1. Introduction. 2. Components. 3. Optical Specifications. 4. Electric Specifications. 5. Dimension. 6. Operating Environment. 7.



Similar documents
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Thyristor-controlled power supplies and battery chargers

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

User s Manual Before using the inverter, you need to read and save the safety instructions.

Failure code manual. content

High Power Programmable DC Power Supplies PVS Series

TIG INVERTER INSTRUCTION MANUAL

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

HERZ-Thermal Actuators

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Research RF Sputtering Packages

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

TORKEL 820 Battery Load Unit

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Model: DC-A2IO Advanced HVAC Controller

Electric Rotary Actuator - On/Off or programmable control actuator

CONFIGURABLE SAFETY RELAYS

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

CAUTION OPC-LM1-IL. Option Card for Encoder of Line Driver Output. Instruction Manual

Diesel Generating Set

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Multi-Range Programmable DC Power Supplies 9115 Series

USER S MANUAL HSC-24A

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

How To Make A Fronius Cl Power Inverter

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

I STAR COMPUTER CO., LTD

Agilent 4338B Milliohm Meter

14. Troubleshooting Guide

PE8216/PE8324. Energy Intelligence Solutions

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

BB800 Off-Grid Solar System

Unico Inverter. Unique and efficient.

Photovoltaic Solar Energy Unit EESFB

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

EFC Frequency converters

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

SOLAR I-V Rel /07/10

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

650W Single Output Power Supply

DCS Series 1 kw, 1.2 kw, & 3 kw

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

CQM1-SF200/CS1W-SF200

PowerGem Pro Uninterruptible Power Supply

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

DCS Input/Output Relay Card Series

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

1.44 kw Programmable DC Power Supplies XLN Series

DC Electronic Loads 8500 series

HIGH PRODUCTION DUAL DRIVE HORIZONTAL MACHINING CENTER

World Leader in HV Testing Technology

Multi-Range Programmable DC Power Supplies 9115 Series

KLQ750CO controller temp/intensity/feedback/24v/usb/rs622/analog trigger

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space

Current Monitoring Kit QUICK START GUIDE

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

F2400 FOM II Series Fiber Optic Modem Technical Manual

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

for Energy Storage System, New & Renewable Energy

Incubator with mechanical convection

User s Manual. Wind/Solar Hybrid Controller NV-SW10C48. Please Read This User Manual Carefully Prior to Installation and. Operation of This Product.

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

Solar energy Solar technology in endurance testing

HYDRUS ULTRASONIC METER

The solution for Europe: Type 2 charging socket with or without shutter

Guideline Laser Series

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

CC-Link Ver.1.10 Compatible

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Meaco 30L and Meaco 40L dehumidifier instruction manual

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

ITEM MODEL QTY. Filter ITEM MODEL QTY USB-RS485 Converter (with 3716A-21) 3716A-20 1

Microwave Meter. Instruction Manual

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Input module, input/output module

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Electronic Control Devices The European Product Catalogue 2007

DUST EMISSION MONITORING SYSTEM

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

IXOLAR TM High Efficiency SolarMD.

How To Control A Battery Cell Phone With A Battery Power Control System

Transcription:

SPECIFICATIONS Super Model: XHS-220S1 Class Solar Simulator 1. Introduction 2. Components 3. Optical Specifications 4. Electric Specifications 5. Dimension 6. Operating Environment 7. Warranty SAN-EI ELECTRIC CO., LTD 533-0006 3-19-50, KAMISHINJO, HIGASHIYODOGAWA-KU, OSAKA, JAPAN TEL 06-6379-0010 FAX 06-6379-0070 April-2013

1. Introduction This super AAA class solar simulator is designed for 8inch cell (effective irradiated area 220mm). By an innovative optical design, this Solar Simulator presents a mixing light from Halogen Lamp and Xenon Lamp, which can mostly fit the real sunlight. And the spectral mismatch within ±5% (JIS C 8942 MS class) is possible. By using the finest optical components and feedback control technology all of optical specifications certified much better than class AAA (JIS C 8912 / IEC 60904-9 (2007) / ASTM E927-5). System Configuration Model Light Source Unit Size Weight Power Supply Size (with rack) Weight (with rack) XHS-220S1 XHS-2350T1 W520 H1069 D1045 mm 90kg XHC-2350M1 W544 H900 D660 mm 52kg Filter AM 1.5G Lamp Accessories 1.6kw Xenon Lamp & 750w Halogen Lamp Power Input Cable (3.5sq, triplex, with earth terminal) Halogen Power Input Cable (triplex) Xenon Power Cable (duplex) Halogen Power Cable (duplex) Shutter Cable (triplex) Inter-lock/Fan Motor Cable (14 core) Feedback Signal Cable (7 core) Remote Control Cable A (30 core flat cable) Operation Manual - 2 -

2. Components Shutter Unit Output Adjustment Lamp Output Display Cooling Fan Motor Interlock Overheat Prevention Mechanism Lamp Hour Meter Optical Axis Adjustment Mechanism Feedback Control External Control Monitoring Functions Manual or timer controlled (0.1 S ~ 9990 Hrs) By changing the current lamp power(60~100%) Indicating Xenon Lamp Power, Current, Voltage Indicating Halogen Lamp Current, Voltage Auto-stop after the lamp extinguished over 20 minutes Lamp shutoff automatically when the lamp exchange door is open 80 C thermostat inside light source unit. 80 C thermostat inside power supply unit. Indicating operation time of lamp (with lifetime alarm) X-axis, Y-axis, Z-axis adjustment knob, Arc Monitor Constantly control irradiance of solar simulator with a feedback system, which inside power supply. *Power input signals *Lamp on/off input and output signals *Manual shutter opening input signals *Shutter timer start input signals *Shutter open confirmation output signals *Shutter closed confirmation output signals *Lamp on confirmation output signals *Lamp stability indicator output signals *Light source over-heat alarm output signals *Power supply over-heat alarm output signals (Xenon/Halogen) *Inter-lock alarm output signals *Lamp life time over alarm output signals - 3 -

3. Optical Specifications Effective Irradiated Area AM filter Irradiance Irradiation Distance Temporal Instability of Irradiance Irradiance Uniformity Spectral Mismatch Lamp Life Time 220mm AM1.5G 1,000W/m2 (1 SUN) 470mm <±1% (JIS C 8912/IEC/ASTM Class A, JIS C 8942: 2009 Class MS) <±2% (JIS C 8912/IEC/ASTM Class A, JIS C 8942: 2009 Class MS) AM 1.5G <±5% (JIS C 8912/IEC/ASTM Class A) (JIS C 8942: 2009 Class MS) Xenon lamp: average 1,000h Halogen lamp: average 300h JIS C 8942 (Solar simulator for multi-junction solar cells and modules) Item Classification MS MA B C Non-uniformity Less than Less than Less than Less than of Irradiance ±2% ±2% ±3% ±10% Temporal Instability Less than Less than Less than Less than of Irradiance ±1% ±1% ±3% ±10% Spectral Mismatch 0.95-1.05 0.75 1.25 0.60 1.40 0.40 2.00 4. Electric Specifications Rated Input Rated Lamp Voltage Insulation Resistance Voltage Endurance AC200-240V (±10%) 50/60Hz 1φ 3.6kVA (MAX) Xenon lamp: 1600W Halogen lamp: 750W DC 500V above 20MΩ Input~Output / Output between F.G~between F.G Output~between F.G Input ~ Output between F.G AC 1,000 V 1 minute Output ~ between FG AC 500 V 1 minute - 4 -

5. Dimension A. Light Source Unit: XES-2350T1-5 -

B. Power Supply Unit: XEC-2350M1+ Rack - 6 -

6. Operating Environment Temperature 5~35 (RT value, temperature change within 5 ) Humidity 20 ~85% (RH value, No Condensation) 7. Warranty Warranty period covers one year after delivery with a service time (accumulated lamp lighting time) less than 1,000 hours. Should incident or malfunctioning occur due to design or manufacturing defects of our company within the above mentioned warranty period, compensation is provided for repair or replacement of the malfunctioning parts only. Please clearly indicate the details of the claimed malfunctions and ship the device to our company. The warranty does not cover the following items: 1) Accidents or malfunctions occur as a result of wrongful usages not covered in this manual. 2) Malfunction or accidents resulted from modification unauthorized by SAN-EI electric Co., Ltd. 3) Malfunction or secondary damages from natural or man-made calamities. 4) Damage compensations for accidents or malfunction. 5) Damage compensations for patent infringement by users operating this device. - 7 -