Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector



Similar documents
Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

2006 Codes. Please verify the following before calling for inspection

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004

Top 10+ Mistakes of DWV plumbing design

What to Expect From the Examination. How to Study the Plumbing Codes

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

When Should Examination Preparation Begin?

PLUMBING PERMIT APPLICATION (PLUMBING PERMIT TO BE SECURED 24 HOURS BEFORE WORK STARTS)

ONTARIO PLUMBING INSPECTORS ASSOCIATION INC. In the public service since Wet Venting. Incorporating Stack Venting and NPC Harmonization

2010 Residential Water Heater Replacement Check List

PLUMBING. For HOME OWNERS

Self-Home Inspection Checklist

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

Chapter 7 Plumbing Connections

CHAPTER 9 VENTS TRANSPORTATION OF SEWER GAS

Understanding and Designing Plumbing Systems

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

Isometric Plumbing Drawings

CLARK COUNTY DEPARTMENT OF BUILDING COMMERCIAL PLUMBING AND MECHANICAL INSPECTION CHECKLISTS 2006 CODE

PLUMBING ROUGH IN INSPECTION

CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS

Plumbing Identification and Damage Assessment Guide

2. What building projects are exempted? (permit not required)

ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007

SECTION Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)

Residential Plumbing BCN 1058

Amendments to the 2012 International Plumbing Code

BUILDING PERMIT SPECIFICATIONS

PMA ONLINE TRAINING Venting for Plumbing Systems

WINTERIZING YOUR HOME PLUMBING AT BLUE RIDGE SHORES

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Residential Plumbing

YOUR HOME S PLUMBING SYSTEM By Tim Oglesby, Home Check America

BASEMENT FINISH PERMIT AND BUILDING CODE REQUIREMENTS (REVISED 3/20/2009)

PDmB, Inc. Definitions

WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION

Cost Estimation for Materials and Installation of Hot Water Piping Insulation

Uniform Construction Code (UCC) Building Permit Application Package

Arapahoe County Residential Water Heater Installation and Inspection Guide

To many people, a home s plumbing system is perceived as being extremely

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

Why Do I Have Sewer Smells In My Home or Business?

Dominic i Barbato Dpt. Of Building and Safety (818) domenico.barbato@lacity.org

Georgia Association of Home Inspectors

Propery Inspection Report

Does Wall Township require an inspection by the building department on resale of a home?

October 5, 2015 Dear Client,

Town House Center Highway North Huntingdon, PA 15642

Building Condition Assessment Report

Borges Construction Company A limited liability Corporation Page1 of 1

Pre-Drywall Inspection Report

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

LEAK DETECTION GUIDE

Orlando Home Inspection Services

Guide for Efficient Hot Water Delivery Systems

HV AC CODE CHECKLISTS

HomeSpec REPORT SUMMARY

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Building Condition Assessment Report

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

PLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2014 LAPC

RRIO Checklist. Use of checklist: Definitions: Limitations

The City of Basehor, Kansas

BUILDING TRADES II PLUMBING: ROUGH-IN AND FINAL TEACHER S GUIDE

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PLUMBING SPECIALTIES

Report for. Dick and Jane Homeowner Lovers Lane, Houston, Texas 77000

HAZELBAKER CONSTRUCTION SERVICES 8965 QUARRY DRIVE NAPLES, FLORIDA (239)

SIZING OF WATER PIPING SYSTEM

C I T Y O F S E L M A F I R E D E P A R T M E N T

NAVIEN AMERICA INC FITCH AVENUE

SWF Home Inspections

Plumbing Code in Commercial Kitchens

Saving Water and Energy in Residential Hot Water Distribution Systems. Gary Klein California Energy Commission

Thermal Imaging for Home Inspectors

FINISHED BASEMENT REQUIREMENT GUIDE

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Inspecton Report. Property Address:

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Applications for building permits will not be reviewed until all of the required information has been submitted.

Plugging Home Drains to Prevent Sewage Backup

GENERAL ELECTRICAL REQUIREMENTS

Schedule of Maintenance Fees

Plumbing Apprenticeship Program Curriculum

CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY

CONSTRUCTION PERMIT APPLICATION AND INSTRUCTIONS (Permit Application follows instructions)

Sewage Compliance Form Instructions

FILLING AND PURGING THE SYSTEM

A TO Z HOME INSPECTIONS PROFESSIONAL HOME INSPECTION SERVICES FOR HOME BUYERS AND SELLERS

Plumbing Supply Piping Planning Tool Reducing Water Wasted Waiting for Hot

City of Elk River BASEMENT Office Use Only

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

How To Make A House Safe

Transcription:

Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015

Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination Y-1/8 Double combination Fixture Y-1/8 Fitting Vent 90, This fitting is to be used in the venting system only. This is not a drainage fitting because of its short sweep. Medium 90, This fitting can be used in the drainage system from a horizontal drain to a vertical drop in a drain. This can be used anywhere in the vent system.

Waste and vent fittings Long sweep 90, this fitting can be Used anywhere in drain and vent system 1/16 bend 22 1/2 degree bend. This fitting is used to offset drain and vent pipe. Can be used in any position. 1/8 bend 45 degree bend. This fitting is used to offset drain and vent pipe. Can be used in any position. 1/6 bend-60 degree. This fitting is used to offset drain and vent pipe. Can be used in any position 2x1-1/2x1-1/2 san tee. This fitting is used for fixture connections from the wall to the trap under the sink. Combination y-1/8 bend. This fitting is used to connect a vertical drain to a horizontal drain or a Horizontal drain to a horizontal drain.

Waste and vent fittings Double Fixture fitting. Used for connecting back to back fixtures with fixture rim heights at same level or under floor for back to back toilets. This is not a double san tee. Double san tee. Used to connect two horizontal vents to a vertical stack. Fitting upside down. Double combination y-1/8 bend. This fitting is used to connect a Horizontal drains to a vertical stack. Two way cleanout tee.to be used just outside of the building foundation on the sewer drain line. Trap adapter. This is used to connect the trap under a sink to the trap arm. Coupling. Used to connect pipes together.

Drains and Vents Connection of first floor and second floor vents. Second floor sink. Second floor line Y-fitting receiving waste from second floor sink. First floor sink. San tee in vertical position. San tee in horizontal position not permitted as drainage fitting. Y-fitting receiving waste from sink. Connecting horizontal drain to horizontal drain with Y fitting. Combination y-1/8 bend in horizontal position.

Drains and Vents Fixture Drain Size Vent size Trap size Toilet 3 2 In Toilet Kitchen sink 2 1-1/2 1-1/2 Clothes washer 2 1-1/2 2 Lavatory sink 1-1/4 1-1/4 1-1/4 Laundry sink 2 1-1/2 1-1/2 Bathtub 2 1-1/2 1-1/2 Spa tub 2 1-1/2 1-1/2 Shower 2 1-1/2 2 Combined vent Toilet vent 1-1/2 vent Vent from downstairs Lavatory sink drain. Vent just below window. Use drainage fittings. 2 kitchen drain Toilet Vent going up to upstairs wall. Fixture fitting Vent from downstairs. Toilet drain in upstairs floor joist.

Drains and Vents 1/4 inch per foot grade and hanger required every 48 inches.. Cleanouts under floor must have 18 behind it for access And be within 20 foot of crawl hole. Cleanouts are required for the kitchen sink. Cleanouts on the second floor of the building are not required. Two way cleanout outside of house is preferable or a end of line cleanout may be used. A sewer line must have cleanouts every 100 foot. Green tracer wire 18 ga. on sewer. End of line cleanout. Cleanouts are required for change of direction over 135 degrees in horizontal turns. That s 1-90 degree turn and 1-45 degree turn. Cleanout above washer so it can be used without moving washer

The most common mistake is to use this san tee in a horizontal position as a drainage fitting. This is horizontal Drain pipe from sink, tub, toilet or shower is not permitted to drain into a san tee in a horizontal position. This fitting must be a combination y and 1/8 bend. See fittings page.

Vents 1. The drainage system of the building must be vented by one or more pipes whose combined cross sectional area is at least equal to that of the largest required building drain line. This means that if the building main is 3 pipe you could vent with any combination of pipes that total 7 square inches. Pipe size Diameter of pipe 1-1/4 1.2272 1-1/2 1.7671 2 3.1416 3 7.0686 2. Using the chart above a 3 sewer would require 2-2 vents and 1-1-1/2 vent, 3.1416+3.1416+1.7671=8.0503. This is large enough for the 3 sewer. Vent 6 above roof. Never terminate vents in attic space. Hose for water test of the new waste system. Vents connecting together in attic. Bath tub P-Trap Drain line Vent connection of downstairs fixtures must be 6 above the overflow rims of fixtures on this floor. Vertical vent on bathtub drain in under floor crawl space. 1-1/2 vent.

Washing Machine Rough 1-1/2 vent threw roof or combine with other vents 2 Standpipe to be a minimum of 18 to a maximum of 30 above P-trap. 2x1-1/2x2 san tee 2 P-trap Trap must be with in 6 to 18 above the floor 2 drain line

Sinks 1-1/2 vent 1-1/2 P-trap 1-1/2 trap arm can be 3 foot 6 long 2 drain line Two lavatory sinks side by side with single drain. Two lavatory sinks back to back.. Two lavatory sinks side by side using a fixture fitting tee. Lavatory wet vent drain on toilet vent. A maximum of a 3 foot 6 inch trap arm Lavatory sink with y-fitting receiving waste from second floor. Kitchen sink waste and vent.

Showers and Tubs 1-1/2 Vent San tee Shower drain, 2 Drain and P-trap. 1-1/2 vent. Shower drain, flat vent can be used where additional vertical clearance is required. See below. 1-1/2 P-trap 2 drain Bath tub drain with vertical vent. Bath tub drain with flat vent. Looking up at second floor, floor joist. Split face shower drain Pressure balance shower valve is required. Shower access box in concrete floor. Tile shower liner. Liner slopes at a 1/4 per foot towards drain.

Island Sink Waste and Vent Loop Vent One piece fitting or 2-45 and one 90. 1-1/2 vent threw roof 1 1/2 P-Trap Cleanout in sink cabinet 1 1/2 cleanout Above floor@ Nearest wall Floor line 2 Drain line 1/4 per foot grade 1-1/2 foot vent Under floor @1/4 Per foot grade Combination Fittings Y and 1/8 bend Loop vent returns to drain line downstream of fixture drain One piece fitting Loop vent to top of cabinet Rough in of loop vent and water

Toilet Rough In 12 rough from wall to center of flange 15 1/2 inches to center of flange. 30 minimum space for toilet. toilet Vents Bathtub Bathtub waste connection downstream of toilet drain. Vertical vent to wall above. Looking up at second floor, floor joist. Vent Closet bend may have long turn 90. Six foot maximum from vent to closet flange. Waste connection downstream of toilet

Toilet rough in 1.The center of the floor flange should be 12 from the wall studding behind the toilet and 15-1/2 to each side of the center of the toilet flange to wall studs, 30 space required. 2. The toilet requires a 3 drain line. Up to 3 toilets may be installed on a 3 horizontal drain line, then at the point where the 4 th. Toilet drain line enters the building drain, the drain must be increased to a 4 drain line. 3. The toilet vent cannot be used as a drain for fixtures on the second floor of the building. 4. The closet bend can be up to 6 foot long. No drains from other fixtures may enter into the closet bend. Only downstream of the vent.

Water lines 1. Water line sizing for a residential home can be quite complex, so here is a rule of thumb. Most two and three bathroom houses can be plumbed with a 1 water service to the house. Install the 1 pipe to the water heater so you will have enough water on the hot side to. There are a few things that must be done. The water pressure at the house must be 60 pounds and the total length of the pipe from the well or meter, to the farthest fixture, must be under 200 foot. No more than two fixtures may be installed on a 1/2 pipe. 2. PVC water lines are not permitted in a house, only outside in ground..water pressure can be increased with a well pump and bellows tank. Expansion tank on water heater. This is used when there is a check valve on water service. Water shut off valve in valve box, outside in ground. With water pressure over 80 psi a pressure regulator is required. House water shut off under cabinet.. Pex manifold.

Hangers and Supports Materials Type of joint.horizontal Vertical Copper pipe Soldered, Blazed 1-1/2 inch and smaller 6 foot. Each floor, and every 10 foot CPVC Solvent Cemented 1-inch and smaller 3 foot. 1-1/4 and larger 4 foot Base and each floor Mid-Story guides PEX Clamp-memory 32 inch Base and each floor Mid -story guides ABS-PVC SCH.40 Waste-Drain Pipe Solvent Cemented 4 foot Base and each floor Mid-Story guides Hang ABS or PVC waste pipe at 4 foot on center. Mid-story strap waste, vents and water lines. Strap water pipe using chart above. Under floor pipe up in joist space where it will be insulated

Hangers and Supports All piping shall be supported in such a manner as to maintain its alignment and prevent sagging.

Joints and connections Plumb-Pex clamp and fitting. Use inside house or outside in ground. All water pipe outside must be 24 deep. Rehau Pex clamp and fitting. Use inside house or outside in ground. Wirsbo Pex coupling with memory ring. Use inside house or outside in ground. Flow Guard gold pipe and fitting. One step yellow glue. Use inside house or outside in ground. Copper pipe and fitting. Soldered with lead free solder. Use inside house or outside in ground. Connection of PVC to CPVC outside of house. PVC is not allowed to be inside of house.

Joints and connections Flow Guard gold CPVC water pipe fastened to structure for hose bib outside. Outside frost proof hose bib with vacuum breaker. Wirsbo Pex water pipe fastened to structure for hose bib outside. Connection of CPVC to Polybutylene. Polybutylene is to be used outside only. The black pipe. Connection of ABS waste pipe to septic tank using a Fernco rubber coupling. Connection of valve in wall. Wall framed for valve access.

Water heaters Washer with 1-1/2 Wood screw Gate valve Temperature and pressure relief valve Relief valve drain line to approved location. Such as, Garage floor, 6 above ground outside, floor drain in basement. NOT to crawlspace. Earthquake strapping Circulating pump Heater stand in garage To be 18 high to element or burner, or be listed as flammable vapor ignition resistant. Gas vent Tank less water heater Car pole

Testing waste and water pipe for rough inspection. Hose in roof vent filling waste with water for test. Ten foot head of water. Test plug in cleanout. Filled with 30 Lb. Air. Cap all waste and water lines for test. Toilet flange with brass screws holding it to floor. Cap for test. Blue spacer ring for sub sheeting. Ten foot head of water for test of under slab plumbing. Test cap on sewer line.