SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

SECTION STORM DRAIN SYSTEM

Beacon Hill Sewer District Standard Specifications

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

SECTION POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

SECTION SITE PREPARATION

SECTION STORM DRAINAGE SYSTEM

DIVISION 4300 STORM DRAINAGE

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

FY08 SEWER POINT REPAIRS BID TABULATION

Section SEWER PIPE INSTALLATION AND TESTING

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

Section 2100-Trenching and Tunneling

CHAPTER 6 - SANITARY SEWER

SECTION PRECAST CONCRETE UTILITY STRUCTURES

Town House Center Highway North Huntingdon, PA 15642

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

SECTION STORM DRAINAGE TABLE OF CONTENTS

San Antonio Water System Standard Specifications for Construction ITEM NO POINT REPAIRS AND OBSTRUCTION REMOVALS

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

CW GRAVITY SEWERS TABLE OF CONTENTS

Wastewater Capital Projects Management Standard Construction Specification

SECTION FACILITY STORM DRAINAGE PIPING

WATER SERVICE 2

Bethel Township Municipal Authority (BTMA) RESIDENTIAL SEWER CONNECTION MANUAL

SECTION SEWERAGE AND DRAINAGE PART 1 - GENERAL 1.01 RELATED DOCUMENTS

City of Virginia Beach Public Utilities HRPDC Regional Construction Standards, 5 TH Edition Amendments May 19, 2014

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

SECTION ABANDONMENT OF SEWER MAINS

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

STANDARD SPECIFICATIONS SECTION INSTALLATION OF GRAVITY SEWER PIPELINES. 1. Trenching, Backfilling and Compacting: 02223

INSTALLATION OF INSITUFORM LINER

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

SECTION 724 PIPE CULVERTS

550 PIPE CULVERTS, SEWERS AND DRAINS

Section 402. STORM SEWERS

TABLE OF CONTENTS. Manhole, Frame, and Cover Installation (includes Drop Manhole) Additional Manhole Depth

WILDCAT CANYON ROAD SPECIFICATION NO SLIDE REPAIR BIDDER'S PROPOSAL (continued)

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 21

The Manitoba Water Services Board SECTION Standard Construction Specifications PIPE EXCAVATION, BEDDING AND BACKFILL Page 1 of 11

SECTION GRAVITY SANITARY SEWERS

900 SEWERAGE WORK ITEM PIPE SEWERS COMPLETE IN PLACE

PUBLIC WORKS DESIGN, SPECIFICATIONS & PROCEDURES MANUAL LINEAR INFRASTRUCTURE

Sewer Line Rehabilitation

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

Special Specification 7021 Water Main and Sewer Line Replacements

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

A. This Section includes the following for soil, waste, and vent piping inside the building:

53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:

Sewage Compliance Form Instructions

ARTICLE VI (ALTERNATE) STANDARD SPECIFICATIONS. for (PVC) SANITARY SEWER MAIN CONSTRUCTION

SECTION 9.02 BUILDING SUBSURFACE DRAINS (PERIMETER, ETC.)

Close-Out Documents... 9

Specifications for Residential Property Owners Connection to New Public Sewer

SANITARY SEWER SERVICE CONNECTION INSTRUCTIONS

SECTION 7- STORM SEWER

SECTION POLYVINYL CHLORIDE (PVC) PIPE

CITY OF BEVERLY RULES AND REGULATIONS - SEWER SYSTEM TESTING. General

SECTION BUILDING SEWERS. B. Connection of building sanitary drainage system to municipal sewers.

CHAPTER 17: STORM SEWER STANDARDS Introduction Administration Standards 17.1

C. Section TESTING LABORATORY SERVICE.

SECTION 6A STORM DRAIN DESIGN Mar S E C T I O N 6A STORM DRAIN - DESIGN

CHAPTER 11 STORM DRAINAGE

SEWER BACK UP PREVENTION PILOT PROGRAM

Let Us Give Utilities the Respect that they Deserve.

DESCRIPTION OF WORK:

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

ARLINGTON HEIGHTS MUNICIPAL CODE CHAPTER 22 SEWERS

Exhibit A. Rules and Regulations for House Connections and Sewer Extensions

SECTION POLYVINYL CHLORIDE (PVC) PIPE

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

APPLICATION FOR DEMOLITION & RIGHT-OF OF-WAY PERMIT

APPENDIX C INLETS. The application and types of storm drainage inlets are presented in detail in this Appendix.

Storm Sewer Trenchless Upgrade Alternatives and Recommendations

SECTION ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

San Antonio Water System Standard Specifications for Construction ITEM 866 SEWER MAIN TELEVISION INSPECTION

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development

City of West Linn Public Works Standard Construction Specifications. Table of Contents

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER

Section 2 Specification 2.18 Concrete and/or Corrugated Steel Storm Sewer TABLE OF CONTENTS

SECTION G SEWERS (STORM, SANITARY AND FDC)

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

Transcription:

LS 2540 SEWER LATERALS AND INSPECTION TEES A. Summary B. Submittals C. Site Information D. Sewer Pipe and Fittings E. Lateral Locations F. Lateral Installation G. Inspection Tee Installation H. Removal and Repair of Surface Items I. Water System Repairs J. Final Cleaning and Documentation K. Method of Measurement L. Basis of Payment A. Summary This section includes sanitary and storm sewerage system lateral piping and appurtenances. B. Submittals All product data for pipe and appurtenances in accordance with the General Conditions. C. Site Information The Contractor is responsible for performing a site survey sufficient to perform the specified work., including research public utility records and physically locate and verify existing utility locations prior to beginning construction of proposed sewer(s). Verify that sanitary and storm sewerage system piping may be installed in compliance with original design and referenced standards. Locate existing utility, storm and sanitary sewerage system piping and structures that are to be crossed, connected, abandoned and/or closed. D. Sewer Pipe and Fittings General: All pipe and appurtenances shall as specified in LS 2530 and LS 2630, expect as modified herein. Provide fittings for jointing sewer pipe per CMS 706.11 (concrete pipe) or CMS 706.12 (vitrified clay pipe). Sleeves: ASTM F 477, elastomeric seal for plastic pipe. Sleeves for dissimilar or other pipe materials shall be compatible with pipe materials being joined. LS 2540-1

Bands: Stainless steel, one at each pipe insert. Couplings: Rubber or elastomeric compression gasket, made to match pipe inside diameter or hub, and adjoining pipe outside diameter. Gaskets: ASTM F 477, elastomeric seal for plastic pipe. Gaskets for dissimilar or other pipe materials shall be compatible with pipe materials being joined. Inspection Tee's: Riser shall be six inch (6 ) diameter PVC sewer pipe meeting these specifications with six inch (6 ) x six inch (6 ) long - sweep tee connection to the lateral and a threaded coupling with brass cap at the top. E. Lateral Location The Contractor shall determine the location of all existing storm and sanitary laterals within the project area or determine to the satisfaction of the City that such laterals do not exist. The following items shall be executed prior to all other construction work: Obtain owner permission, enter the property, locate sanitary clean out plugs and storm inlets, open same, introduce a radio or sonic transmitter that can be extended through the lateral to the sewer main, trace the path of the laterals on the ground surface and measure the location of the laterals as documentation. Transmitter equipment must be able to negotiate tight bends. Obtain Owner permission, enter the property, introduce sewer dye into all service connections such as soil stacks, floor drains, downspouts and yard drains to confirm sewer main connections. Clogged laterals: If a lateral is clogged to the extent that location and television equipment can not be used to trace the pipe, the Contractor shall clean in the presence of the Engineer or Inspector and then perform documentation work. Locate each existing inspection tee, uncover, open it, document its condition and use it to access the attached lateral. All items damaged during investigation work shall be repaired and restored to functional condition as acceptable to the owner and the City. All information shall be copied to the City prior to project or task completion. F. Lateral Installation Missing lateral(s) and inspection tee(s) shall be installed complete from the sewer main to the upstream side of the inspection tee. The Contractor shall connect the new lateral to the property lateral. If no property lateral exists, the new lateral shall be capped with a removable, secure pipe cap. Invert elevation of the new inspection tee shall be field determined by the Engineer. LS 2540-2

Excavation shall be as specified in CMS Item 603. Contractor shall determine grade for trench bottom to maintain a minimum 0.4% lateral invert slope from the property lateral to the sewer main in the street. Contractor shall propose lateral configuration to the Engineer and receive confirmation or design changes prior to installation and backfill. Installation, General Install piping from either end, true to approved slope and alignment with unbroken continuity of invert to sewer main. Lateral connections to deep sewer mains can utilize 45 degree elbows and steep pipe slopes to minimize lateral depths. Place bell ends of piping facing upstream. Install gaskets, seals, sleeves and couplings in accordance with manufacturer s recommendations for use of lubricants, cements and other installation requirements. Only wye fittings shall be used to connect laterals to main sewer unless another method proposed by the Contractor receives approved from the Engineer. Remove unstable, soft and unsuitable materials at the surface upon which pipes are to be laid and backfill with No. 57 limestone to required elevation. No property lateral shall be left unconnected to the main sewer over night. If needed, the Contractor shall provide temporary connections at his or her expense. G. Inspection Tee Installation The final location of the inspection tee(s) shall be approved by the City and as necessary to avoid extreme grades, retaining walls, trees, landscaping or other major obstructions. In general, inspection tee's shall be installed within 24 inches of the right of way line on private property. The riser(s) shall be vertical and plumb. In lawn areas, the finished elevation of the brass cap shall be six (6) inches below the prevailing surrounding grade. In pavement areas, the finished elevation of the brass cap shall be flush with the surrounding pavement. H. Removal of Repair of Surface Items Pavement and existing curbs shall be diamond saw cut where required. Curbs shall be restored according to ODOT Type 6 design, modified for curb cuts as required. Underdrains shall be restored across work areas according to CMS Item 605. LS 2540-3

Existing drive aprons and adjacent sidewalks shall be removed completely or as directed by the Engineer only if required. Drive aprons shall be restored with four (4 ) inches CMS 304 limestone and six (6 ) inches concrete (residential) or eight (8 ) inches concrete (commercial), as specified. Existing walks shall be diamond saw cut and/or removed at the closest existing joints. Walks shall be restored with three (3 ) inches #57 limestone and four (4 ) inches concrete as specified finished with the Lakewood standard "picture frame" tooling and broom finish. Grassed areas shall be restored in accordance with LS 659. Brick tree lawn areas shall be restored in kind. The impact of construction on private property shall be kept to an absolute minimum. Plant materials other than grass shall be carefully removed with enough root and soil and stored in such a way as to ensure survival during the stockpile period. The plant stockpile shall be watered daily. Subject plant materials that are destroyed or do not survive one month past the construction period shall be replaced by the Contractor in kind or as acceptable to the property owner and City at no cost to the City. Watering following re-planting shall be as required in LS 659, above. All rocks or other structures removed shall be re-installed in kind. I. Water System Repairs The Contractor at his or her option can work around the existing copper supply lines and curb stops or remove and replace them. Supply line replacement shall include a new copper tube from the corporation tap to the curb stop and connection to the property side supply line. The cost for all work involving an existing copper supply line shall be included within the tabulated items at no additional cost to the City. Under no circumstances shall a property be without water service for more than two (2) hours. The Division of Water shall be contacted to request a temporary house to house connection to accommodate water service interruptions of between two (2) hours and 24 hours. Under no circumstances shall a property be on a temporary water supply for more than 24 hours. All existing in-ground watering systems damaged by construction shall be repaired inkind. J. Final Cleaning and Documentation The Contractor shall provide documentation that all laterals are clear of obstructions televising the lateral(s) and sewer main(s) in the presence of the Engineer or Inspector. Any video recordings shall be copied and turned over to the City. LS 2540-4

K. Method of Measurement The City of Lakewood will measure and pay for Sewer Laterals including Inspection Tees by the actual number of laterals installed. Payment for these items shall be considered full compensation for all labor and material. The Contractor should anticipate that the lateral pipe will be approximately 25 degrees off the perpendicular. The City of Lakewood will measure and pay for six inch (6 ) to eight inch (8 ) sewer lateral connections and couplings by the actual length of pipe and fittings installed. L. Basis of Payment The City will pay for accepted quantities at the contract unit prices as follows: Item Unit Description LS 2540 EACH Storm Sewer Lateral LS 2540 EACH Sanitary Sewer Lateral LS 2540 LF 6 8 Sewer Lateral Connections and Couplings END OF SECTION LS 2540 LS 2540-5