CudaTel Tech Bulletin: Best Practices for Emergency Routing



Similar documents
SIP Trunking Test Results for CudaTel Communication Server

Peer-to-Peer SIP Mode with FXS and FXO Gateways

Tech Bulletin IPitomy AccessLine SIP Provider Configuration

nexvortex Setup Guide

Configuring Positron s V114 as a VoIP gateway for a 3cx system

SIP Trunking using the Optimum Business SIP Trunk Adaptor and the FortiVoice IP-PBX

THINKTEL COMMUNICATIONS CUDATEL PHONE SYSTEM 270. High Availability and SIP-TRUNK Configuration

Enabling NAT and Routing in DGW v2.0 June 6, 2012

Fonality. Optimum Business Trunking and the Fonality Trixbox Pro IP PBX Standard Edition V p13 Configuration Guide

Configuration Notes 0215

Mediatrix 3000 with Asterisk June 22, 2011

How to Config MTG1000B With T1 and Elastix

3CX Guide sip.orbtalk.co.uk

Knowledgebase Solution

Vocia MS-1 Voice-over-IP Interface. Avaya System Verification. Configuring Avaya Aura Session Manager system with Biamp s Vocia MS-1

Optimum Business SIP Trunk Set-up Guide

Copyright ZYCOO All Rights Reserved 1 / 8

Configuring the Synapse SB67070 SIP Gateway from AT&T for Clearfly SIP Trunking. January 2013

VoIPon Tel: +44 (0) Fax: +44 (0)

THINKTEL COMMUNICATIONS DIGIUM G100/G200 PRI OVER IP SIP TRUNKING

Using IPsec VPN to provide communication between offices

Alcatel-Lucent OXO Configuration Guide. For Use with AT&T s IP Flexible Reach Service. Version 1 / Issue 1 Date July 28, 2009

How to Configure the Allworx 6x, 24x and 48x for use with Integra Telecom SIP Solutions

AudioCodes Mediant 1000 Configuration Guide

SIP Internet Telephony Gateway

How to Configure the Cisco UC500 for use with Integra Telecom SIP Solutions

Wave 500 IP PBX v4.5. SIP Trunking using the Optimum Business Sip Trunk Adaptor and the Wave 500 IP PBX v4.5

Application Notes for configuring Avaya IP Office IP500 R7.0 with 2Ring NetFAX R3.0 Issue 1.0

Application Notes for Multi-Tech FaxFinder IP with Avaya IP Office Issue 1.0

How to Configure MTG200 with FreePBX

Direct IP Calls. Quick IP Call Mode

SIP Trunking using Optimum Business SIP Trunk Adaptor and the Allworx 6x IP PBX

Configuration Notes 283

Configuring an Etherspeak SIP Trunk in Microsoft Lync 2013

How to Create a Virtual Switch in VMware ESXi

Grandstream Networks, Inc. How to Integrate UCM6100 with Microsoft Lync Server

Configuring the PBX Call Routing Table for outbound calls (with security against unsecured calls)

Configuring PPP And SIP

TALKSWITCH VOIP NETWORK TROUBLESHOOTING GUIDE

Quick Installation Guide

Internet Telephony PBX System

SIP Trunking using the EdgeMarc Network Services Gateway and the Mitel 3300 ICP IP-PBX

Grandstream Networks, Inc. How To Interconnect Multiple UCM6510 IPPBX

2100 Series VoIP Phone

ZyXEL IP PBX Support Note. ZyXEL IP PBX (X2002) VoIP. Support Notes

F-SECURE MESSAGING SECURITY GATEWAY

Cisco Unified Communications Manager SIP Trunk Configuration Guide for the VIP-821, VIP-822 and VIP-824

How to Configure the NEC SV8100 for use with Integra Telecom SIP Solutions

Configuring IPsec VPN with a FortiGate and a Cisco ASA

Configuring a Pure-IP SIP Trunk in Lync 2013

Allo PRI Gateway and Elastix Server

UCM61xx Configuration

How to Configure an Initial Installation of the VMware ESXi Hypervisor

Avaya IP Office SIP Trunk Configuration Guide

Configuring PA Firewalls for a Layer 3 Deployment

SIP Trunking using Optimum Business SIP Trunk Adaptor and the Cisco Call Manager Express Version 8.5

EarthLink Business SIP Trunking. Switchvox SMB 5.5 & Adtran SIP Proxy Implementation Guide

How To Create A Virtual Private Cloud In A Lab On Ec2 (Vpn)

How to Configure the Toshiba Strata CIX for use with Integra Telecom SIP Solutions

Optional VBP-E at the Headquarters Location

XO SIP Service Customer Configuration Guide for Interactive Intelligence Customer Interaction Center (CIC) with XO SIP

Best Practices: Pass-Through w/bypass (Bridge Mode)

AT&T IP Flex Reach/ IP Toll Free Configuration Guide IC 3.0 with Interaction SIP Proxy

IP Office Technical Tip

Session Title: Exploring Packet Tracer v5.3 IP Telephony & CME. Scenario

Cisco Unified Communications Manager SIP Trunk Configuration Guide

Teletics Application Note. Using the Feature Server with SIP Trunks

IP PBX. SD Card Slot. FXO Ports. PBX WAN port. FXO Ports LED, RED means online

IP Phone Presence Setup

Abstract. Avaya Solution & Interoperability Test Lab

Grandstream Networks, Inc. Guide on Interconnecting Multiple

OfficeServ 7100 IP-PBX. SIP Trunking using the Optimum Business Sip Trunk Adaptor and the Samsung

Installation & Operations Manual. VoIP Interface 2100-VOIPLC VoIPLC

How to set fax using Dinstar s gateway and 3CX

SIP Trunking Configuration Guide for Barracuda Phone System Release 3.x. Document Version 0.5

Application Notes for MultiTech FaxFinder IP with Avaya IP Office Issue 1.0

Businesses Save Money with Toshiba s New SIP Trunking Feature

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

Avaya IP Office 8.1 Configuration Guide

Vega 100G and Vega 200G Gamma Config Guide

Digium Switchvox AA65 PBX Configuration

Application Note - IP Trunking

OAISYS SIP Trunk Integration

Shared Components PSTN gateways PSTN gateways New IP/PSTN Gateway Define New IP/PSTN Gateway Define the PSTN Gateway FQDN FQDN Next

Quick Installation Guide

How to Build a Simple Virtual Office PBX System Using TekSIP and TekIVR

Version Date Status Owner Released for HiPath OpenOffice ME V1 F. Kneissl / K.-W. Weigt

2N NetStar. 2N NetStar as a PBX Booster. Quick guide. Version 1.00

F-Secure Messaging Security Gateway. Deployment Guide

OfficeMaster SBA (Survivable Branch Appliance)

3CX PBX v12.5. SIP Trunking using the Optimum Business Sip Trunk Adaptor and the 3CX PBX v12.5

Using the GS8 Modular Gateway with Asterisk

DINSTAR DAG1000-4S4O with Elastix Setup Guide

Prestige 2302R Series

Route Based Virtual Private Network

SIP Trunking using Optimum Business Sip Trunk Adaptor and the Zultys MX250 IP PBX

Hosting more than one FortiOS instance on. VLANs. 1. Network topology

OfficeMaster Gate (Virtual) Enterprise Session Border Controller for Microsoft Lync Server. Quick Start Guide

Voice Internet Phone Gateway

Transcription:

CudaTel Tech Bulletin: Best Practices for Emergency Routing Description: This document describes recommended best practices for configuring the CudaTel Communication Server for 911 emergency call routing. Introduction: There are a number of things to consider when setting up emergency call routing on a phone system. Among them are: What kind of telephone service is provided (analog phone lines, PRI, SIP trunk)? For SIP trunks, does the provider support E911? Are there multiple locations? What kind of redundancy, if any, is needed? How does the provider handle testing of emergency calls? Once these questions are answered it is easier to put a plan into effect. We will consider a few common scenarios and suggest ways to configure emergency routing. To assign routes, log in to the CudaTel user interface and navigate to Providers > Call Routing. Click Add a routing entry to create a new route. The pre-defined 911 route in the CudaTel is called Emergency (USA). Analog Lines (CudaTel 270B) This is a very simple scenario. The CudaTel 270B can have up to four analog phone lines connected. Assign the Emergency (USA) route to every port which has a phone line connected. Analog Lines (ATA) All CudaTel models can connect to analog phone lines via supported analog telephone adapters (ATAs). Each FXO port on the ATA will have a corresponding SIP provider in the CudaTel user interface. Assign the Emergency (USA) route to each SIP provider for the ATA. PRI Circuits (CudaTel 370B, 470B, 670B) Each PRI circuit will have a corresponding Digital Port in the hardware providers page of the CudaTel user interface. Assign the Emergency (USA) route to each digital port that is connected to a PRI circuit from the telephone company. SIP Trunks (E911) SIP trunks supplied by a VoIP provider generally support Enhanced 911 (E911). The challenge for you as the end user will be to communicate with your VoIP provider and find out how to configure E911. It is critical to get E911 configured before you try testing. If you send a 911 call to a SIP trunk that has not been configured for E911 then you run the risk of incurring significant fees for calling the National Call Center 911 (NCC911). Always talk to your provider before testing 911 calls. Most providers will assist with configuring and testing 911 calls. In a simple one-office scenario you can just assign the Emergency (USA) route to your SIP provider gateway. Multi-office and remote-users are discussed below.

Remote Site Configuration The CudaTel Communication Server supports remote site configurations that allow for E911-enabled SIP accounts to provider the correct physical address to the 911 call center. In order to configure a remote site the following requirements must be met: A DID phone number with E911 must be created with the VoIP provider The DID number s E911 configuration must reflect the physical street address of the remote site The remote site will need a static IP address or IP address range. NOTE: the static IP address can be public or non-routable (i.e. RFC-1918) IP addresses, as long as they are consistent. The CudaTel s Sites feature allows it to identify a call based on the source IP address. IP connectivity must be established between the CudaTel and the remote location Once the above requirements have been met you can proceed with configuring the CudaTel. The following is a diagram of the scenario we are describing: Remote Location 10.2.2.0/24 456 Remote Ave Main Office 10.1.1.0/24 123 Main St The following are true for this configuration: SIP Trunk VoIP Provider with E911 on 2 DIDs 408-555-1212 123 Main St. 408-555-1313 456 Remote Ave The main office has the CudaTel. The business primary phone number is 408-555-1212. All phones in the main office have an IP address in the 10.1.1.x range. The remote location has IP connectivity to the main office. All phones in the remote location have an IP address in the 10.2.2.x range. The CudaTel has a connection the SIP trunk to the provider. The SIP provider has two DIDs, one for Main St. and one for Remote Ave. The objective of our configuration is the following: 911 calls from the main office should display 123 Main St. to the 911 call center 911 calls from the remote office should display 456 Remove Ave. to the 911 call center No 911 calls from the remote location should show 123 Main St. No 911 calls from the main location should show 456 Remote Ave. Normal non-emergency calls from the remote location should display the main business phone number (408-555-1212) and not the DID that is used for E911 at the remote location.

With this in mind, the steps needed to complete this configuration are: Add a provider entry for our SIP trunk Add a site entry for the remote location Add a new call type to handle E911 for the remote location Configure outbound call routing rules for the remote and main locations Navigate to Providers > SIP Providers and click New SIP Account. Use the information supplied by the provider to fill out the form. (Additional information is available in chapter 6 of the CudaTel Administrator s Guide.) Click Apply Gateway Settings to save your changes. In the screenshots below our provider is named Example_Provider. Navigate to Configuration > Sites and click Add a site. Name the site Remote Location and select Subnet/IP Address from the drop-down list. Click Create site. The site now appears in the list. Click Add a range and put in the IP address and subnet of the remote office. Our example uses 10.2.2.0 and 255.255.255.0, respectively. Click Add IP range to complete the operation. Navigate to Providers > Call Routing and click Manage Types. Click New Call Type. Use the following values: Call Type Name: Emergency (USA) Remote Location Match Condition: ^(911)$:::$1;e911_ani=4085551313 Route Type: Emergency Click Create Call Type to finish the operation. Close the Call Types view. Add the necessary routes. (Click Add a routing entry to create a new route.) Route Type Restriction Destination North America (NANPA) None Example_Provider Emergency (USA) Remote Location Site: Remote Location Example_Provider Emergency (USA) None Example_Provider

The following screen shot shows what the completed routes screen looks like: NOTE: the order in which the routes appear in the list is extremely important. The Emergency (USA) Remote Location route must appear in the list before the default Emergency (USA) route appears. If the default Emergency (USA) route appears first in the list then 911 calls from the remote location would match and go out the standard route, giving the 911 call center the physical address of the main office. At this point you are ready to test call routing. Contact your VoIP provider before you make test calls. (See below.) Testing 911 Calls It is vital that 911 calls are tested with the help of the provider. (Barracuda Networks is not liable for failed 911 calls.) Only your telephone company or VoIP provider can verify that 911 calls are working properly. Call your provider s technical support department to arrange for 911 calls to be tested. You can use the script below to make an E911 test call and verify the information that the emergency operator receives. Please note that some localities require you to schedule E911 test calls in advance and will charge penalties otherwise. You should check with your local authorities before placing any unscheduled E911 test calls. Hello, this is a non-emergency call, I'm making a Voice-Over-IP test call. Do you have a moment to verify my emergency information or can we schedule a later time to do so? Did you receive ANI information? What number do you show? (confirm that this matches the caller-id/did number that you expected to send) Were you able to retrieve ALI information? Can you verify the address that is displayed? (confirm that this matches your intended emergency address) Do you show my Call Back Number? (confirm that this matches the caller-id/did number that you expected to send) Does the information on your display appear in the proper fields? (the operator should answer yes, which confirms that none of the information fields appeared ordered incorrectly, e.g. the street number in the city field) Thank you for your time, we may be placing a couple more test calls today...

If you or your provider have questions about configuring the CudaTel for emergency call routing please contact technical support at 408-342-5300 or create a support case online at http://www.cudatel.com/support.