PN8600 Serials Product Specification (V1.2) Topvision Technology Co., Ltd
Catalogue Chapter1 Product Introduction... 3 1.1 Product overview... 3 1.2 PN8600 serials OLT Product characteristic... 3 1.3 PN8600 serials OLT Product introduction... 4 1.4 PN8620 serials ONU Product introduction... 5 1.5 PN8640 serials ONU product introduction... 6 Chapter2 Application Scenarios... 8 2.1 Application scene... 8 2.2 FTTX application scene... 8 Chapter3 EMS... 10 3.1 NM3000 NMS Introduction... 10 3.2 NM3000 NMS structure... 10 3.3 NM3000 NMS feature... 10 3.4 NM3000 NMS function demonstration... 12 Chapter4 Technical Index... 14 4.1 PN8601 Specification... 14 4.2 PN8602 Specification... 15 4.3 PN8603 Specification... 17 4.4 PN8620 serials ONU product specification... 19 4.5 PN8640 serials ONU product specification... 20 All right reserved Topvision Technology Co,.Ltd -2- -classified documen
Chapter1 Product Introduction 1.1 Product overview Topvision PN8600 adopts the next generation product architecture leading in the network transmission area, main control and business board adopts double star bus architecture, not only ensures the bandwidth of users, but also ensures fast switch when it fail to work. PN8600 serials product support various types of hot plug interface board, support switch of the key board to achieve 1+1/1:1 protection,prevent single point of failure effectively. According to the needs of different operators, Topvision supply with large, medium and small capacity of OLT equipment, PN8601, PN8603, PN8602 respectively, coordinated with terminal equipment such as ONU/ONT/E 2- CMTS equipment to provide complete FTTX access scheme, satisfied the characteristic demand of the users with voice, data, video business needs. 1.2 PN8600 serials OLT Product characteristic Communication protocol : CTC 3.0 IEEE802.3 IEEE 802.1q IEEE802.1w Ultra-large capacity:rack mount 10GE exchange platform, T level backplane exchange Convergence ratio flexibility:each business card designed by mix insertion, flexibly adjust convergence ratio Multi-business processing:distributed business processing, ten times ability enhancement High reliability:main control and business board adopts double star bus architechture,1+1 hot backup Abundant multicast function:support IGMP V2,1K concurrent multicast group in every PON interface thorough QoS guarantee:support multi-llid,every PON supports 256 logic link All right reserved Topvision Technology Co,.Ltd -3- -classified documen
strong DBA function:dual management model based on SLA and priority, and flexible broadband management ability complete NM function:graphical interface of SNMP network management and supports remote management, convenient operation and maintenance in the future Abundant safety function:arp prevent attacks, CPU regulating protection, Prevent fake users and fake gateway attacks, Intelligence to prevent attacks 1.3 PN8600 serials OLT Product introduction Chart 1 PN8601 Chart 2 PN8602 Chart 3 PN8603 classify Single Detailed name Basic function External interface board Main function is system 1 out of band maintenance Main management, data internet access Main control control MPUA exchange. Supports 4 GE SFP exchange board board redundancy and switch 1 Console protection 1 Reset Business EPON interface Supply EPON access 8 EPON interface EPUB board board function 1 Reset Uplink GEUA GE uplink board Supply GE uplink function 8 GE(4 1000base-T,4 SFP) All right reserved Topvision Technology Co,.Ltd -4- -classified documen
board 1 Reset 1 out of band maintenance internet access,1 Console maintenance serial port(useful when GEUA is the main control board of PN8602) GEUB GE uplink board Supply GE uplink function 8 GE(SFP) 1 Reset 1 out of band maintenance internet access,1 Console maintenance serial port(useful when GEUA is the main control board of PN8602) XGUA 10GE uplink board Supply 10GE optical interface uplink function 2 10GE SFP+ 1 Reset XGUB 10GE uplink baord Supply 10GE fiber interface 4 10GE SFP+ uplink function 1 Reset XGUC 10GE uplink baord Supply 10GE fiber interface 2 10GE SFP+ uplink function 4 GE SFP 1 Reset 1 out of band maintenance internet access,1 Console maintenance serial port(useful when XGUC is the main control board of PN8602) 1.4 PN8620 serials ONU Product introduction PN8620 serials ONU is independent research and development by Topvision, which is mainly used in the broadband access and video monitoring area. The product supplies 1 or 4 GE interface, it has small and compact structure, and built-in L2 exchange function. It is suitable for application in residential area and enterprise access. All right reserved Topvision Technology Co,.Ltd -5- -classified documen
Chart 4 PN8621 Chart 5 PN8622 Chart 6 PN8624 Chart 7 PN8625 1.5 PN8640 serials ONU product introduction PN8640 serials ONU is independent research and development by Topvision, which is mainly used in the broadband access and video monitoring area, supplies 8 16 24 FE interface and 12V AC power interface which is used in emergency. The product is built-in L2 exchange function, which is suitable for MDU application in campus, building and enterprise. Chart 8 PN8641 Chart 9 PN8643 All right reserved Topvision Technology Co,.Ltd -6- -classified documen
Chart 10 PN8647 All right reserved Topvision Technology Co,.Ltd -7- -classified documen
Chapter2 Application Scenarios 2.1 Application scene EPON is a kind of mature optical fiber access network technology, which has been extensively used in the telecommunications network. It integrates many advantages such as low cost, high bandwidth, strong expansibility of PON and Ethernet, etc. Using passive optical fiber transmission, point to multi-point structure, it solves the problems of the active optical network solutions like more fault points, not easy maintenance, high operating costs,etc. For radio, film and television field, the network has been in the two-way broadband development stage, high bandwidth two-way business emerge in large number such as HD video on demand, HD video phone. Most of the high speed data adopt the EPON network for transmission. Passive optical network has gradually replaced active optical network in the telecommunications market. Independent research and development of Topvision EPON series products can be used in a variety of application models to meet market demand in the field of radio and television, electric power and telecommunications 2.2 FTTX application scene Topvision Integrates the advantage of PON technology and data exchange technology, providing customers with a complete FTTC, FTTB, FTTH, EPON + E 2 -CMTS integrated access solutions. The solution which is independent research and development by Topvision, adopts EPON optical access products to provide customers with a higher access bandwidth and better QoS, guarantee the reliability of the network to be telecommunication level and supply the optimal cost. It solves the problems of the active optical network solutions like more fault points, not easy maintenance, high operating costs, etc. All right reserved Topvision Technology Co,.Ltd -8- -classified documen
Solution advantage: High speed processing of business: multi-business processing platform, greatly improve the system processing capacity Large capacity processing: using 10GE exchange platform, T level backplane capacity DBA:support flexible bandwidth allocation and QoS, so as to ensure the quality of service High reliability: control and business adopts the double star structure, passive optical network transmission, optical fiber detection, ensure the safety of the network Operation and maintenance convenience: no need much maintenance because of passive components used in the system transmission XPON compatible platform:system is compatible with EPON 2.5GEPON 10GEPON GPON NGPON platform. All right reserved Topvision Technology Co,.Ltd -9- -classified documen
Chapter3 EMS NM3000 EMS supports unified management for EPON OLT, distributed and integrated CC8800 series products which are all independent research and development by Topvision. This chapter introduces the NM3000 network management system and its features. 3.1 NM3000 NMS Introduction 3.2 NM3000 NMS structure 3.3 NM3000 NMS feature NM3000 has a complete system management, equipment management, topology management, business management, fault management, performance management, security management and configuration management, etc.nm3000 supplies the best business support for the operator, and provides optimization and expansion based on various business. NM3000 for EPON/E 2 -CMTS provides intelligent configuration system, achieve plug-and-play deployment effect, simplify the operation, enhances the working efficiency of the deployment, reduce construction debugging difficult. NM3000 adopts B/S structure, distributed architecture, support ten million lines of large scale network management, realizes object-oriented concurrent multitasking and centralized management and remote management of the equipment. NM3000 provides north interface, which can be connected with the BOSS system, independent work order system, message center etc. Hierarchical topology function: support multi-level regional management, grouping equipment in area, supply optimized automatic topology of a large number of equipment which are in the same area Equipment list mode: support huge equipments list mode, provides a All right reserved Topvision Technology Co,.Ltd -10- -classified documen
quick positioning and associative lookup function Batch management function: support equipment batch management (for example: batch release configuration, equipment batch restart, etc.), and provide abundant conditional options to filter equipment rapidly Pre-configuration/zero configuration: support pre-configured solution, automatic configuration, user-defined configuration solution, make the terminal plug and play, no need site configuration, easy to deploy Chart 3-1 NM3000 NMS Alarm filtering and strategy: take different alarm strategies according to different alarm type and condition Operator customized business: provide business identity management, facilitate the management of the business Customized desktop: support user-defined concern, similar to the Windows desktop function All right reserved Topvision Technology Co,.Ltd -11- -classified documen
3.4 NM3000 NMS function demonstration Network topology management Chart 3-2 NM3000 network topology management Device management main interface Chart 3-3 NM3000 main interface All right reserved Topvision Technology Co,.Ltd -12- -classified documen
OLT parameter configuration Chart 3-4 NM3000 OLT parameter configuration ONU parameter configuration Chart 3-5 NM3000 ONU alarm management All right reserved Topvision Technology Co,.Ltd -13- -classified documen
Chapter4 Technical Index This chapter presents Topvision EPON serials product detailed specification, including the overall dimensions, power supply requirements and performance parameters. 4.1 PN8601 Specification item capacity Slot QoS DBA OAM Uplink interface PON interface Detailed description 488Gbps switch capacity,1200gbps backplane capacity Wire-speed forwarding Support 2 master slots; 16 business slots Every PON interface supports 256 logical link, provides good QoS for users combined with technologies like VLAN,etc Support complete service processing by using multi LLID technology, and take triple churning encryption for each logic link Flexible broadband management ability, effectively improve the utilization rate of broadband. The dual management model based on SLA and priority, effectively guarantees the minimum bandwidth requirements and the low latency requirements of the high-priority service Support ONU automatic discovery, automatic registration, the user link test, automatic alarm in case of fiber breakage and power outrage of the distant ONU ; Support varies of telecom operations, management features such as MAC address binding and filtering, bandwidth control, VLAN, traffic control and so on. GEUA: Support 4 GE RJ45,4 GE SFP ports GEUB: Support 8 GE SFP ports XGUB: Support 4 10GE SFP+ ports XGUC: Support 2 10GE SFP+ ports, 4 GE SFP ports Every EPUB board supply 8 PON interface(sfp optical module),support PX20/PX20+ optical module Maximum transmission distance of PON is 20KM(1:32), 10KM(1:64) Maximum support 16 EPUB board,128 PON interface, 8192 ONU(1:64) All right reserved Topvision Technology Co,.Ltd -14- -classified documen
Control interface NM interface protocols NMS mode RS232 Console(RJ45),for device management 10/100Base-T out of band network management interface,support in-band NM IEEE802.3-2008 EPON CTC V3.0 Support controllable multicast/fixed and flexible QinQ mode/rstp QoS guarantee/flow classification/acl Conform to SARFT EPON MIB Support three layer routing forwarding, static routing, IS-IS, OSPF, etc, support ECMP dynamic load sharing and three layers of protection, support BFD routing backup, VLAN interface and the Loopback interface SNMP/Web/CLI EMC GB 9254-1998 Class A GB/T 17618-1998 Electrical surge protection dimension weight power Maximum power consumption Work environment YD/T 1082-2000 wide high deep:483mm 575mm 280mm <45kg DC -48V o rac220v,30a overcurrent protection 800W 0~40ºC (70~106kPa) Relative humidity 10%~90%(no condensation) 4.2 PN8602 Specification item capacity Slot QoS DBA Detailed description 56Gbps core exchange capacity,50gbps backplane exchange capacity Non-blocking full speed exchange Support 2 master slots; 16 business slots Every PON interface supports 256 logic link, provides good QoS for users combined with technologies like VLAN, etc. Support complete service processing by using multi LLID technology, and take triple churning encryption for each logic link Flexible broadband management ability, effectively improve the utilization rate of broadband. The dual All right reserved Topvision Technology Co,.Ltd -15- -classified documen
OAM Uplink interface PON interface Control interface NM interface Protocol NM mode Electrical protection dimention Weight power Power consumption Work environment surge management model based on SLA and priority, effectively guarantees the minimum bandwidth requirements and the low latency requirements of the high-priority service Support ONU automatic discovery, automatic registration, the user link test, automatic alarm in case of fiber breakage and power outrage of the distant ONU ; Support varies of telecom operations, management features such as MAC address binding and filtering, bandwidth control, VLAN, traffic control and so on. GEUA: Support 4 GE RJ45,4 GE SFP ports GEUB: Support 8 GE SFP ports XGUC: Support 2 10GE SFP+ ports, 4 GE SFP ports Every EPUB board supply 8 PON interface(sfp optical module),support PX20/PX20+ optical module Maximum transmission distance of PON is 20KM(1:32), 10KM(1:64) Maximum support 2 EPUB board,16 PON interface, 1024 ONU(1:64) RS232 Console(RJ45),for device management 10/100Base-T out of band network management interface,support in-band NM IEEE802.3-2008 EPON CTC V3.0 Support controllable multicast/fixed and flexible QinQ mode/rstp QoS guarantee/flow classification/acl Conform to SARFT EPON MIB Support three layer routing forwarding, static routing, IS-IS, OSPF, etc, support ECMP dynamic load sharing and three layers of protection, support BFD routing backup, VLAN interface and the Loopback interface SNMP/Web/CLI YD/T 1082-2000 wide high deep:483mm 88mm 370mm <10kg DC -48V or AC220V,30A overcurrent proteciton 120W 0~40ºC (70~106kPa) Relavite humidity 10%~90%(no condensation) electromagnetic GB 9254-1998 Class A GB/T 17618-1998 All right reserved Topvision Technology Co,.Ltd -16- -classified documen
compatibility 4.3 PN8603 Specification item capacity Slot QoS DBA OAM Uplink interface PON interface Control interface NM interface protocol Detailed description 488Gbps core exchange capacity,1200gbps backplane exchange capacity Non-blocking full speed exchange Support 2 master slots; 16 business slots Every PON supports 256 logic link, provides good QoS for users combined with technologies like VLAN, etc. Support complete service processing by using multi LLID technology, and take triple churning encryption for each logic link Flexible broadband management ability, effectively improve the utilization rate of broadband. The dual management model based on SLA and priority, effectively guarantees the minimum bandwidth requirements and the low latency requirements of the high-priority service Support ONU automatic discovery, automatic registration, the user link test, automatic alarm in case of fiber breakage and power outrage of the distant ONU ; Support varies of telecom operations, management features such as MAC address binding and filtering, bandwidth control, VLAN, traffic control and so on GEUA: Support 4 GE RJ45,4 GE SFP ports GEUB: Support 8 GE SFP ports XGUB: Support 4 10GE SFP+ ports XGUC: Support 2 10GE SFP+ ports, 4 GE SFP ports Every EPUB board supply 8 PON interface(sfp optical module),support PX20/PX20+ optical module Maximum transmission distance of PON is 20KM(1:32), 10KM(1:64) Maximum support 6 EPUB board,48 PON interface,3072 ONU(1:64) RS232 Console(RJ45) 10/100Base-T out of band NM,support in band NM IEEE802.3-2008 EPON CTC V3.0 Support controllable multicast/fixed and flexible QinQ mode/rstp All right reserved Topvision Technology Co,.Ltd -17- -classified documen
NM mode Electrical surge protection dimention weight Power Power consumption Work environment QoS guarantee/flow classification/acl Conform to SARFT EPON MIB Support three layer routing forwarding, static routing, IS-IS, OSPF, etc, support ECMP dynamic load sharing and three layers of protection, support BFD routing backup, VLAN interface and the Loopback interface SNMP/Web/CLI YD/T 1082-2000 wide high deep:483mm 267mm 260mm <20kg DC -48V or AC220V,30A overcurrent protection 400W 0~40ºC (70~106kPa) Relative humidity 10%~90%(no condensation) EMC GB 9254-1998 Class A GB/T 17618-1998 All right reserved Topvision Technology Co,.Ltd -18- -classified documen
4.4 PN8620 serials ONU product specification ONU model parameter PN8621 PN8622(outdoor model) PN8624 PN8625(outdoor model) Uplink interface 1 PON 1 PON 1 PON 1 PON Ethernet interface protocol 1 10/100/1000Base-T (self-adaption) IEEE802.3-2008 EPON CTC V2.1/3.0 Support controllable multicast/fixed and flexible QinQ mode/rstp QoS guarantee/flow classification/acl Conform to EPON MIB 1 10/100/1000Base-T (self-adaption) IEEE802.3-2008 EPON CTC V2.1/3.0 4 10/100/1000Base-T (self-adaption) 4 10/100/1000Base-T (self-adapiton) Support controllable multicast/fixed Support controllable multicast/fixed Support controllable multicast/fixed and flexible QinQ mode/rstp QoS guarantee/flow classification/acl Conform to EPON MIB IEEE802.3-2008 EPON CTC V2.1/3.0 and flexible QinQ mode/rstp QoS guarantee/flow classification/acl Conform to EPON MIB IEEE802.3-2008 EPON CTC V2.1/3.0 and flexible QinQ mode/rstp QoS guarantee/flow classification/acl Conform to EPON MIB NM mode SNMP/Web/CLI SNMP/Web /CLI SNMP/Web /CLI SNMP/Web /CLI Electrical surge protection YD/T 1082-2000 YD/T 1082-2000 YD/T 1082-2000 YD/T 1082-2000 weight <0.5kg <1kg <0.5kg <1kg power 12V DC 220V AC or 60V AC 12V DC 220V AC or 60V AC Power consumption Work temperature <6W <10W <6W <10W -10 ºC~55ºC -25 ºC~70ºC -10 ºC~55ºC -25 ºC~70ºC All right reserved Topvision Technology Co,.Ltd -19- -classified document
Work humudity EMC Relative humidity 10%~90%(no condensation) GB9254-1998 Class A GB/T17618-1998 Relative humidity 10%~90%(no condensation) GB9254-1998 Class A GB/T17618-1998 Relative humidity 10%~90%(no condensation) GB9254-1998 Class A GB/T17618-1998 Relative humidity 10%~90%(no condensation) GB9254-1998 Class A GB/T17618-1998 4.5 PN8640 serials ONU product specification ONU model parameter PN8641 PN8643 PN8647 Uplink interface 1 PON 1 PON 1 PON Ethernet interface 8 10/100Base-T(self-adaption) 16 10/100Base-T(self-adaption) 24 10/100Base-T(self-adaption) protocol IEEE802.3-2008 EPON CTC V2.1/3.0 Support controllable multicast/fixe and flexible QinQ mode/rstp QoS guarantee/flow classification/acl Conform to EPON MIB IEEE802.3-2008 EPON CTC V2.1/3.0 Support controllable multicast/fixe and flexible QinQ mode/rstp QoS guarantee/flow classification/acl Conform to EPON MIB IEEE802.3-2008 EPON CTC V2.1/3.0Dt Support controllable multicast/fixe and flexible QinQ mode/rstp QoS guarantee/flow classification/acl Conform to EPON MIB NM mode SNMP/Web/CLI SNMP/Web/CLI SNMP/Web/CLI Electrical surge protection YD/T 1082-2000 YD/T 1082-2000 YD/T 1082-2000 weight <1.2kg <2.0kg <2.2Kg power 220V AC 220V AC or DC12V backup power 220V AC or DC12V backup power Power <10W <10W <10W All right reserved Topvision Technology Co,.Ltd -20- -classified document
consumption Work temperature Work humidity -10 ºC~55ºC -10 ºC~55ºC -10 ºC~55ºC Relative humidity 10%~90%(no condensation) Relative humidity 10%~90%(no condensation) Relative humidity 10%~90%(no condensation) EMC GB9254-1998 Class A GB/T17618-1998 GB9254-1998 Class A GB/T17618-1998 GB9254-1998 Class A GB/T17618-1998 All right reserved Topvision Technology Co,.Ltd -21- -classified document