User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510



Similar documents
User Guide. Heavy Duty Dissolved Oxygen Meter. Model

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

DISSOLVED OXYGEN METER Model : DO-5509

User's Manual. Model Laser Photo / Contact Tachometer. Introduction

User Manual. Humidity-Temperature Chart Recorder. Model RH520

ExStik TM ph Waterproof Meters

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Dual Laser InfraRed (IR) Thermometer

EzFlex Combustible Gas Leak Detector Model EZ40

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

Dual Laser InfraRed (IR) Thermometer with Color Alert

Dual Laser InfraRed (IR) Thermometer

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Ground Resistance Clamp-On Tester

User's Guide Integrating Sound Level Datalogger Model

Milwaukee USER MANUAL

High Temperature InfraRed Thermometer with Laser Pointer

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

4-Channel Thermometer / Datalogger

Hygro-Thermometer + InfraRed Thermometer Model RH101

User's Guide. Digital Sound Level Meter. Model

User's Guide. Pinless Moisture Meter. Model MO257

Instruction Manual Temp 4/5/6 Temperature Meter Series

Light Meter (Foot Candles)

INSTRUCTION MANUAL DTH Fax: (503)

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

psi fth mbar * /0.1 cmh inhg bar

Ground Resistance Clamp On Tester

Soil Sensor Reader PRODUCT MANUAL

Microwave Meter. Instruction Manual

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

User Guide. Temperature and Humidity Datalogger. Model 42280

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

Temperature, Humidity & Dew Point Chart Recorder

Alarm Clock USER GUIDE

Professional Thermohygrometer

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Temperature Humidity Meter

DICKSON PW4 DICKSON. Pressure Chart Recorders. Applications & Specifications. Product. Getting Started, Charts & Accessories.

USER GUIDE. LED Light Meter. Model LT45

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Intelli-Time Alarm Clock model 13027

DO-6. Dissolved Oxygen Meter. Newport Electronics, Inc. Operator s Manual

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

Thermistor Thermometer MODEL NO

DISSOLVED OXYGEN PROBE

CM100. Carbon Monoxide Meter. Users Manual Mode d emploi Bedienungshandbuch Manual d Uso Manual de uso Användarhandbok

Automatic Phone-Out Home Monitoring Systems

1. SAFETY INFORMATION

SOUND LEVEL METER 94405

User Guide. 4 wire Earth Resistance Tester Model GRT300

User s Guide HHAQ IN-1 Psychrometer With Enthalpy. Shop online at omega.com SM

ECO SENSORS, INC. OZONE SENSOR AND MONITOR

Universal Wireless Effects Controller USER S GUIDE SA115

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

CHAPTER 1. GETTING STARTED... 1

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

ADVANCED INTERNET DOWNLOADABLE POSTAL & SHIPPING SCALE

Instruction Manual DO 110. Hand-held Dissolved Oxygen Meter with RS 232C. 68X Rev. 0-11/05. Technology Made Easy...

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

7 High-Resolution Digital Photo Frame

Model SRMD Setra Remote Monitoring Display

Care and use guide. Contents. a handy solution made easy. page

AS-801 Promotion-On- Hold Segregator. Version 2.10

AD-01 Slave Auto Dialer. Owner s Manual

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

CABLE MODEM QUICK START

EZ Hold USER MANUAL EZ HOLD. Music On Hold. Models M2060, EZM480. EZ ADVANTAGE CORP., 221, Broad Street, MILFORD, CT U.S.A.

12 Volt 30 Amp Digital Solar Charge Controller

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Water Leak Detection System

Wolverine Data PASS Portable Scanner User Manual V1.0

User Guide. Model Insulation Tester / Megohmmeter

Auto Dialer. Manual E-921APQ E-921GPQ

SHUTTER REMOTE USER MANUAL UNIVERSAL WIRED & IR RS-UWIR100 COMPATIBLE WITH MOST DSLR CAMERAS

DSM155 Digital LED Light Meter User s Manual DSM155

User s Guide HHF81. Anemometer, Hygrometer, Light Meter, Thermometer. Shop online at omega.com

Mold Alert... Operation Manual P0270

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

EE7016 EchoStream Survey Kit

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

PK5500 v1.1 Installation Instructions

el-720 Carbon Dioxide Gas Leak Detector User s Guide

DM Series CONTENTS. 1. Features Applications General Calibration Dimensions Specifications Calibration procedure 7

About Your NetBotz 4-20mA Sensor Pod

Quick Start Guide. Internet Conference Station X1-N6.

YSI Model 5000 YSI Model Dissolved Oxygen Temperature. Operations Manual

RS DIGITAL THERMOMETER

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Alarm Clock USER GUIDE

Weather Radio Alarm Clock

Care and use guide. Contents. a handy solution made easy. page

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Transcription:

User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510

Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved Oxygen, Oxygen in air, and Temperature. Units of measure are mg/l for Dissolved Oxygen, % for Oxygen in air, and o C/ o F for temperature. Oxygen is measured with a remote sensor that also contains a thermistor for measuring temperature. Advanced features include RS 232 PC serial interface, data hold, auto shut off, and Min/Max/Avg recording. Specifications General Specifications Circuit Custom one-chip LSI microprocessor circuit Display Dual function 0.5" (13 mm) 1999 count LCD w/ contrast adjust Measurements Dissolved O 2: mg/l (milligrams per liter); Oxygen in air: %; Temperature: C/ F Data hold Data hold key freezes displayed reading Sensor Structure Remote Polarographic Dissolved Oxygen Sensor Temperature sensor: Precision thermistor Data recording Min/Max/Avg readings stored for later recall Auto power off Meter turns off after 10 minutes Sample rate 0.4 Sec (approx.) Data Output RS 232 PC serial interface Operating conditions Temperature: 32 to 122 F (0 to 50 C); Humidity: < 80% RH Battery power 9V alkaline battery Power Consumption Approx. 6.6 ma DC Weight 0.74 lbs. / 335 g (including batteries & probe) Dimensions Main instrument: 7.1 x 2.8 x1.3" (180 x 72 x 32mm) Probe: 4.9" x 0.8" length/diameter (125 x 20mm) Accessories Carrying case, 9V battery, and 5 membranes Optional access. Membranes, data acquisition software & RS232 interface cable Electrical Specifications Measurement Range Resolution Accuracy Dissolved Oxygen 0.0-19.9 mg/l 0.1mg/L + 0.4 mg/l Oxygen in air 0-100% O 2 0.1 % O 2 + 0.7% O 2 Temperature (probe only) Compensation adjustments 32 to 122 o F 0 to 50 o C 0.1 o F/C ±1.5 o F + 0.8 o C Temperature (automatic) 32 to 122 o F (0 to 50 o C) Salt 0 to 39% Altitude 0 to 3900 meters Tech Support Hotlines 781-890-7440 ext. 200 extech@extech.com www.extech.com 2

Meter Description 1 LCD Display 2 POWER ON/OFF key 3 Data HOLD key 4 C/ F selection key 5 LCD Contrast Adjust 6 RECORD key 7 RECALL key 8 Factor adjust key 9 Probe top 10 Sensor body 11 Sensor plug 12 Sensor jack 13 RS-232 output jack 14 Battery cover 15 Altitude compensation key 16 DO/O 2 key 17 Zero key 18 O 2 calibration key 19 % Salt key Calibration For first time use or after long periods (several days) of non-use, calibrate the instrument using the following steps. The procedure should be performed in an open, wellventilated area. 1. Ensure that the sensor is DISCONNECTED from the meter. 2. Turn ON the meter. 3. Slide the O 2/DO selector to the O 2 position. 4. Press the zero key to null the meter (the display should indicate "OO"). 5. Connect the DO sensor to the top of the meter. 6. Allow the meter to stand for at least five minutes until the display stabilizes. 7. Press the O 2 Cal key and the display will indicate approx. 20.9 (typical O 2 in air). 3

Dissolved Oxygen (DO) Measurements Measurement Preparation Before taking measurements, perform the calibration described above if necessary. In addition, perform the % SALT and ALTITUDE compensation adjustments as described below: % SALT Compensation Slide the O 2/DO switch to the DO position. If the measured liquid is pure water or is known not to have a salt content, set the % Salt factor to 0%. 1. Press the % Salt key. The display will indicate 0% on the middle portion of the LCD display and S on the bottom portion of the LCD. 2. Pressing the Factor Adj. key once will add 1% to the salt factor. 3. Press the Factor Adj. key until the correct factor is displayed. 4. Press the % Salt key to store the factor. ALTITUDE Compensation The meter has a default calibration for sea level operation (0 meters). Any significant deviation from sea level requires a compensation adjustment. Perform the following steps to do so: 1. Press the ALTITUDE key and the display will indicate a 0 in the middle of the LCD and an H on the lower portion of the LCD. 2. Press the Factor Adj. key once to add 100 meters, twice to add 200 meters, and so on. Maximum compensation is 3900 meters. 3. Once the desired compensation is displayed, press the ALTITUDE key again to store the value. Taking Measurements 1. Immerse the probe in the solution under test. For best automatic temperature compensation, immerse the probe to a depth of at least 4" (10 cm). 2. Wait until the display stabilizes. 3. The velocity of the liquid coming into contact with the probe must be at least 0.6 to 1 ft/min (0.2 to 0.3 m/s). If the solution is standing, stir the solution with the probe or use an agitator. 4. Rinse the probe with clean water after each use. Oxygen in Air (O2) Measurements Follow the same steps above for DO measurements except for the variations described below: 1. Slide the O 2/DO switch to the O 2 position. 2. The display will indicate the oxygen air value in %. Temperature Measurements The lower display will indicate the temperature of the measured solution. Press the o C/ o F key to change the temperature units. 4

Advanced Features Data Hold Press the Data Hold key to freeze the displayed value. The LCD will display DH for Data Hold mode along with the held reading. Press the Hold key again to release the data hold function. MIN/MAX/AVG Data Recording When selected, the Data Recording function records the Min, Max, and Average readings. To start a data recording session: 1. Press the RECORD key once. The REC indicator will appear on the display and the meter will begin to record the lowest (min), highest (max), and average (avg) readings. 2. To recall the data, press the RECALL key once. The MAX indicator will appear along with the highest reading recorded since the RECORD key was pressed. 3. Press the RECALL key again to view the MIN value. 4. Press the RECALL key again to view the AVG reading. 5. To exit the Record mode, press the RECORD key again. The display indicators REC, MIN, MAX, and AVG will disappear. Auto Power OFF The meter includes an Auto shut off feature that preserves battery life. The meter will automatically turn off if no function button is pressed in any 10 minute period. To disable this feature press the RECORD key to engage the record function. LCD Contrast Adjust It may be necessary to adjust the display contrast due to a change in viewing angle or voltage drift. Use the LCD Contrast adjustment located on the right side of the meter to set the preferred contrast. Membrane & Electrolyte Replacement The tip of the probe holds a thin Teflon membrane and an electrolyte container. If the meter becomes difficult to calibrate or if the readings become erratic, check the probe for loss of electrolyte or a dirty/damaged membrane. The membrane is very delicate and can easily be damaged if it comes in contact with a solid object. Replace the electrolyte and/or the membrane as follows: 1. Unscrew the probe top. 2. Remove the O-ring and the old membrane. Refer to the diagram below. 3. Pour out the old electrolyte from the container. 4. Fill the container with new electrolyte. 5. Install the new membrane and the O-ring. 6. Reassemble the probe. 7. Lightly tap the probe to ensure that any air bubbles are forced out. O ring Membrane Fill 5

CPU Reset Certain improper keystroke sequences can cause the meter to hang and become inoperable. The following procedure will reset the meter. 1. Slide the O 2/DO switch to the O 2 position. 2. Turn the meter OFF and disconnect the DO probe. 3. Press and HOLD the O 2 key and then press the POWER key. 4. Release the O 2 key and then press the ZERO key. 5. Connect the DO probe. 6. Wait several minutes for the reading to stabilize and then press the O2 CAL key. RS-232 PC Interface The meter includes a RS-232 serial data port. This interface was designed to operate with the Extech Data Acquisition Software/Hardware kit Part No. 407000. This kit enables the user to capture, store and display readings using a PC. For more information contact Extech or refer to the 407000 User Manual for details. Battery Replacement The low battery indication LBT appears on the LCD when the battery runs low. To replace the battery: 1. Remove the meter's rubber protective cover to access the rear battery compartment. 2. Remove the battery compartment cover using a small coin or screwdriver and remove the 9V battery. 3. Replace the 9V battery and reinstall the cover and holster. Calibration and Repair Services Extech offers complete repair and calibration services for all of the products we sell. For periodic calibration, NIST certification or repair of any Extech product, call customer service for details on services available. Extech recommends that calibration be performed on an annual basis to insure calibration integrity. Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for 3 years from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 for authorization. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Copyright 2000 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form. 6