IBM System x and BladeCenter



Similar documents
præsentation oktober 2011

Power Redundancy. I/O Connectivity Blade Compatibility KVM Support

! '() x3250m2. x3250. x3350

Annex 1: Hardware and Software Details

Appendix 3. Specifications for e-portal

IBM System x family brochure

Cisco SmartPlay Select. Cisco Global Data Center Promotional Program

Precio Bundle. Disponibilidad. Description. Número de Parte

Cisco Unified Computing System Hardware

Tipos de Máquinas. 1. Overview x3550 M2. Features X550M2

Data Sheet FUJITSU Server PRIMERGY CX272 S1 Dual socket server node for PRIMERGY CX420 cluster server

Discount 15,000.- Discount 15,000.- Discount 15,000.- Discount 5,000.- Discount 5,000.- Discount 5,000.- Discount 5,000.- Discount 5,000.

Brocade Enterprise 20-port, 20-port, and 10-port 8Gb SAN Switch Modules IBM BladeCenter at-a-glance guide

Emulex 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter IBM BladeCenter at-a-glance guide

Redpaper. IBM BladeCenter HS22V Technical Introduction. Randall Davis David Watts

BladeCenter Interoperability Guide

QLogic 4Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter IBM BladeCenter at-a-glance guide

U.S. Product Specifications Reference PSREF. Version 483, December ThinkServer Servers. Visit for the latest version

IBM System x family brochure

IBM Flex System NAS Solutions Solution Guide

Evaluation Report: HP Blade Server and HP MSA 16GFC Storage Evaluation

High Performance 2U Storage Server. Mass Storage Capacity in a 2U Chassis

HUAWEI Tecal E6000 Blade Server

Istech Enterprise, SU905 Jalan Bandar Baru 5, Jalan Penara Jaya, Masjid Tanah, Melaka, Fax:

HP recommended configuration for Microsoft Exchange Server 2010: HP LeftHand P4000 SAN

FUJITSU Enterprise Product & Solution Facts

Pioneer DreamMicro. Blade Server S75 Series

1 of 10 12/29/ :40 AM

Fujitsu PRIMERGY Servers Portfolio

5520UR 00UR 00UR 625UR 625URSAS 00UR URBRP 600URLX 625URLX

Up to 4 PCI-E SSDs Four or Two Hot-Pluggable Nodes in 2U

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and IBM FlexSystem Enterprise Chassis

Arrow ECS sp. z o.o. Oracle Partner Academy training environment with Oracle Virtualization. Oracle Partner HUB

The MAX5 Advantage: Clients Benefit running Microsoft SQL Server Data Warehouse (Workloads) on IBM BladeCenter HX5 with IBM MAX5.

SUN HARDWARE FROM ORACLE: PRICING FOR EDUCATION

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

How To Write An Article On An Hp Appsystem For Spera Hana

SAN TECHNICAL - DETAILS/ SPECIFICATIONS

Redpaper. IBM BladeCenter HS22 Technical Introduction. Randall Davis David Watts

IBM Power Systems Facts and Features POWER7 Blades and Servers October 2010

IBM i on a POWER blade (read-me first)

NEC EXPRESS5800/R320c-E4 Configuration Guide

HP ProLiant Server Booklet. Virtualization Reliability Efficiency Agility

Part-1: SERVER AND PC

High Performance 1U Server. High Performance 1U Storage Server. Front Parallel CPU Design features better cooling

APACHE HADOOP PLATFORM HARDWARE INFRASTRUCTURE SOLUTIONS

Analyzing the Virtualization Deployment Advantages of Two- and Four-Socket Server Platforms

Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I

IBM Storwize V5000 and Windows Storage Server Product Guide

HP Cloudline Overview

Chapter 5 Cubix XP4 Blade Server

IBM PureSystems: Familia de Sistemas Expertos Integrados

Cisco UCS C24 M3 Server

Power Efficiency Comparison: Cisco UCS 5108 Blade Server Chassis and Dell PowerEdge M1000e Blade Enclosure

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

Terms of Reference Microsoft Exchange and Domain Controller/ AD implementation

HP recommended configuration for Microsoft Exchange Server 2010: ProLiant DL370 G6 supporting GB mailboxes

IBM System x3650 M3. Did you know?

Fujitsu PRIMERGY Servers Portfolio

Scout 1U Rackmount Computer

C460 M4 Flexible Compute for SAP HANA Landscapes. Judy Lee Released: April, 2015

HP high availability solutions for Microsoft SQL Server Fast Track Data Warehouse using SQL Server 2012 failover clustering

Cisco UCS B-Series M2 Blade Servers

SUN/Oracle WSCA Price List. Please call (877) SUN-LATG (877) (504) Or Fax (504) Or

CATALOGUS-CATALOGUE Online Veiling van div./ Online auction of diff./ Vente en ligne de diff. IT equipment. Sluiting-Closing-Clôture 09/03/2012

Servers, Clients. Displaying max. 60 cameras at the same time Recording max. 80 cameras Server-side VCA Desktop or rackmount form factor

Sun Microsystems Special Promotions for Education and Research January 9, 2007

Data Sheet Fujitsu PRIMERGY BX400 S1 Blade Server

Data Sheet Fujitsu PRIMERGY BX920 S2 Dual Socket Server Blade

White Paper WP01. Blade Server Technology Overview

Cisco Unified Communications on the Cisco Unified Computing System

Cisco 7816-I5 Media Convergence Server

I BM. IBM Flex System x220 Compute Node IBM Redbooks Product Guide. Did you know

TS500-E5. Configuration Guide

Hardware & Software Specification i2itracks/popiq

Cisco UCS B440 M2 High-Performance Blade Server

Virtualized High Availability and Disaster Recovery Solutions

Fujitsu PRIMERGY BX600 S3 Blade Server

ThinkServer TS140 - Overview

Data Sheet Fujitsu PRIMERGY BX900 S1 Blade Server

CUTTING-EDGE SOLUTIONS FOR TODAY AND TOMORROW. Dell PowerEdge M-Series Blade Servers

MESOS CB220. Cluster-in-a-Box. Network Storage Appliance. A Simple and Smart Way to Converged Storage with QCT MESOS CB220

IBM System x3750 M4 Intel Xeon processor-based, entry-level 4-socket server provides a balance of flexibility, price, and performance

NEC Express5800/R120f-2M System Configuration Guide

IBM Storwize V5000 and Windows Storage Server IBM Redbooks Product Guide

Data Sheet Fujitsu PRIMERGY CX122 S1 Cloud server unit for PRIMERGY CX1000

Choosing IBM Flex System for Your Private Cloud Infrastructure

Personal Systems Reference Lenovo ThinkServer Servers

REPLIES TO PRE BID REPLIES FOR REQUEST FOR PROPOSAL FOR SUPPLY, INSTALLATION AND MAINTENANCE OF SERVERS & STORAGE

DD670, DD860, and DD890 Hardware Overview

Cisco UCS C240 M4 High-Density Rack Server (Small Form Factor Disk Drive Model)

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6800 Data Center Server

Cisco UCS C220 M3 Server

UCS M-Series Modular Servers

A HIGHLY AFFORDABLE, FEATURE-RICH SERVER

Virtualisation Ready Servers from Viglen

Transcription:

IBM System x and BladeCenter x86 servers for Windows, Linux, and Virtualization Estanislao Holdowanski Consulting Sales Specialist System x and BladeCenter Mail: estanislao@jaros.com.ar Tel.: (11) 4240-4559 Celular: (11)15-5154-5409 MSN: holdowan@hotmail.com

IBM System x and BladeCenter IBM gives you fit for purpose choices for your business needs System x Enterprise High Utilization Server Consolidation, Virtualization Web 2.0, HPC, Grid, Energy Effeciency Scale Up Infrastructure Simplification, Application Serving System x idataplex High Density Scale Out Single or Multiple Applications BladeCenter Highly Integrated System x Rack and Tower High Volume

IBM System x Rack and Tower Servers Portfolio positioning Rack Systems x3750 M4 2U 4 Procesadores 768GB RAM 16 HDD 2.5 Xeon E5-4600 x3530 M4 1U 2 Procesadores 384GB RAM 4 HDD 3.5-8 HDD 2.5 Xeon E5-2400 x3550 M4 1U 2 Procesadores 768GB RAM 3 HDD 3.5-8 HDD 2.5 Xeon E5-2600 x3650 M4 2U 2 Procesadores 768GB RAM 6 HDD 3.5-16 HDD 2.5 Xeon E5-2600 x3630 M4 2U 2 Procesadores 384GB RAM 14 HDD 3.5 Xeon E5-2400 System x3250 M4 1U 1 Procesador 32GB RAM 4 HDD 2.5 Xeon E3-1200 Tower Systems All towers available as 5U Rack Mount via Configure to Order (CTO) or Option Kit Xeon E5-2600 Xeon E5-2400 Xeon E3-1200 x3500 M4 2 Procesadores 768GB RAM 8 HDD 3.5 32 HDD 2.5 x3300 M4 2 Procesadores 192GB RAM 8 HDD 3.5 16 HDD 2.5 x3100 M4 1 Procesador 32GB RAM 4 HDD 3.5 8 HDD 2.5

Intel E5-2600 Processor Transition Xeon 5600 Xeon E5-2600 Socket-R E5-2690 135W 2.80 GHz 8C Advanced Standard Basic 8MB /12 MB 6.4 GT/s QPI Hyper-Threading DDR3 1333 Turbo 8MB /12 MB 5.86 GT/s QPI Hyper-Threading DDR3 1066 Turbo Hyper-Threading 4MB cache 4.8 GT/s QPI DDR3 800 X5690 130W 3.46 GHz 6C X5675 3.06 GHz 6C X5660 2.80 GHz 6C X5650 2.66 GHz 6C E5649 2.53 GHz 6C E5645 2.40 GHz 6C E5607 2.26 GHz 4C E5606 2.13 GHz 4C 95W 95W 95W 80W 80W E5620 2.40 GHz 4C 80W 80W 80W E5603 80W 1.60 GHz 4C 39% 34% 40% 27% 43% 28% 31% 16% 23% 14% 18% 5% 46% 7% 40% 39% 44% E5-2680 130W 2.70 GHz 8C E5-2670 115W 2.60 GHz 8C E5-2660 95W 2.20 GHz 8C E5-2650 95W 2.0 GHz 8C E5-2640 95W 2.40 GHz 6C E5-2630 95W 2.20 GHz 6C E5-2620 95W 2.0 GHz 6C E5-2609 80W 2.2 GHz 4C E5-2603 80W 1.8 GHz 4C 8C-20M cache 8.0 GT/s QPI Hyper-Threading DDR3 1600 Turbo + 6C-15M cache 7.2 GT/s QPI Hyper-Threading DDR3 1333 Turbo 4C-10M 2C-5M cache 6.4 GT/s QPI DDR3 1066

IBM BladeCenter Openly designed blade server technology

IBM BladeCenter Chassis Family Five chassis choices with investment protection and compatibility IBM BladeCenter S Distributed, small office, easy to configure 7U design Up to 6 blades 110 or 208V Internal storage 2007 IBM BladeCenter E Best energy efficiency, best density 7U design Up to 14 blades Up to 8Gb midplane Best density 2002, 2006, 2009 IBM BladeCenter H High performance 9U design Up to 14 blades Up to 10Gb midplane I/O flexibility up to 8 ports 2006, 2010 Common set of blades Common set of industry-standard switches and I/O fabrics Common management infrastructure

IBM BladeCenter E Chassis Visual tour of the front of the chassis USB port Optical drive bay Handles Light Path Diagnostics Panel 7U 28 14 bays for support up to 14 blades Slot for service reference card Weight: 99 pounds Up to 240 pounds (populated)

IBM BladeCenter E Visual tour of the rear of the chassis Switch module bay 1 Power module bay 3 with PFA Switch module bay 3 Power module bay 1 with PFA Hot-swap Advanced Management Module (AMM) Switch module bay 4 Optional hot-swap redundant Advanced Management Module (AMM) Power module bay 2 with PFA Switch module Bay 2 Power module bay 4 with PFA Hot-swap redundant blowers with PFA LED panel

IBM BladeCenter H Chassis Visual tour of the front of the chassis Two bays behind bezel for hot-swap redundant power supplies with PFA and three replaceable fans on each 29 Front of Light Path Diagnostics Panel 9U Hot-swap media tray with optical bay, two USB ports, and Light Path Diagnostics panel 14 bays for support up to 14 blades Handles Slot for service reference card Weight: 90 pounds Up to 350 pounds (populated) Two bays behind bezel for hot-swap redundant power supplies with PFA and three replaceable fans on each

IBM BladeCenter H Visual tour of the rear of the chassis Redundant power input High-speed switch module bays Redundant power input Switch module bay 1 (dedicated ethernet) Dedicated bridge module slot Hot-swap Advanced Management Module (AMM) Switch module bay 3 (or bridge slot) Switch module bay 2 (dedicated ethernet) Dedicated bridge module slot Light Path Diagnostics panel Optional hotswap redundant Advanced Management Module (AMM) Switch module bay 4 (or bridge slot) Aggregated serial connector Hot-swap redundant blowers with PFA High-speed switch module bays

IBM BladeCenter S Chassis Visual tour of the front of the chassis Hot-swap media tray with optical, two USB ports, Light Path Diagnostics panel, and two battery backup bays Front of Light Path Diagnostics Panel 7U 29 Slot for service reference card Two storage module bays 6 blade server bays Weight: 90 pounds Up to 240 pounds (populated)

IBM BladeCenter S Visual tour of the rear of the chassis Module Bay 1 Module Bay 3 for Ethernet Module for Ethernet, FC, or SAS (for DSM) (via integrated ethernet on blade) (via CFFv adapter on blade) Hot-swap Advanced Management Module (AMM) Two standard hotswap redundant watt power supplies (950W at 110V, or 1450W at 220V) with PFA Provides ample enough power for two blades, one Disk Storage Module with six drives, and Module Bays 1 and 3 7U LED panel Module Bay for optional Serial Pass- Through Module Two optional hot-swap redundant watt power supplies (950W at 110V, or 1450W at 220V) with PFA Four hot-swap redundant cooling fans with PFA Module Bay 2 Module Bay 4 for future ethernet use for Ethernet, FC, or SAS (for DSM) (via CFFh adapter on blade) (via CFFv adapter on blade)

IBM BladeCenter Advanced Management Module (AMM) Visual tour of the management module Hot-swap Advanced Management Module Remote keyboard, video, mouse (KVM) Remote drive USB virtualization Status LEDs Serial port (RJ45) Concurrent keyboard, video, mouse* Video DB-15 Optional hot-swap redundant Advanced Management Module Concurrent remote drive* Concurrent media tray* * Requires a concurrent capable blade server and/or adapter Ethernet RJ45 USB dual stack for mouse and keyboard

IBM BladeCenter Server Family Processing capability and flexibility HS12 Single Socket Xeon 3000 Series HS22 Two Socket Xeon 5600 Series HS23 Two Sockets Xeon E5-2600 HS22V Two Socket Xeon 5600 Series HX5 Two Socket Xeon 7500 & 6500 Series HX5 + MAX5 Two Socket Xeon 7500 & 6500 Series HX5 Four Socket Xeon 7500 Series PS700 Single Socket Power 7 PS701 Single Socket Power 7 PS703 Two Socket Power 7 PS702 Two Socket Power 7 PS704 Four Socket Power 7 QS22 Two Socket PowerXCell

IBM BladeCenter HS23 Visual tour of the blade system Internal USB connector (Embedded Hypervisor) Integrated 10GbE Virtual Fabric LOM Dual and redundant power & I/O connectors 2 x Intel Xeon E5 2600 series processors (Romley/Sandybridge EP) 2x IO Expansion Slots 1x CIOv +1x CFFh) 2x hot-swap drive bays (SAS, SATA or Solid State) 16x VLP DDR3 Memory (256GB Max / 1600MHz Max)

IBM BladeCenter HX5 Visual tour of the blade system 4x SSD drives (1.8 ) (2 per node) 4x IO Expansion Slots (2x CIOv + 2x CFFh) 32x VLP DDR3 Memory (16 per node) 4x Intel Xeon 7500 Series CPUs (2 per node) 16x memory buffers (8 per node) 2x 30mm nodes Scale Additional Features Connector Internal USB for embedded hypervisor Dual & redundant I/O and Power IMM & UEFI HX5 Configurations 2S, 16D, 8 I/O ports, 30mm 4S, 32D, 16 I/O ports, 60mm

IO ports for BladeCenter H High Speed Networking On-board to Switch bay 1 & 2 CFFh High speed switch CIOv 2 1Gb Ethernet Or 2 8Gb Fibre 4 10Gb or 2 10Gb CNA Up to 8 physical networks per blade Vertical switch slots

IO ports for BladeCenter H Traditional Networking On-board to Switch bay 1 & 2 CFFh High speed bay CIOv Vertical switch slots 2 1Gb Ethernet Or 2 8Gb Fibre 4 1Gb or Combo 2/2 With MSIM Up to 8 physical networks per blade

Why Blades? Considerations when comparing blades and rack mount servers Acquisition Costs Server Hardware Chassis Ethernet Switches Cabling Fibre Adapter Switches SFP/GBIC Cabling Systems Management Adapters Cabling Switch Ports KVM Switches Cabling Power PDU Cabling Racks Warranty Upgrades Operational Costs Space Per U or square foot Operational Power Cooling Weight Floor Weight TCO / Management Deployment Expansion Complexity Diskless Utilization

IBM BladeCenter H Chassis Visual tour of the inside of the chassis Ventilation space Blade server Upper midplane Redundant switch modules Lower midplane Redundant power and I/O connectors on front and rear of each midplane Blade server

IBM BladeCenter H Chassis Visual tour of the inside of the chassis No Single Point of Failure Redundant & hot-swap power supplies, blowers, switches, AMM 4x completely separate and redundant power bus and wiring for power supplies Redundant connectors from the blade to the mid-plane for power and I/O

Un chassis para cada necesidad Protección de la Inversión Vs. el enfoque de la competencia: Tecnología Informática Descartable BladeCenter E 2002 BladeCenter T BladeCenter H 2006 BladeCenter HT BladeCenter S 2007 2001-2002 2002-2004 HP BLe 2004-2006 HP p-class 2006 - HP c-class HP BH7800 HP BH7800 HP p-class Duró tal vez 1 año Casi 1.5 años Nuevo HP p-class Nuevo HP c-class HP BH5700 (Telco) X

IBM System Storage Making the most of more information

IBM System Storage IBM DS3500 Express

IBM DS3500 Express DS3524 Mejor Opción para Discos de Alta Performance Discos SSD, SAS 10K (24) Discos 2.5 Discos SSD, SAS 15K, SAS 10K, NL-SAS, SED DS3512 Mejor Opción para Discos de Alta Performance y Discos de Mayor Capacidad Discos NL SAS y SAS 15k (12) Discos 3.5 drives 15K, NL, SED

IBM DS3500 Express Opciones de Cajon Principal DS3524 DS3512 Opciones de Expansiones EXP3524 EXP3512

IBM DS3500 Express Se puede crecer en capacidad usando el mismo modelo de cajon de discos O se puede mezclar combiando ambos modelos de cajones de disco* * Hasta un maximo de (16) cajones o (192) Discos

IBM DS3500 Express IBM DS3500 Express 1 o 2 Controladoras SAS 6GB (Activo/Activo con dos controladoras) 3 opciones de interfaces SAS, FC+SAS, iscsi+sas Cuatro u ocho puertos 6 Gbps SAS Ocho puertos 8 Gbps FC y cuatro puertos 6 Gbps SAS Ocho puertos 1 Gbps iscsi y cuatro puertos 6 Gbps SAS Cuatro puertos 10Gbps iscsi y cuatro puertos 6Gbps SAS Hasta 192 discos Discos High performance SAS, Nearline SAS, SED SAS y SSD EXP3512 (2U 12 x Discos 3.5 ) y EXP3524 (2U 24 x Discos 2.5 ) 1 o 2GB de CACHE por Controladora Software: Thin Provisioning, FlashCopy, VolumeCopy, Remote Mirror Opcional de TURBO Performance Monitor de Performance

IBM DS3500 Express: Flexibilidad Conectividad a servidores concurrentes con iscsi/sas o FC/SAS Un solo sistema de almacenamiento para cumplir con los diferentes requerimientos de las aplicaciones Servidores secundarios dispersos en SAN iscsi de 1 Gbps Servidores productivos locales o Blade Center en conexiones SAS de 6Gbps Servidores productivos dispersos en SAN FC de 8 Gbps Servidores prductivos locales o Blade Center en conexiones SAS de 6Gbps

IBM DS3500 Express: Flexibilidad ALMACENAMIENTO PRIMARIO SAS SAS NL ALMACENAMIENTO SECUNDARIO SAS SSD SAS SED SEGURIDAD Discos de 2.5 para aplicaciones que demandan IOPS Discos de 3.5 para demanda de CAPACIDAD

IBM DS3500 Express: Opciones de Discos DS3524 / EXP3524 (24) Discos 2.5 en 2U DS3512 / EXP3512 (12) Discos 3.5 en 2U SSD 200/400 GB --- 15K SAS 146 GB 300/450/600 GB 600 GB SED 10K SAS 300/600/900 GB 300 GB SED --- NL-SAS 500/1000 GB 1000/2000/3000 GB

IBM BladeCenter Why blades?

Why Blades? Considerations when comparing blades and rack mount servers Controladora A Controladora B P/N Qty Descripción Precio de Venta Pr. Unitario Pr. Total Servidores 7914EBU 4 Express x3550 M4, Xeon 6C E5-2620 95W 2.0GHz/1333MHz/15MB, 1X8GB, O/Bay 2.5in HS $ 3,162.65 $ 12,650.58 SAS/SATA, SR M5110, Multi-Burner, 550W p/s, Rack 69Y5675 4 Intel Xeon 6C Processor Model E5-2620 95W 2.0GHz/1333MHz/15MB W/Fan $ 1,060.70 $ 4,242.78 49Y1397 12 8GB (1x8GB, 2Rx4, 1.35V) PC3L-10600 CL9 ECC DDR3 1333MHz LP RDIMM $ 306.18 $ 3,674.16 46M0907 8 IBM 6Gb SAS HBA $ 298.89 $ 2,391.12 46C7526 4 IBM Virtual Media Key $ 168.89 $ 675.54 94Y6668 4 IBM System x 550W High Efficiency Platinum AC Power Supply $ 206.55 $ 826.20 Storage 1746A4D 1 IBM System Storage DS3524 Express Dual Controller Storage System $ 6,181.67 $ 6,181.67 49Y2048 5 600GB 2.5in 10K 6Gb SAS HDD $ 737.81 $ 3,689.05 68Y8431 2 6Gb SAS 2 Port Daughter Card $ 791.99 $ 1,583.98 39R6531 8 IBM 3m SAS Cable $ 118.12 $ 944.96 Precio TOTAL sin IVA: $ 36,860.04

Why Blades? Considerations when comparing blades and rack mount servers Controladora A Controladora B P/N Qty Descripción Precio de Venta Pr. Unitario Pr. Total 86774TU 1 Chasis IBM eserver BladeCenter(tm) Chassis with 2x2320W PSU $ 5,557.22 $ 5,557.22 39Y9324 2 Server Connectivity Module for IBM BladeCenter $ 1,424.69 $ 2,849.39 39Y9195 2 IBM BladeCenter SAS Connectivity Module $ 710.87 $ 1,421.74 Servidores 7875E1U 4 Express HS23, 2xXeon 6C E5-2620 95W 2.0GHz/1333MHz/15MB, 8x4GB, O/Bay 2.5in SAS $ 4,500.00 $ 18,000.00 43W4068 4 SAS Connectivity Card (CIOv) for IBM BladeCenter $ 125.15 $ 500.58 Storage 1746A4D 1 IBM System Storage DS3524 Express Dual Controller Storage System $ 6,181.67 $ 6,181.67 49Y2048 5 600GB 2.5in 10K 6Gb SAS HDD $ 737.81 $ 3,689.05 39R6531 2 IBM 3m SAS Cable $ 118.12 $ 236.24 Precio TOTAL sin IVA: $ 38,435.89 Page 36

Why Blades? Considerations when comparing blades and rack mount servers Page 37

Why Blades? Considerations when comparing blades and rack mount servers P/N Qty Descripción Pr. Unitario Precio de Venta Pr. Total 7914EBU 5 69Y5675 5 49Y1397 15 Servidores Express x3550 M4, Xeon 6C E5-2620 95W 2.0GHz/1333MHz/15MB, 1X8GB, O/Bay 2.5in HS SAS/SATA, SR M5110, Multi-Burner, 550W p/s, Rack Intel Xeon 6C Processor Model E5-2620 95W 2.0GHz/1333MHz/15MB W/Fan 8GB (1x8GB, 2Rx4, 1.35V) PC3L-10600 CL9 ECC DDR3 1333MHz LP RDIMM $ 3,162.65 $ 15,813.23 $ 1,060.70 $ 5,303.48 $ 306.18 $ 4,592.70 42D0501 10 QLogic 8Gb FC Single-port HBA for IBM System x $ 955.32 $ 9,553.24 46C7526 5 IBM Virtual Media Key $ 168.89 $ 844.43 94Y6668 5 IBM System x 550W High Efficiency Platinum AC Power Supply $ 206.55 $ 1,032.75 Storage 249824E 2 Express IBM System Storage SAN24B-4 $ 6,620.94 $ 13,241.89 39M5697 4 5m Fiber Optic Cable LC-LC $ 45.37 $ 181.48 45W0501 4 SFP 8 Gbps SW 8-Pack $ 510.60 $ 2,042.41 1746A4D 1 Storage IBM System Storage DS3524 Express Dual Controller Storage System $ 6,181.67 $ 6,181.67 49Y2048 5 600GB 2.5in 10K 6Gb SAS HDD $ 737.81 $ 3,689.05 68Y8432 2 8Gb FC 4 Port Daughter Card $ 1,457.71 $ 2,915.43 39M5697 8 5m Fiber Optic Cable LC-LC $ 45.37 $ 362.96 Precio TOTAL sin IVA: $ 65,754.69 Page 38

Why Blades? Considerations when comparing blades and rack mount servers Controladora A Controladora B P/N Qty Descripción Precio de Venta Pr. Unitario Pr. Total Chasis 86774TU 1 IBM eserver BladeCenter(tm) Chassis with 2x2320W PSU $ 5,557.22 $ 5,557.22 39Y9324 2 Server Connectivity Module for IBM BladeCenter $ 1,424.69 $ 2,849.39 44X1921 2 Brocade 10-port 8 Gb SAN Switch Module for IBM BladeCenter $ 7,971.64 $ 15,943.28 44X1962 4 Brocade 8 Gb SFP+ SW Optical Transceiver $ 298.39 $ 1,193.55 Servidores 7875E1U 5 Express HS23, 2xXeon 6C E5-2620 95W 2.0GHz/1333MHz/15MB, 8x4GB, O/Bay 2.5in SAS $ 4,500.00 $ 22,500.00 44X1945 5 QLogic 8Gb Fibre Channel Expansion Card (CIOv) for IBM BladeCenter $ 1,225.81 $ 6,129.05 Storage 1746A4D 1 IBM System Storage DS3524 Express Dual Controller Storage System $ 6,181.67 $ 6,181.67 49Y2048 5 600GB 2.5in 10K 6Gb SAS HDD $ 737.81 $ 3,689.05 68Y8432 2 8Gb FC 4 Port Daughter Card $ 1,457.71 $ 2,915.43 39M5697 4 5m Fiber Optic Cable LC-LC $ 45.37 $ 181.48 Precio TOTAL sin IVA: $ 67,140.11 Page 39

Why Blades? Considerations when comparing blades and rack mount servers Controladora A Controladora B P/N Qty Descripción Precio de Venta Pr. Unitario Pr. Total Chasis 86774TU 1 IBM eserver BladeCenter(tm) Chassis with 2x2320W PSU $ 5,557.22 $ 5,557.22 39Y9324 2 Server Connectivity Module for IBM BladeCenter $ 1,424.69 $ 2,849.39 39Y9195 2 IBM BladeCenter SAS Connectivity Module $ 710.87 $ 1,421.74 Servidores 7875E1U 5 Express HS23, 2xXeon 6C E5-2620 95W 2.0GHz/1333MHz/15MB, 8x4GB, O/Bay 2.5in SAS $ 4,500.00 $ 22,500.00 43W4068 5 SAS Connectivity Card (CIOv) for IBM BladeCenter $ 125.15 $ 625.73 Storage 1746A4D 1 IBM System Storage DS3524 Express Dual Controller Storage System $ 6,181.67 $ 6,181.67 49Y2048 5 600GB 2.5in 10K 6Gb SAS HDD $ 737.81 $ 3,689.05 68Y8431 2 6Gb SAS 2 Port Daughter Card $ 791.99 $ 1,583.98 39R6531 8 IBM 3m SAS Cable $ 118.12 $ 944.96 Precio TOTAL sin IVA: $ 45,353.73 Page 40

Why Blades? Considerations when comparing blades and rack mount servers 4 x3650 + DS 3500 SAS u$s 36.860 BladeCenter E + 4 HS23 + DS3500 SAS u$s 38.435 5 x3650 + DS 3500 FC u$s 65.754 BladeCenter E + 5 HS23 + DS3500 FC u$s 67.140 BladeCenter E + 5 HS23 + DS3500 SAS u$s 45.353

IBM PureSystems are integrated by design Middleware Development Deployment Applications PureApplication System Optimizes the complete solution stack: Management PureFlex System Virtualization Flex System All hardware and software components integrated and optimized Born virtualized and ready for cloud Storage tuned to data needs Hardware directly tuned to the software System resource allocation uniquely optimized per selected pattern for each application workload Storage Networking Servers

GRACIAS! Preguntas?