Centricity Enterprise Web 3.0 DICOM Conformance Memo DOC0094970



Similar documents
HP Medical Archive Solutions DICOM Conformance Statement. January 2007 (Third Edition) Part Number T

Infinity Medical Image Server

Technical Publication. DICOM Conformance Statement. DICOM Proxy 2.0. Document Revision 3. October 20, Copyright Brainlab AG

ONIS 2.0 DICOM CLIENT. DICOM 3 Conformance statement

Version 8 DICOM Conformance Statement. Version 3.04, September 2014

Xeleris 2.0 Conformance Statement for DICOM V3.0

DICOM Conformance Statement FORUM

AquariusNET DICOM Conformance Statement. DICOM Conformance Statement. AquariusNET 4.4. Rev B

Dx MM DICOM 3.0 Conformance Statement

DOLPHIN DICOM IMAGING DICOM CONFORMANCE STATEMENT

Technical Publications

DICOM 3.0 Conformance Statement

g GE Medical Systems Advantage Cluster Storage / Archive System Release 1 v Conformance Statement Direction number: Revision: 2

Centricity TM RISi DICOM Conformance Statement

GE PACS Conformance Statement for DICOM v3.0

MiPACS Storage Server Conformance Statement Version

AGFA HEALTHCARE DICOM Conformance Statement

Technical Publications

DICOM 3.0 Conformance Statement

DICOM Conformance Statement CBS Images and Worklist Version 2.01

DICOM 3.0 CONFORMANCE STATEMENT

Technical Publications

Medflow Imaging DICOM Server

CARESTREAM PACS Suite (Client, Server, and CD Direct) Version DICOM Conformance Statement

DICOM Conformance Statement

DICOM Conformance Statement For Diagnostic Review Workstation Software Version 5-x MAN-00546

ClearCanvas ImageServer DICOM Conformance Statement

Hologic Physician s Viewer 7.0 DICOM Conformance Statement

Technical Publications

DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT FOR ZIOSTATION 2.0

DICOM Conformance Statement

Technical Publications

DICOM Conformance Statement. Version: 1.0

Varian System Server. DICOM Conformance Statement

Candelis, Inc. DICOM Conformance Statement. ImageGrid Storage Server

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

DICOM CONFORMANCE STATEMENT FOR ZIOCUBE 1.0

DICOM Conformance Statement Merge Eye Care PACS v. 4.0

Philips Medical Systems DICOM Conformance Statement

Workstation, Server Hosted

DICOM CONFORMANCE STATEMENT

DICOM Conformance Statement

Technical Publications

GENIE Acquisition R3.1 Conformance Statement for DICOM v3.0

MammoView 1.5. DICOM Conformance Statement 1.0. medigration GmbH All rights reserved

Understanding Digital Modalities: System Integration and Use

Product catalog 2014

DICOM CONFORMANCE STATEMENT STORAGE SCU, Q/R SCP, PRINT SCU & STORAGE COMMITMENT SCU FOR TOSHIBA SUPERCONDUCTING MRI SYSTEMS (MIIMR0001EAB)

AGFA MEDICAL IMAGING DICOM Conformance Statement

How To Connect Ifa Dicom To An Ophthalmology System

FUJIFILM MEDICAL SYSTEMS

Introduction CDR Dicom for Windows is designed as a fully functional DICOM (Digital Imaging Communications of Medicine) based client-server

Table of Contents. Version History

ConnectPro for CT/i 4.0 Systems Conformance Statement for DICOM v3.0

Universal Viewer Zero Footprint Client 1

Digital Imaging and Communications in Medicine (DICOM) Part 4: Service Class Specifications

Digital Imaging and Communications in Medicine (DICOM) Supplement 119: Frame Level Retrieve SOP Classes

Digital Imaging and Communications in Medicine (DICOM) Part 5: Data Structures and Encoding

Digital Imaging and Communications in Medicine (DICOM) Supplement 23: Structured Reporting Storage SOP Classes

MedBroker A DICOM and HL7 Integration Product. Whitepaper

Integrating the Healthcare Enterprise (IHE) Integration Statement

DICOM Conformance Statement

DICOM Conformance Statement

DICOM Conformance Statement

Supports screening, diagnostic, and multimodality workflows

DICOM Conformance Statement

DICOM Conformance Statement

Product Internationalization of a Document Management System

Department of Veterans Affairs VHA DIRECTIVE Veterans Health Administration Washington, DC February 8, 2011

A PACS-Aware DICOM Image Object

Success of DICOM standard

PARCA Certified PACS Interface Analyst (CPIA) Requirements

DICOM CONFORMANCE STATEMENT

Integrating the Healthcare Enterprise (IHE) Integration Statement

DICOM: Definitions and Testing

Extracting, Storing And Viewing The Data From Dicom Files

DICOM CONFORMANCE STATEMENT

DICOM Correction Proposal

DICOM Conformance Statement. GDxPRO

DigitizingStation. DICOM V3.0 Conformance Statement

Integrating the Healthcare Enterprise (IHE)

The Evolution of PACS Data Migration

Tools for DICOM Implementation

Network Management for Picture Archiving and Communication Systems (PACS)

JiveX Enterprise PACS Solutions. JiveX HL7 Gateway Conformance Statement - HL7. Version: As of

OpenEMR: Achieving DICOM Interoperability using Mirth

PACS Migration. Herman Oosterwijk, OTech, Inc. & Greg Burch, Laurel Bridge Software OTech Inc./Laurel Bridge Software

Printlink5-ID_IV. DICOM 3.0 Conformance Statement PRINT MANAGEMENT SYSTEM CODE NO Manufacturer:

7i Imaging on Demand PACS Solution FAQ s

The Ongoing Relationship of PACS with the RIS, the HIS, and Other TLAs. Richard L. Morin, Ph.D., FAAPM

GE Healthcare. Size it up. Centricity cardiovascular PACS solution

SIGNA PROFILE CONFORMANCE STATEMENT

MiPACS Storage Server

Digipass Authentication For IIS Basic 3.2

DICOM. Conformance Statement. Envisor Software Version C.0

Transcription:

DOC0094970

CONTENTS 1 Introduction... 3 1.1 Scope and Purpose... 3 1.2 Intended Audience... 3 1.3 Scope and Field of Application... 3 1.4 References... 4 1.5 Definitions... 4 1.6 Symbols and Abbreviations... 4 1.7 Revision History... 4 1.8 Important Considerations for the Reader... 5 2 Implementation Model... 6 3 DICOM Conformance... 7 3.1 SOP Classes... 7 3.2 Support for defined terms denoting supported character sets... 8 3.3 Centricity PACS V3.0 backend... 8 3.3.1 Send to a remote system... 8 3.3.2 Query a remote system (C-FIND)... 8 3.3.3 Retrieve from a remote system (C-MOVE)... 8 3.4 Centricity RA600 V7.0 backend... 9 3.4.1 Send to a remote system... 9 3.4.2 Query a remote system (C-FIND)... 9 3.4.3 Retrieve from a remote system (C-MOVE)... 9 3.5 Centricity Archive V3.0 backend... 9 3.5.1 Send to a remote system... 9 3.5.2 Query a remote system (C-FIND)... 9 3.5.3 Retrieve from a remote system (C-MOVE)... 9 GE Healthcare 2005 Page 2 of 9

1 Introduction 1.1 Scope and Purpose This document describes the DICOM Conformance for Centricity Enterprise Web 3.0. The DICOM Conformance of Centricity Enterprise Web 3.0 is fully determined by the DICOM application Centricity Enterprise Web is hosted on: Centricity PACS V3.0 Centricity PACS V2.1 Centricity RA600 V7.0 Centricity Archive 3.0 (a.k.a. Centricity Enterprise Archive) This memo is intended as a substitute for a separate DICOM Conformance Statement. It identifies the sections of the respective conformance statements that either do or do not apply. These DICOM conformance statements can be found on the GE Healthcare website at http://www.gehealthcare.com/usen/interoperability/dicom/index.html. 1.2 Intended Audience The reader of this document is concerned with software design and/or system integration issues. It is assumed that the reader of this document is familiar with the DICOM Standards and with the terminology and concepts that are used in those Standards. If readers are unfamiliar with DICOM terminology they should first refer to the DICOM Standard (see the section References), prior to reading this document. 1.3 Scope and Field of Application The combination of this Centricity Enterprise Web and the DICOM Conformance Statements of the applications Centricity Enterprise Web is hosted on, describe how the Centricity Enterprise Web application collaborates in a DICOM network with other Medical Imaging applications that conform to the DICOM standard. GE Healthcare 2005 Page 3 of 9

1.4 References See Digital Imaging and Communications in Medicine (DICOM) 2004, parts 1 through 16. Other document sources: Document ID Title Author Revision DICOM Conformance various various - statements GEHC DOC0045635 CWeb 2.1 DICOM Conformance Statement Stephan 1 Heerkens DOC0046112 Centricity Enterprise Archive Version 2.1 Michael 3 CONFORMANCE STATEMENT for DICOM V3.0 Dubbeldam DOC0094938 Centricity Enterprise Archive Version 3.0 Victor Derks 1 CONFORMANCE STATEMENT for DICOM V3.0 DOC0054138 DICOM Conformance Statement for RA600 v7.0 Jan-Pieter 2 Diender DCM-1030-001/00- Centricity Radiology RA600 V6.1 Conformance Statement Jan-Pieter 6.1.1 002 for DICOM V3.0 Diender DOC0001464 Site Quality Plan GEHC IT Zeist David van Weering 6 1.5 Definitions See Digital Imaging and Communications in Medicine (DICOM) 2004, parts 1 through 16. 1.6 Symbols and Abbreviations See Digital Imaging and Communications in Medicine (DICOM) 2004, parts 1 through 16. See DICOM Change Proposals. CP-252 (Support for Chinese character sets) The name Centricity Archive used in this document refers to Centricity Archive V3.0 (a.k.a Centricity Enterprise Archive) The name Centricity Web or Centricity Enterprise Web used in this document refers to Centricity Enterprise Web 3.0. The abbreviation GEHC is used for General Electric Healthcare. 1.7 Revision History Revision Comment 1.0 First version (updated version of CWeb 2.1 ) GE Healthcare 2005 Page 4 of 9

1.8 Important Considerations for the Reader This DICOM Conformance Statement by itself is not sufficient to guarantee successful connectivity between Centricity Web, its host applications, and equipment from other vendors. The following considerations should be made: This document describes the conformance of Centricity Enterprise Web 3.0 and is not applicable to earlier releases (or predecessors) of Centricity Enterprise Web. The integration of equipment from different vendors (including GEHC) goes beyond the scope of the DICOM standard and the DICOM Conformance Statements from GEHC and other vendors. It is the responsibility of the user (or user s agent) to assess the application requirements and to design a solution that integrates GEHC equipment with equipment from other vendors. When the comparison of this DICOM Conformance Statement with a DICOM Conformance Statement from another vendor indicates that connectivity should be possible it is the responsibility of the user (or user s agent) to verify this by carrying out validation tests and to check whether all required functionality is met. With regard to the future evolution of the DICOM standard, GEHC-IT Zeist reserves the right to make changes to the Centricity Web architecture described in this document. The user (or user s agent) should ensure that any equipment connected via DICOM to GEHC equipment also follows the future evolution of the DICOM standard. Failure to do so may result in (partial) loss of connectivity. GE Healthcare 2005 Page 5 of 9

2 Implementation Model Centricity Web consists of two main applications: a server and a client. This document focus is the server. The Centricity Web server consists of a Centricity Web-specific module (DLL) that runs as part of Microsoft Internet Information Server. This DLL receives all HTTP requests from any Centricity Web client, and processes them. The Centricity Web server communicates with host services mentioned before for database query/retrieve and study file retrieve. All DICOM communications are handled by the respective services. Centricity Web does not initiate or accept them. For easy reference, the implementation model is depicted below. RA600/ CA1000 CWeb Enterprise Archive Centricity (RIS)PACS GE Healthcare 2005 Page 6 of 9

3 DICOM Conformance The Centricity Web server adheres to the DICOM Conformance statement of the backend it is hosted on. This section adds remarks to the various numbered sections of the respective DICOM Conformance Statements. See also: http://www.gehealthcare.com/usen/interoperability/dicom/index.html 3.1 SOP Classes Although the hosted services may support more SOP Classes, Centricity Web clients are only able to request and display objects belonging to the SOP Classes in the table below. Centricity Web Storage SOP classes supported for display SOP Class Name SOP Class UID CR Image 1.2.840.10008.5.1.4.1.1.1 DX Image (Presentation) 1.2.840.10008.5.1.4.1.1.1.1 DX Mammography Image (Presentation) 1.2.840.10008.5.1.4.1.1.1.2 DX Intra-oral Image (Presentation) 1.2.840.10008.5.1.4.1.1.1.3 CT Image 1.2.840.10008.5.1.4.1.1.2 US Multi-frame Image (Retired) 1.2.840.10008.5.1.4.1.1.3 US Multi-frame Image 1.2.840.10008.5.1.4.1.1.3.1 MR Image 1.2.840.10008.5.1.4.1.1.4 NM Image (Retired) 1.2.840.10008.5.1.4.1.1.5 US Image (Retired) 1.2.840.10008.5.1.4.1.1.6 US Image 1.2.840.10008.5.1.4.1.1.6.1 SC Image 1.2.840.10008.5.1.4.1.1.7 Grayscale Softcopy Presentation State 1.2.840.10008.5.1.4.1.1.11.1 XA Image 1.2.840.10008.5.1.4.1.1.12.1 NM Image 1.2.840.10008.5.1.4.1.1.20 Basic Text Structured Reports 1.2.840.10008.5.1.4.1.1.88.11 Key Object Selection 1.2.840.10008.5.1.4.1.1.88.59 PET Image 1.2.840.10008.5.1.4.1.1.128 RT Image 1.2.840.10008.5.1.4.1.1.481.1 GE Healthcare 2005 Page 7 of 9

3.2 Support for defined terms denoting supported character sets Centricity Web has support for the following character sets (without/with code extensions): Supported Character Sets Name Value Default Character repertoire <none>, ISO 2022 IR 6, Japanese (Katakana/ Romaji) ISO_IR 13, ISO 2022 IR 13 Multi-byte JIS X 0208 (1983) ISO_IR 87, ISO 2022 IR 87 Latin 1 character repertoire ISO_IR 100, ISO 2022 IR 100 Latin 2 character repertoire ISO_IR 101, ISO 2022 IR 101 Latin 3 character repertoire ISO_IR 109, ISO 2022 IR 109 Latin 4 character repertoire ISO_IR 110, ISO 2022 IR 110 Greek ISO_IR 126, ISO 2022 IR 126 Arabic ISO_IR 127, ISO 2022 IR 127 Hebrew ISO_IR 138, ISO 2022 IR 138 Cyrillic ISO_IR 144, ISO 2022 IR 144 Latin 5 character repertoire ISO_IR 148, ISO 2022 IR 148 Korean ISO_IR 149, ISO 2022 IR 149 Multi-byte JIS X 212 ISO_IR 159, ISO 2022 IR 159 Unicode in UTF-8 ISO_IR 192 GB18030 GB18030 Whether extended character sets are displayed correctly very much depends on the characteristics of the backend system and the validity of the DICOM header contents. 3.3 Centricity PACS V3.0 backend Centricity Web does not directly initiate or accept DICOM associations on the Centricity PACS V3.0 backend. Centricity Web communicates directly with the Image Volumes defined in the Centricity PACS STS configuration. 3.3.1 Send to a remote system Centricity Web clients cannot actively designate studies to be sent to a remote system when connected to Centricity PACS. 3.3.2 Query a remote system (C-FIND) Centricity Web clients cannot actively query other DICOM systems when connected to Centricity PACS. 3.3.3 Retrieve from a remote system (C-MOVE) Centricity Web clients cannot actively retrieve images from other DICOM systems when connected to Centricity PACS. GE Healthcare 2005 Page 8 of 9

3.4 Centricity RA600 V7.0 backend 3.4.1 Send to a remote system Centricity Web clients cannot actively designate studies to be sent to a remote system. However, automatic routing rules can be configured using the Centricity RA600 functionality. 3.4.2 Query a remote system (C-FIND) If the Centricity Web server is hosted on a Centricity RA600 V7.0 backend, the Centricity Web client can do a remote query, which is relayed by the Centricity Web server as a Study- or Patient Root Query to the Centricity RA600 V7.0 backend, and then to a remote system. 3.4.3 Retrieve from a remote system (C-MOVE) If the Centricity Web server is hosted on a Centricity RA600 V7.0 backend, the Centricity Web client can do an import action for a selection of studies. This will initiate the transfer of images from the remote system to the Centricity RA600 V7.0 database (effectively acting as a cache) on the Centricity Web server. The imported studies thus become available for viewing to the Centricity Web client. 3.5 Centricity Archive V3.0 backend 3.5.1 Send to a remote system Centricity Web clients cannot actively designate studies to be sent to a remote system. However, automatic routing rules can be configured using the Centricity Archive 3.0 functionality. 3.5.2 Query a remote system (C-FIND) If the Centricity Web server is hosted on a Centricity Archive 3.0 backend, the Centricity Web client can do a remote query, which is relayed by the Centricity Web server as a Study- or Patient Root Query to the Centricity Archive 3.0 backend, and then to a remote system. 3.5.3 Retrieve from a remote system (C-MOVE) If the Centricity Web server is hosted on a Centricity Archive 3.0 backend, the Centricity Web client can do an import / fetch action for a selection of studies. This will initiate the transfer of images from the remote system to the Centricity Archive 3.0 database (effectively acting as a cache) on the Centricity Web server. The imported / fetched studies thus become available for viewing to the Centricity Web client. GE Healthcare 2005 Page 9 of 9