DIVISION 28 ELECTRONIC SAFETY AND SECURITY



Similar documents
DIVISION 28 ELECTRONIC SAFETY AND SECURITY

CONSULTANT PROCEDURES & DESIGN GUIDELINES ACCESS CONTROL SYSTEM

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION SECURITY SYSTEMS

Middleborough Police Electronic Security Narrative

UBC Technical Guidelines Section Edition Secure Access: General Standards Page 1 of 7

SECTION ELECTRO-MECHANICAL HARDWARE

A. Provide a complete and fully operation Access Control system fully integrated to the campus Lenel system.

Your Canadian Security Specialists. Eddie D Orazio

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

SECTION DETECTION AND ALARM

Doc 10. UTM Standards: Card Access Security System

IMS [Integrated Management System] Surveillance Solution Segment Focus: Gaming Industry

Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

We suppy surveillance equipment, wireless security systems, CCTV surveillance camera, access control security systems, service provider of system

>>IP. VIDEO INTERCOM & SMART HOME TCP/IP video intercom solution expert

NeuStar Ultra Services Physical Security Overview

AX.S Series Access Control and I.AM Series Identity Access Management

Alert Technology Group 46 Empey St, Brantford ON Office Toll Free

GSM ALARM SYSTEM USER MANUAL

PART A. Option 1: City Hall & POA Supply and Install Lenel Onguard Security Upgrade and supply and Install Axis IP Cameras

IP Camera Tutorial. What is a Network Camera?

Security System Proposal. Rich Destremps

CalMod Design-Build Electrification Services

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

EQUIPMENT SPECIFICATIONS

Access Professional Edition Selection Guide

Security Management System

Current as of 11/10/08 1 of 1

GLOSSARY of SECURITY TERMS

GMS GRAPHICAL MANAGEMENT SYSTEM

GT Series. Multi-Tenant Security Intercom. Architectural and Engineering Specifications

PLAN REVIEW GUIDE FOR FIRE ALARM

BUILDING SECURITY & ACCESS CONTROL

WaterCress - Critical Infrastructure Protection

CCTV GUIDE: Guide to Surveillance Camera Systems. CCTV GUIDE: Guide to Surveillance Camera Systems

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

Architectural. Access Control System - CAAMS

Concierge. Outdoor panels

TECHNICAL QUESTIONS AND ANSWERS ITN-DOT-14/ RM TAMPA OPERATIONS CENTER VIDEO SURVEILLANCE/SECURITY ACCESS SYSTEM

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

SECTION ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.

Data Center Presentation

Comprehensive Security with one Powerful System. G Series integrated security, fire and access control panels

Hortonville School District Door Control System Phase I Request for Proposal July 5th, 2013

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

1. The objective of this guideline is to provide minimum standards for design and installation of fire alarm systems for the University of Missouri.

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

AUDIO VIDEO INTERCOM SYSTEMS SECURITY & SAFETY AT YOUR FINGER TIPS AUDIO VIDEO INTERCOM SYSTEMS

Functional Specification Document

Panasonic Video Surveillance Solutions One Partner. One Solution.

University of Nevada, Reno. UNR Building Access Cards and Key Control Procedures 1

Business Owner s. Security Buyers. Guide. Everything you need to know before purchasing a security system. Safer. Smarter. Tyco.

Axcys Wireless Alarm and Monitoring System Self Storage Units - Containers - Gate - Man Door

Security Systems Intrusion Alarm

Pioneering Industry Leader Integration

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

ACCESS CONTROL MANY FUNCTIONS. ONE SYSTEM. ONE CARD.

Security System Proposal

38. ACCESS CONTROL AND ELECTRONIC SECURITY SYSTEM

For Small Business. Cisco IP Video Sur veillance Solutions

Honeywell s WIN PAK SE 2.0 / WIN PAK PE 2.0 Access Control System Guide Specifications in CSI Format SECTION

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

Smile Security and Surveillance Pvt. Ltd. (SSSPL) Brings to you

Alarm Systems. Peace of Mind. Agri-Alert alarms have been protecting swine operations across the world since automated production systems

IP Video Surveillance

EKON BMS HVAC system. Simply Smart. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch

Complete solutions for commercial security. Verex delivers leading intrusion, access and video products to protect today s companies

City of Riverside Building & Safety Division Phone: (951)

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Cisco IP Video Sur veillance Solutions

Electrical. This section applies to the design and installation of building power distribution systems.

ACCESS CONTROL SYSTEM

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SYMMETRY PRODUCT OVERVIEW

Reliable Security Solutions

Integrated Building Management and Security System. Building Automation & Security.

SYMMETRY. DATASHEET ACCESS CONTROL Product Overview

Office of Integrated Security Systems Longwood University Camera System Standards

Access control designed simply for you

QUALITY SERVICES LEADING TO QUALITY BUSINESS

VERTICAL SOLUTION GUIDE

Using your LED Plus keypad

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

Integration of Alarm Systems

Product Guide Specification

Surveillance and Security for Casinos. Cost-Effective Solutions for Any Size Facility

Transcription:

DIVISION 28 ELECTRONIC SAFETY AND SECURITY CENTRALLY MANAGED ELECTRONIC ACCESS CONTROL, VIDEO SURVEILLANCE, AND INTRUSION ALARM SYSTEMS 1. All questions on equipment approvals in this section shall be forwarded to the Department of Central Security, 2221 University Avenue S.E.., Suite 335 UOP, Minneapolis, MN 55414 (612) 624-1750. 2. Requirements in this section apply to all new construction, as well as remodeling projects with estimated construction costs in excess of $100,000 and/or projects that effect building access. 3. The Department of Central Security will conduct a security assessment during the Schematic Design phase. 3.1. The purpose of the security assessment shall be to apply University of Minnesota security design criteria and: A. Determine whether or not an electronic access control system shall be incorporated into the scope of the project B. Determine whether or not a video surveillance system shall be incorporated into the scope of the project C. Determine whether or not an electronic intrusion alarm system shall be incorporated into the scope of the project 3.2. The security assessment shall be done without cost to the project and Utilize the following security design criteria matrix.

Design Levels and Required Applications Maroon Gold Platinum Emergency Communication Systems * Building Interior - Intercom System/Call Boxes * Building Exterior - CODE BLUE Alarm Systems Alarm Systems * Building Exterior/Interior - PHOENIX * Building Exterior/Interior - PHOENIX * Grounds Sensor System - PERMITRAX Video Surveillance Systems Video Surveillance Systems Video Surveillance Systems * Building Access Points - INTELLEX Digital * Building Access Points - INTELLEX Digital * Building Access Points - INTELLEX Digital * Building Interior Spaces - INTELLEX Digital * Building Interior Spaces - INTELLEX Digital * Target Specific - MOTION SENSING/VIDEO ANALYTICS Electronic Access Control Systems Electronic Access Control Systems Electronic Access Control Systems * Building Exterior - CCURE Standard * Building Exterior - CCURE Standard * Building Exterior - CCURE Standard * Building Interior - CCURE Standard * Building Interior - CCURE Standard * Building Interior - CCURE Wireless * Building Interior - CCURE Wireless * Building Interior - Locknetics Standalone * Building Interior - Locknetics Standalone * Building Inetrior - Smart Card * Building Interior - Biometrics Security Keying Systems Security Keying Systems Security Keying Systems * Building Exterior - KEYMARK * Building Exterior - KEYMARK * Building Exterior - KEYMARK * Building Interior - BEST Standard * Building Interior - BEST Standard or KEYMARK * Building Interior - BEST Standard, KEYMARK, or MEDECO M3 * Building Interior - KEYTRAK Key Safe * Building Interior - KEYTRAK Key Safe * Building Interior - KEYTRAK Key Safe Building Entrances Administrative Offices Housing and Residential Life General Purpose Offices Business Offices High Risk Research Laboratories Low Risk Research Laboratories High Value Supply/Equipment Storage Areas Computer Laboratories General Purpose Classrooms Technology Enhanced Classrooms Pharmacies Low Risk Supply/Equipment Storage Areas Targeted Facility Elevators Controlled Substance Laboratories General Purpose Elevators Targeted Facility Corridors Cash Handling Areas General Purpose Corridors Links, Tunnels, and Skyways Special Event Venues Loading Docks Parking Lots, Ramps, and Garages Federal Government Facilities Executive Offices and Residences Funded within the Project Unfunded

Electronic Access Control Systems 4. Incorporate a minimum of two exterior doors with hard-wired card access and a controlled for all new buildings. 5. Rekeying of all exterior doors is required upon completion of installation and testing. Three emergency bypass keys shall be created and distributed as follows to 1. Building Manager, 2. Fire Department Lock Box, and 3. Building Systems Automation Center. 6. All card reader control panels shall have a minimum 12-hour (design calculations required) battery backup, and battery standby power supplies to maintain database programming and card reader operation. Electric locking devices on perimeter doors with electric strikes operated by card readers shall have battery standby power supplies if determined by a security assessment. 7. The University of Minnesota s Access Control System operates on a Software House C-Cure 8000 platform. All card readers on perimeter doors, perimeter door access control systems, and door monitoring systems shall interface with this system. The aforementioned security assessment will determine if other card readers or door access control systems such as biometric devices shall be required. 8. Use conduit and raceways on system installation. They shall comply with conduit and raceway standards specified in Section 260533 Raceway and Boxes for Electrical Systems, and the manufacturer's requirements of the access control systems. 9. System installation shall use wire and cable that complies with wire and cable standards specified in Section 260519 Low Voltage Power Conductors and Cables, and the manufacturer's requirements of the access control systems. 10. Refer to Division 8, Section 087000 - Hardware for system hardware requirements. 11. Access control systems shall have the following components/capabilities: 11.1 Magnetic Stripe Cards: When specified by Central Security, access control systems must be able to read and reference university-manufactured, encoded and issued University of Minnesota U Cards adhering to ISO standards 7811/2 and 7811/4. 11.2 Magnetic Stripe Card Readers: Card readers shall be Sensormatic (Software House) RM1-MP Magnetic Stripe Readers. 11.3 iclass Smart Cards: When specified by Central Security, access control systems must be able to read and reference university-manufactured, encoded and issued University of Minnesota U Cards containing iclass smart card technology.

11.4 iclass Card Readers: Card readers shall be Sensormatic (Software House) RM1-1C iclass Smart Card readers. 11.5 Biometric Identification may be required for Government Compliance and/or by Regulatory Agency Requirements. 11.6 Biometric Readers: Hand Geometry readers shall be IR Recognition Systems HANDKEY II devices. 12. Exterior card readers shall have a manufactured heater kit. 13. Nominal Card Reader Mounting Height: Card readers shall be mounted at the following heights: A. Interior: 42 inches to center above the finished floor B. Exterior: 36 inches to center above the finished floor C. Elevators: 36 inches to center above the finished floor D. Bollard Mount: 36 inches to center above the walkway. 14. A door position switch is required on all door installations. The exit motion detector shall not be used to unlock the doors.. 15. A request exit motion detector is required on all door installations. 16. Card Reader Control Panels: Card reader controllers shall be either Software House istar controllers or apc/8x advanced processing controllers as determined by the Department of Central Security assessment. Under certain conditions apc LITE controllers will be specified for remote site installations. No substitutions are permitted. istar and apc controllers shall support a minimum of eight card reader interface options. Card reader controllers shall have the following components/capabilities: 16.1. istar Controllers: 16.1.1. Support eight card readers with independent addresses. 16.1.2 The istar Controller will be connected with the University Access Control Management System via VLAN6 ether jack connection. The Office of Information Technology shall install the connection at least two weeks prior to being required. Locate the jack inside the istar Controller. 16.2. apc Controllers: 16.2.1. Support eight card readers in a star configuration with independent addresses.

16.2.2. A star coupler module that is capable of supporting eight independent card readers, eight unsupervised inputs and eight additional relay outputs. 16.2.3 A mini star coupler module is acceptable if the eight unsupervised inputs and the additional eight-relay output capacity are not required. 16.2.4 The apc will be connected with the University Access Control Management System via VLAN6 ether jack connection. The Office of Information Technology shall install the connection at least two weeks prior to being required. Locate the jack and the LANtronic serial server inside the apc panel. 16.3. Card Reader Controller Standby Power: The standby power systems for card reader controllers shall be Alarm-Saf AS/PS5-BFS-12-UL. The power systems shall have 4 hours of battery backup. 17. Electric Lock Power Supply: Electric lock power supply shall be Alarm-Saf AS/PS5-BFS-24-UL. This shall include electric door strikes, electric door control and exit devices on perimeter doors or interior doors determined to require power supply by the aforementioned university security audit. Electric lock power supply shall have the following components/capabilities: A. Four (4) hours of battery backup for all perimeter doors B. Support all perimeter electric door control and exit device functions for a minimum of four (4) hours. 18. Elevator Control: Elevator control shall be managed from the University Card Access Management System with the following components/capabilities: A. One apc per elevator that services four or more floors B. Cable and wire that connects the card reader to the apc and the apc to the elevator controller, if elevator controller is required. Refer to Division 14, Section 142000 Elevators. Video Surveillance Systems

10. Video Surveillance shall be incorporated into the design of all building access points (above and below grade) within new construction projects. 10.1 Video surveillance installations shall be centrally monitored and recorded by the Department of Central Security in accordance with University archive and retrieval policy. 10.1.1 When special circumstances create the need for specific business use of video surveillance, a stand alone installation may be used. Such installations require a written exemption from the Director of the Department of Central Security and written acceptance of liability by the Director of the customer unit. 10.2. Video surveillance systems shall have the following components and capabilities: 10.2.1. Video surveillance systems shall include digital recording, multiplexing and Internet-based server capabilities. 10.2.2. Exterior cameras shall be both environmentally protected and heated. Provisions for preventing snow and ice build-up shall be included. Daytime and nighttime cameras that are equipped with an electronic auto iris are required for all exterior applications. 10.2.3. Interior cameras shall be premium grade and provide high resolution color images. Applications that have variable lighting conditions shall require an auto iris lens on each interior camera. 10.2.4. Acceptable equipment shall include: American Dynamics Intellex Platform. Digital Video Recorders shall be American Dynamics Intellex DVMS, Intellex Ultra, or Intellex IP as required with sufficient storage capacity to maintain 30 days of recorded video at maximum resolution. Fixed Cameras shall be Panasonic WV-CW484S with suitable housing, mount, and accessories to provide a functional camera system. Pan, Tilt, and Zoom Cameras shall be American Dynamics ADSDU835N with suitable housing, mount, and accessories to provide a functional camera system. Outdoor installations will require a Panasonic Mounting Base WV-Q114, a Panasonic Heater Unit WV-CW4H, and/or a Panasonic Embedded Ceiling Mount Bracket WV-Q166. Intrusion Alarm Systems 11. The design of electronic security systems shall be incorporated into both new

construction and renovation projects to meet a variety of personal and property security needs. Each design shall be considered unique and require that the Department of Central Security review and approve each design. 11.1. Despite each unique design, all electronic security systems shall have alarm systems with control panels that have the following components and capabilities: 11.1.1. FBI brand XL-5 model control panels shall be used for hardwire sensor systems. 11.1.2. One dedicated analog telephone line shall be required for each control panel. 11.1.3. One dedicated 120 volt AC power source with a minimum of 24-hour battery backup shall be provided for each control panel. 11.1.4. Control panels shall be programmed to communicate with the Phoenix alarm server and Phoenix monitoring software located at the University of Minnesota Police Department. Programming specifications shall be coordinated with the Technical Services unit within the Department of Central Security. Manual Security Systems 12. See Division 8 for information regarding lock cylinders, keying and key control.. End of