DWDM SFP Series. Power budget* (note2) Laser



Similar documents
DWDM SFP Series. Power budget* (note2) Laser

155Mbps DFB SFP Optical Transceiver, 120km Reach

Dual Fiber SFP Series

SFP-SX with DOM 1.25Gb/s Multi-Mode SFP Transceiver 1000BASE-SX Gb/s Fiber Channel

DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver

How To Connect A 10Gbps Sfp+ Bi-Directional Transceiver To A Single Mode Fiber With A Single Power Cell (Sfp+) To A Power Cell With A Power Source (Sf) (Sfl) (

4.25Gbps SFP Optical Transceiver, 30km Reach

8.5Gb/s SFP+ Fibre Channel Optical Transceiver

LONGLINE 10Gbps 10km SFP+ Optical Transceiver

SFP+ DWDM Dual LC 10G SMF 40km Transceiver. Features. Applications APPLIED OPTOELECTRONICS, INC. A7ELXDxxEDMA0609

2.488Gbps Compact Bi-Di SFP Transceiver, 20km Reach 1490nm TX / 1310 nm RX

Product Specification. OC-12 LR-1/STM L-4.1 RoHS Compliant Pluggable SFP Transceiver. FTLF1422P1xTL

155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX

SFP+ LR 10G Ethernet 10km SFP+ Transceiver 10GBASE-LR / 10BBASE-LW

SFP-GIG-SX 1000BASE-SX, Jusqu à 550 mètres de distance opérationnelle, Longueur d onde Laser 850nm, Fibre Multimode (MMF), SFP Optique Insérable

SFP-TX 1000BASE-T SFP Transceiver 10/100/1000M SFP Transceiver

GPON OLT Optical Transceiver SFP Module RTXM Features

Part No. Data Rate Wavelength Interface Temp. DDMI

1.25Gbps GBIC Optical Transceiver, 20km Reach

10Gbps XFP Bi-Directional Transceiver, 10km Reach 1270/1330nm TX / 1330/1270 nm RX

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

Product Specification. RoHS-6 Compliant 10Gb/s 850nm Multimode Datacom XFP Optical Transceiver FTLX8512D3BCL

10/100/1000BASE-T SFP Transceiver

LONGLINE 2km XFP Optical Transceiver

Product Specification 10Gb/s BIDI SFP+ Transceiver

1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver

XFP Optical Receiver, 80km Reach

RoHS Compliant Copper Small Form Factor Pluggable (SFP) Transceiver for Gigabit Ethernet

Intel Ethernet SFP+ Optics

EPON ONU Optical Transceiver SFF Module

LONGLINE 40km XFP Optical Transceiver

Methode Electronics. DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT.

1250Mbps Gigabit Interface Converters (GBIC) Transceiver Module for Gigabit Ethernet

Fast Ethernet 100BASE-LX10 SFP Single Mode Transceivers with Digital Diagnostics

10GBASE-LR XFP Optical Transceiver AXM752

10GBASE-SR XFP Optical Transceiver AXM751

LONGLINE QSFP+ SR4. Features. Applications. Description. Page 1 of 13

10/100BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 100 Mbps Fast Ethernet. Features. Application

Produto: 1.25Gbps SFP Bi-Directional Transceiver, 10km Reach (1310nm TX/1550nm RX) Modelo: V7-WDM-0210AD Documentação: Técnica/Datasheet

10GBASE -LRM, 220m Reach GX LRMC

X2 LR Optical Transponder, 10Km Reach

Product Specification. 1000BASE-T RoHS Compliant Copper SFP Transceiver FCLF8520P2BTL / FCLF8521P2BTL / FCLF8522P2BTL

Modultech MT-XDFx-xx192-08(04)CD 80 (40) km DWDM XFP module with built-in FEC wrapper Description

Product Specification ps/nm (~200km) DWDM XFP Optical Transceiver FTLX4213x3xxxx

SFP Copper Transceiver 10/100/1000Base-T

SO-CFP-ER-DWDM. CFP, 103/112 Gbps, DWDM tunable, SM, DDM, 20km SO-CFP-ER4-DWDM OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

GBIC CWDM 40km Part no:

1000BASE-BX-OLT Transceiver

155Mbps ATM-Single Mode Transceiver

SO-QSFP28-LR4. QSFP, 100GBASE-LR, SM, DDM, 10km, LC SO-QSFP28-LR4 OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

PART NUMBER INPUT/OUTPUT SIGNAL DETECT VOLTAGE TEMPERATURE

RoHS compliant 1310 nm multi-mode Transceiver (2 km) 1x9, ST Duplex Plastic Connector, 3.3 V 155 Mbps ATM/ Fast Ethernet

Methode Electronics. DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly.

Cisco SFP Optics for Gigabit Ethernet Applications

Prisma IP 10 GbE VOD Line Card

Application Note 5016

Dispersion penalty test 1550 Serial

HARTING mcon 1000 Introduction and features

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

HDO700 P FIBRE OPTIC TRANSMITTER

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

BF15U REV DESCRIPTION DATE APPROVED 2 Preliminary 1/7/2016 RAS/MF

HARTING econ 3000 Introduction and features

Photolink- Fiber Optic Receiver PLR135/T1

RealSSD Embedded USB Mass Storage Drive MTFDCAE001SAF, MTFDCAE002SAF, MTFDCAE004SAF, MTFDCAE008SAF

OM2210 Coherent Receiver Calibration Source OM2210 Datasheet

SFP Transceiver Specifications

Ixia Net Optics 10G Regen Tap

Gigabit Ethernet Copper-to-Fiber Converters

3G-SDI/HD-SDI/SD-SDI Electric to Optical Converter EO3G-200

Enabling the Business Continuity & Change the way business communicates

BROCADE OPTICS FAMILY

1000 BASE-X SFP. Key Features DATA SHEET HIGHLIGHTS 1000BASE-SX 1000BASE-LX 1000BASE-ZX 1000BASE BX-D*

Wideband Driver Amplifiers

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

Serial 12.5 Gbaud, 10 km SMF Link with Clock and Data Recovery IC

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters

Golden test for dispersion penalty 1550 Serial

DS1621 Digital Thermometer and Thermostat

DS1621 Digital Thermometer and Thermostat

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

Cisco Enhanced High-Speed WAN Interface Cards

Features. Dimensions

Model GS Port Node 1 GHz with 40/52 MHz split

Tools for Building a Better Network

Features. Dimensions

Rayson. Bluetooth Module

10G CWDM Conversion Technology

EM316T1E1-XY. Features

EDR-G903 Series. Industrial Gigabit Firewall/VPN secure router. Introduction. Specifications. Industrial Ethernet Solutions

G-TAP A Series // Data Sheet

Features. Dimensions

Introduction to Optical Link Design

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

DVI Extender via 4 fiber channel LC Duplex Connector Extends DVI connection up to 500 meters

8 Gbps CMOS interface for parallel fiber-optic interconnects

Transcription:

EOLS-1624-XXD Series SFP Single-Mode for DWDM Application Duplex SFP Transceiver Digital Diagnostic Function RoHS6 Compliant Features Operating Data Rate up to 2.5Gbps Available in all C-Band Wavelengths on the 100GHz DWDM ITU Grid Single 3.3V Power Supply and TTL Logic Interface Hot-Pluggable SFP Footprint Duplex LC Connector Interface Compliant with Class 1 FDA and IEC60825-1 Laser Safety Compliant with SFP MSA Compliant with SFF-8472 Operating Case Temperature: Standard: 0 to 70 C Extended: -5 to 70 C Applications Amplified DWDM networks Ring topologies with fixed and reconfigurable OADMs Fast Ethernet, Giga Ethernet Fiber Channel Ordering Information Part No. Data Rate Laser Power budget* (note2) Interface Temperature EOLS-1624-17XX *(note1) D 2.5GMbps DWDM DFB 17dB LC Standard EOLS-1624-17XX *(note1) DI 2.5GMbps DWDM DFB 17dB LC Extended EOLS-1624-29XX *(note1) D 2.5GMbps DWDM DFB 29dB LC Standard EOLS-1624-29XX *(note1) DI 2.5GMbps DWDM DFB 29dB LC Extended EOLS-1624-32XX *(note1) D 2.5GMbps DWDM DFB 32dB LC Standard EOLS-1624-32XX *(note1) DI 2.5GMbps DWDM DFB 32dB LC Extended Note1: XX refers to DWDM Wavelength range as ITU-T specified, please refer the following table for detailed center wavelength information. Note2: The power budget which is guaranteed. Page 1 of 14

XX- Channel refers to the following table: *Channel Part NO. Frequency (THz) Center Wavelength (nm) (XX) 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 EOLS-1624- X15D EOLS-1624- X15DI 191.5 1565.50 EOLS-1624- X * 16D EOLS-1624- X * 16DI 191.6 1564.68 EOLS-1624- X * 17D EOLS-1624- X * 17DI 191.7 1563.86 EOLS-1624- X * 18D EOLS-1624- X * 18DI 191.8 1563.05 EOLS-1624- X * 19D EOLS-1624- X * 19DI 191.9 1562.23 EOLS-1624- X * 20D EOLS-1624- X * 20DI 192.0 1561.42 EOLS-1624- X * 21D EOLS-1624- X * 21DI 192.1 1560.61 EOLS-1624- X * 22D EOLS-1624- X * 22DI 192.2 1559.79 EOLS-1624- X * 23D EOLS-1624- X * 23DI 192.3 1558.98 EOLS-1624- X * 24D EOLS-1624- X * 24DI 192.4 1558.17 EOLS-1624- X * 25D EOLS-1624- X * 25DI 192.5 1557.36 EOLS-1624- X * 26D EOLS-1624- X * 26DI 192.6 1556.55 EOLS-1624- X * 27D EOLS-1624- X * 27DI 192.7 1555.75 EOLS-1624- X * 28D EOLS-1624- X * 28DI 192.8 1554.94 EOLS-1624- X * 29D EOLS-1624- X * 29DI 192.9 1554.13 EOLS-1624- X * 30D EOLS-1624- X * 30DI 193.0 1553.33 EOLS-1624- X * 31D EOLS-1624- X * 31DI 193.1 1552.52 EOLS-1624- X * 32D EOLS-1624- X * 32DI 193.2 1551.72 EOLS-1624- X * 33D EOLS-1624- X * 33DI 193.3 1550.92 EOLS-1624- X * 34D EOLS-1624- X * 34DI 193.4 1550.12 Page 2 of 14

35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 EOLS-1624- X * 35D EOLS-1624- X * 35DI 193.5 1549.32 EOLS-1624- X * 36D EOLS-1624- X * 36DI 193.6 1548.51 EOLS-1624- X * 37D EOLS-1624- X * 37DI 193.7 1547.72 EOLS-1624- X * 38D EOLS-1624- X * 38DI 193.8 1546.92 EOLS-1624- X * 39D EOLS-1624- X * 39DI 193.9 1546.12 EOLS-1624- X * 40D EOLS-1624- X * 40DI 194.0 1545.32 EOLS-1624- X * 41D EOLS-1624- X * 41DI 194.1 1544.53 EOLS-1624- X * 42D EOLS-1624- X * 42DI 194.2 1543.73 EOLS-1624- X * 43D EOLS-1624- X * 43DI 194.3 1542.94 EOLS-1624- X * 44D EOLS-1624- X * 44DI 194.4 1542.14 EOLS-1624- X * 45D EOLS-1624- X * 45DI 194.5 1541.35 EOLS-1624- X * 46D EOLS-1624- X * 46DI 194.6 1540.56 EOLS-1624- X * 47D EOLS-1624- X * 47DI 194.7 1539.77 EOLS-1624- X * 48D EOLS-1624- X * 48DI 194.8 1538.98 EOLS-1624- X * 49D EOLS-1624- X * 49DI 194.9 1538.19 EOLS-1624- X * 50D EOLS-1624- X * 50DI 195.0 1537.40 EOLS-1624- X * 51D EOLS-1624- X * 51DI 195.1 1536.61 EOLS-1624- X * 52D EOLS-1624- X * 52DI 195.2 1535.82 EOLS-1624- X * 53D EOLS-1624- X * 53DI 195.3 1535.04 EOLS-1624- X * 54D EOLS-1624- X * 54DI 195.4 1534.25 EOLS-1624- X * 55D EOLS-1624- X * 195.5 1533.47 55DI 56 EOLS-1624- X * 56D 195.6 1532.68 Page 3 of 14

57 58 59 60 61 EOLS-1624- X * 56DI EOLS-1624- X * 57D EOLS-1624- X * 57DI EOLS-1624- X * 58D EOLS-1624- X * 58DI EOLS-1624- X * 59D EOLS-1624- X * 59DI EOLS-1624- X * 60D EOLS-1624- X * 60DI EOLS-1624- X * 61D EOLS-1624- X * 61DI 195.7 1531.90 195.8 1531.12 195.9 1530.33 196.0 1529.55 196.1 1528.77 *: X refers to the DWDM Power budget(17 29 32). Please contact EOPTOLINK to confirm whether the wavelength is available. Regulatory Compliance Product Certificate Certificate Number Applicable Standard EN 60950-1:2006+A11+A1+A12 TUV UL R50135086 E317337 EMC CE AE 50135430 0001 CB FCC JPTUV-024038-M1 EN 60825-1:2007 EN 60825-2:2004+A1+A2 UL 60950-1 CSA C22.2 No. 60950-1-07 EN 55022:2006 EN 55024:1998+A1+A2 IEC 60825-2 IEC 60950-1 WTF13F0503735E 47 CFR PART 15 OCT., 2010 WTF13F0503732E 47 CFR PART 15 OCT., 2010 FDA 1230816-000 CDRH 1040.10 ROHS RLSZF00163462 2011/65/EU Product Description The EOLS-1624-XXD series single mode transceiver is small form factor pluggable module for duplex optical data communications. This module is designed for single mode fiber and operates at a nominal DWDM wavelength from 1528.77nm to 1565.50nm as specified by the ITU-T. It is designed to deploy in the DWDM networking equipment in metropolitan access and core networks. It is with the SFP 20-pin connector to allow hot plug capability. The transmitter section uses a DWDM multiple quantum well DFB laser and is a class 1 laser compliant according to International Safety Standard IEC-60825. The EOLS-1624-XXD series are designed to be compliant with SFF-8472 Multi-Source Agreement (MSA). Page 4 of 14

Absolute Maximum Ratings* note3 Parameter Symbol Min. Max. Unit Storage Temperature T S -40 +85 C Supply Voltage V CC -0.5 3.6 V Operating Relative Humidity - 95 % Note3:Exceeding any one of these values may destroy the device permanently. Recommended Operating Conditions Parameter Symbol Min. Typical Max. Unit Operating Case Temperature T c EOLS-1624-XXD 0 - +70 EOLS-1624-XXDI -5 - +70 Power Supply Voltage Vcc 3.15 3.3 3.45 V Power Supply Current Icc - - 450 ma Date Rate 2.5G bps Performance Specifications - Electrical Parameter Symbol Min. Typ. Max Unit Notes Transmitter CML AC coupled Vin 400 1600 mvpp Inputs(Differential) inputs Input Impedance (Differential) TX_Dis Zin 85 100 115 ohm Disable 2 Vcc Enable 0 0.8 TX_FAULT Fault 2 Vcc Normal 0 0.8 V Receiver CML Outputs (Differential) Vout 400 800 1200 mvpp Output Impedance (Differential) RX_LOS MOD_DEF ( 0:2 ) Zout 85 100 115 ohm LOS 2 Vcc V Normal 0 0.8 V Performance Specifications Optical VoH 2.5 V VoL 0 0.8 V V C Rin > 100 kohm @ DC AC coupled outputs (DWDM DFB and PIN/TIA, 17dB Power Budget at Least) Parameter Symbol Min. Typical Max. Unit Data Rate 2.5G bps Transmitter Page 5 of 14

Page 6 of 14 Center Wavelength λ 1528 1564 nm Spectral Width (-20dB) λ 0.3 nm Side Mode Suppression Ratio SMSR 30 db Channel Spacing f 100 GHz Deviation From Central Frequency@EOL -12 12 GHz Average Output Power* (note5) Pout 0 5 dbm Average Launch Power (Tx: OFF) Poff -45 dbm Extinction Ratio* (note6) ER 8.2 db Rise/Fall Time(20%~80%) tr/tf 150 ps Output Optical Eye* (note6) Compatible with IEEE 802.3* (note8) TX_Disable Assert Time t_off 10 us Pout@TX Disable Asserted Pout -45 dbm Relative Intensity Noise RIN -135 db/hz Receiver Center Wavelength λ 1528 1664 nm Receiver Sensitivity* (note7) Pmin -17 dbm Receiver Overload Pmax -3 dbm LOS De-Assert LOSD -19 dbm LOS Assert LOSA -42 dbm LOS Hysteresis* (note9) 0.5 db (DWDM DFB and APD, 29dB Power Budget at Least) Parameter Symbol Min. Typical Max. Unit Data Rate 2.5G bps Transmitter Center Wavelength λ 1528 1564 nm Spectral Width (-20dB) λ 0.3 nm Side Mode Suppression Ratio SMSR 30 db Channel Spacing f 100 GHz Deviation From Central Frequency@EOL -12 12 GHz Average Output Power* (note5) Pout 0 5 dbm Average Launch Power (Tx: OFF) Poff -45 dbm Extinction Ratio* (note6) ER 8.2 db Rise/Fall Time(20%~80%) tr/tf 150 ps Output Optical Eye* (note6) Compatible with IEEE 802.3* (note8) TX_Disable Assert Time t_off 10 us Pout@TX Disable Asserted Pout -45 dbm Relative Intensity Noise RIN -135 db/hz Receiver Center Wavelength λ 1528 1664 nm Receiver Sensitivity* (note7) Pmin -29 dbm Receiver Overload Pmax -9 dbm LOS De-Assert LOSD -30 dbm

LOS Assert LOSA -45 dbm LOS Hysteresis* (note9) 0.5 db (DWDM DFB and APD, 32dB Power Budget at Least) Parameter Symbol Min. Typical Max. Unit Data Rate 2.5G bps Transmitter Center Wavelength λ 1528 1564 nm Spectral Width (-20dB) λ 0.3 nm Side Mode Suppression Ratio SMSR 30 db Channel Spacing f 100 GHz Deviation From Central Frequency@EOL -12 12 GHz Average Output Power* (note5) Pout 2 5 dbm Average Launch Power (Tx: OFF) Poff -45 dbm Extinction Ratio* (note6) ER 8.2 db Rise/Fall Time(20%~80%) tr/tf 150 ps Output Optical Eye* (note6) Compatible with IEEE 802.3* (note8) TX_Disable Assert Time t_off 10 us Pout@TX Disable Asserted Pout -45 dbm Relative Intensity Noise RIN -135 db/hz Receiver Center Wavelength λ 1528 1664 nm Receiver Sensitivity* (note7) Pmin -30 dbm Receiver Overload Pmax -9 dbm LOS De-Assert LOSD -31 dbm LOS Assert LOSA -45 dbm LOS Hysteresis* (note9) 0.5 db Note4: Filtered, measured with a PRBS 2 23-1 test pattern @2.5Gbps. Note6: Minimum average optical power at which the BER is less than 1E-12 or lower. Measured with a 2 23-1 NRZ PRBS and ER=9dB. Note7: Measured with a PRBS 2 23-1 tests pattern @2.5Gbps, G.652 SMF, BER 1 10-12. Note8: Eye Pattern Mask Note9: LOS Hysteresis Page 7 of 14

Functional Description of Transceiver SFP Transceiver Electrical Pad Layout Page 8 of 14

Pin Function Definitions Pin Num. Name Function Description 1 VeeT Transmitter Ground 2 TX Fault Transmitter Fault Indication, open collector/drain output 3 TX Disable Transmitter Disable 4 MOD-DEF2 Module Definition 2, Data line for Serial ID. 5 MOD-DEF1 Module Definition 1, Clock line for Serial ID. 6 MOD-DEF0 Module Definition 0, Grounded within the module. 7 Rate Select Not Connect, Function not available 8 LOS Loss of Signal, open collector/drain output 9 VeeR Receiver Ground 10 VeeR Receiver Ground 11 VeeR Receiver Ground 12 RD- Inv. Received Data Out 13 RD+ Received Data Out 14 VeeR Receiver Ground 15 VccR Receiver Power, 3.3 ± 5% 16 VccT Transmitter Power, 3.3 ± 5% 17 VeeT Transmitter Ground 18 TD+ Transmit Data In 19 TD- Inv. Transmit Data In 20 VeeT Transmitter Ground EEPROM The serial interface uses the 2-wire serial CMOS EEPROM protocol defined for the ATMEL AT24C02/04 family of components. When the serial protocol is activated, the host generates the serial clock signal (SCL). The positive edge clocks data into those segments of the EEPROM that are not write protected within the SFP transceiver. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. The Module provides diagnostic information about the present operating conditions. The transceiver generates this diagnostic data by digitization of internal analog signals. Calibration and alarm/warning threshold data is written during device manufacture. Received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring all are implemented. If the module is defined as external calibrated, the diagnostic data are raw A/D values and must be converted to real world units using calibration constants stored in EEPROM locations 56 95 at wire serial bus address A2H. The digital diagnostic memory map specific data field define as following.for detail EEPROM information, please refer to the related document of SFF 8472 Rev 9.3. Page 9 of 14

EEPROM Serial ID Memory Contents Accessing Serial ID Memory uses the 2 wire address 1010000X(A0H). Memory Contents of Serial ID are shown in Table 1. Table 1 Serial ID Memory Contents Addr. Size(bytes) Name of field Vaule(Hex) Description 0 1 Identifier 0B DWDM SFP 1 1 Ext. Identifier XX 2 1 Connector 07 LC connector 00 Reserved 00-00 - 3-10 8 XX Transceiver XX Codes XX 01 Single mode XX 11 1 Encoding XX 12 1 BR, Nominal XX (note10) 13 1 Reserved 00-14 1 Length (9µm)km XX 15 1 Length(9µm)100 m FF Page 10 of 14

16 1 17 1 Length (50µm) 10m Length(62.5µm)1 0m 00 18 1 Length (Copper) 00 Not compliant 19 1 Reserved 00 20~35 16 Vendor Name 36 1 Implemented Optional DWDM Features 00 XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX (note11) 00-37-39 3 Vendor OUI 00 00 00-40-55 16 Vendor PN 56-59 4 Vendor Rev XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX (note11) XX XX XX XX (note11) PN Vendor name 60-62 3 Wavelength XX Laser Wavelength 63 1 CC-BASE XX 64~65 2 Options CC for Base ID fields implemented (addresses 0 to62) 00 Reserved 66 1 BR, max 00-67 1 BR, max 00-68~83 16 Vendor SN XX 1A 1.TX_DISABLE is implemented and disables the serial output; 2.TX_FAULT implemented; signal 3.Loss of Signal implemented Serial number of Transceiver (ASCII) 84~89 6 Date code XX The vendor s date code (ASCII) 90~91 2 92 1 Vendor specific lot code Diagnostic Monitoring Type XX XX - XX 1. Digital diagnostic monitoring implemented 2.Internally/Externally Calibrated; 3.Received power Page 11 of 14

measurement type is Average Power 93 1 1.Optional Alarm/warning flags implemented for all monitored quantities 2. Optional Soft TX_DISABLE Enhanced control and monitoring F0 Options implemented 3. Optional Soft TX_FAULT monitoring Implemented 4. Optional Soft RX_LOS monitoring Implemented 94 1 SFF-8472 Includes functionality described 01 Compliance in Rev 9.3 of SFF-8472. CC for the extended ID Fields 95 1 CC_EXT XX (addresses 64 to 94) implemented. 96~127 32 Vendor Specific XX Read only memory 128-25 5 128 Reserved Read only Note10: The XX byte should be filled in according to practical case. For more information, please refer to the related document of SFP Multi-Source Agreement (MSA). Recommend Circuit Schematic Page 12 of 14

Mechanical Specifications Obtaining Document You can visit our website: http://www.eoptolink.com Or contact Listed at the end of the documentation to get the latest documents. Revision History Revision Initiated Reviewed Approved Revision History Release Date V2.a Tim.Liang Kelly.Cao Released. Oct 24, 2009 V2.b Kelly Revise the A2H. Nov 24, 2009 V2.c Kelly Complete the DWDM wavelength. Jan 18, 2010 V2.d Kelly Correct Rx λ range. Apr 8, 2010 V3.a Kelly Update PN&LOGO. July 19, 2011 V3.b Jans Kelly V3.c Jans Kelly Angela Lyn/Jason/ Walt/Nygai Update EEPROM map, integrate 3 products. Update the Los-Assert of 29dB budget. Update regulatory compliance, Icc, Tr/Toff and the Pout of 17dB and 32dB products. Sep 21, 2011 May 15,2012 Sep 25,2013 Page 13 of 14

Notice: Eoptolink reserves the right to make changes to or discontinue any optical link product or service identified in this publication, without notice, in order to improve design and/or performance. Applications that are described herein for any of the optical link products are for illustrative purposes only. Eoptolink makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Contact: Add: Floor 5, Building 2, No. 21 Gaopeng Avenue, High-Tech District, CHENGDU, SICHUAN 610041 P.R. CHINA Tel: (+86) 028-85122709 ext 816 & 809 Fax: (+86) 028-85121912 Postal: 610041 E-mail:sales@eoptolink.com http://www.eoptolink.com Page 14 of 14