The Development of Heat Pump Water Heaters Using CO 2 Refrigerant



Similar documents
Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

HFCS, REFRIGERATION AND AIR-CONDITIONING: MINIMISING CLIMATE IMPACT, MAXIMISING SAFETY

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

Part A: Fluid properties

AIR REVERSING R744 AIR CONDITIONING SYSTEM

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

LG Electronics AE Company, Commercial Air Conditioning

A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential

R-32. The next generation refrigerant for air conditioners and heat pumps

THE REPLACEMENT OF R-22

HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS

How To Calculate The Performance Of A Refrigerator And Heat Pump

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Mohan Chandrasekharan #1

Research on the Air Conditioning Water Heater System

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

UNIT 2 REFRIGERATION CYCLE

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

R-32. The next generation refrigerant for air conditioners and heat pumps. Superior energy efficiency and low GWP

Chapter 3.4: HVAC & Refrigeration System

New Trends in the Field of Automobile Air Conditioning

Low GWP Replacements for R404A in Commercial Refrigeration Applications

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

Refrigerant Choices for Commercial Refrigeration. Finding the Right Balance

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

Applications in Mobile Air-Conditioning and Applications in Heat Pumps

Certification in the safe and efficient use of alternative refrigerants

8. Heat pumps, heat pipes, cold thermal energy storage

News in Data Center Cooling

High Pressure Ammonia Systems New Opportunities

CHAPTER 9: WATER HEATING

Daikin Altherma hybrid heat pump. The natural combination

Final Report by Air Conditioner Evaluation Standard Subcommittee, Energy Efficiency Standards Subcommittee of the Advisory Committee for Natural

2010 Report of the Refrigeration, Air Conditioning and Heat Pumps Technical Options Committee (RTOC)

Elements Elements describe the essential outcomes.

Daikin Altherma. hybrid heat pump. The natural combination

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight Temperature glide o C Boiling point (1 atm)

Testing methods applicable to refrigeration components and systems

GEOTHERMAL HEATING AND COOLING INTRODUCTION

ENERGY SAVING BY COOPERATIVE OPERATION BETWEEN DISTRICT HEATING AND COOLING PLANT AND BUILDING HVAC SYSTEM

GEOTHERMAL HEAT PUMP SYSTEMS ARE RED HOT BUT ARE THEY REALLY GREEN?

Basic Operating Characteristics of CO2 Refrigeration Cycles With Expander-Compressor Unit

Building Energy Systems. - HVAC: Heating, Distribution -

Ambient Energy Fraction of a Heat Pump

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

Optimization of Water - Cooled Chiller Cooling Tower Combinations

EU F-Gas Regulation Guidance Information Sheet 5: Stationary Air-conditioning and Heat Pumps

Putting a chill on global warming

Refrigeration and Air Conditioning with Reduced Environmental Impact

Commercial Gas Heat Pump - VRF

Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling

REFRIGERATION (& HEAT PUMPS)

Automobile Air Conditioning Primer

SOLAR COOLING WITH ICE STORAGE

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Hybrid heat pumps. saving energy and reducing carbon emissions

Drives and motors. A guide to using variable-speed drives and motors in retail environments

Commercial Hot Water. Make a difference...

COURSE TITLE : REFRIGERATION AND AIR CONDITIONING COURSE CODE : 4029 COURSECATEGORY : A PERIODS/WEEK : 5 PERIODS/SEMESTER : 90 CREDITS : 4 OBJECTIVES

Study on Performance Evaluation of a Split Air Conditioning System Under the Actual Conditions

Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Waste Heat Recovery through Air Conditioning System

Glossary of Heating, Ventilation and Air Conditioning Terms

Continuous flow direct water heating for potable hot water

CLIMATE CHANGE POLICY FRAMEWORK FOR REFRIGERATION AND AIR CONDITIONING SECTOR

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System

Energy Efficiency Best Practice Guide Industrial Refrigeration

DAikin Altherma low temperature heat pump. end user leaflet

Combination Ductless Heat Pump & Heat Pump Water Heater Lab and Field Tests

Cooling kw Heating kw

The phase out of R22. Phase out of HCFCs

RS-24 (R426A): Q & A

Heat Recovery In Retail Refrigeration

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

How to choose a heat pump and use it wisely

Air-Conditioning Buying Guide

Energy-efficient Products for Better use of Energy in the Home

Air-cooled Chillers with High Speed Centrifugal Compressors

SEERS International. Hybrid Hot Water Systems. Innovation Technology

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS

Guide to good leak testing

How Ground/Water Source Heat Pumps Work

Refrigeration Basics 101. By: Eric Nelson

Optimization of combined heating and cooling in Supermarkets

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Natural geothermal energy.

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Why and How we Use Capacity Control

P08 Köldmedier med låg växthuseffekter

Guidance for Mobile Air Conditioning (MAC) Sectors. Guidance: F Gas and Ozone Regulations Information Sheet MAC 3: Key Obligations

Industry insight. Refrigerant gases: an industry in transition.

Transcription:

The Development of Heat Pump Heaters Using CO 2 Refrigerant Shigeharu TAIRA* * DAIKIN Industries, Ltd., 1000-2 Aza-Ohtani, Okamoto-cho, Kusatsu, Shiga 525-8526 Abstract heating consumes about one-third of total residential energy in Japan. Therefore, addressing the carbon dioxide (CO2) emissions from this energy use is one of the top priorities for Japan in order to mitigate climate change. Further, heat pumps that rely on HFCs pose another problem in the form of direct greenhouse gas emissions, due to their high GWPs. To reduce energy and minimize emissions of both greenhouse gases and ozone depleting substances, CO2 was chosen as a refrigerant. This paper describes how the properties of CO2 are not only suitable for hot water heaters, but why CO2 is actually preferred because of the electric power generating composition and resulting charge rate structure in Japan. It also discusses the latest product development and describes Japanese national policy to expand the use of this type of product in order to reduce climate emissions. Key words: heat pump water heater, natural refrigerant, CO2, COP 1. Introduction Recently, there has been a move towards energy saving design and the use of natural refrigerants over fluorocarbons in refrigeration, air-conditioning, and water heating equipment in order to protect the ozone layer and address global warming. Regarding refrigerants, in particular, research has been actively underway in Europe to use natural substances (e.g., ammonia, hydrocarbons, CO2) to replace HFC refrigerants, which contribute to global warming. In Japan, roughly one-third of the energy consumed by households is used for water heating, as shown in Figure 1. More than 90 percent of this total is accounted for by combustion type water heaters. Hence, increasing the energy-efficiency of water Heating, cooling: 26% Kitchen: 6.2% Hot water supply: 30.7% heaters is an important measure to reduce CO2 emissions from this source, and a key priority for the Japanese government (including the New Energy and Industrial Technology Development Organization [NEDO]), power companies, manufacturers, and others towards reducing emissions by 2010. Lighting, household electrical appliances, etc: 36.8% Figure 1. Household energy consumption in Japan (Extract from a catalogue of Daikin of Feb. 2008) Power generation systems tend to generate excess power at night. Therefore, to reduce energy consumption in Japan, power companies promote the use of electricity at night for power load equalization. An efficient thermal storage system using night-time electric power is ideal for this situation, and a high-efficiency heat pump has the potential to fill this role. However, for heat pumps to be most effective in reducing greenhouse gas emissions, they must not only be efficient in their energy use, they must also move away from reliance on HFCs a key refrigerant used in the air conditioning and refrigeration sector. Although research into CO2 refrigerant is currently underway (especially in Europe), it is not yet considered to be practical; mass production of CO2 in air conditioning units has not yet become a reality. However, CO2 refrigerant used for water heating has the possibility to offer performance equal to or greater than that of HFCs. That is why the Japanese government, as its national policy, has provided subsidies since September 2002 for introducing CO2 refrigerant heat pump water heaters, with the goal of expanding the market in Japan. At the same time, power companies are involved in the development and promotion of high-efficiency electric

water heaters designed to improve electric power load equalization by operation at night. Against such a background, Daikin has developed a swing compressor design to match the characteristics of CO2 natural refrigerant, as well as a residential CO2 heat pump water heater (hereafter referred to as a CO2 water heater) that includes a water heat exchanger. This paper describes these new products. 2. Refrigerant characteristics Studies were conducted to compare the performance of non-fluorocarbon refrigerants (e.g., CO2) to HFC refrigerants, namely R-410A (HFC32/125=50/50wt%) and R-407C (HFC32/125/134a=23/25/52wt%) for use in residential heat pump water heaters. Table 1 presents the characteristics of the HFCs and R-744 (CO2). As shown, R-410A and R-407C have somewhat higher COP but far higher GWP than R-744. Refrigerant Practical examples of commercialization Table 1. Refrigerant characteristics HFC Natural refrigerant R410A R407C R744(CO2) RAC PAC Commercial Heater PAC Chiller Commercial Heater Residential Heater (Eco Cute) & Commercial Heater ODP 1 0 0 0 GWP 2 1975 1652.5 1 Combustible No No No Toxic Pressure (MPa) (low/ high) 2.7/3.0 1.8/2.0 9.5/11 COP(compared to R410A) (low/high) 100 95/100 60/80 Note: RAC= residential air-conditioning; PAC= packaged air-conditioning. 1 Ozone depletion potential 2 Global warming potentials are based on IPCC 2001. Standard electric water heaters in Japan heat water from 10 C to 65 C in a single-pass system. Figure 2 (a) and (b) are temperature-heat (T-Q) lines showing the relationship of heat value and temperature of a heat pump water heater. As shown in Figure 2 (a), HFCs heat low-temperature water by high condensing temperature, so irreversible heat loss is unavoidable and the theoretical performance is low 1. A heat pump cycle with a multistage compressor can reduce the loss, but cost increases due to complications of the cycle and other technical problems must be addressed. Conversely, as shown in Figure 2 (b), a CO2 heat pump that heats water using supercritical CO2 efficiently heats water from low to high temperatures in the most basic single-stage compressor cycle. Fluid in a supercritical condition does not undergo a phase change, so the temperature of CO2 drops gradually as the water is heated; the temperature difference between water and CO2 is almost unchanged while heat is exchanged. This means a smaller irreversible loss in the water heat exchanger that exchanges heat between water and refrigerant. HFCs Temp. Temp. CO2 Heat value Heat value (a) 1-Stage Cycle using HFCs. (b) Trans-Critical Cycle using CO2 Figure 2. T-Q Diagram about Heat Pump Heating This is the main reason why CO2 refrigerant is suitable for water heaters and other single-pass heating applications with large temperature differences, which heat water from low- to high temperatures. As Table 1 shows, suitable refrigerants must be selected for different applications, i.e., HFCs are suitable for residential

air conditioners and packaged air conditioners, while CO2 is suitable for water heaters. 3. Advantages of CO2 water heater Figure 3 presents CO2 water heaters. The systems consist of three-unit components: the heat pump unit, the hot water storage unit and the remote controller. The heat pump unit draws heat from the atmosphere, compresses the heated refrigerant to heat it further, and transfers the heat to water to make it hot. The storage unit stores the hot water. The remote controllers installed in the kitchen and the bathroom enable the user to draw hot water when needed. The advantages of the CO2 water heater are that: (1) both the ODP and GWP of the refrigerant are 0; (2) it Kitchen RC Bathroom RC can heat water up to 90 without a heater (see Figure 4); Heat pump unit Hot water storage tank (3) the heat pump method offers energy saving and safety; Figure 3. CO2 water heaters and (4) it is of the night-time thermal storage type, contributing to electric power load equalization in Japan 2. pressure In addition, a CO2 heat pump water heater can boil over 10 MPa Super-criticality region additional water more efficiently than traditional electric water heaters of night-time thermal storage type. Based on design requirements, the size of the tank can be reduced, so critical point the 370 L tank has grown to be more popular than the 460 L tanks of most traditional electric water heaters. Hot water is typically used differently by Japanese households compared to other countries. The Japanese are the fondest of bathing in the world. Given this, they need a large amount of hot water at one time to fill a bath almost Enthalpy (kj/kg) everyday. The quantity used for this purpose is double that Figure 4. P-h lines of CO2 refrigerant in Western countries. On the other hand, the hourly water heating capacity of most CO2 water heaters is lower than that of combustion type water heaters due to cost Daytime Summer: 29.76/kWh considerations. Accordingly, it is hard to heat a large Other seasons: 27.06/kWh amount of water at one time using a CO2 water heater. This Living time Living time means that, if a large amount of hot water is required at 20.67/kWh 20.67/kWh one time, it is more cost-effective to heat water in advance. Considering these conditions, in order to achieve a system Night time 7.22/kWh favorable to both consumers and electric power companies, and to compensate for the drawbacks of a heat pump, the heat pump unit is run at night, when electric power is cheaper to pool hot water in the tank and provide it in the Time (O clock) daytime 3 Figure 5. Electricity rates by season and time. Figure 5 shows the typical electricity usage of (KANSAI ELECTRIC POWER CO.) Japanese homes. The CO2 water heater has been designed to maximize the benefit of this kind of rate system, which promotes the use of electricity at night for power load equalization. Price ( /kwh) Pressure (MPa) 4. Technological development of major components New compressors and water heat exchangers were the major components developed for heat pump units of

CO2 water heaters. These components are outlined below. 4.1 Swing compressor In a CO2 water heater that is heating water to a high temperature, the pressure on the high pressure side of the refrigeration cycle is typically more than three times that of R-410A used in an air conditioner. Therefore, when a conventional rotary compressor is used, the reduction in compressor efficiency caused by internal leaking and the reliability of the sliding area on high differential pressure become concerns. Figure 6 shows the structure of a conventional rotary compressor and our developed swing compressor. With a rotary compressor, imposing a vane on the roller by pressure difference (between high pressure and the pressure in the compressor chamber) results in areas of high and low pressure, as shown in Figure 6. Combined vane and roller At the tip of vane: No wear, improved reliability, improved Because the differential pressure is several wear, burn gas leak performance due to less leakage times larger in a CO2 water heater, wear or Swing burning at the tip of the vane causes Vane Bush problems; due to the increase in differential Compression chamber Intake pressure and the speed of sound, internal gas Roller leakage across the vane from the high to low pressure areas increases. To address this, the Daikin swing compressor combines a vane and roller, as shown in Figure 6. With the Piston Crankshaft Crankshaft swing compressor, there is no sliding between the vane and roller, so they do not wear, Figure 6. Comparison of conventional rotary and swing compressors thereby eliminating gas leakage through the gap. Due to these characteristics, a swing compressor can perform superbly with CO2. 4.2 heat exchanger Generally, a double tube construction is used in water heat exchangers. When this is applied to heat pump water heaters, a leakage detection ditch is added to prevent mixture of refrigerants or oil and water in the event of refrigerant leakage (see double tube shown in Table 2). However, this type of double tube has the drawbacks of being heavy, expensive, and difficult to reduce in size because the bending R cannot be reduced. To address this, Daikin developed a new heat exchanger with a capillary tube acting as a flow channel for CO2 (see smooth tube shown in the table 2), wound around the core pipe as water flow and both brazed. The shape of the water heat exchanger is presented in Figure 7. As shown, the core pipe is wound on a plane surface, and the wound pipe is arranged to produce a double layer. Therefore, the weight and volume of the water heat exchanger is about 10 to 30% less than those of a double-tube exchanger. For further energy conservation, a Table 2. Comparison of water heat exchanger Former type New type Spec Double tube Smooth tube(initial time) Dimple tube(latest) CO2 Outline of shape Dw,i p CO2 refrigerant piping piping Leckage detection ditch CO2 Dimple Capacity ratio 1.00 0.89 0.89 Weight ratio 1.00 0.74 0.64 Performance 1.00 1.00 1.00

water heat exchanger using an innovative dimple water tube was developed. The improvement in performance was proven by the time-series images of the dimple tube. By using the dimple tube, the heat transfer performance is doubled compared to a smooth tube. The accelerated heat transmission can be seen especially in the low Reynolds number field 4. Figure 7. Photo of appearance of water heat exchanger 5. Steps for the next generation CO2 water heater A number of technological challenges still need to be resolved for water heaters. Two characteristics in Heating Capacity high particular the use of ambient air as a heat source, Traditional Cycle and the storage of hot water are problematic when iso-entropic larger capacity is required. In Japan s high density P expansion urban areas, space is at a premium. The development of compact products to fit tight space will be critical for future expansion of the CO2 water heater market. In addition, in order to improve performance of CO2 water heaters, Daikin is developing an expander to recover Energy energy in the process of expansion of refrigerant, Recovered by which is currently believed to be the most effective low Input way to improve the efficiency of the CO2 cycle. 5 Figure low h Enthalpy (kj/kg) high 8 shows that the expander recovers the energy of Figure 8. Principle of expander-compressor expansion, which was historically used only for expanding using the expansion valve. Typically, the expansion of isoenthalp is driven by using an expansion valve wherein refrigerant cooled by a gas air conditioner expands from the high to low pressure. However, using an expander can lead to recovery of power produced in the process of expansion. When the recovered power is utilized as compression energy, the power consumption of the refrigerant cycle is reduced. Figure 9 shows how the efficiency of CO2 water heat systems is improved by expander-compressor coupling. Comparing the existing cycle with the expander's recovery of power, the figure also shows that recovery of energy loss due to restriction during decompression process is improved. Figure 10 shows the schematic drawing and the actual appearance of the hermetically sealed expander-compressor unit. Daikin developed this prototype for a CO2 water heater where the expander is connected with the compressor in one line, and conducted testing. The results showed that energy requirements for the compressor were reduced. The engineering development work for this CO2 water heater, expected to be complete in March 2008, has been carried out by Daikin Pressure (MPa) Expansion valve Energy loss by restrictor Former Type Gas air conditioner M Evaporator Energy recovery Power recovery New Type Gas air conditioner Figure 9. Outline of improvement of efficiency by expander compressor M Evaporator Inlet Mechanism Discharge DC Motor Outlet Suction Mechanism (a) Cross Section (b) Outlook Figure 10. Structure of hermetic prototype of - Unit

together with NEDO since June 2005. Work has focused on downsizing the water heater for the purpose of expanding its use in high density urban areas, and on improving system efficiency. However, as there are still cost barriers, more advanced development of this system is needed for market-oriented commercialization. 6. Conclusion The development of heat pump water heaters using CO2 natural refrigerant can be summarized as follows: - CO2 is suitable for home water heaters because it excels in environmental performance and can heat water to temperatures up to 90 without a heater. - For domestic use, both the user and the electric power company can benefit from operation of a CO2 heat pump unit at night. The user can reduce the operating cost and the power company can equalize electric power load. - In Japan, commercialization of residential water heaters using CO2 refrigerant began in 2001. - Thanks to development of water heat exchangers, expander-compressors, and other key components and improvement of system technologies, heat pumps may contribute significantly in future to addressing the challenge of global warming. Acknowledgement I'd like to express many thanks to the staff of Central Research Institute of Electric Power Industry, the Federation of Electric Power Companies of Japan, Tokyo Electric Power Company, Kansai Electric Power Co Inc, Chubu Electric Power, Kyushu Electric Power Company, and NEDO, New Energy and Industrial Technology Development Organization who have provided me with materials in preparing this paper. References 1) Katsumi HASHIMOTO, et al.: Trend report of development of residential CO2 heat pump hot water heater in Japan. Lectures at the 9th Power and Energy Technology Symposium (2004) 2) Hirosi NAKAYAMA, et al.: The development of heat pump water heater system with a carbon dioxide hermetic swing rotary compressor, the 9th Power and Energy Technology Symposium (2004) 3) Hirofumi IDA: The development trend and future view of the CO2 refrigerant heat pump water heater, Reito, September 2007, vol. 82, No. 959. 4) Mitsuharu NUMATA, et al.: Heat transfer enhancement of water- CO2 heat exchanger for CO2 heat-pump water heaters, JSRAE (2006). 5) Katsumi SAKITANI, et al.: Development of two-phase flow expander for CO2 air-conditioners, 8th IEA Heat Pump Conference 2005. Contact: shigeharu.taira@daikin.co.jp