UPS MANAGEMENT SOFTWARE OPTIONS



Similar documents
Description UPS Management Software

UPS MANAGEMENT SOFTWARE

UPS Management Software

Options and monitoring

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS

SentryPlus. Shutdown Management Software for Windows. User s Manual

Sentry Bulldog Shutdown Management Software (For UNIX Series)

UPS-Management Software

UPS-Management Software

UPS-Management Software

UPS-Management Software

Communication and connectivity the ideal solution for integrated system management and data integrity

Network Management Card. User Manual

User and Installation Manual

NetCrunch 6. AdRem. Network Monitoring Server. Document. Monitor. Manage

securityprobe 5E Standard

Software and accessories

Connectivity. PowerShield 3. Communications Software

Introducing Tripp Lite s PowerAlert Network Management Software

UPS SNMP Watch User manual

Secure Power Always. Agility Series UPS ( VA) Chloride Connectivity Solutions. Product data sheet

Bulletin 1609 UPS Management Software

securityprobe5es -X20

Belkin Bulldog Plus. Shutdown Management Software for Windows. User s Manual

0MNU106NPB-GB. This release supersedes all previous releases. Specifications are subject to change without any prior notice. UPSMON User Manual

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

Compatible with all of the Ravica range of Intelligent Sensors it provides a complete environmental, access control and security monitoring solution.

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

SNMP Web Management. User s Manual For SNMP Web Card/Box

Firewall VPN Router. Quick Installation Guide M73-APO09-380

Network User's Guide for HL-2070N

PN5212/PN5320/PN7212/PN7320

MONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts

User s Manual Network Management Card

User s Manual. Remote Management Card RMCARD202. Intelligent Remote Management Card allows a UPS system to be managed, monitored, and configured

Dell Network Management Card. User's Guide. w w w. d e l l. c o m s u p p o r t. d e l l. c o m

Data Logger & Net Client Software (Windows, ipad, Android) Instant On. Touch. Drop & Drag Opera on. No more proprietary display equipment!

EPSON Stylus C84N. Supplement. Includes information about networking utilities and installation on Windows 98 and Me

UPS Monitoring Software. User manual Borri Power Guardian

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

RES ONE Automation 2015 Task Overview

Belkin Bulldog Plus Shutdown Management Software for Windows

SITRANS RD500 Configuring the RD500 with PSTN or GSM modems and Windows-based servers and clients for communication Objective:

Environmental Monitoring Unit

NEC Express5800 Series NEC ESMPRO AlertManager User's Guide

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

MONITORING. m 3 /s. m/s F Pa. g/m 3. Software. Data Input. M2M Transfer. Processing. XML/HTTP SNMP, GPRS/SMS. Measurement Sensors Dry contacts

IBM Tivoli Monitoring for Network Performance

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Installation and Configuration User's Guide

INTELLECT TM Software Package

1 Getting Started. Before you can connect to a network

Semaphore T BOX Applications in Data Center Facilities

How To Use 1Bay 1Bay From Awn.Net On A Pc Or Mac Or Ipad (For Pc Or Ipa) With A Network Box (For Mac) With An Ipad Or Ipod (For Ipad) With The

QuickSpecs. Overview. Compaq Remote Insight Lights-Out Edition

Multi-Homing Dual WAN Firewall Router

ABB solar inverters. User s manual ABB Remote monitoring portal

User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I Rev B

User Manual WatchPower

Server Management with Lenovo ThinkServer System Manager

Course Description and Outline. IT Essential II: Network Operating Systems V2.0

Option Network Management Software for UPS UNMS II

Network Management Proxy 5 User manual

Title Page Web/SNMP Management SmartSlot Card

Remote Supervisor Adapter II. User s Guide

PowerPanel Business Edition USER MANUAL

UPS Communicator. UPS Communicator English Manual Release

Version: UPS WEB/SNMP MANAGER. CS121 Series. Additional Components (CS121 Extensions) User Manual English

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

NetAgent. UPS SNMP Agent. User s Manual

HP Netserver/Server Server Management Reference Guide

Network Management Card

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6

UNMS II UPS Network Management System

Power Supply SNMP Interface User Manual for SRL versions

MONITORING. Software. M2M Transfer. Data Input. Processing. Reports Graphs, Excel Alarms. Logging Analysis, Alarms Various products

SNMP-NET UPS SNMP Card (Web-Based monitoring SNMP Card)

Minislot Transverse Environment Sensor 66846

SANUPS POWER MANAGEMENT SOFTWARE SANUPS SOFTWARE

RCCMD Multiple Server Shutdown Software

How To Set Up Power Supply On Windows (Windows) With Powerup (Windows 8) On Windows 7.1) On A Pc Or Windows 8 (Windows 7) On An Ipad Or Ipad (Windows Xp

ViewPower User Manual


ActiveXperts Network Monitor. White Paper

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

WebPower UPS SNMP HTTP AGENT

InsightPower Client. Shutdown Management Software for Windows 2000/XP/2003. User s Manual

Using Integrated Lights-Out in a VMware ESX environment

Opengear Technical Note

Product Description... 1 Internal Management Features... 3 Front Panel... 5 Watchdog Features... 7

Premium Server Client Software

Environment Sensor

User s Manual. Management Software for Uninterruptible Power Supply Systems

Transcription:

UPS MANAGEMENT SOFTWARE OPTIONS For SAFEPOWER EVO series of UPS & CPS Systems

UPSMAN UPSMON/UPSVIEW UPSMON CUSTOM Version: 2012-12-07 UPS MANAGEMENT SOFTWARE UPSMAN/UPSMON/UPSVIEW, and UNMS II Comprehensive UPS Administration and Alerting UNMS II Firewall UPSMAN Server + 2 Sender Windows Server UPS UPS OS/2 Shutdown! Unix Shutdown! CS121 UPSMAN Server + 2 Sender Event and scheduling configuration module and graphical monitoring interfaces Network shutdown messaging and command client module for heterogeneous networks Central Management of UPS, BACS, Environmental sensors & alarm contacts Communication via LAN/VPN, GSM, Modem, Email Customisable, user configurable graphical interface Description UPS Management Software The Software is a collection of The server module of the Software client/server modules for networks and local is UPSMAN, which communicates via RS-232, USB workstations for monitoring the status of system resources and managing operations in response to changing conditions. While just one single component module, UPSMAN, would suffice for managing a simple UPS system at the most basic level, the collection of different modules can be scaled and combined to form very elaborate and sophisticated intelligent facility management systems. These systems can range from one server serially connected or SNMP with the UPS or the UPS SNMP adapter. When UPSMAN begins, it collects the messages sent from the UPS and analyses received messages to notify the administrator/operator. Graphically all the UPSMAN actions can be monitored using the client modules Windows UPSMON, UNMS, UPSVIEW or any web-browser. The UPSMAN is able to manage UPS systems with potential-free contacts or serial interfaces (RS-232). to a single UPS in one building to a wide area Network. UPSMAN Configuration - Main Page UPSMAN Event Configuration - Comfortable Overview of all Events and their Corresponding Actions. UPSMAN insert Event Function every Event can be individually programmed with Responses, such as T ext Log Entry, Email/SMS Notification etc.

Description UPSMAN If UPSMAN detects voltage variations, power loss or any other UPS condition, it can respond with a wide variety of ACTIONS to each different EVENT, which for example may shutdown the server or send warnings and emails to connected users. The user can alter the configuration in respects to network messaging, sending of email or SMS, (Remote Console Command) shutdown, etc. More than 12 languages are supported. UPSMAN for Windows P/VISTA Business/2000//2003 Server/2008 Server/Windows 7, Novell NetWare and UNI have an SNMP proxy agent, which translates all UPS data into SNMP format. This allows for NMS software like HP Openview, IBM Netview and others to utilise its own processing tools. Every UPSMAN comes with its own web-server, that allows the monitoring or configuration from remote using any standard web-browser. UPSMAN runs also on less widely spread platforms like DEC VMS/Compaq and APPLE MAC and of course, inside the CS121 Web Adapter. CS122 UPS Status T ext Log File viewed via Web-Browser UPSMON/UPSVIEW monitoring the UPS via Web-Browser remotely Description UPSMON/UPSVIEW UPSVIEW is a graphical Windows client for operating and monitoring the active UPSMAN software connected to an UPS. UPS-Routine schedules can be programmed (e. g. define dates for automatic UPS-tests, shutdown the system at defined dates, etc.) to check the status of the UPS, and execute different programs or create power quality statistics. With UPSVIEW you can evaluate the event protocol (log file) that is permanently updated by UPSMAN. The data communication to the UPSVIEW is achieved via TCP/IP, IP, NetBEUI or SNMP. The integrated Java tool JAVAMON for UPSMON/UPSVIEW and web server/html for the CS121 series are alternative graphical administration interfaces that can be conveniently accessed via the network/internet. UPSMAN on CS121 Web-Browser Configuration/Monitoring Windows UPSMON/UPSVIEW Monitoring a simple Network UPS

Description UNMS II The UNMS is a customisable network management software for the centralized or remote monitoring of UPS, Inverters, Rectifiers, Battery management system BACS and other power management devices. Additionally the system monitors Environmental sensors and alarm contacts like smoke sensors, door contacts, or any other sensor. The UNMS is fully web-based and may be managed from any computer with a web browser in the network. A very special feature is the customisable interface of the UNMS. This allows the user to adjust the graphical look & feel of the software to his installations and makes the use of the product much easier than standardized software interfaces without customisable screens. Separate users setups allow access to the different management levels only for authorized users. The connection between the monitored devices is established through 4 ways (see picture below): A. UNMS Tele-service - Network LAN - this is a connection via TCP/IP through a LAN and/or VPN- Tunnel, a secured internet connection. B. UNMS Tele-service GSM Wireless- this is a wireless GSM/EDGE Network connection through a VPN Tunnel of the DATASERVER portal. C. UNMS Tele-service Email Trap this is a Push Email connection called EmailTrap, transmitting all data through the SMTP Protocol. D. UNMS Tele-assistance Modem This Modem Peer-to-Peer solution is not longer supported after 2012, replaced by the solutions A - C. All 3 modes can work simultaneously so that all devices can be managed by a single UNMS, which is a combination of local and remote monitoring system UNMS II City Country The Systems-Configurator

Description Every UPSMAN includes an Server ("Remote Console Command"). The counterpart is an additional client module, which executes a command on a remote system, similar to the Remote Shell- Program (RSH) known in the UNI world. is used to provide a simultaneous and secure shutdown of several servers and/or workstations on almost any platform. is also capable of relaying messages and commands to remote LAN/WAN clients. Using the specially developed network protocol, is the most successful UPS shutdown solution for networks and available for more than 35 operating systems. With its latest extension is now more flexible and offers more functions, such as: Message transfer via TCP/IP between different operating systems: An alarm message from a Windows network maybe also distributed in UNI and Mac network. This is particular applicable when using SNMP adapters, which normally only respond by sending SNMP traps to an operator. Via 2 a CS121 can now react via Windows network message and UNI -message and notify users. Automated remote maintenance from network computers without user account or login: 2 can execute any program on a remote computer No login required. Graphical configuration interface for all functions, also for UNI and Mac OS (from 10.x) Alive-Check clients may periodically check if the UPSMAN sender is available. group from up to 4 UPS as a parallel redundant system. Client Redundancy Configuration Page Comfortable Shutdown Configurator Diagram Module

Features Available for Windows 9x, NT (INTEL, ALPHA, MIPS), 2K, P, 2003/2008 Server, Netware, Mac OS 9.x and 10.x, 15 UNI versions and Open VMS and IBM OS/2. Monitoring of UPS systems with potential-free contacts or serial interface. Automatic shutdown, Multiserver Shutdown: Unlimited shutdown manager for clients for more than 40 different operating systems. This makes it possible for an UPSMAN Server to notify and shutdown any type of computer in a given network, which can then be used to centralize the administration of large networks while greatly reducing both the amount of organisational work and the amount of consumed network time for communications. Different methods are available for conducting shutdowns and system start ups: 1. Cold-boot (computers are directly cut-off from or connected to the power supply. This option may require a SiteSwitch.) 2. Warm-boot (using operating systems are prompted to shutdown or restart.) 3. Wake on LAN (using data packages other computers in a local network are prompted to startup.) Program execution, messaging, logging etc. of local and remote computers into the network. (Master/Slave via module). Logging of all UPS information and measurement values in CSV, comma separated values, format for MS-Excel, Lotus, GChart Scheduler for time controlled execution of functions, such as battery test, reboot, shutdown etc. Password protection of all UPS remote functions Multiple-start possible to control several UPS from one computer Scheduling of up to four electrical sockets (special UPS types or optional hardware type SS4 required. Configuration and look & feel is identical on all platforms (UNI, Windows, NetWare, VMS, MAC OS) User messages in 12 languages UPSMAN can work with extension modules such as the SensorManager (temperature/humidity and other sensors), RASManager (modem solution), SiteSwitch (power distribution and switching unit), UPS SNMP Watch (software for parallel redundant UPS), HP Openview snap-in, etc. Supports all UPS using RS-232 protocol and contact closure interfaces. Graphic display of input voltage and frequency with min., -max. and average values. Display of the autonomy time and user notification of warnings for low battery, battery error, over temperature, and hardware errors. Log files have a date/time stamp and the UPSMON/UPSVIEW tool bar has a counter for power failures, battery low, system shutdowns and test failures. SMTP compatible system with transmission of information via email, email to SMS or other external services. Integrated SNMP-Agent (RFC 1628 or private MIB) for NetWare, Windows NT/2000, Linux and SUN. Event dependent sending of network messages, logging, email, program execution, etc.

Publication: SielRM/12-14/R0 software - CS121 Web software for Windows NT/2000/2003/P/VISTA CS121 SNMP WEBMANAGER software for Unix/Mac OS systems Network Protocol TCP/IP, NetBEUI, SNMP TCP/IP, FTP TELNET, PPP, SNMP, ARP and others TCP/IP, FTP TELNET, PPP, SNMP, ARP and others Remote UPS monitoring - Shutdown support 2 - Extended remote shutdown function 3 - group/redundancy for up to 4 UPS HP Openview LAN support Network Messaging UNMS - Multi-system remote control Modbus Facility Management capability - - Web browser management Scheduler shutdown History / Event log file Multi-language text log files and network messages Unattended installation available (for automatic script based installations) Password protected remote functions e.g. Emergency off, reboot, tests, etc. UPSMAN/UPSMON/UPSVIEW CS121 Web/Adapter UPS - functions software for Windows NT/2000/2003/P/VISTA - CS121 SNMP WEBMANAGER software for Unix/Mac OS systems UPS-Standard functions/warning: e.g. Battery low power failure overload UPS connection restored System shutdown UPS-Standard functions/warning: e.g. Inverter overload Fuse blown Rectifier mains fault Inverter feeding Battery switch open UPS - send UPS shutdown signal UPS - SNMP redundancy capability (USW software) Graphic display UPSMON / HTML / JAVA Environmental monitoring - Facilitymanagement e.g. SITEMANAGER, SITEMONITOR, SENSOR-MANAGER, SITESWITCH SIEL Energy Systems Ltd SIEL House, Unit E, Draycott Business Park Cam, Gloucestershire. GL11 5DQ www.sielenergy.co.uk email:enquiries@sielenergy.co.uk Telephone: 0845 130 6118 Fax: 01453 899215 The Company s policy is one of continuous development and we reserve the right to alter or amend specifications without notice