators and ISO ISO 9001: 2000 (5.4.1) Top management should ensure that quality objectives, including those needed to meet requirements for product, are established at relevant functions and levels within the organization. The quality objectives shall be measurable and consistent with the quality policy. ISO 9001:2000 (8.4) The organization shall determine, and collect and analyze appropriate data to demonstrate suitability and effectiveness of the quality management system and evaluate where continual improvement of the effectiveness of the quality management system can be made. This shall include data generated as a result of monitoring and measurement and from other relevant sources. The analysis of data shall provide information relating to: customer satisfaction conformity to product requirements characteristics and trends of processes and products including opportunities for preventive actions suppliers. ISO 15189:2003 (4.12.4) Laboratory management shall implement quality indicators for systematically monitoring and evaluating the laboratory s contribution to patient care. When this program identifies opportunities for improvement, laboratory management shall address them regardless of where they occur. Laboratory management shall ensure that the medical laboratory participates in quality improvement activities that deal with relevant areas and outcomes of patient care. 5

Annex 15-D: Quality Indicators Examples The total testing process (pre-examination, examination, post-examination) includes all activities from the physician s decision to order a laboratory test through the return of information for patient care. The following examples of quality indicators can be used in a laboratory total testing process. ordered test is appropriate for patient care patient consent appropriately collected physician written order received with every sample cost benefits assessment for laboratory examination menu patient identification and its accuracy preparation of patient for specimen collection appropriate sample container timing of sample collection phlebotomy success sample integrity sample quantity sample transportation accuracy of sample identification condition for sample storage quality control external quality assessment or proficiency testing program time to first result availability result reporting accuracy adequacy of information for interpretation of laboratory tests report delivery turnaround time consistency of critical values reporting result interpretation by physician sample contamination laboratory injuries or accidents competency of laboratory personnel patient s satisfaction with laboratory services physician s satisfaction with laboratory services 6