How to transform you into a radialist: tips and tricks
|
|
|
- Bartholomew Hoover
- 10 years ago
- Views:
Transcription
1 How to transform you into a radialist: tips and tricks Part II Caroline Frangos a, Stéphane Noble b a Hôpital de La Tour, Meyrin, Genève b Hôpitaux Universitaires de Genève Summary The transradial approach increases patient comfort and reduces vascular complications and major bleeding. Although modern equipment has been improved and catheter sizes reduced, there remain specific technical challenges in the practice of the transradial approach. Indeed, the transradial approach requires a longer learning curve than transfemoral access, but the transradial challenges are usually overcome with experience. Nowadays, in view of its benefits, there is no longer any justification for ignoring the transradial approach, the patient s preferred access route for percutaneous coronary interventions. In this paper we highlight five rules which will transform you into a radialist and provide valuable tips and tricks. Key words: transradial approach; coronary angiography; percutaneous coronary angioplasty; radial artery spasm; anatomical variations As the radial artery (RA) is superficial and readily compressed, the transradial approach (TRA) reduces vascular complications and bleeding, major causes of morbidity and mortality, especially for patients undergoing percutaneous coronary interventions (PCI). However, TRA requires a longer learning curve than the transfemoral approach (TFA) due to specific technical challenges that are usually overcome with experience. After more than 1000 TRA procedures each, we felt it necessary to share some tips and tricks which will transform you into a TRA adept. Blood supply to the hand is provided by two palmar arches. The superficial palmar arch and the deeper palmar arch, which are important arterial connections between their major sources, the ulnar artery and the radial artery. The RA is superficial and easily palpable. No major nerves or veins are located near the RA, thus minimising the risk of injury to these structures. Conversely, the ulnar artery is deeper and close to the ulnar nerve. Rule N 1: be comfortable for radial artery puncture Patient selection is described elsewhere [1]. RA puncture requires a palpable artery and a delicate touch. During the early phase of TRA experience, RA puncture is a frequent cause of failure. The groin should always be prepared in case of emergency crossover to TFA. Arm setup The arm can be placed on a board anchored under the shoulder at an 80 angle from the body (fig. 1) or, according to the operator s preference, directly in a support positioned along the body. A folded sheet or roll of gauze is usually placed under the wrist to achieve hyperextension. In our opinion the former setup provides a better wrist position for RA puncture, especially in overweight patients. In this setup the arm is positioned in a support along the body once the sheath has been inserted. The operator elevates the table to its full height to perform the puncture in a comfortable standing position. Some operators prefer to be seated. Funding / potential competing interests: No financial support and no other potential conflict of interest relevant to this article were reported. Five rules to transform you into a radialist Correspondence: Dr. Stephane Noble Département des Spécialités Unité de cardiologie interventionnelle Hôpitaux Universitaires de Genève CH-1211 Genève 4 stephane.noble[at]hcuge.ch Cardiovascular Medicine 2011;14(11):
2 Local anaesthesia Adequate local anaesthesia with subcutaneous xylocaine 1 2% (0.5 to 1.5 ml) with a 25-gauge short needle (2 ml syringe) minimises pain and helps prevent RA spasm. Infiltration of the RA should be avoided since it will increase RA spasm. Delicate massage of the wrist facilitates distribution of the xylocaine. In a series of patients with radial spasm due to failed attempts at RA puncture [3], the investigators compared three different options: the wait and see attitude, administration of 400 mcg of sublingual nitroglycerin or injection of 1 ml (200 mcg/ml) of nitroglycerin solution on the medial and lateral aspect of the RA location. The mean time for the pulse to reappear was 18 ± 5 min, 8 ± 1 min and 3 ± 1 min respectively and subsequently the rate of successful radial cannulaneedle selection and techniques for puncture Two puncture techniques exist: the double-wall puncture technique with a sheath-covered needle, and the single-wall puncture technique with a bare needle, in line with the technique used by 60% of operators worldwide [2]. The choice of needle is a matter of operator s preference. The RA should be punctured at a angle, 1 2 cm proximal to the radial styloid process. It Figure 1 Arm setup for puncture. A. Arm placed on a board anchored under the shoulder at an 80 degree angle from the body. A folded sheet is placed under the wrist. No venous catheter should be inserted in the area of the radial artery or on the hand. Ideally the venous catheter should be inserted on the contralateral arm. Arrow showing the support used to place the arm along the body. B. Ready for anaesthesia and puncture. C. Puncture in a standing position with the table elevated to its full height. D. The sheath has been inserted and the arm is positioned in a support along the body. is important to obtain a good backflow before introducing the guide wire. Once the wire is inserted, a small skin incision at the base of the needle may facilitate sheath insertion, though, depending on the sheath used, it is not always necessary. Rule N 2: make the patient comfortable It is essential that the patient is comfortable and relaxed to prevent RA spasm (stress induces catecholamine release and increases the risk of spasm). The procedural steps are explained to the patient by the operator to minimise patient anxiety. Premedication Anxiety relievers are useful to relax the patient, especially with inexperienced operators. In experienced hands, premedication need be administered only in anxious patients. Arm support The arm and wrist must be placed in a support (fig. 1), along the body, allowing the operator to work in similar conditions to TFA (comfort and distance to the X-ray generator). Cardiovascular Medicine 2011;14(11):
3 tion was 72%, 90% and 100%. Bertrand et al. refined the technique by routinely mixing xylocaine 2% and nitroglycerin in the same syringe as the local anaesthesia [4]. sheath size In cases where the RA is small, a 5 French (F) sheath is preferable, especially when the procedure is expected to be a diagnostic coronary angiogram or the probability of angioplasty is low. If necessary, the angioplasty can be performed via a 5F guide catheter or sheathless guide catheter (Sheathless Eaucath, Asahi Intecc, Japan), or the sheath can be exchanged for a 6F. Prevention of radial artery spasm With respect to spasm prevention, success on the first attempt always achieves the best results. In addition to premedication and local anaesthesia, intraarterial administration of vasodilatators is essential. Various spasmolytic cocktails have been tried [5]. Verapamil is the most commonly used vasodilatator, being administered directly after sheath insertion in a dose of 2.5 up to 5.0 mg (diluted up to 10 ml with saline). The patient should be warned of a transient burning sensation in the forearm during injection. Mixing verapamil with blood (blood buffers reduce verapamil acidity) and slow injection reduce this unpleasant sensation. Use of hydrophilic sheaths has been shown to reduce pain and subsequently spasm. Moreover, use of smaller catheters (5F vs 6F) in the presence of a small RA further reduces the incidence of spasm. Thanks to automatic injectors which overcome the previous limitations of 5F catheters from the days of manual injection, the vast majority of radialists routinely perform diagnostic coronary angiograms with 5F catheters regardless of the RA calibre and without impairment of image quality. With experience the procedure takes less time and fewer catheter manipulations are necessary, resulting in a marked decrease in RA spasm incidence. Table 1 Most frequent upper limb artery anatomical variations in an angiographic series of 2211 consecutive patients. High bifurcation of the RA (8.3%) Hypoplasia (7.7%) Tortuosity (3.8%) Stenosis (1.7%) Loop (0.8%) Retrooesophageal origin of the right subclavian artery or arteria lusoria (0.45%). Rule N 3: use the right wire Standard 175-cm long J-shaped wire is the workhorse, as it progresses towards the arm easily and without resistance in the majority of cases. Nevertheless, navigation through the brachial and subclavian arteries may sometimes be challenging, due to vessel loops, tortuosities or anatomical variations. The rate of upper limb anatomical variations ranges between 10 and 23% in different series [10] (table 1). Below we describe commonly encountered situations and how to overcome difficulties. Resistance advancing the wire or catheter. Spasm or tortuosity, mostly at the level of the elbow, or the presence of a remnant artery (fig. 2) are the most common reason for resistance. The wire should never be advanced aggressively or against resistance. Instead, radiobrachial injection of diluted contrast should be performed to assess anatomy. The table can be rotated for easier visualisation of the arm. Figure 2 Anatomical variations. Anatomical variations: a wire can be introduced into a remnant artery with a small arterial diameter (type 3) but failure to advance any catheter is the rule and the incidence of spasm is very high in such anatomy. Prevention of radial artery occlusion (RAo) RA occlusion is an infrequent (3% to 10%) and clinically silent complication of TR catheterisation (in properly selected cases). Unfortunately its occurrence precludes any future TRA. There is evidence that up to half of RA occlusions are recanalised at 30-day followup [6]. Heparin has been shown to significantly reduce the incidence of RAO and a clear relationship exists between the heparin dose and the rate of RAO [7] IU heparin (or 70 IU/kg) is recommended, and most operators use an intraarterial route. Other potential predictive factors of RAO are procedural time, operators in their learning curve, arterial diameter ratio to the sheath and compression time and pressure [8, 9]. Cardiovascular Medicine 2011;14(11):
4 Radial artery tortuosity or loop A hydrophilic J-shaped wire (Glidewire, Terumo, Japan) can cross any tortuosity or loop in the vast majority of cases, but must always be introduced under fluoroscopic guidance to ensure proper progress into the arm and ascending aorta without engaging small branches (risk of perforation) and avoid major head and neck vessels (vertebral and carotid arteries). The loop is usually straightened once crossed by the hydrophilic wire or the catheter (fig. 3). In severe radial artery loop, when the hydrophilic wire fails, a regular hydrophilic coronary angioplasty wire can be used under fluoroscopic guidance. subclavian artery tortuosity or loop A hydrophilic J-shaped wire is the best choice in this situation. To overcome the difficulties of catheter manipulations once the subclavian level loop is crossed, a stiff wire (eg. Supracore, Abbott vascular) may help to introduce the catheter into the ascending aorta and rotate it for ostium cannulation. In extreme cases right coronary artery (RCA) cannulation may require a 5F guide catheter in association with a stiff wire; this does not impair image quality. exchanging catheters Catheter exchange should be performed over a wire to avoid losing access (risk of spasm). A long ex- change wire (220 cm or 260 cm) or a 175 cm regular wire can be used. With the latter, if the wire is on the aortic cusp at the beginning of the exchange, loss of control of approximately 10 cm of the wire is not an issue. When the ascending aorta is difficult to reach, a long exchange wire should be used. use of respiration A long history of high blood pressure, especially in octogenarians, may be associated with considerable tortuosities of the brachiocephalic trunk and subclavian arteries, which may make the procedure more complex. Deep inspiration helps to reach the ascending aorta by modifying the angulation of the brachiocephalic trunk. Left anterior 30º projection is the optimal view for assessment of the ascending aorta as the different portions of the aorta are not superposed. However, when the wire repeatedly enters the descending aorta despite deep inspiration and the use of a JR4 oriented anteriorly, angiographic assessment is the next step. A retrooesophageal origin of the right subclavian artery (arteria lusoria), a rare anatomical variation, may become apparent, rendering the procedure by right TRA highly complex, whereas left TRA is easier. Usually when catheters reach the ascending aorta they fall into the right cusp, and engagement of the left cusp requires careful withdrawal until the tip retracts Figure 3 Radial loop. A. Large loop on the radial artery. Arrow showing a very small remnant artery. B. Loop straightened after insertion of a terumo wire and a 5F diagnostic catheter. Data supplement showing insertion of the wire. Cardiovascular Medicine 2011;14(11):
5 Routine diagnostic catheter selection For diagnostic angiography, 5F Judkins left (JL) 3.5 and Judkins right (JR) 4.0 remain the most commonly used catheter types according to the First International Transradial Practice Survey [2], allowing a cannulation success rate of over 90%. Dedicated single catheters to cannulate left and right systems have been developed (eg. Tiger [Terumo] and Kimny [Boston Scientific Corp, USA] catheters). Few operators use speover the right aortic leaflet and moves into the left coronary cusp. Gentle inspiration may also facilitate movement into the left coronary cusp and help selective left system cannulation. Rule N 4: choose the right catheter Selection of the catheter is important if good quality images are to be obtained and to ensure good support if PCI is necessary. Figure 4 Barbeau guide catheter in a case of complex RCA PCI. A. Antero-posterior and cranial projection showing a tortuous and diffusely diseased RCA (diagnostic JR 4 catheter). B. RCA PCI performed with a 6F Barbeau guide catheter: after predilatation, positioning of a mm Xience Prime drug-eluting stent (arrows) over a BMW wire. The Barbeau guide catheter provides a good backup support since it is well-seated against the posterior wall of the aorta (arrow head). A second wire (Buddy wire technique) is also used to improve stent delivery. C. Insertion of a second Xience Prime stent ( mm) proximal to the first one (arrows). D. Final result. Cardiovascular Medicine 2011;14(11):
6 cial curves such as Amplatz left and right or multipurpose, and TRA pioneers have developed their own dedicated catheters (eg. Barbeau and Fajadet). Routine guide catheter selection For left coronary interventions, the majority of operators use extra backup guide catheters, the most popular being the EBU 3.5 (Medtronic Inc) or XB 3.5 (Cordis Corporation), since the JL guide catheter does not offer adequate support by TRA. For RCA PCI, JR is the most commonly used catheter. When anatomical difficulties with the RCA require better support, some operators use the Amplatz left. We rarely use this guide catheter (in 1% of our RCA PCI), because we believe the benefits of this catheter are outweighed by a higher risk of ostium dissection. Indeed, the Barbeau (Cordis Corporation, Johnson and Johnson, USA) is our guide catheter of choice, especially for vertical RCA takeoff and when more backup support is required (fig. 4). Rule N 5: limit compression time Since the artery is superficial, haemostasis is simple and easy to control. After removing the catheter over a 0.035, the sheath is gently pulled back. Forceful pulling back of the sheath may result in avulsion of the RA [11]. Although a compressive bandage (simple gauze Figure 5 Sheathless catheter characteristics. The sheathless 7.5F guide catheter (Asahi Intecc) has an inner diameter equivalent to a 7F conventional guide catheter and an outer diameter (2.49 mm) inferior to a 6F sheath (2.62 mm). Similarly, the 6.5F guide catheter has an inner diameter equivalent to a 6F conventional guide catheter and an outer diameter (2.16 mm) smaller than a 5F sheath (OD 2.29 mm). Cardiovascular Medicine 2011;14(11):
7 and elastic bandage) is an option used in developing countries, the insertion of a compression device (TR- Band, Hemoband, Radistop, Easy radial, Radstat) is recommended. The airbag -based bracelet (TR-Band, Terumo) with progressive deflation is the most commonly used dedicated radial compression device. To reduce RA occlusion, compression time should ideally be limited to 3 hours (with progressive release). The concept of patent RA haemostasis has recently been promoted (RA pulse assessment by plethysmography) to reduce the incidence of RAO, Pancholy et al. having shown a 75% RAO rate reduction at 30 days when applying patent haemostasis under guided RA compression [12]. The amount of air inflated in the TR-band usually varies between 13 to 18 ml. A Spanish study [9] showed that when the amount of air inflated was guided by mean arterial pressure (mean air volume of 8.8 ml), significantly fewer RAO were observed than Figure 6 Telescoping technique. A. Picture showing the wide gap between an wire and the 6F guide catheter. B. Picture illustrating the telescoping technique with a long (125 cm) 5F Judkins right diagnostic catheter introduced through a 6F guide catheter. C. Zoom on the distal end of the 5F diagnostic catheter. The gap from the wire is undoubtedly smaller. Table 2 Preferred route for each pattern of CABG. Type of CABG Preferred route Catheter suggested LIMA LRA Internal mammary curve SVG to LCA (originating from the left side of ascending aorta) LRA easier JR4 AL1, AL2 LCB SVG to RCA (originating from the right side of ascending aorta) LRA easier Multipurpose JR4 RCB AL1, AL2 LIMA and RIMA Femoral Double radial approach RRA LCA = left coronary artery; LIMA = left internal mammary artery; LRA = left radial artery; RCA = right coronary artery; RIMA = right internal mammary artery; RRA = right radial artery; SVG = saphenous vein graft. Cardiovascular Medicine 2011;14(11):
8 Figure 7 Haematoma classification (published with permission of Dr O. Bertrand, Laval Hospital, Quebec; Modified from Bertrand et al. Circulation 2006; 114(24): Table realised for standardisation of post-procedural haematoma assessement in the EASY study. Grade I II III IV V incidence 6% <3% <2% 0.1% <0.01% Definition Local hematoma Hematoma with Forearm hematoma Hematoma and Ischemic superficial moderate and muscular muscular threat muscular infiltration, below infiltration (compartment infiltration the elbow extending above syndrome) the elbow Treatment Analgesia Analgesia Analgesia Analgesia Consider Additional Additional Additional Bracelet Additional Bracelet sugery Bracelet Bracelet Local ice Local ice Local ice Local ice Inflated BP cuff Inflated BP cuff Notes Inform physician Inform physician Inform physician STAT call to physician Remarks: Control blood pressure (BP): importance of pain management Consider interruption of any anticoagulation and/or antiplatelet infusion Follow forearm and arm diameters to evaluate requirement for additionnal bracelet and/or BP cuff inflation Additional bracelet can be placed alongside artery anatomy Ice cubes in a plastic bag or washclosh are placed on the hematoma Finger O 2 saturation can be monitored during inflated blood pressure cuff To infalte blood pressure cuff, select a pressure of 20 mmhg < systolic pressure and deflate every 15 minutes After bracelet removal, use «Velpeau bandage» around forearm/arm for a few hours to maintain mild positive pressure when the device was routinely inflated with 15 ml air. In our experience, 13 ml air is sufficient in the vast majority of cases. How to manage specific situations Radial artery spasm The loss of RA pulse is not only frustrating, but may render TRA nearly impossible. Spasm may occur either during puncture (increased risk with repeated punctures) or diagnostic and therapeutic procedures (usually related to excessive catheter manipulation or multiple catheter exchange). RA spasm is generally associated with severe pain in the arm, justifying the administration of anxiety relievers and/or sedation. RA spasm during the procedure If spasm occurs during coronary angiography, administration of anxiety relievers and a calcium-channel blocker (verapamil 2.5 mg) and/or intraarterial nitroglycerin (100 to 250 ug) is helpful. Smaller size diagnostic catheters (i.e, 4F instead of 5 or 6F) are a valid option. When a 6F or 7F guide catheter is needed, two options are available if catheter insertion is difficult or painful: Sheathless catheter Recently, sheathless hydrophilic guide catheters have emerged as an alternative when the RA is too small or in cases of spasm preventing the use of a 6F guide catheter. Sheathless guide catheters have an outer diameter (OD) more than 1F smaller than traditional guide catheters making 6F PCI in frail women, or complex Cardiovascular Medicine 2011;14(11):
9 PCI [13 14] requiring a 7F guide catheter possible (fig. 5). When using these sheathless catheters, be aware that the dilator is radiotransparent and hence the dilator should be held in place once the radioopaque sheathless guide reaches the aortic cross, to prevent any potential damage to the aortic cusps. Telescopic technique (mother and child technique). This involves advancing a 6 or 7F guide catheter over a long 5F diagnostic catheter (125 cm JR 4). The 5F long diagnostic catheter serves as a dilator and reduces the mismatch between the catheter and wire (fig. 6). It has the advantage of allowing the use of any guide catheters you are accustomed to. On the other hand, the sheathless system described above is hydrophilic and moves forward very easily. extreme spasm Extreme radial or brachial artery spasm may prevent the removal of the catheter or sheath. On very rare occasions when anxiety relievers are not enough, deep sedation/general anaesthesia may be required to relieve spasm and allow catheter removal. Small calibre radial artery RA is often smaller in women but this does not preclude radial access. Spasm is more likely to occur in the presence of small RA and in women, and thus special attention must be paid to anxiety, pain relief and puncture accuracy. Operators may be restricted to smaller conventional guide catheters to perform PCI, or they can use sheathless guide catheters or the telescoping technique. Moreover, contralateral RA should be checked as asymmetry of RA diameter may be present. A left radial approach can be adopted if left RA diameter seems significantly larger and hand collaterals testing is favourable. Patients with coronary artery bypass grafts (CABG) TRA can be successfully used for patients with CABG. However, transradial cannulation of the saphenous vein grafts (SVG) may be technically demanding. The preferred route for each pattern of CABG is described in table 2. TRA catheterisation of left internal mammary grafts (IMA) is easier than TFA. In cases of double IMA, catheter advancement into the contralateral subclavian artery has to overcome multiple angulations and high friction in the absence of adequate support. It is therefore reasonable to favour TFA in patients with bilateral IMA grafts even though successful contralateral access (preferably by right TRA) to the IMA have been reported [15]. Double TRA may be considered in cases of inappropriate TFA access. Local bleeding and haematoma Vascular complications with TRA are extremely rare. Nevertheless, haematoma of the arm proximal to the elbow (non-access site related but secondary to small branch perforation or arterial laceration) must be promptly detected to ensure rapid management. Bertrand et al. [16] graded forearm haematomas according to size with a 5 grade classification and provided the appropriate strategy to manage every grade (fig. 7). In cases of large or growing haematoma, a blood pressure cuff should be rapidly inflated at the site of the haematoma at 20 mm Hg below the systolic pressure for 15 minutes, with repeated inflation if needed. This manœuvre allows sealing of the perforation, softening of the haematoma, and prevention of further swelling and the subsequent risk of compartment syndrome. In cases of late management, extensive arm haematoma may cause compartment syndrome, a very serious but fortunately very rare complication of TRA occurring in less than 0.01%. Surgical decompression may be required in this clinical situation. Interestingly, when perforation of the RA occurs during a procedure, the best treatment may be to continue the procedure. When a catheter can cross and then tamponade the area of concern, the perforation will often seal by the end of the intervention. Left transradial approach The vast majority of operators (90%) use the right TRA as the initial access site since it allows the procedure to be performed with similar comfort to TFA (the right arm is positioned along the patient s body). Left TRA can be used as a routine access or as an alternative to right TRA when unsuccessful. Left TRA is similar to TFA with respect to catheter selection and manipulation, and enables easier cannulation of the ostia than right TRA. Furthermore, in patients with left IMA graft catheterisation of the IMA is easier. Patient preparation is similar to that for right TRA with a board under the left shoulder and the wrist in hyperextension. After obtaining left RA access, the patient s left arm is brought across the chest onto the abdomen (left wrist close to the right groin area). A cushion is placed under the left shoulder to ensure arm stability and patient comfort. For left TRA, JL (3.5 or 4.0) and JR (4.0) catheters are the first choice. Progression of the wire can be difficult through the elbow due to the half-bent arm and temporarily straightening the arm can be helpful. Sometimes use of a hydrophilic wire under fluoroscopic guidance may be necessary. Once the catheter is introduced into the brachial artery, the arm is repositioned on the abdomen. Cardiovascular Medicine 2011;14(11):
10 In obese patients and particularly for shorter operators, left TRA might be technically more demanding since the operator has to lean over the patient to reach the left wrist. Notably, since the operator stands closer to the X-ray generator in left TRA, there were some concerns regarding higher operator radiation exposure after left TRA than after right TRA. However this was not observed in the TALENT Dosimetric Substudy [17] which compared both TRA in a randomised trial including 770 patients in each group. Conclusion Specific technical challenges related to TRA are most often overcome with experience. When difficulties are encountered at any stage of wire progression, performance of an angiographic assessment is highly recommended. Understanding the problem will prevent complications (dissection and perforation) and allow successful management. Knowing the anatomic variations and the technical recommendations to overcome such situations will undoubtedly help new TRA converts in achieving success. References 1 Frangos C, Noble S. How to transform you into a radialist: literature review. Part I. Cardiovascular Medicine. 2011;14(10): Bertrand OF, Rao SV, Pancholy S, et al. Transradial approach for coronary angiography and interventions. Results of the first international transradial practice survey. J Am Coll Cardiol Intv. 2010;3: Pancholy SB, Coppola J, Patel T. Subcutaneous administration of nitroglycerin to facilitate radial artery cannulation. Catheter Cardiovasc Interv. 2006;68: Bertrand OF, Larose E, Rodes-Cabau J. Sub-cutaneous nitroglycerin: good example of the KISS rule! Letter to the Editor Catheter Cardiovasc Interv. 2006;70: Varenne O, Jégou A, Cohen R, et al. Prevention of arterial spasm during percutaneous coronary interventions through radial artery: The SPASM study. Cathet Cardiovasc Interv. 2006;68: Stella PR, Kiemeneij F, Laarman GJ, et al. Incidence and outcome of radial artery occlusion following transradial artery coronary angioplasty. Catheter Cardiovasc Diagn. 1997;40: Spaulding C, Lefèvre T, Funk F. Left radial approach for coronary angiography: results from a prospective study. Cathet Cardiovasc Diagn. 1996;39: Dahm JB, Vogelgesang D, Hummel A, et al. A randomized trial of 5 vs 6 French transradial percutaneous coronary interventions. Catheter Cardiovasc Interv. 2002;57: Cubero JM, Lombardo J, Perdrosa C, et al. Radial compression guided by mean artery pressure versus standard compression with a pneumatic device (RACOMAP). Catheter Cardiovasc Interv. 2009;73: Velsecchi O, Vassileva A, Musumeci G, et al. Failure of transradial approach during coronary interventions : anatomic considerations. Catheter Cardiovasc Interv. 2006;67: Arzamendi D, Romeo P, Gosselin G. Radial artery avulsion: a rare complication of percutaneous coronary intervention. Rev Esp Cardiol. 2011; 64: Pancholy S, Coppola J, Patel T, et al. Prevention of radial artery occlusion-patent hemostasis evaluation trial (PROPHET study): a randomized comparison of traditional versus patency documented hemostasis after transradial catheterization. Catheter Cardiovasc Interv. 2008; 72: Mamas MA, Fath-Ordoubadi F, Fraser DG. Atraumatic complex transradial intervention using large bore sheathless guide catheter. Catheter Cardiovasc Interv. 2008;72: Mamas M, D Souza S, Hendry C, et al. Use of the sheathless guide catheter during transradial percutaneous coronary intervention: a feasibility study. Catheter Cardiovasc Interv. 2010;75: Burzotta F, Trani C, Hamon M, et al. Transradial approach for coronary angiography and interventions in patients with coronary bypass grafts : tips and tricks. Catheter Cardiovasc Interv. 2008;72: Bertrand OF, De Larochellière R, Rodés-Cabau J, et al. A randomized study comparing same-day home discharge and abciximab bolus only to overnight hospitalization and abciximab bolus and infusion after transradial coronary stent implantation. Circulation. 2006;114: Sciahbasi A, Romagnoli E, Trani C, et al. Operator Radiation Exposure During Percutaneous Coronary Procedures Through the Left or Right Radial Approach: The TALENT Dosimetric Substudy. Circ Cardiovasc Interv. 2011;4(3): Cardiovascular Medicine 2011;14(11):
An Overview of Transradial Patient Set-up. Susan R. Cooney RN,BSN,CCRN Durham VAMC Cardiac Catheterization Lab Duke University School of Nursing
An Overview of Transradial Patient Set-up Susan R. Cooney RN,BSN,CCRN Durham VAMC Cardiac Catheterization Lab Duke University School of Nursing Advantages of the Transradial Approach from a Nursing Perspective!!
Radial Artery Access for Diagnostic and Interventional Procedures
for Diagnostic and Interventional Procedures Steven L. Almany, MD, FACC William W. O'Neill, MD, FACC 1999 by Accumed Systems, Inc. Ann Arbor, Michigan 1 Forward To be honest, I was extremely skeptical
Endovascular Repair of an Axillary Artery Aneurysm: A Novel Approach
Endovascular Repair of an Axillary Artery Aneurysm: A Novel Approach Bao- Thuy D. Hoang, MD 1, Jonathan- Hien Vu, MD 2, Jerry Matteo, MD 3 1 Department of Surgery, University of Florida College of Medicine,
Transulnar approach as an alternative access site for coronary invasive procedures after transradial approach failure
Transulnar approach as an alternative access site for coronary invasive procedures after transradial approach failure Pedro Beraldo de Andrade, MD, Marden André Tebet, MD, Ederlon Ferreira Nogueira, MD,
PRACTICE GUIDELINE TITLE: INTRAVENOUS LINE INSERTION: PERIPHERAL AND CENTRAL
PRACTICE GUIDELINE Effective Date: 9-17-04 Manual Reference: Deaconess Trauma Services TITLE: INTRAVENOUS LINE INSERTION: PERIPHERAL AND CENTRAL PURPOSE: To outline the indications and options for intravenous
The left internal mammary artery (LIMA) is the
Case Report 925 Direct Stenting of a Transradial Left Internal Mammary Artery Graft Wei-Chin Hung, MD; Bih-Fang Guo, MD, PhD; Chiung-Jen Wu, MD; Chien-Jen Chen, MD; Chih-Yuan Fang, MD Taking the transfemoral
Section Two: Arterial Pressure Monitoring
Section Two: Arterial Pressure Monitoring Indications An arterial line is indicated for blood pressure monitoring for the patient with any medical or surgical condition that compromises cardiac output,
Right Heart Catheterization from the Arm
Right Heart Catheterization from the Arm Mauricio G. Cohen, MD, FACC, FSCAI Director, Cardiac Catheterization Lab Associate Professor of Medicine 1 Disclosure Statement of Financial Interest Within the
Introduction to Cardiac Catheterisation The Nurse s Role
Introduction to Cardiac Catheterisation The Nurse s Role OVERVIEW Definition of the Catheter Lab Nurse Nursing Responsibilities Nurse Profile Nursing Skills OVERVIEW Definition of the Catheter Lab Nurse
Adult Forearm Fractures
Adult Forearm Fractures Your forearm is made up of two bones, the radius and ulna. In most cases of adult forearm fractures, both bones are broken. Fractures of the forearm can occur near the wrist at
Cardiac Catheterization
Page 1 Cardiac Catheterization What Other Terms Are Used To Describe Cardiac Catheterization? Heart Cath (catheter) Angiogram What Is Cardiac Catheterization? This procedure is nonsurgical and is performed
Complications of Femoral Catheterization. Daniel Kaufman, MD University Hospital of Brooklyn December 16, 2005
Complications of Femoral Catheterization Daniel Kaufman, MD University Hospital of Brooklyn December 16, 2005 Case Presentation xx yr old female presents with fever, chills, and painful swelling of R groin
Imaging of Thoracic Endovascular Stent-Grafts
Imaging of Thoracic Endovascular Stent-Grafts Tariq Hameed, M.D. Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, Indiana Disclosures: No relevant financial
The Cardiac Society of Australia and New Zealand
The Cardiac Society of Australia and New Zealand Guidelines on Support Facilities for Coronary Angiography and Percutaneous Coronary Intervention (PCI) including Guidelines on the Performance of Procedures
Ostial LAD: Single stent approach is the best. Antonio A. Pocoví, MD, FSCAI, MTSAC, Advisory Council Member, CACI
Ostial LAD: Single stent approach is the best Antonio A. Pocoví, MD, FSCAI, MTSAC, Advisory Council Member, CACI Chair, Interventional Cardiology Sanatorio San Lucas Instituto Alexander Fleming Buenos
How To Determine Pad
Process Representation #1 : The PAD algorithm as a sequential flow thru all sections An exploded version of the above scoped section flow is shown below. Notes: The flow presupposes existing services (
A Patient s Guide to Minimally Invasive Abdominal Aortic Aneurysm Repair
A Patient s Guide to Minimally Invasive Abdominal Aortic Aneurysm Repair Table of Contents The AFX Endovascular AAA System............................................ 1 What is an Abdominal Aortic Aneurysm
PERCUTANEOUS PD CATHETER IMPLANTATION SYSTEM
Place on Patient s Cranial Border of the Pubic Symphysis IMPLANTATION STENCIL Classic Exit Cuff Site PERCUTANEOUS PD CATHETER IMPLANTATION SYSTEM INSTRUCTIONS FOR USE VP 511 and VP-511M Implantation System
EFSUMB EUROPEAN FEDERATION OF SOCIETIES FOR ULTRASOUND IN MEDICINE AND BIOLOGY Building a European Ultrasound Community
MINIMUM TRAINING REQUIREMENTS FOR THE PRACTICE OF MEDICAL ULTRASOUND IN EUROPE Appendix 8: Vascular Ultrasound Level 1 Training and Practice Practical training should involve at least two half day ultrasound
Choice of guiding catheters and guidewires
Choice of guiding catheters and guidewires Dr. Ahmad Elsayed Yousef, MD Lecturer of Cardiology, Ain Shams University Werner Frossmann-1929 1 X-ray for angioraphy (1950-1970) Cine frame from the first selective
Is Stenting or Coronary Artery By-pass Grafting the Better Treatment for This Patient?
Is Stenting or Coronary Artery By-pass Grafting the Better Treatment for This Patient? --- NIRS-IVUS TVC Imaging Adds Additional Information for the Heart Team Dr. Luis Tami Memorial Regional Hospital
Clinical Research Intracoronary Stenting with Crushing in Coronary Artery Bifurcation Lesions: Initial Results and Medium-Term Follow Up
Hellenic J Cardiol 45: 379-383, 2004 Clinical Research Intracoronary Stenting with Crushing in Coronary Artery Bifurcation Lesions: Initial Results and Medium-Term Follow Up PETROS S. DARDAS, DIMITRIS
X-Plain Subclavian Inserted Central Catheter (SICC Line) Reference Summary
X-Plain Subclavian Inserted Central Catheter (SICC Line) Reference Summary Introduction A Subclavian Inserted Central Catheter, or subclavian line, is a long thin hollow tube inserted in a vein under the
How to measure blood pressure using digital monitors
How to measure blood pressure using digital monitors What is high blood pressure? Blood pressure is the pressure exerted by circulating blood upon the walls of blood vessels. Systolic pressure is the blood
Right Heart Catheterization
Right Heart Catheterization Ian C Gilchrist, MD, FSCAI Professor of Medicine Heart & Vascular Institute Penn State/Hershey Medical Center Hershey, PA DUKE 2010 Presenter Disclosure Information Ian C. Gilchrist,
REPORTING STENT PLACEMENT FOR NONOCCLUSIVE VASCULAR DISEASE IN LOWER EXTREMITIES
REPORTING STENT PLACEMENT FOR NONOCCLUSIVE VASCULAR DISEASE IN LOWER EXTREMITIES Effective January 1, 2015, there was a change in CPT that affects reporting specific endovascular services provided in the
Paediatric Intensive Care Unit Nursing Procedure: Care of Arterial Lines.
Paediatric Intensive Care Unit Nursing Procedure: Care of Arterial Lines. Definition: Arterial Line Placement of an indwelling arterial catheter for the purpose of continuous monitoring of intra arterial
Chapter 6. Hemorrhage Control UNDER FIRE KEEP YOUR HEAD DOWN
Hemorrhage Control Chapter 6 Hemorrhage Control The hemorrhage that take[s] place when a main artery is divided is usually so rapid and so copious that the wounded man dies before help can reach him. Colonel
Vascular Access. Chapter 3
Vascular Access Chapter 3 Vascular Access Introduction Obtaining vascular access in infants and children can be difficult even under optimal conditions. Attempting emergent access in a hypotensive, struggling
Experience of Direct Coronary Stenting at National Institute of Cardiovascular Diseases
Experience of Direct Coronary Stenting at National Institute of Cardiovascular Diseases T. Masood,T. Sagheer,D. Jan,N. Qamar,A.M.A. Faruqui ( National Institute of Cardiovascular Diseases (NICVD), Karachi.
Antiplatelet and anticoagulation treatment of patients undergoing carotid and peripheral artery angioplasty
Round Table: Antithrombotic therapy beyond ACS Antiplatelet and anticoagulation treatment of patients undergoing carotid and peripheral artery angioplasty M. Matsagkas, MD, PhD, EBSQ-Vasc Associate Professor
A PROCEDURAL GUIDE TO MIDLINE CATHETER INSERTION
A PROCEDURAL GUIDE TO MIDLINE CATHETER INSERTION See Also CPG midline catheters for indications, contraindications and post insertion management What is a midline A midline catheter is an 8-12 cm catheter
Samir B. Pancholy, MD, FACC, FSCAI 570-840-9852
Samir B. Pancholy, MD, FACC, FSCAI 570-840-9852 Medical School: B.J. Medical College, Ahmedabad, India 6-1981 to 5-1987. Residency: State University of New York at Stony Brook, Stony Brook, NY, Internal
THORACIC OUTLET SYNDROME
THORACIC OUTLET SYNDROME The Problem The term thoracic outlet syndrome is used to describe a condition of compression of the nerves and/or blood vessels in the region around the neck and collarbone, called
Bier Block (Intravenous Regional Anesthesia)
Bier Block (Intravenous Regional Anesthesia) History August Bier introduced this block in 1908. Early methods included the use of two separate tourniquets and procaine was the local anesthetic of choice.
Subclavian Steal Syndrome By Marta Thorup
Subclavian Steal Syndrome By Marta Thorup Definition Subclavian steal syndrome (SSS), is a constellation of signs and symptoms that arise from retrograde flow of blood in the vertebral artery, due to proximal
Liau DW : Injuries and Liability Related to Peripheral Catheters: A Closed Claims Analysis. ASA Newsletter 70(6): 11-13 & 16, 2006.
Citation Liau DW : Injuries and Liability Related to Peripheral Catheters: A Closed Claims Analysis. ASA Newsletter 70(6): 11-13 & 16, 2006. Full Text An anesthesiologist inserted a 14-gauge peripheral
Ankle Block. Indications The ankle block is suitable for the following: Orthopedic and podiatry surgical procedures of the distal foot.
Ankle Block The ankle block is a common peripheral nerve block. It is useful for procedures of the foot and toes, as long as a tourniquet is not required above the ankle. It is a safe and effective technique.
Groin Dressing post Cardiac Catheterization: Traditional pressure Versus Transparent Film. BSN, MSN, Clinical nursing, Critical Care Nursing
Groin Dressing post Cardiac Catheterization: Traditional pressure Versus Transparent Film BSN, MSN, Clinical nursing, Critical Care Nursing Introduction Transfemoral percutaneous coronary procedures have
Policies and Procedures. Related to. IABP Therapy
Policies and Procedures Related to IABP Therapy Courtesy of Datascope Corp. Clinical Support Services The following policies and procedures are intended to serve as guidelines for developing hospital policy.
Percutaneous Transluminal Angioplasty (PTA) and Stenting For PVS Patients
Percutaneous Transluminal Angioplasty (PTA) and Stenting For PVS Patients There are two types of blood vessels in the body arteries and veins. Arteries carry blood rich in oxygen from the heart to all
Coronary Stents. What is a Coronary Artery stent?
What is a Coronary Artery stent? Coronary Stents A coronary stent is stainless tube with slots. It is mounted on a balloon catheter in a "crimped" or collapsed state. When the balloon of is inflated, the
Policies & Procedures. I.D. Number: 1087
Policies & Procedures Title: CARDIAC CATHETERIZATION CARE OF THE CLIENT I.D. Number: 1087 Authorization: [X] SHR Nursing Practice Committee Source: Heart Health Cross Index: Date Revised: November 2013
Angioplasty and Stent Education Guide
Angioplasty and Stent Education Guide Table of Contents Treating coronary artery disease...2 What is coronary artery disease...3 Coronary artery disease treatment options...4 What are coronary artery
PERIPHERALLY INSERTED CENTRAL CATHETERS (PICC) Fong So Kwan APN, Haematology unit Medical Department, QMH
PERIPHERALLY INSERTED CENTRAL CATHETERS (PICC) Fong So Kwan APN, Haematology unit Medical Department, QMH 1 What is a PICC catheter? Primary vascular access device since their introduction in the mid-1970s,
Vascular Technology (VT) Content Outline Anatomy & physiology 20% Cerebrovascular Cerebrovascular normal anatomy Evaluate the cerebrovascular vessels
Vascular Technology (VT) Content Outline Anatomy & physiology 20% normal anatomy Evaluate the cerebrovascular vessels hemodynamics Evaluate the cerebrovascular vessels for normal perfusion normal anatomy
Difficult Vascular Access Alternative Approaches & Troubleshooting Tips
Difficult Vascular Access Alternative Approaches & Troubleshooting Tips Michelle Lin, MD Associate Professor of Clinical Emergency Medicine UC San Francisco - San Francisco General Hospital [email protected]
Cardiac Catheterization Lab Procedures
UW MEDICINE PATIENT EDUCATION Cardiac Catheterization Lab Procedures This handout describes how cardiac catheterization works. It also explains how to prepare for your procedure and the self-care needed
The Bioresorbable Vascular Stent Dr Albert Ko
The Bioresorbable Vascular Stent Dr Albert Ko Dr Albert Ko MB BS, FRACP, FCSANZ Interventional/General Cardiologist Ascot Cardiology Symposium 2013 Treatment Goals for Coronary Artery Disease Relieve of
Heart Attack: What You Need to Know
A WorkLife4You Guide Heart Attack: What You Need to Know What is a Heart Attack? The heart works 24 hours a day, pumping oxygen and nutrient-rich blood to the body. Blood is supplied to the heart through
A PATIENT S GUIDE TO CARDIAC CATHETERIZATION
A PATIENT S GUIDE TO CARDIAC CATHETERIZATION The science of medicine. The compassion to heal. This teaching booklet is designed to introduce you to cardiac catheterization. In the following pages, we will
Tunneled Hemodialysis Catheters: Placement and complications
Tunneled Hemodialysis Catheters: Placement and complications Arif Asif, M.D. Director, Interventional Nephrology Associate Professor of Medicine University of Miami, FL Tunneled Hemodialysis Catheters:
Inferior Vena Cava filter and removal
Inferior Vena Cava filter and removal What is Inferior Vena Cava Filter Placement and Removal? An inferior vena cava filter placement procedure involves an interventional radiologist (a specialist doctor)
Chapter 33. Nerve Physiology
Chapter 33 NERVE AND VASCULAR INJURIES OF THE HAND KEY FIGURES: Digital nerve location on finger Epineurial repair Nerves and blood vessels of the hand and fingers usually are quite delicate, and some
Duration of Dual Antiplatelet Therapy After Coronary Stenting
Duration of Dual Antiplatelet Therapy After Coronary Stenting C. DEAN KATSAMAKIS, DO, FACC, FSCAI INTERVENTIONAL CARDIOLOGIST ADVOCATE LUTHERAN GENERAL HOSPITAL INTRODUCTION Coronary artery stents are
CORONARY ARTERY BYPASS GRAFTS, STENTS, AND EXTRACORONARY CARDIAC DZ. Charles White MD
CORONARY ARTERY BYPASS GRAFTS, STENTS, AND EXTRACORONARY CARDIAC DZ Charles White MD Director of Thoracic Imaging Department of Radiology University of Maryland CORONARY ARTERY BYPASS GRAFTS First performed
An Informative Guide for Heart Catheterization Patients & Families
An Informative Guide for Heart Catheterization Patients & Families What is a Cardiac Cath? Cardiac catheterization is a procedure used to diagnose and treat patients who have various forms of heart disease.
The treatment of peripheral vascular disease has
Covered s in Peripheral Vascular Aneurysms and Emergencies Reviewing current covered stent selection and use through case study and discussion. By Alberto Posabella, MD; Raffaele Rosso, MD, FACS, FRCS;
Current Status: Draft PolicyStat ID: 1547809 EZIO
Current Status: Draft PolicyStat ID: 1547809 Originated: Reviewed: Last Revised Or Downloaded: Expiration: Document Area: N/A N/A N/A N/A Nursing POLICY STATEMENT: EZIO In the event that peripheral venous
Cardiac Catheterization Curriculum for Fellows in Cardiology Dartmouth-Hitchcock Medical Center Level 1 and Level 2 Training 2008-2009
Cardiac Catheterization Curriculum for Fellows in Cardiology Dartmouth-Hitchcock Medical Center Level 1 and Level 2 Training 2008-2009 I. Overview of Training in Cardiac Catheterization Cardiac catheterization
Talent Thoracic Stent Graft with THE Xcelerant Delivery System. Expanding the Indications for TEVAR
Talent Thoracic with THE Xcelerant Delivery System Expanding the Indications for TEVAR Talent Thoracic Precise placement 1 Broad patient applicability 1 Excellent clinical outcomes 1, a + Xcelerant Delivery
Coronary Arteries: Number of Vessels/Number of Stents
Coronary Arteries: Number of Vessels/Number of Stents Issue Should code table 027 be revised to capture the number of coronary vessels treated and/or the number of coronary stents inserted? New Technology
Common Regional Nerve Blocks Quick Guide developed by UWHC Acute Pain Service Jan 2011
Common Regional Nerve Blocks Quick Guide developed by UWHC Acute Pain Service Jan 2011 A single shot nerve block is the injection of local anesthetic to block a specific nerve distribution. It can be placed
NIH Clinical Center Patient Education Materials Giving a subcutaneous injection
NIH Clinical Center Patient Education Materials What is a subcutaenous injection? A subcutaneous injection is given in the fatty layer of tissue just under the skin. A subcutaneous injection into the fatty
Understanding Coronary Artery Disease, Cardiac Catheterization, and Treatment Options. A Guide for Patients
Understanding Coronary Artery Disease, Cardiac Catheterization, and Treatment Options A Guide for Patients Coronary Artery Disease If you or a member of your family has been diagnosed with coronary artery
BD Saf-T-Intima. Hidden talents of BD Saf-T-Intima. BD SAF-T-Intima and SUBCUTANEOUS THERAPY REHYDRATION PALLIATIVE CARE. POST OPERATIVe PAIN RELIEF
Hidden talents of BD Saf-T-Intima BD Saf-T-Intima SUBCUTANEOUS INFUSION REHYDRATION PALLIATIVE CARE BD SAF-T-Intima and SUBCUTANEOUS THERAPY PAEDIATRIC CARE POST OPERATIVe PAIN RELIEF BD Saf-T-Intima First
Coronary angiogram : An author view Patwary MSR
The ORION Medical Journal 2008 Sep;31:599-601 Coronary angiogram : An author view Patwary MSR Abstract It is relatively safe, though minimally invasive, test. Coronary angiogram is an x-ray of the coronary
Catheter Reduction Program: Creating the Ideal Vascular Access Culture. Presented by: Diane Peck, RN, CNN
Catheter Reduction Program: Creating the Ideal Vascular Access Culture Presented by: Diane Peck, RN, CNN Fistula First Initiative The superiority of an AVF over an AVG is an accepted fact. For this reason
STONY BROOK UNIVERSITY HOSPITAL VASCULAR CENTER CREDENTIALING POLICY
STONY BROOK UNIVERSITY HOSPITAL VASCULAR CENTER CREDENTIALING POLICY Per Medical Board decision March 18, 2008: These credentialing standards do NOT apply to peripheral angiography performed in the context
ARTERIAL PUNCTURE PROCEDURE
1 of 6 Policy #: 407 (PLH-407-05) Effective Date: 9/30/2004 Reviewed Date: 7/1/2015 Subject: ARTERIAL PUNCTURE PROCEDURE Approved by: Laboratory Director, Jerry Barker (electronic signature) Approved by:
CMS Limitations Guide - Radiology Services
CMS Limitations Guide - Radiology Services Starting October 1, 2015, CMS will update their existing medical necessity limitations on tests and procedures to correspond to ICD-10 codes. This limitations
Epidural Continuous Infusion. Patient information Leaflet
Epidural Continuous Infusion Patient information Leaflet April 2015 Introduction You may already know that epidural s are often used to treat pain during childbirth. This same technique can also used as
Percutaneous closure of paravalvular leaks EULOGIO GARCIA MD MADRID ~ SPAIN
Percutaneous closure of paravalvular leaks EULOGIO GARCIA MD MADRID ~ SPAIN BACKGROUND The incidente of paravalvular leaks is variable ( from 2% up to 17% ). More frequent in mechanical valves. Surgical
Medications or therapeutic solutions may be injected directly into the bloodstream
Intravenous Therapy Medications or therapeutic solutions may be injected directly into the bloodstream for immediate circulation and use by the body. State practice acts designate which health care professionals
Policies & Procedures. I.D. Number: 1073
Policies & Procedures Title:: CENTRAL VENOUS CATHETERS INSERTION ASSISTING I.D. Number: 1073 Authorization [] Pharmacy Nursing Committee [] MAC Motion #: [x] SHR Nursing Practice Committee Source: Nursing
RELAY Plus Thoracic Stent-Graft System with Transport Delivery System
RELAY Plus Thoracic Stent-Graft System with Transport Delivery System TABLE OF CONTENTS Section Page DEVICE DESCRIPTION 8 RADIOPAQUE MARKER BANDS 8 RELAY PLUS TRANSPORT DELIVERY SYSTEM 8 INDICATIONS FOR
Patient Information Booklet. Endovascular Stent Grafts: A Treatment for Abdominal Aortic Aneurysms
Patient Information Booklet Endovascular Stent Grafts: A Treatment for Abdominal Aortic Aneurysms TABLE OF CONTENTS Introduction 1 Glossary 2 Abdominal Aorta 4 Abdominal Aortic Aneurysm 5 Causes 6 Symptoms
UW MEDICINE PATIENT EDUCATION. Aortic Stenosis. What is heart valve disease? What is aortic stenosis?
UW MEDICINE PATIENT EDUCATION Aortic Stenosis Causes, symptoms, diagnosis, and treatment This handout describes aortic stenosis, a narrowing of the aortic valve in your heart. It also explains how this
Minimally Invasive Spine Surgery
Chapter 1 Minimally Invasive Spine Surgery 1 H.M. Mayer Primum non nocere First do no harm In the long history of surgery it always has been a basic principle to restrict the iatrogenic trauma done to
Welcome to the July 2012 edition of Case Studies from the files of the Institute for Nerve Medicine in Santa Monica, California.
Welcome to the July 2012 edition of Case Studies from the files of the Institute for Nerve Medicine in Santa Monica, California. In this issue, we focus on a 23-year-old female patient referred by her
Femoral artery bypass graft (Including femoral crossover graft)
Femoral artery bypass graft (Including femoral crossover graft) Why do I need the operation? You have a blockage or narrowing of the arteries supplying blood to your leg. This reduces the blood flow to
FEMORAL ARTERY SHEATH MANAGEMENT
Centre for Education & Practice Development Learning Module FEMORAL ARTERY SHEATH MANAGEMENT For Registered Nurses Division 1 February 2008 Acknowledgment This document has been compiled utilising the
Therapeutic Approach in Patients with Diabetes and Coronary Artery Disease
Home SVCC Area: English - Español - Português Therapeutic Approach in Patients with Diabetes and Coronary Artery Disease Martial G. Bourassa, MD Research Center, Montreal Heart Institute, Montreal, Quebec,
Malfunctioning PD Catheters
Malfunctioning PD Catheters Introduction Migration reported to occur in between 5% to 35% of the implanted catheters. majority migrates to the right upper quadrant suggests that the problem bears a relationship
Self- Lymphatic Massage for Arm, Breast or Trunk Lymphedema
Self- Lymphatic Massage for Arm, Breast or Trunk Lymphedema Patient Education Improving health through education The lymphatic system is part of our circulatory system. It helps balance the fluids of our
Dressing and bandage
Dressing and bandage Mihajlo Lojpur, M.D., Ph.D. INTRODUCTION The terms dressing and bandage are often used synonymously. In fact, the term dressing refers more correctly to the primary layer in contact
Wrist Fracture. Please stick addressograph here
ORTHOPAEDIC UNIT: 01-293 8687 /01-293 6602 UPMC BEACON CENTRE FOR ORTHOPAEDICS: 01-2937575 PHYSIOTHERAPY DEPARTMENT: 01-2936692 GUIDELINES FOR PATIENTS FOLLOWING WRIST FRACTURE Please stick addressograph
Cardiac Catheterisation. Cardiology
Cardiac Catheterisation Cardiology Name: Cardiac catheterisation Version: 1 Page 1 of 7 Contents Page Number(s) 1. Introduction 3 2. Management pre operative 3 3. Management post operative 5 4. Discharge
Chapter 3. Ulnar nerve infiltration
Chapter 3 LOCAL ANESTHESIA KEY FIGURES: Digital block/anatomy Sensation to hand Median nerve infiltration Ulnar nerve infiltration Facial block: skeleton Full surgical evaluation of a wound and suture
PROCEDURE FOR SUBCUTANEOUS INSERTION, REMOVAL, MEDICATION ADMINISTRATION AND FLUID ADMINISTRATION FOR COMMUNITY PALLIATIVE CARE PATIENTS
PROCEDURE FOR SUBCUTANEOUS INSERTION, REMOVAL, MEDICATION ADMINISTRATION AND FLUID ADMINISTRATION FOR COMMUNITY PALLIATIVE CARE PATIENTS Approved: February 2010 Date for review: February 2010 1 PROCEDURE
Renovascular Hypertension
Renovascular Hypertension Philip Stockwell, MD Assistant Professor of Medicine (Clinical) Warren Alpert School of Medicine Cardiology for the Primary Care Provider September 28, 201 Renovascular Hypertension
Components of CVC Care Bundle. selection
Components of CVC Care Bundle Catheter site selection Site of insertion influences the subsequent risk for CR-BSI and phlebitis The influence of site is related in part to the risk for thrombophlebitis
Epidurals for pain relief after surgery
Epidurals for pain relief after surgery This information leaflet is for anyone who may benefit from an epidural for pain relief after surgery. We hope it will help you to ask questions and direct you to
TAXUS Express 2. Paclitaxel-Eluting Coronary Stent System. Patient Information Guide
TAXUS Express 2 Paclitaxel-Eluting Coronary Stent System Patient Information Guide 1 Table of Contents Coronary Artery Disease...2 Who Is at Risk?...3 Diagnosis of Coronary Artery Disease...3 Treatment
Upper Extremity Arterial Duplex Evaluation
VASCULAR TECHNOLOGY PROFESSIONAL PERFORMANCE GUIDELINES Upper Extremity Arterial Duplex Evaluation This Guideline was prepared by the Professional Guidelines Subcommittee of the Society for Vascular Ultrasound
Arterial pressure monitoring Direct arterial pressure monitoring permits continuous measurement of systolic, diastolic, and mean pressures and allows
Arterial pressure monitoring Direct arterial pressure monitoring permits continuous measurement of systolic, diastolic, and mean pressures and allows arterial blood sampling. Because direct measurement