s in Effect by Mandated or Electrical Mechanical Plumbing Fuel Gas Efficiency Accessibility Life Safety Fire Alabama (AL) The only state mandatory code is Life Safety. Only state buildings, schools, hotels, and movie theaters are mandated for the remaining codes Base Alabama (Chapter 34) Electrical Mechanical Plumbing Fuel Gas 2010 ADA Accessibility Fire Fire Alaska (AK) Arizona (AZ) STATE MANDATED, except for 1, 2, or 3 family dwellings, and energy efficiency, as indicated Arizona is a Home-Rule state, in which codes are adopted and enforced at a local level. Fire is used if municipality has not adopted own code Base for Manufactured Mobile homes (Chapter 34) Alaska, Title 8, Ch. 70 Electrical Mechanical Alaska Title 8, Ch. 63 Plumbing Alaska Title 8, Ch. 63 Fuel Gas Alaska Building Efficiency Standards APPROVED CODE (IECC), ASHRAE 62.2 2010 (and Alaska Specific to both) 2010 ADA Accessibility Alaska Title 13 ch 50-55 Fire Base Fire Arizona Fire Title 41 ch. 16 Fire 2012 Arkansas 2012 Arkansas 2012 Arkansas Arkansas National Electrical Arkansas Mechanical 2006 Arkansas Plumbing 2006 Arkansas Fuel Gas 2011 Arkansas 2012 Arkansas 2012 Arkansas Arkansas (AR) Mandated by Fire 01/01/2014 Base vol. 2 amendments Vol. 3 Electric Cide Mechanical Plumbing Fuel Gas except ch 5 2009 IECC ICC/ANSI Fire Vol. 1 Fire Vol. 1 California (CA) Mandated Base 2012 2010 California Electrical Electrical Mechanical 2012 Uniform Mechanical Plumbing 2012 Uniform Plumbing, Title 24, Part 6, Title 24, Part 2 Fire Fire Fire Fire Page 1 of 11
s in Effect by Mandated or Electrical Mechanical Plumbing Fuel Gas Efficiency Accessibility Life Safety Fire Colorado (CO), s adopted at local levels unless the building is a state building or a public school Base Electrical Mechanical Plumbing Fuel Gas 2003 ICC/ANSI 2006 NFPA 1 2006 NFPA 101 (CT) Mandated, now looking to adopt new in 2015 Base 2005 Building (2005 ; 2009 2005 Building (2005 ; 2009 2013 amendment 2005 Building (2005 ; 2009 2005 Building (2005 ; 2009 Electrical NFPA 70-2011 2013 amendment 2005 Building (2005 ; 2009 Mechanical 2005 Building (2005 ; 2009 Plumbing CT state reg 29-329 29-330 29-331 1995 NFPA 54 2009 (2011 2005 Building (2005 ; 2009 ICC/ANSI - 2003 Fire - 2003 NFPA 101 Fire - 2003 NFPA 101 with 2009 Delaware (DE) Building codes are adopted by the counties in Delaware, only some codes are Mandated, as listed Base Fire Prevention Regulation Electrical Mechanical Plumbing Fire Prevention Fuel Gas Fire Prevention - Delaware Architectural Accessibility Standards Fire Prevention Fire Prevention ANSI NFPA 101 12A DCMR 12B DCMR 12J DCMR 12C DCMR Electrical 12E DCMR Mechanical 12F DCMR Plumbing 12D DCMR Fuel Gas 12I DCMR Chapter 11A DC Construction s 2008 12H DCMR Fire Prevention 12H DCMR Fire Prevention 12G DCMR District of Columbia (DC) Mandated, Effective March 28, 2014 Base 2013 Construction ) Construction ) Construction ) Electrical Construction ) Mechanical Construction ) Plumbing Construction ) Fuel Gas with Construction 2013 Construction ) 2013 Green CC 2013 Fire Construction ) 2013 Fire Construction ) 2013 Construction ) Florida (FL) Mandated Base Electrical Mechanical Mechanical Plumbing Plumbing Fuel Gas Fuel Gas Efficiency 2012 Florida Accessibility 2010 ADA Standards for Accessible Design Fire Prevention Fire Prevention 2009 NFPA 101 2009 NFPA 1 Page 2 of 11
s in Effect by Mandated or Georgia Georgia Minimum Standard Building One and Two Family Dwelling Electrical Mechanical Plumbing Fuel Gas Efficiency Accessibility Life Safety Fire Georgia Electrical Georgia Mechanical Georgia Plumbing Georgia Gas Georgia Georgia Access Law, Chapter 120-3-20 Georgia Fire Georgia Fire Georgia (GA) The building, one and two family dwelling, fire, plumbing, mechanical, gas, electrical and energy codes are Mandated codes. Base 2009 optional Electrical Mechanical Plumbing Fuel Gas 2011, 2012 s and Fire Fire 2009 optional Hawaii (HI) The Four County jurisdictions have 2 years in which to adopt and amend the with local amendments. If the county jurisdictions do not comply within the 2 year time line then the becomes the county's code until such time the county passes an adopting ordinance. Base (MANDATED) Electrical (MANDATED) Mechanical - 2006 Uniform Plumbing (subject to 2010 (MANDATED) (MANDATED) 2006 Uniform Fire 2006 Uniform Fire Idaho (ID) s adopted at local levels except for state owned building and public schools, modular and manufactured homes. IDAPA 07.03.01 07.03.01 07.03.01 07.01.06 07.07.01 07.02.06 07.07.01 07.03.01 Base, 2012 01/01/2015 2014 National Electrical Mechanical,2012 1/01/2015 Plumbing Fuel Gas,2102 01/01/2015 2006 ICC/ANSI 18.01.50 Idaho fire prevention code Fire safety Fire Fire Illinois (IL) Some codes are Mandated if any area has not adopted local codes. is any building other than single family or two or less units. The Illinois Board of Education has adopted the 2009 IBC, IFC, IMC, IFGC, IPMC, IECC, IEBC for Pre-K thru 12 public Education Facilities (except Chicago) Base () () Electrical Illinois Plumbing, Revised Edition 2012 Illinois. ASHRAE 90.1 2010 Illinois Accessibility, Enviromental Barriers Act 410ILCS 25 2000 NFPA 101 2000 NFPA 101 Page 3 of 11
s in Effect by Indiana (IN) Mandated or Mandated Base 2008 Indiana 2005 Indiana 2008 Indiana Electrical Mechanical Plumbing Fuel Gas Efficiency Accessibility Life Safety Fire 2009 Indiana Electrical 675IAC 17 Electrical 2008 Indiana Mechanical 675 IAC 18 Mechanical 1999 Indiana Plumbing 675 IAC 16 1997 Uniform Plumbing / 1998 American Society of Sanitary Engineers Standard 1051 2008 Indiana Fuel Gas IAC 25 Fuel Gas 2010 Indiana ASHRAE 90.1, 2007 2008 Indiana 2008 Indiana Fire IAC 22 Fire state 2008 Indiana Fire Fire state Must be maintained in compliance with rules of the commission or its predecessor. 675 IAC 12-4-9 Iowa (IA) Local adoption of state code. The 2009 IFC is STATE MANDATED for all Iowa. Historic 661 ch 350 Base, Chapter 301 Electrical, Chapter 301 Mechanical, Chapter 301 Plumbing, Chapter 226, Chapter 303, Chapter 302 2010 ADA Standards for Accessible Design Fire 2009 (governs ALL Iowa ) Fire 2009 (governs ALL Iowa ) Kansas (KS) The only STATE MANDATED code is the 2009 IECC and Fire code. The state does not mandate the remaining codes unless it is a state building. Base Kansas fire prevention code code Electrical Mechanical 2006 Uniform Plumbing code 2002 NFPA 54 (governs ALL buildings) code NFPA 101-2006 IFC 2006 IBC 2006 UBC 1997 Mandated wide Kansas Fire Prevention NFPA 101-2006 IFC 2006 IBC 2006 UBC 1997 Mandated wide Kentucky (KY) Louisiana (LA) Mandated Mandated new code 1/1 2014 Base Base Louisana state building code, (Excluding Ch. 1,11,27,29) (chapter 34) (Excluding Ch. 1) KRS 227 815 KAR 35:015 Electrical - NFPA 70 state Electrical Mechanical - 2006 NFPA 54 Mechanical Kentucky Plumbing 2013 Louisiana Plumbing Fuel Gas state - 2009 NFPA 54 eff 01/1/2016 IPC Fuel Gas 2009 IECC with Kentucky amendments chapter 11 Kentucky Fire as referenced in IBC Kentucky Building Fire as referncesed in IBC 2012 NFPA 101 2012 NFPA 1 Page 4 of 11
s in Effect by Maine (ME) Mandated or STATE MANDATED for communities over 4,000, (under 4000 do not need to enforce) except select codes that are APPROVED as noted. Base Maine Uniform Building and (MUBEC) Electrical Mechanical Plumbing Fuel Gas Efficiency Accessibility Life Safety Fire Electrical Mechanical Plumbing 2009 NFPA 54-2007 ASHRAE 70.1 2009 NFPA 101 2009 NFPA 1 Maryland (MD) (MA), adopted at local level. MANDATED for Industrial. Subdivisions must adopt Mandated Base Base Maryland Building Performance Standards Building, 8th Edition Maryland Building Performance Standards Building, 8th Edition 2009 Maryland Building Performance Standards Building, 8th Edition Electrical Electrical Mechanical Mechanical 2012 National Standard Plumbing Plumbing 2012 NFGC Building, 8th Edition Electrical Uniform Plumbing with (527 CMR 12.00) (248 CMR) - ASHRAE 90.1 2012 Maryland Accessibility COMAR05.02.02 Architectural Access (CMR 521) 2012 NFPA 101 2009 NFPA 1 NFPA (527 CMR 21) NFPA (527 CMR 21) Maryland Minimum Livability Specialized s Michigan (MI). The of Michigan enforces a single state code that is required to be enforced by every governmental entity that elects to enforce the code. The code cannot be amended. New for 10/2014 2012 ICC Base Michigan Building 2009 2012 Michigan 2009 2012 Michigan Rehabilitation for 2009 2012 Michigan Electric 2008 2011 National Electrical with Part 8 Technical Michigan Mechanical 2009 2012 Mechanical Michigan Plumbing 2009 2012 Plumbing Fuel Gas Michigan Uniform 2009 Michigan Fire Prevention Michigan Fire Prevention NFPA 101 NFPA 101 Minnesota (MN) Mandated. Local fire codes are also acceptable, only if they are more stringent. In process of adopting 2012 ICC Base 2007 Minnesota Building with for the Rehabilitation of Structures 2014 National Electrical 07/01/2014 Mechanical 2009 Minnesota Plumbing Fuel Gas Minnesota / Minnesota ANSI/ASHRAE 90.1 2004 Minnesota Accessibility ICC/ANSI Fire Fire Page 5 of 11
s in Effect by Mississippi (MS) Missouri (MO) Mandated or. The of Mississippi has approved codes that are used for licensure testing. However, code adoption and enforcement is done at the local level. Building codes in Missouri are adopted and enforced at the local level. Base Minimum 2006, Missouri Design For state owned facilities latest ed Base of IBC, NEC, NFPA 101, Electrical Mechanical Plumbing Fuel Gas Efficiency Accessibility Life Safety Fire 2005 National Electrical Mechanical Plumbing Fuel Gas Mississippi NFPA Mississippi Fire, 2012 IBC, 2012 IRC ADAAG Chapter 24.301 Ch 24.301.154 Ch 24.301.171 Ch 24.301.401 Ch 24.301.172 Ch 24.301.301 Ch 24.301.173 Ch 24.301.161 ADAAG Montana (MT) Mandated Base Electrical Mechanical Plumbing Fuel Gas Uniform Fire Uniform Fire with with Nebraska (NE) Electrical, Mechanical, Fuel/Gas, and Life Safety are STATE MANDATED. Remaining codes are adopted and enforced at local levels, except as noted. Base Construction inspected by Fire Marshall Statute 71-6403 Exisiting Building 2002 NFPA 70 2001 NFPA 85 2002 NFPA 54 2000 NFPA 101 2003 NFPA 1 NAC 477.281 Nevada Revised Statutes, Title 28, Chapter 338.180 Nevada (NV) Mandated. Local codes may be more stringent. Base Electrical 2006 Uniform Mechanical 2006 Uniform Plumbing 2006 NFPA 54 (Applies only to public buildings and facilities, stateowned buildings and public schools) Fire Fire New Hampshire (NH) Mandated, except for property maintenance Base New Hampshire Building Electrical Mechanical Plumbing New Hampshire Fire NFPA 54 2006 ICC/ANSI New Hampshire Fire New Hampshire Fire Fire - NFPA Fire - NFPA 101 101 Page 6 of 11
s in Effect by Mandated or 5.23.3 Rehab Sub-code 5:23-6 updated yearly Electrical Mechanical Plumbing Fuel Gas Efficiency Accessibility Life Safety Fire New Jersey s New Jersey (NJ) Mandated Base Electrical Mechanical 2009 National Standard Plumbing Fiel Gas ASHRAE 90.1-2007 ANSI -2003 Fire Fire New Mexico (NM) Mandated, also has earthen building code Base 2009 New Mexico 14.7.2 NMAC 14.7.3 NMAC 14.7.7 NMAC Exitsing Building Electrical Mechanical Plumbing 2009 New Mexico Plumbing Ch. 8/New Mexico Mechanical Ch. 9 14.7.6 NMAC 1998 ICC/ANSI Fire Fire New York (NY) Mandated (except New York City) Base Building NFPA 70 Mechanical Mechanical Plumbing Plumbing 2010 Fuel Gas of New York Fuel Gas Building ADA 2010 Fire of New York Fire 2010 Fire of New York Fire 2012 North Carolina Building 2012 North Carolina 2009 North Carolina Rehabilitation 2011 North Carolina Electrical 2012 North Carolina Mechanical 2012 North Carolina Plumbing 2012 North Carolina Fuel Gas Chapter 11 of 2012 North 2012 North 2012 N.C. Building Carolina Fire Carolina Fire North Carolina (NC) Mandated Base Electrical Mechanical Plumbing 2009 Internationa Fuel Gas 2012 North Carolina 2003 ICC / ANSI 117.1 Fire Fire North Dakota Effective 1/1/2014 (ND) codes are Mandated for and Schools. Also, state codes are only Mandated if local jurisdictions elect to adopt them. Base 2014 North Dakota Building Electrical Mechanical Plumbing Fuel Gas (ch.13) (ch.11) Fire NFPA 101 2009 Fire NFPA 101 2009 Page 7 of 11
s in Effect by Ohio (OH) Mandated or Mandated; U.S. government and military structures and agricultural buildings do not have to follow a building code. Base 2011 Ohio 4101:1 of Ohio 4101:8 2011 Ohio Electrical Mechanical Plumbing Fuel Gas Efficiency Accessibility Life Safety Fire Electrical NFPA 70 2011 Ohio Mechanical 4101:2 Mechanical 2011 Ohio Plumbing 4101:3 Plumbing Fuel Gas & ASHRAE 90.1 2007 2011 Ohio 2011 Ohio Fire Fire 2011 Ohio Fire Fire Oklahoma Uniform Oklahoma (OK) Mandated Base Electrical Mechanical Plumbing Fuel Gas ASHRAE 90.1 Fire Fire Oregon (OR) Mandated new 71/2014 Base 2014 Oregon Structural Specialty 2011 Oregon Specialty 2014 Oregon Structural Specialty Chapter 34 2011 Oregon Electrical Specialty Electric 2014 Oregon Mechanical Specialty Mechanical 2011 Oregon Plumbing Specialty Plumbing Fuel Gas 2014 Oregon Efficiency Specialty 2014 Oregon Structural Specialty Chapter 11 2012 IECC 2010 Oregon Fire Fire 2010 Oregon Fire Fire Pennsylvania Uniform Construction Uniform Uniform Construction Construction Chapter 405 Chapter 405 Pennsylvania (PA) Mandated Base, omit Chapter 1 & 30, adopt appendix H. with Appendix G with all Appendices or Ch. 34 IBC Electrical, NFPA 70 Mechanical Plumbing Fuel Gas 2012 IBC Chapter 11, Appendex E, Fire Fire 2009 ANSI Rhode Island (RI) Mandated SBC-1-2013 Rhode Island Building SBC-2 Rhode Island One and Two Family Dwelling SRC-1 Rhode Island Rehabilitation Building and Fire for and Structures SBC-5 Rhode Island Electrical SBC-4 Rhode Island Mechanical SBC-3 Rhode Island Plumbing SBC-19 Rhode Island Fuel Gas SBC-8 Rhode Island Rhode Island Uniform Fire Rhode Island Uniform Fire SBC-6 Base Electrical Mechanical Plumbing Fuel Gas 2003 NFPA 101 2003 NFPA 1 Page 8 of 11
s in Effect by Mandated or Electrical Mechanical Plumbing Fuel Gas Efficiency Accessibility Life Safety Fire South Carolina (SC) Mandated, as shown. Local jurisdictions may use more stringent codes and are responsible for interpretation and enforcement of codes. Base South Carolina 2006 IBC 2006 IRC 2006 IEBC(APPROVED ) Electrical 2008 NEC Mechanical 2006 IMC Plumbing 2006 IPC Fuel Gas 2006 IFGC 2009 ECC latest edition / ANSI 2012 Fire Fire South Dakota (SD) Fire safety mandated for schools and daycare centers.. s are mandated where local jurisdictions do not have their own building codes. In the case where they do, the local codes are the ones which are followed. Base 61:15:01 Fire safety Electrical Fire safety Mechanical Plumbing Fire Fire safety Fire Fire safety Fire Tennessee (TN) Mandated, except licensed health-care facilities, see 1200-08- 01-.08. Local may be more stringent. Base Electric NFPA 70 Mechanical Plumbing ASHRAE 90.1-07 2005 Tennessee Public Building Accessibility Act Fire, 2006 NFPA 101 Fire, 2006 NFPA 1 Texas (TX) buildings must conform to latest ICC codes. s are adopted and enforced at a local level, except as indicated. 214.216, 70.101 214.212 1305.101 rule 367.1 2012 TAC ch. 469 Base 2009 IBC 2009 IRC Ch 34 IBC 2011 NFPA 70 2009 IMC or 2009UMC 2009 IPC or 2006 UPC 2009 IFGC ASHRAE 90.1-07 Fire Marshall 2012 NFPA 101 2012 NFPA 101 Utah (UT) Mandated; enforcement is done at local level. Base Construction Title 15a-ch2-sec 103 (including Appendix J with Construction Construction Construction Electrical Construction Mechanical Construction Plumbing Construction Fuel Gas Construction 2009 ICC/ANSI Utah Fire, Section15a-5-103; Construction Construction Fire Fire Page 9 of 11
s in Effect by Vermont (VT) Mandated or Mandated, except for single family dwellings Base 2012 Vermont Fire and Building Safety with NFPA 101 2012 2014 NFPA 70 Electrical Mechanical Plumbing Fuel Gas Efficiency Accessibility Life Safety Fire 2006 Uniform Fire, NFPA 1 & NFPA 90 Plumbing National Building Inspection 2004 2011 Vermont Building Standards 2012 Vermont Accessibility Rules 2012 NFPA 101 2012 NFPA 1 Virginia (VA) Mandated, eff 07/14/2014 Base Uniform wide Uniform wide I, Ch. 2-35 Rehabilitation II Uniform wide Electrical Uniform wide Mechanical Uniform wide Plumbing Uniform wide Fuel Gas Uniform wide 2012 Uniform wide 2009 ICC/ANSI Uniform wide Fire Uniform wide Fire III, Ch. 2-8 Washington WAC 51-50 WAC 51-51 WAC 51-52 WAC 51-56 WAC 51-11c WAC 51-11r WAC 51-54 Washington (WA) Mandated Base w/ Appendix E and 2009 ICC/ANSI with w/ Appendices F and G (omit Ch. 11 and 25 through 42) with, with 2008 NEC 2008 on July 1, 2014 the 2014 NEC will be used Mechanical 2011 NFPA 58 2012 NFPA 54 2012 Uniform Plumbing w Appendices A, B, and I with Mechanical with NFPA 58 NFPA 54 2012 Washington ; 2009, Ch. 10 and 11; 2009 ICC/ANSI 2006 NFPA 101 Fire 2012 NFPA 101 Fire West Virginia (WV) Mandated Through fire marshall, counties must adopt state code Base West Virginia eff. 9/1/2013, omit Fire Prevention, Section 101.4.5, some exceptions apply Electrical (NFPA 70) Mechanical Plumbing 2012 National Fuel Gas NFPA 54,58 2009 ICC/ANSI 2009 NFPA Life Safety 2009 NFPA Life Safety Page 10 of 11
s in Effect by Wisconsin (WI) Mandated or Mandated, however, municipalities may choose stricter codes Base 2011 Wisconsin SPS 360-366, Uniform Building SPS 320-321, Wisconsin SPS366 Electrical Mechanical Plumbing Fuel Gas Efficiency Accessibility Life Safety Fire Electrical SPS316 Mechanical Wisconsin Wisconsin 365 Fuel Gas Wisconsin 363 2009 ICC/ANSI CH. 14, 30 2009 NFPA-1 2009 NFPA-1 Wisconsin Wyoming (WY) STATE MANDATED, except for plumbing, which is adopted and enforced at a local level. Many of the codes are only adopted to the extent as they are referenced in the IBC, IMC, IFGC, and IFC Base does not amend the code but offers variances Provisions of 2012 (as referenced in IBC, IMC, IFGC, and IFC, all 2012) that apply to Life Safety (as referenced in IBC, IMC, IFGC, and IFC, all 2012) Electrical Mechanical Fuel Gas Not adopted WS 16-6-501 WS 16-6-502 Fire w/ Appendix D, E, F, and G Fire w/ Appendix D, E, F, and G (as referenced in IBC, IMC, IFGC, and IFC, all 2012) that apply to life safety Page 11 of 11