DC4812VRF Installation Guide
|
|
|
- Polly Mathews
- 10 years ago
- Views:
Transcription
1 DC4812VRF Installation Guide Version 1.4 Copyright 2013 HotSpot Energy 1
2 Notice To Owner/Installer This unit is designed for installation by an experienced person. It is legal for a homeowner to install it, however we highly recommend using a licensed HVAC technician for installation. There is high-voltage DC power used inside and outside of the unit. There are capacitors inside the unit that may contain dangerous levels of power even after the unit has been disconnected from its power source. The power must be disconnected and all of the capacitors must be discharged before servicing the system. Legal Information About Self-Installing R-410A Air Conditioners Can a homeowner install this system? Yes, a homeowner with a vacuum pump, proper training, and equipment can install this unit. Unless you are experienced with installing air conditioners we recommend you hire a professional installer. The person who installs the system must do all work in compliance with local building and electrical codes. Are there any restrictions on the purchase of R410A refrigerants? R-410A is not an ozone-depleting substance. At this time the purchase of R-410A refrigerant is not restricted in the US. There is no technician certification requirement for those that purchase HFC refrigerants, such as R-410a or R-134a. If you are not licensed, some local HVAC supply companies may refuse to sell you R410A based on a misunderstanding of the law, or because they wish to discourage homeowners from working on their own systems. Are there any restrictions on the use of R410A refrigerants? Yes, it is illegal to knowingly vent or release these refrigerants. The venting prohibition applies to R410A, and all other HFC refrigerants, just as it does for ozone-depleting refrigerants like R-22. Is EPA technician certification required to service R410A systems? No, at this time EPA technician certification is not required in order to service R-410a systems. Source: HotSpot recommends that only a licensed air conditioning contractor be allowed to install or service this unit. Copyright 2013 HotSpot Energy 2
3 WARNING! This unit uses high voltage DC power. There are multiple capacitors within the unit that may contain dangerous power, even after the power supply has been disconnected. Capacitors MUST BE DISCHARGED before servicing any electrical components of this unit! Refer any installation or service to a qualified professional. HVAC professionals can contact HotSpot for downloadable service manual. Copyright 2013 HotSpot Energy 3
4 DC4812VRF DC Air Conditioner Installation Guide Table of Contents Cover Page 1 Notice To Owner/Installer 2 Capacitor Warning 3 Table of Contents 4 Safety Precautions 5 Selecting Installation Location 6 Indoor Unit Installation 7 Connecting Power Cables 10 Outdoor Unit Installation 13 Recharging Empty Unit 17 Outdoor Electrical 19 Battery Plant 22 Solar Installation 23 Charge Controller 25 Cabling, Mounting, Grounding 27 Generator Tie-In 28 Copyright 2013 HotSpot Energy 4
5 SAFETY PRECAUTIONS Please read this installation manual completely before installing the product. If the power cable is damaged, replacement work shall be performed by authorized personnel only. Installation must be performed in accordance with the NEC and CEC by authorized personnel only. All the pictures in the instructions are for explanation purposes only. The actual shape may vary. Contact an authorized service technician for repair, maintenance or installation of this unit. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. WARNING Strictly adhere to the instructions in this manual. If the installation manual is not followed, it may cause water leakage, electrical shock, fire, death. Use the attached accessories parts and specified parts for the installation, otherwise, it will cause the unit to fail, water leakage, electrical shock, and possibly fire. Install at a suitable and firm location which is able to withstand the units weight. If the unit is mounted on an approved bracket, unit may drop and cause injury. For electrical work, follow all local and national wiring codes and these installation instructions. Use the proper size and type of cable and connect it tightly, clamp the cable so that no external force will be present on the terminal. If the connection or fitting is not tight, it may heat-up or could cause a fire at the connection. Wire routing must be properly arranged so that control board cover is properly fitted. If control board cover is not fitted perfectly, it may cause the connection to heat up and could cause a fire or electrical shock. When installing the line set, take care not to let moisture or foreign substances other than the specified refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure in the refrigeration cycle, possible explosion and injury. This equipment must be grounded and installed according to the NEC. It may cause electrical shock or damage to the system if not grounded properly. Do not install the unit in a location where leakage of flammable gas may occur. If flammable gas leaks and accumulates near the unit, it may cause a fire or explosion. This unit produces condensate. Install the drain piping as mentioned in the installation instructions. If drainage is not correct, water may enter the room and cause damage. This unit uses high voltage DC power. There are multiple capacitors within the unit that may contain dangerous power, even after the power supply has been disconnected. Refer any service to a qualified professional. See the DC4812VRF SERVICE MANUAL for service information. Capacitors MUST BE DISCHARGED before servicing any electrical components of this system! Batteries: Make sure to follow the NEC and instructions provided by the battery manufacturer when wiring, connecting, and grounding the battery plant. Charge Controllers: Make sure to follow the NEC and instructions provided by the manufacturer. Solar Array: Follow the NEC and manufacturers instructions for mounting, connecting, and grounding solar power components. Copyright 2013 HotSpot Energy 5
6 SELECT THE BEST LOCATION Indoor unit There should not be any heat source or steam near the unit. There should not be any obstacles blocking the air circulation. Choose a location where air flow is good. Choose a location where condensate drainage can be easily done and where noise prevention is taken into consideration. Do not install the unit near the en trance or exit of the room. Ensure the clearances indicated by arrows, from the wall, ceiling, fence or other obstacles. See figure 1. There should not be any direct sunlight on the indoor unit. If unavoidable, sunlight prevention should be taken into consideration. Outdoor unit If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the condenser is not obstructed. There should not be any animals or plants near the unit which could be affected by hot air discharged. Ensure the clearances indicated by arrows, from the wall, ceiling, fence or other obstacles. See figure 2 1 Installation Plate 1 2 Clip Anchor 5-8 Depending on the model 3 Self-tapping Screw AST 3.9 x Depending on the model 4 Seal 1 Do not place any obstacles on the unit that may interfere with the discharged air flow. Placement of the outdoor unit Anchor the outdoor unit with a bolt and nut 10 or 8 tightly and horizontally on a concrete or rigid mount. NOTE: Install the outdoor unit according to the dimension as indicated below: Outdoor Unit Dimensions (760 x 590 x 285) mm 5 Drain Joint(For cooling & heating models 1 only) 6 Line Set Liquid side 6.35 mm 1/4 Parts you must purchase. Gas Side 9.52 mm 1/2 Parts you must purchase. 7 Control Cable Refer to page 11 for control cable details Parts you must purchase. 8 Remote controller 1 9 Self-tapping Screw B ST2.9x10 2 Optional Parts 1 0 Remote controller holder 1 Optional Parts Figure 2 Copyright 2013 HotSpot Energy 6
7 FITTING THE INSTALLATION PLATE NOTE: Fitting The Installation Plate Ensure that the mounting wall is strong and solid enough to prevent vibration. 1. Fit the installation plate horizontally on structural parts of the wall with spaces around the installation plate. See figure 3 2. If the wall is made of brick, concrete or the like, drill eight (8) 5mm diameter holes in the wall and insert anchor clips for appropriate mounting screws. 3. Fit the installation plate on the wall with eight (8) type A screws. Fit the Installation Plate and drill holes in the wall according to the wall structure and corresponding mounting points on the installation plate. The installation plate is provided with the machine. (Dimensions are in mm unless otherwise stated) For correct orientation of Installation plate see figure 4. DRILL A HOLE IN THE WALL 1. Determine left and right side hole positions according to the installation plate. The hole center is obtained by measuring the distance as shown in the diagram figure 2. Drill the piping plate hole with 65mm hole saw drill bit. 3. Drill the piping hole at either the right or the left side. The hole should be slightly slanted to the outdoor side for condensate water drainage. See figure 5 4 Always use conduit when drilling through metal grid, metal plate or the like. Figure 3 Figure 4 Figure 5 Copyright 2013 HotSpot Energy 7
8 CONNECTIVE PIPE AND DRAINAGE INSTALLATION DRAINAGE 1. Run the drain hose sloping downward. Do not install the drain hose as illustrated in figure 6 2. When connecting the extension drain hose, seal the connecting part of extension drain hose with water proof tape, do not let the drain hose slack. Connect the indoor unit first, then the outdoor unit. Figure 6 CONNECTIVE PIPE INSTALLATION 1. For the left- hand and right-hand piping, remove the pipe cover from the side panel. 2. For the rear-right-hand and rear-left hand piping, install the piping as shown in figure Bundle the tubing, connecting cable, and drain hose securely with tape, evenly, as shown in figure 8, on the right. Because the condensed water from rear of the indoor unit is gathered in a reservoir and is piped out of room, do not put anything else in the reservoir. CAUTION Connect the indoor unit first, then the outdoor unit. Do not allow the piping to hang out from the back of the indoor unit. Figure 7 Be careful not to let the drain hose slack. Use insulation such as Armaflex to insulate the line set. Be sure that the drain hose is located at the lowest side of the bundle. See figure 8. If drain hose is located at the upper side it can cause drain tray to overflow inside the unit. Never intercross or wind the power wire with any other wiring. Run the drain hose sloped downward to drain out the condensed water smoothly. Figure 8 Copyright 2013 HotSpot Energy 8
9 INDOOR UNIT INSTALLATION 1. Pass the piping through the hole in the wall. See figure Hook the indoor unit onto the upper portion of installation plate (Engage the indoor unit with the upper edge of the installation plate). Ensure the hooks are properly seated on the installation plate by moving it in left and right motions. 3. Piping can be made by easy by supporting the indoor unit with a cushioning material between the indoor unit and the wall. Remove it after finishing the piping. See figure Press the lower left and right side of the unit against the installation plate until hooks engages with their slots. Figure 9 Figure 10 Copyright 2013 HotSpot Energy 9
10 CONNECTING POWER CABLES ELECTRICAL WORK MAKE SURE TO USE SHIELDED WIRE FOR WIRING THE COMMUNICATIONS CABLE BETWEEN INDOOR AND OUTDOOR UNIT The following is a general guide. FOLLOW NEC FOR ALL WIRING. 1. If there is a safety problem with installing the 48 VDC AC unit, the technician should refuse to install the air conditioner and explain to the customer that the problem must be resolved before continuing the installation. 2. Power voltage should be in the range of 46v to 58v DC. 3. Ensure the air conditioner, panels, charging system, and batteries are properly grounded. 4. All components shall be installed in accordance with National Electrical Code. 5. Do not install the air conditioner in a wet room such as a bath room or laundry room. 6. A disconnection capability must exist on or between the charge controller and battery bank. A DC rated disconnect should be used between the battery bank and the AC unit in accordance with the NEC. 7. Keep the unit at least 36 away from combustible materials. 8. Refer to the Electrical Connection Diagram located on the panel of the indoor & outdoor unit to connect the wires. All wiring must comply with local and national electrical codes and be installed by a qualified electrician. MINIMUM WIRE SIZE (AWG: American Wire Gauge) You can use a voltage drop calculator to determine the minimum AWG based on the voltage, amps, and distance. There is a wire size/voltage drop calculator at Allowable Voltage Drop (%): The percentage of voltage drop acceptable. This is typically allowed to be 5% or lower in ELV systems. HotSpot recommends <3% voltage drop. Rated Current : Per AS as "The maximum 30 minute average of apparent power or DC power consumption (measured in volt-amperes for AC and watts for DC)". We calculate based on the maximum current that the cable is to carry. ELV System Voltage: The nominal system voltage is 48 volts for the HotSpot DC4812VRF DC air conditioner. The nominal system voltage for the PV/charge controller configuration will depend on the string sizing. HotSpot assumes PV string voltage of 100v for its AWG recommendations. FOLLOW THE NEC AND USE THE GUIDE ON PAGE 11 FOR PROPER AWG SIZING. Copyright 2013 HotSpot Energy 10
11 AWG Wire Gauge Sizing Guide For DC4812VRF Air Conditioner Connect 48v DC power from batteries to terminals as shown below. E refers to Earth Ground. DC4812VRF Air Conditioner Minimum Wire Gauge Sizing Chart for Connecting Outdoor Power Distance 10 ft. 20 ft. 30 ft. 40 ft. 50 ft. 75 ft. 100 ft. HotSpot Recommended AWG AWG AWG AWG AWG AWG AWG AWG Solar PV to Charge Controller Charge Controller to Batteries NA NA NA NA NA Batteries to ODU Connect outdoor unit (ODU) (below, left) to indoor unit (IDU) (below, right) as shown below: Copyright 2013 HotSpot Energy 11
12 Connecting To The Indoor Unit NOTE: Before performing any electrical work, turn off the main power to the system AND MAKE SURE ALL CAPACITORS ARE DISCHARGED. 1. The (5) five inside connecting cables can be connected without removing the front grille. 2. The 5 connecting power cable s must be sized correctly, see page Lift the indoor unit panel up, remove the electrical box cover by loosening the screw. 4. Ensure the color code of the indoor unit wire terminals match the outdoor unit terminal numbers and the wiring diagram. 5. Wrap any cables not connected with terminals with insulation tape so that they will not touch any electrical components. Secure the cable onto the control board with the cable clamp. Figure 11 Figure 12 OUTDOOR INSTALLATION PRECAUTION Install the outdoor unit on a rigid base to prevent excess noise and vibration. Determine the air inlet and outlet direction, be sure that the flow of air is not blocked. In the case that the installation site is exposed to strong winds such as the ocean front, make sure the fan can operate properly by putting the unit lengthwise along the wall or using a dust or wind shield. See figure 13. If using an installation bracket, the installation bracket should be installed according to the installation bracket diagram. The installation wall should be solid brick, concrete or similar level of construction, or actions to reinforce the supporting bracket should be taken. The connection between the bracket and wall, and the bracket and the air conditioner should be firm, stable and reliable. Be sure there are no obstacles which can block the flow of air. Figure 13 Copyright 2013 HotSpot Energy 12
13 DRAIN JOINT INSTALLATION NOTE: The drain joint may differ slightly from the diagram. For the drain joint with the seal, Fig. A, first fit the seal onto the drain joint, then, insert the drain joint into the base pan hole of outdoor unit. Rotate it 90 degrees to secure it in place. To install drain joint as shown in Fig. B, insert the drain joint into the base pan hole of outdoor unit until it remains fixed with a clicking sound. Connect the drain joint with an extension drain hose (Locally purchased), in case of water draining off the outdoor unit during the heating or cooling mode. REFRIGERANT PIPE CONNECTION Flaring 1. Cut a pipe with a pipe cutter. 2.Remove flare nuts attached to the indoor and out door units. Slide them over the end of the pipes after removing burs from the pipes, and flare the pipe. 3.Firmly hold copper pipe in a die in the dimensions shown in the table below. Outer diam. 6.35mm or 1/4 12.7mm or 1/2 A(mm) Max. Min Tightening connection Align pipes to be connected. Sufficiently tighten the flare nut with fingers, and then tighten it with a torque wrench as shown. Be careful - excessive torque can break or damage the nut. Outer diam. Tightening torque(n.cm) Additional tightening torque(n.cm) 6.35mm or 1/4 1500(153kgf.cm) 1600(163kgf.cm) 12.7mm or 1/2 3500(357kgf.cm 3600(367kgf.cm) Use proper torque to ensure a good seal. Do not over-tighten. Copyright 2013 HotSpot Energy 13
14 CONNECT THE CABLE TO THE OUTDOOR UNIT 1. Remove the electrical control board cover from the outdoor unit by loosening the screw. See figure Connect the connective cables to the terminals as identified with their respective matched numbers on the terminal block of indoor and outdoor units. See figure Secure the cable onto the control board with the plastic cable clamp. 4. To prevent the ingress of water, form a loop of the connective cable as illustrated in the installation diagram of indoor and outdoor units. 5. Insulate unused cords (conductors) with PVC-tape so they do not touch any electrical or metal parts. Figure 17 AIR PURGING AND TEST OPERATION Figure 18 Outdoor unit connects to 48v DC Power only. Use cable AWG sized per distance calculations (see page 11.) Note: Line set pipe length will affect the capacity and energy efficiency of the unit. The nominal efficiency is tested basing on the pipe length of 7.5 meters. Air purging Air and moisture in the refrigerant system have undesirable effects and can damage the system. Therefore, the indoor unit and tubing between the indoor and outdoor unit must be leak tested and evacuated to remove any non-condensables and moisture from the system. Check that each tube (both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the test run has been completed. Make sure to properly evacuate the system using a vacuum pump. Pipe length and refrigerant amount: 48v DC ONLY DO NOT CONNECT AC POWER TO THIS SYSTEM Connective pipe length Less than 7.5m Air purging method Use vacuum pump Additional amount of refrigerant to be charged More than 7.5m Use vacuum pump Liquid side:6.35mm R410A: (Pipe length-7.5)x20g/m Liquid side: 9.52mm: R410A: (Pipe length-7.5)x40g/m Figure 19 Copyright 2013 HotSpot Energy 14
15 Using the Vacuum Pump FOLLOW THE INSTRUCTIONS INCLUDED WITH THE VACUUM PUMP. MAKE SURE YOU HAVE PROPER R410A FITTINGS 1.Completely tighten the flare nuts, A, B, C, D, connect the manifold valve charge hose to a charge port of the packed valve on the gas pipe side. 2.Connect the charge hose to the vacuum pump. 3. Fully open the Lo handle of the manifold valve. 4.Operate the vacuum pump to evacuate. After starting evacuation, slightly loose the flare nut of the packed valve on the gas pipe side and check that the air is entering. (Operation noise of the vacuum pump changes and a compound meter indicates 0 instead of minus) 5. After the evacuation is complete, fully close the Lo handle of the manifold valve and stop the operation of the vacuum pump. Make evacuation for 15 minutes or more and check that the compound meter indicates -76cmHg(-1.0x10 Pa). See figure Turn the stem of the packed valve B about 45 counterclockwise for 6~7 seconds after noticing gas coming out, then tighten the flare nut again. Make sure the pressure display in the pressure indicator is a little higher than the atmosphere pressure. 7. Remove the charge hose from the Low pressure charge hose. 8. Fully open the packed valve stems B and A. 9. Securely tighten the cap of the packed valve. Copyright 2013 HotSpot Energy 15
16 Safety and leakage check Performed after charging the unit 1.Soap and water method: Apply a soapy water or a liquid neutral detergent on the indoor unit connections and outdoor unit connections with a soft brush. If bubbles come out, it indicates a leak. 1. Connect the power, press the ON/OFF button on the remote controller to turn the unit on. 2. Use the MODE button to select COOL, HEAT, AUTO and FAN to check if all the functions work well. 3. When the ambient temperature is too low(lower than 17 C), the unit cannot be controlled by the remote controller to run at cooling mode, manual operation can be used Manual operation is used only when the remote controller is disable or maintenance necessary. Hold the panel sides and lift the panel up to an angle until it remains fixed with a clicking sound. Press the Manual control button to select the AUTO or COOL, the unit will operate under Forced AUTO or COOL mode (see User Manual for details). Caution A: Lo packed valve B: Hi packed valve C and D are at the ends of the indoor unit connection. 4. The test operation should last about 30 minutes. Running Test Perform test operation after completing gas leak check at the flare nut connections, and perform electrical safety check. Check that all tubing and wiring have been properly connected. Check that the gas and liquid side service valves are fully open. Copyright 2013 HotSpot Energy 16
17 Recharging the DC4812VRF All DC4812VRF units are shipped from the factory fully charged for a lineset length up to 25 ft. However, if the unit was shipped via air freight, due to air safety regulations the R410a will have been removed and replaced with a low pressure nitrogen charge. If you need to recharge an uncharged unit for this or other reason, the following instructions are provided. Evacuation Air and moisture in the refrigerant system have undesirable effects as indicated below: - Damage to compressor and valves - Pressure in the system rises. - Operating current rises. - Cooling or heating efficiency drops. - Moisture in the refrigerant circuit may freeze and block capillary tubing. - Water may lead to corrosion of parts in the refrigeration system. The indoor unit and tubing between the indoor and outdoor unit must be leak tested and evacuated to remove any non-condensables and moisture from the system before charging with R410A Freon. Evacuation with vacuum pump - Preparation Check that each tube (both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all wiring for the unit has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit. Note that both the liquid and the gas side service valves on the outdoor unit are kept closed at this stage. Completely tighten the flare nuts, A, B, C, D. Figure Using a R410A 1/4"M x 5/16"F Swivel Adapter, connect the manifold valve charge hose, (blue hose) to the charge port of the low-pressure valve on the gas pipe side. Use caution when handling the packed valve! 2. Open the valve stem until it hits against the stopper. Do not try to open it further. Replace and securely tighten the valve stem cap with a wrench. Figure 60 Copyright 2013 HotSpot Energy 17
18 Recharging (cont d) 3. Connect the yellow hose connection to the vacuum pump, red hose is not used. 4. Fully open the Blue valve of the manifold valve. 5. Operate the vacuum pump to evacuate. Check the gauge for proper vacuum. 6. Run evacuation for 30 minutes or more and check that the vacuum meter indicates -76cmHg (- 1x105Pa). After the evacuation is complete, fully close the LOW valve of the manifold valve and stop the operation of the vacuum pump. Disconnect the yellow hose from the vacuum pump and connect it to the charging tank. Figure Open the charging tank valve and place it on a digital scale inverted. Purge the manifold with gas, reset the digital scale and weigh in 1600g of Freon. If filling slows down, turn unit on and set to high cool to complete the charging. Disconnect the blue hose and replace the service caps Copyright 2013 HotSpot Energy 18
19 DC4812VRF Typical System Topology Outdoor Electrical Connections Charge Controller: HotSpot recommends and may have provided a charge controller from Morningstar: Tristar TS-45, Tristar TS-MPPT-45 or TS-MPPT-60. Information on using, installing and/or configuring these units is available for download from Regardless of the brand charge controller used, please follow the charge controller manufacturers recommended procedures. The instructions in this document are only guidelines, consult the manufacturers documents for the official information. Batteries: We recommend deep-cycle batteries from Trojan or other major manufacturer. You can use 6, 8,12 or 24 volt batteries as long as they are wired for 48 volts. HotSpot does not provide batteries. Please source your batteries from a reputable supplier and rely only upon the installation and use instructions provided by the battery manufacturer. PV Solar Panels: Solar panels must be connected per NEC and per the PV manufacturers instructions and wired according to the charge controller requirements. Mounting and grounding must follow the NEC and the instructions provided by the manufacturers of the panels, mounting & grounding hardware, etc. Ground Fault Protector (GFDI) Note this is to be a GFDI device designed to protect equipment and is not a safety device. It is NOT a GFCI. It will not protect from electric shock to a person. Use of a GFDI actually increases the safety risk and therefore must be labeled accordingly. Reference model MNEPV80 80A Din Rail Breaker & MNDC-GFP 63 3 amp Ground fault protector or similar. This is an installer-provided part. Copyright 2013 HotSpot Energy 19
20 Outdoor Electrical Connections Copyright 2013 HotSpot Energy 20
21 Battery Connections & System Overview Battery Bank Placement The battery bank should be placed as close to the load as possible. If the battery bank is placed outside, be sure to use a vented, water proof enclosure. Disconnect all wiring to and from the battery bank before maintenance or cleaning to reduce the risk of fire, shock or explosion. Always remove the negative terminal from the battery before servicing. Use caution when using a metal tool near the batteries to prevent shorts, sparks, and possible explosions. Keep all battery terminals clean and corrosion free. Do not attempt to charge a frozen battery. Always install a means of disconnect on the outside of the enclosure. Copyright 2013 HotSpot Energy 21
22 Battery Configuration Overview Always use a bus bar and ring terminals to connect the charge controller and load to the battery bank to prevent corrosion. Terminal corrosion will cause charging problems. Never connect the positive and negative to the same battery. Bus bars, ring terminals and grounding equipment is provided by the installer. Here are some examples: NOTE: The Installation of a battery bank should be done by a licensed Electrician in accordance with the NEC, and must comply with state and local standards and codes. The manufacturer accepts no responsibility for failure to follow the applicable standards and codes. It is very important that the wire you choose is large enough to carry the amount of current from your charge sources, batteries and loads or you will experience a substantial loss of energy. Undersized wire can lead to heat build up in the wire which could lead to failure of the wire and the possibility of fire and/or injury. The closer you can get your charge controller to the batteries, and the batteries to the load, the better. The longer the cable run, the larger the wire must be in order to prevent large voltage drops due to the resistance of the wire. Battery Interconnect Wiring For most battery interconnect wiring using 6 or 8 batteries, no cables should be longer than 48 and we would recommend 8 AWG wire. For 12 or 16 batteries interconnected we recommend no cables longer that 72 and use 6 AWG wire. Copyright 2013 HotSpot Energy 22
23 Solar Installation Locating the Modules / Mechanical Installation Select a suitable place for installation of the module. No parts of any of the module should be shaded at any time of the day. The module should be facing due south in northern latitudes and due north in southern latitudes for best power production. In general, for year-round usage the best elevation tilt angle for the installation will be equal to the latitude. For example if your latitude is 20 degrees, this should also be the tilt angle. Do not use module near where flammable gas may be generated or collected. General Cautions Installing solar photovoltaic systems may require specialized skills and knowledge. Installation should be performed only by qualified installers. All modules (if ordered from HotSpot) come with a permanently attached junction box and #12 AWG terminated in Multi-Contact (MC4) PV-KBT4 (female) or PV-KST4 (male) connectors. The installer should assume the risk of all injury that might occur during installation, including without limitation, the risk of electric shock. One individual module may generate DC voltages greater than 50 volts when exposed to direct sunlight. Contact with a DC voltage of 50V or more is extremely hazardous. Electrical joints such as the wire terminal could cause sparks, burning or deadly electric shock. Please do not touch such terminals directly under any circumstances. Make sure panel is covered completely to prevent it from producing electricity. When disconnecting wires from a photovoltaic module that is exposed to sunlight, an electric arc may result. Such arcs may cause burns, combustion and may otherwise create problems. Therefore, be extremely careful! Photovoltaic solar modules convert light energy into direct-current electrical energy. They are designed for outdoor use. Modules may be ground mounted, mounted on rooftops, or on a wall assuming you have obtained the proper mounting hardware. Proper design of support structures is the responsibility of the system designer and installer. Do not attempt to disassemble the module, and do not remove any attached nameplates or components. Do not apply paint or adhesive to module top surface. Do not use mirrors or other magnifiers to artificially concentrate sunlight on the module. Copyright 2013 HotSpot Energy 23
24 When installing the system, abide with all local, regional and national statutory regulations. Obtain a building permit where necessary. When installing the solar modules or repairing the air conditioner, ensure the circuit breaker on the solar panel array is in the "OFF" state. Solar modules produce electrical energy when light strikes the front of the panel. The DC voltage may exceed 30-50VDC. If the modules are connected in series, the total voltage is equal to the sum of the individual module voltages. If the modules are connected in parallel, the total current is equal to the sum of the individual module current. Keep children well away from the system while transporting and installing mechanical and electrical components. Completely cover the modules with a solid material like a blanket during installation to keep electricity from being generated. Do not touch the components or the bare ends of the wires. Do not wear metallic rings, watchbands, ear, nose, lip rings or other metallic jewelry while installing or troubleshooting photovoltaic systems. Use only insulated tools that are approved for working on electrical installations. Only perform installation in dry conditions. Abide with the safety regulations for all other components used in the system, including wiring and cables, connectors, charging regulators, inverters, storage batteries and rechargeable batteries, etc. Use only equipment, connectors, wiring and support frames suitable for use in solar electric systems. Always use the same type of module within a particular photovoltaic system. The module frame must be properly grounded. The grounding wire must be properly fastened to the module frame to assure good electrical contact. Use the recommended type, or an equivalent, connector for all grounding points. Under normal outdoor conditions the module will produce current and voltages that are different than those listed in the data sheet. Data sheet values are values expected at standard test conditions. Accordingly, during system design, values of short-circuit current (Isc) and open- circuit voltage (Voc) marked on UL series modules should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor amperage, fuse size and size of controls connected to the module or system output. The hole in the back of the module frame is used to drain the water, do not block it. Copyright 2013 HotSpot Energy 24
25 Charge Controller You may have been provided a Morningstar charge controller as part of your DC4812VRF order. If so, the following instructions should be followed. If you have a different charge controller please use the manufacturers instructions for connecting and using it. If you are using a Morningstar charge controller, following are the basic instruction for the MPPT and PWM controllers. Please make sure to download the full Morningstar manual and follow it. If there is any discrepancy between the HotSpot instructions and the Morningstar instructions, follow the Morningstar instructions or call HotSpot technical support with any questions. TRISTAR MPPT Solar System Controller Please refer to the instructions provided by the charge controller manufacturer. Following is an overview and installation tips. Figure 3-7. Power terminal locations WARNING: Be sure that the battery connection is made with correct polarity. Turn on the battery breaker/disconnect and measure the voltage on the open battery wires BEFORE connecting to the TriStar MPPT. Disconnect the battery breaker/disconnect before wiring to the controller. Please download and read the TRISTAR MPPT Operators Manual before proceeding. Copyright 2013 HotSpot Energy 25
26 Connect the four (4) power conductors shown in figure 3-7 above in the following steps: 1. Confirm that the system input and output disconnect switches are both turned off before connecting the power wires to the controller. There are no disconnect switches inside the TriStar MPPT. 2. Provide for strain relief if the bottom knockouts are used and conduit is not used. 3. Pull the wires into the wiring box. The Remote Temperature Sensor and Battery Sense wires can be inside the conduit with the power conductors. It is easier to pull the RTS and Sense wires before the power cables. 4. Connect the Battery + (positive) wire to the Battery + terminal on the TriStar MPPT. The Battery + terminal has a red cover. 5. Connect the Battery - (negative) wire to one of the Common Negative terminals on the TriStar MPPT. WARNING: Be certain that the solar connection is made with correct polarity. Turn on the solar array breaker/disconnect and measure the voltage on the open wires BEFORE connecting to the TriStar MPPT. Disconnect the solar breaker/disconnect before wiring to the controller. 6. Connect the Solar + (positive) wire to the Solar + terminal on the TriStar MPPT. The Solar + terminal has a yellow cover. 7. Connect the Solar - (negative) wire to one of the Common Negative terminals on the TriStar MPPT. Torque all four (4) power terminals to 50 in-lbs. (5.65 Nm) POWER UP WARNING: Connecting the solar array or battery connection with reverse polarity will permanently damage the TriStar MPPT. Confirm that the Solar and Battery polarities are correct. Turn the battery disconnect switch on first. Observe that the LED s indicate a successful start-up. (LED s blink Green - Yellow - Red in one cycle) Note that a battery must be connected to the TriStar MPPT to start and operate the controller. The controller will not operate only from solar input. Turn the solar disconnect on. If the solar array is in full sunlight, the TriStar MPPT will begin charging. If an optional TriStar Meter is installed, charging current will be reported along with charging state. Copyright 2013 HotSpot Energy 26
27 General Installation Cable installation should comply with all local regional and national regulations. In most countries, a ground fault protection device (GFDI) must be installed between the solar panel and air conditioner. Select a GFDI in accordance with local regulations. The electrician must identify the positive pole and negative pole. Reverse connection may cause permanent damage to the system. Use qualified photovoltaic cables only. The cable can resist UV rays and rapid climate change. The rated voltage of the cable should be more than 600V. The cross section area of the cable depends on the maximum short circuit current and the length of wire. Be very careful when installing the cable at extremely low temperature. It is recommended to use the cable of cross section area of 4mm or greater, and the wire should be as short as possible to reduce the energy consumption. Detailed Installation Instructions: If you ordered your mounting hardware from somewhere other than HotSpot Energy, consult with your supplier for detailed instructions If HotSpot Energy provided the hardware, it will either be from Iron Ridge or DPW. Please download and follow the appropriate detailed instructions. WEEB for Ironridge anual.pdf WEEB for DPW P6 anual.pdf WEEB Washers are designed to bond solar PV panels to mounting structures. The washers are made of 304 stainless steel and have teeth that embed into the aluminum mounting structure to form a gas tight electrical connection. Used as an alternative to grounding each panel with grounding lugs and ground wire., WEEBs do not ground the mounting structure to earth ground, only the panel to the frame. A ground wire must be run to each row of rails and grounded with a ground rod or the main service ground. Copyright 2013 HotSpot Energy 27
28 AC Backup & Generator Start Function Configure one or more channels to control a generator. With the flexible parameters of this Function, the user can control 1, 2, or 3-wire schemes. Refer to the generator documentation for required signals, timing, and operating specifications. This section provides a brief setup overview. Refer to the Relay Driver GenStart Supplement for detailed wiring and configuration details. The document is available on the Morningstar website at: WARNING: Remote generator control should only be configured and installed by experienced professionals. WARNING: Incorrect configuration or incorrect installation may result in personal injury, death, or damage to the generator and/or other system components. CAUTION: Configure the Relay Driver first before wiring the generator control Copyright 2013 HotSpot Energy 28
ROOM AIR CONDITIONER INSTALLATION MANUAL
ROOM AIR CONDITIONER INSTALLATION MANUAL ( Split Type) Please read this installation manual completely before installing the product When the power cord is damaged, replacement work shall be performed
SPLIT -TYPE ROOM AIR CONDITIONER
Before using your air conditioner, please read this manual carefully and keep it for future reference SPLIT -TYPE ROOM AIR CONDITIONER Please read this installation manual completely before installing
ACDC12 Solar Air Conditioner Heat Pump
ACDC12 Solar Air Conditioner Heat Pump Model ACDC12 Solar Heating & Cooling Heat Pump Mini-Split System Installation Manual Before installing or using your solar air conditioner, please print and read
Installation Guide of Sunrise Solartech PV Modules. Term 2013. Contents. Purpose of this guide. General. Safety precaution for installing a solar
Installation Guide of Sunrise Solartech PV Modules Term 2013 Contents Purpose of this guide General Safety precaution for installing a solar Photovoltaic system Product Identification Mechanical Installation
Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
Ductless Split Air Conditioner
Ductless Split Air Conditioner Installation Manual Indoor HSU09VHG(DB)-W HSU12VHG(DB)-W HSU18VHH(DB)-W HSU24VHG(DB)-W Outdoor HSU09VHG(DB)-G HSU12VHG(DB)-G HSU18VHH(DB)-G HSU24VHG(DB)-G Table of Contents
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Room Air Conditioners
Installation Manual Room Air Conditioners R410A Split Type Y Series DC INVERTER ECO940SD ECO1240SD ECO1840SD Please read this installation manual completely before installing the product. When the power
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
Reverse Cycle Inverter Split System Air Conditioner
Reverse Cycle Inverter Split System Air Conditioner Model Number TAC-09CHSA/JAI5 INSTALLATION MANUAL Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 06 Product Overview 07 Selecting
MCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
RAY-MAX Integrated Solar Power Strip
RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings
*** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide
SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide circuit. Reverse connection will damage the module and may result in fire. CAUTIONS Solar electric modules produce DC electricity
AIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
LG Floor Standing Type Air Conditioner INSTALLATION MANUAL
website http://www.lgservice.com e-mail http://www.lgeservice.com/techsup.html LG Floor Standing Type Air Conditioner INSTALLATION MANUAL LG IMPORTANT Please read this installation manual completely before
Air Conditioner Water Heater Model ACWH18
Air Conditioner Water Heater Model ACWH18 Installation Guide IMPORTANT! READ THIS FIRST! Commissioning of this unit must be done by a licensed HVAC technician. Commissioning includes making the electrical
LUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
How To Plan Out An Array Of Solar Panels
CITY OF DOWNEY COMMUNITY DEVELOPMENT, BUILDING AND SAFETY 11111 Brookshire Avenue Downey, CA 90241 562.904.7142 (www.downeyca.org) B SECTION 01/01/2011 EFFECTIVE DATE PHOTOVOLTAIC 032 FORM NUMBER 2013
User Manual. Hybrid 1KW-5KW INVERTER / CHARGER. Version: 1.1
User Manual Hybrid 1KW-5KW INVERTER / CHARGER Version: 1.1 Table of Contents ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Product Overview... 3 INSTALLATION...
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,
AIR CONDITIONER INSTALLATION MANUAL
INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by
Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
Installer s Guide 18-AH39D1-13
18-AH39D1-13 Cased Aluminum "Convertible" Coils 4TXCA018BC3HC** 4TXCA024BC3HC** 4TXCB025BC3HC** 4TXCB026BC3HC** 4TXCB031BC3HC** 4TXCB032BC3HC** ALL phases of this installation must comply with NATIONAL,
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:
ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS: Chapter 12 of the Burlington Code of ordinances allows owner occupants of single family homes to do their own wiring if they choose. If you choose to
Installation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit
PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
DLP-PU/E Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS High Wall Mounted Ductless Split Type Air Conditioner WL-WT-WG-WH Series IDU Matched with AN-YN Series ODU WAL, WAT, WAH, WAG Cool Only WYL, WYT, WYH, WYG Heat Pump After-sales
AIR CONDITIONER INSTALLATION MANUAL
FRANCAIS ESPAÑOL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring
IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
SDX Submersible Depth Transmitter User Manual
SDX Submersible Depth Transmitter User Manual January 2011 USER INFORMATION Stevens makes no warranty as to the information furnished in these instructions and the reader assumes all risk in the use thereof.
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716
BATHROOM HEATER User's Manual Page 2...A515 Page 9...A716 BATHROOM HEATER User's Manual A515 SAVE THESE INSTRUCTIONS AND READ ALL INSTRUCTIONS BEFORE USING THE HEATER. Dear customers, Thank you for selecting
Installation Instructions for Alarm Module Kit A043F059
Instruction Sheet 07-2013 Installation Instructions for Alarm Module Kit A043F059 1 Introduction The information contained within is based on information available at the time of going to print. In line
WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:
Revision Level: 01 Revision Date: 07/07/2011 Please read all instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Air Purifier. Failure to do
Hi Wall Split Air Conditioners
R22 220-240V ~, 50Hz Hi Wall Split Air Conditioners 53KHET 12-18-24 Cool Only 53QHET 12-18-24 Heat Pump INSTALLATION MANUAL Carrier is committed to continuously improving its products according to national
Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual
Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual 255379 Rev. D0 1015 Printed in U.S.A. Copyright 2015 Federal Signal Corporation Limited Warranty The Alerting and Notification
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual
Operation and Maintenance Manual Introduction Read all instructions thoroughly. Installation of the OilTector must comply with all Federal, State and Local Codes, Regulations and Practices. The OilTector
OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
5800 Temperature Sensor Cable Assembly
5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety precautions should always
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
Inverter Room Air Conditioner Installation Manual KSV26CRE, KSV26HRE, KSV35CRE, KSV35HRE, KSV53HRE, KSV62HRE, KSV70CRE, KSV70HRE, KSV80HRE
Inverter Room Air Conditioner Installation Manual KSV26CRE, KSV26HRE, KSV35CRE, KSV35HRE, KSV53HRE, KSV62HRE, KSV70CRE, KSV70HRE, KSV80HRE Refrigerant R32 Congratulations Contents Congratulations and thank
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION
INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions
CEILING CASSETTE FAN COIL UNIT
CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and
Floor Type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA. English
Floor Type Air-Conditioner MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA INSTALLATION MANUAL This manual only describes the installation of indoor unit. When installing the outdoor unit, refer to the installation manual
UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video
UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video http://bit.ly/9ywwh! CAUTION MAKE SURE NO OBSTACLES ARE IN THE DESK S PATH AND ALL
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions
Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129
PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: The information included in this Splendide Repair Manual may change without notice. Please see our web site www.splendide.com/service/docs.html for updates,
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
TS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5
AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS INSTALLATION HANDBOOK
SPLIT WLL MOUNTED TYPE IR CONDITIONERS INSTLLTION HNDBOOK Thank you for choosing our ir Conditioner. Please read this INSTLLTION HNDBOOK carefully prior to installing and keep it for further reference.
INSTALLATION INSTRUCTIONS SINGLE SPLIT WALL MOUNTED AIR CONDITIONER
INSTLLTION INSTRUCTIONS SINGLE SPLIT WLL MOUNTED IR CONDITIONER Please read this instruction sheet completely before installing the product. When the power cord is damaged, replacement work shall be performed
Contractors Guide Central Inverter System Installation
Contractors Guide Central Inverter System Installation Step By Step Procedures 2,200 Watt/VA 6 Step Installation 1. Mount Bottom Cabinet 2. Mount Top Cabinet 3. Install Batteries 4. Install Conduit 5.
2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE
2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE PAGE 1 OF 5 This Reference provides a very comprehensive list of aspects of a solar PV installation that could be reviewed, clarifying
What are the basic electrical safety issues and remedies in solar photovoltaic installations?
What are the basic electrical safety issues and remedies in solar photovoltaic installations? Presented by: Behzad Eghtesady City of Los Angeles Department of Building and Safety Topics Covered Photovoltaic
AerAtron. Ceiling fans
AerAtron Ceiling fans User Manual & Technical Specifications Models: e502 & e503 Electricians PLEASE FOLLOW THESES INSTRUCTIONS CAREFULLY & PAY SPECIAL ATTENTION TO THE NOTES NOTES WILL ASSIST WITH AN
TruPower-Portable-500W. Solar Starter kit
TruPower-Portable-500W Solar Starter kit This Solar starter kit is an easy to use solar power supply system that is the complete solution for all your solar power needs. It is a solar generator that converts
Series 510 Submersible Level Transmitters
Series 510 Submersible Level Transmitters The Series 510 Submersible Level Transmitters are solid state instruments designed for direct submergence into many types of liquid for quick, accurate and reliable
Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.
Model Number: Serial Number: Information Manual Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters. ATTENTION: IF YOU ARE NOT A LICENSED PLUMBER OR A LICENSED
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR
INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
Install Guide CT101. Caution. Caution
Install Guide CT101 PG 1 Caution top cover Your thermostat is a precise instrument, handle it with care. Turn off electricity to the system before installing or servicing thermostat or any part of the
LED MOTION ACTIVATED FLOOD LIGHT
Utilitech & UT Design are registered trademarks of LF, LLC. All Rights Reserved. ITEM #0611551, #0611550 LED MOTION ACTIVATED FLOOD LIGHT MODEL #SE1036-BP2-02LF0-U, SE1036-WH3-02LF0-U Français p. 10 Español
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.
ENGLISH ESPAÑOL INSTALLATION MANUAL ELECTRIC RANGE Please read these instructions thoroughly before installing and operating the range. LRE3025ST LRE3085ST LRE3083ST LRE3083SB LRE3083SW LRE3021ST LDE3037ST
Inverter Air Conditioner Installation Manual. KSV25CRF, KSV35CRF, KSV70CRF, KSV25HRF, KSV35HRF, KSV52HRF, KSV70HRF, KSV80HRF Refrigerant R32
Inverter Air Conditioner Installation Manual KSV25CRF, KSV35CRF, KSV70CRF, KSV25HRF, KSV35HRF, KSV52HRF, KSV70HRF, KSV80HRF Refrigerant R32 Congratulations Contents Congratulations and thank you for choosing
AerAtron. Ceiling fans
AerAtron Ceiling fans User Manual & Technical Specifications Models: e502 & e503 Australian edition 2011 Instructions...3 General precautions...3 Location and installation requirements for your fan...3