Globo P. Ball valves Pump ball valve made of gunmetal

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Valve range. To be precise.

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

RADIATOR VALVE. type m72. Page 1

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Assisted lift operated 2/2-way solenoid valves Type EV250B

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

V1810. Alwa-Kombi-4 Circulation throttle valve. Product data

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

ASSEMBLY INSTRUCTIONS ACCORDING TO SAE J1453 FOR FLARED TUBES. 5. Clean properly with appropriate products the part of the tube to be flared.

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Overview of types. Technical data

Thermostatic valve Type AVTA

stainless steel pre-assembled manifolds

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

Self-operated Temperature Regulators Temperature Regulator Type 1u

Data sheet ECC 12 and 22

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Cooling system components, removing and installing

Hose and Tube Fittings Series 1-3

CERT. TO ASSE STD 1016 AND AND AND 1017 WT. LBS.

Installation and Operation Instructions Domestic hot water modules: FriwaMidi DN 20 FriwaMaxi DN 25

Installation Instructions S

EWE Ball Valve-Type Tapping Valve. EWE Ball-Type Tapping Valve. EWE GBM Tapping Valves. for water and gas

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

Hose Clamps & Fittings

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Refrigeration and air conditioning Date: 10/2013

Thermostatic element RAVV for 2-way valves

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

HERZ-Thermal Actuators

STABITHERM INSTALLATION & SERVICE BOOKLET

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Solenoid valves 2/2-way direct-operated Type EV210A

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Operating Instructions for Plastic Flow Meter. Model: KSK

V5001S. Kombi-S Shutoff Valve. Product specification sheet

Radiator valve accessories

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

ECOSTYLE RADIANT PANELS Installa on and Opera on Manual 2013

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Type overview. Technical data

Watts Pure Water Systems

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

M A N U A L

Technical catalogue convectors POLAND 2012

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

PLUMBING CARE AND REPAIR

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

FAG Hydraulic nuts. Technical Product Information

Lubricant distributors

Wiper Motor Marinco 2.5. Installation Instructions

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

Operators manual Basic water heater

Cylinder head, removing and replacing

Water Pump Replacement

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Zenith Solar thermal 4.5m pump station Installation manual

Overflow valve with thread connection

NFPA31FuelOilPiping 1 Revised

Self-operated Temperature Regulators Type 1 to Type 9. PN 16 to 40 Class 125 to 300 DN 15 to 250 NPS ½ to 10 G ½ to 1 Up to 350 C Up to 660 F

Constantemp Double Wall Low pressure steam-water Heater F-340LDW,F-640LDW, F-940LDW and F-1240LDW

building applications copper - redefined

Ve-Lock manufactures Needle Valves from Solid bar stock Materials & all parts details are as below:

SERVICE SERVICE COMPACT MANUAL. Mod X Mod X Mod X. Part 2

Installation Instructions

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

Duplex Filters 40/160 LD /160 LDN Industrial Filters Accumulators. Filters for inline installation for continuous operation

Thermostatic Actuators

This instruction is valid for all ACD pump models shown on page 2

GATE VALVES ASAHI AV VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

Machine needle shut-off nozzle type HP

Trouble shooting guide

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Ocean Engineering Technical Data Sheet Stuffing Tubes

Automatic Bypass Control AVDO

6 inch A-Arm Lift Kit WARNING: / installation instructions. will fit CLUB CAR DS. included:

Select Radiators Installation Guide

Solar Collector Series. Product List

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

Easy Tool Retracting System CMC-SR2159ER36

Installation Instructions

Operating Instructions

Automatic control equipment for HVAC systems

Eliminator Vented Disc Brake Owners Manual

Pneumatic actuators The Original! Technics of the top class.

Economy Combo Heat Press Manual Model No.: ECH-800

Pressure switches and thermostats, type KPS

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Transcription:

Manual radiator valves To be precise.

Description HEIMEIER Mikrotherm manual radiator valves made of corrosion-resistant gunmetal, with white plastic hand wheel cap, tight-packed with protection film. Lengths according to DIN 84 part. Accurate presetting of the mass flow and finest heat apportioning through a non-rising double spindle with a Mikrotherm presetting cone with tandem sealing (metal and O-ring sealing). Spindle for NW to NW with double O-ring sealing. Spindle sealing for NW and NW through stuffing box packaging which can be tightened. Can be retrofitted as a thermostatic valve by replacing the Mikrotherm insert with a thermostatic insert. Can be connected to a threaded pipe, or with compression fittings to a copper, precision steel or multi-layerpipe. For HEIMEIER Mikrotherm, only use the auxiliary, labelled HEIMEIER compression fittings (label e. g. THE). Assembly Mikrotherm Double O-ring sealing Double spindle Tandem sealing Presetting cone Body made of corrosion-resistant gunmetal nickel plated Double O-ring sealing (NW NW ) Presetting through a non-rising double spindle Can be retrofitted as a thermostatic valve

Application The HEIMEIER Mikrotherm manual radiator valve is used in warm water pump heating systems, gravity or low pressure steam systems. With models in angle and straight form from NW to NW, Sample application the manual radiator valve can be used for a number of different purposes. The non-rising double spindle with the Mikrotherm presetting cone makes hydraulic balancing through presetting Mikrotherm possible. The aim here is to provide e. g. all heat consumers with hot water according to their needs. Note The contents of the heat transfer medium should comply with VDI guideline on damage and scale deposit formation in warm water heating systems. For industrial and long-distance energy systems, see the applicable codes VdTÜV 466 and AGFW /. Mineral oils in the heat transfer medium or lubricants containing mineral oils of any type lead to strong swelling and in most cases cause EP seals to fail. When using nitrite-free frost and corrosion resistance solutions with an ethylene glycol base, pay close attention to the details outlined in the manufacturers documentation, particularly details concerning concentration and specific additives. Operation Article numbers Presetting. Close the valve.. Unscrew the hand wheel fastening screw.. Screw in the control pin with a screw driver by turning it clockwise until it stops. 4. Use the diagrams to determine the presetting and preset by turning to the left.. Insert the hand wheel fastening screw and screw tight. Notes: The insert should only be loosened or tightened when the valve is opened. After the first test heating with NW and NW, check the stuffing box union nut and tighten if necessary. Structure NW k vs value Gunmetal nickel-pl.. [m/h] Art. no. Angle Straight (/ 8 ).7 0 0.0 (/ ).99 0 0.0 (/ 4 ). 0 0.0 ( ) 6. 0 04.0 (/ 4 ). 0 0.0 (/ 8 ).7 0 0.0 (/ ).6 0 0.0 (/ 4 ). 0 0.0 ( ) 6. 0 04.0 (/ 4 ) 8.90 0 0.0 Permitted operating temperature TB C (48 F). Permitted operating pressure PB bar, low pressure steam C ( F)/ 0. bar.

Accessories Illustration Description L [mm] NW Ø pipe Art. no. L Compression fitting For copper or precision steel pipe female thread connection Rp / 8 Rp / 4. For a pipe thickness of 0.8 mm, support sleeves should be used. Note the information provided by the manufacturer. Support sleeve For copper or precision steel pipes with a wall thickness of mm. Compression fitting For multi-layer pipes. Female thread connection Rp /. Conversion insert for valve bodies with a T label. Series to 98. Valve Nickel-plated brass (/ 8 ) -. (/ ) -. (/ 8 ) -. (/ ) -. (/ ) 4-4. (/ ) -. (/ ) 6-6. (/ 4 ) 8-8. (/ 4 ) -. 8, 0-.70,0 0-.70,0 4 0-4.70 6,0 0-.70 6, 6 0-6.70 6,8 8 0-8.70 Nickel-plated brass 4 x -4. 6 x -6. (/ 8 ), 4-0.0 (/ ) (/ 4 ) 4-0.0 ( ) 0-04.99 (/ 4 ) 0-0.99 Conversion insert for valve bodies with a connector thread for the thermostatic head. Series from 98. (/ 8 ), -0.0 (/ ) (/ 4 ) 0-0.0 Standard. Conversion insert for valve bodies with a boss marking. Series from 994. (/ 8 ), 0-0.0 (/ ) Numerical cap Numerical cap Presetting (V-exakt). Conversion insert for valve bodies with a boss marking. Brass numerical cap. Series from 994. Finest presetting (F-exakt). Conversion insert for valve bodies with a boss marking. Nickel-plated brass numerical cap. Series from 994. (/ 8 ), -0.0 (/ ) (/ 8 ), 4-0.0 (/ ) mm = 0,094 inch 4

Technical data Diagram NW (/ 8 ) (angle) (straight) 0-0 / 0-0 /æ-value Œ 0,06 0, æ,7,4 0,8 0, 0,6 0,4 æ,7 0 00 0 00 4 6 7 8 9 9 0 0 00 00 0 0 0 0 0, 0, 0, 0, 0 0 0 0 00 00 Druckverlust Δp [mm WS] Diagram NW (/ ) (angle) (straight) 0-0 / 0-0 /æ-value Œ 0,06 0,, 0, 0,4 0,74 0,4 æ,6,7 æ,99 0 00 0 00 4 6 7 8 9 9 0 0 00 00 0 0 0 0, 0, 0, 0, 0 0 0 0 00 00 0 Pressure loss Δp [mm WS]

Technical data Diagram NW (/ 4 ) (angle) (staight) 0-0 / 0-0 /æ-value Œ 0,064 0, 0, 0,, 0,4,,98 0 æ, æ, 00 0 00 4 6 7 8 9 0 0 00 00 0 0 0 0, 0, 0, 0, 0 0 0 0 00 00 0 Pressure loss Δp [mm WS] Diagram NW ( ) (angle) (straight) 0-04 / 0-04 /æ-value Œ 0,46 0,77,7,,4,8, 4,4 æ 6, æ 6,6 0 00 0 00 0 00 4 6 7 8 9 0 00 0 0 0 0, 0, 0, 0, 0 0 0 0 00 00 00 00 0 Pressure loss Δp [mm WS] 6

Technical data Diagram NW (/ 4 ) (angle) (straight) 0-0 / 0-0 /æ-value Œ 0,7 0,79 7,9 6,6,,4,,8 0 æ 8,9 æ, 00 0 00 4 6 7 8 0 0 00 00 0 0 0 0, 0, 0, 0, 0 0 0 0 00 00 00 00 0 Pressure loss Δp [mm WS] Sample calculation Target: Preset value Given: Heat flow º = W Temperature spread Δt = K (70/ C) Pressure loss in manual valve NW Δp v = mbar Solution: Mass flow ª = º = = 9 kg/h c. Δt.6. Screw driver turns form diagram NW, page = 6. turns Formula: C v = k v 0,86 k v =C v 0,86 7

Dimensional data sheet Lengths according to DIN 84, part Angle form Straight form Ø D Ø D H SW H SW SW l d d D d d α α b SW D l 6 l l 4 b l l l 6 NW D b d d I I I I 4 I I 6 α Spanner opening H D.. min. SW SW R p / 8. G / 8 R / 8 9 8 6 6 7 6 4 R p /. G / 4 R / 66 9 9 8 6 7 7 6 4 R p / 4 4. G R / 4 74 6 4 66 9 8 70 7 8 4 R p G / 4 R 84 8 40 7. 9 4 47 7 R p / 4 G / R / 4 9 46 8 9 49 74 mm = 0,094 inch Brochure 4. Printed on chlorine-free bleached paper. 40-8.48 / 04.07 We reserve the right to make technical changes. Theodor Heimeier Metallwerk GmbH Postfach 4, 99 Erwitte, Germany Phone +49 94 89-0 Fax +49 94 89-0 www.heimeier.com