Emergency Plan. This emergency plan provides a format of data essential in an emergency situation.



Similar documents
Abnormal Operating Conditions Emergency Plans and Public Awareness Plans for Natural Gas Systems

NATURAL GAS EMERGENCY PROCEDURES AND ACCIDENT PREVENTION

natural gas Control control of of Natural Gas in Emergency Situations

CHAPTER VIII. completeness of the operations and maintenance procedures; omission or deficiency of an applicable portion of the plan;

Family Emergency Preparedness Plan

Emergency/Disaster Response Plan

Preventing Overheated Boiler Incidents

This document contains the text of Secretary of the State regulations concerning

SHELTER-IN-PLACE OR EVACUATE

Natural Gas Emergencies

Module 14 Handling Emergency Situations

MAJOR PLANNING CONSIDERATIONS CHECKLIST

EMERGENCY PREPAREDNESS PLAN FOR

Emergency Response Planning for Small Waterworks Systems

SAFETY GUIDANCE MATERIAL

EVACUATION Fire / Explosion / Smell of Smoke / Gas Odor / Fire Alarm / Bomb Threat

Factors to Consider When Developing an Evacuation Plan

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

How To Handle An Emergency

Implementation Date: May 5, Table of Contents. Section Description Page. 1.0 Description Initial Response 2

SOCALGAS APROACH TO PIPELINE INTEGRITY

How To Handle An Emergency At A Strata Corporation

Fire Safety PROCEDURES January 2011

RESPONSIBILITY FOR GAS PIPING FOR YOUR CONVENIENCE

Emergency Procedures

Inspection, Testing and Maintenance

Disclosure of Customer Rights and Company Policies

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION

Assisted Living Facilities & Adult Care Comprehensive Emergency Management Plans

NATURAL GAS SAFETY. Your safety. Our priority Update

Emergency Response Manual

Comprehensive emergency plan for:

EMERGENCY RESPONSE PROCEDURES

POINT UNIVERSITY CAMPUS SECURITY Emergency Response Plan

WORKPLACE WRITTEN PROCEDURES OH&S Regulation, Section 3

Emergency Planning Guideline

ACCIDENT & INCIDENT RECORDING AND REPORTING POLICY

emergency action guide

RISD Hurricane Preparedness

would your business stay afloat?

DEALING WITH PLUMBING AND HEATING EMERGENCIES

Tabletop Exercises. Scenario 2 Gas Leak PHASE 1

Sam Houston State University

South Carolina Child Care Services. Child Care Emergency Plan Template

Fire Alarm and Protection Impairment Policy and Procedures

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

EVACUATION & EMERGENCY PREPAREDNESS PLAN

The Orange County Farmers Museum Emergency Preparedness Plan

Union College Campus Safety Emergency Action Guide

Disaster Ready. By: Katie Tucker, Sales Representative, Rolyn Companies, Inc

EMERGENCY PROCEDURES

Emergency Plans

EMERGENCY PREPAREDNESS & RESPONSE PROCEDURE

School pipeline safety information WHAT S INSIDE

Emergency procedures instructions to farm staff

EMERGENCY PREPAREDNESS PLAN

Honeoye Storage Corporation. Canandaigua New York Public Awareness Plan Part

EMERGENCY MESSAGE TEMPLATES

DISASTER RECOVERY PLANNING

SURVIVAL FACTORS GROUP CHAIRMAN S FACTUAL REPORT, Revision 1 1

VILLAGE OF GRANVILLE SEWER BACK-UP and WATER LEAK POLICIES

CITY OF HOUSTON HIGH-RISE OFFICE BUILDING FIRE SAFETY PLAN

EMERGENCY PROCEDURES

Reviewed: Revised: 12/09. Page: 1 of 9

Emergency Preparedness Guidelines

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

The Johns Hopkins Hospital and The Johns Hopkins University Health, Safety and Environment Manual Fire Safety:

EMP OF VIDYUT NAGAR GRAHA NIRMAN SAHAKARI SAMITI MARYADIT, GWALIOR

A cure for water damage in real estate

FLA S FIRE SAFETY INITIATIVE

General Fire Code Requirements Within Commercial Tenant Spaces

Occupational Health & Safety Policy Injury & Incident Reporting

would your business stay afloat? A guide to preparing your business for flooding

Emergency Procedures. Emergency Phone Numbers. Unisafe (Security) (07) or extension 4444 Police, Fire Service or Ambulance 1-111

Service Bulletin SA-008. DATE: June 18, 2008 TO: All Service and Parts Managers SUBJECT: Flood Damaged Appliances

Preparing Your Business for a Flood

EMERGENCY PREPAREDNESS

West Chicago Public Library District EMERGENCIES AND EMERGENCY SITUATION PROCEDURES

AMOUNT New Account Deposit $50.00 Service Delinquent $10.00 Delinquency Notification $15.00 NSF Check processing $20.00

EMERGENCY PROCEDURES

Sample Emergency and Critical Incident Policy and Procedure

EMERGENCY EVACUATION PROCEDURES

OCCUPATIONAL HEALTH AND SAFETY POLICY: INCIDENT AND INJURY REPORTING ERJ

SL280UHV SERIES GAS FURNACE WARNING

EMERGENCY ASSESSMENT AND RESOURCES

Central State University. Emergency Action Plan Quick Reference

Natural Gas Safety. What You Need to Know

Vishesh Diagnostics Pvt. Ltd. EMP

Working Relationship with Local Law Enforcement Authorities. Department of Safety and Security Scope of Authority. How to Report On-Campus Crime

Director, National Institute for Occupational Safety and Health. California Fatality Assessment and Control Evaluation (CA/FACE) Program

Operating instructions

BUSINESS CONTINUITY ASSESSMENT CHECKLIST

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

Transcription:

Emergency Plan A. Introduction This emergency plan provides a format of data essential in an emergency situation. B. Definition of Emergency Incident An emergency condition exists when we determine that extraordinary procedures, equipment, manpower, and/or supplies must be used to protect people from existing or potential hazards. These hazards may include, but are not limited to: 1. Facility failures that result in: a. Under-pressure in the system; b. Overpressure in the system; c. Large amounts of escaping gas; d. Fire, explosion, etc.; e. Any leak considered hazardous; and f. Danger to major segment(s) of the system. 1 Natural disasters (floods, tornadoes, hurricanes, earthquakes, etc.). 2 Civil disturbances (riots, etc.) 3 Load reduction conditions (result in voluntary or mandatory reduction of gas usage). C. Contents of Emergency Plan 1 Emergency Notification List 2 Map of Key Valve Locations 3 Emergency Equipment 4 Responding to Gas Leak Reports and Interruption of Gas Service 5 Major Emergency Check List 6 Reporting Requirements (Telephone Report) 7 Restoration of Gas Service After Outage 8 Education and Training 9 Accident Investigation 1. Emergency Notification List The telephone numbers of the operator, fire department, Gas Company and any other entity whose service may be necessary in an emergency must be readily accessible. A copy of this list will be posted in a public area. The direct lines to emergency services such as the fire department will be included in addition to the general emergency number (i.e., 911). These numbers will be kept up-to-date. Emergency Notification List (Page 8 of Emergency Plan)

2. Map of Key Valve Locations A system map that shows the location of master meters, key valves, pipelines, system pressures, and source of supply available will be included in the emergency plan. The map is readily available in an easily accessible emergency file. All employees know its contents and location. ONLY authorized personnel will operate valves. Fire, Police, and other officials, or other outside individuals ARE NOT AUTHORIZED to operate or to instruct others, including gas company personnel, to operate valves (except the end-use valve, commonly called the meter shut-off). 3. Emergency Equipment (State here the location of such equipment as key valves, maps and records, etc., necessary to adequately meet emergency condition, such as shutoff tools, backhoe, shovels, leak repair equipment, air compressor, jack hammer, and key valve wrenches.) Equipment Location Periodic checks of emergency equipment will be taken and records of these inspections shall be kept in file. Locations and addresses where additional manpower and equipment or supplies may be obtained are as follows:

4. Responding to Gas Leak Reports and Interruption of Gas Service Ask the person calling if they are in the area where they are smelling the gas, if they are ask them to put the phone down and leave. If they are calling from another location continue with the following: A. The employee receiving a report of a gas leak should get as much information as possible to properly fill out the leak report form. B. All reports of leaks on tenant premises get priority. LEAKS INSIDE A BUILDING GET TOP PRIORITY. C. After obtaining the information and determining a hazardous leak exists inside a building, remind the tenant of all the following information: 1. No one is to turn ON or OFF any electrical switches. 2. No one is to ring the door bells or use the phone, including cell phones. 3. Let the phone drop to the floor; do not hang it up. 4. Extinguish all open flames. DO NOT LIGHT MATCHES, CIGARETTES, ETC. 5. Turn off gas supply, if feasible. 6. Everyone in the building is to leave the building and go a safe distance, about a block away. GO ON FOOT-no engines or sparks. D. Properly trained personnel are dispatched to the location of the reported leak. E. Duties of first company employee on the scene: Take every corrective action necessary to protect life and property from danger (in that order). It is the responsibility of the person I charge to: 1. Set up communication. 2. Coordinate the operation. 3. Make all decisions concerning emergency valves (isolating areas) and the use of emergency equipment. 5. Major Emergency Check List (Page 7 of Emergency Plan) Implement the following check list: A. Leaks Outside Building 1. Extinguish all open flames. No smoking. 2. Assess danger to public, surrounding buildings, occupants, and property. 3. If necessary, notify fire and police. 4. Notify gas utility supplier. 5. Block street. 6. Notify supervisor or other responsible persons. 7. Bar probe next to foundation of building. 8. Check neighboring buildings for gas. 9. Repair leak. 10. When positively sure it is safe, return occupants to building.

B. Leaks inside Building 1. Evaluate immediately, and then determine concentration of gas and source of leak. 2. DO NOT operate any electrical switches. 3. DO NOT us phone, including cell phones. 4. Shut off gas meter valve. 5. If more than four percent of gas is present, open doors and windows, ventilate building. 6. Bar probe are especially around foundation. Check water meter and other openings. 7. If ground is gas free and if house is gas free, turn meter valve. CHECK ALL GAS PIPING AND APPLIANCES FOR LEAKS. (Is meter hand turning normally or spinning? Soap bubble test.) 8. Repair Leak. 9. If leak cannot be repaired, notify customer. Turn off meter, lock it, tag it, and leave. C. Gas Burning inside Building. 1. Call fire department. 2. Call gas utility supplier. 3. If fire is at an appliance, shut gas off at valve or, if not possible, shut gas off at meter or curb valve. 4. Bar probe area and use CGI to locate source of gas. D. Interruption in Gas Supply 1. An Interruption to gas supply line could be caused by: (a) freezing of the regulators; (b) break in line; (c) sabotage; (d) supplier cut-off; or (e) LP-Gas Tank out of fuel. 2. Call supplier (transmission Company, natural gas utility, or LP-Gas distributor). 3. Locate leak. Inform supplier of the location of leak, if possible. 4. Close appropriate valve to isolate the break (if necessary).

6. Reporting Requirements (Telephone Report) A. The Railroad Commission (RRC) of Texas must be notified by telephone as soon as practicable for any gas leak that: 1. Caused a death or an injured person required in-patient hospitalization. 2. Caused total property damage of $50,000.00 or more, including loss to the operator and others, or both, but excluding cost of gas lost. 3. Unintentional estimated gas loss of three million cubic feet or more. 4. Was significant even though it did not meet the other criteria. The telephone report, if required, should be made at the earliest practicable moment following discovery and at least within two hours. To notify RRC, call 512-463-6788 or toll free 844-773-0305. B. The telephone report for RRC should contain: 1. Name of operator. 2. The location, time, and date of incident. 3. Fatalities and personal injuries 4. All other significant known facts that is relevant to the cause of the leak or extent of the damages. (Describe accident.) 5. Who in management should be contacted upon arrival at accident site. 7. Restoration of Gas Service After an Outage When the gas supply has been cut off to an area, no gas will be turned on to the affected area until the individual service to each tenant has been turned off. The individual service to each tenant must be turned off, either at the meter or at service valves. If the service valves cannot be located, the service line must be uncovered; a service installed and then cut off. In restoring service to an effected area, all piping and meters must be purged and appliances re-lighted. Never turn on gas at a meter unless there is access to ALL appliances on the consumer piping. In the event a tenant is not at home, a message must be left in a conspicuous location requesting the tenant to call the office to arrange for restoration of service. The person in charge is to coordinate and be responsible for this operation. A complete record of the incident, with drawings, etc., shall be kept on file. 8. Education and/or Training A. Employee Training Employees must be periodically trained in emergency procedures, including but not limited to: 1. Update of Emergency Manual (Plan). 2. Review of employee responsibilities in an emergency. 3. Review of location and use of emergency equipment.

4. Review the locations and use of: a. System maps. b. Main records. c. Service records d. Valve records e. Regulator station schematics. f. Properties of natural gas and LP-gas 5. Take a hypothetical emergency situation and STEP BY STEP review the action to be taken, including public officials, firemen, police, local gas utility, etc. 6. Record Keeping. 7. Telephone reports to RRC. 8. Records shall be kept on file of attendance and items discussed. B. Public Education There shall be a continuing education program to teach tenants, the public, appropriate governmental organizations, and persons engaged in excavation-related activities how to recognize a gas emergency and reporting it to the proper location. 1. The program material shall include, but not be limited to: a. Information about gas properties. b. Recognition of gas odors. c. What to do and not to do when there is a strong gas odor. d. Notifying the gas operator prior to making excavations or excavation-related activities e. Gas operator phone number and after hours numbers to call for information or to report an emergency. 2. This information may be conveyed to the public by: a. Radio and television (if applicable). b. Newspapers, including apartment or condominium newsletters. c. Meetings d. Bill stuffers e. Mailings f. Hand-outs. g. Postings on bulletin boards Where there are tenants who do not speak English, this same information is related in their language so that they can understand it. Are record shall be maintained of the public education program.

c. Liaison with Public Officials and Local Gas Utilities Liaison with fire, police, civil defense, medical officials, and local gas utilities will be established and maintained with respect to emergency procedures. 9. Accident Investigation Procedures for analyzing accidents and failures are as follows: a. Investigation off all company facilities to determine if accident was gas related. 1. Leak survey. 2. Pressure tests of piping. 3. Meter and regulator check. 4. Questioning persons on the scene. 5. Examining burn and debris patterns. 6. Odorization level. 7. Recording meter reading 8. Weather conditions b. Procedures to follow if accident was gas related: 1. Selection of samples of the failed facility or equipment for laboratory examination for the purpose of determining the causes of the failure and minimizing the possibility of recurrence. 2. Notify insurance company

Major Emergency Checklist 1. Has fire department been called, if necessary? 2. Have persons been evacuated and area blocked? 3. Has police department been notified, if necessary? 4. Has repair crew been notified? 5. Has company call list been executed? 6. Have communications been established? 7. Has outside help been requested? 8. Have ambulances been called, if necessary? 9. Has leak been shut off or brought under control? 10. Has civil defense been notified, if necessary? 11. Have emergency valves or proper valves to shut down or reroute gas been identified and located? 12. If an area has been cut off from a supply of gas, has the individual service of each customer been cut off? 13. Is the situation under control and has the possibility of reoccurrence been eliminated? 14. Has surrounding area, including buildings adjacent to and across the street from, been probed for the possibility of further leakage? 15. Has proper tag been put on meter, if necessary? 16. Has telephone report to RRC been made, if necessary? 17. Has telephone report to DOT been made, if necessary? 18. Has news media been given instructions, if necessary? Date:

Emergency Notification List Owner: Phone Number: Owner s Operation Personnel: NAME ADDRESS PHONE EQUIPMENT Others to Notify: CONTACT NAME PHONE POLICE DEPARTMENT POLICE DEPARTMENT DEPARTMENT OF PUBLIC SAFETY FIRE DEPARTMENT GAS SUPPLIER RAILROAD COMMISSION 512-463-6788 RAILROAD COMMISSION 844-773-0305 NATIONAL RESPONSE CENTER CONSULTANT