IncidentMonitor Server Specification Datasheet



Similar documents
Sage Grant Management System Requirements

How To Create A Multi Disk Raid

Enterprise Edition. Hardware Requirements

RAID HARDWARE. On board SATA RAID controller. RAID drive caddy (hot swappable) SATA RAID controller card. Anne Watson 1

Assessing RAID ADG vs. RAID 5 vs. RAID 1+0

Professional and Enterprise Edition. Hardware Requirements

RAID Made Easy By Jon L. Jacobi, PCWorld

STI Hardware Specifications for PCs

NEXTGEN v5.8 HARDWARE VERIFICATION GUIDE CLIENT HOSTED OR THIRD PARTY SERVERS

How to choose the right RAID for your Dedicated Server

RAID Basics Training Guide

Gladstone Health & Leisure Technical Services

MedInformatix System Requirements

PIONEER RESEARCH & DEVELOPMENT GROUP

technology brief RAID Levels March 1997 Introduction Characteristics of RAID Levels

VERY IMPORTANT NOTE! - RAID

HARDWARE AND SOFTWARE REQUIREMENTS

Patriot Hardware and Systems Software Requirements

Ignify ecommerce. Item Requirements Notes

Lecture 36: Chapter 6

Adonis Technical Requirements

SYSTEM SETUP FOR SPE PLATFORMS

Very Large Enterprise Network, Deployment, Users

Storage node capacity in RAID0 is equal to the sum total capacity of all disks in the storage node.

RAID 5 rebuild performance in ProLiant

Enterprise Planning Large Scale ARGUS Enterprise /29/2015 ARGUS Software An Altus Group Company

Sage CRM Technical Specification

Molecular Devices High Content Data Management Solution Database Schema

Distribution One Server Requirements

What is RAID? data reliability with performance

Grant Management. System Requirements

IBM ^ xseries ServeRAID Technology

Microsoft Dynamics CRM 2011 Guide to features and requirements

Very Large Enterprise Network Deployment, 25,000+ Users

Delphi+ System Requirements

Minimum Hardware Specifications Upgrades

Outline. Database Management and Tuning. Overview. Hardware Tuning. Johann Gamper. Unit 12

Hardware/Software Requirements For Self-Hosting Multi Server

Performance Report Modular RAID for PRIMERGY

Abila Grant Management. System Requirements

XenDesktop 7 Database Sizing

Visual UpTime Select Server Specifications

Delphi 2015 SP1-AP1 System Requirements

VERITAS Volume Manager Delivering High Availability Storage Management Tools for Microsoft Windows

Hard Disk Drives and RAID

System Requirements for Microsoft Dynamics SL 2015

Practical issues in DIY RAID Recovery

MANAGING DISK STORAGE

How To Test For Performance And Scalability On A Server With A Multi-Core Computer (For A Large Server)

RAID Storage System of Standalone NVR

Guide to SATA Hard Disks Installation and RAID Configuration

System Requirements for Microsoft Dynamics GP 9.0

Availability and Disaster Recovery: Basic Principles

SAN TECHNICAL - DETAILS/ SPECIFICATIONS

AlphaTrust PRONTO - Hardware Requirements

DELL RAID PRIMER DELL PERC RAID CONTROLLERS. Joe H. Trickey III. Dell Storage RAID Product Marketing. John Seward. Dell Storage RAID Engineering

Operating Systems. RAID Redundant Array of Independent Disks. Submitted by Ankur Niyogi 2003EE20367

Redundant Array of Independent Disks (RAID)

RAID. Contents. Definition and Use of the Different RAID Levels. The different RAID levels: Definition Cost / Efficiency Reliability Performance

What is RAID--BASICS? Mylex RAID Primer. A simple guide to understanding RAID

Software and Hardware Requirements

Dependable Systems. 9. Redundant arrays of. Prof. Dr. Miroslaw Malek. Wintersemester 2004/05

Terminal Server Software and Hardware Requirements. Terminal Server. Software and Hardware Requirements. Datacolor Match Pigment Datacolor Tools

Input / Ouput devices. I/O Chapter 8. Goals & Constraints. Measures of Performance. Anatomy of a Disk Drive. Introduction - 8.1

Comprehending the Tradeoffs between Deploying Oracle Database on RAID 5 and RAID 10 Storage Configurations. Database Solutions Engineering

RAID 6 with HP Advanced Data Guarding technology:

RAID Performance Analysis

Protect SQL Server 2012 AlwaysOn Availability Group with Hitachi Application Protector

Guide to SATA Hard Disks Installation and RAID Configuration

Design and Implementation of a Storage Repository Using Commonality Factoring. IEEE/NASA MSST2003 April 7-10, 2003 Eric W. Olsen

EMC Backup and Recovery for Microsoft SQL Server 2008 Enabled by EMC Celerra Unified Storage

What is RAID and how does it work?

The Application and Data Server (ADS) and Extended Application and

System requirements for A+

USER S GUIDE. MegaRAID SAS Software. June 2007 Version , Rev. B

SECURE Web Gateway Sizing Guide

New Advanced RAID Level for Today's Larger Storage Capacities: Advanced Data Guarding

Administering a Microsoft SQL Server 2000 Database

System Requirements for Microsoft Dynamics GP 2015

Microsoft Dynamics SL 7.0 System Requirements Guide

Module 6. RAID and Expansion Devices

Hardware and Software Requirements for Installing California.pro

Certification Document macle GmbH Grafenthal-S1212M 24/02/2015. macle GmbH Grafenthal-S1212M Storage system

User Guide - English. Embedded MegaRAID Software

Education. Servicing the IBM ServeRAID-8k Serial- Attached SCSI Controller. Study guide. XW5078 Release 1.00

VMware Virtual SAN Backup Using VMware vsphere Data Protection Advanced SEPTEMBER 2014

HP Smart Array 5i Plus Controller and Battery Backed Write Cache (BBWC) Enabler

RAID Level Descriptions. RAID 0 (Striping)

Performance Characteristics of VMFS and RDM VMware ESX Server 3.0.1

Synergis Software 18 South 5 TH Street, Suite 100 Quakertown, PA , version

N /150/151/160 RAID Controller. N MegaRAID CacheCade. Feature Overview

Deploying a File Server Lesson 2

System Requirements for Microsoft Dynamics GP 10.0

Tekla Structures 18 Hardware Recommendation

Intel RAID Software User s Guide:

TheraDoc v4.6.1 Hardware and Software Requirements

Transcription:

IncidentMonitor Server Specification Datasheet Prepared by Monitor 24-7 Inc October 1, 2015 Contact details: sales@monitor24-7.com North America: +1 416 410.2716 / +1 866 364.2757 Europe: +31 088 008.4600

IncidentMonitor Requirements In order to run the IncidentMonitor system, you will require the following hardware and software pieces outlined in this document. The hardware platform to run IncidentMonitor is recommended to be something on the Microsoft Windows Server 2008 R2 or Microsoft Windows Server 2012 R2 Hardware Compatibility List (HCL). The specific server configuration options are outlined below in the following sections. The number of users that your environment needs to support will drive the exact configuration recommendation. Keep in mind that these are minimum specifications that will provide a system that is reasonable from a performance perspective. Although 18Gb disk drives are specified below, this is used to represent a minimum disk configuration. You can substitute 18Gb for whatever minimum disk drives are available. For example, at the time of this writing you can t buy 18Gb disk drives anymore, 128Gb disk drives are the minimum that can be purchased. Single Server Installation Hardware This configuration is well suited to environments where there are up to 50 resources of moderate use supporting a user community of 1,500 light to moderate users. Refer to the Determining Server(s) and Disk Configuration section below for specific information. Single Server - Fault Resilient A minimum server configuration that can sustain server component failures (fault resilient) should be equipped as follows: Intel or compatible (XEON 3Ghz or higher) dual processor server 6 Gb memory (data set size and number of users may require more memory, ask for details) RAID disk controller with 32Mb of cache or better with write back cache enabled o RAID 5 3 x 18Gb disk drives, or o RAID 1 2 x 18Gb disk drives, or o RAID 1/0 4 x 18Gb disk drives 2 x 100Mbps network card or better Multiple Server Installation Hardware This configuration is well suited to environments where a single server setup may not be sufficient for the number of resources or user community that may use the system. Sizing of these systems is really based on your environment. Refer to the Determining Server(s) and Disk Configuration section below for specific information. Database Server This is one of the critical items in the configuration and therefore should be designed to provide sufficient performance and tolerance to component failures within the server. A minimum server configuration should be equipped as follows: Intel or compatible (XEON 3Ghz or higher) dual processor server 16 Gb memory (data set size and number of users may require more memory, ask for details) RAID disk controller with 64Mb of cache or better with write back cache enabled o RAID 1 2 x 18Gb disk drives for the transaction log o RAID 1/0 4 or more 18Gb for the data storage 100Mbps network card

Web Server / Transaction Server A minimum server configuration should be equipped as follows: Intel or compatible (XEON 3Ghz or higher) dual processor server 8 Gb memory RAID disk controller with 32Mb of cache or better with write back cache enabled 100Mbps network card High Availability Multiple Server Installation Hardware This configuration is well suited to environments where 7x24 operations are a must even in times of server failures. In addition, this configuration allows you to add servers into the environment to handle a large number of users. Sizing of these systems is really based on your environment. Optionally, you can configure the database server as a cluster to provide maximum availability. Database Server This is one of the critical items in the configuration and therefore should be designed to provide sufficient performance and tolerance to component failures within the server. A minimum configuration would include two servers equipped as follows in a cluster configuration: Intel or compatible (XEON 3Ghz or higher) dual processor server 32 Gb (data set size and number of users may require more memory, ask for details) Shared RAID disk system with RAID controllers using 64Mb of cache or better with write back cache enabled (if shared disk sub system supports it) o RAID 1 2 x 18Gb disk drives for the transaction log o RAID 1/0 4 or more 18Gb for the data storage 2 x 100Mbps network card Web Server / Transaction Server For high availability environments, using multiple web servers and transaction servers coupled with Windows Load Balancing Services (WLBS) will produce an environment that can sustain complete individual server failures and still keep on functioning on the remaining servers. A minimum server configuration should be equipped as follows: Intel or compatible (XEON 3Ghz or higher) dual processor server 8 Gb memory RAID disk controller with 32Mb of cache or better with write back cache enabled 100Mbps network card

Software Requirements Server Software Requirements Windows Server 2012, Windows Server 2012 R2, Windows Server 2008, Windows 2008 R2 For high availability environments, Windows Load Balancing Services (WLBS) and Microsoft Cluster Services (MSCS) for Windows 2008/2012 operating systems that offer these features SQL Server 2014, SQL Server 2012, SQL Server 2008, SQL Server 2005 SP2 or above with cumulative hot fixes IIS 6.0 or above with SMTP Service Appropriate licenses for products and configuration (ask for details) Microsoft x86.net Framework 2.0 Microsoft Data Access Components (MDAC) version 2.71 or above Client Hardware Minimum Requirements Intel or compatible (Pentium IV 1Ghz or higher) processor Required memory in accordance with the operating system specifications + 100 Mb 100 Mb free disk space 1280 x 1024 screen resolution recommended, 1024 x 768 screen resolution requires scrolling on some screens Client Software Requirements Windows 8.X, Windows 7, Windows 2008 and R2, Windows 2012 and R2 Internet Explorer 10.x or above Chrome version 32.x and above

Disk Considerations RAID Technology The most important disk consideration in an IncidentMonitor implementation is the database server. If your environment is going to be all on one server, then it is the Web/database server disk system that should be designed properly. When it comes to sizing the disk system in your server, you should consider the following points: Disk space required for data storage. Number of drives required to sustain the required data throughput (read and write operations) for your system taking into consideration the type of Redundant Array of Inexpensive Disks (RAID) that you will use. The number and type of disk failures that you want to protect against when it comes to avoiding data loss and system outages. Amount of memory on the RAID controller card for data caching operations. Most RAID controllers today have a minimum of 64Mb on board memory for disk caching. Make sure the RAID controller supports write back cache (faster writes). You should use a controller that has a battery backup module on the controller to protect data that is in the controller s memory. The following chart outlines the common types of RAID that are used in the industry today and the strengths and weaknesses of each. RAID Level Minimum Number of Drives Description Strengths Weakness RAID 0 2 Data striping without redundancy Highest performance RAID 1 2 Disk mirroring Very high performance; Very high data protection; Very minimal penalty on write performance RAID 5 3 Block-level data striping with distributed parity RAID 1/0 4 Combination of RAID 0 (data striping) and RAID 1 (mirroring) Best cost/performance for transaction-oriented networks; Good performance, reasonable data protection; Supports multiple simultaneous reads and writes; Highest performance, highest data protection (can tolerate multiple drive failures in different matched drives) No data protection; One drive fails, all data is lost High redundancy cost overhead; Because all data is duplicated, twice the storage capacity is required Write performance is slower than RAID 0 or RAID 1; the more drives in the array the higher the probability of multiple disk failures in the array causing total drive failure High redundancy cost overhead; Because all data is duplicated, twice the storage capacity is required

Determining Server(s) and Disk Configuration The following chart outlines the number of resource licenses in IncidentMonitor and the recommended server(s) and drive system configuration for your database server or if all on one server, the Web/database server. To find your configuration, look down the left column and locate the number of resources for your environment. Then look across the row to the column that matches your desired cost/performance and data protection requirement. The number in the column represents the number of drives to be used and the RAID configuration for your system. The Web Servers, MTS Servers and DB Servers columns represent the number of the specific type of server for your implementation. In certain cases all services can be performed by a single server. If you see Combined in the list it means the server functions from the columns can be combined onto a single server. Resources Maximum Performance Maximum Data Protection RAID 1/0 High Performance High Data Protection RAID 1 Best Cost/Performance Good Data Protection RAID 5 Web Servers MTS Servers 10 4 2 3 1 combined 20 4 2 3 1 combined 50 4 4 3 1 combined DB Servers 100 6 4 4 1 combined 1 250 6 Use RAID 1/0 Use RAID 1/0 1 combined 1 500 8 Use RAID 1/0 Use RAID 1/0 1 1 1