E-gas Instant Gas Water Heaters



Similar documents
Gas Instantaneous Water Heater

Morco House Riverview Road Beverley HU17 0LD

User's Instructions. Alpha HE CB25/33 and HE SY25

For installation guide see reverse of book

USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

This section gives you some helpful information and tips on running your home and the equipment in it.

Thermo Siphon Solar Systems

Report. Water Efficiency Labelling for Instantaneous Gas Water Heaters. Aleksander Szann Access Product Information Consultants

Session 2: Hot Water Supply

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Endless Hot Water 24/7

Troubleshoot resources for homeowner

HEAVY DUTY STORAGE GAS

Owner s Guide and Installation Instructions

DEALING WITH PLUMBING AND HEATING EMERGENCIES

UNDERSTANDING CENTRAL HEATING SYSTEMS

Owner s Guide and Installation Instructions Continuous Flow Gas Water Heater CG26 series

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES

Owner s Guide and Installation Instructions

How to use your Water Heater

Water Heater MkII WH1302 / WH1302B INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

Itho Products for Hot and Boiling water. product-

BoilerMate SP. benchmark. user instructions A - C L A S S

Owner s Guide and Installation Instructions

Safe Method: Gas Safety in Catering Establishments

Draining and filling cooling system

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

Home comfort: water heating

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

Continuous Flow Water Heaters

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Gas geyser versus electric

Plumbing Identification and Damage Assessment Guide

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Owner s Guide and Installation Instructions Continuous Flow Gas Water Heater 884, 886 series 024 models

Response: The combi boiler. Response: The fit anywhere combi

Hot Water South Australia

Please keep this manual for f uture reference.

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

Design Utility Lever Thermostatic Bath Shower Mixer

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

Fossil fuel heating equipment

CHAPTER 9: WATER HEATING

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

HeatSource HS1800 Heater

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60

Instantaneous gas water heater

SERVICE INSTRUCTIONS


Water Heaters. Condensing Storage. In my 30-plus years as a plumbing contractor,

Hot Water Heating: Technologies and Use

Factory owners must ensure the boiler is:

Electric & Gas Water Heaters

Gas water heaters. Why Vaillant? Because warm water is our business for more than 135 years.

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

Operation / Installation Manual

2010 Residential Water Heater Replacement Check List

Owner s Manual. & Installation guide. Installation Details Owner s Information Warranty. 4 Star Gas Hot Water Heater

Baxi Combi 80e & 105e

orlando OWNER S MANUAL

Assembly and instructions

EcoSoft Water Softener. General Installation Guide

Operators manual Basic water heater

SL280UHV SERIES GAS FURNACE WARNING

A Practical Guide to Free Energy Devices

Congratulations! You've just purchased a new Marey Power Gas tankless water heater and will soon begin to enjoy the benefits of going tankless.

Gas and Oil Fired Space Heating

NAVIEN AMERICA INC FITCH AVENUE

Energy Efficiency HOSPITALITY.

Artisan Thermostatic Bath Shower Mixer

Commercial Gas Water Heaters

WC flushing cistern single or dual flush to fill in 2 minutes WC trough cistern 0.15 per WC Wash basin tap size 1 2

Water Heating and Heat Recovery 1


Vaillant s plain English guide to. simple, concise and precise

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners

1 DESCRIPTION OF THE APPLIANCE


One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Solar Hot Water. What systems are available?

Gas Water Heater. Coming into Its Own, Finally COMPARATIVE TEST

NFPA31FuelOilPiping 1 Revised

your water pressure explained

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L

Gas Water Heaters. Installation and Owner Manual MODELS LCN20/LCL20, LCN26/LCL26 - FOR EXTERNAL INSTALLATION ONLY

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

Commercial Gas Water Heaters

Commercial Gas Water Heater

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

CARING FOR YOUR WATER HEATER

A COMPARISON OF WATER LEAK DETECTION AND SHUTOFF SYSTEMS

Tankless Water Heater

Thermostatic bar showers. Troubleshooting and maintenance

Transcription:

The Proven Preferred Choice! E-gas Instant Gas Water Heaters Training & Information Manual: There are important functional and operational differences between the conventional hot water geyser and the E-gas Instant Gas Water Heater. The conventional geyser has a pressurised holding tank with a static electric heating element fitted inside. The thermostat monitors that the temperature of the water inside the tank and switches the element on / off as required in order to maintain the set hot water temperature, between 55 and 65 deg C. As hot water is drawn from the tank, fresh cooler water replaces it inside the tank. It will take up to several hours to reheat the water to the set point temperature. Modern taps are designed to operate under high water pressure conditions. They can cause problems when operated under low water pressure conditions like with the instantaneous gas water heaters. The E-gas instant gas water heaters operate through a heat exchanger. The water passes through this heat exchanger and is heated by means of a bank of burners. The E-gas system has a high quality, heavier duty heat exchanger and more burners to provide longer performance and life span as well as greater efficiency, if one compares it to some of the other products on the market. The temperature of the hot water emitting from the E-gas unit is determined by a number of factors, including the temperature of the incoming water. The setting on your system will be the setting by which the system determines how much hotter to heat the incoming water than its ambient temperature. Provided there is enough gas and incoming water, you will always have hot water, whereas with the conventional geyser hot water supply is determined by the amount of hot water in the tank system. As fresh water enters the tank of the conventional geyser, it reduces the temperature in the tank. It takes some time for the water to reach its set point temperature. The instant gas water heater operates with a delicate balance of LPG gas and water pressures. The E-gas incorporates a number of safety devices. Incorrect installation will cause one or more of these devices to shut down. It is vital that the E-gas system is installed by a registered installer, licensed with the Liquid Petroleum Gas Safety Association of South Africa. Call outs to rectify incorrect installations will be charged for, and will not be entertained as a guarantee or a warranty claim. Water Supply & Water Pressure The E-gas instant water heater is constructed to work on low pressure (0.25 Bar 5 Bar), with a minimum of a 15mm water supply. Do not reduce the diameter of the water supply feed to 12, or 10mm as with the flexible hose connectors. This will impact on the performance of the unit. The system will operate best with a 22mm water feed, reduced to 15mm half a meter from the system. This will minimise the pressure reducing effect of another cold water tap simultaneously being opened on the same feed line.

Impurities in the water are trapped by the inlet sieve before they enter the water heater. If this sieve is partially blocked this will affect the water pressure, and possibly not be enough pressure to activate the igniter. The slower flow water will become very hot. The bleed-in of incoming water through a mixer tap will put back pressure on the water heater, reducing the pressure and the system will shut down. It is sometimes advisable to fit an in-line water filter to block impurities. The E-gas instant users are low pressure appliances and do not operate best with high pressure equipment. The modern taps, and single lever taps have a 10mm diameter feed into the mixing chamber. The back pressure will adversely affect the operation of the low pressure E-gas unit. Single lever taps do not have a separate hot water shut off which when shutting the hot water supply will cause a run-on of gas burning with a reduced speed of water flow for 15 seconds increasing the temperature of the water in the heat exchanger above the preset safety level. The sensor cut out switch will shut the appliance down until the temperature has dropped to an acceptable level. In a new installation including a instant gas geyser, if the 15mm mixer units are not available, it is possible to make up 15mm mixer units by using stopcocks and attractive bath or basin spouts. The E-Gas water heater has a built in protection against water pressure surges during operation. Gas Supply and Pressure The E-gas instant water heaters operate with low pressure LPG only. Only SABS approved low pressure gas regulators must be used. The label on the unit indicates the rate of LPG consumption which the gas heater uses during operation. This is expressed in Kg/Hr. The regulator must be rated to deliver at least the same quantity of gas per hour. The gas bottle rated delivery is also important to consider during the installation. The registered installer will advise on the best combination of regulator and gas bottle applicable to the specific installation to optimise gas consumption and safe operation. How the E-gas Water Heater Works The opening of a hot water tap allows cold water to flow into the water heater. The water flowing through a valve creates pressure on a diaphragm that closes a limit switch. This in turn allows 3 volts of electricity to activate the electronic control panel, which operates the solenoid valve which releases gas to the burners as well as ignites the gas in the burners. The water passing through the heat exchanger is heated and hot water flows from the water heater. Liquid Petroleum Gas LPG is a scientific blend of propane and butane. Correct draw-off causes the blend to vaporize correctly and results in the efficient use of gas. Demand of this gas in excess of the rated amount for the bottle or regulator results in freezing of the less volatile component. Unbalanced draw-off results in gas being left in the bottle which will not vaporize and remains behind in the bottle. The gas connection from the supply bottle to the water heater must ONLY be effected with an SABS approved flexible gas hose. Distances greater than 2m, a copper pipe of at least 15mm must be used. Do not use flexible hoses to pass through the wall. The water heater makes use of a solenoid valve to allow the gas to flow into the system.

Ignition There is no pilot light. Ignition is achieved through an impulse igniter, powered by two torch batteries. The 3 volts of DC power is used for ignition, as well as it powers the solenoid valves while the system is in operation. Water Heater Controls The control on the left is marked GAS. This controls the amount of gas to the burners, which increases or reduces the size of the flame to the burners. The control on the right marked WATER controls the amount of water flowing through the heat exchanger. The greater the water flow, the cooler the water exiting the water heater will be. Slower water flow will allow the water to heat up to higher temperatures. Turning the knob to the right reduces the water flow and water flow pressure. Remember there is a certain amount of pressure required in order to keep the gas solenoid open. If the water heater is not wanting to ignite, but ignites when the control is turned fully to the right, this indicates a water pressure problem and is often a result of a dirty inlet sieve on the cold water supply. The central control knob is a gas control. The water heater is fitted with three banks of burners. The main burners are situated in the middle below the heat exchanger. On either side there are two banks of auxiliary burners. When the WINTER setting is selected, all three banks of burners come into action. Setting Your Controls To achieve the maximum heat and maximum water pressure set the GAS control to maximum, the central control to WINTER, and the WATER control to the middle. Run the water heater until a constant flow of water comes from the system. Adjust the WATER control until the water temperature is ideal for a shower via the shower mixer. PLEASE NOTE: by setting the WATER control to maximum, one reduces the hot water pressure and therefore by blending the cold water supply to achieve an acceptable temperature, you can place a back pressure on the hot water supply and cut out the water heater. If the ambient temperature of the incoming water rises this can result in an unacceptably high water temperature, simply switch the winter / summer setting to summer. This will not affect the water pressure coming out of the water heater. If the ambient temperature of the incoming water drops resulting in water which is not hot enough, you can simply adjust the hot water tap slightly by reducing the water flow through the system and increasing the temperature. It is not necessary to adjust the water heater settings. Safety Features and Devices FLUE SENSOR It is very important that burnt gasses are vented out of and away from the building by means of proper ventilation. The E-gas monitors this function by measuring the temperature of the gasses in the exit flue. If the temperature in the flue gets too high, this means that the gasses are not escaping. This could result in dangerous gasses spilling into the room. The cut out sensor will shut the system down if the temperature gets too high.

The installation of a secondary flue pipe to remove the combusted product to outside the building is essential. WATER TEMPERATURE SENSOR This sensor is situated on the hot water outlet of the heat exchanger and will shut down if the temperature gets above a certain temperature (normally 75 Deg C) FLAME OUT DEVICE This is a sensor on the bank of burners, which if the flame is extinguished, it shuts off the gas supply. If there is not enough water pressure to activate the igniters, no gas will be released into the system. FREEZING CLIMATES The E-gas water heater has a drain plug which can be opened to empty the heat exchanger of water when freezing weather is expected to prevent the bursting of internal pipes. WHAT SIZE WATER HEATER SHOULD I SELLECT The size of water heater is expressed in terms of its nominal capacity of delivery of hot water in Litres/ Minute - 6 Litre: mostly suitable for smaller kitchen type installations, wash basin etc - 8 Litre: same as above, can fill a bath slowly - 12 Litre: 2 bathrooms & kitchen - 16 Litre: 2 bathrooms & kitchen When deciding on the size of the unit, one needs to consider points like number of hot water outlets used simultaneously, and how often. Sometimes it is more economical to have two smaller units, than on larger unit. TEST DRILL TO CHECK HEATER FUNCTIONALITY Remove the cover Open to hot water outlet Water flows through the unit, but the unit does not operate and there is no electrical spark Using an electrical tester check that there is electrical current at the battery box outlet and that the polarity of the batteries is correct Replace the batteries if necessary If there is still no spark, bridge the flue sensor with a piece of electrical flex with a crocodile clip at each end. The unit operates problem solved replace the flue sensor The unit does not operate Repeat step with the crocodile clip The unit operates problem solved replace the hot water sensor The unit still does not operate replace the hot water unit if under one year old and the guarantee has not been invalidated.

at the third step above: OR The water flows through the unit, the impulse igniter works and there is a visible spark from the igniters above the burners, then the problem is confined to the gas system, then.. Replace the gas solenoid The unit works the problem solved The unit does not operate replace the electronic control box The unit still does not operate follow the last step in the section above. E-gas Instant Water Heaters have been fully tested and certified by an Approved Laboratory as being fully compliant with the provisions of the SABS Regulation 1539. The relevant permit has been issued by the LPGSA Safety Association.