AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions



Similar documents
PC Tab Security System INSTRUCTION MANUAL

616, 626, 636 & 646 Keypads

INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD

HILLS Series LED Code Pad User Manual

GE Concord 4 Quick User Guide

Using your LED Plus keypad

PK5500 v1.1 Installation Instructions

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

LCD5500Z / PKP-LCD v3.x Installation Instructions

User s Information Guide R1A

ELECTRIC FENCE ENERGISER

Wireless Home Security System Product Manual (Model #80355)

EKP1 LED KEYPAD. Owner's Manual. Use with AV9000 & SC800/1600 Series Control panel

Users Guide to Keypad Functions

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

INSTRUCTION MANUAL LCD-6OO SECURITY STATION

Reference & Installation Manual

INSTALLATION MANUAL PC2525. Version 1.1

PRODUCT WARRANTY. Page 20

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Owner s Guide. ca6554

Emergency Dialer DIAL-ALERT MODEL: AD

642 LCD Keypad User Manual

NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

Control/Communicator Installation Manual

CAPTAIN 6. USER GUIDE System ver Zones Intruder Alarm System. PIMA Electronic Systems Ltd.

POWER POWER ABC DEF GHI JKL ABC DEF GHI JKL COMMAND YZ COMMAND POWER ABC DEF GHI JKL COMMAND YZ USER'S GUIDE

IDS X-Series User Manual D Issued July 2012

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Flarm LED indicator. Version 1.1

InHome Water Leak Detection Package

SECURITY SYSTEM NOTES SPECIAL CODES AUXILIARY ARM / DISARM CODES ENTRY / EXIT DELAY TIMES ZONE DESCRIPTIONS

LCD and 16-Zone LED Keypads. User s Manual

SECURITY SYSTEM NOTES SPECIAL CODES. Security System Configuration

Crow Limited Warranty. Print Version 017

728 SERIES REFERENCE & INSTALLATION MANUAL 728+ VERSION series

Advantium 2 Plus Alarm

SECTION DETECTION AND ALARM

DC-8706K Auto Dial Alarm System

HILLS Series LED Code Pad User Manual

INTRODUCTION 2 Features... 2 Specifications... 2

AC-115 Compact Networked Single Door Controller. Installation and User Manual

SECURITY SYSTEM NOTES. Security System Configuration

Using Your GEM-P400 Security System

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

10-Zone Spectra LED Keypads

GSM Gate Opener GSM Remote Switch RTU5015 User Manual

INSTRUCTION MANUAL PC255O

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

Ademco Vista-20P/First Alert FA-168C Basic Commands

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES

NetworX NX-6V2. LED Keypad User Manual


SECURITY SYSTEM NOTES AREA LISTINGS SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

NESS D Zone Control Panel and Dialler OWNER S MANUAL

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

Application Notes Partition Programming (PC1616/1832/1864 V4.2) Page 42. Panels: POWER SERIES (PC1616/1832/1864 V4.

GSM Gate Opener GSM Remote Switch RTU5015. User Manual. Ver 1.3 Date Issued: All rights reserved by King Pigeon Hi-Tech. Co., Ltd.

Automatic Phone-Out Home Monitoring Systems

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

Installation and Operation Guide PD4600 Series Converter Replacement

Alarm Clock USER GUIDE

SECURITY SYSTEM NOTES

astec Integrated Alarm System USER GUIDE

Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)

Model SRMD Setra Remote Monitoring Display

PowerWave-8. Users Operating and Programming Guide Version zone Control panel Communicator

Powerware Relay-Serial Card User s Guide

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

ACTIVE 5 ENGINEERING MANUAL

SECURITY SYSTEM NOTES

Iphone & Android App Smart GSM Home Alarm System

MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3

Installation and Operation Guide for PD4100 Series Power Control Centers

Business/Home GSM Alarm System. Installation and User Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Digiplex LCD Keypad DGP-641. User s Manual

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

Contents 1. Terms you may neeed to know 2. Keypad Lights 3, 4. Keypad Buttons 5

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

TABLE OF CONTENTS FEATURES

tattletale User Guide Consumer unit version P a g e

SECURITY SYSTEM MANUAL

We are confident you will find the PC5132-RS Wireless Receiver a unique and useful control panel enhancement.

e-ask electronic Access Security Keyless-entry Consumer Manual FCC ID: TV2EFOB1 (UM12 ~ )

ICP-CC488. Installation Guide ICP-CC488 Control Panel

Solution-16 Operators Manual ISSUE 1.60

S100. GSM House Alarm System.

Auto Dialer. Manual E-921APQ E-921GPQ

User Manual (English)

GSM Alarm System User Manual

Intelli-Time Alarm Clock model 13027

SECURITY ALARM CONTROL PANEL QUICK SETUP & USER MANUAL

AUTODIALLER / QUICKDIALLER - SA132

TAC2C & TAC2D TAC1 RETROFIT KIT FOR CROWN JEWEL & DOORKING 1812 SYSTEMS

Transcription:

AIM TECHNICAL MANUAL AIM-1450HW HARDWIRE PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING See page 9 for Activation Instructions

AIM Technical Manual - AIM 1450HW AIM-1450HW HARDWIRE ABOUT YOUR AIM NOTIFICATION SYSTEM Your AIM 1450HW is designed for use on constructions sites, boats, trailers, RV s, Cottages or anywhere the use of a traditional security system is not possible. The AIM unit is an independent system that does not require phone lines or hardwired AC Power. AIM utilizes a self-contained battery power source allowing you to place the AIM unit where it will be most effective. The special design of this unit will run for long periods of time without recharging the battery and can be installed with a solar panel giving AIM unlimited run time. Activity Notification uses the Rogers GSM cellular network, which reports data direct to your monitoring station. TESTING To ensure that your system continues to function as intended, you must test your system weekly. If your system does not function properly, call your installation company for service. MONITORING This system is capable of transmitting alarms, trouble, daily test with voltage reading, arming & disarming and emergency information over the GSM Rogers Cellular Network to a monitoring station. If you inadvertently initiate an alarm, immediately call the monitoring station to prevent an unnecessary response. GENERAL SYSTEM OPERATION Your AIM 1450HW communicates to your monitoring station by utilizing the Rogers GSM cellular network. AIM comes complete with a hardwired keypad for arming and disarming. Our unique low voltage system draws very little current allowing extended battery life or unlimited power in solar panel applications. The AIM series works in conjunction with the Visonic powercode line of peripherals, so AIM can be custom designed for your application. 2

IMPORTANT NOTICE AIM Armstrong s Intelligent Monitoring Systems A security system cannot prevent emergencies. It is only intended to alert you and if included your monitoring station of an emergency situation. Security systems are generally very reliable but they may not work under all conditions and they are not a substitute for prudent security practices of life and property insurance. Your security system should be installed and serviced by qualified security professionals who should instruct you on the level of protection that has been provided and on system operations. TABLE OF CONTENTS: AIM Hardware Overview...2 Programming/Installation...4 Power...4 Zone Programming...5 Powerside...5 Jumper Settings...5 Arming the System...6 Signals...6 2-Tone Chime...7 AIM LED Status...7 Keypad Wiring/Programming...7/8 Notification Activation...9 Warranty...10 Procedure for Warranty Claims...11 CONTACT INFORMATION: Technical support: 1-877-246-7129 or Aim@armcom.ca Billing inquiries: 1-800-986-0000 or aimadmin@armcom.ca Activation Form: Fax 1-506-339-5195 All other inquires: 1-877-246-7129 www.aimalert.com 3

AIM Technical Manual - AIM 1450HW PROGRAMING / INSTALLATION OF AIM 1450HW Your AIM system comes completely programmed. Simply install AIM by following these easy steps Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Step 9 Complete and send the enclosed ACTIVATION FORM this will ensure the radio is fully activated and programmed to your monitoring station prior to installation. Before mounting the unit it is recommended that you test the GSM radio to ensure there is coverage. Power up the system install 2-7amp AH batteries, secured with the battery straps provided Turn the system off with keypad provided, See page 7 for keypad wiring and instructions. Install solar panel or 16Vac if unit is a permanent install Install devices, see page 8 for approved list of devices Set jumper 1 to on if using zone 1 delay Set jumper 2 to on if using on board relay for a siren install Arm system and test all zones, remembering the swinger shutdown when testing on page 6 POWER REQUIREMENTS 1450HW The unit has a built in regulator for 16v A/C and D/C so the battery will not overcharge. The unit will run on battery only or with 16v A/C transformer and or solar or automobile power. Solar panel requirements: 12v 5 watt minimum, AIM voltage test are read at the solar side before regulator. Eg sunny day 16.2v or cloudy day 12.7v 4

AIM Armstrong s Intelligent Monitoring Systems ZONE PROGRAMMING FOR AIM-1450HW Z1 N/C If jumper is on J1 Zone 1 is a delay zone Z2 Z3 Z4 Z5 N/C N/C N/C N/C Z6 N/C 24 Hour zone Z7 Z8 N/O N/O POWER SIDE 12V- IN Solar or Automobile Power Input 12V+ IN Solar or Automobile Power Input BATT - BATT + COM NO UPLINK+ GRD ON/OFF BUZZ- Battery 12V INPUT Battery 12V INPUT Relay 2AMP rated Relay 2AMP rated UPLINK Power Duplicate Power PIN Used for keyswitch ON/OFF Used with GRD when closed AIM unit is off Negative side of buzzer 100MA MAX draw 12V+ LED status LED- LED status LED terminals have built in resistor, LED can be direct 16VAC 16V transformer JUMPER SETTINGS J1 ON J2 ON J3 OFF J4 Zone 1 is exit delay Will not trip relay on alarm Hardwire keypad and zone 8 is a N/O zone Not used 5

AIM Technical Manual - AIM 1450HW ARMING THE SYSTEM AIM 1450HW comes with a Visonic CL-8 keypad. System default code is 1111. To arm (on) system enter 1111 followed by the * key. Yellow LED in keypad will be steady or flashing. To disarm enter 1111 followed by the * key. Yellow LED will not be illuminated and system is now disarmed (off). SIGNALS AIM board is hard coded for the following: Daily test signal with current voltage reading Unit will not send any signals during the power up process which takes approximately 30 seconds. Once activated the unit will send an activation signal and a test signal. Exit and entry delay (if used) is preset for 45 seconds. The unit sends restores. The unit sends arming/disarming signals to station. Board has swinger shutdown programmed (3 alarms per zone per hour, then system will reset) In case of cellular signal loss the unit will stay awake for a maximum of 4 minutes trying to send data. If unable to send then the unit will shut down for 30 minutes before trying again (this cycle is repeated 5 times). If the unit is still unsuccessful to transmit a signal it will buffer the alarm and send with the next transmission. When activated the unit will awake and transmit. This typically takes less than 45 seconds to reach the monitoring station, but may take up to 2 minutes depending on the amount of data being transmitted. AIM reports in Contact ID format and includes the battery voltage in every test code. An example of the contact ID format a test code is E602128. The E602 represent the test code and the voltage is the last 3 numbers. Making the voltage reading is 12.8. The test signal reports during regular business hours. 6

2 TONE CHIME Connect 2 tone chime to buzz- and 12v+ AIM Armstrong s Intelligent Monitoring Systems Chime will sound for 1 time for unit ON, and 2 times for unit OFF Chime will sound a slow beep for 45 seconds on exit Chime will sound a fast beep for 45 seconds on entry Chime output is 30 seconds on an alarm AIM LED STATUS 1450HW LED flashing slow LED flashing fast LED solid LED off System armed System reported to monitoring station and waiting for acknowledgment System reporting System disarmed VISONIC CL-8A KEYPAD WIRING AND CODE PROGRAMMING Keypad is preprogrammed to AIM unit WIRING (keypad needs 1 jumper wire installed and 4 wires connected to board) CL-8A AIM Board Loop Contact 3 to contact 7 on CL-8A Contact 4 to LED- Contact 6 to Batt - Contact 7 to Batt + Contact 9 to AIM On/Off 7

AIM Technical Manual - AIM 1450HW PROGRAMMING KEYPAD (must turn off relay and set aux to latch on code) To enter programming mode and turn off relay and set aux to latch on code **1234**200## turns off relay **1234**32## set aux to latch on code entry TO CHANGE MASTER CODE **1234**1 (LED flashes fast) 01# (LED lights for 2 seconds then flashes fast) xxxx (new 4 digit code)# xxxx (reenter new code) # LED lights for 2 seconds then flashes fast) 2 (this is for aux relay only # (LED lights for 2 seconds then flashes slow)# For example to change master code to 5555: **1234**101#5555#5555#2## Keypad LED status green on when in programming mode Yellow = status of unit Red= not used APPROVED PERIPHERALS Keypad Visonic CL-8, CL-80 Outside Keypad Motion Detector 9v SRN 2000 Any Dry Contact 15 watt siren Smoke Detector 2012HA SYSTEM SENSOR Glassbreak GE 5150-W Temperature Sensor GRI T8050 Thermal Temp Sensor by GRISK 8

AIM Armstrong s Intelligent Monitoring Systems CONNECTING UNIT TO AIM S NOTIFICATION CENTRE: Please follow the steps listed below: 1. Connecting Unit to AIM s Notification Centre: 1. In order to activate the unit to the notification centre the enclosed Activation Form MUST be faxed to 1-506-339-5195 or emailed to aim@armcom.ca 2. Once the Activation Form is received for processing testing can begin within 24 hours of activation. 4. To test the notification process, turn system on and verify with your monitoring station that the signal was received 5. If you do not receive the initial activation signal within 5 minutes call your monitoring centre to start the trouble shooting process. If the notification center has not received this signal this indicates poor or no GSM cell coverage in the area you have located the AIM product. Therefore the AIM product must be relocated to a position/area with GSM cell coverage. (Hint: try placing the AIM in a higher location for better coverage or an external high gain antenna maybe required). 9

AIM Technical Manual - AIM 1450HW LIMITED WARRANTY All Armstrong s Intelligent Monitoring Ltd. (AIM) products are warranted to be free from defects in materials or workmanship for one year from the date of purchase. Within this period, AIM. will, at its sole option, repair or replace any components which fail in normal use. Such repairs or replacement will be made at no charge to the customer for parts or labor, provided that the customer shall be responsible for any transportation cost. This warranty does not cover failures due to abuse, misuse, accident or unauthorized alterations or repairs. THE WARRANTIES AND REMEDIES CONTAINED HEREIN ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING ANY LIABILITY ARISING UNDER ANY WARRANTY OF MERCHANTABILITY OR FIT- NESS FOR A PARTICULAR PURPOSE, STATUTORY OR OTHER- WISE. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, WHICH MAY VARY FROM STATE/PROVINCE TO STATE/PROVINCE. IN NO EVENT SHALL ARMSTRONG S INTELLIGENT MONITORING BE LIABLE FOR ANY INCIDENTAL, SPECIAL, INDIRECT OR CONSE- QUENTIAL DAMAGES, WHETHER RESULTING FROM THE USE, MISUSE OR INABILITY TO USE THE PRODUCT OR FROM DEFECTS IN THE PRODUCT. SOME STATES DO NOT ALLOW THE EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU. AIM retains the exclusive right to repair or replace the product or offer a full refund of the purchase price at its sole discretion. SUCH REMEDY SHALL BE YOUR SOLE AND EXCLUSIVE REMEDY FOR ANY BREACH OF WARRANTY. See page 11 for Procedure for Claims Under Limited Warranties 10

AIM Armstrong s Intelligent Monitoring Systems Procedure for Claims Under Limited Warranties To obtain warranty service, an original or copy of the sales receipt from the original retailer is required. Online auction confirmations are not accepted for warranty verification, and AIM will not replace missing components from any package purchased through an online auction. AIM retains the exclusive right to either repair or replace the unit with a "newly-overhauled" (NOH) unit or new unit at its sole discretion. The same policy shall apply to software. Please complete these two easy steps: STEP 1: Contact AIM Technical Support to receive an RMA number. E-mail AIM Technical Support Specialists to describe the problem you are experiencing and request a Return Material Authorization (RMA) tracking number. In addition to your original sales receipt, you will need to provide the unit's serial number (if available), your return shipping address, and a daytime telephone number. E-mail: aim@armcom.ca STEP 2: Ship the unit, along with the RMA number, to Armstrong s Intelligent Monitoring Ltd. Once you have received the RMA number, securely package the unit and ship it (insured) to the following address: Armstrong s Intelligent Monitoring Ltd. 380 Salmon River Mouth Road. RMA Number: (insert your RMA number here - see above) Coal Creek, NB, Canada E4A 2T7 11

TOLL FREE: 1-877-AIM-7129 PHONE: (506) 339-1083 New Brunswick - Head Office 380 Salmon River Mouth Road Coal Creek, NB, Canada E4A 2T7 CONTACT INFORMATION: Technical support: 1-877-246-7129 or aim@armcom.ca Billing inquiries: 1-800-986-0000 or aimadmin@armcom.ca Activation Form: aim@armcom.ca: or fax 1-506-339-5195 All other inquires: 1-877-246-7129 www.aimalert.com 12 PATENT PENDING