IT-12M IT-12D Ver_2.0 INTERPRETATION SYSTEM. User s Manual



Similar documents
MANUAL PC1000R

The Bouncer Bluetooth Stereo Speaker

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

1 All safety instructions, warnings and operating instructions must be read first.

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

DAB+ / FM Tuner Model: TU-201

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

TS-770 SERIES CONFERENCE SYSTEM

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

S/PDIF D/A Converter. User Manual. Rev.B, December 2011 Audial d.o.o Belgrade, Serbia

Hear The Future...Now! SIEM-2T/SIEM-2R

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

MA-4150 ORDERCODE D6149 Highlite International B.V.

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

Congratulations! Thank you!

DAB2+ Dear Customer, Congratulations with your new Argon DAB2+

Advantium 2 Plus Alarm

PR-D9W. GB Version 1

MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.

LOXONE 12 Channel Amplifier

To reduce the risk of electrical shocks, fire, and related hazards:

QUALITY AV PRODUCTS INMATE/INMATE USB PROFESSIONAL 19" MIXER. User Guide and Reference Manual

eela-audio EA916 Journalist Unit USB Audio module with Telephone Hybrid User manual

SUB 10 ACTIVE STUDIO SUBWOOFER

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

D/N VANDAL RES. VARI-FOCAL IR DOME CAMERA

BOSE. Link AL8 HOMEWIDE WIRELESS AUDIO LINK

IMPORTANT SAFETY INSTRUCTIONS

SP-1700 OWNERS MANUAL

User Manual. For additional help please send a detailed to Support@phnxaudio.com. - 1 Phoenix Audio Technologies

D/N VANDAL RES. VARI-FOCAL DOME CAMERA

LDG DTS-4/4R Desktop Coaxial Switch / Remote

esata External Storage

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

How To Use A Sata Dsa Hard Disk Storage System

Safety Warnings and Guidelines

CX Zoner Installation & User Guide

SCD Server. SCD Server Pro

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

PORTABLE ALARM CLOCK. Dual Alarm. FM Radio. Wake-up Sounds. USB Phone Charger G-1CR

TOA 900 SERIES II MIXER POWER AMPLIFIER

OPERATING MANUAL PUBLIC ADDRESS POWER AMPLIFIER PA-9336

USER MANUAL. 914 Power Amplifier MODEL: P/N: Rev 1

How To Use A Pump Station 16-R

QLINK User Manual Stereo Audio Transmitter

Evolution Digital HD Set-Top Box Important Safety Instructions

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

Innkeeper PBX. Desktop Digital Hybrid. User Guide. JK Audio

Tone Hammer 500. Owners Manual. Manual Version 1.0

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

LT-82 Stationary IR Transmitter

COLOR VIDEO DOOR PHONE CDV-71BE/D

FT-100 Fire Training Fog Machine User Manual English

Doorbell Intercom Security System

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

19 LED Tube Controller ORDERCODE 41003

ES-CAM2AU IP Camera.

ECR Shelf System Installation Guide Centralized Rack Mount Call Recording

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Antenna Splitter ASA 1. Instruction manual

INSTRUCTION MANUAL MODEL PCD-88

AM / FM Tuner + RDS. Model: TU

VoiceTone T1 USER S MANUAL

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

MIC-WKT and MIC-WKT-IR

LED BAR 126 / 252 RGB. Owner s Manual LED BAR RGB

HOME THEATER SYSTEM. Instruction Manual. Model ASR150. Please read the instruction manual carefully before using your unit.

Single Day Alarm Clock with. Bluetooth and USB Play-through

DAB Radio. Instruction Manual L55DAB10

User Manual. Please read this manual carefully before using the Phoenix Octopus

VIDEO DOOR PHONE SYSTEM

D/N VANDAL RESISTANT 700TVL VARI-FOCAL IR DOME CAMERA CMR6082X/6082MX3.6 N/P CMR6086X/6086MX3.6 N/P

KZ0224UW INSTALLATION MANUAL SURGE PROTECTED CCTV POWER SUPPLY 24V AC, 5 AMP KZMI /12/01

Gemini II. Subwoofer System OWNERS MANUAL

900 MHz Lightweight Wireless Stereo Headphones

1. Product Description

HCS-3600MB2 Conference Main Unit

Operation Manual. Multi Channel Power Amplifier DPA-430L


Cable Tester Pro ORDERCODE D1909

OPERATING INSTRUCTIONS

12-Volt 10-Amp Regulated Power Supply

Video Keyboard Mouse Audio automatic Switch CAS-241, CAS-441, CAS-441-PM

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

Model PS-4001 Power Supply User Instructions

DAR-101. GB Version 1

DAB Adapter 2+ Dear Customer,

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

HDVD 800. Pure audio in perfection. Instruction manual

SAFETY WARNINGS. Important Safety Instructions. FCC Notice. Caution

e-4 AWT07MLED 7 Q TFT LCD MONITOR (LED Backlighted) USER MANUAL

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

Zone Mixer. 6 channels configurable from 24 inputs. 3 zone outputs. Expandable via Sys-Link TM Built-in comp/limiter, ducking and alarm functions

Rack Mount LCD KVM Assembly Installer/User Guide

User Manual. DXS-1000 Player

Active Monitor Box McCrypt S.T.E.V.E. 15. Order No

Transcription:

IT-12M IT-12D Ver_2.0 INTERPRETATION SYSTEM User s Manual

Important Notice All the safety and instructions for operation and use of the equipment should be read carefully before the system is operated. Please keep this user manual for future reference. Please follow all the operation instructions. Cleaning: Make sure to turn off the power supply before cleaning. Use a dry soft cloth to clean the equipment. Don t leave the product in a place with high humidity and temperature. Do not use any accessory, which is not recommended by the manufacturer. Do not place the equipment on an unstable stand; Please use appropriate package or original package by the manufacturer before transport to avoid damage caused by strong shake during transporting. Adequate ventilation is good for the maintenance of the equipment. Power supply AC 100-240V. Grounding: 3-wire grounding plug. Hot swapping is prohibited. Total 11 sets of IT-12D can be connected in one system. The cumulative cable length should not exceed 70 meters. For particular requirement, please contact the nearest JTS Service Centre for information. For service, please contact the nearest JTS Service Centre. Do not take the equipment apart by unauthorized personnel. All JTS products are guaranteed for 1 year except for the cases as follows caused by personal reasons: A : Damage or malfunction caused by personal factors such as dropping, striking and so on. B : Damage or malfunction caused by improper handling of the operator. C : Parts loss or damage by taking apart by a unauthorized personal. Only use JTS tailor-made cables to connect the system. Turn off the power supply and unplug the equipment from the power supply in case the equipment is not in use for a long time. Upon receipt of the product, please fill out the Warranty Card enclosed and post it to JTS Service Centre nearby in your region.

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN TO REDUCE THE RISK OF ELECTRIC SHOCK,DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE. CAUTION: To reduce the risk of electric shock, DO NOT open covers, no useable serviceable parts inside. Refer servicing to qualified service personnel only This label may appear on the bottom of the unit due to space limitations. The lightning flash with an arrowhead symbol, with an equilateral triangle, is intended to alert the user to the presence of uninsulated dangerous voltage within the products enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation mark within an equilateral triangle is intended to alert the user to the presence of imporyant operating and maintenance (servicing)instructions in the literature accompanying the appliance. WARNING:To prevent fire or shock hazard, do not expose units to rain or moisture Attention: Installation should be performed by qualified service personnel only in accordance with the National Electrical or applicable local codes. Power Disconnect: Units with or without ON - OFF switches have power supplied to the unit whenever the power cord is inserted into the power source; however, the unit is operational only when the ON - OFF switch is in the ON position. The power cord is the main power disconnect for all units.

INDEX 1. System Introduction 2. Product Introduction 2-1 Language Distributor // IT-12M 2-2 Interpreter Console // IT-12D 2-3 Accessories 3. System Installation & Connection 3-1 General Description 3-2 System Connection // Connection Cables 3-3 Connection of Audio Cables 3-4 System Mounting Instructions 4. System Setup & Operation 5. Technical Data 1 2 2 4 7 8 8 9 10 12 13 15 Remark: JTS Company reserves the right to modify any issue without notice in advance. If any detailed information needed, please contact the local agent or JTS distributor in your region. JTS is the registered trademark of JTS Professional Co., Ltd.

1. System Introduction The JTS IT-12 interpretation system consists of IT-12M and IT-12D. The IT-12M works as main unit to provide power, input and output interface, and control. The IT-12D is an interpreter console allowing two interpreters work together. Interpreters can choose either floor channel for original language for direct interpretation or relay interpretation available via the relay select key. For small venue crossing interpretation is available here. The whole system supports 11 interpreter consoles for simultaneous interpretation and delivers 12 languages to audiences. The product is a stand along system. It is compatible with any conference system. So no matter a new installation or an existing project needing expansion with interpretation IT-12 can easily meet the requirement. Together with JTS wireless system and any infrared system more audiences can participate in a conference. 1

100-240 VAC 50-60Hz Max. for 120W FUSE:T2A/250V Power For Wireless Transmitter 12V 300mA INTERPRETER S CONSOLE OUTPUT ORIGINAL INPUT SLOW OUT GND ALARM IN 2. Product Introduction 2-1 Language Distributor // IT-12M 1 2 3 4 5 6 9 10 12 13 7 8 11 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 COMBO socket microphone input: This COMBO socket provides +48V Phantom power to a microphone with balanced XLR or unbalanced φ6.3 connector. The input signal will be mixed with the Original (CH0). Gain: Adjust input sensitivity of the COMBO socket. The adjustable range is ±10dB. Interpreter channel indicator: Light-On to indicate the correspondent channel is active. Flashing to indicate the correspondent channel is standby. Signal level indicator: the brightness of this LED indicates the signal level of the correspondent channel. Power on indicator (Red). Power Switch: Push the on this switch will be turn system on, and push the on this switch will turn system off. Power supply socket (3-wire grounding plus) with built in fuse, T2A/250V. DC power output: The IT-12M includ 12 outputs of DC power supply (+15V/500mA) to wireless transmitters, like JTS TG-10STX tabletop wireless transmitter. Interpreter console interface (D-sub 25pin socket):11 interpreter consoles can be connected in daisy chain (IT-12D). Record IN connector (RCA): external signal from play back devices will be mixed with the Original (CH0) for recording. Record output connector (RCA): Connect to recording equipment. The original signal (CH0) mixed with REC. IN will be recorded. 2 INTERPRETATION SYSTEM

12 13 14 15 16 17 18 Original (CH0, floor channel) output (RCAx2/symmetrical output) : Original (CH0) balanced output with RCA connecters. 12CH audio output interface: #0 to 11 correspond to the Original (CH 0) and 11 sets of Interpreter Consoles. Signals are for distribution to audiences via JTS wireless systems. Notice: any channel not in use will be assigned with CH0 as input. Original (CH0) volume control: This potentiometer adjusts the Original (CH0) sensitivity. Adjustable range is ±10dB. Original (CH0) input socket: This φ6.3mm balanced connecter is connected to an output of a conference system or PA as the original signal of the interpretation system. Alarm sound input:φ6.3mm jack / unbalanced input. Slow output: When a Slow Key on the IT-12D is activated this Slow output will generate an 1 sec. pulse to request the lecturer to slow down. Alarm control input: A short cut of Alarm Ctrl. and GND will activate alarm procedure. All channels will receive alarm signal, and indicator LED will change from Light-On to Flashing. 3

MIC INPUT +48V PHANTOM POWER OFF SET ON 3 4 2 5 1 6 7 11 8 10 9 INPUT OUTPUT 3 4 2 5 1 6 7 8 10 9 LOCK MODE OPEN MIC INPUT +48V PHANTOM POWER B 2-2 Interpreter Console // IT-12D 30 28 31 32 29 30 19 20 ENTER MICROPHONE OUTPUT CHANNEL 1 2 3 4 5 6 7 8 9 10 11 21 21 A REC OUT MIC IN EARPHONE 33 34 35 22 23 24 25 VOLUME A ORIGINAL MONITOR RELAY 11 VOLUME B MONITOR RELAY ORIGINAL 22 23 24 25 33 34 35 MIC IN REC OUT EARPHONE 26 26 MIC.A ON/OFF COUGH CUT SLOW COUGH CUT MIC.B ON/OFF 27 ENTER key: To set the active channel of interpreter console. When switch on Switch the ENTER indicator starts flashing. After push one of the selectable channels (from CH1 to CH11 with Light On) this active channel can be stored to this interpreter console by pushing the ENTER key. Then switch off the Switch 28 to end the procedure. CH1~CH11 Channel Output Key: MODE switch at LOCK position: Under setting state, press it to select a selectable channel (indicator on) for interpretation output. Only 1 channel can be set in one Interpreter Console. The indicator of the activate channel is in green. MODE switch at OPEN position: All of channel indicator are off when power on initially. All channels are open to interpreter as long as it is not occupied by others. When the channel is activated the Channel Output Key is in green. The indicator flashes in red which means this channel is in use by others. Note: MIC. ON/OFF at OFF state, the activate channel will be released when this channel number on other interpreter console is selected. 19 28 20 4 INTERPRETATION SYSTEM

21 22 23 24 25 26 27 28 29 30 31 Relay interpretation monitor (MONITOR): After pressing RELAY key, an interpreter can turn the monitor rotary knob to select an interpreted language he/she can understand to interpret. Headphone volume control (VOLUME A, VOLUME B): To adjust the volume of the headphones. Relay interpretation switch (RELAY): In case the interpreter doesn t understand the original language, they can press the key and switch Monitor to another interpreted language from other interpreter for further interpretation. Floor Channel Switch (ORIGINAL): When the system start, the setting is by default, press it to listen to the original language (the speech from CH0). Mute Key (COUGH CUT): In case the interpreter coughs. Keep pressing the key to mute the line, meanwhile the indicator is on. When released, the line returns to working status. MIC ON/OFF button (MIC.A ON/OFF, MIC.B ON/OFF): Press it to turn the microphone on, the indicator will be on. Press it again to turn off the MIC.Only one microphone can be on at a time. MIC. A and MIC. B will override each other. Reminder key (SLOW): In case the delegate speaks too fast for the interpreter to follow, press it to request the delegate to slow down. MODE setting switch (OPEN / LOCK): The MODE switch needs be decided before power on. At the OPEN mode an interpreter can activate any channel in any time as long as it is not occupied. All channels are set off at the initial state, then an interpreter must select channel key which he wants. At the LOCK mode the interpreter can choose only one output channel which will not be taken by other users (setting procedure refer to step 29 and System and Operation chapter for more detail). Setting switch (SET): When all Interpreter Console are connected, setting of a channel of each console is needed for first time installation at LOCK mode. First turn the Switch 29 to ON, the ENTER key will start flashing. According to above Step No.20 to select one channel for the console. Then turn the Switch 29 to OFF to finish the channel setting. To starting the channel setting procedure just turn the setting switches (SET) from OFF to ON. Finish the channel setting procedure by turn the setting Switch 29 from ON to OFF. XLR microphone input: Each interpreter unit including 2 balanced XLR microphone input sockets with +48V Phantom power. These balanced microphones will be mixed with MIC. A/B. Input interface (INPUT): to connect the first Interpreter Unit to the IT-12M and the second one to the Output interface of the first unit (25-pin socket). 5

32 33 34 35 Output interface (OUTPUT): for connection with the next Interpreter Unit (25-pin plug). Recorder interface (REC OUT): φ3.5mm stereo, for connection with a recorder to record the interpretation. (Available on both left and right side of the Interpreter Console). Microphone input (MIC IN): φ3.5mm dummy stereo, for connection with microphone(available on both left and right side of the Interpreter Console). Earphone output (EARPHONE):φ3.5mm stereo, for connection with interpreter headset (Available on both left and right side of the Interpreter Console). 6 INTERPRETATION SYSTEM

2-3 Accessories Accessories are standard parts for a complete system installation, general description are as follow: (1) IT-12-C3: 3 meter cable with D-sub 25-pin M/F on each end. Used to connect Interpreter Console (IT-12D) in daisy chain and to IT-12M. Connecters: 1 Plug, 1 Socket. (2)HPM-12 : Multi media Headset( headphone with microphone) Earphone:φ3.5mm stereo. One set bundled with IT-12D for monitoring and interpretation. Hi-Fi quality, ergonomic design for long time fatigueless wearing. 33Ωx2, φ3.5mm stereo jack x 2(Green: Earphone jack; Orange: Mic. Jack) Microphone Unit: φ6x5mm Frequency Range: 30-16000Hz Sensitivity: -58±3dB Impedance: 2.2KΩ Standard Operating Voltage: 3.0V 7

3. System Installation & Connection 3-1 General Description IT-12 Interpreter System has a compact dimension and is easy for installation. IT-12D interpreter consoles are connected in daisy chain and the first IT-12D is connected to the main unit IT-12M. A detailed description of IT-12 Interpreter System installation and connection will be given by diagrams and examples in this chapter. 8 INTERPRETATION SYSTEM

MICROPHONE OUTPUT CHANNEL MICROPHONE OUTPUT CHANNEL MICROPHONE OUTPUT CHANNEL MICROPHONE OUTPUT CHANNEL 3-2 System Connection // Connection Cables All consoles are connected via D-Sub 25-pin cable. A 25-pin 3 meter cable (with a plug and a socket) is included in each IT-12D Interpreter Console to connect the interpreter unit to Main Unit IT-12M or to each other. On the rear panel of IT-12D there are two D-Sub connecters, the INPUT is a plug and the OUTPUT a socket. Connect the plug from the 25-pin cable to the Main unit IT-12M then the socket from the 25-pin cable to the plug INPUT on the first Interpreter Console. And then connect the plug of the second 25-pin cable to the socket OUTPUT of the first Interpreter Console and the socket is connected to the plug INPUT of the next Interpreter Console. Then all the interpreter units are connected in daisy chain. As many as 11 interpreter units can be connected for 12 languages (including floor channel) interpretation. Extension cables can be used between Interpreter Consoles and Main Unit IT-12M (IT-12-C3/C6/C12/ C18). It is strongly recommended to use JTS tailor-made cables to ensure the best performance. CH1 CH2 CH3 CH11 9

3-3 Connection of Audio Cables Cable connection plays an important role in the long distance audio transmission. Improper connection will result in interference. For example: (1)Connection for Unbalanced to Balanced transmission cable: Practical example: after the audios from signal source of mono RCA output, they go through to the IT-12M balanced input LINE IN (φ6.3mm jack) via unbalanced output. 35 GND(SHIELD) shielded net 36 BAL. + OR UNBAL.HI. 37 BAL. - OR UNBAL.LO. 37 The cable can be as long as 200M 37 36 Audio signal cable(doubl-core shielded cable) 35 36 A jack: Signal source(unbalanced output) RCA jack B jack: Reception(balanced intput) φ6.3mm jack * Note: This connection is not applicable to Balanced to Unbalanced transmission. Otherwise, the signal source of balanced output may be damaged. (2)Connection for Balanced to Balanced transmission cable: Practical example: After the audios from wired and/or wireless microphones are mixed via the mixer, they go through to the IT-12M balanced input LINE IN (φ6.3mm jack) via balanced output. 37 The cable can be as long as 200M 37 36 Audio signal cable(doubl-core shielded cable) 35 35 36 A jack: Signal source(unbalanced output) φ6.3mm jack B jack: Reception(balanced intput) φ6.3mm jack 10 INTERPRETATION SYSTEM

(3)Connection for Unbalanced to Balanced XLR transmission cable: Practical example: the recording output of IT-12M REC. OUT (unbalanced output) to PA system or media recording input XLR interface (balanced input). 37 35 36 The cable can be as long as 200M Audio signal cable(double-core shielded cable) 36 37 A jack: Signal source(unbalanced output) RCA jack B jack: Reception(balanced intput) XLR connector * Note: This connection is not applicable to Balanced to Unbalanced transmission. Otherwise, the signal source of balanced output may be damaged. 11

3-4 System Mounting Instructions IT-12M Main unit Installation (1)Dimension (LxWxH):421 x 213 x 44mm (2)Colour: Silvery black (3)Weight:2.65Kg (4) L shape rack mount bracket for 1U 19-inch standard cabinet. (5)Mounting Instructions A pair of rack mount brackets are equipped with the IT-12M 38, unscrew the screws on both sides firstly 39, then fasten the brackets with these screws and put the IT-12M in the rack, finally install the unit onto the rack with 4 screws 40. 39 38 40 40 39 12 INTERPRETATION SYSTEM

4. System Setup & Operation 4-1 General Description This chapter provides a comprehensive and detailed description on how to setup and operate IT-12 Interpreter System Main Unit (IT-12M) and Interpreter Console (IT-12D). (1)OPEN Mode: Interpreter Console Output Channel Select (IT-12D) Select the Console with one of the Channel Output key 1, 2 11 ; for example: If you want this unit to be NO. 1; just press 1. Then the indicator on the key will light on in green while the channel is not occupied. If the indicator on the key flashes in red that means the channel is occupied by other units. When the MIC. ON/OFF of the activated channel is at OFF state, the activate channel could be released when other interpreter console selects the same channel number. (2)LOCK Mode: Interpreter Console Output Channel Select (IT-12D) Interpreter Console must be assigned with one unique output channel before being used. The procedure is as: a. Make sure the connection is correct, and then turn on the IT-12M. b. Turn the SET setting switch from OFF on the rear panel of the Interpreter Console to ON, the indicators of ENTER on the unit starts flashing. The indicators of available channels will turn RED. Pay attention only one channel can be activated. c. Assign the Console with one of the Channel Output key 1,2.11, for example: If you want this unit to be NO 1, just press 1. Then the indicator on the key will change to Green light, press ENTER key to store, the indicator of ENTER will keep light on; d. Turn the SET setting switch to OFF, the ENTER indicator will turn off, that means the output channel selecting procedure is completed; e. If cross interpretation is needed OPEN mode should be selected. f. Repeat the same procedure (Steps b~d) to assign all the Interpreter Consoles. (3)To Cancel Selected Output Channel (only for LOCK mode) a. Turn the SET from OFF to ON. b. Push the ENTER for 3 seconds. Then all Channel Output Indicators will turn off. c. Turn the SET from ON to OFF. The Console will be of factory setting now. 13

(4)The Operation of IT-12D Interpreter Console: The Interpreter Console is designed with digital technologies and used in conjunction with HPM-12 interpreter headset. Each Console allows two interpreters to work on it. The operation procedures are as follows: a. At LOCK mode, when the output channel is selected an interpreter only need push the MIC ON/OFF key to activate the microphone or deactivate it. b. At OPEN mode, an interpreter can press any Output Channel key to deliver the correspondent language. The available channel will show a green indicator. A flashing red indicator means the channel is occupied. c. Put on the headset, adjust the microphone to an appropriate position and control the volume (Floor language is ORIGINAL as defaulted). Press MIC. A/B ON/ OFF to start the interpretation. d. In case the interpreter doesn t understand the floor language. He/she can select a language familiar with from other interpreter for relay interpretation. First press RELAY key, the indicator will be on, and then switch the MONITOR to choose a familiar language for interpretation. e. In case the Interpreter wants to cough, keep pressing COUGH CUT key to cut off the language output, release it to continue the interpretation. f. When the speaker speaks too fast for the interpreter to follow, the interpreter can press SLOW key to remind the speaker to slow down. A pulse signal will come out as remind from the IT-12M to the speaker desk. g. Each Interpreter Console accommodates A/B two interpreters to work, the operation A/B interpreter is the same. 14 INTERPRETATION SYSTEM

5. Technical Data 5-1 System environmental Conditions Transport Temp.: -40 C~+70 C Operational Temp.: 0 C~+45 C Max. Relative humidity: <95% 5-2 Main Unit IT-12M Technical Data Item... Power supply... System consumption... DC power output... D-SUB power output... Line In sensitivity... Alarm In sensitivity... MIC In sensitivity... Alarm Ctrl... Slow output... CH0~CH11 output level CH0 balance output level REC OUT output level... REC IN input level... protocol... Dimension (LxWxH)... Color... Weight... Specification 110-240Vac 90W +15V/0.3A*12 DC+15V/2A -30dB±2dB LEVEL VR at MAX. -20dB±2dB -51dB±2dB Gain VR at MAX. Shorted to GND +12V,Pulse 1sec. 180mV±20mV 85mV-GND85mV±10mV 170mV±15mV -25dB±2dB RS-485 421*213*44mm Silvery Black 2.65Kg 15

Interpretation Unit (IT-12D) Technical Data Item... Unit power... Unit power consumption. MIC sensitivity... XLR MIC sensitivity... Earphone output level... REC OUT output level... Protocol... In/Out interface... Dimension (LxWxH)... Color... Weight... Specification DC+15V 100mA±10mA -45dB±2dB -45dB±2dB 120mV±10mV at 33Ω load, volume MAX. 140mV±10mV RS-485 D-Sub 25P plug and socket 330*206*57mm Silvery-blue black 2.5Kg 16 INTERPRETATION SYSTEM