Features Direct mass flow monitoring eliminates need for separate temperature and pressure inputs. Accuracy +/- 1% of reading plus 0.

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

QuadraTherm 640i/780i HIGH ACCURACY : FOUR-SENSOR : MASS FLOW METER

Side-Trak 830/840. Process Gas Mass Flow Meters and Controllers.

Thermatel Model TA1 Mass Flow Transmitter

Thermal Mass Flow Meter (Series MST)

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Thermatel Enhanced Model TA2 Thermal Mass Flow Meter

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Typical Aluminum GFM Mass Flow Meter

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

For Multi-Parameter Meters see mvx

COMBIMASS. Technical Data COMBIMASS eco-bio +

The Unique Accelabar Flow Meter

FCI ST75 Series Flow Meters

Micro Motion 3098 Gas Specific Gravity Meter

Plastic tube flowmeters Series PT/PS

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electronic Flow Switches

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

In-Line Electronic Flow Switches

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

Micro Motion Model D and DL Coriolis Flow and Density Meters

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

DigitalFlow GF868. Panametrics Flare Gas Mass Ultrasonic Flowmeter with Extended Performance Range. GE Sensing & Inspection Technologies.

PIEZOMETER AIRFLOW MEASURING RING

OPTIMASS 6000 Technical Datasheet

SITRANS F flowmeters SITRANS F M

Mass Flow Meters & Controllers

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Sanitary Type Electronic Flow Switches

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

3DLevelScanner II TECHNICAL DATA SHEET

Model 111 Mass Flow Instruments

T U R B I N E G A S M E T E R

How To Use A Ds340 (Dsp)

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD

Electromagnetic Flow Meter

FCI M180 Series: Custom Engineered Flow and Level Sensors for OEM Applications

Regards from the Team at Rheology Solutions.

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

TELEDYNE HASTINGS INSTRUMENTS

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

O C M III. Open Channel Flow Monitor

How To Use A Flowmeter

VSO MAX HP High Flow Proportional Valve

OPTIMASS 1400 Technical Datasheet

Power Supply and Cabling Options. SmartTrak 100/101/140

Digital inductive conductivity transmitter

2.12. page Products for Explosion hazardous Environment

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

Series DFMT Digital Paddlewheel Flowmeter

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

General Purpose ph/orp Sensors

Compact pressure switch Flameproof enclosure Ex d Model PCA

Scraper Passage Indicator. Electrical Indicator. Features

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Sierra S-Series Smart Interface Software User Manual

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Take total control of your HVAC system with cost-saving flow and thermal energy meters

Galvanic Parts Per Million Dissolved Oxygen Systems

Centro-Matic Automatic Lubrication Systems System Controls

BB-18 Black Body High Vacuum System Technical Description

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

S300 Series Dust Monitors

Technical Data Sheet. 3DLevelScanner

Self Purging Liquid Trap (SPLT ) User s Manual

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MG Transmitter with Digital Output.

Laminar Flow Elements

! WARNING. Before using product, read and understand instructions.

Morrison Bros. Co. General Product Specifications

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

StackFlowMaster FPD581, FPD583 and FPD585 Stack gas metering systems

9000 Series Accelerometers Specifications

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

APT3200 SMART PRESSURE TRANSMITTER. Application Areas: For Gauge And Absolute Pressure Measurement

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

F ox W hi t e Paper. Reduce Energy Costs and Enhance Emissions Monitoring Systems

The L&J Engineering Model MCG 1500SFI Servo Gauge

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

James M. Pleasants Company

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Rosemount 333 HART Tri-Loop

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Transcription:

Immersible Thermal Gas Mass Flow Meter Features n Direct mass flow monitoring eliminates need for separate temperature and pressure inputs n Accuracy +/- 1% of reading plus 0.5% of full scale n Patented Dry-Sense technology eliminates sensor drift n State-of-the-art calibration facility insures a highly accurate calibration that matches the application n Field validation of meter electronics and sensor resistance verifies flow meter performance n One-second response to changes in flow rate n FM, CSA, PED, ATEX and GOST R/RTN certified for hazardous areas n CE approved n High temperature option to 750 F (400 C) available n Multipoint options available n Integrated self-cleaning purge option available for dirty flows now and high pressure hot taps available n Optional HART, Modbus and Profibus DP available, Foundation Fieldbus (pending) SteelMass 640S Description S ierra Instruments SteelMass Model 640S immersible thermal mass flow meter is designed for the toughest industrial gas flow measurement applications. The versatile microprocessor-based transmitter integrates the functions of flow measurement, flow-range adjustment, meter validation and diagnostics in either a probe-mounted or remote housing. Mass flow rate and totalized flow, as well as other configuration variables, are displayed on the optional 2 x 12 CD display. The programmable transmitter is easily configured via an RS-232 communication port and Sierra s Smart Interface software, or via the display and magnetic switches on the instrument. Sierra's state-of-the-art calibration facility insures that the calibration will match the application, and our patented Dry-Sense thermal sensor insures the Model 640S will hold this calibration over time. Sierra s Smart Interface software guides you through a procedure to fully validate instrument performance, thus field-verifying meter functionality. The meter is available with a variety of input power, output signal, mounting and packaging options. www.sierrainstruments.com The information contained herein is subject to change without notice.

Hazardous-Area ocation Enclosure Dimensional Specifications Tables Compression Fitting Side View (E2) Compression Fitting Front View (E2) ength Chart (Compressions Fittings) Code X 2 3/4-inch NPT, Typ..54 (13.7) Flange Mounting Side View (E2) 3/4-inch NPT, Typ. 1-inch ANSI, B16.5 150 lb Flange.54 (13.7) C X Remote Mount Junction Box Side View (E4) 1/2-inch NPT, Typ. 5.70 1.6 (40.6).54 (13.7) X Remote Mount Side View (E3, ATEX only) X.75 (19.05)φ Flange Mounting Front View (E2) 2.5 (63.5).75 (19.05)φ Remote Mount Junction Box Front View (E4) Per Customer Cable ength Requirement, 200 Feet Maximum.75 (19.05)φ Remote Mount Front View (E3, ATEX only) 06 6.0 7.5 (152.4) (190.5) 09 9.0 10.5 (228.6) (266.7) 13 13.0 1 (330.2) (368.3) 18 18.0 19.5 (457.2) (495.3) 24 24.0 25.5 (609.6) (647.7) 36 36.0 37.5 (914.4) (952.5) ength Chart (Flange Mounting) Code X 06 6.0 9.0 (152.4) (228.6) 09 9.0 12.0 (228.6) (304.8) 13 13.0 16.0 (330.2) (406.4) 18 18.0 21.0 (457.2) (533.4) 24 24.0 27.0 (609.6) (685.8) 36 36.0 39.0 (914.4) (990.6) ength Chart (Remote Mount Junction Box) Code X 06 6.0 7.5 (152.4) (190.5) 09 9.0 10.5 (228.6) (266.7) 13 13.0 1 (330.2) (368.3) 18 18.0 19.5 (457.2) (495.3) 24 24.0 25.5 (609.6) (647.7) 36 36.0 37.5 (914.4) (952.5) Mounting Holes for Remote Bracket.50 (12.7) 3.00 (76.20) 1.5 (38) 3.0 (76) Per Customer Cable ength Requirement, 200 Feet Maximum Per Customer Cable ength Requirement, 200 Feet Maximum X.31 φ (7.87), 2P All dimensions are inches. Millimeters are in parentheses. All drawings have a +/-.25-inch (6.4 mm) tolerance. Certified drawings are available on request.

Hazardous-Area ocation Enclosure Dimensional Specifications Remote Rear Bracket Mounted Electronics Remote Side Bracket Mounted Electronics Tables ength Chart (NEMA 4X) Code X 3 06 6.0 7.25 (152.4) (184.1) 09 9.0 10.25 (228.6) (260.3) 13 13.0 14.25 (330.2) (361.9) 18 18.0 19.25 (457.2) (488.9) 24 24.0 25.25 (609.6) (641.3) 36 36.0 37.25 (980.4) (946.1) 3.0 (76.2) 10.07 (255.8) 7.25 (184.2) 5.0 (127) NEMA 4X Dimensional Specifications SEF-CEANING PURGE OPTION Maximum process pressure 100 Psi Maximum process temperature 500 F. Max pressure purge air: 150 Psi Process connection Purge air 1/4 NPTF Wetted Process Parts: all 316SS The purge gas must be clean and dry. Do not use a liquid to clean the sensor inline The purge system is only available with E4 and E2 housings The purge system is NOT available with FM, ATEX or CSA approval or the high temperature option The purge system is NOT available with digital communication products. Warning: During the purge cycle there will be a high flow over the sensor. This will drive the output of the flow meter to the maximum flow (Output will be 20-26 ma (load dependent) during the purge. Insure that this temporally high output does not effect any alarms or process control systems. Operation: This is not a continous flow of air, but a blast purge option. The purge nozzle creates a jet stream wich blows deposits from the sensors. The frequency and intensity of the purge is determined by the end user. It can be done with a suitable manual, pneumatic or electric valve (Solenoid). It is also possible to control the purge system automatically (f.i. timer, PC or HMI). Note: There is a check valve built Inside the flow meter to prevent the return flow of process gasses into the purge system. Replacement of this valve can only take place in the factory. Note: Only a 24 VDC power input is available when ordering an internal purge option.

ow Pressure Hot Tap to 150 psig (10 barg) Side View Variables = Nominal Probe ength D = Duct O.D. C = Duct I.D. T = Height of Threadolet or Customer Provided Weldolet R = Restraint Cable ength Formula 12 + D/2 + T So must be equal or greater than 12-inches plus the height of the Threadolet plus half the duct O.D. R = D/2 + T + 8.8 D C 0.75 (19.05)φ Duct High Pressure Hot Tap to 230 psig (15.8 barg) Flow Inward C M2 Threadolet or Customer Supplied 1-inch Weldolet T 1-inch NPT Hex Nipple, 2P 1-inch NPT Ball Valve 3.3 (83.8) 4.3 (109.2) 10.8 (274.3) 4.0 (101.6) 6.5 (165.1) Restraint Cable, ength=r 1-inch NPT Hot Tap Packing Gland Probe 1.0 (25.4) All dimensions are inches. Millimeters are in parentheses. All drawings have a +/-.25-inch (6.4 mm) tolerance. Certified drawings are available on request. 0.7 (17.8) 7.7 (195.6) 4 Unobstructed Flow Requirements Select an installation site that will minimize possible distortion in the flow profile. Valves, elbows, control valves and other piping components may cause flow disturbances. Check your specific piping condition against the examples shown below. In order to achieve accurate and repeatable performance install the flow meter using the recommended number of straight run pipe diameters upstream and downstream of the sensor. If you cannot meet these requirements please refer to the Flat-Trak Model 780S with flow conditioning plates (flow conditioning plates reduce upstream requirements to as little as 2 diameters. Example - Upstream Requirements (A) 1 15D 2 20D 3 40D 4 15D 5 30D 6 40D Example - Downstream Requirements (B) 1 5D 2 5D 3 10D 4 5D 5 10D 6 5D

Performance Specifications Accuracy of Point Velocity +/- 1% of reading + 0.5% of full scale. Note: Overall accuracy of HT meters may be de-rated due to temperature and velocity conditions. Repeatability +/- 0.2% of full scale Temperature Coefficient +/- 0.02% of reading per F within +/- 50 F of customer specified conditions +/- 0.03% of reading per F within +/- 50 F to 100 F of customer specified conditions +/- 0.04% of reading per C within +/- 25 C of customer specified conditions +/- 0.06% of reading per C within +/- 25 C to 50 C of customer specified conditions Pressure Coefficient.02% per psi for air, consult factory for other gases Response Time One second to 63% of final velocity value Operating Specifications Gases Most gases compatible with 316 stainless steel Hastalloy available Gas Pressure (2 limitations) Mechanical design pressure: Compression fittings: 500 psig (34 barg) 1-inch 150 lb flange (-40 to 250 F): 185 psig (12.8 barg) ow Pressure Hot Tap: 150 psig (10 barg) High Pressure Hot Tap: 275 psig (18 barg) Output Signal inear 0 5 VDC or 0-10 VDC, 1000 ohms minimum load resistance or inear 4 20 ma proportional to mass flow rate, 700 ohms maximum resistance power supply dependent User-selectable: Active non-galvanically separated or Passive galvanically separated (loop power required) Alarms Hard contact user-adjustable high and low Dead band adjustable with Smart Interface software Relay ratings: Maximum 400 VDC or VAC (peak), 140 ma Displays Alphanumeric 2 x 12 digit backlit CD Adjustable variables via on-board switches (password protected) or with Smart Interface software Adjustable variables: Full scale (50 to 100 %) Time Response (1 to 7 seconds) Correction factor setting (0.5 to 5) Zero and span High and low alarm settings Totalizer Seven digits (9,999,999) in engineering units Resettable by software, on-board switches or external magnet Software Smart Interface Windows -based software Minimum 8 MB of RAM, preferred 16 MB of RAM RS-232 communication Additional features: Alarm dead band adjustment Zero cut-off adjustment inearization adjustment Save / oad configurations Flow meter validation Physical Specifications 5 Pressure Drop Negligible for pipes three inches in diameter or larger Gas & Ambient Temperature Gas............. -40 F to 350 F (-40 C to 177 C) Gas dependent. Ambient......... -40 F to 120 F (-40 C to 50 C) eak Integrity 5 x 10-9 cc/sec of helium maximum Power Requirements 18 to 30 VDC (regulated), 625 ma maximum 100 to 240 VAC, 50/60 Hz, 15 watts maximum 625 ma maximum operating current at 24 VDC and full scale flow Maximum in rush current of 2 Amps at 24 VDC Consult factory for other conditions High Temperature Option Up to 750 F (400 C) air only; consult fatory for other gases Digital Communications Options Pulse (not available with E2-NR) Modbus RTU (not available with P3 option ) Profibus DP (available E2/E4-P2 configuration only) HART universal commands (available E2/E4-P2 configuration only) Foundation Fieldbus (available E2/E4-P2 configuration only) pending Viton, Neoprene, Kalrez, and Teflon are registered trademarks of Dupont. Windows and Excel are registered trademark of Microsoft. Wetted Materials 316 stainless steel Enclosure Hazardous-Area ocation Enclosure (IP66) or NEMA 4X (IP65) Both are powder-coated cast aluminum Electrical Connections Two 3/4 inch NPT: Hazardous-Area ocation Enclosure (IP66) One 1/2 inch NPT: NEMA 4X Enclosure (IP65) Mounting (optional) ANSI 1-inch 150 lb flange 3/4-inch tube compression fitting with 1-inch male NPT Hot tap systems Certifications CE (All enclosures) CSA (Explosion proof for Class I, Division 1, Groups B, C, D) ATEX ( II 2 GD Ex d IIC T6... T2; IP 66 T70 C... T280 C ) FM (Explosion proof for Class I, Division 1, Groups B, C, D; dust-ignition proof for Class II, III, Division 1, Groups E, F, G) IP65, NEMA 4X T6-40 C to 70 C ambient Chinese pattern approval GOST R/RTN (1ExdIICT6...T2)

Ordering the 640S 6 Features Options Parent - - - - - - - - - - - - - 1 2 3 4 5 6 7 8 1 2 3 4 5 Instructions: To order a 640S please fill in each number block by selecting the codes from the corresponding features below and following pages. Parent Number 640S 640S MultiTrak SteelMass Industrial Insertion Mass Flow Meter. 18-30 VDC or 100-240VAC input power with 3/4-inch diameter 316SS probe. Includes "Smart Electronics" with PC configuration software. Calibration temperatures up to 350 F (176 C) and pressure to 500 psig (3 barg). HT option to 750 F (400 C) available (contact factory). CE, FM, CSA, ATEX approvals. inear 0-5 VDC, 0-10 VDC or 4-20 ma output signals. ifetime warranty on Fast Response (FR) sensor) Multi-Point System: Consists of multiple 640S probes calibrated in NMPS and Modbus communication and a electronics system that communicates with the 640S probes, converts the signals to any desired units (Mass flow) and averages the flow measured by the 640S probes. oad factors can be adjusted in the electronics. The standard system is designed for 4 x 640S probes, but consult factory for more or less points. (Product formerly known as Multi-Trak Model 670S) Feature 1: Approvals NAA Non-agency approved meter ATEX 640S with ll 2 GD Ex d IIC T2...T6 ATEX Approval. Requires E2 or E3 enclosure. E3 required for probe lengths greater than 13 inches. Maximum probe length is 36 inch (92 cm). Note: ATEX units have circuit energy limitations that limit maximum flows to approx 50% of non-atex units. Consult gas tables for actual values FM 640S with FM Approval. Requires E2 or E4 enclosure. Maximum probe length is 72 inches (2 m) CSA 640S with CSA Approval. Requires E2 or E4 enclosure. Maximum probe length is 72 inches (2 m) Feature 2: Probe ength 06 6 inch (15 cm) 09 9 inch (23 cm) 13 13 inch (33 cm) 18 18 inch (46 cm) 24 36 24 inch (61 cm) 36 inch (92 cm) ( ) Specify length in parentheses. Maximum probe length 72 inches (2 m). Minimum length 6 inches (15 cm) ( ) M5 Probe with 1 inch, class 150 Flange Specify length in parentheses. Include M5 option Diagram with ADS M9 High pressure hot-tap retractor kit. Kit includes 21-inch probe assembly, retractor assembly with hand crank, packing gland probe seal with a 2-inch ANSI class 150 process connection. Not available with ATEX, FM, CSA or EN enclosure. Insertion depth 0-21 inches. Probe length not required. Feature 3: Mounting Accessories M0 None. Customer to supply own mounting hardware M1 Compression fitting 3/4-inch with 1-inch NPT Male M2 Threadolet 1-inch Female NPT M1-M2 ( ) Compression fitting plus Threadolet. 3/4-inch probe feed through by 1-male NPT. Threads into 1-inch Female NPT, which is welded to the pipe. Specify pipe O.D. in Parenthesis. We strongly advise to purchase this as a set, since we've seen non compatible NPT threads in the past. M3 Flat duct bracket. 3/4-inch tube compression fitting M4 ( ) M8 ( ) M15 Curved duct bracket. 3/4-inch tube compression fitting. Specify duct O.D. in parentheses ow pressure hot tap. Includes ball valve and packing gland. Specify duct O.D. in parentheses. Maximum 150 psig (10.3 barg) Quick removal Hot-Tap. Includes ball valve and compression fitting. Rated for 40 psig (2.8 barg) Feature 4: Electronics Enclosure E2 Hazardous-area location enclosure (IP66) Mounted directly on probe E3 ( ) Remote hazardous-area location enclosure (IP66). Specify cable length in parenthesis. Maximum 200 feet (61m) Hazardous-Area ocation Enclosure (IP66) housing mounted up to 200 feet (61m) from flow body; includes strain relief on end of probe and mounting bracket. E4 ( ) Remote Hazardous-Area ocation Enclosure (IP66) with Junction Box. Specify cable length in parenthesis. Maximum 200 feet (61m) Hazardous-area location enclosure (IP66) housing mounted up to 200 feet (61m) from flow body; includes (IP66) junction box mounted on probe and mounting bracket for remote electronics enclosure. EN2 NEMA 4X (IP65) enclosure. Mounted directly on probe EN4 ( ) Remote NEMA 4X (IP65) Enclosure with Junction Box. Specify cable length in parenthesis. Maximum 200 feet (61m) Mounted up to 200 feet (61m) away from the probe with junction box mounted on probe. Includes remote electronics enclosure mounting bracket and 1/2-inch Female NPT connection.

Ordering the 640S 7 Feature 5: Input Power P2 18 30 VDC P3 100 240 VAC. Not available with EN enclosures Feature 6: Output V1 0-5 VDC, linear V3 0-10 VDC, linear V4 4-20 ma, linear Feature 7: Display NR DD Feature 8: Gas 0 Air No readout 1 Argon 2 Carbon dioxide 3 Chlorine 1 4 Digester gas 2 5 Digester gas 1, 2 6 Helium 7 Hydrogen 8 Methane 9 Methane1 10 Nitrogen 11 Oxygen1 12 Propane 13 Propane1 Digital display 2 x 12 digit, backlit, CD display indicates flow rate and totalized mass in engineering units. Simplifies configuration settings and provides system status information 99 Other--Consult Factory Note: 1 Correlation calibration - consult Product Data Sheet for accuracy. 2 Digester Gas = 60% Methane, Carbon Dioxide by mass (specify for other ratios). Option 4: Certificates MC Material certificates--us Mill certs on all wetted parts CC Certificate of conformance NACE NACE certificate for sour gas T eak test certificate PT Pressure test certificate Option 1 : Digital Communications Pulse Totalizer pulse output (1 Hz max, not available with E2-NR) MB Modbus communications (not available with P3 option) FF Foundation Fieldbus output with full device description (DD) (available E2/ E4 P2 config only) DP Profibus DP output (available E2/ E4 P2 config only) HART HART universal commands (available E2/ E4 P2 config only) Note: No agency approvals available with MB, FF, DP, HART Option 2: Purge PURGE Includes non-return valve, tube and purge nozzle option for cleaning of probe tips. 30-120 psig (2.1-8.3 barg) external compressed air source required. Uses 1/4-inch compression fitting on purge tube process connection. Available with E2 only. Not available with HT option (Contact factory in this case for external purge solution). Does not include on/off valve. NAA only. NOTE: Only a 24 VDC power input is available when ordering an internal purge option. Option 3: High Temperature HT HT option to 750 F (400 C). Requires remote (E4 or EN4). Contact factory for probe length (limited lengths available) Option 5: O2 Cleaning O2C O2 Cleaning. Meters up to 4 inches (DN100). Includes certification. Product cleaned for O2 service. Inspected with Ultra-Violet light only, double-bagged prior to shipment.

Sierra Instruments, North America 5 Harris Court, Building Monterey, California (800) 866-0200 (831) 373-0200 Fax (831) 373-4402 www.sierrainstruments.com Sierra Instruments, Europe Bijlmansweid 2 1934RE Egmond aan den Hoef The Netherlands +31 72 5071400 Fax: +31 72 5071401 Sierra Instruments, Asia Second Floor Building 5 Senpu Industrial park 25 Hangdu Road Hangtou Town Pu Dong New District Shanghai, P.R. China 200122 +8621 5879 8521/22 Fax: +8621 5879 8586 640S I.1 12/15