Cone Beam Implant Planning Manual



Similar documents
Nobel Clinician - Quick Guide


Ridge Reconstruction for Implant Placement

IMPLANT DENTISTRY EXAM BANK

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

Long-term success of osseointegrated implants

More than a fixed rehabilitation.

Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures

Virtual Implant Placement 2.1. catalog & surgical manual

How To Plan A Dental Implant With A 3D Image Based Program

Flexible dentures an alternate for rigid dentures? Volume 1 Issue 1

Prosthodontist s Perspective

A New Beginning with Dental Implants. A Guide to Understanding Your Treatment Options

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Optimizing Referral Team Collaboration Using Dynamic Visual Communication Software

CLINICAL. Intraoral scanning

Implant Bar Overdenture Utilizing Locator Attachments

IMPLANT CONSENT FORM WHAT ARE DENTAL IMPLANTS?

Dr. Little received his doctorate degree in dentistry from UT Health at San Antonio Dental

SCD Case Study. Treatment Considerations for Implant Rehabilitation

What is a dental implant?

Attachments And Their Use In Removable Partial Denture Fabrication

Ideal treatment of the impaired

There When You Need Them: 10 Principles of Successful RPD Treatment

Modern Tooth Replacement Strategies & Digital Workflow

HEALTH SERVICES POLICY & PROCEDURE MANUAL. SUBJECT: Types of Dental Treatments Provided EFFECTIVE DATE: July 2014 SUPERCEDES DATE: January 2014

What Dental Implants Can Do For You!

Full Crown Module: Learner Level 1

VOL. XX, NO. X. Dr. Leo Malin Erases Challenges of Implant Dentistry

Luigi Vito Stefanelli,D.Eng.,DDS

CHAPTER 12 SURVEY LINES. portion of the tooth is undercut to the path of placement of the denture. DEFINITIONS

ANGEL DENTAL CARE Implant Consent

DENTAL Cone beam 3D X-RAY SYSTEM with

DENT IMPLANT restoring qualit S: of LIfE

While the prosthetic rehabilitation of

CDT 2015 Code Change Summary New codes effective 1/1/2015

How To Use Nobelbiocare'S Integrated Treatment Workflow

Osseo-integrated Dental Implant Policy and Guidelines

ATLANTIS abutments as individual as your patients

PREPARATION OF MOUTH FOR REMOVABLE PARTIAL DENTURES Dr. Mazen kanout

PATIENT INFORM CONSENT for IMPLANT RESTORATION Rev

Understanding Dental Implants

Implants in your Laboratory: Abutment Design

2016 Buy Up Dental Care Plan Procedure List

Abutment fracture in a bridge supported by natural teeth and implants

Full Mouth Restoration with Screw-Retained Zirconia Bridges

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments

General Dentist Fees

Humana Health Plans of Florida. Important:

Page 1 of 10 BDS FINAL PROFESSIONAL EXAMINATION 2007 Prosthodontics (MCQs) Model Paper SECTION I

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

Accelerated Patient Rehabilitation

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

Renaissance of One-Piece Implants

Full Denture System. Full denture prosthetics for dental technicians customised, precise, aesthetic

Oftentimes, as implant surgeons, we are

Don t Let Life Pass You By Because Of Oral Bone Loss

York Region Ontario Works. Schedule of Denture Services and Fees. February 2011

Dentalworkers JOB DESCRIPTIONS Great Team Members make your Office function!

ADA Insurance Codes for Laboratory Procedures:

ONTARIO WORKS ADULT. Emergency Denture Services. Denturist Fee Schedule. Simcoe County

INTRODUCTION TO OSTEO-TI IMPLANTS; A NURSES MANUAL

procedures & products NOBELESTHETICS including Procera

Digital impression solutions. 3M True Definition Scanner. Precise. impressions. in a jiffy

Restoring quality to life. Dental implants. A naturally better solution. Patient Education

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

In Class IV arch: Fulcrum line passes through two abutments adjacent to single edentulous space.

Changes in the Jaw Bones, Teeth and Face after Tooth Loss

Job Ready Assessment Blueprint. Dental Assisting. Test Code: 4126 / Version: 01. Copyright All Rights Reserved.

The Most Frequently Asked Questions About Dental Implants... A Consumer s Guide to Understanding Implant Treatment

Dental Implants. Change Your Life & Smile with. Kingston Kitchener Newmarket Oshawa Scarborough Toronto Waterloo

Veraviewepocs 3D R100 & F40

Procedures & Products Powered by Procera. All-on-4

FABRICATING CUSTOM ABUTMENTS

Dental Implants - the tooth replacement solution

Summary. DWOS New features. Version 1.2. May 08, Summary 1. Latest Additions 3. Orthodontic Archiving 3

Veraviewepocs 3D R100 & F40

Navigator System For CT Guided Surgery Manual

Cone Beam Imaging Why all the Fuss about the X-ray Dose? D.A. Miles BA, DDS, MS, FRCD(C) Dip. ABOM, Dip. ABOMR. Introduction

DENTAL IMPLANT THERAPY

BEST DENTAL ASSOCIATES / DRSTONEDDS.COM THE DENTAL IMPLANT GUIDE

MEDICAID DENTAL PROGRAMS CODING, POLICY AND RELATED FEE REVISION INFORMATION

Tooth Replacement Options

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.

DENTAL FOR EVERYONE SUMMARY OF BENEFITS, LIMITATIONS AND EXCLUSIONS

MEDICAL TECHNOLOGY IN IMPRESSIVE 3D

Procedures & Products. NobelEsthetics

Teeth and Dental Implants: When to save, and when to extract.

ABSTRACT INTRODUCTION. Facial Esthetics. Dental Esthetics

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

Restorative Manual Impression Transfer System

Removable Partial Dentures 101 Back to the Basics. Luther A. Ison, CDT University of Minnesota School of Dentistry

More to feel good about. Baltimore City Public Schools Dental Options

Implant Parts. A Radford Heath Guide 1

CAD/CAM technology supporting successful implant therapy

Telescopic Denture A Treatment Modality for Minimizing the Conventional Removable Complete Denture Problems: A Case Report

OVERVIEW The MetLife Dental Plan for Retirees

Final Result 1 year later. Patient Case 19. Preoperative: Main Complaint:

Transcription:

Cone Beam Implant Planning Manual (Everything you want to know about CBCT planning) Page 2 Overview & Guide Selection Criteria Page 3 Scan Appliance basics When are they required? Page 4 Scan Appliance Indications and protocols Page 5 Scan Appliance Fabrication Instructions Page 6 Scan Appliance Converting an Existing Denture Page 7 NO Scan Appliance Technique Page 8 CT Scan Process General instructions Page 9 Capturing the CT Page 10 Scan Appliance Immediate extraction technique Page 11 Data Export and Upload Page 12 Provisional Restorations & Contact Information

Page 2 2 Page Overview of Dental Implant Planning Guide Selection Criteria Implant surgical guides using Cone Beam Computed Tomography is the most advanced process of predictably planning dental implant placement. ROE Dental Laboratory s Dental Implant Planning Service is a nationally recognized all inclusive, turn key solution to supporting dentists in surgical guidance. We offer treatment planning, diagnostic work up and evaluation, CBCT technical support, live on line meetings, surgical guides, surgical reports, and final restorations. By selecting ROE to support your practice, you chose an experienced team that has completed thousands of successful cases. Significant advancements in cone beam planned surgical guides during the past few years have allowed surgical guidance to be more affordable and accessible. With our service you can create surgical guides for any type of treatment from single unit placement to immediate load All on 4. We accommodate all implant systems and provide surgical guides that accommodate your existing armamentarium and all guided surgical kits. This manual will lead you through the CT process, beginning with guide choice. Choose guide type The first step in the process is to choose the type of surgical guide and the planning software to be utilized. There are four basic designs from which to choose. All planning software systems can accommodate tooth or tissue supported guides, however bone supported guides placed on a fully flapped ridge can only be created with two of our software choices, SimPlant and BlueSkyPlan. Tooth Supported partially edentulous Tissue Supported edentulous Bone Anchored/Tissue Supported w/ stabilization pins Bone Supported/Bone Anchored fully flapped Choose the software Once the guide type is selected you will need to decide which software is the best choice for your particular case. Cost, return time, guided surgery kit compatibility, and case sophistication are all factors to consider. The chart below lists the related features of the each of our four software choices. Cost Return Time after Case Plan is Approved (days) Guided Surgery Kit Compatibility Software Sophistication $$$ 7 10 Excellent Excellent $ 3 Limited Good $$ 3 Good Good $$$ 7 Only Nobel Good CT Planning Questions Call 800 228 6663

Page 3 3 Page Guide Selection Criteria continued & Scan Appliance Basics The choice of software affects the materials and steps involved in the process. The chart below provides an overview of the requirements as they relate to the software selected. Please note that two of the systems, SimPlant and BlueSkyBio, allow us to use the more efficient and cost effective no scan appliance technique. This details of this technique are explained on page 8. Select a software Requirements > Accurate models or impressions Diagnostic tooth position information Scan appliance DICOM 3 data of patient DICOM 3 data of patient w/ scan app. DICOM 3 Data of Appliance Alone Scan Appliance Technique X X X X X Go to Page 4 for instructions X X X X X X X X X X X X X X X No Scan Appliance Technique Go to Page 7 for instructions X X X X X X What is a scan appliance and when is it required? A scan appliance (a.k.a. radiographic guide) is a rigid acrylic appliance which fits over the existing teeth and tissue. It represents the teeth to be restored and includes radiopaque markers for registering the appliance in the CT. The proper fabrication of the scan appliance is the critical first step CT planning. In most situations the final surgical guide is a digital duplicate of the scan appliance, so design and fit are crucial. To ensure surgical guides fit at the time of surgery, final impressions and master casts must be precise. As mentioned above, proper design of the scan appliance is essential. Material thickness, proper placement of radiopaque markers, density of material, and adequate tooth and tissue coverage for guide sleeves are all important. Scan appliance protocols are available through our website www.dentalimplantplanning.com, however it is our experience that better outcomes are achieved when our they are fabricated through our laboratory. Turnaround time is 4 laboratory days. Scan appliances are not always needed. When a case involves 5 teeth or less, and there are minimal metal based restorations present, a scan appliance can be avoided, lowering the cost and simplifying the process. It is important to note that NobelGuide and ident always require scan appliances.

Page 4 4 Page Scan Appliance Scan Appliance Technique Indications & Protocols: When is a Scan Appliance required? Reconstructive cases For surgeries involving the restoration of significant dentition, particularly in the anterior segment, it is beneficial to have the tooth position verified intraorally with a scan appliance. Edentulous cases Without a scan appliance, implant position may not coordinate with final tooth position and may compromise the definitive restoration. Avoiding excessive scatter Metal restorations cause scatter. Excessive scatter requires the use of a scan appliance. The amount of scatter can be determined from a preliminary CT or existing radiograph. Software choices BlueSkyPlan, SimPlant, ident, NobelGuide What are the steps required when a Scan Appliance will be utilized? Step 1. Restorative Doctor: Provide quality master casts, full arch maxillary and mandibular silicone impressions, a bite registration, study model and completed CT Order Form. Step 2. ROE Dental Laboratory: Create a diagnostic wax up of the proposed final tooth position. Once approved a CT scan appliance is fabricated. If the patient has an existing denture with desired tooth position, it can be used as the scan appliance (see page 10). If the denture is ill fitting a hard reline is necessary. Step 3. Restorative Doctor: Try in the scan appliance to verify the fit. Once approved scan the patient following the specific protocol. If the fit is not ideal, adjust accordingly or capture new impressions and remake the scan appliance. Step 4. Imaging Location: Record CT scan a specific protocol must be followed for each planning software. If you have any concerns about this process, we suggest calling ROE while the patient is still in the office to confirm the accuracy of the scan. Upload the DICOM to ROE through www.dentalimplantplanning.com. Step 5. ROE Dental Laboratory: Preplan case using planning software ensuring implant locations meet surgical and restorative requirements. Step 6. Specialist, restorative dentist, and laboratory: Attend a live, interactive online meeting (go.mikogo.com) to modify and approve the surgical plan for guide fabrication. The placing doctor completes and returns the signed CT Order Form, which contains the drill sequence. Step 7. ROE Dental Laboratory: Create the surgical guide and drilling report.

Page 5 5 Page Scan Appliance Fabrication Scan Appliance Fabrication Instructions: Impression Material & Models Whether you make the radiographic guide yourself or using the laboratory, the impression is the critical first step in the process. This will ultimately affect the overall accuracy of the surgical guide that is created. We recommend VPS or similar material to be used to take the impression. You must take an impression that captures the peripheral borders and full palate on the maxilla and the peripheral borders and retro molar pad areas on the mandible. The vestibule must be clear and undistorted. The entire impression should be free of pulls and bubbles. If the model is not accurate the fit of the radiographic guide will be compromised. Guide Material The radiographic guide should be fabricated from clear orthodontic acrylic. Do not use vacuform or any other non rigid material. These material are too thin and do not exhibit the proper density for scanning. Making the Guide A diagnostic wax up is used to fabricate the radiographic guide. The crowns should be distinctly represented on the facial/buccal and occlusal aspects of the guide. Facially, the crowns of the guide adjacent to existing teeth should adjoin the guide via a diagonal span of acrylic. The guide should cover the occlusal surface of the full arch. The guide should extend over gums on the lingual/palatal side. The flange should be at least 3 mm thick. The replacement teeth on the guide should touch tissue in edentulous areas. The guide should not have any gaps between the gingiva and the guide. It is important to be aware that the surgical guide will be an exact duplicate of the radiographic guide. The only changes in shape will be the tunnels made by the software for the implant sites. Radiopaque Markers The appliance should have eight, 1.5mm round gutta percha radiopaque markers placed into the appliance (#5 bur). These markers are utilized in the data merging process following the CT scan. We suggest six randomly placed on the palate and two within the labial flanges. To eliminate the possible effects of scatter, markers should be placed 10mm away from any metal restorations. Proper Fit Because the surgical guide will be an exact duplicate of the radiographic guide, the guide should fit securely on the patient s teeth and/or tissue. If the guide does not fit securely, the guide must be remade. The guide does not need to have perfectly balanced occlusion. Cotton rolls or a radiolucent bite must be used to separate the arches during the scan. CT Planning Questions Call 800 228 6663

Page 6 6 Page Scan Appliance Converting an Existing Denture Duplicating an Existing Prosthesis The patient s existing denture, or duplicate of the denture, may be used as the scan appliance 1. Six gutta percha markers are placed on the lingual/palatal side of the prosthesis and two within the buccal flanges. If the denture does not fit properly it is recommended that a hard acrylic reline is performed. This will ensure an ideal fit of the surgical guide. If you or the patient prefers not to add the markers to the patient s current denture, a putty flask of the denture can be sent to us for duplication. A simple flasking technique is shown below. This minimizes in office work and the need for the patient to spend time without their denture. 1 unless a SimPlant bone supported guide is to be used. A choice is available between a special dual density scan appliance or the noscan appliance technique the latter is inadvisable on edentulous patients as tooth position will not be validated.

Page 7 7 Page The NO Scan Appliance Technique NO Scan Appliance Technique Indications & Protocols: When can the No Scan Appliance Technique be utilized? Non edentulous treatment plans that replace five or less teeth per arch are candidates for the no scan appliance technique. A contraindication to this technique is if a patient has multiple metal based restorations in the arch being restored metal creates scatter rendering a difficult or impossible registration. The no scan appliance technique uses the virtual placement of teeth, or a scan of a functional diagnostic wax up, to determine tooth position for virtual surgical planning. The scanned model image is superimposed over the conebeam data rendering accurate hard and soft tissue surfaces in the software from which your clinical decisions can be made. Currently this technique is only available with BlueskyPlan and SimPlant. Software choices BlueSkyPlan & SimPlant What are the steps required if the No Scan Appliance protocol is used? Step 1. Restorative doctor or specialist: Provide master casts or full arch maxillary and mandibular silicone impressions, bite registration, study model, and completed CT Order Form. Step 4. Imaging Location: Record CT scan a specific protocol must be followed for each planning software. If you have any concerns about this process, we suggest calling ROE while the patient is still in the office to confirm the accuracy of the scan. Upload the DICOM to ROE through www.dentalimplantplanning.com. Step 3. ROE Dental Laboratory: Preplan case using planning software ensuring implant locations meet surgical and restorative requirements. Step 4. Specialist, restorative dentist, and laboratory: Attend a live interactive online meeting (go.mikogo.com) to modify and approve the surgical plan for guide fabrication. The placing doctor completes and returns the CT Order Form which contains the drill sequence and case approval to ROE. Step 5. ROE Dental Laboratory: Create the surgical guide and drilling report. CT Planning Questions Call 800 228 6663

Page 8 8 Page CT Scan Process CT Scan: General Instructions General Overview: In order to fabricate a CBCT based surgical guide we require uncompressed DICOM3 data from a Cone Beam CT or Medical CT. The records and type of scan we require depend upon the software and the technique to be utilized. The cone beam settings and scanning instructions mostly remain consistent regardless of the type of scan (variances in the box to the right). The models or impressions should be of high quality because the accuracy of the surgery depends upon these initial records. The restorative tooth position must be determined using an existing appliance a denture tooth setup, or a virtual or diagnostic wax up. This should be approved by the restoring dentist and/or the patient. In order to begin the diagnostic process complete our CT Order Form with explicit instructions on the restorative goals and requirements. General scanning instructions: Set the table height so that the mandible or maxilla is centered in the scan field. All slices must have the same field of view and table height. Scanning with a field of view that is too large can compromise the resolution of the reformatted images. Scanning with a field of view that is too small can cause the jaw to not fit in all the axial images. Not overlapping the axial slices can reduce the quality of the reformatted images. Scan all slices of the study in the same direction. Scan with the same slice spacing; the slice spacing must be less than or equal to the slice thickness. The slice thickness should not be larger than 1 mm. All of the remaining teeth/scan prosthesis should be completely visible in the images up to the occlusal plane. Cone Beam Settings General 0.4 Voxel Scan Time 20 Seconds FOV 140 and 170 mm Stitched scans on small FOV Matrix 512 x 512 System Specific Instruction Kodak System = Scan Appliance should be scanned at KV 80 Ma 2 Galileos System = Scan Appliance must be scanned inside of the special Sirona aluminum scan cylinder Part # 6299759 using settings: 42 MAS w/o Hi Contrast VO 1 PlanMeca = Scan Appliance should be scanned at KV 70 Ma 10 The gantry tilt should be 0 degrees. Reconstruction of the images: Use a proper image reconstruction algorithm to get sharp, reformatted images to clearly locate internal structures such as the alveolar nerve. Use the sharpest reconstruction algorithm available (usually described as a bone or high resolution algorithm). Only axial images are required. No dental reformatting of the images is needed.

9 Page Page 9 Capturing the CT CT Scan: Capturing the CT When a scan appliance will be used, two scans are required, one of the patient with the appliance seated and one of the scan appliance alone. If surgical guides will be made on both arches, each arch should be scanned separately to prevent the fiducial markers from interfering with one another. If the patient is edentulous, to stabilize the appliance and prevent movement, separate the arches with cotton rolls. Preparation of the patient Remove any non fixed metal dentures or prosthesis in addition to any jewelry that might interfere with the region to be scanned. Non metal dentures may be worn during the scanning. If the patient has a scan prosthesis (radiographic template), it should be worn. Make the patient comfortable and instruct him/her not to move during the procedure. Normal breathing is acceptable, but any other movement, such as tilting and turning the head can cause motion artifacts that compromise the reformatted images, requiring the patient to be rescanned. Aligning the patient For correct alignment, the transaxial CT slice plane should be parallel to the occlusal plane of the upper jaw (see figure 2). The gantry tilt is 0. Ideally, you should determine the occlusal plane using the patient s scan prosthesis. If the patient does not have a scan prosthesis, use the existing teeth to align the patient. Stabilize the relationship of the jaws during the scan. Scan patient with arches opened using cotton rolls or a bite registration index (figure 2). Scanning instructions Figure 1 Bite registration separating the arches Positioning for the mandible Position the first slice just below the inferior border of the mandible. Position the last slice just above the lower teeth, or in the absence of teeth, set the last slice just above the superior border of the mandibular ridge. If the patient is wearing a scan prosthesis, position the last slice just above the prosthesis. It is critical you include the entire prosthesis in the scanned study and that no teeth or prosthesis are visible in the last slice. Positioning for the maxilla Position the first slice just below the upper teeth. In the patient is edentulous, and is wearing a scan prosthesis, position the first slice just below the prosthesis. It is critical you include the entire prosthesis in the scanned study. Position the last slice 4 to 5 mm above the floor of the nasal cavity. If planning for zygoma implants, the last slice must be positioned in the middle of the orbita, called the sutura. Positioning and Scanning the Scan Appliance Separately (without patient) The scan appliance should be placed on Styrofoam (Polystyrene), foam, or on the guide holder specifically designed for this purpose and supplied by the Cone Beam manufacturer (figure 3). The packaging foam included in ROE Dental Laboratory case boxes works well. The appliance should be positioned in the same orientation as scanned in the patient s mouth. Figure 2 Patient prepared for the CT scan Figure 3 Styrofoam platform separating the appliance from the chin rest

10 Page Page 10 CT Scan Process Immediate Extraction Technique Instructions for using CT Scan Appliance when the case will involve extractions at the time of implant placement: When a scan appliance is required and the case involves the immediate extraction of teeth at the time of surgery, a modified technique must be utilized. ROE has developed a special scan appliance that reduces the traditional two appointment scan to just one. The following 6 steps explain the process. 1. Separate the primary scan appliance from any removable section (s) attached to the appliance. The separate sections will represent the areas involving the immediate extraction of teeth at the time of implant placement. Figure 4 2. Seat the primary scan appliance containing the gutta percha fiducials in the patient s mouth, without the separate sections. Separate the appliance from the opposing teeth using two cotton rolls. 3. Request that the patient stay motionless and follow the manufacturer s instructions to capture the 1 st of 2 CBCT images, as previously discussed. Figure 4 4. Remove the appliance from the patient s mouth and glue (included) the removable scan appliance section(s) back to the primary scan appliance (patient does not need to be present henceforth). Figure 5 5. After the glued sections have completely dried, scan the appliance alone as previously discussed. The appliance should not be placed directly on the chin rest. It must be placed on styrofoam or a foam block, such as the padding inside a ROE shipping box. The appliance should be oriented within the table in the same position as the patient scan. Figure 5 CT Planning Questions Call 800 228 6663

11 Page Page 11 Data Export and Upload Data Export & Upload: 1. Export the data from within your CT scanner s software to an area of your computer that is accessible. We suggest that a folder is created on the desktop with individual folders inside one for each patient with sub folders for the scan(s) (Figure 6). 2. Export the patient s uncompressed DICOM 3 multi file volume to this folder (named patient ). Do not export viewers, icat visions, single file, compressed, or DICOMDIR. These file types are not usable. 3. Repeat the process above for the dataset that contains the scan of the radiographic appliance only (folder named appliance ), if the scan appliance protocol was used. 4. When both arches are being planned for implants, scan them separately and save in them in separate labeled folders. 5. Place all folders into one master folder with the patient s name. 6. Zip the master folder by right clicking it, scroll down and click Send To Compressed (Zipped) Folder (figure 7). This will create a Zipped folder (looks like the original with a zipper on the front). It will be located in the same area as the original folder (figure 3). 7. Visit ROE s website www.dentalimplantplanning.com. Click the Upload button, and follow the instructions. Click Browse, search for the zipped folder (should be on your desktop in the folder you created). Double click on this folder and click Send on the web page. Figure 6 A sample of the file structure that should be saved and uploaded to ROE. Figure 7 To upload your DICOM, the containing folder must be zipped. Right click on the folder and curser down to Send to, curser to the right and click Compressed (zipped) folder. A new folder will be created next to the original folder. When you browse from our web site www.dentalimplantplanning.com you will double click on this zipped folder to attach.

12 Page Page 12 Immediate Implant Provisionalization Immediate Implant Provisionalization CBCT Guided surgery allows for immediate provisionalization of implants to be accomplished with increased accuracy and efficiency. In most situations, once a surgical guide is created, ROE Dental Laboratory can reverse engineer analog placement into the model with the surgical guide and surgical report. We work with all kits that offer a laboratory component for accurate provisionals. However, an implant model can be created in almost any situation for abutment selection and provisional fabrication offering varying levels of accuracy. Please contact us to discuss the specifics of your case. Contact Information Mailing Address ROE Dental Laboratory 9565 Midwest Ave. Garfield Hts., OH 44125 World Wide Web ROE Dental Laboratory www.roedentallab.com Full Service dental laboratory Dental Implant Planning www.dentalimplantplanning.com (www.roeplan.com) Implant planning site to support CBCT Telephone 800 228 6663 toll free 216 663 2233 local 216 663 2237 facsimile Email info@roedentallab.com Jason@roedentallab.com joe@roedentallab.com Jason Carruth ext 313 Tech Support Joe Ambrose CDT ext 303 Tech Support / on line planning