StarWind SMI-S Agent: Storage Provider for SCVMM April 2012

Similar documents
StarWind iscsi SAN & NAS: Configuring HA Storage for Hyper-V October 2012

StarWind iscsi SAN: Configuring HA File Server for SMB NAS February 2012

StarWind iscsi SAN & NAS: Configuring HA File Server on Windows Server 2012 for SMB NAS January 2013

StarWind iscsi SAN Software: Installing StarWind on Windows Server 2008 R2 Server Core

StarWind iscsi SAN: Configuring Global Deduplication May 2012

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability storage with Windows Server 2003 and 2008

StarWind iscsi SAN & NAS: Multipathing October 2012

StarWind iscsi SAN & NAS: Configuring HA Shared Storage for Scale- Out File Servers in Windows Server 2012 January 2013

StarWind iscsi SAN: Global Deduplication with Veeam Backup&Replication

StarWind iscsi SAN Software: Tape Drives Using StarWind and Symantec Backup Exec

StarWind iscsi SAN Configuring HA File Server for SMB NAS

StarWind iscsi SAN Software: Configuring High Availability Storage for VMware vsphere and ESX Server

StarWind iscsi SAN Software: Challenge-Handshake Authentication Protocol (CHAP) for Authentication of Users

StarWind iscsi SAN Software: Using with Citrix XenServer

StarWind iscsi SAN Software: Providing shared storage for Hyper-V's Live Migration feature on two physical servers

StarWind iscsi SAN Software: Using StarWind with MS Cluster on Windows Server 2008

Using SMI-S for Management Automation of StarWind iscsi SAN V8 beta in System Center Virtual Machine Manager 2012 R2

StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with Hyper-V Cluster

StarWind iscsi SAN Software: Using StarWind with VMware ESX Server

VMware/Hyper-V Backup Plug-in User Guide

StarWind iscsi SAN Software: Implementation of Enhanced Data Protection Using StarWind Continuous Data Protection

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster

StarWind iscsi SAN Software: Using StarWind with MS Cluster on Windows Server 2003

StarPort iscsi and ATA-over-Ethernet Initiator: Using Mirror (RAID1) disk device

StarWind Deduplication vs Nexenta Deduplication

StarWind Virtual SAN Hyper-Converged Platform Quick Start Guide

WhatsUp Gold v16.2 Installation and Configuration Guide

Interact for Microsoft Office

EMC ViPR Controller Add-in for Microsoft System Center Virtual Machine Manager

Introduction to Hyper-V High- Availability with Failover Clustering

StarWind RAM Disk: Using as RAM Disk Emulator

Integration Guide. Microsoft Active Directory Rights Management Services (AD RMS) Microsoft Windows Server 2008

Deploying System Center 2012 R2 Configuration Manager

File and Printer Sharing with Microsoft Windows

Sage 200 Web Time & Expenses Guide

Version 5.0. SurfControl Web Filter for Citrix Installation Guide for Service Pack 2

How to Configure a Secure Connection to Microsoft SQL Server

NETWRIX EVENT LOG MANAGER

Active Directory integration with CloudByte ElastiStor

Deploying Personal Virtual Desktops by Using RemoteApp and Desktop Connection Step-by-Step Guide

Using Additional Pollers with WhatsUp Gold v16.0 Learn how to install, configure, and manage pollers for load balancing on your WhatsUp Gold system

Global VPN Client Getting Started Guide

The cloud server setup program installs the cloud server application, Apache Tomcat, Java Runtime Environment, and PostgreSQL.

Tenrox. Single Sign-On (SSO) Setup Guide. January, Tenrox. All rights reserved.

How To Enable A Websphere To Communicate With Ssl On An Ipad From Aaya One X Portal On A Pc Or Macbook Or Ipad (For Acedo) On A Network With A Password Protected (

1. Open the preferences screen by opening the Mail menu and selecting Preferences...

How To Manage Storage With Novell Storage Manager 3.X For Active Directory

Quick Start Guide For Ipswitch Failover v9.0

RoomWizard Synchronization Software Manual Installation Instructions

1. Set Daylight Savings Time Create Migrator Account Assign Migrator Account to Administrator group... 4

NSi Mobile Installation Guide. Version 6.2

CA NetQoS Performance Center

MicrosoftDynam ics GP TenantServices Installation and Adm inistration Guide

DESlock+ Basic Setup Guide ENTERPRISE SERVER ESSENTIAL/STANDARD/PRO

Sophos Endpoint Security and Control standalone startup guide

Introduction to DirectAccess in Windows Server 2012

Troubleshooting File and Printer Sharing in Microsoft Windows XP

Reference and Troubleshooting: FTP, IIS, and Firewall Information

Dell Recovery Manager for Active Directory 8.6. Quick Start Guide

Reconfiguring VMware vsphere Update Manager

Secure IIS Web Server with SSL

For Active Directory Installation Guide

Dell One Identity Cloud Access Manager How to Configure for High Availability

Citrix XenServer Workload Balancing Quick Start. Published February Edition

Server Installation Guide ZENworks Patch Management 6.4 SP2

Installation Guide. Novell Storage Manager for Active Directory. Novell Storage Manager for Active Directory Installation Guide

Setting up Hyper-V for 2X VirtualDesktopServer Manual

Print Audit 6 - SQL Server 2005 Express Edition

CA VPN Client. User Guide for Windows

Deploying Remote Desktop IP Virtualization Step-by-Step Guide

NETWRIX EVENT LOG MANAGER

Technical Brief for Windows Home Server Remote Access

Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide

Getting Started with MozyPro Online Backup Online Software from Time Warner Cable Business Class

Sophos Anti-Virus for NetApp Storage Systems startup guide

Team Foundation Server 2012 Installation Guide

Administration Guide for the System Center Cloud Services Process Pack

CTERA Agent for Mac OS-X

MadCap Software. Upgrading Guide. Pulse

Microsoft System Center 2012 SP1 Virtual Machine Manager with Storwize family products. IBM Systems and Technology Group ISV Enablement January 2014

Connection Broker Managing User Connections to Workstations, Blades, VDI, and More. Quick Start with Microsoft Hyper-V

Server Virtualization with QNAP Turbo NAS and Microsoft Hyper-V

Installing RMFT on an MS Cluster

Installing Policy Patrol on a separate machine

FTP, IIS, and Firewall Reference and Troubleshooting

Building the SAP Business One Cloud Landscape Part of the SAP Business One Cloud Landscape Workshop

Customizing Remote Desktop Web Access by Using Windows SharePoint Services Stepby-Step

Direct Storage Access Using NetApp SnapDrive. Installation & Administration Guide

Nexio Connectus with Nexio G-Scribe

Shavlik Patch for Microsoft System Center

etoken Enterprise For: SSL SSL with etoken

Managing Linux Servers with System Center 2012 R2

Secure Agent Quick Start for Windows

LepideAuditor Suite for File Server. Installation and Configuration Guide

Dell Statistica Statistica Enterprise Installation Instructions

File Auditor for NAS, Net App Edition

HTTP communication between Symantec Enterprise Vault and Clearwell E- Discovery

Microsoft Dynamics GP. Workflow Installation Guide Release 10.0

Mobility Services Platform Software Installation Guide

Wavecrest Certificate

Transcription:

StarWind SMI-S Agent: Storage Provider for SCVMM April 2012

TRADEMARKS StarWind, StarWind Software, and the StarWind and StarWind Software logos are trademarks of StarWind Software that may be registered in some jurisdictions. All other trademarks are owned by their respective owners. CHANGES The material in this document is for informational purposes only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, StarWind Software assumes no liability resulting from errors or omissions in this document, or from the use of the information contained herein. StarWind Software reserves the right to make changes in the product design without reservation and without notifying its users. TECHNICAL SUPPORT AND SERVICES If you have questions about installing or using this software, check this and other documents first - you will find answers to most of your questions here or there. If you need further assistance, please contact us. Copyright 2008-2012 StarWind Software Inc. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written consent of StarWind Software. Page 2

CONTENTS REQUIREMENTS... 4 CONFIGURING THE STARWIND STORAGE SERVER... 5 INSTALLING AND CONFIGURING THE STARWIND SMI-S PROVIDER... 7 CONFIGURING SCVMM 2012... 10 CREATING LOGICAL UNITS THROUGH VMM... 16 CONTACTS... 18 Page 3

REQUIREMENTS This technical paper describes how to enable the StarWind SMI-S Provider for use with the SC Virtual Machine Manager. To complete the installation process successfully, you need to have a customized network infrastructure, configured DNS service, and at least two servers in a domain. One of the servers should have previously installed the SCVMM service, while another one has StarWind iscsi SAN that supports multi-lun targets (v5.8 and later). Page 4

CONFIGURING THE STARWIND STORAGE SERVER Create a new target: 1. Launch the StarWind Management Console by clicking Start -> All Programs -> StarWind Software -> StarWind -> StarWind Management Console. Note: The StarWind Console icon appears in the system tray, when the Console is running. To open StarWind Management Console, double-click or right click its icon. Then, select Start Management Console from the shortcut menu. 2. From the Console tree, select the server you want to provide with the iscsi target device. 3. Double-click the host to connect. 4. You will be prompted to enter your login and password. The default login and password are root and starwind. You can always change them later. Note: Optionally select the Save password checkbox to save a password. 5. To add a target, perform one of the following actions: Select Add Target from the Targets menu. Select Add Target from the host s or target s shortcut menu (right click a host to open it). The Add Target Wizard appears. Please follow the instructions to complete the creation of a new target. 6. Click Next to continue. Page 5

7. Click Next to continue, or click Back to return to the previous steps and change the settings. 8. Click Finish to close the wizard. The successfully added target appears in the StarWind Console. Page 6

INSTALLING AND CONFIGURING STARWIND SMI-S PROVIDER To install StarWind SMI-S Agent: 1. Double-click the installer. 2. When prompted to install the SMI-S Agent as a Windows Service, click Yes. 3. StarWind SMI-S Agent Setup Wizard appears. Click Next to continue. 4. Define the folder to install the SMI-S Agent and click Next. Page 7

5. Click Install to begin the installation process, or click Back to change any settings. 6. During the installation you will be informed about a series of CMD prompts. Click OK to continue the process. 7. To complete the installation process, restart your computer. You can either select Yes, restart the computer now, or do it later by yourself. 8. Click Finish. Page 8

To configure a previously installed SMI-S Agent: 1. Run the ConfiguratorConsole.exe from %INSTALL PATH%\StarWind SMIS\OpenPegasus\bin. Please follow the instructions to ensure proper performance. Note: If SMI-S Agent and StarWind iscsi SAN software were installed on different servers, enter the host IP address and the host name of the StarWind iscsi SAN server. 2. Launch the automated script sslsetup.cmd from %INSTALL PATH%\StarWind SMIS\OpenPegasus\bin to generate an SSL certificate. Please follow the instructions to ensure proper performance. 3. To complete the configuration process, restart your computer. Page 9

CONFIGURING SCVMM 2012 Prior to starting the discovery process, you should setup a Run As Account that is used to connect to the SMI-S Provider. To configure a Run As Account: 1. Launch the VMM Console. 2. Navigate to Settings in the bottom left pane of the VMM Console. 3. At the top of the VMM Console under of the Home tab, expand Create Run As Account. 4. In the Create Run As Account wizard, enter Name (e.g.: Storage Account). 5. Enter a description (optionally). 6. Specify the account with domain administrator permissions in the User name field. 7. Enter password and confirm it. 8. Click OK to save credentials. They will be used when adding a storage device. To discover and classify storage: 1. Launch the VMM Console. 2. Select Fabric in the bottom left pane of the VMM Console. Page 10

3. In the VMM Console, right-click Providers (or Arrays) and select Add Storage Devices. Otherwise, at the top of the VMM Console under the Home tab, expand Add Resources and select Storage Devices. The Add Storage Devices Wizard appears. 4. In the Specify Discovery Scope section of the Add Storage Devices Wizard, enter the IP Address or FQDN and port. Note: If you use SSL connection, select the Use Secure Sockets Layer (SSL) connection checkbox and enter the port 5989. Otherwise, do not select the checkbox and use the port 5988. Page 11

5. Click Browse to start the Run As dialog and select a previously created account or create a new one. 6. Click OK. 7. Click Next to continue. 8. During the discovery process you will be prompted to import the certificate. Click Import to continue. Note: If you receive the error messages "SSL certificate common name is invalid" or "Certificate Authority is not recognized", disable CN verification for the storage provider certificate in the registry. For further details, please refer to the following Microsoft TechNet article: http://technet.microsoft.com/en-us/library/gg610563.aspx Page 12

9. Check the StarWind Storage Array details at the end of discovery process. Click Next to continue. 10. You need to classify the storage pools to make them manageable. Click Create classification. 11. In the New Classification dialog box, enter a name and description and click Add. Page 13

12. Once classifications are created and assigned, ensure that all storage pools are selected and click Next. 13. In the Summary section, confirm the settings and click Finish. Page 14

14. In the SCVMM Fabric workspace, expand Storage and select Providers to ensure that the newly added StarWind Storage Provider is listed with the Responding status. Page 15

CREATING LOGICAL UNITS THROUGH VMM To create logical units: 1. Open the Fabric workspace. 2. Click Storage. 3. Click Create Logical Unit in the Home tab of the Create group. The Create Logical Unit dialog box is opened. 4. Select the needed storage pool from the Storage pool list. 5. Enter a name for the logical unit in the Name box. Note: Use only alphanumeric characters. 6. Enter a description for the logical unit (optionally). 7. Specify the size of the logical unit, in gigabytes in the Size (GB) box. 8. Click OK. To verify the creation of the logical unit: 1. Navigate to Fabric workspace. 2. Expand Storage and click Classifications and Pools. 3. In the Classifications, Storage Pools, and Logical Units pane, expand the storage classification for the pool where the logical unit is created, and select the storage pool. Page 16

4. Check the list of the logical units to ensure that a new logical unit was added. Page 17

CONTACTS Customer Support Portal: Support Forum: Sales: Sales (Germany): General Information: http://www.starwindsoftware.com/support http://www.starwindsoftware.com/forums sales@starwindsoftware.com vschmidberger@starwindsoftware.com info@starwindsoftware.com US Headquarters Tel.: 1-617-449-7717 Fax: 1-617-507-5845 EMEA and APAC Tel.: +44-0-2071936727 +44-0-2071936350 +33-0-977197857 (French) Voicemail: 1-866-790-2646 Germany Monika Str. 13 53757 Sankt Augustin Tel.: +49-1715109103 StarWind Software Inc. 40 Mall Rd., Burlington, MA 01803, USA www.starwindsoftware.com Page 18