UFGS-02362 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS



Similar documents
UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

Proposed Minimum Subterranean Termite Treatment Standards

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

Section 2100-Trenching and Tunneling

UNIFIED FACILITIES GUIDE SPECIFICATIONS ************************************************************************** SECTION TABLE OF CONTENTS

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Division 2 Section Section 02795

SECTION PERMEABLE INTERLOCKING CONCRETE PAVEMENT

SECTION EARTH MOVING

SECTION PRECAST CONCRETE UTILITY STRUCTURES

UNIFIED FACILITIES GUIDE SPECIFICATIONS

CW 3110 SUB-GRADE, SUB-BASE AND BASE COURSE CONSTRUCTION TABLE OF CONTENTS

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

C. Section TESTING LABORATORY SERVICE.

40-9 PERMEABLE INTERLOCKING CONCRETE PAVEMENT

SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP)

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

SECTION PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Wastewater Capital Projects Management Standard Construction Specification

Building Your Interlocking Concrete Pavement to Last a Lifetime

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

STANDARD SPECIFICATIONS SECTION PRECAST REINFORCED CONCRETE MANHOLES AND MANHOLE BASES. 1. Structure Earthwork: 02200

SANITARY SEWER SERVICE CONNECTION INSTRUCTIONS

DRAFT TERMITE PROTECTION IN BUILDINGS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

UFGS (July 2007) UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION UNI PERMEABLE INTERLOCKING CONCRETE PAVEMENT

SECTION 1 GENERAL REQUIREMENTS

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Residential Building Permits Information

PERMEABLE INTERLOCKING CONCRETE PAVEMENT

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

SECTION STORM DRAINAGE SYSTEM

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

The Manitoba Water Services Board SECTION Standard Construction Specifications PIPE EXCAVATION, BEDDING AND BACKFILL Page 1 of 11

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

SECTION PERVIOUS INTERLOCKING CERAMIC PAVERS

SECTION PERMEABLE INTERLOCKING CONCRETE PAVEMENT (1995 MasterFormat Section 02795)

Section 402. STORM SEWERS

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

MDWASD 8/1999 SECTION TRENCHING AND BACKFILLING FOR PIPING SYSTEMS

Storm Drain Inlet Protection - IP

STANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION

Lighthouse Engineering, L.L.C.

STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope

Specification for Cast-in-Place Concrete Pipe

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Chapter 3 CULVERTS. Description. Importance to Maintenance & Water Quality. Culvert Profile

SIENA STONE GRAVITY RETAINING WALL INSTALLATION SPECIFICATIONS. Prepared by Risi Stone Systems Used by permission.

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

UFGS (January 2001) UNIFIED FACILITIES GUIDE SPECIFICATIONS

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

SECTION GRAVITY SANITARY SEWERS

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

SECTION 4Aggegate Subbase

Termiticide Use Restrictions in Delaware

UNIFIED FACILITIES GUIDE SPECIFICATIONS ************************************************************************** SECTION TABLE OF CONTENTS

A Guide To The New Termite Standards (revised 09/02/2001)

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS

THE METALITH PERIMETER SECURITY SYSTEM INSTALLATION INSTRUCTIONS. Attention

SUDAS Revision Submittal Form

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

Seven. Easy Steps. Your Own Walkway, Without Mortar. or Concrete. to Installing. Driveway and Patio

UFGS (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

SECTION CHAIN LINK FENCES AND GATES

Permeable Pavement Construction Guide

Code of Standard Practice for Timber Frame Structures

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Premium Nixalite All Stainless Steel Bird Barrier Spikes Includes specifications for: Premium Nixalite Models S, H and W and Mounting Hardware.

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

INFORMATION SHEET ON TERMITES & TERMITE MANAGEMENT PROCEDURES

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

CHAPTER 6 - SANITARY SEWER

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

Elevating Your House. Introduction CHAPTER 5

3. Amend the following: Item 410 Traffic Compacted Surface, Type C to Item 446 Cold Patch.

State of Connecticut Department of Public Health RADON PROGRAM

Beacon Hill Sewer District Standard Specifications

Renovating Your Basement

Transcription:

USACE / NAVFAC / AFCEC / NASA UFGS-31 31 16.20 (April 2006) Change 2-11/14 ----------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-02362 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with UMRL dated October 2015 SECTION TABLE OF CONTENTS DIVISION 31 - EARTHWORK SECTION 31 31 16.20 BASALTIC TERMITE BARRIER 04/06 PART 1 GENERAL 1.1 REFERENCES 1.2 SUBMITTALS 1.3 STORAGE AND HANDLING 1.4 WARRANTY PART 2 PRODUCTS 2.1 BASALT SAND PART 3 EXECUTION 3.1 INSTALLATION 3.2 PLACEMENT 3.2.1 Slab-on-Grade 3.2.1.1 Utility Trenches 3.2.1.2 Edges 3.2.2 CMU Block Walls 3.2.3 Fence Posts and Utility Poles 3.2.4 Retaining Walls -- End of Section Table of Contents -- SECTION 31 31 16.20 Page 1

USACE / NAVFAC / AFCEC / NASA UFGS-31 31 16.20 (April 2006) Change 2-11/14 ----------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-02362 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with UMRL dated October 2015 SECTION 31 31 16.20 BASALTIC TERMITE BARRIER 04/06 NOTE: This guide specification covers the requirements for a basaltic termite barrier. Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information. Remove information and requirements not required in respective project, whether or not brackets are present. Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR). NOTE: This specification consists of furnishing and placing of graded basaltic sand as a physical barrier, below the concrete slab or foundation of a structure to prevent the entry of Formosan ground termites into wood components of the structure, similar to laying down a chemical barrier of soil termiticide treatments. The use of this preventive measure does not preclude the use of other preventive measures such as chemical treatment, physical termite mesh control barrier system and and pressure treated lumber for construction to provide maximum protection to the structure. In fact, it is recommended that this material be used in conjunction with chemical treatments of vulnerable areas such as around electrical conduits, plumbing pipes that penetrate the slab, and the shoulder portions of the barrier and with pressure treated lumber to provide maximum protection to the SECTION 31 31 16.20 Page 2

structure. NOTE: TO DOWNLOAD UFGS GRAPHICS Go to http://www.wbdg.org/ccb/navgraph/graphtoc.pdf. PART 1 GENERAL 1.1 REFERENCES NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title. Use the Reference Wizard's Check Reference feature when you add a RID outside of the Section's Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizard's Check Reference feature to update the issue dates. References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process. The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. ASTM INTERNATIONAL (ASTM) ASTM C128 ASTM C131/C131M ASTM C136/C136M ASTM C289 (2015) Standard Test Method for Density, Relative Density (Specific Gravity), and Absorption of Fine Aggregate (2014) Standard Test Method for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (2014) Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates (2007) Standard Test Method for Potential Alkali-Silica Reactivity of Aggregates (Chemical Method) 1.2 SUBMITTALS SECTION 31 31 16.20 Page 3

NOTE: Review Submittal Description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. The Guide Specification technical editors have designated those items that require Government approval, due to their complexity or criticality, with a "G". Generally, other submittal items can be reviewed by the Contractor's Quality Control System. Only add a G to an item, if the submittal is sufficiently important or complex in context of the project. For submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the "G" designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: "AE" for Architect-Engineer; "DO" for District Office (Engineering Division or other organization in the District Office); "AO" for Area Office; "RO" for Resident Office; and "PO" for Project Office. Codes following the "G" typically are not used for Navy, Air Force, and NASA projects. An "S" following a submittal item indicates that the submittal is required for the Sustainability Notebook to fulfill federally mandated sustainable requirements in accordance with Section 01 33 29 SUSTAINABILITY REPORTING. Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects. Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are [for Contractor Quality Control approval.][for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.] Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-02 Shop Drawings Installation ; G[, [ ]] Shop drawings of the basaltic termite barrier installation at all interior and perimeter foundations, joint and penetration conditions. SD-06 Test Reports Basalt Sand ; G[, [ ]] SECTION 31 31 16.20 Page 4

SD-08 Manufacturer's Instructions Manufacturer's Installation Instructions ; G[, [ ]] Preprinted material describing installation of a product, system, or material, including special notices and Material Safety Data sheets concerning impedances, hazards and safety precautions SD-11 Closeout Submittals 5 Year Written Warranty ; G[, [ ]] Written warranty required in paragraph entitled "Warranty" and signed jointly by an officer of the Contractor and the supplier. 1.3 STORAGE AND HANDLING Store and handle the material so as to prevent contamination by dirt, water, and organic material. 1.4 WARRANTY NOTE:Use 5 years for family housing and 3 years for other types of facilities. Provide a minimum 1 year warranty against infestations or reinfestation by subterranean termites of existing buildings with basaltic termite barrier (BTB) installed during repair or renovation. Furnish a 5 year written warranty against infestations or reinfestation by subterranean termites of the buildings or building additions constructed under this contract. Perform annual inspections of the building[s] or building addition[s]. If live subterranean termite infestation or subterranean termite damage is discovered during the warranty period, and building conditions have not been altered in the interim, the Contractor shall: a. Correct defective BTB installation and perform other treatment as may be necessary for elimination of subterranean termite infestation; b. Repair damage caused by termite infestation; and c. Reinspect the building approximately 180 calendar days after the repair. PART 2 PRODUCTS 2.1 BASALT SAND Clean, dry sand material manufactured from crushed basalt rock meeting the following requirements. a. Material gradation, ASTM C136/C136M. SECTION 31 31 16.20 Page 5

Sieve Size Percent Passing 4.75 mm 100 2.36 mm 95-100 2.00 mm 75-95 1.70 mm 35-50 1.18 mm 0-10 Sieve Size Percent Passing No. 4 100 No. 8 95-100 No. 10 75-95 No. 12 35-50 No. 16 0-10 b. Specific gravity, ASTM C128, 2.80. c. Silica (S102) content, ASTM C289, 45 percent. d. Abrasion loss, after 500 revolutions, 20 percent, when tested in accordance with ASTM C131/C131M. PART 3 EXECUTION 3.1 INSTALLATION Install basaltic barrier in accordance with the manufacturer's installation instructions. In addition to these requirements and prior to placing material, remove visible plant roots,construction wood scraps such as ground stakes, form boards, and scrap lumber, and standing water from the excavated area. Inspect utility trenches to ensure they are sufficiently wide to permit adequate cover under, around, and over pipes and conduit that will be encapsulated with the BTB materials. Also inspect the foundation perimeter to ensure that there is sufficient room between the sides of excavations and edges of foundations to provide the required barrier depth and width. 3.2 PLACEMENT Place material in one lift for thicknesses of 150 mm 6 inches or less and in successive lifts of 100 to 150 mm 4 to 6 inches where the indicated thickness is greater than 150 mm 6 inches. Compact each lift prior to placing successive lifts. Use power driven, vibrating-plate type tampers for large areas and rod-and-plate type hand tampers for small areas such as utility trenches and foundation and walk edges. SECTION 31 31 16.20 Page 6

3.2.1 Slab-on-Grade NOTE: Show the required depths on the drawings. 100 mm Four inch depth is the minimum required. For areas where capillary action is a problem, consult a soils engineer if the depth should be increased or other capillary prevention measures are required. Provide a barrier of the depth indicated. Rake smooth and machine tamp, giving at least three passes over the entire area. Hand tamp around pipe and conduit risers. 3.2.1.1 Utility Trenches Place the required depth of material for bedding in trenches prior to placing pipes and conduits and hand tamp the material. For pipes 75 mm 3 inchesand larger in diameter: After placing pipe, bring material up to the top of the pipe and carefully hand tamp the material. Then, bring material up to the top of the trench and tamp. For pipes smaller than 75 mm 3 inches in diameter and for conduit: Bring material up to the top of the trench and tamp. 3.2.1.2 Edges After concrete placement and form removal, remove dirt, loose concrete, and other debris and hand place and tamp additional material to existing grade. 3.2.2 CMU Block Walls Place the material in ungrouted cells at a height of at least one course above grade of the wall. 3.2.3 Fence Posts and Utility Poles a. Line the designated hole with a geotextile or similar material before proceeding with the work. b. Once the geotextile is in place, put a 100 to 150 mm 4 to 6 inch layer of the BTB at the bottom of the hole. Hand tamp. After positioning the fence post or utility pole in the middle of the hole, fill around the sides, compacting the material after successive lifts of 150 to 300 mm 6 to 12 inches until the hole is completely filled. Ensure that a 100 to 150 mm 4 to 6 inch BTB barrier exists around the perimeter of the post or pole. 3.2.4 Retaining Walls Place the required amount of material below the footing and up to the grade level of the wall. Place lifts of 100 to 150 mm 4 to 6 inches with compaction of each lift prior to placing successive lifts. -- End of Section -- SECTION 31 31 16.20 Page 7