INSTALLATION INSTRUCTION



Similar documents
Installation Instructions for Fletco Carpets

If you hire a Professional Wood Fitter. If fitting the Wood Floor yourself (DIY)

Euro Oak Installation

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

ENGLISH Installation guidelines for 10mm Engineered LOC flooring

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

Your guide to home maintenance. Flat Roofs

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

Carpet Tile Installation Guidelines

LIFE SCIENCE. Hoop House Construction for New Mexico: 12-ft. x 40-ft. Hoop House BRINGING TO YOUR HOME ECONOMICS COLLEGE OF AGRICULTURE AND

The Mohawk Group Installation Guidelines for

WATERPROOFING OF WET ROOMS

Installation for Wood Flooring

Care and Maintenance for Wood Flooring

NEW BATHROOMS. ONYX, AQUALON & FORZA Floors and walls for wet rooms SAFE, ATTRACTIVE & INEXPENSIVE! creating better environments

peel adhesion 2 breaking load 4 rolling ball 6 shear adhesion 7 carton test 9 summary test methods 11

ENERGY SAVING WINDOW FILMS S LAR CONTROL

Selecting a Carpet and Pad

CARPET WARRANTY GUIDE

Redefined style for intimate living. high quality woven carpets

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

INSTALLATION INSTRUCTIONS FOR LAMINATE FLOORING

DENSO WATERPROOFING SYSTEMS

INDUTAINER COLLAPSIBLE IBCs FOR LIQUIDS

DELTA Premium Moisture Management Systems for Foundations.

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

FLOOR MAINTENANCE GUIDE EXPECTATIONS AVOIDING PROBLEMS

BELMONDO rubber floorings for horses

Division 9. SignaFlor Pad and Pour Flooring System

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

Columbia flooring will resist fading from exposure to sunlight or artificial light.

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

Australian Edition. Redbook Carpets with total technology are proudly supplied by: Feltex Carpets Pty Ltd ABN:

Guide Specification SECTION SHEET CARPETING PART 1 - GENERAL 1.1 SUMMARY. A. This Section includes broadloom carpet. 1.

Grand Mesa Plus LAMINATE - WIRE BRUSHED. GAGVGM81012A Prairie. GAGVGM80012NA Colorado. GAGVGM84012A Pecan Rustic. GAGVGM85012A Saddle Walnut

YOUR ESSENTIAL GUIDE TO NATURAL FLOORCOVERINGS VOL2

M50 RUBBER/PLASTICS/CORK/LINO/CARPET TILING/ SHEETING

How to Install Hardwood Flooring Over a Sub Floor


Herringbone Pattern Flooring

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

DESSO CARPET TILES / BROADLOOM CLEANING AND MAINTENANCE

Laminate Flooring T-Lock Angle-Drop Installation Instructions

Wecryl Waterproofing System under surfacing supplied by others

Selecting Vinyl Flooring

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

HARDWOOD WARRANTIES Limited Warranty for Prefinished Solid, Engineered, and Longstrip Floors Manufacturing Defects Finish Warranty

GENERAL PROVISIONS

WATER AND WOOD DON T MIX KEEPING YOUR TRIÂNGULO HARDWOOD FLOOR BEAUTIFUL SCRATCHES, INDENTATIONS AND GOUGES

10 Ways to Prolong the Life of your Carpet

Maintenance and Cleaning Tips MULTICO

COMMERCIAL BUILDING APPLICATIONS

GENERAL RUBBER LINING PRINCIPLES

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

LASER PRINTING PROBLEM SOLVER

BLACK JACK ALL WEATHER ROOF COATING

Minor Cracks in Horizontal Surfaces

did you know? ...you can choose from thousands of carpet and flooring options carpets & flooring FURNITURE & INTERIORS

Technical Services. Product MM INCH Installation direction Seams treatment GTI CONNECT (interlocking)

Slips, Trips and Falls Risk Management Tool

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Mapei systems for radiating floor heating with high thermal efficiency

WOODLINE PARQUETRY 25 Year Warranty

INSTALLATION & CLEANING INSTRUCTIONS FOR SOLUTION-DYED NYLON CARPETS

How To Install Hardwood Flooring

CLEANING INSTRUCTIONS No. 02

Slips Trips and Falls

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Omnisports Vinyl solutions

DIP Online Designs Ink Publishing Article Archive and Reference Library Articles by Chris A. Paschke, CPF GCF

Roof Insulation Building. Energy. Environment friendly e-library

High Performance Building Materials SCREEDS REPAIR MORTARS LEVELLING & SMOOTHING WATERPROOFING TILE ADHESIVES & GROUTS PRIMERS & ADDITIVES

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

Development COMMERCIAL CARPET TILE. Lifetime Commercial Warranty. 18oz/sy - Solution Dyed Twisted Polypropylene JUNE 2014.

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Waterproofing construction Joints

Slip, Trip & Fall Prevention Handbook

How to repair your existing low slope flat roof.

Commercial/Residential Linoleum Sheet Installation System

care instructions for oiled/waxed wood floors

Concrete Resurfacing. System Guide. by Parchem Construction Supplies

The following are just a few of the advantages that Techno-Solis offers you as a solar contractor: Contact Us!

Cleaning guide for senior living facilities

Please calculate with around 5% more square meters than needed because you will have material loss due to cutting and sorting.

Country Series. 12.3mm V-Groove Edge Engineered Laminate Flooring. Laminate Flooring Care and Maintenance. Routine Cleaning

Wood Floor Maintenance

SANS FIRE PERFORMANCE SANS 428 ENERGY SAVER REFLECTIVE TIASA A MEMBER OF 2009/ / / /341

How To Test A Wrap N Drain X Dampproofing System

7.5 There are a number of different types of synthetic surface available. These fall generally under one of the following headings:

METHOD STATEMENT 006 TORCH APPLIED MEMBRANE TO BASEMENT WALLS

THE FAST, EASY AND DURABLE PAVING SUPPORT SYSTEM

Introduction: Consumables - Part of the Identification System

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Armstrong Do-It-Yourself Tile Installation System

Transcription:

Table of contents and general rules The backing is an important part of a carpet; both during daily use and when the carpet has to be fitted. These installation instructions are based on the backing types with which our carpets are delivered. Table of contents: 1. Recommended installation methods for the danfloor backing...page 2 2. Fitting Instruction in general for danfloor carpets...page 3 3. Specific instruction for Domestic-Foam (SG/SV)...Page 4 4. Specific instruction for Domestic-Textile backing (UT)...Page 6 5. Specific instruction for Felt backing (UV)...Page 7 6. Specific instruction for Contract-Foam (KT)...Page 8 7. Specific instruction for Woven textile backing (TD)...Page 9 8. Specific instruction for Flat woven (Classic) and Wilton woven carpets (Master Basic)...Page 10 9. Specific instruction for danfloor Nature Rib (Sisal)...Page 11 As a possible need for preparatory work as well as the choice of fitting method always has to be evaluated in accordance with the local conditions danfloor cannot be held responsible for the performance of the work, whether or not our instructions are followed. The use of adhesives and other materials should always be in accordance with the recommendations of the manufacturer. Because the danfloor backing is an important part of the carpet both as to installation and in use, this instruction is based upon the backing types our carpets are delivered with as standard. Page 1

Methods as to danfloor backing types The fitting instructions are valid for the following products with: A. Domestic foam SG/SV, with/without pattern B. Contract foam backing KT Foam. Woven textile backing TD Textile backing C. Laminated textile backing UT Ultra Light Bac D. Laminated Felt backing UV Ultra Light Vlies E. Tiles Bitumen backing A. WB Contract backing Method (see description) Flat adhesion Wet adhesion Easy release system Wet fixation Tackifying Dry fixation Loose laying On grippers A. SG/SV B. + ++ ++ O + + 1 O KT/TD C. ++ 2 ++ 2 O O O O O/+ D. UT ++ ++ O O O + 3 O/+ E. UV + + O O O + 3 O Bitumen + + O ++ 4 O O O F. O WB O = Not suitable ++ 2 ++ 2 + = Suitable O O ++ = Very suitable (recommended) O O 1. Cuts of less than 25 m 2 are to be edge fixated with tape or adhesive Cuts larger than 25 m 2 should always be full fixated. 2. Cuts of less than 25 m 2 are to be full fixated. Cuts larger than 25 m 2 are be be full fixated. 3. Cuts of less than 25 m 2 can be edge fixated with danfloor Microtape or adhesive. Cuts larger than 25 m 2 should always be full fixated. 4. For fixation of carpet tiles a special fixation adhesive is required. Note! When installing cuts of less than 25 m 2 full fixation should always be applied where the carpet is exposed to extra heavy loads e.g. from castor chairs, traffic with trolleys, pallet trucks or in heavy traffic areas. Description of method: Full fixation: Fixation of the carpet on the whole floor surface, by one of the following methods: Wet adhesion: Fitting with a wet dispersion adhesive applied by a trowel. Easy release system: Fitting with a wet dispersion adhesive applied by a trowel on a slip-primed sub floor. Wet fixation: Fitting with a fixation adhesive applied by a roller. (Only filled sub floor) Tackifying Fitting with a finger dry adhesive. (Only filled sub floor) Dry fixation Fitting on a fully adhered underlay with full surface danfloor Micro-Tape. Loose laying: Loose laid, where the ends and/or edges are fixed with tape, adhesive or danfloor Micro- Tape. On gribbers: Stretching and fastening on grippers with an underlay of felt. Page 2

General guidelines for danfloor Carpets Surface Has to be clean, dry, and uniformly absorbent. Further without oil or grease stains. Pay extra attention when applying a vinyl floor. Has to be level, solid, and firm, without cracks and edges. Heavily absorbent underlay should be preliminary treated with a primer. The humidity of concrete sub floor must not exceed 90% RH. The floor heating has to be turned off and cooled down before the installation and until 2 days after. The installation must take place at the recommended room climate for the glue type, normally 17-25º and a humidity of 35-75% RH. Carpet, Fixation Place the carpet and the materials in the room in question min. 24 hours before fitting is initiated. It is important that the carpet and possible adhesive are acclimatised, especially during the winter months due to fluctuations in temperature. Before cutting the carpet must be inspected for visible faults. In case of such the supplier must be contacted for further agreement before the work is continued. If not we always make a reservation in the treatment of a complaint. Application of adhesives, tapes or other material must always take place in accordance with the recommendations of the manufacturer. Placing of the carpet lengths: If more lengths are to be joint they must be placed in the same direction (note the direction indicator on the back). Only carpet material from the same production has to be applied in the same room. Placing an order of yarn-dyed qualities, i.e. Classic Contract and Master Basic and solution-dyed qualities, a very homogeneous colour progress is ensured and colour differences between the lengths from the same lot will not occur. Placing and order of piece-dyed qualities, i.e. Eton Basic, Eton Ribs, Eton Tweed and Baltic Basic, the fitter is responsible for laying the carpet according to our installation guide. This installation guide is at the same time the production- and colouring order. Hereby we try to ensure that visible colour differences between the carpet lengths do not occur, as from the beginning till the end of a larger colouring procedure a minor colour difference may occur. As a principal rule the lengths have to be installed with the joints perpendicular (90 ) to the most lightgiving window wall. In order to obtain the best result the joints should be avoided in the most exposed places. For instance in doorways, entrances and under castor chairs. When fitting carpets on stairs it should always be protected by nosings. Page 3

After installation After the installation and until in use the carpets should be protected against damage and soiling from traffic and subsequent craftsmen. It is the responsibility of the craftsmen that the covering is properly and in consideration of the strain before use. Under all circumstance the carpet must be protected from direct sunlight during the installation until 2 days after. danfloor Carpets with domestic foam (SG and SV) A danfloor carpet with foam backing is most suitable for most living-quarters with moderate traffic. It gives increased walking comfort and is more absorbent as to steps than carpets with a firmer backing. Installation methods: Loose laying can take place when installing cuts of less than 25 m 2. The loose laying is made by fixing the edges with double adhesive tape in minimum 50 mm width along the end walls. In case of possible joints, double adhesive tape is applied in the middle of the joint, which can be strengthened with a strip on each side. Cuts of more than 25m 2 should always be applied through full fixation. The full fixation can be made by either: Wet adhesions, easy release system, wet fixation or dry fixation. The strongest adhesion is always obtained through the wet adhesion but with regard to the under lay the adhesive is often applied as late wet adhesion in order that the water influence is diminished. danfloor Carpets with domestic textilebacking Ultra Light Bac / Textile (UT) danfloor carpets with UT (Ultra Light Bac ) are most suitable for all living quarters. The backing has been developed especially against the big demands on the environment. The carpets are produced/backed on a unique unit, where the UT textile is laminated to the carpet. The obvious advantages are that the pile content, mother rolls, lamination and UT are polypropylene and recyclable and can be reused for new products after a life as a carpet. Further the method gives larger form stability than similar carpets produced conventionally. Loose laying only to be applied when installing cuts of less than 25 m 2 Double adhesive tape will normally not be sufficiently enough for this backing type. The carpet is thus fixed at the ends by wet fixation. The carpet is fixed to the sub floor in approx. 30 cm. width among the end walls. Joints are also fixed with 30 cm on each side of the joint. As an alternative danfloor Microtape is used for end fixation and joints. Full fixation should be applied when installing cuts of more than 25 m 2 in the same room. Applying wet adhesion or dry fixation can make full fixation by danfloor Microtape. Note! This tape has been developed especially for the UT backing, if other products are used any product guarantee is repealed. Page 4

Wet adhesion is the strongest, but with regard to the sub floor the adhesive is often applied as late wet adhesion in order that the water influence is diminished. The adhesive is applied to the prepared sub floor with a trowel according to the instructions from the supplier. By priming with for instance Casco Slip-Primer 3443 unnecessary damage to a sensitive sub floor is avoided. danfloor Carpets with Ultra Light Vlies /felt (UV) danfloor carpets with UV (Ultra Light Vlies ) are most suitable for all living quarters. The backing has been developed especially against the big demands on the environment. The carpets are produced/backed on a unique unit, where the UV felt is laminated to the carpet. The obvious advantages are that the pile content, mother rolls, lamination and UV felt are polypropylene and recyclable and can be reused for new products after a life as a carpet. Further the method gives larger form stability than similar carpets produced conventionally. Loose laying only to be applied when installing cuts of less than 25 m 2 Double adhesive tape will normally not be sufficiently enough for this backing type. The carpet is thus fixed at the ends by wet fixation. The carpet is fixed to the sub floor in approx. 30 cm. width among the end walls. Joints are also fixed with 30 cm on each side of the joint. As an alternative danfloor Microtape is used for end fixation and joints. Full fixation should be applied when installing cuts of more than 25 m 2 in the same room. Applying wet adhesion or dry fixation can make full fixation by danfloor Microtape. Note! This tape has been developed especially for the UV backing, if other products are used any product guarantee is repealed. Wet adhesion is the strongest, but with regard to the sub floor the adhesive is often applied as late wet adhesion in order to diminished water influence. The adhesive is applied to the prepared sub floor with a trowel according to the instructions from the supplier. By priming with for instance Casco Slip-Primer 3443 unnecessary damage to a sensitive sub floor is avoided. Page 5

danfloor Carpets with contract foam backing (KT) danfloor carpets with contract foam are suitable for most living quarters, i.e stairs and corridors with heavy traffic. danfloor carpets with this backing have been developed especially for the demands on the contract market. These carpets are often used in business premises, offices, hotels, restaurants and cinemas. Typically the carpets have been tested and found suitable for instance for castor chairs, which calls for heavy demands on the carpet (see the technical specifications for each quality) Installation: Full fixation should be applied at all installations. And always when rolling stock such as castor chairs are used afterwards, or if the carpet is exposed to more traffic than in private homes. Full fixation can be made by wet adhesion, easy release or dry fixation. Wet adhesion is the strongest, but with regard to the sub floor the adhesive is often applied as late wet adhesion in order that the water influence is diminished. The adhesive is applied to the prepared sub floor with a trowel according to the instructions from the supplier. Easy release system is used where a quick and economic replacement of a carpet is wanted with a minimum damage to the sub floor. The sub floor is primed with a slip primer. Then dispersion is applied with a trowel. At the following dismounting of the carpets the primer and dispersion adhesive will delaminate which minimise the following preparing of the sub floor. Also follow the instructions of the adhesive supplier. Joints can be very difficult, however skilled craftsmen should not have any problems. Loop products, such as Eton, are installed so that the structure of the loops engages like a zipper. In case of long lengths it is unlikely to keep this effect all through the joint length. The best result is achieved by holding the cutter a bit on the slant against the length, which is to be joined. danfloor Carpets with textile backing(td) danfloor carpets with textile and Ultra Light Bac backings are delivered for both the commercial and domestic market (See the technical data for each quality) Installation: Loose laying is only to be applied when installing cuts of less than 25 m 2. Double adhesive tape will normally not be sufficiently enough for this backing type. The carpet is thus fixed at the edges with glue or installed on grippers. The carpet is glued to the sub floor in approx. 30 cm. width along the end walls. Joints are also glued on approx. 30 cm. on each side of the joint. Full fixation should be applied when installing cuts of more than 25 m 2 in the same room. And always when rolling stock such as castor chairs are used afterwards, or if the carpet is exposed to more traffic than in private homes. Wet adhesion, easy release or dry fixation can make full fixation. Wet adhesion is the strongest, but with regard to the sub floor the adhesive is often applied as late wet adhesion in order that the water influence is diminished. The adhesive is applied to the prepared sub floor with a trowel according to the instructions from the supplier. Page 6

Easy release system is used where a quick and economic replacement of a carpet is wanted with a minimum damage to the sub floor. The sub floor is primed with a slip primer. Then dispersion is applied with a trowel. At the following dismounting of the carpets the primer and dispersion adhesive will delaminate which minimise the following preparing of the sub floor. Also follow the instructions of the adhesive supplier. Joints can be very difficult, however skilled craftsmen should not have any problems. Loop products such as Eton are installed so that the structure of the loops engages like a zipper. In case of long lengths it is unlikely to keep this effect all through the joint length. The best result is achieved by holding the cutter a bit on the slant against the length, which is to be joined. danfloor flatwoven and Wilton woven carpets. danfloor flatwoven (Classic Contract) and Wilton woven (Master Basic) carpets are suitable for every living quarters, hereunder stairs and corridors with heavy traffic. These carpets have been developed especially for the demands on the contract market. Often they are used for business premises, offices, conference rooms, hotels and restaurants. The carpets have been tested and found suitable for caster chairs, which demand a lot from the useful quality. (See the technical data for each quality) The difference between these carpets and tufted carpets is that the yarns are literally woven in between chain, tie and weft yarns. This construction makes the carpets extra durable and with an extreme useful quality. Installation: Sub floor: Flatwoven and Wilton woven carpets are very regular woven, which demands a lot from the sub floor to obtain a good result. The sub floor must be completely flat, because any unevenness will be visible after installation. Thus we recommend that the sub floor be prepared for cracks and unevenness. Full fixation should be applied at all installations. And always when rolling stock such as castor chairs are used afterwards, or if the carpet is exposed to more traffic than in private homes. Wet adhesion, easy release or dry fixation can make full fixation. Wet adhesion is the strongest, but with regard to the sub floor the adhesive is often applied as late wet adhesion in order that the water influence is diminished. The adhesive is applied to the prepared sub floor with a trowel according to the instructions from the supplier. Easy release system is used where a quick and economic replacement of a carpet is wanted with a minimum damage to the sub floor. The sub floor is primed with a slip primer. Then dispersion is applied with a trowel. At the following dismounting of the carpets the primer and dispersion adhesive will delaminate which minimise the following preparing of the sub floor. Also follow the instructions of the adhesive supplier. Joints: Classic Contract - Flat woven Lengths are rolled out with approx. 3 cm overlapping. Then the glue is applied leaving approx. 30 cm edges without glue. Then the cut is made through both layers along a steel rail with a sharp straight cutter. Then the joints match perfectly and the left over 60 cm are glued and rolled. A skilled craftsman can glue both lengths 100% before cutting. Page 7

Joints across are to be avoided, since unweaving is difficult to avoid at flat woven carpets. At for instance pillars or the like the cut is made in the production direction. Master Basic Wilton woven The lengths are delivered with a woven edge, which is cut with a sharp carpet cutter approx. 2 cm from the pile edge by following the burling thread. The lengths are brought together to control that the lengths are on the straight thread. If that is not the case the joint has to be made as mentioned above along a steel rail. It is possible to make joints across, for the skilled craftsman it is possible to make a joint along a steel rail, because carpets such as Master Basic are interwoven. danfloor Sisal Carpets with contract foam backing (SP) danfloor Sisal carpets with contract foam are suitable for most living quarters, i.e stairs and corridors with heavy traffic. danfloor Sisal carpets with this backing have been developed especially for the demands on the contract and domestic market. (see the technical specifications for each quality) It is the experience of the original and simple inspiration from nature which characterize the profile of danfloor Sisal Carpets. Sisal carpets are natural and fashionable. Healthy surroundings All danfloor Sisal carpets are made of vegetable fibre from the Agave-plant. Unique qualities Vegetable fibres have a number of advantages. As an example vegetale fibres can breath; they can absorbe and give off moisture, until they are at balance again. Therefore they contribute to a healty indoor climate. Especially in very warm and dry rooms they work as a free air-conditioning plant. Vegetable fibres give off heat and comfort, they wear well and age in an optical beautiful way, and thanks to the originality and genuineness they make a pleasant climate. Vegetable fibres are good all year, they seem cool in summer and warm in winther. Carpets of vegetable fibres are non static electric, and are therefore suitable in rooms where persons or devices (eg computers) react sensitively to static electric. Another advantage, worth mentioning is that vegetable fibres are sound insulating in other words they have an outstanding sound insulation ability. Installation methods: Cuts should always be applied through full fixation. The full fixation can be made by either: Wet adhesions or easy release system. The strongest adhesion is always obtained through the wet adhesion but with regard to the under lay the adhesive is often applied as late wet adhesion in order that the water influence is diminished. Page 8