SPCC Plan - Calculation Guidance



Similar documents
Chapter 4 Secondary Containment and Impracticability

1. Site plans assist the Fire Department to determine where a potential spill can be contained. The detailed site plan shall include the following:

VOLUME of Rectangular Prisms Volume is the measure of occupied by a solid region.

Perimeter, Area, and Volume

Site Development Information Worksheet for single family residential development

Basic Math for the Small Public Water Systems Operator

Table 4.9 Storm Drain Inlet Protetion Applicable for

WEIGHTS AND MEASURES. Linear Measure. 1 Foot12 inches. 1 Yard 3 feet - 36 inches. 1 Rod 5 1/2 yards /2 feet

Area of a triangle: The area of a triangle can be found with the following formula: in

Area of Parallelograms (pages )

Show that when a circle is inscribed inside a square the diameter of the circle is the same length as the side of the square.

Construction Site Inspection Checklist for OHC By making use of some simple Best Management Practices (BMPs) a construction site operator can

CHAPTER 11 STORM DRAINAGE

OREGON FIRE CODE Interpretations and Technical Advisories

Appendix 3 Water-Harvesting Earthworks Calculations

Solids. Objective A: Volume of a Solids

The following definitions apply with regard to requirements specified in this document:

STANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

ACTIVITY: Finding a Formula Experimentally. Work with a partner. Use a paper cup that is shaped like a cone.

Spill Prevention, Control and Countermeasure (SPCC)

DIMENSIONAL ANALYSIS #2

Sanitary Sewer Overflow (SSO) Incident Report Form

RAINWATER HARVESTING FOR DRYLANDS - VOLUME 1. By Brad Lancaster, Appendix 3. Water-Harvesting Calculations

Geometry Notes VOLUME AND SURFACE AREA

CHAPTER 2 HYDRAULICS OF SEWERS

Area is a measure of how much space is occupied by a figure. 1cm 1cm

Index. protection. excavated drop inlet protection (Temporary) Block and gravel inlet Protection (Temporary)

Area and Perimeter. Name: Class: Date: Short Answer

City of Shelbyville Site Inspection Checklist

Area of a triangle: The area of a triangle can be found with the following formula: You can see why this works with the following diagrams:

MODULE IV Secondary Containment, Oil Spill Control & Spill Prediction

Teacher Page Key. Geometry / Day # 13 Composite Figures 45 Min.

SPCC Rule Review. Spill Prevention Control & Countermeasures NON-TRANSPORTATION RELATED ONSHORE AND OFFSHORE FACILITIES

Practice Tests Answer Keys

CITY OF WASHINGTON SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

Kurt Wilson Louisiana Dept. of Environmental Quality Business & Community Outreach Division Small Business/Small Community Assistance Program

Finding Volume of Rectangular Prisms

Improper storage of potential pollutants will increase the risk of water pollution that may occur because of spills.

2. A painted 2 x 2 x 2 cube is cut into 8 unit cubes. What fraction of the total surface area of the 8 small cubes is painted?

SPCC for Food Services

IAC 7/2/08 Agriculture and Land Stewardship[21] Ch 44, p.1

Elev. A = , Elev. B = , horizontal distance = 1625 feet a. 7.7 b..077 c d. 1.28

Appendix 3 Water-Harvesting Calculations

Homeowner s Guide Foundation Water PenetrationTips TIPS TO IDENTIFY WATER PENETRATION PROBLEMS / CRACKING BASEMENTS

Steel Tank Institute AST Inspections. Dana Schmidt, PE STI/SPFA

Spill Prevention, Control, and Countermeasures (SPCC) Regulations Update

Tanks: What's in store?

B = = 84 in2. Since h = 20 in then the total volume is. V = = 1680 in 3

Solving Geometric Applications

Spill Prevention, Control and Countermeasure (SPCC) Rule

Riprap-lined Swale (RS)

Geometry Notes PERIMETER AND AREA

Cylinder Volume Lesson Plan

ACTIVITY NAME. Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas

GCSE Exam Questions on Volume Question 1. (AQA June 2003 Intermediate Paper 2 Calculator OK) A large carton contains 4 litres of orange juice.

Area of Parallelograms, Triangles, and Trapezoids (pages )

1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.

Above-Ground Fuel Storage Systems

Geometry and Measurement

OIL STORAGE REQUIREMENTS OF THE SPCC REGULATIONS. Christopher J. Ecsedy, P.E. Fuss & O'Neill, Inc. 146 Hartford Road Manchester, CT 06040

SURFACE AREA AND VOLUME

Shop Fabricated Aboveground Tank Construction Standards

SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y

Spill Prevention, Control and Countermeasures (SPCC) 40 CFR 112. For Bulk Facilities

Cast Iron Radiator Heating Capacity Guide

Follow the Drop. Activity Overview Students observe and collect information about water runoff on their school property. Objective Students will:

APPENDIX F. RESIDENTIAL WATER QUALITY PLAN: ALLOWABLE BMP OPTIONS

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

C.3 Workshop Track 2: Sizing Calculations and Design Considerations for LID Treatment Measures

Area & Volume. 1. Surface Area to Volume Ratio

CH. 2 LOADS ON BUILDINGS

Pizza! Pizza! Assessment

ORDINANCE NO

APPLICATIONS AND MODELING WITH QUADRATIC EQUATIONS

The following definitions apply with regard to requirements specified in this document:

Scour and Scour Protection

Maximum Floor Area and Maximum Development Area

Area, Perimeter, Volume and Pythagorean Theorem Assessment

Suffolk County Department of Health Services. Division of Environmental Quality

Secondary Containment: Regulations & BMPs. Beth Powell Vice-President and General Manager New Pig Energy bethp@newpigenergy.com

Planning and Building Hay Barns that Work

Mandatory Part 1.4 BUILD OVER OR NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

Answer Key for the Review Packet for Exam #3

SECTION INLETS INLET LOCATIONS

MATHEMATICS FOR ENGINEERING BASIC ALGEBRA

Imperial Length Measurements

ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN

CHAPTER 11 STORM DRAINAGE

Outdoor Liquid Container Storage

Natural Resources Conservation Authority Guidelines for Secondary Containment of Hazardous Liquids stored Above-ground

E4055. Quiz. Soil Classification. Name: SOIL CLASSIFICATION QUESTIONS

Grade 8 FCAT 2.0 Mathematics Sample Questions

Residential Deck Safety, Construction, and Repair

Transcription:

SPCC Plan - Calculation Guidance The following example compares two different design criteria: one based on the volume of the tank and one based on precipitation. Scenario: A 20,000-gallon horizontal tank is placed within an engineered secondary containment structure, such as a concrete dike. The tank is 35 feet long by 10 feet in diameter. The secondary containment area provides a 5-foot buffer on all sides (i.e. dike dimensions are 45 feet x 20 feet). 20,000 20 ft gallons Height:? 45 ft Given the dike footprint, we want to determine the wall height necessary to provide sufficient freeboard for precipitation, based on (1) the tank storage capacity (2) actual precipitation data. Several storm events in the recent past caused precipitation in amounts between 3.6 and 4.0 inches at this location, although greater amounts have also been reported in the past. Note: The factor for converting cubic feet to gallons is 7.48 gallons/ft 3 1. Calculation of secondary containment capacity, based on a design criterion of 110%*** of tank storage capacity: Containment surface area = 45 ft x 20 ft = 900 ft 2 Tank volume, based on 100% of tank capacity = 20,000 gallons Tank volume, in cubic feet = 20,000 gallons / 7.48 gallons/ft 3 = 2,674 ft 3 Wall height that would contain the tank s volume = 2,674 ft 3 / 900 ft 2 = 2.97 ft Containment capacity with freeboard, based on 110% of tank capacity = 22,000 gallons Containment capacity, in cubic feet = 22,000 gallons / 7.48 gallons/ft 3 = 2,941 ft 3 Wall height equivalent to 110% of storage capacity = 2,941 ft 3 / 900 ft 2 = 3.27 feet Height of freeboard = 3.27 ft - 2.97 ft = 0.3 ft = 3.6 inches Therefore, a dike design based on a criterion of 110% of tank capacity provides a dike wall height of 3.27 feet. 2. Calculation of secondary containment capacity, based on rainfall*** criterion: After a review of historical precipitation data for the vicinity of the facility, it was determined that a 4.5 inch rain event is the most reasonable design criterion for this diked area. Containment surface area = 45 ft x 20 ft = 900 ft 2 Tank volume, based on 100% of tank capacity = 20,000 gallons Tank volume, in cubic feet = 20,000 gallons / 7.48 gallons/ft 3 = 2,674 ft 3 Wall height that would contain the tank s volume = 2,674 ft 3 / 900 ft 2 = 2.97 ft The height of the dike would need to be 3.35 feet (2.97 ft + 4.5 in). 4.5 inches / 12 inches =.375 ft + 2.97 ft = 3.35 ft Therefore, a dike design based on a 4.5 inch rain event provides a dike wall height of 3.35, or 0.9 inch higher than calculated using the 110% criterion.

Sample secondary containment calculations for multiple tanks in a containment area. Scenario: A 60 ft x 36 ft concrete dike surrounds one 20,000-gallon horizontal tank (10 ft diameter and 35 ft length) and two 10,000-gallon vertical tanks (each 10 ft diameter and 15 ft height). The dike walls are 18 inches (1.5 feet) tall. The SPCC Plan states that secondary containment is designed to hold 112% of the volume of the largest container. 2 @ 10,000 gallons 1.5 ft 20,000 gallons 36 ft 60 ft Note: The volume displaced by a cylindrical vertical tank is the tank volume within the containment structure and is equal to the tank footprint multiplied by height of the concrete dike. The tank footprint is equal to D2/4, where D is the tank diameter. 1. Calculate total dike capacity: Total capacity of the concrete dike = length x width x height = 60 ft x 36 ft x 1.5 ft = 3,240 ft 3 = 24,235 gallons 2. Calculate net dike capacity, considering displacement from other tanks within the dike: The total capacity of the concrete dike is reduced by the volume displaced by other tanks inside the containment structure. The displacement is: = number of tanks x footprint x height of dike wall = 2 x (10 ft) 2 /4 x 1.5 ft = 235.6 ft 3 = 1,762 gallons The net dike capacity (i.e. the volume that would be available in the event of a failure of the largest tank within the dike) is: = Total volume - tank displacement = 24,235-1,762 = 22,473 gallons = 3,004 ft 3 3. Calculate the amount of available freeboard provided by the dike, given the net dike capacity: The available freeboard volume is: = Net dike capacity - volume of largest tank within the dike = 22,473-20,000 = 2,473 gallons = 331 ft 3 This is equivalent, expressed in terms of the capacity of the largest tank, to: = Net dike capacity / volume of largest tank within the dike = 22,473 / 20,000 = 112% This available freeboard volume provides a freeboard height: = Available freeboard volume / dike surface area = 331 ft 3 / (60 ft x 36 ft) = 0.15 ft 1.8 in Therefore, this dike provides sufficient freeboard for 1.8 inches of precipitation.

The following guidance is offered as assistance in calculating the volume in gallons of capacity for earthen berms used for secondary containment structures. 1. Calculate total berm capacity: Total capacity of the berm = length (top of berm) x width (top of berm) x height (at lowest point) Top of berm: 60 ft x 36 ft x 1.5 ft = 3,240 ft 3 = 24,235 gallons (top) Bottom of berm: 54 ft x 30 ft x 1.5 ft = 2,430 ft 3 = 18,176 gallons (bottom) To determine average capacity: 24,235 + 18,176 divided by 2 = 21,205 gallons 2. Calculate net dike capacity, considering displacement from other tanks within the berm: Refer to and follow the instructions provided earlier in this guidance document. 3. Calculate the amount of available freeboard provided, given the net berm capacity: Refer to and follow the instructions provided earlier in this guidance document.

The following guidance is offered as assistance in calculating the volume in gallons of capacity for secondary containment structures and tanks. Volume Formulas and Examples: Floor capacity: Length x Width x Height x 7.48 = Gallons of capacity 20 x 12 x 2 x 7.48 = 3,590 gallons Conversions 1 =.083 2 =.167 3 =.25 4 =.333 5 =.417 6 =.5 7 =.583 8 =.667 9 =.75 10 =.833 11 =.917 12 =1 Tank capacity (round): Tank capacity (cone): Sloped Floor: Sloped Floor:.7854 x Diameter x Diameter x Height x 7.48 = Gallons of capacity.7854 x 6 x 6 x 12 x 7.48 = 2,537 gallons.252 x Diameter x Diameter x Height x 7.48 = Gallons of capacity.252 x 8 x 8 x 2 x 7.48 = 241 gallons (Pyramid).333 x Length x Width x Height x 7.48 = Gallons capacity.333 x 30 x 16 x 6 x 7.48 = 597 gallons (Trough).333 x Length x Width x Height x 7.48 = Gallons capacity.5 x 30 x 16 x 6 x 7.48 = 897 gallons *** Additional Considerations for Sufficient Freeboard EPA recognizes that a 110 percent of storage tank capacity rule of thumb may be a potentially acceptable design criterion in many situations, and that aboveground storage tank regulations in many states require that secondary containment be sized to contain at least 110 percent of the volume of the largest tank. However, in some areas, 110 percent of storage tank capacity may not provide enough volume to contain precipitation from storm events. Some states require that facilities consider storm events when designing secondary containment structures, and in certain cases these requirements translate to more stringent sizing criteria than the 110 percent rule of thumb. Other important factors may be considered in determining necessary secondary containment capacity. According to practices recommended by industry groups such as the American Petroleum Institute (API), these factors include: Local precipitation conditions (rainfall and/or snowfall) Height of the existing dike wall Size of container Safety considerations Frequency of dike drainage and inspection Local precipitation data is available from the National Weather Service at: http://www.nws.noaa.gov/oh/hdsc/currentpf.htm#n2

SPCC Plan - Calculation Worksheet Revised: September 15, 2011 myspcc Guidance. Photocopy this form or download from the website.