Tobin Center for the Performing Arts
|
|
|
- Joella Quinn
- 10 years ago
- Views:
Transcription
1 Tobin Center for the Performing Arts Building 6 (Over 75 Million Dollars) Project Description The Project consisted of the complete renovation of the historic Municipal Auditorium s treasured façade while incorporating a new 183,000 square foot, six story, and multipurpose performance arts hall into its framework. The Municipal Auditorium was originally constructed in the late 1920 s and was dedicated to World War 1 veterans. The north side of the site borders the San Antonio River Walk and contains a plaza where Medal of Honor recipients who had an association with San Antonio are honored. In the spring of 2011 Linbeck / Zachry Joint Venture was selected as the Construction Manager at Risk on the project. The Linbeck / Zachry Joint Venture was formed to combine the strengths of two 75 year old companies and local contracting experience. The Linbeck team brought large, complex and performing arts experience together with Zachry's extensive San Antonio and complex project experience to form a cohesive integrated project team. Linbeck / Zachry Joint Venture s early involvement in preconstruction services allowed the Owner to realize some savings options that led to greater program opportunities. During the preconstruction phases we priced numerous design schemes for the size and architecture of the building in order to select the optimum design solution for the project. Those schemes included the total tear down of the Municipal Auditorium and the "raising of the existing roof" which would renovate the existing building. Ultimately integrating the historical façade and entry with a new structure adjacent to the old was deemed 1
2 the most viable. Our contract with the client was a guaranteed maximum amount with fee at risk. The terms included savings to be returned to the client. We were able to manage the cost so that we identified savings that were returned early and the client was able to add enhancements during the course of the project. Difficulty in construction resulting from design, location, materials; The newly opened Tobin Center for the Performing Arts is more than a state-of-the-art performance venue rivaling the best in the world. It was also a case study in complex construction projects. The Linbeck Zachry JV faced a multitude of unique situations in constructing the ultra-modern facility, which includes a 1,750-seat performance hall, a 250-seat studio theater and an outdoor performance plaza. Performance Hall inside an Existing Structure: The team built the new center inside an existing historic structure, in an extremely tight footprint in busy downtown San Antonio, on the edge of the San Antonio River, while meeting the strict requirements necessary for construction of a world-class venue for music and theater. 2
3 Performance halls by their very nature are some of the more complicated construction projects, the preservation of a portion of the original structure and its integration with a completely new, state-of-the-art performance center made this an even more challenging project. The construction process, which began in May 2011 and culminated with the doors opening on September 2014, was a painstaking exercise in precision. That began with the demolition of the Municipal Auditorium while preserving the building s original Spanish Colonial Revival-style front and side façades. Downtown Location: The location of the Center created additional challenges. First, the job site had an extremely tight footprint in a congested area of downtown San Antonio. There was no laydown area for the temporary storage of supplies. Both firms are strong supportters of LEAN CONSTRUCTION principles and are experienced in the use of the LAST PLANNER. These construction management techniques were used throughout the project. Delivery of materials were completed on a strict just in time basis so they could be installed soon after arrival. The site had three acres of property and 2.5 acres of building. This extremely tight footprint required the team to closely coordinate manpower, equipment, and material deliveries. Secondly because we were on the San Antonio River and near multiple active businesses we had to make valiant efforts to be good neighbors during construction. Examples include a vehicle wash station that all vehicles exiting the site had to go through, shrouding of light fixtures on the tower cranes to minimize light pollution, late morning demolition start to minimize noise issues, and maintenance of street/ fences for egress into and around the site. On the River: The site s position on the south bank of the San Antonio River meant that piers and sub-foundations were below the river level. We lowered the water table within the building footprint by use of pumps. This created a dry work area for the foundation work. The water discharged from the construction was all run through a process of filters and settlement tanks before allowing discharge into the river. Differing Site Conditions: Early in the project before demolition of the existing building was to begin a differing site condition was discovered that had the potential of a significant delay. It was discovered that a major high voltage, buried, electrical transmission line traversed the site. The existing location would pass thru the new building's lower level. We ultimately developed a construction sequence that allowed the demolition of the existing building and the excavation for the new building to commence without a significant delay to the project schedule. By working with our trade partners we were able to eliminate any additional construction cost to the Owner. 3
4 Unusual Construction Techniques Involved Existing Structure Reinforcement- Movement Monitoring The team reinforced the U-shaped façade to help it withstand the demolition of the rest of the auditorium. Throughout the demolition and through the structural steel and concrete construction stages we monitored the existing limestone for vibration and movement. This was done by the installation of vibration gauges and laser surveying of the existing building before the constructing began and then after it was complete. No detrimental movement occurred. Laser Scan and Modeling While 3D modeling is increasingly common in construction, it was a necessity for this project due to the complexity of tying into the existing historic piece. The team elected to complete a full 3D laser scan of the historic structure, which was then formatted into a fully integrated model. This allowed the trade partners and the design team to coordinate how the structure and rooflines would tie together into existing ones. Linbeck / Zachry Joint Venture closely coordinated the modeling effort with all of the trade partners on site with weekly modeling reviews. The entire structure was built three-dimensionally in the model prior to fabrication and field installation. Linbeck / Zachry Joint Venture employees conducted BIM coordination meetings weekly on the job site for over nine months. This coordination effort was used to fabricate the structural steel and to fabricate and install the ductwork, pipework and electrical conduit. This process eliminated major "clashes" in the field and resulted in a more productive installation. 4
5 Unique Acoustical Requirements The complex important acoustical requirements command the attention of almost all construction processes performed. The air conditioning systems are to only be felt, not heard, in a concert hall. To achieve that, the air velocity is very low and therefore the distribution systems are larger than normal. The ductwork is all internally insulated and most are enclosed in an acoustical enclosure to further manage unwanted noise. Electrical and fire protection systems on most project types are installed generally in the shortest and most direct route. The goal in a performance hall is to accomplish the same thing; however given the architecture of the building with the high ceilings and open areas in the audience chamber and stage house that path involves many twists and turns to get to the required location. Primarily for acoustical reasons interior partitions are constructed from floor to the structure above verses merely above the ceiling. The intersection of the partition to the structure is treated with a special detail for acoustical and/or fire and smoke control. Special details are implemented when pipe, ducts, and conduits must pass through the acoustical rated walls and floors. All of the preceding systems and items require close coordination to be able to fit within the minimal spaces allocated and the architecture demands for the project. Education to the Craftsman Due to the infrequent construction of this building type within a local area; the craftsmen and subcontractors are not familiar with the unique construction requirements. Given our experience in constructing performance arts halls; we recognize that lack of familiarity and took great effort to educate the subcontractors and the craftsmen of the special needs for this project. We produced specific instructions to bidders in our invitation to bid packages defining exactly how the work needed to be performed. Once the subcontractors were on site; we introduced them to the unique terminology required to effectively understand the building type. Examples are "AIJ " Acoustical Isolation Joint, a very critical item for isolating sound which might transfer through the structure; the difference between "house left" and "house right" verses "stage left" and "stage right". These informational sessions were conducted in concert with the specialty consultants; the acoustician and the theatrical consultant. Operable Floor System The Tobin Center is unique in that it also includes a $10 million moving flooring system, the first of its kind in the nation, consisting of rows of seats on a series of lifts that allow the seating configuration to go from a flat floor to a raked configuration at the push of a button. Increased uses result in increased revenue. A moveable floor allows the seats in a typical audience chamber "sloped" configuration to be mechanically rotated and stored under the floor. The floor can then be reconfigured into 12 predetermined configurations. The most frequent configuration is a flat floor that is raised to the stage 5
6 floor level so that the chamber and stage floor are one large contiguous floor. This configuration allows for banquets, trade shows and other events where a flat floor is desired. The floor utilizes existing spiral lift technology, typically used to elevate orchestra lifts. Added to that technology are moveable bases which the fixed theater chairs are attached. These bases rotate and allow the chairs to be stored below the floor. Gala Systems from Canada was hired to design, fabricate and install the moveable flooring system. Their design and construction work had to be coordinated with multiple disciplines starting with the structural slab at grade and continuing through the installation of flexible fire detection and suppression systems. Those systems can function in any of the floor configurations. Construction challenges began with coordinating the 30 spiral lift locations with the 15" thick concrete slab that contained 2'- 6" deep beams at the location of the lifts. During the reconfiguration the seats rotate on a base and are stored upside down under the floor. This required detailed engineering and coordination with the seating manufacturer, Series Seating. The biggest challenge with the seats is that when they rotate the seat pans stay in a vertical position and do not become horizontal. Becoming horizontal will put them in the way of the adjacent moving floor and damage the seat. The finish floor material for this system is an engineered wood floor system. The wood was installed to allow for the minimum clearance between the lifts of 1/4". The gap from the end of the each lift to the adjacent wall was also 1/4". This floor installation required close coordination with other aspects of the project since it could not be installed unless the humidity within the chamber was controlled to prevent expansion of the floor material during and after its installation. The supply air for the chamber occurs through 300 floor grilles. These also had to be coordinated with the operable floor system. The transformation between configurations takes approximately 25 minutes. The floor has been reconfigured numerous times since the building opened and different events have been held with different floor configurations in the same day. The installation of the system at the Tobin has been a huge success. 6
7 Operable floor system (photos) Building Cross Section of Operable Floor Raked Seating Configuration Flat Floor Configuration 7 Gala Configuration
8 Final Appearance and Quality of the Finished Product World Class Facility to Rival any Performance Hall in the World was the Goal. The expectation of the quality of construction was established early on from everyone involved. The design team had very specific requirements on the final quality and appearance. Given our experience, we knew the most difficult detail to construct was the fascia on the audience chamber balcony fronts. These not only function as an architectural element but also as an important part of the acoustical design of the audience chamber and provide fall protection to the occupants. The fascias were constructed of perforated wood panels backed by an acrylic panel with LED lights behind. This component must comply with strict code compliance for handrail height while not conflicting with the seating sight lines. The initial design of the fascia at Tobin was to prefabricate millwork "light boxes" that would be assembled off site. We developed details that would allow for a more constructible approach to handle construction tolerances of the concrete and steel structure including deflection that would occur in the cantilevered balconies. The final installation is in strict code compliance, provides for the desired sight lines, is a stunning architectural feature, and was installed without rework due to unforeseen issues with the structure. 8
9 Timeliness of Completion The date for the opening performance was established early in the construction process. We achieved substantial completion and occupancy of the building two days before that established in our contract. The grand opening event occurred on September 4, 2014, on schedule and was a huge success. We were able to achieve this ambitious schedule established at the beginning of the project inception despite the JV processing over 2,200 submittals, 560 items of change and 1,200 Requests for Information. The Performance Hall was built on time, in budget, incorporating cutting edge technology while maintaining the original historical significance of the Municipal Auditorium. 9
The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE
The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE BUILDING SERVICES DEPARTMENT 789 Broadway Street, Box 3000 Wyoming, ON N0N 1T0 Telephone: 519 845-0801 Toll-free: 1-866-324-6912 Fax: 519
Electrical. This section applies to the design and installation of building power distribution systems.
Basis of Design This section applies to the design and installation of building power distribution systems. Design Criteria This section contains the architectural, structural and mechanical provisions
Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS
Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS 1009.1 Stairway width. The width of stairways shall be determined as specified in Section 1005.1, but such width shall not be less than 44
REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N
PLAN REVIEW FOR: PROJECT NAME: OWNER: ARCH/DESIGNER: ADDRESS: Ph/Fx: Plans Dated: E-mail: Sealed By: Estimated Project Cost - $ REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N
Building Code Clarifications - 7. Fire Resistance
Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,
All substantial design decisions and budget confirmation shall be resolved for the College to approve the Design Development Submittal.
2.02 DESIGN DEVELOPMENT PHASE GENERAL The Architect shall prepare the Design Development Documents from the approved Schematic Design. The Design Development Documents shall consist of drawings and other
BUILDING PERMIT SPECIFICATIONS
BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide
Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders
INTRODUCTORY INFORMATION TABLE OF CONTENTS 00 0101 PROJECT TITLE PAGE PROCUREMENT REQUIREMENTS (PROJECT MANUAL) Tab A - Invitation for Bids Tab B - Instructions to Bidders Tab C Bid Form for General Bids
Exterior Elevated Elements Inspection Guidelines
Exterior Elevated Elements Inspection Guidelines Planning and Development 1. Guideline Purpose These guidelines are intended to assist practicing professionals in complying with Berkeley Municipal Code
Area of Rescue Assistance Communication System ADA Code Applicable excerpts:
Area of Rescue Assistance Communication System ADA Code Applicable excerpts: CONTENTS (Guidelines and Definitions) Page 1 Area of Rescue Assistance Requirements Page 2 Emergency Communication Equipment
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 MINORITY AND WOMEN S BUSINESS ENTERPRISE PARTICIPATION
Architectural Acoustics
Excerpt from The Architect s Handbook of Professional Practice, 13th edition, 2000 Architectural Acoustics Christopher Jaffe, Ph.D., Hon. AIA, and Russell A. Cooper Architectural acoustical services encompass
Certification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
Lighthouse Engineering, L.L.C.
Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website: www.lighthouseeng.com Email: [email protected] Thursday, September 04, 2014 TO: Our Client RE: Initial Engineering
Peninsula Place, Greenwich, London
Concepts Products Service Peninsula Place, Greenwich, London 1 Project Report Peninsula Place, Greenwich, London Designed as one of the most sustainable commercial buildings in the UK, with a BREEAM rating
Building Codes Update: The 2009 International Fire Code and the Apartment Industry
! Building Codes Update: The 2009 International Fire Code and the Apartment Industry Apartment operators and developers should be aware of organizational changes in the 2009 edition of the International
COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP
COLUMN-FREE OFFICE SPACE RISES IN CHICAGO S LOOP 30 x45 bay provides maximum tenant flexibility and increases leasing marketability By David E. Eckmann AIA, S.E. P.E. SURGING DEMANDS FOR RENTABLE OFFICE
Hanson Building Products. precast basement solutions
Hanson Building Products precast basement solutions Hanson Building Products Basement Systems Add an extra dimension and combine the inherent flexible, structural and waterproof properties of concrete
Design Development Quality Management Phase Checklist Project Phase Checklist Series
Best Practices Design Checklist Project Phase Checklist Series Contributed by Micheal J. Lough, AIA, Principal, Integral Consulting The AIA collects and disseminates Best Practices as a service to AIA
Occupancy: Assembly (A-3) and Business -Includes offices, seminar rooms, classrooms, and café facility. Duke University Medical School
Introduction Background The Duke School of Nursing building offers a new three-story state of the art facility that has helped strengthen the quality and integrity of the School of Nursing at Duke. The
CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST
CITY OF BERKELEY DETAILED CHECKLIST This checklist will assist you in preparing plans for submittal with a building permit application. Alterations, additions and remodeling projects may not require all
The work has continued on final Phase 4 and is nearing completion.
Updates-January 22, 2013 29369-Rehab Plaza Deck/Drainage Budget: $18,000,000, constr. Start 8/2009 The work has continued on final Phase 4 and is nearing completion. The main plaza area of phase 4 is now
Acoustical Design for Concert Hall in the Science and Art Centre of Xiamen University
Acoustical Design for Concert Hall in the Science and Art Centre of Xiamen University Yuezhe Zhao, Shuoxian Wu State Key Laboratory of Subtropical Building Sciences, South China University of Technology,
Linbeck Construction used the Last Planner system of production control on a $22 million remodel of the Chemistry Building at Rice University.
Linbeck Construction used the Last Planner system of production control on a $22 million remodel of the Chemistry Building at Rice University. This was one of four innovative practices was described by
ENTRY FORM. DVASE 2013 Excellence in Structural Engineering Awards Program
ENTRY FORM DVASE 2013 Excellence in Structural Engineering Awards Program PROJECT CATEGORY (check one): Buildings under $2M Buildings Over $100M Buildings $2M-$10M Other Structures Under $5M Buildings
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: SECTIONS 1, 2, 3, AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION
BUILDING SAFETY UNIT
POLICY Page 1 of 5 SUBMITTAL REQUIREMENTS FOR ONE AND TWO FAMILY DWELLINGS, ADDITIONS AND RENOVATIONS All submittals shall be site specific and designed to the provisions of the 2012 International Residential
www.maurerarchitecture.com
Design Guidelines, Historic Districts and Codes as Downtown Development Tools The NC Rehab Code and Its Benefits for Older Buildings North Carolina Main Street Conference January 25-27, 2012 History of
MILWAUKEE CITY HALL FOUNDATION RESTORATION. Project Update November 12, 2014
MILWAUKEE CITY HALL FOUNDATION RESTORATION Project Update November 12, 2014 Milwaukee City Hall Building History/Fast Facts - City Hall is a masonry and iron superstructure - Originally constructed from
Industrial Suburban District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations
16.20.110 - Industrial Suburban District ( IS ) Figure REFERENCE Typical Buildings in the IS District Figure REFERENCE Site Plan of a typical development in the IS District Sections: 16.20.110.1 Composition
OCFRD TENT STANDARD 6000. This Standard operates under the authority of Orange County, Florida Ordinance and State Statutes.
1. Authority Orange County Fire Rescue Department Tents & Membrane Structures Office of The Fire Marshall - 109 E. Church Street, Lower Level - Orlando, Florida 32801-3319 Phone: 407-836-0004 Fax: 407-836-8310
9770 CULVER BOULEVARD CULVER CITY, CA 90232-0507 www.culvercity.org. Incidental improvements: improvements that do not qualify as minor or
9770 CULVER BOULEVARD CULVER CITY, CA 90232-0507 www.culvercity.org Construction Permitting Guidelines for Businesses Moving into Existing Buildings in Culver City If your business is moving into an existing
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011
GYPSUM AREA SEPARATION FIREWALLS GA-620-2011 GA-620-2011 Copyright 2011 Gypsum Association All rights reserved. Printed in U.S.A. Characteristics, properties, or performance of materials or systems herein
Building Code Inspections and Fees
St. Mary s County Department of Land Use & Growth Management Customer Assistance Guide 22 Building Code Inspections and Fees May 10, 2014 This guide is intended to assist in the proper construction sequence
REQUEST FOR BOARD ACTION HENDERSON COUNTY BOARD OF COMMISSIONERS. ATTACHMENTS: 1. Construction Management Update
REQUEST FOR BOARD ACTION HENDERSON COUNTY BOARD OF COMMISSIONERS MEETING DATE: March 16, 2011 SUBJECT: PRESENTER: ATTACHMENTS: Construction Management Update David Berry Yes 1. Construction Management
Case Studies. Disaster Recovery Restoration Remediation Decontamination 800.808.1553 www.rolyncompanies.com
Case Studies 800.808.1553 www.rolyncompanies.com Property Type: Condominium Loss Type: Water and Flood Location: Ashburn, Virginia Rolyn placed containment in each unit to carefully block any drywall dust
City of St. Charles Basement Finish or Remodel
City of St. Charles Basement Finish or Remodel Building & Code Enforcement Division 2 East Main Street St. Charles IL 60174 630.377.4406 (Office) 630.443.4638 (Fax) http://www.stcharlesil.gov Please direct
Excerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No.
Classification: Cluster: Location: Total Area: No. of Stories Aquarium Acreage Owned: Acquired: 1904 Most Recent Improvements: THE AQUARIUM Close to junction of Inselrhue and Loiter Way, Belle Isle Two
SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST
SODA SPRINGS JOINT SCHOOL DISTRICT NO. 150 RECOMMENDED REPAIRS, REPLACEMENT, AND ADDITIONS OPINIONS OF PROBABLE COST SODA SPRINGS HIGH SCHOOL REPAIRS AND UPGRADES SITE Construction Estimate = $100,000
Current as of 11/10/08 1 of 1
BEST PRACTICES STANDARDS FOR SCHOOLS UNDER CONSTRUCTION OR BEING PLANNED FOR CONSTRUCTION I. Site Layout A. School buildings shall be provided with a securable perimeter. A securable perimeter means that
HIGH LEVEL SEISMIC UPGRADE COST ESTIMATE FOR CENTRE BLOCK, PARLIAMENT HILL
HIGH LEVEL SEISMIC UPGRADE COST ESTIMATE FOR CENTRE BLOCK, PARLIAMENT HILL Prepared for: Public Works and Government Services Canada Parliamentary Precinct Branch Prepared by: Halsall Associates 210 Gladstone
National Home Builder - Name Wednesday, August 20, 2014 Regional Customer Care Manager 1234 Main Street Houston, Texas 77067
Lighthouse Engineering, L.L.C. Michael Gandy, P.E. Registered Professional Engineer (TX: 95672) Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website: www.lighthouseeng.com
GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)
GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA) Chapter 1 : Definitions clause 1.2.10 : circulation space OLD CLAUSE A space mainly used as means of access between a room or protected shaft
2012 BIM Guidelines and Standards (Rev. 00) University at Albany
A. Building Information Modeling (BIM) Guidelines: The Office of AECM will require the submission of BIM modeling files as part of an electronic file submission to the AECM project manager as requested
Chapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
Elevating Your House. Introduction CHAPTER 5
CHAPTER 5 Elevating Your House Introduction One of the most common retrofitting methods is elevating a house to a required or desired Flood Protection Elevation (FPE). When a house is properly elevated,
King Post Wall Information
King Post Wall Information DAWSON-WAM specialise in the installation of piled retaining wall systems including steel sheet piling, concrete piled walls and king post walls. This document is our guide to
When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:
When is a Permit Required? The most common types of projects that require permits are: -New Houses or buildings -Room Additions or Expansions -Structural repairs, remodeling and alterations -Accessory
H:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh
Accessory Apartment Construction Guide For Single Detached Dwelling and Semi-Detached Dwellings that have been in existence for at least five (5) years Notes: Buildings that are less than five (5) years
Lighthouse Engineering, L.L.C.
Wednesday, August 20, 2014 Lighthouse Engineering, L.L.C. Michael Gandy, P.E. Registered Professional Engineer (TX: 95672) Registered Engineering Firm (F: 9334) Phone: 214-577-1077 Fax: 214-224-0549 Website:
WARRANTIES AND PERFORMANCE STANDARDS T A B L E O F C O N T E N T S General Provisions Introduction Warranties Effective Date of Warranties Exclusive
WARRANTIES AND PERFORMANCE STANDARDS T A B L E O F C O N T E N T S General Provisions Introduction Warranties Effective Date of Warranties Exclusive Warranties Time Limits for Reporting Manufacturer s
Construction Technologies Career Field Pathways and Course Structure
Courses in Structural Systems (DD) Construction Technologies Career Field Pathways and Course Structure PATHWAY COURSES SUBJECT CODE Construction Technology-Core and Sustainable Construction 1 178000 Carpentry
SECTION 00 0110 TABLE OF CONTENTS. H. 00 2115.01 - Proposed Material, Product or Equipment Substitution Request
SECTION 00 0110 PROCUREMENT AND CONTRACTING REQUIREMENTS 1.1 DIVISION 00 -- PROCUREMENT AND CONTRACTING REQUIREMENTS A. 00 0101 - Project Title Page B. 00 0105 - Certifications Page C. 00 0110 - Table
API AIMM PHILADELPHIA INSTALLATIONS FURNITURE INSTALLATIONS RECONFIGURATION RELOCATION PROJECT MANAGEMENT WAREHOUSING
API AIMM PHILADELPHIA INSTALLATIONS FURNITURE INSTALLATIONS RECONFIGURATION RELOCATION PROJECT MANAGEMENT WAREHOUSING API ABOUT US AIMM Philadelphia Installations Inc. is a furnishings installation, millwork,
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
May 5, 2010. Client Client Address. Re: Inspection Address, Chicago, Illinois. Dear Mr. Client,
PROPERTY INSPECTION PROFESSIONALS May 5, 2010 Client Client Address Re: Inspection Address, Chicago, Illinois Dear Mr. Client, On May 4, 2010, Tomacor completed a property inspection of the above referenced
DAYBREAK ATTACHED RESIDENCE DISCLOSURE STATEMENTS Acknowledgement of Receipt Form
Builder Name: Lot Number: Page 1of 6 DAYBREAK ATTACHED RESIDENCE DISCLOSURE STATEMENTS Acknowledgement of Receipt Form These disclosure statements (the Attached Residence Disclosure Statements ) are provided
2. What building projects are exempted? (permit not required)
BUILDING AND SAFETY DEPARTMENT 1. What building projects require a permit? Following is a list of projects that require building permits based on Appendix chapter 1 of the California Building Code and
EAST LYME HIGH SCHOOL
Overview: 1971 N 1966 GYM 1966 CLASSROOM WING 1966 AUD. 1971 GYM 1998 1998 POOL EAST LYME HIGH SCHOOL Original 1966 Building: The original East Lyme High School was constructed in 1966 and was composed
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
CITY OF SELMA, TEXAS Inspection Checklist: Commercial
Rev Y71004 The Permits and Inspections Department welcomes you to the City of Selma. The following information is provided to you as guidance through the inspection process. The City of Selma provides
Residential Building Permits
LANE COUNTY PUBLIC WORKS Residential Building Permits LAND MANAGEMENT DIVISION 3050 N. DELTA HWY, EUGENE OR 97408 i CONTACT PHONE NUMBERS: Building Program: (541) 682-4651 Inspection Requests: (888) 299-2821
9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.
Section 9.8. Stairs, Ramps, Handrails and Guards 9.8.1. Application 9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and
St. John s University
St. John s University Fire Safety Plan Founder s Village Townhouses Page 1 St. John s University Fire Safety Plan Part 1-Building Information Section Founder s Village Townhouses 8000 Utopia Parkway Jamaica
Integrated Solar Radiant Systems
Integrated Solar Radiant Systems William Shady PE President Topics Radiant heating Indoor air quality Radiant Cooling Project Photos Questions and answers The goal for our clients Healthy Comfort Why Radiant
National Archives and Record Administration
National Archives and Record Administration Installation of Self-Closing Flood Barriers and Loading Dock Turntable Removal and Structural Slab Repairs ! 2010 Baltimore Washington Chapter Outstanding Repair
Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components
Infrastructure Facility Condition Summary Weighted Avg Condition Score Facility Components Systems Surveyor/ Date Done Comments G Sitework.9 Site Improvements Parking Pedestrian Paving Site Development
WHEN IS A PERMIT REQUIRED?
WHEN IS A PERMIT REQUIRED? Any owner, builder, contractor, or other authorized agent who intends to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure,
CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION
CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION SPECIFICATION EO-5023 REVISION 3 MARCH 2003 REQUIREMENTS FOR
How To Repair A House
Assessing Structural Damages Please note-this presentation is only intended to be used as a basic educational tool and is by no means all encompassing. Each property should be treated on a case by case
This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G
100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G The Opportunity Jones Lang LaSalle, Inc. (the Broker ) is please to offer the fee simple interest in 100 Locust Avenue (the
TOWN of NEW BOSTON. Bid Package. Refurbishment and Upgrade of Basement of the New Boston Town Hall
TOWN of NEW BOSTON Bid Package Refurbishment and Upgrade of Basement of the New Boston Town Hall Your bid Envelope must be marked with Basement Upgrade at Town Hall and the due date and time. If you send
10' 16' Maximum. Backwall 5' 5'
Peninsula December 11 13, * ALL PENINSULA EXHIBITORS ARE REQUIRED TO SUBMIT ACCURATE RENDERINGS AND DIMENSIONS OF THE PENINSULA EXHIBIT TO TRADE SHOW MANAGEMENT FOR APPROVAL PRIOR TO THE SHOW. (For questions,
Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT
Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE Sec. 58.1. Division D-O occupancies. 58.2. Separation and mixed occupancy. OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM
Planning a Soundproof Performance Building Within Budget. Education Session #5, Track 3 October 06, 2015, 11:15 AM 12:15 PM
Planning a Soundproof Performance Building Within Budget Education Session #5, Track 3 October 06, 2015, 11:15 AM 12:15 PM Presenters Eric Norman VP of Finance & Planning The Boston Conservatory Mimi Love
Element D Services Plumbing
PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses domestic cold, hot and hot water return distribution systems within and to five feet beyond building perimeter. PART 2 - DESIGN CRITERIA 2.01 GENERAL
City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage
City of Treasure Island FEMA Cost Breakdown Worksheet For Substantial Improvement / Damage Property Address: Company Name: Contractor Name: Contractor Address: City: State: Zip: License Number: Phone Number
Pumphouse Museum at the Historic Ottawa Beach Parks Park Township
Pumphouse Museum at the Historic Ottawa Beach Parks Park Township Project Description: Wedged between Ottawa Beach Road and the Lake Macatawa Shoreline, the historic red brick industrial building commonly
Acoustic Design Practices for Sustainable Buildings
Acoustics 2008 Geelong, Victoria, Australia 24 to 26 November 2008 Acoustics and Sustainability: How should acoustics adapt to meet future demands? Acoustic Design Practices for Sustainable Buildings Danny
March 19, 2014. Ms. Jean McDonald CAP Management 910 16th Street, Suite 1010 Denver, Colorado 80202
Ms. Jean McDonald CAP Management 910 16th Street, Suite 1010 Denver, Colorado 80202 Re: Prospector s Point Walkway/Façade Repairs Martin/Martin, Inc Project No.: 13.0358.S.02 Ms. McDonald: Per your request
Gramercy Place Condo Association, Inc.
Gramercy Place Condo Association, Inc. UNIT MODIFICATION REQUEST Date of Application: Name of Owner (s): Telephone: (Home) (Cell) E-Mail: Anticipated start date: Anticipated ending date: Permission is
WEBSTER ELEMENTARY SCHOOL New Rochelle, New York Evaluation of Collapsed Ceiling Room 204
WEBSTER ELEMENTARY SCHOOL New Rochelle, New York Evaluation of Collapsed Ceiling Room 204 Structural Inspection Report Client: CSArch Architecture Engineering Construction Management 19 Front Street, Newburgh,
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
ST. MONICA FOOD PANTRY HOUSTON, TEXAS
PROJECT MANUAL FOR ST. MONICA FOOD PANTRY HOUSTON, TEXAS OWNER: ST. MONICA CATHOLIC CHURCH 8421 W. MONTGOMERY ROAD HOUSTON, TEXAS 77088 ARCHITECT: C SIX ARCHITECTURE, LLC 4606 F.M. 1960 WEST, STE 400 HOUSTON,
Hartsfield-Jackson Atlanta International Airport s
Hartsfield-Jackson Atlanta International Airport s 2008-09 Closed Projects (Posted 1/6/2009) FC-3007000038C: MISCELLANEOUS BUILT-UP ROOF AND SINGLE PLY ROOF REPAIRS AT H-JAIA Furnish all labor, equipment,
BUILDING PERMIT APPLICATION APPLICABLE TO CITY LIMITS AND ETJ CHAPTER 18, General
BUILDING PERMIT APPLICATION APPLICABLE TO CITY LIMITS AND ETJ CHAPTER 18, General Property Address: Property Owner: Lot: Block: Subdivision: Lot Size: Scope of Work: Note: Please attach copies of all general
Building Condition Assessment: 215-219 West Lexington Street Baltimore, Maryland
KPA The Joint Venture of EBA Engineering, Inc. and Kennedy Porter & Associates, Inc. 4813 Seton Drive, Baltimore, MD 21215 Phone: (410-358-7171) Fax: (410)358-7213 Building Condition Assessment: Baltimore,
New York City Department of Buildings
The New NYC Building Code Chapter 10 Means of Egress New York City Department of Buildings Technical Affairs Fatma M. Amer, P.E. Copyright Materials This presentation is protected by US and International
Emory University Psychology Building
Emory University Psychology Building Atlanta, Georgia Chris Renshaw Submitted November 21, 2008 Executive Summary This technical assignment attempts to address the problems that have arisen during construction
Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application
February 2014 Code Requirements and Inspections in Educational Occupancies Presented By: Barry W. Rickert Douglas M. Schanne Fire Marshal Training Program Supervisor Office of Education & Data Management
Single Family Residential Basement Finish
How to Use This Guide Building Guide Pottawattamie County Planning & Development Department Building & Safety Division Single Family Residential Basement Finish Provide two (2) sets of plans and complete
TD AMERITRADE Park Omaha
TD AMERITRADE Park Omaha November 19, 2009 Report No. 6 MONTHLY CONSTRUCTION PROGRESS REPORT METROPOLITAN ENTERTAINMENT & CONVENTION AUTHORITY MONTHLY CONSTRUCTION PROGRESS REPORT Metropolitan Entertainment
