Load Banks and Load Testing Accessories. Simplex Onsite, Inc. SOS Rentals



Similar documents
in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

Load Bank Buyers Guide 60 hz models

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Photovoltaic Solar Energy Unit EESFB

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Three phase circuits

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

VOLTAGE REGULATOR AND PARALLEL OPERATION

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Digital Controllers ACTUATOR COMPATABILITY

SMART SENSOR COLLECTION

Three-Phase Electric Power Distribution for Computer Data Centers

GENERATOR SELECTION. a. Three phase - 120/208V, 3 phase, 4W wye; 277/408, 3 phase, 4W wye; * 120/240V 3 phase, 4W Delta

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

46120-F0 Solar Energy Training System

UPS Applications and VRLA Battery Sizing

Specifying a Variable Frequency Drive s

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Multi-Range Programmable DC Power Supplies 9115 Series

INSTALLATION & SERVICE MANUAL. Display Panel

TECHNICAL SPECIFICATION TYPE ATESO ALFA

Table of Contents. TransformerIQ FAQs 1

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Secondary Unit Substations

The Do s and Don ts of Pressure Transducers

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Diesel Engine Driven Generators Page 1 of 6

Chapter 24. Three-Phase Voltage Generation

Magnum Mobile Generator MMG55 Specifications

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

2012 Canadian Electrical Code, Part I (CEC) Top Fifteen changes

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Engineers Edge, LLC PDH & Professional Training

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

ATS Overhead Table Shelf System INSTRUCTION MANUAL

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

LOXONE 12 Channel Amplifier

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

vacon ac drives for mining & minerals

THE SOLAR TRANSFORMER. Portable Integrated Solar Power

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

Installation and Operation Guide for PD4000 Series Power Control Center

HERZ-Thermal Actuators

12 SOLAR PHOTOVOLTAIC POWER SUPPLY SYSTEMS by John Ware. PV modules are current-limiting

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Multi-Range Programmable DC Power Supplies 9115 Series

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

E2 Series Electric Furnaces

AuCom s IMS2 soft starters are a total motor starting solution, combining highlevel functionality with ease of use:

HEAVY DUTY STORAGE GAS

Short Circuit Current Calculations

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Failure code manual. content

Single-Phase AC Synchronous Generator

USB 3.0 Cables. Color. Black Black Black Black Black Black Black Black Black Black

RENEWABLE ENERGY SUBSTATIONS SOLAR PHOTOVOLTAIC AND WIND POWER. tgood.com. Energy. Fast.

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

ST Series POWER SUPPLIES USER INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Power Management Module 2. Installation

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

ATTACHMENT F. Electric Utility Contact Information Utility Name. For Office Use Only

Energy Storage System Performance Testing

Power Distribution Considerations for Data Center Racks

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

Unit 4: Electricity (Part 2)

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

Pow-R-Con Multi Function Control

Commercial Gas Furnace Upflow

INSTRUCTION MANUAL MODEL PCD-88

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Inductive Proximity Sensors

Air conditioning, electrical testing

Installation Instructions for Alarm Module Kit A043F059

VLT Series 300 Watt True Sine Wave Inverter

ABB PSPS Erich Steinmann; Generator control-2013

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

FAULT FINDING MANUAL. For Stamford AC Generators

HySTAT HYDROGEN GENERATORS

Transcription:

by Insight Onsite Load Banks and Load Testing Accessories Simplex Onsite, Inc. SOS Rentals

Fundamentals of Load Bank Rentals Page 2 Load Bank Testing of Electrical Power Sources Any device which generates electricity may require testing. This can be for product development, production line testing, product demonstration, commissioning of a new installation or for periodic service, maintenance or trouble shooting. Although the most common use of load banks for testing is with engine generator sets, in fact, any device which generates electricity may require a load bank for testing, service or calibration. This includes UPS, batteries, power supplies, fuel cells, solar cells, wind turbines, hydro generators, etc. A load bank provides a stable, known, controllable and relatively harmless load for these purposes. That is, if the performance of the generator is not known, it is better to evaluate the performance with a load bank than with critical facility loads. Load Bank Overview Load banks simulate the real world loads that the power source will experience. Electrical load can be broadly classified as resistive, magnetic and capacitive. In the real world, these components are mixed, as they are with a load bank, except with the load bank, full control of the components is possible. Resistive loads comprise incandescent lighting, electric heating and other loads in which electrical energy is largely converted to heat. Magnetic loads comprise motors, transformers and other devices which convert electrical energy to mechanical force. Capacitive loads comprise electronic loads. Although both AC and DC systems power similar loads, most of this discussion will involve AC systems. The most common load bank and the load bank which is suitable for general load testing is the resistive load bank. A resistive load bank converts electrical energy to heat. Within the load bank, the load is divided into discrete circuits or steps capable of stepwise, controlled application. The load bank includes a means of cooling, most commonly forced air, but also water. The load bank also includes protective sensors, circuit protection devices, instrumentation, an operator interface and a means of connection to the generator. To simulate magnetic or motor loads, an inductive load bank is added to the resistive load bank. This can take the form of an integrated, all-in-one package, or separate units. Likewise, a capacitive load bank can be added. Inductive and capacitive load banks are always used in conjunction with a resistive load bank-- there is generally no reason to use one alone. Inductive and capacitive load banks, also known collectively as reactive load banks, are only used on AC systems and result in lagging or leading power factor for inductive or capacitive loads respectively. Load Test Capacity The desired capacity of the load test is expressed in kilowatts (KW). KW corresponds directly to engine HP (.746 HP = KW) and is developed exclusively by the resistive load bank. Adding reactive load changes the total KVA of the load, but does not alter the KW or HP load. A purely resistive load bank provides a realistic and effective test of the prime mover and causes full load currents to be developed by the generator. The engine will develop full rated HP, operating pressures and temperatures, and the performance of the governor will be fully evaluated. Adding inductive load allows for the full KVA capacity of the generator to be developed for a full functional test of temperature rise, waveform quality, voltage regulator response and reactive load sharing. Voltage Low voltage AC systems are rated 120/240v, single-phase, 2 or 3 wire; 208-240/416-480/575-600vAC, 3 or 4 wire. Medium voltage systems are in the 5kV or 15kV class. DC systems can range from battery voltages of 12/24/32v, 125/250v, or 350/700v, typically. Keep in mind that the AC load banks in this catalog are generally 3-phase, 3-wire loads, meaning that a neutral is not required and that loads are applied in 3-phase balanced steps Current Current, expressed in amperes, is found by the following formula: 3ph. A= KW x1000 (Vx1.73 xp.f. ) Current must be known in order to size connection cables. Keep in mind that connection cables have a certain small resistance, and that a small voltage drop will be seen across the cable set and at the terminals of the load bank. Therefore, although the generator instrumentation may indicate 480v, the load bank instrumentation will measure the terminal voltage at the load bank, for example, 473v. KW as a Function of Voltage KW varies as the square of the voltage: therefore, in the preceding example, if the load bank terminal voltage is reduced to 473v, then the resultant KW will be 97% of the rated KW. Where did that power go? It is lost as heat in the connection cables. Low Power Factor Testing By adding an inductive load to the resistive load, lagging power factor can be obtained. Commercial loads, as well as generator sets, are rated at the nominal power factor of 0.8 lagging. This number is the cosine of the angle made between the KW and the KVA in the diagram below: kva COS PF = TAN KVA= kw = Power Factor KW KVA x KW =KVAR 2 2 KW +KVAR kvar The magnitude of inductive load required to obtain 0.8 power factor is 0.75 X the KW (1000kw + 750kvar = 1250kva at 0.8 lagging power factor). As a point of interest, 0.75 is the tangent of the aforementioned angle. Keep in mind when sizing cables that the full load current at the rated KVA must be calculated. Leading Power Factor Testing The same rationale as above applies to leading power factor, except capacitive load is added. Leading power factor testing is rare and specialized. Most engine generator sets cannot tolerate more than a very small degree of leading power factor. Portability and Site Conditions When designing a load bank rental, considerations must be given to site space, access and set up. All SOS Rental Load Banks listed herein can be networked in groups and connected in parallel to provide a total, aggregate load. It may be more workable to network 10 SOS Powerstar Load Banks to obtain 1000kw than rent a single Atlas Load Bank. Networking and Paralleling All SOS Rental Load Banks can be networked and paralleled to form larger systems. Powerstar Load Banks can only be networked with other Powerstar Load Banks. All other models can be networked and paralleled in any mix and match combination up to a maximum number of units. All control is centralized in a single operator interface. All data is likewise totalized to the operator interface. Networking is via data cables provided with the load banks. Power cables are paralleled to the power source. Continued on page 12. Fax 978-378-4693

Load Bank Rental Selection Guide Page 3 All SOS Rental Load Banks are portable units suitable for field use. Rental load banks are differentiated by capacity, voltage and frequency rating, and relative portability. All SOS Rental Load Banks are digitally controlled and network capable. Powerstar Load Banks can be networked in systems of up to 40 units, but cannot be networked to other models. All other SOS Load Banks can be networked in any combination and in any mix of models, up to a practical limit of 20 units. All SOS Rental Load Banks, except Powerstar, have data acquisition capability. Powerstar requires accessory data acquisition package. Rental Load Bank Considerations 1. Capacity required for the test: KW, power factor, Voltage 2. Rental Load Bank System Architecture: one unit or multiple networked units 3. Site conditions for the test: indoor/ outdoor, ventilation and access limitations, environmental conditions 4. Duration of test, if system is to remain set-up for long periods 5. Control requirements: local/remote, manual/automatic 6. Data acquisition requirements 7. Connection cable requirements 8. Technician/operator requirements 9. Other accessories needed Load Ranger - 1500-3000KW, 1125-2250KVAR PowerStar - 100KW Atlas - 1000KW dynamite - 400KW Magnex - 300-938KVAR Load Cube - 2500KW, 0.8 p.f. Electra - 700KW Trident - 1250-2500KW Fax 978-362-0317

PowerStar 100KW Digital Load Bank Networks to 4000KW Page 4 The STAR of Flexible Load Testing The Powerstar is a digitally controlled load bank with network capability. All control is via a hand-held touchscreen controller connected to the load bank via a supplied RS-232 network cable. The load bank includes a digital power transducer with meter displays on the touchscreen. Load is applied via a screen keypad. Any number of Powerstar Load Banks can be networked together via RS-232 cables connected from the out connector on the first unit to the in connector on the next, and then out-to-in in succession until the desired number of units are connected. All control and metering is provided from a single hand-held controller. All instrumentation values for the total network are summed and displayed on the master controller. Fan/Control Power External, 115V, 1-phase, 60Hz, 15A service, 15 cord with plug provided Capacity Detail Voltage Dual Voltage, nominal 240/480V AC, 3-phase 208-240/416-480V AC, 3-phase, 60Hz 190-220/380-460V AC 3-phase, 50Hz 110-240V AC, 1-phase, 50-60Hz Load Steps Digital load control, 5kw resolution Frequency 50 60 400Hz Duty Cycle Continuous Temp Rating 125 F max intake air temp Nominal 110 F rise Weight 125 lbs. FLA KW DETAIL 240V 480V 240V/480V 208/416V 240V, 1-ph 240 120 100 75 67 1. Control Compartment Cooling Fans (2) 2. Load Element Compartment Cooling Fans (4) 3. Load Source Connections 4. Storage Compartment for handheld controller 5. Handles (2) 6. RS-232 and 120V connectors 7. Swivel Casters (4) Fax 978-378-4693

dynamite, Electra, Atlas Digital Load Banks Networks to 10MW 1.0-0.8 pf Page 5 The POWER-HITTERS of Load Testing The dynamite, Electra, and Atlas are large capacity, high performance Portable Load Banks. Features digital controllers with network control and data acquisition capability. Operator interface is via touchscreen. Load control is via screen keypad. All electrical values display on the screen and are recorded by the system for future data retrieval. Any number of dynamite, Electra, and Atlas Load Banks can be combined for large system capacities and networked for central control and data acquisition. dynamite 34 W x 48 H x 60 D; 1,000 lbs. Electra 34 W x 79.6 H x 60 D; 1,675 lbs. Atlas 48 W x 81 H x 96 D; 2,500 lbs. Mix and Match in any combination. Add Magnex Inductive units to achieve 0.8 power factor (page 10). Electra - 700KW unit, networks to 7MW Atlas 1000KW unit, networks to 10MW Capacity Detail dynamite - 400KW unit, networks to 4MW FLA KW DETAIL Model KW (1.0pf) 240V 480V 240V/480V 208/416V 380V 240V, 1-ph dynamite 400 961 481 400 300 251 267 Electra 700 1,683 842 700 525 439 467 Atlas 1,000 2,404 1,202 1,000 750 630 667 Cooling System Model HP CFM T, Nom. T, Max. dynamite 3.0 10,500 115 F 300 F Electra 5.0 12,500 158 F 350 F Atlas 10 27,700 120 F 480 F Digital Load Step Control Nominal 5.0 kw resolution: direct enter any load value and controller will apply load within nominal 5kw resolution Digital Load Calibration Versus Voltage Controller automatically calibrates loads for reduced voltage operation. Fax 978-362-0317

Load Ranger Modular Test System Page 6 + + + + + RESISTIVE MODULE INDUCTIVE MODULE TRANSFORMER MODULE CONNECTION CABLES DIGITAL CONTROLLER Load Ranger Resistive Modules 1500 and 3000KW 240/480V, 480V, 480/600V 5KW Step Resolution Digital, Networked Load Control Data Acquisition Capability Cam-Lok and Bolt-On Connection Rugged, Outdoor Capable Trailer Capable Load Ranger Inductive Modules For Use With Resistive Module 1125 and 2250Kvar 240/480V, 480V, 480/600V 3.75KVAR Step Resolution Digital, Networked Load Control Data Acquisition Capability Cam-Lok and Bolt-On Connection Rugged, Outdoor Capable Trailer Capable Load Ranger Transformer Modules 2000 and 4000KVA Re-Connectable 13.8KV, 12.47KV, 7.2KV, 4160V Inputs To Accept Shielded Cable 480V Secondary Output Fused Switches Cam-Lok and Bolt-On Low Voltage Connections Rugged Outdoor Capable Trailer Capable Fax 978-378-4693

Load Ranger Modular Test System Page 7 + = TRAILER TRAINED TECHNICIANS BIG SOLUTIONS FOR BIG TESTING Connection Cables Digital Controllers 600v, 4/0 (400A), type W high-flex cable 50 and 100 foot lengths terminated with Cam-Lok connectors 5kV, 4/0 (280A), shielded grounded 50 and 100 foot lengths terminated with stress-cone connectors 15kV, 2/0 (225A), shielded grounded 50 and 100 foot lengths terminated with stress-cone connectors Digital, network controllers to link all elements of the load bank system to a single operator interface. Totalized data acquisition Network cables provided Automatic test software available PC compatible software available Trailer Packaged Assembly Load Ranger Systems built-up at local SOS Rental Service Center and delivered to your jobsite as a trailerized package with single points of power and control connection Technicians Service Centers are staffed with Simplex Factory Trained technicians available for system set-up, start-up, training and operation. Fax 978-362-0317

Load Cube 2500KW Digital Load Bank Networks to 2500KW 0.8 pf Page 8 The Mighty Mite of Load Testing: Big Power, Small Package The Simplex Load Cube is an ultralarge capacity, fully portable, resistive/ reactive Load Bank System intended for field use in testing, maintenance and performance proving of large generating systems. The Load Cube is rated 2500kw, 1875kvar at 400-600v commercial AC voltages. The Load Cube is typically used to test large diesel generators, turbines, paralleled generators and shipboard generators. With a purpose-built design consisting of rugged, all-welded, tubular steel frame, heavy gauge steel sides, guarded hinged doors, power-operated ventilation louvers, the Load Cube is far superior to designs which use refurbished and modified ISO shipping containers. Four-sided access allows ready service of all components and facilitates the ultra-compact design. Compact and easily transportable, the Load Cube is ideal for rental use. With a footprint of only 8 x 10 feet and a height of less than 9 feet, the Load Cube is easily transportable by conventionalheight flat bed trailer. Lifting eyes and forklift channels simplify site movement. The Load Cube utilizes digital load control for direct access of load values, block transitions, and user programmable automation. A selection of digital power meters and data acquisition software is available. Network capability allows up to 10 Load Cubes to be controlled from a single station with full system data totaling. The Simplex Load Cube represents the ultimate technology in large generator load testing performance. CAPACITY: VOLTAGE: FREQUENCY: LOAD STEPS: DUTY CYCLE: 3125KVA, 0.8 power factor; 2500KW, Resistive; 1875KVAR, Inductive Nominal, 480VAC, 3-phase, 3-wire, to 600V, 50 60 Hertz 60 Hertz, 50 Hertz available Digital load control, 10 kw, 7.5 kvar resolution. Circuits of 10 20 20 50 100 100 200 250 250 500 1000 KW 7.5 15 15 37.5 75 75 150 187.5 187.5 375 750 KVAR Continuous AMBIENT TEMP.: 125 F EXHAUST RISE: 220 F AIRFLOW: CONTROL POWER: Approx 60,000 cfm divided between two cooling fans Internal, derived from power source under load. 480-3-60VAC Control circuits at 120v via internal isolation transformer Fan motor load: 2 x 10hp, 13A Control power load: 3.0 kva, 6.25A Fax 978-378-4693

Trident Trailer Load Banks Digital Load Bank Networks to 25MW Page 9 The ROAD WARRIOR of Load Banks Self-contained and ready-to-roll, the SOS Trident Trailer Load Banks pack it on-board: dual voltage resistive load bank, cables on reels, cam-lock cable connection panel, digital-network capable control and data acquisition with remote control cables. These rugged over-the-road systems go where the big boys can t: parking garages, alleys, congested yards. Operate in all-weather conditions. Network with other Trident Trailers or with any SOS Rental Load Bank (except PowerStar) to form large systems in excess of 25MW. SOS Trident Rental Load Banks include: Resistive Load Bank, 1250kw or 2500kw Cables on reels: Up to 2000 feet of type W, 600v, 4/0 cable in 50 or 100 foot sections, and required number of generator end pigtails. Long length terminated both ends with cam-lock connectors. Pigtails terminated one end with female cam-lock, opposite end stripped Cam-Lock connection panel on trailer Digital load control, remote panel, with cables (nominal 100 ) CAPACITY: VOLTAGE: LOAD STEPS: FREQUENCY: CONTROL POWER: CONTROL: Trident 1250: 1250KW, 1.0 power factor Trident 2500: 2500KW, 1.0 power factor 240/480/240-1VAC or 480/600VAC, 50/60 Hertz 5KW resolution 60 Hertz, 50 Hertz Heavy duty tandem axle trailer with ball or pintle hitch and electric brakes (requires electric brake controller in towing vehicle) Selectable: Internal/External Digital, network capable, with totalizing digital data acquisition Fax 978-362-0317

Magnex Inductive Load Banks Digital Load Bank Networks to Resistive Load Banks Page 10 The Magnetic Mate for SOS Resistive Load Banks for 0.8 Power Factor Testing The Magnex is designed to be used with the SOS dynamite, Electra, Atlas and Trident Load Banks or with an existing resistive load bank. Connects in parallel with resistive load bank. Networks to SOS Resistive Load Bank for combined control and totalized data acquisition, including system calculation of power factor and KVA. Can also be operated from local, analog control panel when used with existing resistive load bank. CAM-Lock cable connectors in side well. Remote control connector in side well and 25 of remote control cable (connects to communications port on SOS Resistive Load Bank). CAPACITY: Magnex 300-300KVAR, use with dynamite 400 Magnex 525-525KVAR, use with Electra 700 Magnex 750-750KVAR, use with Atlas 1000 Magnex 938-938KVAR, use with Trident (use 2 with Trident 2500) VOLTAGE: LOAD STEPS: CONTROL POWER: CONTROL: 240/480VAC or 480/600VAC 3.75KVAR resolution Selectable: Internal/External Digital, network capable, with totalizing digital data acquisition Fax 978-378-4693

Specialty Load Banks Page 11 Didn t find what you need? Look below. Swift-e Swift-e 15kw, 120/240v, single-phase for testing marine, residential and RV generators Magnex-c Magnex-c, 500kvar, 480v, capacitive load bank, for use with resistive load bank to obtain leading power factor Megatron Megatron, 400hz, resistive/ inductive load bank, 208Y/120v, 416/240v Watt-Muncher Watt-Muncher, 12/24vDC, 150A load bank for testing batteries, power supplies Build-To-Rent Build-To-Rent: you imagine it, we design and build it and rent it to you (or you can buy, of course) DC Load Banks DC load banks, 125/250/350/700vDC Water-Cooled Water-Cooled Load Banks, 400kw. 500kw, 208v, 240v, 416v, 480v Fax 978-362-0317

Rental Accessories Page 12 Rental Connection Cables 600v, 4/0 (400A), type W high-flex cable 50 and 100 foot lengths Terminated with Cam-Lok connectors 5kV, 4/0 (280A), shielded grounded 50 and 100 foot lengths Terminated with stress-cone connectors 15kV, 2/0 (225A), shielded grounded 50 and 100 foot lengths Terminated with stress-cone connectors Supplied as bulk cable or on reels Digital Controllers and Data Acquisition Data acquisition package for Powerstar load bank system Automatic test software PC compatible test software Trailer Packaging Systems built-up at local SOS Rental Service Center and delivered to your jobsite as a trailerized package with single points of power and control connection Technicians Service Centers are staffed with Simplex Factory Trained technicians available for system set-up, start-up, training and operation. Delivery and Pickup Your load bank rental system delivered to your jobsite and picked up by SOS. Fundamentals of Load Bank Rentals cont d from page 2 Sizing and Running Cables Rental cables listed in this catalog should be operated at approximately 85% maximum of their open air current rating. Ampere ratings listed are the NEC free air ratings. Cables listed are suitable for wet or dry aboveground use and should be run in a well ventilated area. Keep cable splice points out of water. 3-phase cables must be of absolutely equal length, especially when multiple cables are run per phase. Run 3-phase cables in 3-phase groupings, ideally arrayed in a triangle, but at least side-by-side. Never separate phases into A-B-C clusters as this can lead to electromagnetically induced current imbalances, voltage drops and cable overheating. Ground Cables Run at least 33% ground capacity. Connect ground cables to ground terminals or ground bar in the load bank. Connect the other end to the generator ground. Be sure that the generator is solidly grounded to earth ground. Avoid multiple earth grounds as this can lead to potential differences among the ground points with resultant circulating ground currents. Heat and Airflow The user needs to appreciate how hot a load bank gets and how much hot air is produced. As a guide, temp rise (F) = KW x 3000/CFM. Load banks are heat producing devices and must be ventilated. Observe the CFM capacity of the load bank and be certain that equivalent air intake is provided. If operated indoors, be cautious to prevent recirculation of exhaust air and observe ambient temperatures. Do not operate vertical airflow load banks under a close ceiling. Maintain a max ambient of no more than 125 F. Load banks greater than 100kw (Powerstar 100) are ideally operated outdoors and extreme caution should be exercised in the 100-700kw range. Above 700kw, an indoor space would have to be voluminous and well ventilated. Indoors, note the presence of sprinkler heads as the load bank WILL ACTIVATE sprinklers very quickly. Outdoors, be observant of adjacent equipment, buildings, plantings. Operate in an area with clear sky above. Avoid putting the load bank in a virtual pit by surrounding it with tall walls or buildings. Space multiple load banks 4-6 feet apart, greater with larger units. Safety Load banks are not inherently dangerous but there are dangers that exist with operation of load banks. This is a technical, industrial product and should only be set-up and operated by trained, technical personnel who are specifically authorized by the renter. Be certain that all equipment is properly grounded. Carefully check cables for wear and tear, insulation damage. Check all camlock connectors that connections are made sound and tight including both connector mating (the connector twist-tightens) and the cable within the connector. Be certain that cables are phased correctly. A circuit breaker or fuse set is required at the power source sized appropriately for the conductor run. Be sure to run adequate ampacity of cables. Check that generator voltage corresponds to load bank voltage. Check correct airflow direction and if it is necessary to reverse cooling fan direction, allow fan to fully stop before reversing. Provide the CFM required at an ambient not to exceed 125 F. Be observant of airflow restrictions and recirculation of airflow. Be careful that foreign objects are not drawn into cooling intakes. Do not operate indoor load banks in the rain. Observe common and accepted practices when operated high voltage electrical equipment. Note that load bank exterior, exhaust screens and other sheet metal parts can be very hot. Wear hearing protection as required. Fax 978-378-4693