TriLock 1.5 Implants for the Phalanges



Similar documents
Elbow System 2.0, 2.8

Zimmer Small Fragment Universal Locking System. Surgical Technique

LCP Compact Foot/Compact Hand.

Technique Guide. Large Fragment LCP Instrument and Implant Set. Part of the Synthes locking compression plate (LCP) system.

MatrixNEURO CMF Matrix

PERIPROSTHETIC IMPLANTS

NCB Distal Femur System. Surgical Technique

MINI FRAGMENT SYSTEM. Instruments and implants for 1.5 mm, 2.0 mm, and 2.4 mm plate fixation PRODUCT OVERVIEW

VariAx Distal Radius Locking Plate System. Anatomical & Universal Volar Plates Dorsal Plates Fragment Specific Plates

Zimmer Periarticular Proximal Tibial Locking Plate

How To Fix A Radial Head Plate

Technique Guide. 3.5 mm and 4.5 mm Curved Locking Compression Plates (LCP). For minimally invasive osteosynthesis.

Surgical technique. End Cap for TEN. For axial stabilization and simultaneous protection of soft tissue.

Technique Guide. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System. Part of the Synthes variable angle locking compression plate (VA-LCP) system.

NCB Periprosthetic Femur Plate System. Surgical Technique

SURGICAL TECHNIQUE STEP BY STEP MDO 2.0. MODUS Mandible

NCB Proximal Humerus System. Surgical Technique

TwinFix Cannulated Compression Screw

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

V-TEK IVP System 2.7 System 4.0

Technique Guide. 2.4 mm LCP Distal Radius System. A comprehensive plating system to address a variety of fracture patterns.

Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

ACTIV ANKLE DISTAL AND DIAPHYSEAL FIBULA INNOVATION MEANS MOTION

Orthopedic Foot Instruments. Dedicated instruments for reconstructive foot surgery.

PATIENT SPECIFIC PLATES FOR MANDIBLE: CUSTOM MADE PLATES FOR TRAUMA AND RECONSTRUCTION

Technique Guide. Screw Removal Set. Instruments for removing Synthes screws.

Aesculap Veterinary Orthopaedics. Targon VET Interlocking Nail

CLAW II. Polyaxial Compression Plating System SURGIC A L T ECHNIQUE

BONE PRESERVATION STEM

Zimmer Periarticular Elbow Locking Plate System

LCP Superior Clavicle Plate. The anatomically precontoured fixation system with angular stability for clavicle shaft and lateral clavicle.

DARCO MRS. Locked Plating System for Reconstructive Rearfoot Surgery

OptiLock Periarticular Plating System For Proximal Tibial Fractures. Pre-Launch Surgical Technique

Wrist and Hand. Patient Information Guide to Bone Fracture, Bone Reconstruction and Bone Fusion: Fractures of the Wrist and Hand: Carpal bones

Titanium Wire with Barb and Needle. For canthal tendon procedures.

Malleolar fractures Anna Ekman, Lena Brauer

Technique Guide. DHS/DCS Dynamic Hip and Condylar Screw System. Designed to provide stable internal fixation.

More than a fixed rehabilitation.

Zimmer Natural Nail System. Cephalomedullary Nail Surgical Technique STANDARD

Foot and Ankle Technique Guide Proximal Inter-Phalangeal (PIP) Fusion

Straumann Bone Level Tapered Implant Peer-to-peer communication

NARROW DIAMETER implant

Universal Screw Removal System (USR)

Scout Vessel Guard. A cover for vessels during anterior lumbar spine surgery.

MatrixNEURO. The next generation cranial plating system.

Technique Guide. 4.5 mm LCP Proximal Femur Plates. Part of the Synthes Periarticular LCP Plating System.

Regular C/X Prosthetics. Prosthetics

How To Use A Phoenix Retrograde Femoral Nail

Oral and Maxillofacial Surgery. maxdrive. It s your turn

Scaphoid Non-union. Dr. Mandel Dr. Gyomorey. May 3 rd 2006

LCP Olecranon Plate. The anatomical fixation system with angular stability for olecranon and proximal ulnar fractures.

4052 Slimplicity Tech final_layout 1 6/29/15 3:29 PM Page 2 Surgical Technique

Implant Systems MAX LOGIC MONO. Today s name in tomorrow s implant technology

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

ARCS Pre-Implantology

Scaphoid Fracture of the Wrist

Achilles Tendon Repair, Operative Technique

Distal Radius Fractures. Lee W Hash, MD Affinity Orthopedics and Sports Medicine

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

Lentur Cable System. Surgical Technique

The information contained in this document is intended for healthcare professionals only.

ASSOCIATED LESIONS COMPLICATIONS OSTEOARTICULAR COMPLICATIONS

Fixing Dental Implant Component Failure and Fracture: Retrieving the Fractured Implant Abutment Screw. Charles A. Mastrovich, DDS

Aesculap. YASARGIL Aneurysm Clip System. From experienced hands for experienced hands! Aesculap Neurosurgery

LISS PLT. The less invasive stabilization system for proximal tibia fractures.

Knotilus TM. Anchor Instability Repair. Technique Guide

INJURIES OF THE HAND AND WRIST By Derya Dincer, M.D.

TABLE OF CONTENTS. Surgical Technique 2. Indications 4. Product Information Patient Positioning and Approach 2

DESS. Screws. Tijuana Ventas: (664) /95 For all major implant systems!!

Restoration Modular Cone Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Surgical Technique

Structural Integrity Analysis

Fractures around wrist

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

Module 5 Couplings. Version 2 ME, IIT Kharagpur

IFSSH Scientific Committee on. Wrist Biomechanics and Instability

Restoration of a screw retained single tooth restoration in the upper jaw with Thommen Titanium base abutment.

How To Design A 3D Print In Metal

Versa-Fx II Femoral Fixation System Surgical Techniques

VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty

Cranial/Neurosurgical Implants

INTRODUCTION Cerclage Cable Vs. Monofilament Wire

DHS/DCS System. Including LCP DHS and DHS Blade.

Standard Internal Hex

The Right Choice. Exeter. total hip system

Wrist Fractures. Wrist Defined: Carpal Bones Distal Radius Distal Ulna

Expert TN. Tibial Nail.

Expert LFN. Lateral Femoral Nail.

Fracture Fixation Devices Compression Hip Screws Cannulated/Bone Screws Bone Plates, Pins, Wires

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

GIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN.

Accolade. System. Brochure. Achieving Perfect Balance. Cemented and Cementless Femoral Hip System

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology. Surgical Technique

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

Selection & Use of Surgical Needles

the revo / mini-revo shoulder fixation system s u r g i c a l t e c h n i q u e

ANTERIOR CERVICAL DISCECTOMY AND FUSION. Basic Anatomical Landmarks: Anterior Cervical Spine

Foot Surgery Innovation in Forefoot Reconstruction BAROUK SCREW FRS SCREW TWISTOFF SCREW MEMORY STAPLE VARISATION STAPLE

Technique Guide. Orthopaedic Cable System. Cerclage solutions for general surgery.

Implants in your Laboratory: Abutment Design

Transcription:

P R O D U C T IN F O RM AT I O N TriLock 1.5 Implants for the Phalanges APTUS Hand

2 TriLock 1.5 Implants for the Phalanges TriLock 1.5 The Smallest Locking System Small, slender, strong Low profile and angular stable 1.5 TriLock hand plates and screws are a new addition to the APTUS Hand fixation system, expanding possible treatment options 1.5 TriLock implants set a new standard in the angular stable fracture fixation of the hand. Design and configuration of plates and screws have been optimized for the complex anatomy of the phalanges. 1.5 TriLock implants provide an increased support in comminuted and intra-articular fractures and fractures close to the joint, as well as improved stability in osteoporotic bone and arthrodeses. Clinical Benefits and Features Optimized Plate Geometry Stress distribution with torsional load; yellow-red coloring = increased stress 0.8 mm low profile plates Double bar on all straight plates for an increase of torsional stability by 20% Offset screw holes o to avoid screw collisions Conventional bar design o to increase rotational stability Variable angled locking (±15 ) in each plate hole Maximum Soft Tissue Protection Highly polished surface and rounded edges to reduce soft tissue irritation and adhesion New bar design Low overall profile Highly polished surface left, conventional surface right Medartis, APTUS, MODUS, TriLock, HexaDrive and SpeedTip are registered trademarks of Medartis AG, 4057 Basel, Switzerland.

TriLock 1.5 Implants for the Phalanges 3 Internal fixator for the phalanges Multidirectional (±15 ) and angular stable Highly polished surface and rounded edges Special Plate Designs Grid Plates High rotational stability, especially for comminuted fractures Straight hole arrangement on one end of the plate to position the plate as close to the joint as possible Offset hole arrangement to reduce the risk of screw collisions Double Row T-Plate For optimal reconstruction of articular fracture fragments and fractures close to the joint Ideal subchondral support of the articular surface Offset screw holes in the plate shaft Rotation Correction Plate The oblong hole is close to the joint to perform the osteotomy close to the meta-physeal area Offset screw holes in the plate shaft

4 TriLock 1.5 Implants for the Phalanges Technology, Screw Features Multidirectional and angular stable TriLock locking technology Technology Locking Locked Secure, angular stable locking of the screw in the plate o Spherical three-point wedge-locking o Friction locking through radial bracing of the screw head in the plate without additional tensioning components Screws can pivot freely by ± 15 in all directions for optimal positioning Intra-operative fine tuning capabilities TriLock screws can be re-locked in the same plate hole under individual angles up to three times Minimal screw head protrusion thanks to submerged locking contour No cold welding between plate and screws Secure locking of the TriLock screw TriLock screws can be re-locked up to three times Variable angle of ± 15 Minimal screw head protrusion

TriLock 1.5 Implants for the Phalanges 5 Screw Features Excellent self-holding properties HexaDrive screw head design o Secure connection between screw and screwdriver o Increased torque transmission o Optimal self-retaining mechanism Maximum soft tissue protection due to chamfered shape of the screw head without sharp edges Atraumatic tip prevents soft tissue irritation when inserting screws bicortically Tapered core diameter for increased torsional and tensile strength Precision cut thread profile for improved sharpness and self-tapping properties Double threaded for faster insertion of TriLock screws TiAl6V4 for improved strength Contact surface for screw retention Chamfered screw head design Atraumatic tips Contact surface for torque transmission Each plate hole can be used with 1.2/1.5 cortical (fixation) or 1.5 TriLock screws Double thread Minimal screw head design Tapered core diameter

6 TriLock 1.5 Implants for the Phalanges Ordering Information 1.5 TriLock Plates Material: Titanium (ASTM F67) Plate thickness: 0.8 mm 11 mm 9 mm 11 mm 19 mm 25 mm 23 mm 24 mm 9 mm 15 mm 21 mm 27 mm 17 mm A-4350.01 A-4350.14 A-4350.23 A-4350.41 A-4350.50 A-4350.56 A-4350.62 A-4350.66 A-4350.80 Art. No. Description Holes Piece per Pack A-4350.01 straight 4 1 A-4350.14 T 8 (3/5) 1 A-4350.23 rotation 6 (3/3) 1 A-4350.41 double row, T 9 (5/4) 1 A-4350.50 Grid, rectangular 4 (2x2) 1 A-4350.56 Grid, trapezoid 6 (3x2) 1 A-4350.62 Grid, trapezoid 8 (4x2) 1 A-4350.66 Grid, trapezoid 10 (5x2) 1 A-4350.80 Scaphoid 6 (3x2) 1 1.5 TriLock Screws, HexaDrive 4 Material: Titanium (ASTM F136) 2:1 Length Art. No Piece per Pack Art. No. Piece per Pack 4 mm A-5250.04/1 1 A-5250.04 5 5 mm A-5250.05/1 1 A-5250.05 5 6 mm A-5250.06/1 1 A-5250.06 5 7 mm A-5250.07/1 1 A-5250.07 5 8 mm A-5250.08/1 1 A-5250.08 5 9 mm A-5250.09/1 1 A-5250.09 5 10 mm A-5250.10/1 1 A-5250.10 5 11 mm A-5250.11/1 1 A-5250.11 5 12 mm A-5250.12/1 1 A-5250.12 5 13 mm A-5250.13/1 1 A-5250.13 5

TriLock 1.5 Implants for the Phalanges 7 Clinical Cases Case 1 Fracture of the Proximal Phalanges III and IV Preoperative X-rays 72 year old woman, 4 weeks after fall from a ladder with temporary K-wire fixation Osteosynthesis with two grid plates Postoperative X-rays Case 2 Fracture of the Proximal Phalanx V Preoperative X-rays 48 year old man after bicycle accident Left: Intraoperative view of the comminuted fracture zone Right: Intraoperative X-ray of the instable fracture site Postoperative X-rays Case 3 Scaphoid Nonunion Preoperative CT and X-ray Patient: male, 38 years old Nonunion of the scaphoid Intraoperative image, volar Left: Resection of the pseudarthrosis tissue Right: Pre-fixation of the plate with a suture Cases by courtesy of Prof. Schaefer, Basel, Switzerland and Dr. Ranft, Kiel, Germany X-rays, 10 weeks postoperative The union of the pseudarthrosis is well visible

HAND-01000001_v2 / 08.2013, Medartis AG, Switzerland. All technical data subject to alteration. HEADQUARTERS Medartis AG Hochbergerstrasse 60E 4057 Basel/Switzerland P +41 61 633 34 34 F +41 61 633 34 00 www.medartis.com SUBSIDIARIES Australia Austria France Germany Mexico New Zealand Poland UK USA For detailed information regarding our subsidiaries and distributors, please visit www.medartis.com