NARROW DIAMETER implant



Similar documents
Gl GinGival level implant

GINGIVAL LEVEL implant

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

Standard Internal Hex

Regular C/X Prosthetics. Prosthetics

procedures & products NOBELESTHETICS including Procera

Restorative Guidelines

One Abutment - One Time

PROSTHETICS. Crown and bridge restorations with the synocta prosthetic system.

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

TRI-CAM Implant System

Crown and Bridge Restorations. Straumann synocta Prosthetic System

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

ITI Small Diameter (SD) external hex 3.25 / 3.3 external hex. ITI Standard 4.8 internal non-octagon Morse taper 4.

prosthetic technique manual

MS SA Implant - Narrow Ridge MS SA Implant - Denture. MS Implant - Provisional MS KIT

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

Straumann Dental Implant System. Fax Order Form Collection.*

Guidance for implant removal. Straumann Dental Implant System

BASIC INFORMATION ON THE prosthetic procedures. Straumann Bone Level Implant Line

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

PROSTHETICS. Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

STEP-BY-STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

GIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN.

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

STEP BY STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

About DENTSPLY Implants

All-on-4 treatment concept with NobelSpeedy Groovy

BEGO IMPLANT SYSTEMS PRODUCT CATALOGUE 2015 / Partners in Progress

AT THE RIGHT PRICE. ONE SIZE FITS ALL. FRICTION For a secure connection. BONEADAPT For immediate stability.

Implant Parts. A Radford Heath Guide 1

ball abutment overdenture: chairside pick-up using existing denture

Prosthetic Manual. Implant System. Contact Us: Smarter thinking. Simpler design. Phone: Fax:

Procedures & Products. NobelEsthetics

NobelActive. procedures and products

INTRODUCTION TO OSTEO-TI IMPLANTS; A NURSES MANUAL

Catalogue dental implant system ROOTT

Implant Systems MAX LOGIC MONO. Today s name in tomorrow s implant technology

How To Use A Cresco

ORTHODONTIC MINI IMPLANTS Clinical procedure for positioning. Orthodontics and Implantology

Renaissance of One-Piece Implants

Encode Restorative System Procedure & Laboratory Manual

Product Catalog. ERA Mini TM Dental Implant System

Modern Tooth Replacement Strategies & Digital Workflow

Implants in your Laboratory: Abutment Design

. Simplification. High Performance. Safety and Longevity. The fundamental goal is to restore the quality of life of patients.

platform shifting Nobel Biocare is shifting gingival beauty to the next level

Multi-unit abutment bar overdenture

The IMZ Implant System

uncompromised strength, proven success external implant system

Product Catalog Comp lete Imp lant Solu tions

Dental Implant Options in Atrophic Jaws

Khaldoon G. Abu Afifeh, B.D.S, M. Sc in Prosthodontics

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

LOCATOR Implant Attachment System for XiVE, FRIALIT and ANKYLOS Implants

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments

SCD Case Study. Treatment Considerations for Implant Rehabilitation

Ridge Reconstruction for Implant Placement

More than a fixed rehabilitation.

LOMAS / MONDEFIT ORTHODONTICS. The most innovative anchorage method for tooth correction

BICON DENTAL IMPLANTS

IMPLANT SYSTEM BRIDGE RESTORATIONS WITH THE CAMLOG CROWN AND. a perfect fit

Legacy3 System Overview Catalog. alog. 3.2mmD 3.7mmD 4.2mmD. Legacy mmD 5.2mmD 5.7mmD

Dental Implant Restoration

Manufacturer HEAD OFFICE. OSSTEM Germany GmbH. Mergenthalerallee MANUFACTURER

Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw

LOCATOR BAR ATTACHMENT SYSTEM

screw-retained crown using a PEEK temporary abutment

Restorative Manual Impression Transfer System

GS II Implant System. GS II Implant System. Catalog & Manual. Catalog & Manual MANUFACTURING DIVISION HEAD OFFICE

ATLANTIS abutments as individual as your patients

DENTAL IMPLANTS. Product Catalog SCIENCE OF AESTHETICS IMPLANTS

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

THE LOCATOR OVERDENTURE IMPLANT SYSTEM.

ANKYLOS. Syncone Concept. The Paradigm For Implant Supported Dentures. Redefining Success In Implant Dentistry

Prosthodontist s Perspective

B&B DENTAL IMPLANT COMPANY... 4 SURFACE TREATMENT... 6 IMPLANT PACKAGING... 8 IMPLANT LABELING... 9 CONEXA THE REVOLUTIONARY CONNECTION...

education Although demographic factors and growing patient awareness of the benefits of dental implants

Order of Treatment STEP-BY-STEP INSTRUCTIONS TO PLACE LOCATOR ATTACHMENTS

Procedures & Products Powered by Procera. All-on-4

Self-Aligning Lowest Profile

PROSTHETIC OPTIONS FOR NARROW NECK IMPLANTS. Straumann Narrow Neck

ALL-CERAMIC DENTAL IMPLANT SOLUTIONS

Implant systems Systematically perfect

IMPLANT DENTISTRY EXAM BANK

Smile Confidently With DIEM 2. Immediate Full Arch Rehabilitation

Navigator System For CT Guided Surgery Manual

Implants of high-performance ceramic. vk-lange :44 Uhr Seite 1. One-piece precision implant. Made in Germany

LOCATOR ROOT ATTACHMENT SYSTEM

Abutment fracture in a bridge supported by natural teeth and implants

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

ADA Insurance Codes for Laboratory Procedures:

Basic information on the surgical and prosthetic procedures. Straumann PURE Ceramic Implant

While the prosthetic rehabilitation of

INTRODUCTION. most popular stud attachment available to the dental profession to increase the retention of implant complete

Contact: Steve Hurson VP, R & D Nobel Biocare Savi Ranch Pkwy Yorba Linda, CA (714) steve.hurson@nobelbiocare.

Transcription:

ND NARROW DIAMETER implant

TABLE OF CONTENTS ND - NARROW DIAMETER implant Implant characteristics page 04 Dental implant page 05 Open Tray Impression Transfer page 06 Titanium Abutments page 07 O-Ball Abutments page 08 Reduced Surgical Kit page 09 Surgical Procedure page 09 Surgical kit components page 10 All of the materials produced by C-TECH follow a validated procedure, which includes surface treatment and packing as well, in conformity with European and international directives EN ISO 13485:2003/AC:207 and 93/42/EEC relative to medical devices. 2

Precision Dental Solutions C-Tech Implant is a dynamic company with aggressive growth, producing components and product lines primarily for dental implantology. International Presence With production and management based in Italy, C-Tech Implant is active in all major world markets and is distributed in over 20 countries. Scientific Research, Advanced technology, Simplification C-Tech Implant differentiates itself with attention to research and the application of high technology to its products, all while maintaining a simplicity of insertion and ease of use. C-Tech Implant incorporates the latest trends in implantology but providing for very practical surgical and prosthetic solutions aimed at offering the practitioner and the patient optimal results. High Quality Standards Kept Within Reach C-Tech Implant products are made to the highest standards governing the manufacturing and management of European medical and dental components. Up to date audits and certifications assure that these standards are vigilantly maintained. Training & Advice Dental professionals are assisted by the rich knowledge and experience of C-Tech Implant personnel and through C-Tech courses and training sessions. During these courses the professional is able to learn the latest methods of implant placement and reconstruction. Mission Statement The goal of C-Tech Implant is to provide the highest level of quality for technologically advanced products at reasonable prices in order to allow the dental practitioner to find solutions for the broadest range of patients. 3

ND Narrow Diameter implant Implant CHARACTERISTICS INTERNAL HEXAGON CONNECTION A reliable internal connection ensures a stable prosthetic platform that can carry the loads that will be encountered by the ND implant. COLLAR MICRO-GROOVING The specific micro-architecture of the implant collar increases the primary stability and facilitates the introduction of the implant. It promotes the soft tissue healing process and reduces the risk of bone loss at collar level. MAIN BODY THREADING Generously dimensioned main body threading provides surface area and stability despite the slenderness of the implant. MATERIAL The implant is made of medical grade 5 Titanium. The hardest alloy in use for dental implants, further ensuring the strength of this narrow dimensioned implant. 4

DENTAL IMPLANT ø3.0 ø3.0 ø3.0 ø2.3 ø2.3 ø2.3 9 mm 11 mm 13 mm ND-3009 ND-3011 ND-3013 Cover Screw Healing Abutments H2 H4 H6 ND-3008 0.8mm ND-3022 ND-3024 ND-3026 packaging Cover Screw ND-3008 0.8mm 5

ND NARROW DIAMETER implant OPEN TRAY IMPRESSION TRANSFER Intended use Open tray impression technique. ND-3040 Open tray Transfer includes screw 1 ND-3041 Impression Post Screw 2 ND-3042 Analog Characteristics - Simple; - Slender emergence profile accommodates space limitations; - Guide screw can be tightened either by hand or with the SCS screwdriver; - High precision impression components give an exact replica of the intraoral situation; - Clear-cut tactile response from the prosthetic connection verifies proper seating of components. Note Open tray impression procedure requires a custom-made tray with perforations. Impression posts are intended for single use only to ensure optimal fit and precise impression taking for each patient. STEP 1 Place the impression post accurately into the implant and hand-tighten the guide screw. 3 4 STEP 2 Make perforations in the custom-made impression tray (light cured resin) according to the individual situation so that the positioning screw of the impression post sticks out. STEP 3 Take the impression using an elastomeric impression material (polyvinyl siloxane or polyether rubber). STEP 4 Reposition and fix the analog in the impression using the screw. 6

titanium abutments Titanium ø 4 STRAIGHT ABUTMENTs INCLUDES SCREW ø 4 ø 4 ø 4 Titanium 15 ANGLED ABUTMENTs INCLUDES SCREW ø 4 ABUTMENT Screw H1 H2 H3 ND-3025-1 ND-3025-2 ND-3025-3 ND-1530 ND-5052HX Intended use Cement-retained restorations. Characteristics - Simple; - Less grinding necessary due to prepared mucosa margins; - Adaptation to natural soft tissue contour due to prepared mucosa margins in different heights (H1, H2, H3); - Oval shape resembles emergence profile of a natural tooth - Reliable; - Tapered connection (pure cone). Abutment and implant are linked so as to form a one-piece unit; - Extractor system allows easy abutment removal from the implant or the analog. STEP 1 Placement of the abutment in the model analog. STEP 2 Preparing the titanium abutment, modifying as required. STEP 3 Creation of the restoration. STEP 4 Cast the framework using the standard casting methods. STEP 5 Veneer the superstructure. 1 2 3 Note The cement margin must not be more than 2 mm below the mucosa. Use a new basal screw for the final insertion of the abutment. 4 5 7

ND NARROW DIAMETER implant O-BALL ABUTMENTs Intended use Removable dentures retained by implants in the mandible and maxilla. CT-9024S Swivel hex drivers Metal Housing MCH-1 Soft Retention MC-3005B O-ring (5 pieces) ND-5641 complete set LABORATORY ACCESSORIES H1 H2 H3 MCH-2 Medium Retention ND-5642 complete set MC-3005 O-ring (5 pieces) MCH-3 Hard Retention ND-5643 complete set Characteristics - Simple; - The clinical process for the ball attachment is quick and easy; - Functional; - The O-ring attachment is designed to virtually eliminate wear on the Ball Abutment and minimize the need for maintenance; - 3 different gingival heights; - 3 different O-ring resistances offering optimal retention for every individual situation. Reliable Dual retention for optimal abutmentdenture connection. Excellent long-term performance due to wear resistant components. STEP 1 Screw the spherical abutment into the implant using the torque ratchet (30 Ncm) and the driver (ref. CT-9024S). STEP 2 Rebase the overdenture according to the standard procedure. Complete SET Includes: MC-3013 Temp Cap MC-3014 Transfer Cap MC-3007 Collared Analog 1 2 1. O-Ring (Ref. MC-3005, MC-3005B) 1 piece 2. Metal Housing (Ref. MCH-2) 3. O-Ball Abutment (Ref. 5644, 5642, 5641) 8

REDUCED Surgical Kit REDUCED Surgical Kit includes: Locator drill CT-2020 2.0 external irrigation drill (Ø 2.0) CT-1720E 2.6 external irrigation drill ( Ø 2.6) 00075CUT Stopper (9mm) CT-stop07 Stopper (11 mm) CT-stop-08 Stopper (13 mm) CT-stop09 Drill extender ct-2000 1.25 swivel hex driver short CT-9024s 1.25 swivel hex driver long CT-9024 Implant ratchet driver short ND-E7001 Implant ratchet driver long ND-E7001l Torque wrench (50 Ncm) CT-8010 Paralleling pins qty 2 (1.6 mm- 2.0 mm) CT-9000 Depth Gauge (3.5 mm) CT-E9007 Depth Gauge (4.3 mm) CT-E9007 References: ND Sur.Kit.02 Reduced kit for Narrow platform line SURGICAL PROCEDURE For density D1/D2 For density D3/D4 ø3.0 CT-2020 Locator Drill CT-1720E 00075CUT ø3.0 CT-2020 Locator Drill CT-1720E ø2.3 ø2.3 9

ND NARROW DIAMETER implant Surgical Kit components Surgical Facilitators DRILL DEPTH STOPs Paralleling Pins CT-9003 3.5 mm 4.3mm CT-9000 1.6 mm 2.0mm CT-2000 Drill Extender CT-STOP07 Stop L.9 CT-STOP08 Stop L.11 CT-STOP09 Stop L.13 PROSTHETICS DRIVER CT-9025S Hex drivers CT-9025 Hex drivers CT-9019 Handpiece Latch CT-9024S Swivel hex drivers CT-9024 Swivel hex drivers CT-8051 Torque wrench attachments CT-8052 Torque wrench attachments ND IMPLANT DRIVERS Torque Wrench 50Ncm ND-E7001 Implant ratchet driver ND-E7001L Implant ratchet driver ND-E9040 Implant latch driver CT-8010 10

11

Via Santa Margherita al Colle n. 18-40136, Bologna - ITALY - Tel. +39 051.81.49.14 www.c-tech-implant.com - info@c-tech-implant.com