Case Study Cross Texas Transmission (CTT) & General Cable



Similar documents
CLEAN LINE ENERGY PARTNERS:

Over land, over sea, overcoming solar, wind power transmission challenges

THE STABILOY BRAND ADVANTAGE UNLOCKING THE SECRETS OF ALUMINUM A LOOK AT THE ADVANTAGES OF ALUMINUM ALLOY OVER COPPER

Financing New High Voltage Transmission Lines in Nepal Using HTLS Conductors Surendra Rajbhandari, Nepal Electricity Authority Zhang Lei, ADB South

Control Number : Item Number : 5. Addendum StartPage : 0

345 kv Brazos Valley Connection Project FAQs

Testimony of Barbara D. Lockwood, P.E. Manager, Renewable Energy Arizona Public Service Company

Hendrix Spacer Cable

The Leader in Wind Energy

environment briefing02

1. Who is CenterPoint Energy Houston Electric, LLC?

Electricity from the Power Plant To the Consumer

Brief Engineering Assessment: Cost estimate for building fiber optics to key anchor institutions

FIXED CHARGE: This is a cost that goes towards making the service available, including

SHE Transmission. 2015_10_30 Transmission Losses Strategy Rev 2.0 October 2015

FINAL. Alternative Evaluation. for the. Proposed Burlington-Wray 230-kilovolt Transmission Project

HERBERT T. HAYDEN SOLAR TECHNOLOGY COORDINATOR FOR ARIZONA PUBLIC SERVICE COMPANY PHOENIX ARIZONA

New York s Transmission Challenges and Opportunities: An Overview

Oncor s Pioneering Transmission Dynamic Line Rating (DLR) Demonstration Lays Foundation for Follow-On Deployments

Using Klein Tools Chicago Grips in Common Overhead Applications

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

STABILOY BRAND FEEDER SOLUTIONS ASSISTED LIVING FACILITIES

CenterPoint Energy Executes Emergency Operating Plan. Hurricane Ike Restoration

From: To: Subject: Date: Attachments:

Eldorado-Ivanpah Transmission Project WELCOME To Southern California Edison Company s Eldorado-Ivanpah Transmission Project OPEN HOUSE

Reconstruction Support after the Great East Japan Earthquake

Wireless Technologies for Wind Turbine Vibration Monitoring

Press Presse Press Presse

S Y S T E M M O D E R N I Z A T I O N

Making The Texas Heat Cool: Geothermal Leasing and Nesting Potential

WHY CABLE TRAY? BECAUSE A CABLE TRAY WIRING SYSTEM PROVIDES SAFE AND DEPENDABLE WAYS TO SAVE NOW AND LATER

Asset Based Carrier or 3PL?

Frequently Asked Transmission Pipeline Questions

SourceGas: Earning Customer Satisfaction Through Call Center Powered by SAP Software

SOUTHERN MARYLAND ELECTRIC COOPERATIVE, INC. HUGHESVILLE, MD

Delivering Clean Energy

Millennium Pipeline Company, LLC Response to New York State Energy Highway RFI

Electric system improvements near you South and West of Edmonton Area Transmission Development

Trees and powerlines. Office of the Technical Regulator. Web: sa.gov.au/energysafe Phone:

BEFORE THE ARKANSAS PUBLIC SERVICE COMMISSION'^^ j E DIRECT TESTIMONY RAJESH GUPTA PROJECT MANAGER, ENTERGY SERVICES, INC.

Program Design and Engineering Key to Infrastructure Replacement and Cost Containment

FREIGHT MANAGEMENT TODAY: HOW TO COMPETE FOR CAPACITY

We Connect. We are proud of what we re doing at AFL. Let us show you how we can make a difference.

Statement for the Record

GE Energy Financial Services

INTERNATIONAL BUSINESS

Decades of experience. 47,000 MW. of operational assets. Top-decile performance. It all means more profitability for you.

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Effect of Temperature on Wireline Cables Technical Bulletin Ten

The MC Cable Revolution is Gaining Ground REMKE

The Advantage of Using IDI

NYSEG and RG&E Emergency Response Power Restoration Practices, Priorities and Interactions

A clean energy solution from cradle to grave

HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

Wind Service Offshore. We can t conquer the elements But we can outthink them

Governor s Two-Storm Panel: Distribution Infrastructure Hardening Options and Recommendations

QUICK FACTS. Providing a Unified Communications Training Solution to End Users Across North America

COMMONWEALTH OF KENTUCKY BEFORE THE KENTUCKY STATE BOARD ON ELECTRIC GENERATION AND TRANSMISSION SITING

Definition of a Lease

AMSC s Superconductor Cable Technologies for Electric Utilities

While there has been a lot of discussion

Who is National Grid?

Understanding the Electric Power Industry s Response and Restoration Process

Pre-Qualification Submittal for Designated Transmission Entity Status

Trees and powerlines. Office of the Technical Regulator. sa.gov.au/energysafe

Developing Ocean Energy in Ireland. Belmullet Wave Energy Test Site

Environmental Health and Safety Management Plan

City of Buffalo Municipal Electric Utility Energy Emergency Response

Renewable Energy Strategy for 2020 and Regulatory Framework. Eng. Hatem Amer Egyptian Electric Regulatory and Consumer Protection Agency

EXHIBIT PH-1. TEXAS CREZ AND LONG TERM NEEDS, A COMPREHENSIVE TRANSMISSION PROPOSAL BY ELECTRIC TRANSMISSION TEXAS, LLC (ETT) February 27, 2007

Morris S. Stover, P.E. Sponsor, Transmission Area

Great Expectations: How Digital Project Planning Fosters Collaboration between Academic Libraries and External Entities

Manufacturing. Detailing. Transmission Structures. Quality. Reliability. Timely Delivery. Design. Prototyping. Testing. Supply. Towers.

Engineered Material Handling. Overhead Bridge Cranes and Gantry Cranes

Your trusted online source for Treasury Management news. Global Finance top pick: U.S. Bank. Working Capital DNA

State of Renewables. US and state-level renewable energy adoption rates:

Spectra Energy Builds a Business

Sort it! Bag it! Tote it! Recycle it!

Highway Motor Transportation

Wired versus wireless trade-offs

FACT SHEET. NEM fast facts:

What Are the Qualifications to Conduct Arc Flash Studies? Where Do You Begin?

SECTOR ASSESSMENT (SUMMARY): ENERGY Sector Performance, Problems, and Opportunities

HVDC Transmission Line Project for Moving ERCOT Wind Into SERC

Conservation of Momentum Greg Kifer

Pipeline Engineering and Field Services

TREE CUTTING & TRIMMING INFORMATION As of

T5 CHARLOTTE REGION WEST DATA CENTER PARK

AU-110 racking guide NBXPN: 023

Linking sustainable ideas to real-world results

ASTROSE. Power line monitoring system for high voltage and extra high voltage power lines. Dr. Volker Großer, Dr. Steffen Kurth, Folie 1.

Summary of Electric Transmission Assessment Report

Hyperlinks are Inactive

Powering Today and Tomorrow. Energy Solutions

COMPANY PROFILE. The main markets serviced by Bahra Cables Company are Saudi Arabia and the countries belonging to the Gulf Cooperating Council (GCC).

AXIS ENTERPRISE RESOURSE PLANNING

Greenlighting Efficiency: 7 Easy Steps to Reduce the Environmental Impact of Today s Supply Chains

Transcription:

Cooperation, Commitment and Communication Successfully Bring Wind Power to Millions in Lone Star State One of the challenges in moving towards renewable energy is that wind farm developers are reluctant to build where transmission lines do not exist and utilities are reluctant to install transmission lines where power generation does not exist. Consequently, renewable energy initiatives require a continued investment in transmission infrastructure coupled with substantial cooperation among experienced industry stakeholders. That s how Great Southwestern Construction Inc. (Great Southwestern), a subsidiary of MYR Group Inc. (MYR Group), successfully constructed 235 miles of transmission lines to move wind-generated electricity from the resource-rich Texas Panhandle to millions across the Lone Star State. 4 Tesseneer drive, Highland Heights, KY 4076 205. General Cable Technologies Corporation. Highland Heights, KY 4076 Telephone: + 859.572.8000

A two-year $27 million portion of a four-year $425 million Cross Texas Transmission (CTT) project, the transmission lines are now commissioned as an esteemed example of modernizing the electrical grid to deliver renewable wind power. Designed to lower total cost of ownership, the sizeable project was completed on time and within budget through strategic partnerships built on cooperation, commitment and communication. Cooperating in the Zone CTT, an affiliate of LS Power, was designated by the Public Utility Commission of Texas (PUCT) to construct, operate and maintain the 235 miles of transmission lines as part of the PUCT s $4.9 billion commitment to deliver renewable energy from Competitive Renewable-Energy Zones (CREZ). These zones, located in West Texas and the Texas Panhandle, are resource-rich, high wind areas. The CREZ projects were ultimately constructed by different utilities to transmit 8,456 megawatts of wind power over more than 2,300 miles of transmission lines from the zones to approximately five million homes and businesses. 4 Tesseneer drive, Highland Heights, KY 4076 205. General Cable Technologies Corporation. Highland Heights, KY 4076 Telephone: + 859.572.8000

The CTT portion of the CREZ initiative consisted of,400 structures that included lattice and monopole steel towers ranging from 00 to 200 feet tall. The 235 miles of transmission lines consisted of doublecircuit 345 kvac lines running in three segments, totaling 2,820 conductor miles. One of the first strategic partnerships for the project originated when CTT selected the Houston Regional Office of Burns & McDonnell as the project engineering firm responsible for the design of the transmission system and associated substations, as well as for providing support for the procurement and bidding process. The primary challenges we faced with a project of this size and scope was selecting the best routes for the transmission lines and engineering around obstacles such as irrigation system and long spans of canyon and river crossings, says Don Cannon, project manager with Burns & McDonnell. 4 Tesseneer drive, Highland Heights, KY 4076 205. General Cable Technologies Corporation. Highland Heights, KY 4076 Telephone: + 859.572.8000

To address higher electrical loads, CTT and other utilities involved in the CREZ initiative selected Aluminum Conductor Steel Supported (ACSS) overhead conductor rather than the Aluminum Conductor Steel Reinforced (ACSR) conductor defined during initial studies. ACSS conductors can operate continuously at higher temperatures than ACSR, which enables increased current carrying capacity (Read more about ACSS at end of case study). While in use for several decades, ACSS has become more common today in re-conductoring to provide a greater cushion for overloading, says Cannon The decision to go with ACSS was a planning-level decision within CTT and other utilities primarily for more ampacity if they ever needed it. Committed to the Challenge CTT selected Great Southwestern to provide material procurement support, right of way (RoW) construction, foundations, conductor installation and final restoration for the project. While the CTT project was the largest in their 36-year history, Great Southwestern s experience, logistical expertise and core values of safety, integrity and teamwork made them the ideal candidate. The overhead conductor selected for the CTT project was General Cable s 590 kcmil Falcon ACSS. Originally patented by Reynolds Metals, now a part of General Cable, the ACSS design is manufactured using the same tried and true process pioneered back in 972. We have a long established relationship with General Cable, and extensive experience with their products on projects of various scopes and magnitudes, says Brandon Lark, President of Great Southwestern. We are extremely familiar with their reputation for delivering quality products and service. The RoW construction and foundations necessitated having five fully-operational construction yards strategically placed along the route to minimize distances. Coordinating the movement of each yard required teamwork of the greatest magnitude. 4 Tesseneer drive, Highland Heights, KY 4076 205. General Cable Technologies Corporation. Highland Heights, KY 4076 Telephone: + 859.572.8000

Typically, most projects require only one or two yards, but the CTT project called for five, explains Mike Bachli, operations manager for Great Southwestern. There is a lot of planning, cooperation and communication involved when moving from one yard to the next. Production cannot stop, and each subsequent yard must to be ready to accept several truckloads of material. Services like electricity, communications and facilities need to be in place prior to these activities taking place. RoW construction for the project required Great Southwestern s flexible communication and coordination skills to ensure access. Crews were met with the challenge of avoiding existing and abandoned gas and oil pipelines traversing throughout the Texas plains. There were times when we had determined alternate access to right of ways, or install culverts to appease land owners, said Bachli. We also had to locate pipelines, which required us to construct special berms and crossings over them so we could safety transport heavy equipment without risk of rupturing the pipelines. 4 Tesseneer drive, Highland Heights, KY 4076 205. General Cable Technologies Corporation. Highland Heights, KY 4076 Telephone: + 859.572.8000

The project was not without environmental challenges everything from heat and wind, to wild hogs, protected wildlife and scorpions, snakes and spiders hiding under pallets and in the plastic coverings on the reels of ACSS. With a strong commitment to safety and teamwork, crews were successful in avoiding the majority of the hazards. We took all the right precautions we kept weeds and grass to a minimum, rocked the yards to discourage critters and kept everything as neat and clean as possible, says Phil Powell, field engineer for Great Southwestern. We did have some wind delays it s not safe to work up on structures when winds are more than 30 miles per hour. We regularly monitored weather forecasts and used wind anemometers to ensure our safety. To help with the CTT project, Sturgeon Electric Company, another subsidiary of MYR Group, mobilized to string nearly 80 miles of the double-circuit 345 kv ACSS lines over a six-month period. Additional crew members were brought from other regions to the project, requiring plenty of cooperation and teamwork. All crews had to comply with Great Southwestern s stringent safety requirements that mandated more than 20 hours of internal safety and OSHA training. 4 Tesseneer drive, Highland Heights, KY 4076 205. General Cable Technologies Corporation. Highland Heights, KY 4076 Telephone: + 859.572.8000

While we had several new employees that required indoctrination into our safety practices, there wasn t anything we failed to complete, says Bachli. Communicating Start to Finish Since its inception in 977, Great Southwestern has successfully completed hundreds of projects, distinguishing themselves in the electrical construction industry. The CTT project was no different. Starting in January 20 amidst the windiest months and installing the last of the lines in August 203, Great Southwestern succeeded in staying on schedule and within budget a challenge that was partly overcome with the help of General Cable s commitment to customer service and support. Great Southwestern has been fortunate to develop a number of successful supplier relationships over the years, and I believe this is due to the fact that we ve been careful about whom we choose to work with, said Lark. One key factor that helped keep the project on schedule was the location of the General Cable manufacturing plant in Malvern, Arkansas just a day s drive from the site and often referred to as a milk run. Having the General Cable plant close by made it easier to change deliveries in the event of weather delays, said Powell. We didn t want to store excess reels of ACSS in the yards, and were able to work closely with General Cable to make sure we had the product we needed where and when we needed it. According to Great Southwestern, working with General Cable was a smooth process from responsiveness and communication, to delivery and billing. Although there was a substantial amount of reels required for the project, General Cable did an outstanding job of making sure we had the right material and quantities on site at all times, Powell said. Their coordination and communication efforts were excellent, and they provided us with detailed shipping reports and accommodated our cut-off billing dates and other requests. 4 Tesseneer drive, Highland Heights, KY 4076 205. General Cable Technologies Corporation. Highland Heights, KY 4076 Telephone: + 859.572.8000

To correlate with Great Southwestern s billing cycle, all material had be on site by the third week of each month. General Cable had to coordinate with production to ensure that the right amount of material was available at that time to keep the project moving forward. Each cable reel was also carefully tracked and labeled based on whichever segment of the transmission lines was being installed. Installations of this magnitude require separate weekly meetings to make sure we stay on track, said Susie Mcallister of General Cable. Great Southwestern was excellent to work with they were very flexible and appreciative of our resources and one-on-one communication. Their understanding of what it takes from a logistical standpoint for us to ensure that the project is successfully completed on time and within budget reflected their years of experience. As a global leader in the wire and cable industry, General Cable has long been committed to sustainable business practices and conservation programs. Dealing with scrap is part of any cabling project, and General Cable s environmental reel return policy and vendor relationships help generate revenue through the recovery of scrap conductor. General Cable collects reels with unusable conductor lengths and processes the scrap to safely recover the metals and pass the savings on to their customers. 4 Tesseneer drive, Highland Heights, KY 4076 205. General Cable Technologies Corporation. Highland Heights, KY 4076 Telephone: + 859.572.8000

For the CTT project, General Cable coordinated with a dedicated carrier for delivery and pick-up of reels, keeping the yards clear and open for new shipments. If less than 000 feet of conductor was remaining on a reel, we couldn t use it, says Powell. Being able to return this scrap conductor back to General Cable was beneficial it eased logistics and we received refunds for the unused portions. We established a special program with General Cable to ensure we could deliver CTT the best return on the scrap conductor. Continuing the Efforts With its proximity to Interstate 40 and Texas state highways, the 235 miles of double-circuit 345 kv lines using General Cable s ACSS conductors and hundreds of structures provides plenty of exposure for everyone involved in the two-year project. The CTT project will certainly help Great Southwestern s momentum in the industry and prepare them for future large-scale projects. For General Cable, the project will provide the leverage to continue bringing ACSS technology and dedicated service commitment to other renewable energy projects around the nation. Already, General Cable s ACSS is being considered for additional wind energy projects throughout the mid-south region. One of the most significant benefits that came from the CTT project included strengthened relationships among all the experienced stakeholders involved. This high profile project is a great addition to our resume for future work, said Cannon of Burns & McDonnell. But the biggest value was that it strengthened our partnership with CTT, Great Southwestern and General Cable, making us well positioned to collaborate on similar future projects. While cooperation, commitment and communication all made for a successful project, the end result is something the industry as a whole can be proud of the delivery of clean renewable wind energy to millions throughout the Lone Star State. 4 Tesseneer drive, Highland Heights, KY 4076 205. General Cable Technologies Corporation. Highland Heights, KY 4076 Telephone: + 859.572.8000

A strong reputation in terms of safety, quality and integrity are imperative for a successful project outcome, and these are values that Great Southwestern strives for on every project, said Lark of Great Southwestern. When we work with suppliers that exhibit the same work behaviors that coincide with our core principles, all project players are aligned and more likely to reach goals and benchmarks in a streamlined, efficient manner. WANT TO LEARN MORE? CLICK HERE TO VIEW THE CTT PROJECT VIDEO! TransPowr ACSS A Better Transmission Choice During times of peak demand, aluminum conductors can reach higher operating temperatures, which can cause thermal expansion, reduced tensile strength and elongation. This introduces susceptibility to high temperature creep (i.e., deformation) problems and conductor sag, reducing the safety clearance of the lines and the potential for connections to become loose, heat up or cause dangerous arcing. Unlike the alternative ACSR conductors that can be susceptible to the long-term creep of aluminum, ACSS conductors are only dependent on the long-term creep of steel wires, which is very low. Even in extreme circumstances, the long-term creep of steel has only a small impact on sag performance. ACSS conductors sag less than ACSR under emergency electrical loading conditions. Additionally, unlike ACSR conductors, ACSS conductor final sags are not affected by the long-term creep of the aluminum. This enables increased current carrying capacity for higher electrical loads. Compared to ACSR with a typical 75 C operating limit, ACSS can operate at up to 250 C. Based on comparison testing under the same environmental conditions, the ampacity rating at 75 C for ACSR is 905 Amps while the ampacity rating at 200 C for ACSS is 660 Amps. Because ACSS conductors offer much higher ampacity, the overall size of the conductor can be smaller. By eliminating the need for larger conductors and shorter reels, pulls can be longer with fewer set-ups. This can help save installation time and labor costs while providing the cushion of a higher ampacity rating. Because the tensile stress in the aluminum wires of the ACSS conductor is much lower than in the alternative ACSR conductors, ACSS is also less susceptible to damage caused by wind-induced Aeolian vibrations something that can cause wires within the ACSR conductor to break. This makes ACSS uniquely positioned to provide better reliability in windy environments like the CREZ areas of Texas. 4 Tesseneer drive, Highland Heights, KY 4076 205. General Cable Technologies Corporation. Highland Heights, KY 4076 Telephone: + 859.572.8000