DO-6. Dissolved Oxygen Meter. Newport Electronics, Inc. Operator s Manual



Similar documents
OME-SERIES DATA ACQUISITION CARDS

MFT Series INTRODUCTION UNPACKING FERRULES

User s Guide. y = mx+b. Shop online at. A Guide to Calibration and Unit Conversion


User s Guide OSXL-100-PE. Thermal Imaging Camera Enclosure. Shop online at omega.com SM

User s Guide HHAQ IN-1 Psychrometer With Enthalpy. Shop online at omega.com SM

User s Guide. SOFTWARE FOR OMB-DAQ-2416 SERIES And OM-USB SERIES. Universal Library. Redistribution Guide. Shop online at

User s Guide DPF700-A. Analog Output Option Board for the DPF700 Meter. Shop on line at. info@omega.com

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Shop online at: omega.com For latest product manuals: omegamanual.info

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

ExStik TM ph Waterproof Meters

Milwaukee USER MANUAL

User s Guide EWS-RH. Relative Humidity/Temperature Transmitter. Shop online at omega.com

User s Guide TL-WELD. Thermocouple and Fine Wire Welder. Shop online at omega.com SM

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

User s Guide HFS-3, HFS-4. Shop online at. Thin Film Flux Sensors. omega.com info@omega.com For latest product manuals: omegamanual.

User s Guide. SW DIN Series and OSW Series. Shop online at. Rotary Selector Switches

Dissolved Oxygen Sensors

User s Guide MTC SERIES. Shop online at. Multi-Pin Thermocouple Connectors

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

User s Guide HHF81. Anemometer, Hygrometer, Light Meter, Thermometer. Shop online at omega.com

Duct Temperature Sensors

Global Water Instrumentation, Inc.

Retractable Screen. Replacement Screen Instructions

DISSOLVED OXYGEN PROBE

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

EzFlex Combustible Gas Leak Detector Model EZ40

Intelli-Time Alarm Clock model 13027

User Guide Dissolved Oxygen Probes

Part I - Installation

INSTALLATION INSTRUCTIONS. SharkBite. Connection System. The SharkBite System

Dual Laser InfraRed (IR) Thermometer

Pipe Temperature Sensors

In-Situ Inc. Warranty / Terms & Conditions / Software License. This warranty policy applies to items that shipped prior to January 1, 2012.

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

COMPLIANCE WITH LAWS, CODES, AND STANDARDS

Care and use guide. Contents. a handy solution made easy. page

ATS Overhead Table Shelf System INSTRUCTION MANUAL

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Instruction Manual Temp 4/5/6 Temperature Meter Series

Care and use guide. Contents. a handy solution made easy. page

Dual Laser InfraRed (IR) Thermometer with Color Alert

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

03-07 Ford 6.0 Powerstroke Installation Instructions and Manual P/N: 10401

81000 Series Aluminum Gate Valve Installation and Repair Manual

VW TDI (Golf, Jetta, New Beetle) Upgrade Turbocharger

RT-200 HI-TEST ROPE TESTER

Mold Alert... Operation Manual P0270

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

Triton Systems of Delaware, LLC. Warranty Statement

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Single Port T1/E1 Tap

24.2L M.A.N. V12 Engine Module

Mini-led spotlight with magnetic base

VW TDI (Golf, Jetta, New Beetle) Upgrade Turbocharger

Powerware Relay-Serial Card User s Guide

Commercial Cardiovascular Equipment

About this Manual. Support for Your Product

TEMPERATURE SENSOR USER MANUAL

Wolverine Data PASS Portable Scanner User Manual V1.0

AMC GENERIC WARRANTY POLICY GUIDE

Ozone Generator Manual

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

12-Volt Negative Ground Installation Instructions

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Owner s Manual & Safety Instructions

el-720 Carbon Dioxide Gas Leak Detector User s Guide

Sip/Puff Switch User Guide

ROTOR LOADER OWNER S MANUAL

DISSOLVED OXYGEN METER Model : DO-5509

MANUFACTURER S WARRANTY

PixController, Inc. Wireless Digital PIR Sensor

Unpacking, Installation, and Customization

PIR-1 Owner s Manual

Trace Dissolved Oxygen Sensor

Dual Laser InfraRed (IR) Thermometer

Crestron TMK-6L & WMKT-6L Trim Ring Mount Kits Installation Guide

Start Here Series. All-in-One Printer. Print Copy Scan. Includes Information on the: ESP 3250 All-in-One Printer ESP 3260 All-in-One Printer

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Conference Phone UserÕs Manual. Part No R1 Printed in Korea Bogen Communications, Inc.

Periodic Verification System Model 775PVS

Instruction Manual HI Refractometer for Sucrose Measurements

Fabric Sensor Evaluation Kit Information Sheet

Triton Systems of Delaware, LLC Warranty Statement / Return Policy

Dolphin 9900 Mobile Computers

Model 5101, 5102, 5103SL, 5110, 5111, 5115 STEEL SECURITY SAFE. Read this manual carefully and never store it inside the safe!

Atomic Alarm Clock model 13131W2

IMPORT CAST IRON THREADED FITTINGS Price Sheet SPF.CI-3.14C Effective March 10, 2014 Cancels Price Sheet SPF.CI-7.12C of July 2, 2012

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Microwave Meter. Instruction Manual

Limited Warranty for PV Modules

Transcription:

Dissolved Oxygen Meter Operator s Manual Newport Electronics, Inc.

Additional products from Newport Electronics, Inc. THE NEW STANDARD FOR QUALITY Clock/Timers Counters Flow Sensors Frequency Meters Multimeters On/Off Controllers ph Controllers ph Electrodes ph Pens PID Controllers Printers Process Meters Rate Meters Recorders Relative Humidity RTDs Soldering Iron Testers Strain Gauge Meter Thermistors Thermocouplers Thermowells Timers Totalizers Transmitters Voltmeters Wire In the USA and Canada: 800-NEWPORT In Mexico 95-800-NEWPORT Or call your local Newport Office. This documentation may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine readable form, in whole or in part, without prior written consent of NEWPORT ELECTRONICS, INC. 1995 Newport Electronics, Inc. All rights reserved. This product may be covered by one or more of the following patents: United States Patents Des. 336,895; 5,274,577 France Brevet No. 91 12756 Spain 2039150 United Kingdom Patent No. 2248954 and other international patents pending From the technical library of:

Warranty All Products from NEWPORT ELECTRONICS, INC. are warranted against defective material and workmanship for a period of one (1) year from the date of delivery. If the unit should malfunction, it must be returned to the factory for evaluation. NEWPORT s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by Newport, if the unit is found to be defective it will be repaired or replaced at no charge. However, this WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of NEWPORT s control. Components which wear or which are damaged by misuse are not warranted. These include contact points, fuses, and triacs. In addition to NEWPORT s standard warranty period, NEWPORT ELECTRONICS will extend the warranty period for one (1) additional year only if the warranty card enclosed with each instrument is returned to NEWPORT. Newport is glad to offer suggestions on the use of its various products. Nevertheless, NEWPORT warrants only that the parts manufactured by it will be as specified and free of defects. NEWPORT MAKES NO OTHER WARRANTIES OR REPRESENT- ATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total liability of NEWPORT with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall NEWPORT be liable for consequential, incidental or special damages. Every precaution for accuracy has been taken in the preparation of this manual; however, NEWPORT neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the products in accordance with the information contained in the manual. SPECIAL CONDITIONS: Should this equipment be used in any nuclear installation or activity, purchaser will indemnify NEWPORT and hold NEWPORT harmless from any liability or damage whatsoever arising out of the use of the equipment in such a manner. Return Requests Direct all warranty and repair requests/inquiries to the NEWPORT Customer Service Department. BEFORE RETURNING ANY PRODUCTS(S) TO NEWPORT, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM NEWPORT S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. NEWPORT s warranty does not apply to defects resulting from action of the buyer, mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting NEWPORT: 1. P.O. number under which the product was PUR- CHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult NEWPORT for current repair charges. Have the following information available BEFORE contacting NEW- PORT: 1. P.O. number to cover the COST of the repair, 2. Model and serial number of product, and 3. Repair instructions and/or specific problems relative to the product.

For technical or application assistance please call: Newport Electronics, Inc. 2229 South Yale Street Santa Ana, CA 92704-4426 TEL: (714) 540-4914, (800) NEWPORT FAX: (714) 546-3022 Newport Technologies Inc. 976 Bergar Laval (Quebec) H7L5A1, Canada TEL: (514) 335-3183 FAX: (514) 856-6886 Newport Electronics Ltd. Unit 25 Swannington Road Cottage Lane Industrial Estate Broughton Astley Leicestershire England, LE9 6TU TEL: 44 (1455) 285998 FAX: 44 (1455) 285604 Newport Electronics B. V. Postbus 8034 1180 LA Amstelveen The Netherlands TEL: 31 (20) 6418405 FAX: 31 (20) 6434643 Newport Electronics Spol S.R.O. Ostravska 767 733 01 Karvina Czech Republic TEL: 42 (69) 6311899 FAX: 42 (69) 6311114 Newport Electronics GmbH Daimlerstrasse 26 D-75392 Deckenpfronn Germany TEL: 49 (07056) 3017 FAX: 49 (07056) 8540 Newport Electronics S.A.R.L. 9 rue Denis Papin 78190 Trappes France TEL: 33 (1) 30.62.14.00 FAX: 33 (1) 30.69.91.20 In Mexico TEL: 95-800-NEWPORT 12958ML-01

TABLE OF CONTENTS DO-6 Unpacking Remove the Packing List and verify that you have received all equipment, including the following (quantities in parentheses):. Soft carrying case (1) 9V alkaline battery (1) Operator s Manual (1) The carrying case contains the following: Small screwdriver (1) DO-6 Meter (1) PHDG-8200 /N membrane kit (1) (It may be in a second box) If you have any questions about the shipment, please call the NEWPORT Customer Service Department. When you receive the shipment, inspect the container and equipment for signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent. NOTE The carrier will not honor damage claims unless all shipping material is saved for inspection. After examining and removing contents, save packing material and carton in the event reshipment is necessary. i

Page General Description... 1 Parts of the Meter...1 Setting Up the Meter... 2 Installing the battery... 2 Operating Instructions...3 Operating Tips... 4 Calibrating the Meter... 5 Table 1/Specifications... 6 ii

General Description The NEWPORT DO-6 meter combines a polargraphic dissolved oxygen sensor with an integral RTD for dissolved oxygen and temperature measurements in the lab, plant or field. By using a small cathode which consumes minimal oxygen, the need for sample stirring is minimized to provide a more stable response. Included are the sensor, screwdriver, and vinyl case. Optimal items for this meter include the extension cable (length - 2 meters) - NEWPORT part number CDEC-60/N, and replacement membrane kit for probe - NEWPORT part number PHDG-8200/N. Parts of the Meter Figure 1. Parts of the Meter 1

Setting Up the Meter Installing the Battery (Fig. 2) Carefully remove the meter from the carrying case making sure you don t lose the small screwdriver. To install/change the battery, do the following: 1. Insert your thumb in the recessed area of the battery compartment door and pull it away from the display. 2. Snap the 9V alkaline battery into the battery clip. 3. Place the battery clip/battery assembly at the top of the battery compartment. 3. Replace the battery compartment door and snap into place. Figure 2. Installing the Battery 2

Operating Instructions 1. Slide the stand-by switch to the stand-by position 30 minutes prior to using the Dissolved Oxygen (D.O.) meter. This polarizes the sensor and prepares it for testing. 2. Adjust the polargraphic D.O./Temp sensor to the 90 or 180 measurement position. 3. Remove the protective plastic cap. Rinse the sensor in distilled water and immerse the sensor 1/2 its length in the solution to be measured. 4. For the reading to be accurate, the solution must be stirred. If in the lab, use a magnetic stirrer. If in the field, stir the solution with the sensor, taking care not to bang the sensor. 5. The sensor should be at the same temperature as the solution. An integral 1000 ohm platinum RTD provides ATC and temperature reading. To read the solution temperature, depress the F/R switch. When (C) appears in the display and the reading has stabilized, read the temperature. When the standby switch is in the "OFF" position, the instrument cannot be turned on, preventing accidental actuation of the meter. 6. Press the F/C switch again ( PPM will be displayed), wait for the reading to stabilize (1 or 2 minutes), and take the dissolved oxygen reading. 3

Operating Tips When a constant shift in the D.O. reading is observed, the sensor should be cleaned and the old membrane replaced. Use the replacement membrane kit (NEWPORT part number PHDG-8200/N) to clean the probe. 1. Unscrew the lower cap portion of the probe and discard the fill solution that it contains. 2. Remove the serrated ring that holds the membrane in place (it is a force fit over the membrane and can be removed by twisting it and pulling it off the cap). 3. Remove the old membrane from the end of the cap. 4. Place the new membrane over the end of the cap, and force the serrated ring over the membrane (this will stretch the membrane tightly across the end of the cap). 5. Fill the cap with KCI filling solution, using the syringe provided in the kit. 6. Clean the glass tip with a tissue 7. Remove all spots and oxide from the metal tube. The metal tube should shine white, since it is made out of silver. 8. Screw the probe cap in place (excess fill solution will escape around the threads), and wipe clean. 9. The probe is now ready for use. 4

Calibrating the Meter The D.O. instrument is calibrated at the factory and ready for use upon receipt. Calibration should be verified periodically to insure accurate results. In order to calibrate, you will need an aerated water sample, and pure nitrogen or a sodium sulfite solution. 1. Slide the stand-by switch to the stand-by position 30 minutes prior to calibrating the dissolved oxygen meter. 2. Remove the protective cap and rinse with tap water. 3. Immerse the sensor in the aerated water sample. Make sure to allow the water sample to become thoroughly aerated. 4. Switch the instrument to the temperature range and observe the temperature reading. 5. Switch the instrument back to the D.O. (Dissolved Oxygen) function shown as PPM (Parts Per Million) on the display. 6. Use the temperature vs. PPM of D.O. chart to find the corresponding value. Refer to Table 1. 7. Adjust the instrument Span screw to indicate the correct PPM value. 8. Next, immerse the sensor in the zeroing solution (saturated sodium sulfite solution) for approximately five minutes. 9. Once the sensor has stabilized, adjust the Zero screw to zero. 10. The dissolved oxygen instrument is now ready for use. 5

Table 1 Dissolved Oxygen PPM vs. Temperature C PPM C PPM C PPM 0 14.6 12 10.8 24 8.5 1 14.2 13 10.6 25 8.4 2 13.8 14 10.4 26 8.2 3 13.5 15 10.2 27 8.1 4 13.1 16 10.0 28 7.9 5 12.8 17 9.7 29 7.8 6 12.5 18 9.5 30 7.6 7 12.2 19 9.4 35 7.1 8 11.9 20 9.2 40 6.6 9 11.6 21 9.0 45 6.1 10 11.3 22 8.8 50 5.6 11 11.1 23 8.7 Specifications Dissolved Oxygen Range: Resolution: Accuracy: 0.00 to 19.99PPM 0.01 PPM ± 1.5% FS Temperature Range Range: 0.0 to + 100.0 C Resolution: 0.1 C Accuracy: ± 0.2 C Automatic Temperature Compensation: 0 to 40 C Power: 9V Battery Dimensions: 6.25" x 1.25" x 2.25" Weight: 9.5oz 6