Zen House. A Case Study on Design, Construction and Cost/benefit Analysis of a High Performance Home. Presentation for Net Zero Networking & Exchange



Similar documents
research highlight Highly Energy Efficient Building Envelope Retrofits for Houses

2014 British Columbia Building Code Changes

BPC Green Builders. Green building for new and existing homes. Health Comfort Energy

Building Condition Assessment Report

How To Repair A Boat Landing Deck With A Boat Bed

Existing Housing Stock

Building Condition Assessment Report

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

BUILDING SAFETY UNIT

Foundation. Foundation

ECHO System for Basements

Home Energy Evaluation Report for Fritz Kreiss and Catherine McQueen

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

solutions & tips six Wise Energy Guide Building envelope solutions and simple tips AIR SEALING

ENERGY STAR Certified Homes, Version 3 Cost & Savings Estimates

IECC Compliance Guide for Homes in Virginia

2009 IECC Update. Scope. Content. International Energy Conservation Code

Renovating Your Basement

Selecting Energy-Efficient Windows

energy-saving checklist a guide for rental property owners

Superform Products Ltd.

Home Performance with ENERGY STAR. Evaluation Report

First Time Home Buyers Energy Efficiency Workshop Guide

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Vision Home Inspection

INCORPORATION BY REFERENCE OF INTERNATIONAL. (1) The Department of Labor and Industry adopts and incorporates by

Additions and Alterations

October 5, 2015 Dear Client,

Inspecting to a higher standard.

ROOFS, SNOW AND ICE DAMS

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.

Name of course: Residential Construction Site Management (RCSM) Level 1

Energy Analysis Pre-Build Report for:

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

Preparation for 2015 Residential Code Changes Discussion with Local Builders and Designers

ELIGIBLE REPAIR PROJECT PARAMETERS

This report presents the findings and recommendations of the assessment of energy use and

March 14, Installation of Bay, Bow and Garden Windows

Chapter 2: Foundations

How To Design An Hvac Design For A Stick Built Home

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

Exhibit IV Approved Measures List. Page 1 of 5

Comment Form on Proposed Gut Rehabilitation Alternatives

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure

bout your HOUSE before you start Renovating Your Basement Moisture Problems

BUILDING PERMIT SPECIFICATIONS

Crawford Inspection Services C.C.B. #

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Home Inspection Report

bout your house before you start Renovating Your Basement Moisture Problems

SECTION TABLE OF CONTENTS. H Proposed Material, Product or Equipment Substitution Request

Summit Series Single Section and Double Section Homes

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

Self-Home Inspection Checklist

City of St. Charles Basement Finish or Remodel

) SIGNIFICANT CHANGES INCLUDING CODE COMMENTARY

Key energy-efficient features of your new home

Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings

Performance of 8 Passive House Envelopes in Cold Climates

FLORIDA SOLAR ENERGY CENTER

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

PERFORMANCE OF SIDE-BY-SIDE SOUTH TEXAS HOMES Isolating the Contribution of Spray Polyurethane Foam Insulation

Does Wall Township require an inspection by the building department on resale of a home?

HomeSpec REPORT SUMMARY

4 Installation Requirements

Home Energy Evaluation Report

Best Basement Water Management Practices

Glossary of Heating, Ventilation and Air Conditioning Terms

Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders

Thermal Imaging for Home Inspectors

GUIDE TO WINDOW REPAIR & REPLACEMENT FOR HISTORIC PROPERTIES

Energy Star Case Study on Blue Hills. Introduction

HVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

about your house Before You Start Renovating Your Basement Moisture Problems Figure 1 Moisture problems to solve

Uniform Construction Code (UCC) Manufactured Homes. Modular Homes. Building Permit Application Package

Asphalt Shingle Application Requirements

In accordance with the Department of Labor and Industry s statute , Subd. 11,

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

RULING OF THE MINISTER OF MUNICIPAL AFFAIRS AND HOUSING

INSTALLATION OF A BAY WINDOW

Uncovering Myths and Opportunities of Advanced Building Envelope Technologies: BIPV, Roofing and Windows

Before You Start an Energy Efficiency Retrofit The Building Envelope

Building Permit Application

Pre-Drywall Inspection Report

Nominal Life Expectancy for Building Components

Energy Efficiency in Buildings

Home inspectors are not mold inspectors, however they do inspect for defects that

Energy Code Compliance With SIPs. Frank Baker, PFB Corporation Don Ferrier, Ferrier Custom Homes

Residential Duct Systems for New and Retrofit Homes

Transcription:

Zen House A Case Study on Design, Construction and Cost/benefit Analysis of a High Performance Home Presentation for Net Zero Networking & Exchange CHBA Net Zero Energy Housing Council May 13, 2015 Ottawa by: Arthur LO Insightful Healthy Homes Inc.

Design A tailored-designed and custom-built 2 ½ storeys single family home -finished floor area 3942 sq. ft. plus 740 sq. ft. heated crawl space House owners requirements: highest energy performance possible with a healthy and comfortable living environment, and is albeit built on the cost within their budget limit. economically viable but practical interior finishings, home appliances, and lighting and plumbing fixtures. Large room in their dream home which would be used for occasional meditation gatherings the exterior look of the house should reflect their religious beliefs.

Curb Appeal The house is designed for ZEN style: The aesthetic appeal of the house demonstrates the ideals and insights of ZEN -balance, stability, tranquility, and nature. symmetrical front of the house represents balance. lower-and upper-storeysare proportioned to achieve stability Clear and simple exterior finishes show tranquility Natural stone steps on front stairs and two round columns in solid wood at the porch highlight the natural theme. Feature rocks on white gravel on both sides of front stair emphasize the ZEN style.

Design for Energy Efficiency Day-lighting South facing clerestory windows near top of family room in upper floor bring in day lighting to the central part of upper floor Sun light through the clerestory windows shines on the white walls and reflects through the lower windows on the upper floor into the Great Room, bringing daylight to main floor

Natural ventilation In shoulder seasons, outdoor air temperature provide the occupants with thermal comfort solely by natural ventilation through the house. The south-facing windows in the Great Room on main floor, the windows in the Family Room on upper floor, and the motorized window at top of the stairs will facilitate free air flow to enhance natural ventilation. This natural ventilation is activated by opening the motorized window at top of the stair (the highest operable window in the house) by use of a remote

Building Envelope and Systems Foundation: 3 TYPE 2 EPS RIGID INSULATION BOARD SA WATERPROOFING MEMBRANE (AB) 6 CONCRETE IN INSULATED CONCRETE FORM, ICF ½ DRYWALL LOW-PERMEANCE LOW-VOC WATER-BASED PAINT, <30 ng/(pa.s.m^2) (VB) EFFECTIVE R-VALUE = 30.5

Base Slab FLOOR FINISHING 4 THICK CONCRETE SLAB SEALED 6 mil POLY (AB & VB) 3 TYPE 2 EPS RIGID INSULATION BOARD MIN. 4 GRAVEL COMPACTED SOIL BASE EFFECTIVE R-VALUE = 12.0

Wall assembly: ¾ lstucco ¾ AIR SPACE 1X3 TREATED STRAPPING 2 R8 ROXUL COMFORT BOARD AIR-TIGHT TYVEK HOUSE WRAP (AB) ½ PLYWOOD WALL SHEATHING 2X6 STUDS @24 O.C. WITH DOUBLE TOP PLATE AND 2 STUDS CORNER 5.5 R22 BATT INSULATION ½ 5DRYWALL LOW-PERMEANCE LOW-VOC WATER- BASED PAINT, <30 ng/(pa.s.m^2) (VB) EFFECTIVE R-VALUE = 25.7

Ceiling/Roof: ROOF WITH FLAT CEILING ASPHALT SHINGLE ROOFING TILES ROOFING MEMBRANE ½ OROOF SHEATHING ENGINEERING TRUSSES @ 24 O.C. 14 BLOWN CELLOUSE INSULATION R42 SEALED & GASKETED 5/8 FIRE RATED AIR-TIGHT DRYWALL (AB) LOW-PERMEANCE LOW-VOC WATER-BASED PAINT, <30 ng/(pa.s.m^2) (VB) EFFECTIVE R-VALUE = 51 ROOF WITH VAULTED CEILING ASPHALT SHINGLE ROOFING TILES ROOFING MEMBRANE ½ OROOF SHEATHING 2X4 STRAPPING @ 16 O.C. 11 7/8 TJI JOISTS 12 R40 BATT INSULATION SEALED & GASKETED 5/8 FIRE RATED AIR-TIGHT DRYWALL (AB) LOW-PERMEANCE LOW-VOC WATER- BASED PAINT, <30 ng/(pa.s.m^2) (VB) EFFECTIVE R-VALUE = 37

Windows and Doors FIXED, AWNING, CASEMENT WINDOWS OR FRENCH DOORS VINYL FRAME TRIPLE GLAZING LOW-E COATING ARGON GAS INFILL INSULATED SPACER

Heating and cooling High efficient cold climate air source heat pump (Mitsubishi Zuba-Central, heating HSPF 9.4, cooling EER 12.0 SEER 15.00) Forced air system Two zones control (one for basement and the other for main and upper floors) to better control the room temperatures at different thermal conditions.

Air Filter A MERV 13 bag filter is installed in the HVAC duct system -see the metal box holding the bag filter at the return side of air handler. Air handler fan will run continuously to circulate air inside the house while passing air through the filter to achieve the best air quality.

Hot Water High efficient gas water boiler with indirect tank (IBC VFC 45 225, 95% AFUE)

Ventilation Eneready 2000 HRV Whisper Power grills with PoshTimezone switches at all bathrooms HRV supply integrated with the heating supply ducts. HRV exhaust in dedicated HRV exhaust ducts All HRV ducts were tested on site before drywall to ensure air-tightness.

Lighting 70% of lighting fixtures in LED light 20% of lighting fixtures in CFL Motion-sensor control for exterior lights Appliances and other electrical equipment All new home electric appliances, including fridge, dishwasher, range, hood fan, washer and dryer in are Energy Star rating.

Construction Foundation Fabric footing forms save time and materials in footing construction. prevent common moisture problems in basement due to wicked up moisture by capillary action from footing through concrete wall into basement living spaces. act as air barrier under footing connecting the 6 mil poly (air barrier) underneath base slab with the waterproofing membrane (air barrier) on the outside face of foundation wall.

Foundation Insulated concrete form (ICF) with 2.25 thick EPS on both sides of the 6 concrete core save both time and material in foundation wall construction. higher insulation and perform better moisture-proofing than normal basement wall construction As an energy conservation measure, a layer of 3 EPS insulation board was installed on the waterproofing membrane in full height on the outside face of foundation wall.

Unlike normal construction, the house wrap has to be sealed and taped at all joints between each sheet of house wrap

The house wrap has to be sealed and taped between the house wrap and other members of the building envelope, such as doors, windows, and all penetrations through the wall e.g. water pipe and wires.

The house wrap was installed on the wall sheathing using staples with plastic caps. This could minimize the number of staples used, thus minimizing the number of penetration through the air barrier, while holding the house wrap securely in place.

This photo shows different elements and stages of construction at the exterior wall: 1) sealed house wrap at top right corner, 2) exterior insulation board at top center and 3) rain screen strapping as lower level.

Windows installation Because of the additional 2 thick exterior insulation, the weatherproof and air seal work in window installation for the Zen House are different from normal construction. The differences are: Addition of metal flashing at window sill Bigger metal flashing at window head Extra wood trims around the windows

Window Installation Procedure Step 1 exterior wall framing completed with appropriate window rough opening

Step 2 apply a 4 wide flashing below the window sill (do not staple the bottom each of the flashing)

Step 3 install a treated wood block below window sill (to support the metal flashing of window sill)

Step 4 tape the corners, window sill, wooden block

Step 5 apply trim flashings around the rough opening Step 5 apply trim flashings around the rough opening

Step 6 install the window

Step 7 install the metal head flashing and apply tape along the top edge of the flashing

Step 8 install the metal window sill flashing below window and on the wooden block

Step 9 install house wrap around the window, tape and seal all joints

Step 10 install the 2 insulation board on the house wrap

Step 11 install rain screen strapping

Step 12 Install trims around the window Step 13 add another metal flashing on top of top window trim (diagram not shown)

Ceiling under roof House wrap MUST be fully supported on both faces during its servicing life in order to ensure its long term integrity as air barrier. At ceiling under roof, house wrap (a flexible membrane) is only supported by roofing trusses or joists (at 24 or 16 on center), -no full support at its top surface Therefore, house wrap is not suitable as air barrier at ceiling under roof. (It is used as air barrier on the vertical surfaces of the building envelope only). Rigid material, e.g. taped drywall, which has the strength to ensure long term integrity is more suitable as air barrier at ceiling under roof.

To ensure the continuity of air barrier, the house wrap at top of exterior wall was wrapped from outside passing between two top plates to the inside of the wall and was then well taped along its edge on the internal face of the lower top plate.

Gasket was stapled along the taped end of house wrap on the top plate of exterior walls under roof. Gasket was also installed along the top plate of all interior walls under roof. Drywall boards were installed on the ceilings and walls with close space drywall screws along the top edges of drywall. With the taping at all drywall corners, the drywall and gaskets act together as air barrier sealing off air leakage to/from the open space in roof.

Air Test Post drywall test To study air seal performance of the house wrap All drywall was installed and taped, all openings through the building envelope, such as venting ducts and hood fans, were closed. The air test would show the air seal performance of the house wrap at walls, taped drywall at ceiling under roof, poly under base slab, and all windows and doors. Test result: 0.71 ACH @ 50Pa and 50.53 in^2 ELA @ 10 Pa.

Final test The final air test was conducted after the completion of the house. Under the new R2000 requirements, all openings cannot be closed during the air test. These openings in Zen House include two hood fans, the intake and exhaust ducts of HRV, two dryer vent ducts, one hot water boiler vent duct. Test result: 0.9 ACH @ 50 Pa and 61.77 in^2 ELA @ 10 Pa The result indicated the effect of the above openings on the overall air tightness of the house.

Energy Conservation Measures (ECM) 2 broader approaches Provide higher insulation and better air-tightness of the building to reduce heat loss, reducing the energy required to keep the building in a livable condition Increase the efficiency of mechanical systems, lighting and home appliances, so that they can use less energy to perform their functions.

These two broader approaches can be carried out through 9 energy conservation measures (ECM) 1. Increase insulation of the foundation wall 2. Increase insulation of base slab 3. Increase insulation to above grade exterior wall 4. Increase insulation of roof 5. Upgrade windows and doors 6. Improve air-tightness of the house 7. Upgrade the efficiency of heating and cooling system 8. Upgrade the efficiency of domestic hot water system 9. Use higher efficient lighting and home appliances

ECMs adopted in Zen House The energy performance of a particular ECM is found by analyzing the Baseline house with the additional of that ECM using energy simulation software HOT2000 The additional cost for ECMs is based on the actual expenditure record from the Zen House project

ECM #1 Location: Foundation wall Baseline construction: 8 concrete wall plus 2x4 R12 furring wall inside Upgrade: Use ICF wall and add 3 EPS insulation on outside face of wall Annual energy saving: 2626.87 kwh Additional cost: $4,494.31

ECM #2 Location: Foundation base slab Baseline construction: 2 wide 3 EPS insulation under slab along foundation walls Upgrade: 3 EPS insulation under whole base slab Annual energy saving: 471.12 kwh Additional cost: $1,240.00 Note: many municipalities have required insulation under whole base slab if radiant floor heating is installed. In this case, this is not an ECM

ECM #3 Location: Exterior wall above grade Baseline construction: 2x6 R22 wall Upgrade: Add 2 mineral wool semi-rigid insulation board on outside of exterior walls. Annual energy saving: 4004.65 kwh Additional cost: $13,070.77

ECM #4 Location: Roof Baseline construction: R40 for both sflatand sloping ceiling roofs Upgrade: No upgrade is adopted in Zen House due to high cost Annual energy saving: 0 kwh Additional cost: $0

ECM #5 Location: All windows Baseline construction: Double glazing, clear glass, air infill, vinyl frame Upgrade: triple glazing, low-e coating, argon gas infill, insulated spacer, vinyl frame Annual energy saving: 2164.88 kwh Additional cost: $2,500.00

ECM #6 Location: Building envelope Baseline construction: normal air-tight construction, ACH = 4.55 ACH @ 50 Pa Upgrade: high performance air-tight construction, ACH = 0.9 ACH @ 50Pa (actual air test result of ZEN House) Annual energy saving: 6950.49 kwh Additional cost: $3,539.44

ECM #7 Location: Heating System Baseline equipment: high efficient (90%) condensing gas furnace Upgrade: cold climate air source heat pump, heating HSPF 9.4, cooling, EER 12.0, SEER 15.00 Annual energy saving: 20047.49 kwh Additional cost: $5,400.00

ECM #8 Location: Domestic hot water system Baseline equipment: medium efficient gas hot water tank Upgrade: condensing high efficient (90%) hot water boiler Annual energy saving: 2183.10 kwh Additional cost: $2,471.00

ECM #9 Location: Lighting and appliances Baseline equipment: normal lighting and appliances Upgrade: 70% LED lighting, 20% CFL lighting, energy star appliances and water saving plumbing fixtures Annual energy saving: 3626.24 kwh Additional cost: $1,000.00

ECM Cost-benefit Analysis - Initial Cost ECM Additional cost Annual energy saved (kwh) cost to save 1 kwh ICFplus 3 EPS to foundation wall $4,494.31 2626.87 $1.71 3" EPS under base slab $1,240.00 471.12 $2.63 2" exterior Roxul to exterior wall $13,070.77 4004.65 $3.26 Roof insulation from R40 to R50 NA NA NA Windows - Triple glazing $2,500.00 2164.88 $1.15 Air-tightness - to R2000 standard $3,539.44 6950.49 $0.51 Cold weather air source heat pump $5,400.00 20047.49 $0.27 High efficient hot water tank $2,471.00 2183.10 $1.13 Energy efficient lighting& appliances $1,000.00 3626.24 $0.28

ECM has different service life Future electricity rate forecast based on BC Hydro 2011 IRP Technical Advisory Committee, Integrated Resource Plan, Long- Term Rate Forecast 2010 BC Hydro Residential Rate, Tier 1: $0.067 Assumed inflation 2.1% Use Equivalent-Annual-Annuity Approach

ECM Cost-benefit Analysis Service Life ECM Service life IRR Equivalent-Annual- Annuity (cents) ICF plus 3 EPS to foundation wall 50 5% 5.35 3" EPS under base slab 50 3% 2.42 2" exterior Roxul to exterior wall 50 2% 0.41 Roof insulation from R40 to R50 50 NA NA Windows - Triple glazing 30 6% 3.29 Air-tightness - to R2000 standard 40 15% 7.66 Cold weather air source heat pump 25 27% 6.56 High efficient hot water tank 25 5% 2.18 Energy efficient lighting& appliances 10 23% 4.01

Annual Green House Gas Emission (tonne): 6.686 (11.688) ECM Service life GHG Reduction in Service Life Additional cost Add. Cost to save 1 tonne GHG ICFplus 3 EPS to foundation wall 50 24.60 $4,494.31 $182.70 3" EPS under base slab 50 4.45 $1,240.00 $278.65 2" exterior Roxulto exterior wall 50 37.50 $13,070.77 $348.55 Roof insulation from R40 to R50 50 NA NA NA Windows - Triple glazing 30 12.18 $2,500.00 $205.25 Air-tightness -to R2000 standard 40 40.28 $3,539.44 $87.87 Cold weather air source heat pump 25 23.68 $5,400.00 $228.09 High efficient hot water tank 25 9.78 $2,471.00 $252.79 Energy efficient lighting& appliances 10 15.98 $1,000.00 $62.58

Energy Performance of Zen House Site Energy in Heating Mode Only Estimated Annual Space Heating Energy Consumption (kwh): 3043.05 (27969.07) Ventilator Electrical Consumption: Heating Hours (kwh): 1322.78 (512.04) Estimated Annual DHW Heating Energy Consumption (kwh): 3327.21 (7800.57) ESTIMATED ANNUAL SPACE + DHW ENERGY CONSUMPTION (kwh): 7693.04 (36281.68) LESS 79% Eneguide Rating: 88 Note: Figures in bracket are Baseline House results

Annual Estimated Energy Consumption by Devices Site Energy in Heating Mode Only kwh Heating A/C HRV + fan DHW Appliance Total Baseline 27489.09 0.00 1005.52 7800.64 8759.86 45055.12 Zen House 2933.63 0.00 1920.19 3327.22 6838.20 15019.25 Zen House to baseline percentage 11% 0% 191% 43% 78% 33%

Baseline Heating A/C HRV + fan DHW Appliance Zen House

Estimated Annual Fuel Consumption Costs Site Energy in Heating Mode Only Electricity Gas Total Saving Saving in Percentage Baseline $796.83 $1,240.49 $2,037.32 Zen House $935.16 $265.82 $1,200.98 $836.34 41%

Financial A analysis Total additional Cost for Energy Upgrade = $33,715.52 Mortgage for $33,715.52 Mortgage rate: 4.74% Amortization: 25 years Monthly payment = $192.02 Annual payment = $2,304.29 Compare with Annual Fuel Consumption Costs: Heating mode only: $836.34 Heat and Cooling mode: $1,030.72

Discussion Primary energy Cost effect due to fuel Air-conditioning Energy bill saving vs mortgage payment for additional cost for energy upgrade