Ademco Vista-20P/First Alert FA-168C Basic Commands



Similar documents
GE Concord 4 Quick User Guide

How To Use An F145C-1 With A Sim Sims 2 (Aq) And A Sims 1 (Aux) (Aipa) (For Aq) (F145C) (Ios) (Power

ADEMCO VISTA-48A ADEMCO VISTA-48E Security Systems

3 6HFXULW\6\VWHP 8VHU*XLGH K4333 9/99 AWAY BYPASS STAY ALARM FIRE ARMED OFF AWAY STAY READY MAX TEST BYPASS INSTANT CODE CHIME

First Alert FA140C/142C Installer Notes M. Leuck

Using your LED Plus keypad

SECURITY SYSTEM NOTES

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

SECURITY SYSTEM NOTES

NetworX NX-6V2. LED Keypad User Manual

READY ARMED 2 AWAY 1 OFF 3 STAY B 5 TEST 6 C D MAX BYPASS 9 CHIME # 8 CODE INSTANT READY I I I I I I FA560 K4855V1 3/00

FA701 Series. User s Guide. K6249-2V2 5/09 Rev. A

Vision Security System OWNER MANUAL V-LCD1

Using Your. Security System With Icon Keypad S5020, S5021, S5022

6HFXULW\6\VWHPV 8VHU V*XLGH K5309-1V1 8/01

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

SECTION DETECTION AND ALARM

HILLS Series LED Code Pad User Manual

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

ICP-CC488. Installation Guide ICP-CC488 Control Panel

MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3

SECURITY SYSTEM MANUAL

User's Manual 5120XM N8031 6/96

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

Solution-16 Operators Manual ISSUE 1.60

8VHU V*XLGH 6HFXULW\6\VWHPV (QWUHSUHQHXU(1 6HFXULW\0DQDJHU(1. Meets ADT Security Services Triple Standards Requirements:

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

User s Information Guide R1A

VISTA-50P VISTA-50PUL

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

POWER POWER ABC DEF GHI JKL ABC DEF GHI JKL COMMAND YZ COMMAND POWER ABC DEF GHI JKL COMMAND YZ USER'S GUIDE

616, 626, 636 & 646 Keypads

HILLS Series LED Code Pad User Manual

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

ABUS WIRELESS ALARM SYSTEM

Using Your. Security System. With LED Keypad S5030, S5031, S5032

Solution 880 Operators Manual ISSUE 1.10

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

IDS X-Series User Manual D Issued July 2012

Contact ID Codes. UNDEFINED DSC CONTACT ID CODE 104 RESTORE Zone Test/Misc. DSC CID RESTORE. 103 TECHNICIAN Unknown Test/Misc.

EVO48 EVO192. User Guide

VISTA-128FBP VISTA-250FBP Commercial Fire and Burglary Partitioned Security Systems with Scheduling

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

Contact ID Event Definition Codes

System Manager s Manual

Users Guide to Keypad Functions

Contact ID as of 2/2/2015

Security System. User's Manual VISTA-20BAY. N /98 File No: S1632 SINCE 1946

AMPS Information. The keypad pictures listed here may vary from your panel type.

Enhanced. Commercial Burglary Partitioned Security System with Scheduling. User Guide. K4970-1V3 4/09 Rev. B FA560 3 STAY 2 AWAY 1 OFF 5 TEST 9 CHIME

GE Simon XT Quick User Guide

Emergency Dialer DIAL-ALERT MODEL: AD

CONTENTS 4. HOW TO UNSET THE PANEL...7

Solution 16 plus. User Guide Security System

USER'S MANUAL. N7527-1V2 Rev B 4/99

SCORPION. micron security products

Lynx Plus Series Security System

ADEMCO LYNXR-EN Security System

tattletale User Guide Consumer unit version P a g e

SPECIAL CONTROL BUTTON FUNCTIONS

VR8. User Guide Intruder Alarm System

VISTA-100. Commercial Fire and Burglary 8VHU*XLGH. Partitioned Security System. N Rev B 4/99 FIRE FIRE PULL

ICP-CC488 ICP-CC488 EN. Control Panel. Quick Reference Guide

Control/Communicator Installation Manual

USER'S MANUAL. N7527-1V2 Rev B 4/99

Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

LYNX Touch Security System

Changes or modifications not expressly approved by Interlogix, Inc. can void the user s authority to operate the equipment.

CS250 LCD Keypad User Manual

ADEMCO LYNXR-I Security Systems

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

PowerWave-8. Users Operating and Programming Guide Version zone Control panel Communicator

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

Simon Security System. User Guide EUR Rev A August Part No: ZZZJHVHFXULW\FRP. Motion. Doors & Windows

LYNX Touch L5210 Series Security System

AMAX 2100 / 3000 / en User Guide

Changes or modifications not expressly approved by Interactive Technologies, Inc. can void the user s authority to operate the equipment.

XR6/XR10 User s Guide

Solution 862 Operators Manual. Issue 1.00

Simon XT User Manual R-11 and R-11-CN P/N REV B ISS 13JAN11

NESS D Zone Control Panel and Dialler OWNER S MANUAL

LYNX Touch Security System

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

NOTE: The home screen always displays the day and month, time, & P1 (Partition 1)

MOBILE CALL GSM alarm system

Simon Security System Installation Instructions

S I E R R A PRODUCT INFORMATION GUIDE FOR HOME SECURITY. SIERRA Page 1

User's Manual VIA-30PSE, VISTA-10SE. N7229V2 Rev B. 1/97

GC2 Panel User Guide

GSM ALARM SYSTEM USER MANUAL

Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: R. CareGard. User Guide

5HDG\*XDUG5 6HFXULW\6\VWHP 8VHU*XLGH K /00 OFF AWAY STAY AUX

User's Manual. For use with ProSYS 16, ProSYS 40, and ProSYS 128

PhoneWatch Smart Security System User Manual - Domonial

MANUAL. FA142C Security System. N7229 1V2 Rev B 4/99

Quick Installation Guide LCD GSM ALARM SYSTEM LH

NetworX Series. NX-148E LCD Keypad. User Manual

astec Integrated Alarm System USER GUIDE

Transcription:

Zones 64 total Ademco Vista-20P/First Alert FA-168C Basic Commands Wireless Yes, Zones 09 to 48 + 16 Keyfob Zones (Zones 49 to 64) Batteries Downloadable Partitions 2 12 volt Rechargable inside main Panel, AC Transformer 16 volts Door/Windows 3-Volt Lithium Motion Sensor 2 3-Volt Lithium Smoke Detector 2 9-volt Alkalines Remote Keypads 3-Volt Lithium Keyfobs 3-Volt Lithium Remote Panics 9-Volt Lithium Yes Panic Buttons Police Panic - * and # Fire Panic - 1 and * Medical Panic - 3 and # Status Arm Away Arm Stay Instant Arm Max Arming Quick-Arm Disarm Silence Alarm Bypass Press * if keypad shows NOT READY to view open zones 4-digit code + 2 (AWAY) to arm everything 4-digit code + 3 (STAY) to arm all but motions 4-digit code + 7 (INSTANT), this also bypasses motions 4-digit code + 4 (MAX) and everything arms instant # + 2 for AWAY, # + 3 for STAY 4 digit code + 1 (OFF) 4-digit code + 1 (OFF) twice to turn off siren and reset display (If code is entered wrong, wait 2 or 3 seconds then try again) 4-digit code + 6 (BYPASS) + zone (01, 02 03 etc) (keypad will beep, BYPASS + Zone should show, arm system) Quick Bypass User Code + 6 + # (Bypasses all open Zones) Alarm Memory Reset Smoke Door Chimes See Event Buffer 4-digit code + 1 (OFF) twice to turn off siren and reset smoke (If this does NOT reset smoke detector set for service, smoke is bad) 4-digit code + 9 (CHIME) GoTo Partition 1. User Code + * 2. Enter Partition 0 = Return to original Partition 1 = Partition 1 2 = Partition 2 3 = Common Lobby Partition 3. Keypad will return to original partition in 2 minutes or with User Code + * + 0 User MUST be assigned for multiple partition access in User Codes section Voice Keypads Voice Chime # + 0 + 2 + 4 to Enable or Disable (Keypad should say "ON" or "OFF") Show Status # + 0 + * Show Faults Press * * Record Message 1. Press # + 0 + 1 (LED turns ON) 2. Record message up to 2.5 minutes 3. Press 1 to end (LED begins FLASHING) Play 1. Press # + 0 + 3 Message 2. Recorded message will play (LED turns OFF) Adjust Volume Press # + 0 + 2 then press 3 or 6 to raise or lower volume Phone Test 1. 4-Digit Code + 5 (TEST) + 1 2. Keypad will send test signal If successful keypad will show "Phone Okay" or "Cd" If unsuccessful keypad will show "Comm Failure" or "FC"

Test Sensors 4-Digit Code + 5 (TEST) + 0 Keypad will beep every 40 seconds Open sensors and keypad will sound End test with 4-digit Code + 1 (OFF) key (Wireless motions require no movement for 4 minutes prior to testing) View Time/Date (Alpha Keypads only) Master Code + # + 63 Set Time/Date Event Buffer (Stays on for 30 seconds) (Alpha keypads will display menu, standard keypad will show nothing) (WARNING: Do not set clock for 01/01/03 to 08/31/01 or panel cannot be downloaded!) 1. User Code + # + 63 2. Press * within 30 seconds 3. Enter 2-digit Hour (00 to 12) 4. Enter 2-digit Minute (00 to 59) 5. Press 1 for PM, press 2 for AM 6. Enter last 2 digits of Year (01 to??) 7. Enter 2-digit Month 8. Enter 2-digit Day 9. Press * to exit or wait 10 seconds (Keypad will not give any confirmation beep) (Alpha Keypads only) 1. Enter Master Code + # + 6 + 0 2. Press * for previous event or # for next (Display shows last Alarm or event) Make Macros 3. Press any key other than * or # to exit Note: Display shows Contact ID event, click "Format" button for details U = User P = Partition (if available) and time/date it occured (if Installer enabled, a Function key can be set to allow multiple functions with 1 button) (Alpha Keypad) 1. While system is disarmed enter Master Code + # + 6 + 6 2. Select which Macro to program 1 or 2 3. This is current Macro programming (none), to program press * 4. Lets program system to bypass zones 02 and 03 and Arm Away 5. Press 6 (Bypass key) then 02 (Zone 02) and 03 (Zone 03) 6. Press D (bottom Function key) to save the command 7. Press 2 (Away key) 8. Press D (bottom Function key) to save the command 9. To exit press D (bottom Function key) for 2 seconds Other possible commands that can be used 3 = Stay Arm 4 = Max Arm 7 = Instant Arm

Use Macros (Any Keypad) #7 + 01 to 18 = Start External Relay or X-10 Device #8 + 01 to 18 = Stop External Relay or X-10 Device (Macro Key must be previously programmed by Installer or by downloading) 1. Enter User Code 2. Press assigned Macro Key (Function Key) Activate Relay 4-digit Code + # + 7 + Relay Number (01 to 16, 17 & 18) Deactivate Relay 4-digit Code + # + 8 + Relay Number (01 to 16, 17 & 18) Pager Signals Alarm sends Account + 911 + 3 digit Zone Open sends Account + 101 + 3 digit User Close sends Account + 102 + 3 digit User Trouble sends Account + 811 + 3 digit Zone Latchkey Page 777-7777 Manual Page 999-9999 Send Page Press assigned Pager key for 2 seconds (Must be setup by Installer) Schedules 1. Enter with Master or Installer Code + # + 64 (Alpha Keypad) (Master Code can program Schedules 01 to 16, Installer can program 17 to 32) 2. Select Schedule to program then * 3. Enter Event you want to occur then * (01 to 32 or 00 to exit) 3a. if 01 was selected this screen appears, enter Device then * (00 to 11) 00 = Clear Event (Deletes programmed event) 01 = Relay On/Off 02 = User Access (Allow Arming and Disarming) 03 = Latch Key Report to Pager 04 = Forced Stay Arming 05 = Forced Away Arming 06 = Auto Disarm 07 = Display "Reminder" 10 = Display Custom Words 8, 9 and 10* 11 = Periodic Test Report* *These options accessable with Installer Code only (00 to 18) 3b. if 02 was selected this screen appears, enter group then * (1 to 8) Assign User Group Master Code + 8 + User (02 to 49) + Group (1 to 8) 4. Enter Partition then * 5. Enter START Time & Days of Week 0 = All Partitions 1 = Partition 1 2 = Partition 2 3 = Common Lobby Partition Example: For a STOP time of 12:30 PM Tuesday Enter 12 30 then 1 for PM (0 if AM) Then press * until cursor is under T (Tuesday) then 1 to select, 0 de-selects Press * until display moves to next screen 6. Enter STOP Time & Days of Week

Example: For a STOP time of 06:15 AM Saturday Enter 06 15 then 0 for AM (1 if PM) Then press * until cursor is under S (Saturday) then 1 to select, 0 de-selects Press * until display moves to next screen 7. Select if is is a one time only Schedule or if it repeats then * 0 = Do not repeat/one time only 1 = Repeat schedule weekly 2 = Repeat schedule every other week (Biweekly) 3 = Repeat schedule every third week 4 = Repeat schedule every fourth week 8. Enter if schedule will be random, keypad will exit programming (Example if shedule is set for 6:15 event will happen between 6:00 and 6:59) 0 = No 1 = Yes 9. Select next Schedule to program or 00 then * to exit (01 to 08 or 00 to exit) To program monthly test signal 1. Enter Installer Code + # + 64 2. Select schedule 11 3. Enter START Time of 0230 AM then select 1 under which Day of Week 4. Do not select a STOP event 5. Select 4 under REPEAT OPTION for every fourth week 6. Enter 1 at RANDOMIZE to allow test signal within a 1 hour time frame

Ademco Vista-20P/First Alert FA-168C User Codes System Master Code User 02 Partition 1 Master Code User 03 (Partitioning can be changed) Partition 2 Master Code User 33 (Partitioning can be changed) Secondary Codes Partition 1 User 03 to 32 (Partitioning can be changed) Secondary Codes Partition 2 User 33 to 49 (Partitioning can be changed) Babysitter/Guest Code Any User Code Hostage Code Any User Code Do Not pause more than 2 seconds while entering commands or it will work Program Master Installer Code + 8 + 02 + New Master Code Change Master Master Code + 8 + 02 + New Master Code twice (Keypad should beep) Add Code Master Code + 8 + User Number + New User Code (Keypad should beep) Erase Code Master Code + 8 + User Number + # + 0 (Keypad should beep) Authority Level 1. Master Code + 8 + User User Number + # + 1 (Optional) 2. Enter Authority Level for User 0 = Standard User (Default) 1 = Arm Only 2 = Babysitter/Guest Code (Disarms only if Armed by Guest Code) 3 = Duress Code 4 = Partition Master Code 3. Keypad should beep and exit Partition Assign 1. System Master Code + 8 + User Number + # + 3 + 0 (Optional) 2. Enter Partition to assign this User Number (Multi Partitions can be assign)ed 1 = Partition 1 and Common Partition 2 = Partition 2 and Common Partition 3 = Common Partition Only OR a combination of 1, 2 and 3 3. Press # to save and exit Example: Change User 33 to Partition 1 and Partition 2 System Master Code + 8 + 33 + # + 3 + 0 + 1 + 2 + # Pager Enable Master Code + 8 + User (02 to 49) + # + 5 + 1 (Turns ON paging for User) Pager Disable Master Code + 8 + User (02 to 49) + # + 5 + 0 (Turns OFF paging for User) User Group Master Code + 8 + User (02 to 33) + # + 2 + Group (1 to 8) (For use with scheduling (see Basic Commands)

Ademco Vista-20P/First Alert FA-168C Trouble Display For Module Trouble System displays 1 + Address of Module Alpha Keypads Standard Keypads Description BELL FAILURE CHECK 70 Siren Trouble CANCELED ALARM CA Alarm has been cancelled by customer CHECK 01-56 CHECK 01-56 Zone is not communicating with panel, Sensor trouble CHECK 91 CHECK 91 Trouble with a Keypad or External Module/Expander CHECK 100 CHECK 100 Wireless Receiver Trouble/RF Keypad Tamper CHECK 103 CHECK 103 Long Range Radio Trouble CHECK 104 CHECK 104 4286 Voice Module Trouble CHECK 107 CHECK 107 4219/4229 Zone Expander/Relay Module 1 Trouble to CHECK 111 CHECK 111 4219/4229 Zone Expander/Relay Module 5 Trouble CHECK 112 CHECK 112 4204 Zone Expander Module 1 Trouble to CHECK 115 CHECK 115 4204 Zone Expander Module 4 Trouble CHECK 116 CHECK 116 Keypad 1 Trouble to CHECK 123 CHECK 123 Keypad 8 Trouble CHECK 128 CHECK 128 5800TM Module Trouble (for wireless) COMM FAILURE FC Failure to communicate with monitoring station DIALER OFF do Internal Dialer has been disabled EXIT ALARM EA Alarm triggered within 2 minutes of arming (not a trouble) KEYPAD LOW BAT 00 BAT Wireless Remote Keypad low battery LONG RNG TRBL bf Radio backup failure/trouble MODEM COMM CC System is being downloaded by Tech Support OPEN CIRCUIT OC Keypad trouble or wire broken to Keypad PHONE OKAY Cd Phone test was sent okay RCVR Jam CHECK 90 Interference with RF Receiver TELCO FAULT CHECK 94 Telephone Line Failure TEST IN PROGRESS dd Phone test in progress UPLOAD COMPLETE dc Tech Support uploaded system okay UPLOAD FAILED df Tech Support failed to upload system E4 or E8 E4 or E8 More zones were programmed than wireless receiver is capable of using One Beep every 40 Sec Smoke Batteries System is in Test Mode (Press Code + 1 to exit Test Mode) Remove old batteries, hold test button 30 seconds, add new batteries