Model SRMD Setra Remote Monitoring Display

Similar documents
Advantium 2 Plus Alarm

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

PagePac PAGEPAL V


LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

PK5500 v1.1 Installation Instructions

User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

IR Repeater. Operation Manual P8620

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual


WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Comfort Control Relay Panel (CCRP)

INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007

LCD5500Z / PKP-LCD v3.x Installation Instructions

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Water Leak Detection System

Installation and Operation Guide PD4600 Series Converter Replacement

InHome Water Leak Detection Package

Y7230A CO 2 Alarm System

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Part I - Installation

BroadBand PowerShield. User Manual

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

MTX-D, Oil Temperature/Pressure Gauge

ELECTRIC FENCE ENERGISER

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

Signal Manager Installation and Operation Manual

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

INSTALLER S & OWNER S MANUAL

16/32 Channel 1U Rack Mount CCTV Power Supply

Service & Parts Manual

Single Station Remote Alarm

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

SENTRY SECURITY MODULE

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

POWER GEAR SLIDE OUT MANUAL

T-Extender E-Extender

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

XTEND 900 MHZ WIRELESS MODEM For use with VEEDER-ROOT EMR³ DATALINK INSTALLATION INSTRUCTIONS Manual , Rev. B

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

INSTRUCTION MANUAL MODEL PCD-88

RGC-IR Remote Gas Calibrator for IR400

TWO/FIFTY/TWO STEREO POWER AMPLIFIER

for DNE-K07 Reference and Installation Manual

Limited Warranty Letter for BYD Photovoltaic Module

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

ATS Overhead Table Shelf System INSTRUCTION MANUAL

Voice Dialer System & Power Monitor VD-5100-SM

User Guide. HDMI Active Cable Extender. DVI-7370c

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Zetron Desktop Microphone Manual F

Architect/Contractor Information Package

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

Single Port T1/E1 Tap

FXM Communication Manual

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

HotLok Pass Through Blanking Panel

Powerware Relay-Serial Card User s Guide

APG-XT APG-HPD. Operating Manual. Internal APG (Analog Programming) Interface for XT/HPD Series Programmable DC Power Supply

GPS 35 USB. installation and quick start guide

VK-250 WARRANTY REGISTRATION FORM

Data Entry Foot Switch Operation Manual

Extender for HDMI 1.3 over CAT6. GTV-HDMI1.3-CAT6 User Manual.

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

PowerStar Mini Triple Play TM

One-Year Consumer Limited Warranty

AS-801 Promotion-On- Hold Segregator. Version 2.10

Leak Detection System

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

INSTALLATION INSTRUCTIONS BOOST CONTROLLER. Pro Control Input (Optional) Tach. Signal. Speed. Gray. Signal. Green Blue. Orange.

Contents. Document information

SURROUND MASTER. User Manual 1.0. English. Copyright 2012 Involve Audio

Model SPDT Relays

2015 PRICE LIST. PRICING EFFECTIVE JULY 06, Rev. 1.3/07-15 Supersedes Price List April 1, 2014, Rev. 1.2/02-15

CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

Component With Audio. Model # COMP-2-HDMI-AD USER MANUAL.

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

Table of Contents. HDMI to 3G/HD/SD SDI Converter Box DVC 3GTx Manual. Introduction 3. System 5. Instruction 6. Dimensions 8. Mounting (Optional) 8

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Unattended Answering Device Instruction Manual

Operation and Installation Manual

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

AR-721U/721K/661U User s Guide

Transcription:

Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for visibility at a distance. Before installing, please check the box and ensure the following items are included: Mounting Plate Grommets for Faceplate/Bezel Faceplate/Bezel Engineering Unit Labels Fig. 1. 1. Mounting Plate (with single or dual display in color(s) ordered: green, red, or blue) 2. Faceplate Bezel (White or Metallic Finish, as ordered) 3. Engineering units label set Note: If a dual display is ordered with a SRH temperature or humidity sensor and a color specified to match each (or your own sensors), wire the correct sensor to the correct display. The SRMD can be powered by 24 VAC/DC and can accept 0 to 5 or 0 to 10 VDC transducer signals from remote sensors. These field sensors can be temperature, humidity, CO2, etc.

2.0 INSTALLATION 2.1 Rough-In (see Fig 2.) Install the SRMD in a 4 11/16 square electrical box. Run the power and signal wiring into the box. Two wires are for the 24 VAC/DC power, and two wires are for each of the signal lines from the field sensors to the display. For example, the single display version would be 2 wires and the dual display needs 2 wires for each of the two displays. Run the wiring to the 24 VAC/DC source and to the sensors that are to be monitored. The power to the sensors is not supplied by the displays. 2.2 Positioning the Front of the Electrical Box It is very important that the box be set 1/16 to 1/8 below the finish wall so that the faceplate will seal against the finished wall. If possible allow for adjustment at the finish stage to set the depth correctly. Fig. 2

3.0 WIring to the Displays Shown in Fig. 3 is a wiring diagram and picture of the back of the mounting plate. Note that each display has a terminal strip. If you are using field sensors that are not Setra s SRH humidity/temperature sensors, then calibrate the display according to Section 4 before completing the wiring shown here. Input Wiring Wiring: +E - Excitation, 24 VAC COM - 2 terminals connected together, wire to 24 VAC and to common of the field sensor +S - wire to the field sensor Fig. 3

4.0 CALIBRATION Power the display(s). If you have the Setra humidity and temperature sensor, then the displays are already calibrated and ready to use. If you are using other sensors, then you must calibrate the displays output signal to the engineering units, unless your sensors are 0 to 5 or 0 to 10 V output and display 0 to 100 (factory default setting). Calibration requires a calibrated Voltage Source to simulate the sensor analog output. Set range dip switch to either 5 V (for a 0 to 5 V input ) or 10 V (for a 0 to 10 V input) position. The factory default calibration of the display is 0 to 5 VDC field sensor input, which will produce a display reading of 0.0 at 0 V and 100.0 at 5 V. Also, if the range jumper switch is set to the 10 V input position, then the calibration will be 0.0 to 0 V and 100.0 at 10 V. Input Wiring Fig. 4

4.2 Zero and Span Calibration Set the Voltage Source to 0 VDC and Connect the Voltage Source to the +S and COM terminals on the display. Check the field sensor input and output specification. Example: Humidity Sensor Temperature Sensor 0-100% RH and 0 to 5 VDC output 50-90 F and 0 to 10 VDC output Setup Humidity Sensor: Apply 0 V and if necessary turn the ZERO potentiometer (pot) until the display reads 0.0, apply 5 VDC and turn the pot labeled 5V until the display reads 100.0 Setup Temperature Sensor: Move the range jumper from the 5V to 10V position. Apply 0 VDC and turn ZERO pot until the display reads 50.0, apply 10V and turn 10V pot until display reads 90.0 4.3 Adjust Display Brightness While looking at the display, turn the Display brightness adjust pot, (See Fig. 4) to the desired brightness.

5.0 INSTALL MOUNTING PLATE After adjusting and verifying the depth of the electrical box relative to the finish wall (see, Fig. 2), install the mounting plate to the electrical box. Be sure that the displays are installed right side up. Install the 2 mounting screws to secure the mounting plate to the electrical box. Fig. 5

6.0 INSTALL FACEPLATE There are 4 pins on the back of the faceplate. Align the pins with the rubber grommets in the mounting plate. Slowly and evenly push the bezel until the back of the bezel is flush against the finish wall. Choose the appropriate Engineering unit labels for the display(s) and place them where you want them on the faceplate. Labels Fig. 6

7.0 RETURNING PRODUCTS FOR REPAIR When returning a product to Setra Systems, the material should be carefully packaged and shipped prepaid to: Setra Systems, Inc. 159 Swanson Road Boxborough, MA 01719-1304 Attn: Repair Department To assure prompt handling, please refer to return instructions on our Web site at http://www.setra.com/tra/repairs/cal_rep.htm. 8.0 WARRANTY AND LIMITATION OF LIABILITY SETRA warrants its products to be free from defects in materials and workmanship, subject to the following terms and conditions: Without charge, SETRA will repair or replace products found to be defective in materials or workmanship within the warranty period; provided that: a) the product has not been subjected to abuse, neglect, accident, incorrect wiring not our own, improper installation or servicing, or use in violation of instructions furnished by SETRA; b) the product has not been repaired or altered by anyone except SETRA or its authorized service agencies; c) the serial number or date code has not been removed, defaced, or otherwise changed; and d) examination discloses, in the judgment of SETRA, the defect in materials or workmanship developed under normal installation, use and service; e) SETRA is notified in advance of and the product is returned to SETRA transportation prepaid. Unless otherwise specified in a manual or warranty card, or agreed to in writing and signed by a SETRA officer, SETRA pressure, humidity, and acceleration products shall be warranted for one year from date of sale. The foregoing warranty is in lieu of all warranties, express, implied or statutory, including but not limited to, any implied warranty of merchantability for a particular purpose. SETRA s liability for breach of warranty is limited to repair or replacement, or if the goods cannot be repaired or replaced, to a refund of the purchase price. In no instance shall SETRA be liable for incidental or consequential damages arising from a breach of warranty, or from the use or installation of its products. No representative or person is authorized to give any warranty other than as set out above or to assume for SETRA any other liability in connection with the sale of its products. For all CE technical questions, contact Setra Systems, USA. EU customers may contact our EU representative Hengstler GmbH, Uhlandstr 49, 78554 Aldingen, Germany (Tel: +49-7424-890; Fax: +49-7424-89500). 159 Swanson Road, Boxborough, MA 01719-1304 Tel: 800-257-3872/978-263-1400 Email: sales@setra.com; Web: www.setra.com SS-SRMD Rev. A 11/13/12