PTB 311E Manual 3-in-1 Tablet Testing Instrument



Similar documents
PT-MT3 Magnetic Tablet for dynamic calibration and perodical qualification of Tablet Harndness Testing Instruments

Operating Principle of the Sample Positioning Flaps

KRAEMER Tablet Testing System

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

The Fundamentals of Spring Testing

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Accuracy and Pharmacutical

Melting Point Range. with BioCote antimicrobial protection

Dyeing Programmer DP - 01

Multi-Range Programmable DC Power Supplies 9115 Series

Keywords: Torque, calibration, uncertainty, torque tools, torque testers. Contents

User checks and maintenance of laboratory balances

iforks Product introduction

Elfring Fonts, Inc. PCL MICR Fonts

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

UTS Extended with visioNIR by Kraemer & Ischi Tablet testing equipment for checking Hardness, Diameter, Thickness, Weight and active pharmaceutical ingredient (API)

X2 series balances INNOVATIVE FUNCTIONAL SOLUTIONS

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Hand-held thermometer Model CTH7000

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Multi-Range Programmable DC Power Supplies 9115 Series

MINIMAT-EC-Servo Screwdriver Spindles

Incubator with mechanical convection

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

PERMAGRAPH L. for the computer controlled measurement of hysteresis curves of hard magnetic materials. Introduction.

MEASURING MACHINES. Pratt & Whitney METROLOGY LABORATORY. Measurement Systems, Inc.

PORTIO. Intelligent Portion Cutter. High speed cutting: Fixed weight, fixed thickness. High precision, minimal give-away.

Automatic Wheel Profile Measuring Device for Tramway Vehicles

ICH Topic Q4B Annex 5 Disintegration Test General Chapter. Step 3

SWISS MADE. Moisture Analyzers. PREMIUM AND MASTER Series 330 XM

Sterilizers with extra class

Pharmaceutical Rotary Presses. PharmaPress 800. High Speed Double Rotary Press

Navi-Radar 4000 and Navi-Sailor 4000 ECS for workboats and small crafts BIG SOLUTIONS FOR SMALL VESSELS

Pipette Calibration. Accurate Pipettes Day by Day. Ensure Operational Reliability With Service XXL. For more information

Poor quality welds Machine downtime High maintenance costs Lost revenue

DUGARD. Machine Tools Since Dugard 700L Series Heavy Duty CNC Lathes.

LEICA DNA digital levels Advantages that move you ahead. LEICA DNA digital levels

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

High Power Programmable DC Power Supplies PVS Series

Continuous Inkjet Videojet 1620 and 1650 High Resolution Micro Printers

Sierra S-Series Smart Interface Software User Manual

ROTATING MACHINES. Alignment & Positioning of. Fast, easy and accurate alignment of rotating machines, pumps, drives, foundations, etc.

Industrial Bar Code Scanners

TENSIONMETER ** code 183_LNRSTW **

DENSITY MEASURING SYSTEMS

Wi-Fi Barcode Scanner

Tube Control Measurement, Sorting Modular System for Glass Tube

SHAFT ALIGNMENT. Quick, simple and effective! PC SOFTWARE INCLUDED PRINTER CONNECTION EXPANDABLE MEASUREMENT VALUE FILTER COMPENSATION THERMAL GROWTH

LABOKLAV. Autoclaves Made in Germany.

Computerized Electronic Univesal Testing Machine WDW-20Y

Cronos -1 Gamma Object / Tool Monitors

RAINCONTROL LCD Special

MagIC Installation Manual. Point of Sales Terminals TD06014B

How To Test A Rockwell Type Hardness Tester

CFA. Carton Force Analyser

Instruction Manual FL

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

CYMAQ Marking System AS200 + DS7050 N-14

DUGARD. Machine Tools Since Dugard ECO Series Driven Tool, Slant Bed CNC Lathes.

Evaluating System Suitability CE, GC, LC and A/D ChemStation Revisions: A.03.0x- A.08.0x

YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH

Typical Aluminum GFM Mass Flow Meter

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

73 Series Spectrophotometers

Calibration Certificate

OPTICAL MEASURING MACHINES

Material test chamber with mechanical convection

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Freezers - Ultrafreezers. Platilab & Irilab Series

Industrial Bar Code Scanners

FOOD PROCESSING. Weighing systems for the demanding food manufacturing industry. Food Processing WEIGHING SYSTEMS

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Latex 3000 Tips and Tricks

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Step 11 Static Load Testing

Pipeline External Corrosion Analysis Using a 3D Laser Scanner

Harmonic oscillations of spiral springs Springs linked in parallel and in series

Digital Controllers ACTUATOR COMPATABILITY

SCHATZ - TEST Tool testing systems. SCHATZ -certest-w. Dynamic testing of torque tools

P3000 Series. Pneumatic Deadweight Testers Model P3000. Technical Data. Features

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

KNC Model 3666 Automatic Pressure Calibration System

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

VICKERS HARDNESS TESTER. HBS HBW Kc

LOCATION DEPENDENCY OF POSITIONING ERROR IN A 3-AXES CNC MILLING MACHINE

3 740 Wrist strap + shoe tester

SC Analysis Software. The software provides 5 main functions:

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

How To Use An Hm804X Series Of Power Supplies

AutoPay 80. Ticketer and paying machine

Agilent 8753ET/8753ES Network Analyzers

INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS. Published: April 1999

Procon Engineering. Technical Document PELR TERMS and DEFINITIONS

Paint Test Equipment. Stargloss Gloss Meter Data Sheet

Product Information Sheet UH36 Hi Pot Tester

Operating instructions Platform/floor scales

INTEGRATED MONITORING RECEIVER WITH MICRO SERVER STAM-IRS. 1. Features. 2. Description

TELESCOPE Motorized Lighting Suspension

Vandal-proof keypad series

Transcription:

PTB 311E Manual 3-in-1 Tablet Testing Instrument The manual tablet testing instrument PTB 311E is a dual force mode hardness test apparatus as it can be used for either linear force or linear speed increase while tablet hardness is tested. It offers a multiple point validation procedure for the built-in digital load cell. The instrument is made in strict compliance with the EP <2.9.8> and USP <1217> Pharmacopoeia. Enter the nominal test information for thickness, diameter or length and hardness as well as a batch number via the PTB 311E keyboard. Select the units to measure, mm - Inch, KP (Kilopond), N (Newton) or Sc (Strong Cobb). Now place the sample onto the sample upright in to the Thickness Jaw and start the test. The driven jaw will run forward, touch and force the tablet at its highest point to measure the thickness, thereafter it reverses back so that the sample falls into horizontal position to test its diameter (length) and immediately its hardness (tablet breaking force). The 3 result are immediately displayed and printed to a connected dot-matrix or suitable PCL5 type laser- or Deskjet printer. Repeat this until your series has been tested, get a full print-out including each individual result, date, time, serial number of the instrument, batch number of the product tested, mean value and deviations of the test series. Pharma Test Apparatebau AG Siemensstr. 5 63512 Hainburg/Germany PTAG_29-02860_PTB311E_v2.3E.docx Page 1 of 6 P: +49 6182 9532 600 F: +49 6182 9532 650 info@pharma-test.de www.pharma-test.com

In case you need to test hardness only, no problem; zero Thickness and Diameter station and perform hardness tests only. This flexibility and the reproducibility of the results have made the PTB311E series to become one of the most sold hardness testers. The flexibility and the reproducibility of the results have made this and other models, like the PTB 111E/111EP series to become one of the most sold tablet hardness testing instruments worldwide. Operating Principle Even in the existing USP and EP monographs there is no standard force setting or force increase mode established, but it is recommended to use a linear force increase rate of 20N/s. Different force settings usually cause problems when comparing results received by different supplier's instruments when testing the same tablet. The hardness result is directly influenced by the contact speed and force increase rate. Faster operated test jaw means lower reproducibility and often higher results. In order to offer the possibility to select an operating mode which will offer you similar results as the instruments you may already use, select the force mode, linear force increase or linear speed increase and select the same or similar rate. Also touch and detection force may be altered to suit the sample design specification. When the sample is touched the instrument switches to the selected mode and linear increasing rate. Which Force Mode Should Be Selected? For more than 18 years all Pharma Test hardness testing instruments offer the possibility to select either linear force or linear speed increase. Linear force increase is the recommended setting as it offers the most accurate control, as the rate of increase is directly controlled by the electronic load cell used to read the force. Also it is quite simple to validate the correct and linear operation as a tablet having a hardness of 100 Newton will be broken within 5 seconds if 20N/s had been set as force increase rate. The test of "soft" tablets often requires an increase of the standard force setting, otherwise the sample gets deformed only but does not break. Linear speed increase can also be used. Here the driving speed of the motor is kept linear. Actually if the touching force is kept low there is not too much difference in results between the two systems but it is very difficult to validate the linearity of the drive speed. Calibration and Validation Figure 1: PT-MT3 Magnetic Tablet The current USP Pharmacopeia requires the force sensor of a tablet hardness testing instrument to be calibrated periodically over the complete measuring range (or the range used for measuring samples) with a precision of 1N. All Pharma Test tablet hardness testing instrument can be statically calibrated over the complete measuring range by the use of different traceable counterweights. All instruments support the checking of at least three different points during calibration to prove the linearity of the force sensor. Furthermore, PTAG_29-02860_PTB311E_v2.3E.docx Page 2 of 6

Pharma Test offers the PT-MT3 magnetic tablets to calibrate the breakpoint detection of the whole tablet hardness testing instrument (force sensor and mechanics of the instrument). All Pharma Test tablet hardness testing instruments are fully compliant to the requirements of the current USP Pharmacopeia. The PTB 311E offers a built-in calibration and validation program for the hardness test station. To validate the hardness test station the PT-MT3 magnetic tablet or different certified weights are used. Use the PT-MT3 to qualify the correct breakpoint detection, the PT-MT3 instrument works like a tablet, it withstands force and after breaks. For the two point adjustment (zero and reference) of the load cell inside the hardness station a certified reference weight of 10 kg is used. For validation purposes the use 5 up to 30kg certified weights is recommended. All adjustment and calibration results can be printed and countersigned. To prove the linearity of the instrument, the operator can program a print-out of the force curve recorded during a test. This will show the linear increase of the adjusted force mode. Also different weights, like the PTB-CAL15 and PTB-CAL30 weight sets which include 5, 10, 15kg and 30kg (PTB- CAL30) using two additional 10kg weights for total 50kg, may be placed onto the load cell or the PT- MT and can be used to validate the linearity. Using the parallel port a Matrix or PCL5 printer can be added and using the RS232 COM port, all results can be transmitted to software running on a computer system. Figure 2: PTB-CAL15-5, 10, 15kg Weight Set PTAG_29-02860_PTB311E_v2.3E.docx Page 3 of 6

Advantages Some of the highlights the PTB 311E offers are: Select either linear force or linear speed increase (dual mode selection) Steppless adjustment of the force or speed increasing rate Entry of time and date Enter a 12 digit batch number Automatic re-start facility to speed up the testing sequence Documentation of all results using a separate Dot-Matrix or PCL5 printer Validation and calibration program for the measurement station Force curve print-out Dual point adjustment of the load cell for the hardness test station Multiple point validation (calibration) up to 30 or 50kg Programmable print-out of force increase curve Data transfer via RS-232 interface Hardness testing in compliance with the EP <2.9.8> and USP <1217> Pharmacopoeia Test program for soft gelatine capsule testing by setting up a testing distance Features The main features of the PTB 311E are: Fully USP <1217> and EP <2.9.8> compliant Dual force mode instrument with linear speed increase and linear force increase modes Multiple point validation procedure built-in Programmable print-out of force increase curve Set to test tension strength of oblongs and caplets available Standard Scope of Supply The PTB 311E comes ready to use with the following standard scope of supply: Standard Jaw set to allow hardness test of all size and shape samples Broken Sample collector Comprehensive documentation folder including: User manual QC/DQ testing certificate IQ documentation OQ documentation Conformity Declaration CE/EMC Declaration Instrument logbook PTAG_29-02860_PTB311E_v2.3E.docx Page 4 of 6

Options In addition to the standard scope of supply Pharma Test offers a broad range of accessories and options including: Tension test set to test break line force of shaped tablets 500N (PTB 511E) extended force range Recommended spare part set Full range of certified validation tools available Figure 3: Tension Strength Test Set to test tablets having a break-line (29-28550/52/53/55) PTAG_29-02860_PTB311E_v2.3E.docx Page 5 of 6

Technical Data Parameter Display Data Entry Standard Force Range Accuracy Resolution Force Settings Selectable Range Accuracy Maximum Sample Size Diameter Range Height/Thickness Range Accuracy Resolution Printer Interface Calibration Guidance Adjustments Calibrations Force Detection Reproducibility Instrument Housing Specification LED Display showing number of tests and results Numerical and Functional keys 5.0 to approximately 300N < 1N 0.074N (300N model) - 0.1482N (500N model) Linear speed or linear force increase 5.0-200 N/Second or Millimeter/Minute < 2% force or < 0.1% speed 45 mm 2.0-45.0mm 2.0-45.0mm (requires different thickness jaws) < 0.05 mm (typically 0.02mm) 0.0015 mm Interface to connect Dot-Matrix or PCL 5 Printer RS232 COM port Built-in calibration procedures the digital load cell Two point adjustment - zero and 10kg Multiple point for load cell precision using certified weights (CAL15/30/50) PT-MT3 Magnetic Tablet Stainless Steel to meet GLP requirements Bench Space Requirement L 48cm x W 24cm x H 26cm (without external printer ) Certification CE / EMC Certification Validation All components certified to USP / EP requirements All CE / EMC Certification provided All IQ & OQ documents included We reserve the right to make technical changes without any prior notice. PTAG_29-02860_PTB311E_v2.3E.docx Page 6 of 6