Fan Applications & System Guide



Similar documents
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

Element D Services Heating, Ventilating, and Air Conditioning

HVAC Calculations and Duct Sizing

Duct Design. Presented by Dave Janquart

Exhaust Calculation Booklet

Below are detailed instructions for using the EMS load calculator.

HVAC Basic Science - System Capacity

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

CHAPTER 4 VENTILATION

Basic Selection & Proper Application of Overhead Air Distribution Devices

VENTILATION CHAPTER 4

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

2006 Delta T Corporation dba Big Ass Fan Company

VENTILATION CHAPTER 4

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

VENTILATION CHAPTER 4

Centrifugal Fans and Pumps are sized to meet the maximum

High Altitude HVAC. Silvertip Integrated Engineering Consultants

VAV Laboratory Room Airflow The Lowdown on Turndown

DUCT DESIGN FOR THE TIME CONSTRAINED WORLD

Makeup Air For Exhaust Systems In Tight Houses. Tony Jellen Engineering Projects

FIRE DAMPER APPLICATION GUIDE

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

Carbon Monoxide Detection in Commercial Buildings (

Integrating Kitchen Exhaust Systems with Building HVAC

Schedule B to By-law Part A Fees Payable for Permits

Building Performance Solutions HVAC Design Guide, 2007

AABC Specifications for Testing and Balancing HVAC Systems

How to Build a Data Centre Cooling Budget. Ian Cathcart

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

HVAC Code Requirements

Characteristics of Evaporators

Energy Savings With Adjustable Frequency Drives. for Centrifugal Fans

Schedule B to By-law

Ventilation Solutions Kitchens. fantech

Energy Efficiency. Energy Efficient Home Cooling:

HVAC Checklist - Long Form

Kitchen Ventilation Systems: Part 2 Providing Adequate Makeup Air

Innovent LASER Packaged Fresh Air Conditioning Units

Low Cost. Lower Energy Costs. Higher Efficiency.

Basics of HVAC Cleaning

Visit us at for more information. Catalog ENG-409 Supersedes ENG-203

Chignecto-Central Regional School Board. Highland Consolidated Middle School. Indoor Air Quality Issues Mechanical Systems

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

Air Side Economizers and Energy Recovery - Improvements and New Regulations. Richard Lord

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

Achieving ENERGY EFFICIENCY with Standard Air-Conditioning Units. Mike West, PhD, PE Advantek Consulting, Inc

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Comparing Energy Savings of Different VAV Systems

ENGINEERING DATA. Fan Performance Troubleshooting Guide

Case Studies: Infrared Heating in Industrial Applications

Demand Based Static Pressure Reset Control for Laboratories

City of Riverside. Building & Safety Division Phone: (951)

Raising the Bar: A Comparison Study of Iowa s Current and Proposed Energy Code

National System of Garage Ventilation s Engineering Guide

CHAPTER 4 VENTILATION

KITCHEN AND BATH REMODELING BUILDING PERMIT REQUIREMENTS

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Washington State University Extension Energy Program

Causes of High Relative Humidity Inside Air Conditioned Buildings. Roger G.Morse AIA, Paul Haas CSP, CIH Morse Zehnter Associates

Commissioning - Construction Documents (Page 1 of 6)

Refrigeration Manual. Part 3 - The Refrigeration Load

AIR DISTRIBUTION FOR COMFORT AND IAQ

HVAC. Kitchen Exhaust. rooftop equipment! let s drop on a few exhaust fans! it doesn t get easier!

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

HVAC FORMULAS. TON OF REFRIGERATION - The amount of heat required to melt a ton (2000 lbs.) of ice at 32 F. 288,000 BTU/24 hr. 12,000 BTU/hr.

Air Conditioning Contractors of America

ENHANCED LABORATORY HVAC SYSTEM

10/9/2012. Poultry Farm Water Supply. Alabama Burglar & Alarm System. Industry Upgrades. Drinkers Fans Water Supply

FAQ' s. Frequently Asked Questions. A1 Control Units. Pge 1 of 7 PUMPKIN HOOK ROAD PO BOX OGD VAN HORNESVILLE NY USA

SECTION MORTUARY REFRIGERATORS

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

SAM HOUSTON STATE UNIVERSITY

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

ACFM vs. SCFM vs. ICFM Series of Technical White Papers from Ohio Medical Corporation

Walkthrough Inspection Checklist

Fans That Sense & Extract Volatile Organic Compounds and Humidity

Greenhouse Cooling. Why is Cooling Needed?

In an effort to improve the city s building permit and inspection processes the building permit fee schedule has been revised and updated.

Displacement Ventilation in Schools

A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses

Element D Services Heating, Ventilating, and Air Conditioning

2014 British Columbia Building Code Changes

Walnut Drying Design and Operation. Selecting Dryer Type. Tray Drying Before Don Osias Jim Thompson

AIR SYSTEM BASICS. form the groundwork for the design, installation, operation, troubleshooting of these systems. Air duct Manometer

HVAC Design Industrial Ventilation

ATTACHMENT A Town of Lakeside Fee Schedule. ANIMALS Annual pet registration fee per animal limit 4 animals $ 8.00 each

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

THE PSYCHROMETRIC CHART AND ITS USE

HVAC Systems in Schools & Commercial Buildings and Radon

University Design Standard. Fire Alarm Systems

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Commercial & Municipal Retrofit 2015 VFD Rebate

MINNESOTA RULES, CHAPTER 1346 MINNESOTA MECHANICAL AND FUEL GAS CODES

Mechanical Systems Proposal revised

CURTAIN TYPE FIRE DAMPERS

HVAC Air Duct Leakage. November 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA

Single Family Residential Basement Finish

Building Permit Application

Transcription:

Fan Applications & System Guide Airflow for general ventilation can be calculated by; Area Method Air Change Method Occupancy Method Ventilation Calculation Methods Area Method Derives the ventilation rate from the area of the space (in square feet) to ventilated multiplied by ventilation rate per square foot. Example: For residential bathrooms up to 100 sq. ft. in area, HVI recommends an exhaust rate of 1 CFM per square foot. A bathroom is 6 x 10 or 60 sq. ft. Multiply 1 cfm x 60 sq. ft. for a flow rate of 60 cfm. Air Change Method - Derives the ventilation rate from the volume of the space (in cubic feet) to be ventilated multiplied by the number of total air changes in one hour. Example: For an auditorium the suggested air change rate is 4 to15 air changes per hour. An auditorium is 80 x 90 with 20 ceiling or 144,000 cu. ft. Use 10 air changes per hour. CFM = 144,000 cu. ft. x 10 AC p/ hr CFM = 24,000 60 Occupancy Method - Derives the ventilation rate from the number of people that will occupy the space at any given time. Example: For an office, the recommended ventilation rate is 20 cfm per person. The occupancy of a general office is one person per 80 to 150 sq. ft. An office is 40 x 60 or 2,400 sq. ft. Occupancy = 2,400 sq. ft./150 sq, ft p/ person CFM = 16 people x 20 cfm per person CFM = 320 Heat Removal Method When the temperature of a space is higher than the ambient outdoor temperature general ventilation can be used to provide cooling. What is needed to calculate CFM is the amount of heat to be removed in BTU/hr, the desired indoor temperature and design outdoor dry bulb temperature. Example: 200,000 BTU/hr to be removed, 70 degree desired indoor temperature and 90 outdoor dry bulb temperature. CFM = 200,000 (BTU/hr) / (1.08 x 90-70) CFM = 9,260 (Note: rule of thumb outdoor / indoor temperature differential is 20 degrees)

Applications Listed below are ventilation rates for some common applications. Where more than one method is shown use the method that results in the higher airflow rate. Application Area Air Change Occupancy Method Other Method Method cfm/ person sq ft/ person General Ventilation 1 cfm Attic Ventilation.7 cfm 10 Auditoriums 4 to 15 Banks 4 to 10 20 50 to 150 Battery Charge Room 1.5 cfm 4 Boiler Room 15 to 30 Chemical Storgage Area 1.5 cfm Class Room 15 0.05 Computer Room 15 to 20 20 80 to 150 Conference Room 20 0.05 Corridors.05 cfm Churches 20 5 to 20 Elevators 1 cfm Electrical Room 2 cfm 10 5 cfm / KVA of transf. Fire Station 4 to 10 20 100 to 500 Garage (Parking) 1.5 cfm 5 to 15 Garage (Repair) 6 to 30 5000 cfm / car Gymnasium 6 to 30 Hospital (Patient Rooms) 25 0.01 Kitchen Hood (Charbroiler) 300 cfm x linear. ft.. Kitchen Hood (Island Type) 150 cfm / sq. ft. Kitchen Hood (Wall Mounted) 100 cfm / sq. ft. Kitchen (General Ventilation) 1.5 12 to 15 15 50 to 150 Libraries / Museums 20 30 to 100 Locker Room 12 to 30 Manufacturing (Light) 5 to 10 Manufacturing (Heavy) 10 to 20 Mechanical Room 2 cfm Mech. Room (Combustion Air) 8 cfm / BHP Mech. Room (Comb. Exhaust) 2 cfm / BHP Medical / Dental Office 8 to 12 20 50 to 150 Municipal Buildings 4 to 10 20 50 to 150 Police Station 4 to 10 20 100 to 500 Retail Store.3 cfm 15 15 to 75 Supermarket 15 50 to 100 Toilet Room (Public) 75 cfm p/ WC & urinal Toilet Room (Residential) 1 cfm 8 Warehouse Ventilation 1 cfm 6 to 15 Welding Operation 2500 cfm p/ welder

Systems General Ventilation Plan and Spec Jobs - required airflow and system static pressure is calculated by the engineer and is listed on the fan schedule. Retro Fit and Design Build Jobs - the system static pressure can be calculated using the required airflow, the duct size, duct layout and total duct length and duct friction loss chart (Friction Loss Chart needed). When the duct layout is not known the following rules of thumb can be used to estimate system static pressure 1. Non Ducted Applications -.10 to.25 2. Ducted Applications -.20 to.40 per 100 feet of duct (based on duct velocity of 1000 to 1800 feet per minute). Fittings.08 per fitting (elbows, register, grille, damper) Example: Retrofit a fan for a mechanical room. Area of room is 20 x 60 or 1,200 sq, ft. Fan is ducted to roof with 16 x 16 duct. Total duct run is 25. There are 2 elbows and a grille in the system. Required Air Flow - 2,400 cfm. (2 cfm p/ sq. ft. x 1200 sq. ft.) Duct Velocity 1,400 fpm (air flow / duct area) Duct Losses -.08 (.30 / 100 ft of duct x 25 ) Fitting Losss -.24 (.08 x 3 fittings) Estimated SP. =.08 +.24, round to nearest 1/8. Size Fan for 2,400 cfm @.375 sp Another rule of thumb that can be used if number of fittings is not known is; Estimated SP. = 1.5 x System Length (ft.) x Friction Rate (Inches W.G.)* *Friction Loss Chart needed 100 100 Kitchen Hoods Use.625 to 1.50 sp. Minimum duct velocity 1,500 fpm Make up air 80% of exhaust air Sound Level Guidelines Application Sones Bathroom 13 to 18 Conference Room 1.7 to 5 Corridors 9 to 13 Church 1.5 to 5 Hospital Private Room 1.7 to 5 Hospital Ward 2.5 to 9 Kitchens 10 to 18 Application Sones Manufacturing (Light) 12 to 36 Manufacturing (Heavy) 20 to 50 Office (Open) 4 to 12 Office (Professional) 3 to 9 Post Office 4 to 12 Schools & Classrooms 2.5 to 8

Basic Fan Laws Fan Laws are equations used to predict a fan s performance at other conditions. Once a system is installed if the CFM, SP and BHP are known (by measurement) the CFM, SP and BHP at every other point along the system curve can be calculated. VARIATION FAN SPEED CHANGE DENSITY CHANGE VOLUME PRESSURE With Speed Ratio cfm2 = cfm1 (rpm2 / rpm1) Varies with SQUARE of Speed Ratio No Change with density Ratio P2 = P1 (rpm2 / rpm1) 2 P2 = P1 (D2 / D1) HORSE Varies wwith CUBE of Speed Ratio with density Ratio POWER hp2 = hp1 (rpm2 / rpm1) 3 hp2 = hp1 (D2 / D1) Example: Fan is selected at 4,000 CFM @.50 SP, 825 RPM and.72 BHP. Balancer reports 3,000 CFM @.375 SP, 825 rpm and motor operating at nameplate full load amps. Calculate the required RPM using fan laws CFM2 / CFM1 = RPM2 / RPM1 4,000 / 3,000 = RPM2 / 825, New RPM = 1100 Calculate the new SP using fan laws SP2 / SP1 = (RPM2 / RPM1)2 SP2 /.375 = (1100 / 825)2, New SP =.67 Calculate the new BHP using fan laws BHP2 / BHP1 = (RPM2 / RPM1)3 BHP2 =.75 because fan motor was operating nameplate amps BHP2 /.75 = (1100 / 825)3, New BHP = 1.78 The system SP is actually higher than calculated. To meet the operation point at the new SP the fan will need to operate at 1,100 rpm and will require a 2 hp motor.

Air Density Correction Fan performance tables are based on standard air conditions. An installation s altitude and the air temperature will affect the air density. Use the Air Density Correction Factors (df) listed below to determine the corrected fan performance. Correction for temperatures between 40 deg. F and 100 deg. F and/or elevations between 1,000 ft. and +1,000 ft. are generally not required. Air Density Correction Factors (df) Altitude TEMPERATURE (Degrees F) (Ft) 70 100 200 300 400 500 600 700 800 0 1.00 0.95 0.80 0.70 0.62 0.55 0.50 0.46 0.42 1000 0.96 0.91 0.77 0.67 0.59 0.53 0.48 0.44 0.41 2000 0.93 0.88 0.75 0.65 0.57 0.51 0.46 0.42 0.39 3000 0.90 0.85 0.72 0.62 0.55 0.49 0.45 0.41 0.38 4000 0.86 0.82 0.69 0.60 0.53 0.48 0.43 0.39 0.36 5000 0.83 0.79 0.67 0.58 0.51 0.46 0.42 0.38 0.35 6000 0.80 0.76 0.64 0.56 0.49 0.44 0.40 0.37 0.34 7000 0.77 0.73 0.62 0.54 0.48 0.43 0.39 0.35 0.32 8000 0.74 0.70 0.60 0.52 0.46 0.41 0.37 0.34 0.31 9000 0.71 0.68 0.57 0.50 0.44 0.39 0.36 0.33 0.30 10000 0.69 0.65 0.55 0.48 0.42 0.38 0.34 0.31 0.29 Example: A fan is selected to deliver 4,000 CFM @.25 SP. Fan will be installed 5,000 ft above sea level; air temperature is 70 deg. F. From the Air Density Correction Factor table above the density correction factor (df) is determined to be.86 by using the fans operating altitude. Divide design SP by the Air Density Correction Factors (df).25 sp /.86 =.29 sp It is determined by from the fan performance table that the fan must operate at 774 rpm to develop the design CFM at the corrected SP at 5,000 feet above sea level at the operating temperature of 70 deg. F. From the fan s performance table it is determined that at standard conditions.51 BHP is needed meet the design point. This is corrected to conditions at altitude by multiplying the BHP by the Air Density Correction Factor.51 BHP x.86 =.44 BHP The final operating conditions at altitude are determined to be 4,000 CFM @.25 SP, 774 rpm and.44 BHP