UNDERGROUND INFRASTRUCTURE SPECIALISTS TABLE OF CONTENTS



Similar documents
PRODUCT CATALOGUE. for. SMARTPHONE / WEBSITE / DIGITAL EDITION / BOOK / ipad / GPS

Storm Sewer Trenchless Upgrade Alternatives and Recommendations

ATTACHMENT 3: SPECIFICATION FOR SEWER CLEANING

SPECIFICATIONS FOR SEWER PIPE AND LINING INSERTION - TRENCHLESS; GENERAL GUIDELINES (As Provided by NASSCO)

CCTV INSPECTION OF SEWER LINES. A. Section Sanitary Gravity Sewer Lines. B. Section Sanitary Gravity Sewer Line Testing

PORTLAND BES ADVANCES IN SEWER MAINTENANCE AND REPAIRS BY OPERATING MULTIPLE CIPP CREWS.

SECTION CLEANING AND CLOSED CIRCUIT TELEVISION (CCTV) INSPECTION OF SEWER PIPE

REPAIRS TO DAMAGED SEWERS

1.3.2 Method of construction and restoration of existing water service connections. This shall include:

SEWER CLEANING, INSPECTION AND ASSESSMENT

Specification for Pipe Bursting Gravity Sewer Mains with HDPE Pipe

Pipe Bursting. Case Study at Zeeland, MI Collections Seminar September 6, Presentation Agenda. What is Pipe Bursting? What is Pipe Bursting?

STANDARD SPECIFICATIONS SECTION CLOSED CIRCUIT TELEVISION INSPECTION OF SEWER MAINS, MANHOLES AND LATERALS

Mainline Pipe Rehabilitation Using Cured-in-Place Pipe (CIPP) & Folded Pipe Technology

San Antonio Water System Standard Specifications for Construction ITEM NO POINT REPAIRS AND OBSTRUCTION REMOVALS

PROVIDING THE SAFE CHOICE FOR UNDERGROUND PIPE RENEWAL, INTEGRITY MANAGEMENT AND ASSET RELIABILITY

Waste Collection Systems

REHABILITATION OF UNDERGROUND SEWER LATERAL PIPES WITH CURED-IN-PLACE-PIPE LINER SECTION 02542

SECTION 810 SEWER LINE CLEANING

53.03 MATERIALS FOR SEWER LINER PIPE AND FITTINGS: The following materials are approved for installation in sanitary sewer lines:

STANDARD SPECIFICATIONS SECTION CLOSED CIRCUIT TELEVISION INSPECTION OF SEWER MAINS, MANHOLES AND LATERALS

San Antonio Water System Standard Specifications for Construction ITEM 866 SEWER MAIN TELEVISION INSPECTION

Sewer Line Rehabilitation

MODEL WEB CONTENT FOR CITY SANITARY SEWER DEPARTMENTS

SEWER BACKUPS & BASEMENT FLOODING PREVENTATIVE SOLUTIONS FOR THE BUILDING OWNER

CLEANING, INSPECTION, AND TESTING OF SEWERS

CITY OF BEVERLY RULES AND REGULATIONS - SEWER SYSTEM TESTING. General

ALL YOUR DRAINAGE NEEDS. Tel:

FY15 Gravity Sewer and Manhole Rehabilitation

SASTT contact details:

BASEMENT FLOODING. Prevention Guide for. Homeowners

Property Care White Papers. Site Drainage: Monitor and Maintain

Sewer Rehabilitation Design Requirements

VIDEO INSPECTION AND LASER PROFILING IN FLORIDA. AASHTO SOC Conference Larry Ritchie, FDOT August 14, 2013

Sewer Pipe Lining An Economic Solution for Pipe Rehabilitation By Tawana Albany Nicholas, Virgin Islands Waste Management Authority

Platte River Interceptor Slipline Rehabilitation

Work Practice: Wastewater Collection System Maintenance Plan Potential Safety Hazards

TABLE OF CONTENTS. Manhole, Frame, and Cover Installation (includes Drop Manhole) Additional Manhole Depth

812-3 LIMITATIONS: b. No fire hydrant shall be obstructed or used when there is a fire in the area.

REVIEW OF TRENCHLESS TECHNIQUES FOR THE REHABILITATION OF SEWERS. Gerhard (Gerry) P. Muenchmeyer, P.E. Muenchmeyer Associates, LLC

SECTION IV - TESTS AND INSPECTIONS PART 1 - GENERAL Testing - General

SECTION 812 SEWER LINE, MANHOLE AND WET WELL CLEANING

SECTION GRAVITY SANITARY SEWERS

Water Main Lining A Sustainable Alternative to Open Cut Replacement

PLANNING CAREFUL NORTH VANCOUVER PIPE BURST REQUIRES

Emerging Technologies in Wastewater Collection Systems

Section 402. STORM SEWERS

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

UVDB empowered by Achilles

City of Mill Valley Sewer Capital Improvement Plan

CURED-IN-PLACE PIPE MINIMIZING RISK BY DEFECT CODING

Sewer Water Pipeline Replacement with CERTA LOK RESTRAINED JOINT PVC PIPE

March 2006 DIVISION 3 - CW 2140-R3 TABLE OF CONTENTS

Sewer systems: Failures and rehabilitation

SECTION POINT REPAIRS TO SANITARY SEWERS. A. Repairs to existing sewer lines by replacing short lengths of failed pipe.

Phased Assessment Strategy for Sewers

MIAMI-DADE LATERAL PILOT PROGRAM. James T. Cowgill, P.E. Rodney J. Lovett Franklin Torrealba, P.E.

SECTION 724 PIPE CULVERTS

INFORMATION PACK. Registered Company Address. Contact Names Robert Hatton Chris Jones. Telephone

Specifications for Residential Property Owners Connection to New Public Sewer

Utilizing Remaining Useful Life for Asset Management of Critical Wastewater Assets

SANITARY SEWER BACKUP. Causes & Prevention

SA Pipe Relining is dedicated to finding simple, non intrusive

WEFTEC.06. Kent Von Aspern,* Collins Orton** *Carollo Engineers 2700 Ygnacio Valley Rd Suite 300 Walnut Creek, CA 94598

Sewer System Inspection: Techniques and Resources. Presented by: Doug Severson

Home page Previous Next

SANITARY SEWER SPECIFICATIONS

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

First in Service First in Safety

Overview of PG&E Cross Bore Inspection Program

Township of Enniskillen. Asset Management Plan

ATTACHMENT 2: SPECIFICATION FOR SEWER CCTV VIDEO INSPECTION

CCTV of Stormwater Systems. Cairns Regional Council. Commentary Guidelines #

Public Works Operations Manual Standard Operating Procedures for Water and Sewer WS-A412 Water Connection Repair

City of Bakersfield Public Works Department Sewer System Management Plan December 2014

Installation of Large Diameter Buried Pipes

Collection Systems Technology Fact Sheet Sewers, Conventional Gravity

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

CORPORATION OF THE CITY OF BURLINGTON SPECIFICATION INDEX FOR CCTV VIDEO INSPECTION OF PROPOSED STORM SEWERS (SPEC. NO. SS7) 1. Scope of Work SS7-1

SECTION 21 REHABILITATION OF SANITARY SEWER MAINS BY THE PIPE BURSTING AND TRENCHLESS PIPE REPLACEMENT METHOD

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

Greater Dublin Strategic Drainage Study Regional Drainage Policies - Volume 2 New Development

Royal Seal Gasketed Sewer Pipe

SIDE SEWER CONDITION ASSESSMENT AND REPAIR RECOMMENDATIONS

SPR PE Steel Reinforced Liner

Transcription:

U UNDERGROUND INFRASTRUCTURE SPECIALISTS TABLE OF CONTENTS 3. COMPANY PROFILE A growing company excelling in the fields of infrastructure repair and maintenance. 6. MANDREL TESTING Individually approved for use by the City of Calgary 4. COMMITMENT TO SAFETY Thuro takes great pride in providing a safe work environment for employees and clients. 7. REPAIR SYSTEMS AND TRENCHLESS TECHNOLOGY Affordable rehabilitation methods eliminating large excavations. SERVICES 5. PIPELINE & SEWER INSPECTION SERVICES CCTV Video Inspection remains the best tool for evaluating structural defects in under ground pipes. 9. POWER FLUSHING AND VACUUMING Maintenance is easy with our fleet of Power Flushers and Vacuum Trucks. 10. HYDRO VAC Safe and accurate excavation methods.

COMPANY PROFILE 1 COMMITMENT TO SAFETY 2 PIPELINE & SEWER INSPECTION SERVICES 3 POWER FLUSHING & VACUUMING 4 REPAIR SYSTEMS&TRENCHLESS TECHNOLOGY 6 PROFILE MANDREL TESTING 8 Thuro Inc. is one of the largest and most diversified Sewer Cleaning, Maintenance and Repair companies in western Canada. The Current owner and founder Alex Varro established Thuro Inc. in 1969. The company began with a single Flusher Truck to service sanitary and storm mainlines. As the need for this service grew, so did Thuro, and a diverse company excelling in the field of infrastructure repair and maintenance evolved. Thuro Inc. is well established in Alberta and also services B.C. and Saskatchewan. Thuro s office, shop and secured yard is located in the Foothills Industrial Park in Calgary Alberta. Thuro s customer base consists of commercial and residential customers including Towns and Municipalities, Property Managers, Individual Home Owners, Construction Companies, Business Owners and Engineering Firms. Thuro Inc. offers services in Trenchless Technology (CIPP Liners & Pipe Bursting), CCTV Pipe Inspection, Mandrel Testing, Power Flushing, Vacuum and Disposal Service, as well as wide range of Repair and Maintenance Services on water and sewer systems. Thuro s use of Trenchless Technology is a cost effective alternative to dig and replace methods. This technique saves excavation time and damage, traffic control and business/homeowner disruption. Thuro is one of two indemnified City of Calgary contractors for CIPP Pipe Lining and Pipe Bursting. Thuro excels in the fields of CCTV Inspection and Mandrel Testing, which are growing at a rapid rate across Canada. The inspection data generated through these methods is relied upon in making informed decisions regarding required maintenance and repair of our aging infrastructure. These methods are also employed to verify the quality of new sewer and water systems. Thuro s Inspection Technicians are NASSCO certified and recognized for their professionalism and the quality of their work. SERVING MUNICIPAL, COMMERIAL & RESIDENTIAL 4650 50TH AVENUE SE CALGARY AB 403.243.0276 www.thuro.ab.ca

C COMMITED TO SAFETY Thuro Inc. is an active member of the Alberta Construction Safety Association, and is registered in the Partnerships in Injury Reduction program with Alberta Worker s Com- pensation. Thuro maintains a certificate of Recognition with A.C.S.A. It is our company s policy to comply with all O.H. & S. regulations. Thuro provides extensive training for our operators to al- low them to work safely and efficiently. This training in- cludes, but is not limited to, WHIMIS, TDG, First Aid, Con- fined Space Entry and Rescue and Vehicle Pre-Trip Inspec- tion. Thuro Inc. is registered with W.C.B. in all four Western Provinces. All accounts are in good standing. Our Workers are covered under the relative W.C.B. plans throughout Western Canada. www.thuro.ab.ca

PIPELINE IPELINE & S & SEWER INSPECTION Thuro Inc. utilizes remote television cameras for inspecting underground sewers and pipelines. The camera is a self-contained unit which is drawn through the pipe, and using its own light source, transmits a picture of the inside conditions of the pipe to the operator in the video van. The inspection results are captured on DVD for a permanent record. Defects along with their corresponding distance measurement are noted on the recording as well as in a written log report. The camera is typically drawn from manhole to manhole by a pressure flushing machine. A remote crawler is also available for conveying the camera when access is restricted to one end. The camera can be used for inspecting pipe diameters from 3 through 48 with a maximum cable length of 2500 feet. Similarly, the video camera can be lowered into water wells and boreholes. Closed Circuit Video Inspection remains the best tool for evaluating structural defects in underground pipes. There are many reasons for conducting sewer inspections, several are listed below: Inspection of sewer lines should be performed to avoid having to repair underground lines after the roads have been resurfaced. Sewer lines adjacent to water mains scheduled for replacement should be inspected to avoid having two excavations. Inspection of new sewer lines to ensure compliance to engineering specifications. Evaluating current conditions of pipe, infiltration problems and the effectiveness of cleaning operations. Planning renewals of older sewer systems.

MANDREL TESTING Mandrel testing is used to determine that the ovality of flexible sewer pipe meets design specification. This testing is critical to the long-term performance of PVC sewer lines being installed today. It ensures that new lines have been installed and bedded properly. Mandrels are assembled to the appropriate size and drawn through the lines to verify that the line s internal dimension meets the required specification. Thuro s light-weight aluminum deflection gauges utilize a nine-fin configuration which conforms to accepted practice for mandrel design. This allows for the passage of sewage when testing live sewers. Thuro proving rings are designed as Go + No Go devices that easily verify that each deflection gauge is within tolerance. They incorporate both oversize and undersize testing dimensions and are plated with corrosion resistant zinc. Thuro proving rings manufactured for use in The City of Calgary are each stamped with a unique serial number and receive individual approval for use in writing from the City of Calgary Water Resources - Research, Policy and Standards Team. www.thuro.ab.ca

LINING Lining offers many benefits not only to the installation contractor, but to the property owner as well. CIPP Lining can eliminate recurring problem blockages and related damages from root intrusion. The liners can correct structural defects by spanning broken, cracked or missing sections of pipe and can greatly reduce groundwater infiltration/exfiltration where installed. Thuro Inc. utilizes two methods of CIPP Lining, Full Segment and Point Repair. Full segment is installed throughout the entire length of pipe in cases where there are multiple problem areas. Point Repairs are generally used in pipes that only have a small problem area that can be rehabilitated with less than 3m of lining material. Full segment liners are completed in one day and a typical Point Repair project can be done in approximately 4 1/2 to 6 hours. Allows pipe rehabilitation without the costly investment of a backhoe, dump truck and trailer. Reduced potential for accidental damage to other adjacent underground utilities during standard dig and replace methods. Can eliminate street excavation, paving, traffic control problems and possible accidental excavation damage to municipal utilities. Reduced landscape damage and restoration costs compared to conventional dig and replace methods. Minimal inconvenience to property owner during the rehabilitation as work can be performed from the building exterior. Elimination of future soil compaction and settling. Lower costs compared to dig and replace method, especially in congested areas

REPAIR & TRENCHLESS TECHNOLOGY PIPE BURSTING Rehabilitation of sewers unsuitable for CIPP Lining. Lower Risk of damage to underground utilities. Work can typically be completed in 2 days. Offers a continuous pipe with plastic welded joints Replaces the sewer service without having to excavate the entire yard or area. Uses patented British Gas Technology and High Density Plastic Pipe (HDPE) ensuring strength and durability. Can be used under trees, sidewalks, fences, retaining walls, garages and flower beds with minimal damage. Pipe Bursting is the environmental solution to replacing sewer lines. Only minimal digging is required, an insertion pit in or near the building and a winch pit at the property line. Once the minor excavation is complete, a cable is pulled through the old sewer pipe. The bursting head is then attached at the insertion pit and is winched through. As the head bursts the old pipe and pushes it into the surrounding soil, it simultaneously pulls the new HDPE pipe through, completely replacing the damaged sewer line. An expander on the head increases the diameter slightly so the friction on the new pipe is not significant. When the new pipe reaches the winch pit it is then detached and the new sewer line is hooked up. Finally it is Video Inspected to ensure a successful installation.

ACUUMING & H YDRO VAC AC POWER FLUSHING With our Flusher Truck operating from the surface, an operator inserts the flusher hose into the sewer pipe through the Manhole. Backward facing jets propel the nozzle providing all of it s forward thrust. The forward facing jet pierces blockages in it s path. & HYDRO As the nozzle is pulled back, the walls of the sewer pipe are cleaned and debris is flushed out. High Pressure and volume achieves maximum cleaning results., V, VACUUMING POWER FLUSHING LUSHING, V VACUUMING Thuro s fleet of Vacuum Trucks range from low profile units for underground parkades to large tandem trucks for lift stations, septic systems and various pits and sumps. Tank volumes range from 700 gallons to 3000 gallons.

HYDRO VAC Thuro Inc. proudly serving the Municipal, Industrial and Construction Sectors. Uncovering buried lines and cable without fear of damage to services and to the environment. Unlike traditional mechanical excavation, the Hydro-Vacuum uses high pressure water and a large volume vacuum to excavate. Hydro-Vacuum loads and excavates simutaneously, making our service fast and cost effective. Can be used to excavate in heard to reach areas, such as along buildings and fence lines. www.thuro.ab.ca

Proud Distributor of: SHAMROCK PIPE TOOLS For more information please contact: THURO INC. 4650 50TH AVENUE S.E. CALGARY, ALBERTA T2B 3R4 PHONE: 403.243.0276 E-MAIL: INFO@THURO.AB.CA www.thuro.ab.ca