Long-Term Durability of Pressure-Treated Wood in a Severe Test Site
|
|
|
- Lesley Morris
- 10 years ago
- Views:
Transcription
1 Stan Lebow, 1 Bessie Woodward, 1 Grant Kirker, 1 and Patricia Lebow 1 Long-Term Durability of Pressure-Treated Wood in a Severe Test Site REFERENCE: Lebow, Stan, Woodward, Bessie, Kirker, Grant, and Lebow, Patricia, Long-Term Durability of Pressure-Treated Wood in a Severe Test Site, Advances in Civil Engineering Materials, Vol. 2, No. 1, 2013, pp , doi: /acem ISSN ABSTRACT: Improved estimates of the long-term durability of treated wood products are needed to guide choices about construction materials and allow estimates of design life. This report summarizes the long-term decay and insect resistance of treated wood post and lumber specimens placed in ground contact at a test site of the U.S. Department of Agriculture, Forest Service, Forest Product Laboratory in southern Mississippi. Posts treated with relatively low levels of creosote had an estimated durability of 54 years, and slightly less durability was observed in creosote-treated lumber. Pentachlorophenol-treated posts exhibited durability in excess of 60 years, whereas lumber specimens treated to standard ground-contact retentions had no failures after 39 or 45 years. Posts treated with low retentions of copper naphthenate had an estimated 65-year longevity, but lumber specimens treated to higher retentions of copper napththenate had lower average lives of 27 to 30 years. Low-retention ammoniacal copper arsenate (ACA) posts had an estimated durability of 60 years, whereas stakes treated to retentions of 8 kg/m 3 (0.5 lb/ft 3 ) or greater with ammoniacal copper zinc arsenate (ACZA) or ACA have had no failures after 30 and 60 years, respectively. Posts treated with a range of retentions of chromated copper arsenate (CCA-C) have had no failures after 35 years, and stakes treated with CCA-A, CCA-B, or CCA-C to retentions above 7 0 kg/m 3 (0.43 lb/ft 3 ) have had no failures after 60, 61, and 40 years, respectively. As a whole, the post and lumber specimens indicate an expected durability of over 50 years for creosote-treated wood and over 60 years for wood treated with pentachlorophenol, copper naphthenate, ACZA, or CCA. Comparison of the results from this site to reports from other locations suggests that these results might underestimate the potential durability in more moderate exposures. In relating these findings to treated commodities, it should be noted that these test specimens have not been subjected to the same mechanical loads or wear and tear associated with in-service structures. KEYWORDS: pressure-treated wood, long-term, durability, posts, stakes Introduction Pressure-treated wood has been widely used as a durable construction material in the United States for over a century. However, despite its long history of use, there are relatively few reports on the long-term decay and insect resistance of pressure-treated wood. Much of the data that are available are derived from replacement rate records of large users such as utilities [1 3]. In the case of utility poles, analysis of replacement rate data indicates that the average service life of poles is much greater than perceived by utility personnel. For example, Stewart [3] noted that his survey group reported an average perceived pole service life of only 33 years, whereas the replacement rate data indicated a service life in excess of 75 years. Similarly, Morrell [2] noted that based on reported replacement rates, pole service life would easily reach 80 years in many parts of the United States. Australian researchers conducted a statistical analysis of utility pole service life data and concluded that the expected service life of the poles would be in the range of 80 to 95 years [4]. A limitation of Manuscript received December 5, 2012; accepted for publication March 28, 2013; published online April 17, USDA Forest Products Laboratory, Madison, WI 53726, United States of America. 178 Copyright VC 2013 by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA
2 LEBOW ET AL. ON DURABILITY OF TREATED WOOD 179 these types of survey data is the need to differentiate replacements caused by biodeterioration from those resulting from other causes, such as severe weather events or road construction. There is also a concern that the decay category might be used as a catchall for a range of physical wood defects or discolorations. Replacement rate data are largely unavailable for most other types of commodities, including critical components such as piles or posts. Another source of long-term durability data for treated wood is field test plots established by university and government researchers. Although not truly in service, commodity-size test specimens can provide valuable insight into long-term resistance to biodeterioration. Advantages of test specimens include controlled and documented preservative treatment, known exposure conditions, and frequent inspections by personnel with expertise in evaluating biodeterioration. The most common examples are posts or lumber specimens whose durability can be related to the potential service life of terrestrial piles, poles, or posts. Treated wood piles are used as critical support members in structures such as highway and railroad bridges, whereas posts and poles are used by utilities and in building and highway construction. One of the oldest wood durability test plots was established near Corvallis, OR, by Oregon State University researchers in This site presents a moderately severe decay hazard, but it has little risk of termite attack. The majority of pressure-treated posts at this site are Douglas-fir, a species that is difficult to penetrate with preservatives. Despite these treatability challenges, groups of posts treated with creosote formulations have had no failures after either 57 or 67 years in test. Posts treated with early versions of waterborne preservative formulations have been somewhat less durable, with average times to failure ranging from 21 to 49 years [5]. Another active long-term exposure site was established near Chalk River, ON, Canada, by the Eastern Forest Products Laboratory of the Canadian Forest Service and is currently administered by FPInnovations [6]. Like the site at Oregon State University, the Ontario site has moderate decay activity but little or no termite activity. Exposure data from this site provide insight into the durability of treated wood from tree species important to Canada and the northern United States. Notably, red and white pine posts that were soaked in creosote solution had an estimated service life exceeding 70 years, and jack pine posts pressure treated with copper naphthenate in heavy solvent have had only one failure in 58 years. Similarly, red pine posts pressure treated with CCA (type A) or pentachlorophenol in heavy solvent have had no failures after 57 and 41 years, respectively [6]. The U.S. Department of Agriculture Forest Service also maintains a long-term durability test site within Harrison Experimental Forest (HEF) in Southern Mississippi. This site, established in 1937, includes ground-contact tests of both lumber (nominal 2 4) stakes and round posts treated with preservatives. The predominant wood species under evaluation is Southern Pine, which is the most commonly treated wood species grouping in the United States. Because conditions at this site present a severe biodeterioration hazard, long-term durability at this location indicates the potential for similar or greater durability at most other locations within North America. This paper summarizes the long-term durability of posts or stakes treated with preservative formulations still in commercial use and discusses the relevance of these data to the expected service life of treated commodities. Materials and Methods Site Characteristics HEF, near Saucier, MS, is a pine woodland with sandy loam soil and an average annual rainfall of 1.58 m (62 in.). The relatively high annual rainfall and warm temperatures (average annual
3 180 ADVANCES IN CIVIL ENGINEERING MATERIALS temperature of 19.6 C [67 F]) create a harsh decay environment. In addition, Eastern subterranean termites are active at the site. Copper-tolerant fungi are also present, but they are not uniformly distributed through all areas of all plots. The location is within American Wood Protection Association (AWPA) Deterioration Zone 5, Severe Hazard, which is the most severe hazard classification [7]. Post Evaluations Round Southern Pine posts with lengths of 1.8 to 2.1 m (6 to 7 ft) and top diameters of approximately 76 to 178 mm (3 to 7 in.) were air- or kiln-dried and then pressure treated with preservative [8]. Typically, a full cell treatment schedule (initial vacuum) was used for water-based treatments, and an empty cell process (ambient or initial air pressure) was used for oil-type preservatives. The number of replicate posts per treatment group varied, although groups of 25 replicates were common. The retention of preservative in the posts was determined based on weight gain following treatment and analysis of borings removed from the posts [8]. The posts were buried to a depth of approximately 0.61 m (2 ft) in a randomized block pattern with 0.91 m (3 ft) spacing between posts [8]. Periodic evaluation involved applying a force to the post, by either forcefully pushing the top of the post or applying a 22.7 kg (50 lb) load with a pull test [9]. Posts were classified as either passing (unbroken) or failing (broken). Lumber Evaluations Preparation of Stakes The stakes used for each of these treatments were Southern Pine sapwood nominal 2 4s with dimensions of 38 mm 89 mm 457 mm (1.5 in. 3.5 in. 18 in.). The stakes were pressure treated with either a full-cell (water-based preservatives) or empty-cell (oil-type preservatives) process. Typically, 10 replicate stakes were prepared for each treatment group. The retention of preservative was determined based on weight gain following treatment and the destructive analysis of extra stakes. The stakes were buried, standing upright, to a depth of 225 mm (9 in.), with the placement of stakes randomized within the plot. The stakes were periodically removed and scraped to remove soil and facilitate inspection. The stakes were then visually evaluated for decay and termite attack and were considered to have failed if greater than 75 % of the cross-section was deteriorated or they could be broken by hand. Preservative Treatments The post and lumber tests at HEF include a wide range of preservative formulations and treatment methods. The data presented in this paper are limited to posts or stakes pressure treated with preservative formulations that are similar to those in current commercial use. Coal-Tar Creosote (Creosote) Creosote is one of the oldest wood preservatives and is widely used for the treatment of piles, poles, and timbers. Creosote is a black or brownish oil made by distilling coal tar obtained after the hightemperature carbonization of coal. The character of the tar used, the method of distillation, and the temperature range in which the creosote fraction is collected all influence the composition of the creosote, and creosote s composition has varied over the years. It has also been mixed with hydrocarbon solvents or other preservatives, and some of the formulations within the HEF test site reflect
4 LEBOW ET AL. ON DURABILITY OF TREATED WOOD 181 this diversity. In this report, discussion is limited to the most commercially relevant creosote formulations without additives or additional solvents. Pentachlorophenol Pentachlorophenol has been used since the 1940s for the treatment of poles, terrestrial piles, timbers, and glued-laminated beams. Pentachlorophenol can be dissolved in either heavy (similar to #2 fuel oil) or light (similar to mineral spirits) solvents. Use of the heavy solvent is typical for ground-contact applications, and in this report discussion is limited to specimens treated with heavy solvent. Copper Naphthenate Copper naphthenate in heavy solvent has also been used to treat roundwood and timbers since the 1940s, although not as widely as creosote or pentachlorophenol. Like pentachlorophenol, copper naphthenate can be dissolved in multiple solvents, but in this report, discussion is limited to the heavy solvent typically used for ground-contact applications. Ammoniacal Copper (Zinc) Arsenate Ammoniacal copper arsenate (ACA) was used commercially, primarily on the west coast of the United States and Canada, from the 1930s to the 1980s and 1990s. It was then replaced with ammoniacal copper zinc arsenate (ACZA), which is the current commercial formulation. ACZA appears to be at least as effective as ACA, and the arsenic appears to have improved leach resistance [10,11]. This report includes data on the durability of both ACA and ACZA formulations. Chromated Copper Arsenate Types A, B, and C Chromated copper arsenate (CCA), or green-treated wood, has been widely used since the early 1940s and was the most widely used type of treated wood from the 1970s through the early 2000s. Although the use of CCA was partially restricted in 2004, CCA Type C (CCA-C) continues to be used for the treatment of poles, piles, and heavy timbers. CCA-C has a slightly different ratio of chromium:copper:arsenic than the earlier formulations (Types A and B) and became the predominate formulation because it was thought to offer the best combination of efficacy and leach resistance [12 14]. This report includes data on the durability of all three types of CCA formulations. Preservative Retention The preservative retentions (concentrations of preservative in the wood) needed to provide longterm durability have been established in the standards of the AWPA [7]. These standard retentions might vary depending on the type of preservative and the commodity being treated (Table 1). In many cases, the specimens included in this report have been treated to retentions above or below the current standard retention. Their durability is discussed here in comparison to the AWPA standard retentions. Results and Discussion Long-Term Durability in Post Tests Sets of posts treated with creosote, pentachlorophenol, copper naphthenate, or ACA were installed in 1949 and most recently rated in 2003 (Table 2). A single retention was evaluated for each preservative, and the retentions were substantially lower than specified in AWPA standards (Table 1).
5 182 ADVANCES IN CIVIL ENGINEERING MATERIALS TABLE 1 AWPA standard retentions (kg/m 3 ) for pressure-treated Southern Pine [7]. Type of Commodity and AWPA Use Category a Timbers Posts Poles Terrestrial Piles Preservative UC4A UC4B UC4C UC4A UC4B UC4A UC4B UC4C UC4C Creosote Pentachlorophenol Copper naphthenate ACZA CCA-C a Use categories designate the type of service condition. The number 4 indicates that the wood is in contact with the ground or fresh water. A indicates general use, B indicates heavy duty use, and C indicates an extreme duty application. Despite their low retentions, the posts had estimated times to failure ranging from 54 years for creosote to 74 years for pentachlorophenol. Although an increase in durability is not necessarily directly proportional to an increase in retention, the longevity of these posts would have been expected to be much greater if they had been treated to current AWPA standards. In contrast, the untreated posts failed in less than 3 years. The durability of creosote-treated posts in the HEF plots is slightly below that reported for posts exposed in South Carolina. In that location, posts treated with creosote retentions ranging from 64 to 128 kg/m 3 (4 to 8 lb/ft 3 ) had approximately 30 % failure after 50 years of exposure [15]. Much greater durability was also reported for creosote-treated posts exposed near Corvallis, OR [5], or Ontario, Canada [6]. The durability of pentachlorophenoland copper naphthenate treated posts in this study is also slightly less than that reported by Morris and Ingram [6], who noted only one failure after 58 years in copper naphthenate treated posts and no failures in pentachlorophenol-treated posts after 41 years. The greater durability reported for posts exposed near Corvallis, OR, and Ontario, Canada, might reflect the lower decay hazard in cooler northern climates. The Oregon test location falls into AWPA Hazard Zone 3 (Intermediate), whereas the more northerly Ontario site is in Hazard Zone 2 (Moderate). In contrast, the HEF location in Mississippi falls into AWPA Hazard Zone 5 (Severe) [7]. A subsequent post installation at the HEF test site in 1976 included 91 CCA-C-treated Southern Pine posts. The retentions of the posts (oxide basis) ranged from 3.52 to kg/m 3 (0.22 to 1.05 lb/ft 3 ), with the retentions of the majority of the posts in the range of 8.0 to 14.4 kg/m 3 (0.5 to 0.9 lb/ft 3 ) (Fig. 1). The condition of the posts was assessed by means of pull tests in 1984 and again TABLE 2 Estimated years to failure for Southern Pine posts in Mississippi (25 replicates per treatment group). 90% Confidence Limits Preservative Retention, kg/m 3 AWPA Pile Retention, a % Failed, % Estimated Years to Failure Lower Upper Copper naphthenate Coal-tar creosote Pentachlorophenol ACA Untreated 0 NA Note: Adapted from Refs 8 and 9. a These posts were treated to the stated percentage of AWPA standard retention [7].
6 LEBOW ET AL. ON DURABILITY OF TREATED WOOD 183 FIG. 1 Histogram of the distribution of retentions in CCA-C-treated posts. Solid bars indicate the standardized retentions for CCA-C shown in Table 1. in March of 2012 (after just over 35 years in test). None of the posts had failed, including five posts that were treated to below the AWPA specified Use Category 4A retention of 6.4 kg/m 3 (0.4 lb/ft 3 ) for CCA-C treated timbers or posts. In addition, 24 of the posts were treated to below the AWPA specified Use Category 4B retention of 9.6 kg/m 3 (0.6 lb/ft 3 ), and 66 of the posts were treated to below the AWPA specified minimum of 12.8 kg/m 3 (0.8 lb/ft 3 ) for terrestrial piles. Untreated Southern Pine post specimens fail within 2 to 4 years at this site. Long-Term Durability in Lumber (Stake) Tests The durability of lumber specimens treated to a range of creosote retentions is shown in Fig. 2. The data include values from two separate plots that have been evaluated for either 55 or 60 years. Stakes treated to above 192 kg/m 3 (12 lb/ft 3 ) have been durable, with at least 80 % remaining in test. Stakes treated to lower retentions have been less durable, with failure rates ranging from 50 % to 90 % for stakes treated to higher retentions than other AWPA standard minimum retentions. The creosote-treated lumber specimens appeared less durable than the posts, probably because of their smaller specimen volume [16]. In post specimens (and in commodity-size material in general) there is a much larger reservoir of creosote above the groundline area to replenish that which has been degraded at the wood surface. FIG. 2 Percentage of creosote-treated stakes remaining in test after 55 or 60 years of exposure. Marks on x-axis correspond to the standard retentions for creosote shown in Table 1. Each treatment group had 10 replicates.
7 184 ADVANCES IN CIVIL ENGINEERING MATERIALS FIG. 3 Percentage of pentachlorophenol-treated stakes remaining in test after 39 or 45 years of exposure. Marks on x-axis correspond to the standard retentions for pentachlorophenol shown in Table 1. Each treatment group had 9 or 10 replicates. Stakes treated with pentachlorophenol have been highly durable after 39 or 45 years of exposure (Fig. 3), with no failures in stakes treated to any of the AWPA standardized retentions. This finding extends to one treatment group that was treated to 4.6 kg/m 3 (0.29 lb/ft 3 ), which is slightly below the lowest standardized retention (4.8 kg/m 3 or 0.30 lb/ft 3 ) for pentachlorophenol-treated wood to be used in contact with the ground. Copper naphthenate treated stakes were markedly less durable than the posts, with average times to failure of 27 or 30 years for groups treated to within the range of AWPA standardized retentions (Fig. 4). The reason for the difference in durability between copper naphthenate treated posts and stakes is unclear. It might partially result from the same reservoir effect noted for creosote, but the difference between stake and post durability is much greater than that observed for creosote. Because the durability of the posts is supported by the findings of Morris and Ingram [6], it appears that the stake data might not be representative of the durability of copper naphthenate - treated wood. The copper naphthenate stake plot was established in 1941, 8 years prior to the post installation, and it is possible that the composition of the older copper naphthenate formulation was different than that of newer formulations. Naphthenic acids are usually obtained as byproducts of petroleum refining and can vary in composition and efficacy against decay fungi [17]. Although the composition of copper naphthenate is now standardized [18], it was not when either the stake or the post plot was established. Stakes treated with waterborne preservative treatments (ACA, ACZA, and CCA formulations) have had few failures when treated at or above AWPA standard retentions (Figs. 5 and 6). There FIG. 4 Average time to failure for stakes treated with copper naphthenate. Marks on x-axis indicate the standard retentions for copper naphthenate shown in Table 1. Each point is the average of 10 replicates.
8 LEBOW ET AL. ON DURABILITY OF TREATED WOOD 185 FIG. 5 Percentage of ACA- or ACZA-treated stakes remaining in test after 30, 40, or 60 years of exposure. Marks on x-axis indicate standard retentions for ACZA shown in Table 1. Each treatment group had 9 or 10 replicates. have been no failures in stakes treated with ACA to retentions of 8.0 kg/m 3 (0.5 lb/ft 3 ) after 60 years, and no failures in stakes treated with ACZA to retentions of 4.0 kg/m 3 (0.25 lb/ft 3 ) after 30 years. Stakes treated to 7.2 kg/m 3 (0.45 lb/ft 3 ) with ACA have had 20 % and 10 % failures after 40 and 60 years, respectively. Stakes treated with the CCA formulations also appear highly durable (Fig. 6). The CCA-C- and CCA-B-treated stakes have had no failures after 40 and 61 years, respectively, with retentions at or above the lowest AWPA standardized retention for wood in contact with the ground. The CCA-A formulation appears to be only slightly less effective, with 20 % failures in stakes treated to 7.0 kg/m 3 (0.43 lb/ft 3 ) after 60 years in test. As a whole, the post and lumber specimen exposure data indicate that for general-use ground contact retentions, the expected durability of creosote-treated wood will be in excess of 50 years, and that of wood treated with pentachlorophenol, ACZA, or CCA will be 60 years or more. It is notable that specimens treated with pentachlorophenol, ACZA, or CCA appear to be at least as durable as those treated with creosote. Creosote has a long history of commercial use, and some users are reluctant to use other preservatives because of concerns that they might not be as effective as creosote [19]. The copper naphthenate data are more difficult to interpret because of the conflict between the high durability of the post specimens and the more moderate durability of the lumber specimens. If one assumed that the formulation used to treat the lumber specimens was substandard, the durability of copper naphthenate treated wood would also be expected to exceed 60 years. Higher FIG. 6 Percentage of CCA-treated stakes remaining in test after 40, 60, or 61 years of exposure. Marks on x-axis indicate standard retentions for CCA-C shown in Table 1. Each treatment group had 8 to 10 replicates.
9 186 ADVANCES IN CIVIL ENGINEERING MATERIALS retentions, such as those standardized for Use Category 4C, would be expected to result in greater durability. Wood treated with the oil-type preservatives would also be expected to have greater durability when used in larger-size commercial commodities such as poles, piles, and timbers. There are important differences between the durability of stake and post specimens and the expected service life of treated commodities. The specimens were treated under controlled laboratory conditions and thus probably do not reflect the range of treatment qualities that might be encountered in commercial practice. The specimens are also not subjected to the post-treatment cutting or drilling that can expose untreated wood in commercial structures. Untreated wood exposed during construction should be field-treated with preservative or physically protected (with pile caps, for example), or both, but these practices are not always followed. In this respect, the lumber and post specimens reflect the potential durability of wood products that meet the standards of treatment quality and are properly protected during construction. It is also notable that the test specimens are not subjected to the same types of mechanical loads and stresses that might be expected for treated wood in service. The post specimens were subjected to a pull test during inspection, but the evaluation of the lumber specimens was largely visual. Some types of decay fungi can cause substantial strength loss before the damage is readily apparent on the exterior of the wood. The HEF exposure site also represents only one set of conditions, although it is expected that these exposure conditions are at least as severe as those of most other locations within the United States. The lesser durability for creosote-, pentachlorophenol-, and copper naphthenate - treated specimens at the HEF site relative to exposure sites in Oregon [5] or Canada [6] might partially reflect the severity of the exposure. Conclusions Long-term post and lumber durability tests provide insight into the expected durability of wood products that have been treated to AWPA standards and properly handled during construction. This review of the durability data from a test site in southern Mississippi indicates that the expected durability of creosote-treated wood is in excess of 50 years, and that of wood treated with pentachlorophenol, ACZA, or CCA exceeds 60 years. No failures have occurred in lumber specimens treated to intermediate or high retentions of pentachlorophenol, ACZA, or CCA formulations. The expected durability of specimens treated with copper naphthenate was more difficult to interpret because of conflicting results between tests with lumber and post specimens. However, the post specimens indicated durability in excess of 60 years, even at retentions substantially below those currently used commercially. Some caution is needed in extrapolating the durability observed in these test specimens to in-service structures, as the specimens are not subjected to the same mechanical loads or potential damage during construction. Conversely, comparison of the results from this site to reports from other locations suggests that these results might underestimate potential durability in more northern climates. References [1] Subcommittee T-4, Poles, Appendix A: Pole Service Life Data Report of Subcommittee T-4, Poles, Proceedings of the 90th Annual Meeting of the American Wood-Preservers Association, San Antonio, TX, May 14 18, American Wood Protection Association, Birmingham, AL, 1994, pp
10 LEBOW ET AL. ON DURABILITY OF TREATED WOOD 187 [2] Morrell, J. J., 2008, Estimated Service Life of Wood Poles, Technical Bulletin, North American Wood Pole Council, (Last accessed 5 April 2013). [3] Stewart, A. H., 1996, Wood Pole Life Span: What You Can Expect, Wood Pole Newsletter, Vol. 20, (Last accessed 5 April 2013). [4] Mackisack, M. S. and Stillman, R. H., A Cautionary Tale about Weibull Analysis, IEEE Trans. Reliab., Vol. 45(2), 1996, pp [5] Morrell, J. J., Miller, D. J., and Schneider, P. F., Service Life of Treated and Untreated Fences Posts: 1996 Post Farm Report, Research Contribution 26, Forest Research Laboratory, Oregon State University, Corvallis, Oregon, [6] Morris, P. I. and Ingram, J. K., 2010, Field Testing of Wood Preservatives XIX: Industrial Preservatives, Proceedings of the Annual Meeting of the Canadian Wood Preservation Association, Vancouver, BC, October 19 20, 2010, Canadian Wood Preservation Association, Vancouver, BC. [7] AWPA Standard U1, 2012, Use Category System: User Specification for Treated Wood, Book of Standards, American Wood Protection Association, Birmingham, AL. [8] Davidson, H. L., Comparison of Wood Preservatives in Mississippi Post Study (1977 Progress Report), Research Note FPL RN 01, U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, Madison, WI, [9] Freeman, M. H., Crawford, D. M., Lebow, P. K., and Brient, J. A., A Comparison of Wood Preservatives in Posts in Southern Mississippi: Results from a Half-Decade of Testing, Proceedings of the 101st Annual Meeting of the American Wood-Preservers Association, New Orleans, LA, May 15 17, 2005, American Wood Protection Association, Birmingham, AL, pp [10] Best, C. W. and Coleman, C. C., 1982, AWPA Standard M11: An Example of Its Use, Proceedings of the 77th Annual Meeting of the American Wood-Preservers Association, Kissimmee, FL, April 26 29, 1981, American Wood Protection Association, Birmingham, AL, pp [11] Lebow, S. T., Leaching of Wood Preservative Components and Their Mobility in the Environment Summary of Pertinent Literature, General Technical Report FPL-GTR-93, USDA, Forest Service, Forest Products Laboratory, Madison, WI, [12] Fahlstrom, G. B., Copper-chrome-arsenate Wood Preservatives: A Study of the Influence of Composition on Service Performance, Proceedings of the 74th Annual Meeting of the American Wood-Preservers Association, Washington, D.C., April 24 26, 1978, American Wood Protection Association, Birmingham, AL, pp [13] Fahlstrom, G. B., Gunning, P. E., and Carlson, J. A., Copper-chrome-arsenate Wood Preservatives: A Study of the Influence of Composition on Leachability, Forest Prod. J., Vol. 17(7), 1967, pp [14] Hartford, W. H., Fahlstrom, G. B., and Colley, R. H., The Effect of Composition on the Effectiveness of CCA Preservatives. II. Update from 1978 and Application of Both Performance Index and Log-probability Statistics to Recent Data, Proceedings of the 78th Annual Meeting of the American Wood-Preservers Association, New Orleans, LA, May 2 5, 1982, American Wood Protection Association, Birmingham, AL, pp [15] Webb, D., Fox, R., and Pfeiffer, R., Creosote Posts Final Inspection of the 1958 Cooperative Test after 50 Years of Exposure as a Ground Contact Preservative, Proceedings of the 105th
11 188 ADVANCES IN CIVIL ENGINEERING MATERIALS Annual Meeting of the American Wood Protection Association, San Antonio, TX, April 19 21, 2009, American Wood Protection Association, Birmingham, AL, pp [16] Woodward, B. M., Hatfield, C. A., and Lebow, S. T., Comparison of Wood Preservatives in Stake Tests: 2011 Progress Report, Research Note FPL RN 02, U.S. Department of Agriculture, Forest Service, Forest Products Laboratory, Madison, WI, [17] Niemi, B., St. John, W., Woodward, B., DeGroot, R., and McGinnis, G., Development of Naphthenic Acid Fractionation With Supercritical Fluid Extraction for Use in Wood Decay Testing, Proceedings of the 94th Annual Meeting of the American Wood-Preservers Association, Scottsdale, AZ, May 17 19, 1998, American Wood Protection Association, Birmingham, AL, pp [18] AWPA P36-11, 2012, Standard for Copper Naphthenate (CuN), Book of Standards, American Wood Protection Association, Birmingham, AL. [19] Lebow, S. and Wacker, J., Common Questions and Concerns from Government Users of Industrial Treated Wood Products, Proceedings of the 107th Annual Meeting of the American Wood Protection Association, Fort Lauderdale, FL, May 15 17, 2011, American Wood Protection Association, Birmingham, AL.
CHAPTER 3.0 TIMBER PILE PROPERTIES
CHAPTER 3.0 TIMBER PILE PROPERTIES 3.1 INTRODUCTION The design of timber pile foundations requires a firm understanding of the mechanical properties of the timber pile. There are generally two species
Specifying Treated Wood Paul I Morris, Group Leader Durability and Protection
www.fpinnovations.ca Specifying Treated Wood Paul I Morris, Group Leader Durability and Protection Presentation Outline Treated wood in the 2010 NBCC and other uses Overview of CSA O80 Series: Wood Preservation
Specification. Guide for. Wolmanized. Pressure-Treated. Wood
Specification Guide for Wolmanized Pressure-Treated Wood 2 Wolmanized Pressure-Treated Wood Wolmanized wood is poles, piles, timbers, posts, or plywood that is pressure-treated with CCA preservative to
Durability of Wood Bridges
Durability of Wood Bridges Paul Morris Research Leader, Wood Protection Group, FPInnovations Page 1 of 9 Durability of Wood Bridges Paul Morris Research Leader, Wood Protection Group, FPInnovations Timber
Treating Treated Wood Decks. Terry L. Amburgey and Kevin W. Ragon
Treating Treated Wood Decks Terry L. Amburgey and Kevin W. Ragon Abstract The majority of the residential and non-residential decks in the US are fabricated using wood that has been pressure-treated with
Types of Wood Preservatives
Copper Naphthenate Copper naphthenate is effective when used in ground contact, water contact, or aboveground. It is not standardized for use in saltwater applications. Copper naphthenate s effectiveness
INDUSTRIAL TREATED WOOD USERS GUIDANCE DOCUMENT
INDUSTRIAL TREATED WOOD USERS GUIDANCE DOCUMENT Guidance for the Industrial Treated Wood User Concepts to include in an Environmental Management System concerning the use of Wood treated with CCA (chromated
Chapter 18. Round Timbers and Ties. Contents. Standards and Specifications. Material Requirements. Ronald W. Wolfe
Round Timbers and Ties Ronald W. Wolfe Chapter 18 Contents Standards and Specifications 18 1 Material Requirements 18 1 Availability 18 2 Poles 18 2 Piles 18 3 Construction Logs 18 3 Ties 18 3 Form 18
Nordic requirements for quality control of preservativetreated
Nordic requirements for quality control of preservativetreated wood Part 1: Pine and other permeable softwoods NWPC Document No 3:2013 Nordic Wood Preservation Council 2012 2 NWPC Document No 3:2013 Nordic
SECTION 02845 GUARDRAILS
SECTION 02845 GUARDRAILS PART 1 - GENERAL 1.01 SCOPE OF WORK A. Furnish all labor, materials, equipment and incidentals necessary and repair, replace or install all types of guardrails as specified herein
Robert H. White, Research Wood Scientist, U.S. Forest Products Lab., Madison, WI, USA, [email protected] Brian Kukay, Associate Professor of General
Robert H. White, Research Wood Scientist, U.S. Forest Products Lab., Madison, WI, USA, [email protected] Brian Kukay, Associate Professor of General Engineering, Montana Tech of the University of Montana,
Enhanced Wood Performance with Environmental Responsibility
Enhanced Wood Performance with Environmental Responsibility 06 05 73/VIA BuyLine 7308 Mold Resistant Wood Stabilized Weather Resistant Wood Fire-Retardant Treated Wood Decay & Termite Resistant Wood Decay
A3052 PROTECTING WOOD FENCES FOR YARD AND GARDEN
A3052 PROTECTING WOOD FENCES FOR YARD AND GARDEN Rodney C. De Groot, William C. Feist, Wallace E. Eslyn, Lee R. Gjovik Centuries-old fences still stand in eastern United States, but the native chestnut
Preservative Treatments of Fence Posts
0 C)EGO STA1ifi REGON I II II Preservative Treatments of Fence Posts 1940 Progress Report on the Post Farm By T. J. STARKER Bulletin Series, No. 9B November 1940 (supplement B to Bulletin No. 9, issued
Pressure-Treated Southern Pine
Pressure-Treated Southern Pine standards specifications applications The Southern Forest Products Association (SFPA) is a nonprofit trade promotional group supported by Southern Pine lumber manufacturers.
Efficacy of Alternative Preservatives Used in Dip Treatments for Wood Boxes
United States Department of Agriculture Forest Service Forest Products Laboratory Research Paper FPL-RP-48 Efficacy of Alternative s Used in Dip Treatments for Wood Boxes Rodney C. DeGroot Michael Stroukoff
An International Termite Field Test of Wood Treated with Insecticides in a Buffered Amine Oxide Carrier
An International Termite Field Test of Wood Treated with Insecticides in a Buffered Amine Oxide Carrier Paul Ian Morris J. Kenneth Grace Tsuyoshi Yoshimura Kunio Tsunoda Abstract A buffered amine oxide
There s a new problem on deck. Corrosion. And now there s a solution. Quick and easy. G VYCOR DECK PROTECTOR. Self-Adhered Flashing
There s a new problem on deck. Corrosion. And now there s a solution. Quick and easy. G VYCOR DECK PROTECTOR Self-Adhered Flashing G Good news for the environment is bad news for decks. New wood preservatives
Condition Assessment of a Historic Trout Rearing Station in Upper Michigan
United States Department of Agriculture Condition Assessment of a Historic Trout Rearing Station in Upper Michigan Frederico J. N. França Tâmara S. F. Amorim França Lon A. Yeary Christopher Hohnholt John
Oil Analysis. It is important that the sampling be done in the following manner: 1.
Oil Analysis Introduction Oil analysis was originally used by the military and the railroad as a preventative maintenance program. It has expanded today to the fi eld of study called Tribology. Oil analysis
General Approach. Structure Components. Is all lumber the same? Lumber Grades. Rafters Girders / Beams Columns. Sketch general structural layout
General Approach Sketch general structural layout Determine roof loading Determine required lumber dimensions Transfer load down the structure Structure Components Plants Structure Components Top Side
Tried, Tested and Proven Timber Protection
November 05 A Choice of Treatments SPECIFIER S GUIDE Tried, Tested and Proven Timber Protection Preservative and fire retardant industrial treatments to help make the most of timber. Tried, Tested and
The AASHO Road Test site (which eventually became part of I-80) at Ottawa, Illinois, was typical of northern climates (see Table 1).
Página 1 de 12 AASHO Road Test The AASHO Road Test, a $27 million (1960 dollars) investment and the largest road experiment of its time, was conceived and sponsored by the American Association of State
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
Conclusions and Summary Report Environmental Life Cycle Assessment of Highway Guard Rail Posts
Conclusions and Summary Report Environmental Life Cycle Assessment of Highway Guard Rail Posts ISO 14044 Compliant Prepared by: AquAeTer, Inc. Treated Wood Council (2013) Conclusions and Summary Report
TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For:
TEST REPORT Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PRODUCT: Gorilla Column PVC Porch Post System with PVC Base / Cap Plates, PVC Bushings and 2-3/8 in Diameter and 3-1/2 in Diameter Galvanized
SECTION 02200 SUPPORT OF EXCAVATION
SECTION 02200 PART 1 GENERAL 1.01 DESCRIPTION A. Section including specifications for design and installation of excavation support. B. Section also includes specifications for excavation support systems
TEST REPORT. Rendered to: DEXERDRY. For: Deck Weatherproofing System Installed with AZEK Deck Boards
TEST REPORT Rendered to: DEXERDRY For: Deck Weatherproofing System Installed with AZEK Deck Boards Report No.: E8122.01-119-19 Revision 1: 08/18/15 Report Date: 08/14/15 Test Record Retention Date: 07/16/19
EVALUATION OF THE PERFORMANCE OF THE PROTECTIVE SURFACE COATINGS FOR CONCRETE
EVALUATION OF THE PERFORMANCE OF THE PROTECTIVE SFE COATINGS FOR CONCRETE Haimoon CHEONG * Hwangu YU *2 Taesong AHN *3 Byunghwan OH *4 ABSTRT: Chloride penetration into concrete is the main cause of the
Fungal Damage in Buildings with Emphasis on Meruliporia poria incrassata
Fungal Damage in Buildings with Emphasis on Meruliporia poria incrassata prepared by Stephen L. Quarles, Ph.D. University of California Cooperative Extension Advisor Emeritus Many species of fungi can
A STUDY OF TERMITES DESTROYING STRUCTURAL WOOD IN HYDERABAD URBAN SYSTEM
A STUDY OF TERMITES DESTROYING STRUCTURAL WOOD IN HYDERABAD URBAN SYSTEM Dr.S.Venkata Rama Raju, M.Sc;M.Ed; M.Phill;Ph.D(in Zoology) H.No. 15-142/1/G7,Sahithi Nest Apartment,P&T colony,dilsukhnagar, Hyderabad
STEAM AND ELECTRICAL CONSUMPTION IN A COMMERCIAL SCALE LUMBER DRY KILN
STEAM AND ELECTRICAL CONSUMPTION IN A COMMERCIAL SCALE LUMBER DRY KILN Tom Breiner and Stephen L. Quarles Forest Products Laboratory University of California Richmond, California Dean Huber U.S. Forest
FEDERAL SPECIFICATION BEADS (GLASS SPHERES) RETRO-REFLECTIVE
INCH-POUND TT-B-1325D 10 July 2007 SUPERSEDING TT-B-1325C June 1, 1993 FEDERAL SPECIFICATION BEADS (GLASS SPHERES) RETRO-REFLECTIVE The General Services Administration has authorized the use of this federal
Owner s Guide to Understanding Checks in Glued Laminated Timber
Owner s Guide to Understanding Checks in Glued Laminated Timber ENGINEERED WOOD SYSTEMS Checking In Glued Laminated Timber Glued laminated timber (glulam) is an engineered wood product that is used in
EVALUATION ACCORDING TO ASTM F
Bodycote Report EVALUATION ACCORDING TO ASTM F 2023 Evaluation of the chlorine resistance according to ASTM F 2023 of the PB pipe material PB4267 GREY Mattias Svedberg RESTRICTED DISTRIBUTION SE-611 82
PRESTRESSED CONCRETE POLES The Solid Alternative to Wood
Prestressed Concrete Utility Poles U-1 PRESTRESSED CONCRETE S The Solid Alternative to Wood Lonestar Prestress concrete poles were developed to meet the expanding need of a supporting structure for; street,
Series 4000 Fiberglass Pipe and Fittings
Series 4000 Fiberglass Pipe and Fittings for corrosive industrial service Uses and applications Listings Performance Acid drains Chemical process piping Corrosive slurries Food processing Geothermal Nonoxidizing
Factors that influence the speed of bacterial wood degradation
Factors that influence the speed of bacterial wood degradation René K.W.M. Klaassen SHR Timber Research, PO box 497 NL-6700 AL Wageningen The Netherlands [email protected] Abstract Bacterial wood decay
NATURAL DURABILITY OF DIFFERENT WOOD SPECIES RESULTS AFTER FIVE YEARS TESTING IN GROUND CONTACT
NATURAL DURABILITY OF DIFFERENT WOOD SPECIES RESULTS AFTER FIVE YEARS TESTING IN GROUND CONTACT Flæte, P.O. 1, Evans, F.G. 2 & Alfredsen, G. 3 ABSTRACT Information given in EN 350-2 on natural durability
Evaluation and Field Load Testing of Timber Railroad Bridge
Transportation Research Record 1696 Paper No. 5B0112 323 Evaluation and Field Load Testing of Timber Railroad Bridge Terry J. Wipf, Michael A. Ritter, and Douglas L. Wood Several spans of a 60-year-old
Fire Testing of Recycled Materials for Building Applications
Fire Testing of Recycled Materials for Building Applications Robert H. White Abstract To gain wide market acceptance of new building products made from recycled materials, fire testing may be necessary.
G VYCOR DECK PROTECTOR. For longer lasting decks, install Grace Vycor Deck Protector. It s an easy add-on to your deck projects.
For longer lasting decks, install Grace Vycor Deck Protector. It s an easy add-on to your deck projects. G VYCOR DECK PROTECTOR Self-Adhered Flashing NEW FROM THE MAKERS OF G Ice & Water Shield I Moisture
10DBMC International Conference On Durability of Building Materials and Components LYON [France] 17 20 April 2005
10DBMC International Conference On Durability of Building Materials and Components Wall Cladding System Durability Lessons Learned from the Premature Deterioration of Wood-Framed Construction Clad with
Scholars Research Library
Available online at www.scholarsresearchlibrary.com Scholars Research Library Archives of Physics Research, 2010, 1 (2):103-111 (http://scholarsresearchlibrary.com/archive.html) ISSN 0976-0970 Lubricating
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries
Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries Introduction Wastewater of petrochemical industries and refineries contains high amounts of emulsified aliphatic or
Biodiesel Research Project Final Report Summary
Biodiesel Research Project Final Report Summary Funded by Imperial Oil, Canadian Petroleum Products Institute and Natural Resources Canada under National Renewable Diesel Demonstration Initiative (NRDDI)
Timber Decks. Technical Note. March 2007
Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.
SPECIFIC INSTRUCTIONS ON HOW TO PERIODICALLY CHECK FOR STRESS CRACKING CAUSED BY CHEMICALS, HANDLING ABUSE & ENVIRONMENTAL DEGRADATION
SPECIFIC INSTRUCTIONS ON HOW TO PERIODICALLY CHECK FOR STRESS CRACKING CAUSED BY CHEMICALS, HANDLING ABUSE & ENVIRONMENTAL DEGRADATION Provides the same capability for checking your liquid bulk storage
PVC PIPE PERFORMANCE FACTORS
PVC PIPE PERFORMANCE FACTORS PVC pipe, like all flexible pipe products, is very dependent on the surrounding soil for its structural capacity, in addition, the pipe material must have sufficient inherent
Residential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer 1
Designation: D562 01 (Reapproved 2005) Standard Test Method for Consistency of Paints Measuring Krebs Unit () Viscosity Using a Stormer-Type Viscometer 1 This standard is issued under the fixed designation
COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET
[METRIC] A-A-59135 28 OCTOBER 1997 SUPERSEDING PPP-C-1752D(3) 1 FEBRUARY 1993 COMMERCIAL ITEM DESCRIPTION PACKAGING MATERIAL, SHEET The General Services Administration has authorized the use of this commercial
Analysis of the Interstate 10 Twin Bridge s Collapse During Hurricane Katrina
Analysis of the Interstate 0 Twin Bridge s Collapse During Hurricane Katrina By Genda Chen, Emitt C. Witt III, David Hoffman, Ronaldo Luna, and Adam Sevi The Interstate 0 Twin Span Bridge over Lake Pontchartrain
ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT. Rendered to: BEKAERT SPECIALTY FILMS, LLC
ASTM E 1886 / ASTM E 1996 AND ASTM E 283, ASTM E 330, ASTM E 331 TEST REPORT Rendered to: BEKAERT SPECIALTY FILMS, LLC SERIES/MODEL: Panorama 8-mil Film PRODUCT TYPE: Fixed Window with Applied Film This
Fire, Forest History, and Ecological Restoration of Ponderosa Pine Forests at Mount Rushmore, South Dakota
Fire, Forest History, and Ecological Restoration of Ponderosa Pine Forests at Mount Rushmore, South Dakota Restoration uses the past not as a goal but as a reference point for the future...it is not to
Frost Damage of Roof Tiles in Relatively Warm Areas in Japan
Frost Damage of Roof Tiles in Relatively Warm Areas in Japan Influence of Surface Finish on Water Penetration Chiemi IBA Hokkaido Research Organization, Japan Shuichi HOKOI Kyoto University, Japan INTRODUCTION
INFORMATION SHEET ON TERMITES & TERMITE MANAGEMENT PROCEDURES
INFORMATION SHEET ON TERMITES & TERMITE MANAGEMENT PROCEDURES IMPORTANT INFORMATION: The Australian Standard AS 3660.2 Protection of buildings from subterranean termites provides details for minimising
Wildfire Damage Assessment for the 2011 Southeast Complex Fires
Wildfire Damage Assessment for the 2011 Southeast Complex Fires Chip Bates & Mark McClure, Forest Health Management Background: On March 24, 2011, multiple wildfires began across southeast Georgia. Strong,
Bioremediation. Introduction
Bioremediation Introduction In the twentieth century, the ever increase in the global human population and industrialization led to the exploitation of natural resources. The increased usage of heavy metals
Nondestructive Testing and Evaluation of Steel Bridges
Abstract Nondestructive Testing and Evaluation of Steel Bridges James Bader ENCE 710 Spring 2008 Nondestructive evaluation (NDE) is a means of evaluating structural components without damaging them. It
Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete
Fire-Damage or Freeze-Thaw of Strengthening Concrete Using Ultra High Performance Concrete Ming-Gin Lee 1,a, Yi-Shuo Huang 1,b 1 Department of Construction Engineering, Chaoyang University of Technology,Taichung
TECHNICAL RECOMMENDATION
TECHNICAL RECOMMENDATION NO: 9 DESIGN OF LIGHT TIMBER FRAMED WALLS AND FLOORS FOR FIRE RESISTANCE Peter Collier Contents Design of Light Timber Framed Walls and Floors for Fire Resistance Relevance Acceptance
A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil
ISSN: 319-53 (An ISO 39: 00 Certified Organization) A study on the Effect of Distorted Sampler Shoe on Standard Penetration Test Result in Cohesionless soil Utpal Kumar Das Associate Professor, Department
ATI Evaluation Service A Division of Architectural Testing Certification Services
ATI Evaluation Service A Division of Architectural Testing Certification Services Subject to Renewal: 09/01/2016 Issued: 09/04/2015 Visit www.ati-es.com for current status Page 1 of 17 UFP Ventures II,
Creep Behavior of Structural Insulated Panels (SIPs)
Creep Behavior of Structural Insulated Panels (SIPs) Results from a Pilot Study Dwight McDonald Marshall Begel C. Adam Senalik Robert J. Ross Thomas D. Skaggs Borjen Yeh Thomas Williamson United States
TEST REPORT. Rendered to: LMT-Mercer Group, Inc. For: PRODUCT: 4" x 4" and 5" x 5" PVC Porch Posts with Aluminum Reinforcing
TEST REPORT Rendered to: LMT-Mercer Group, Inc. For: PRODUCT: 4" x 4" and 5" x 5" PVC Porch Posts with Aluminum Reinforcing Report No.: Report Date: 01/28/14 Test Record Retention Date: 12/20/17 130 Derry
THE SELECTION OF BRIDGE MATERIALS UTILIZING THE ANALYTICAL HIERARCHY PROCESS
THE SELECTION OF BRIDGE MATERIALS UTILIZING THE ANALYTICAL HIERARCHY PROCESS Robert L. Smith Assistant Professor/Extension Specialist, Virginia Tech Robert J. Bush Associate Professor, Virginia Tech and
Revealing the costs of air pollution from industrial facilities in Europe a summary for policymakers
Revealing the costs of air pollution from industrial facilities in Europe a summary for policymakers A new European Environment Agency (EEA report, Revealing the costs of air pollution from industrial
Compliant Terminal Technology Summary Test Report
Engineering Report ER04100 October 5th, 2004 Revision A Copyright Autosplice Inc., September 2004 Table of Contents Summary Overview 3 Compliant Terminal Specifications 3 Test Plan 4 Test Conditions 4
GUARDRAIL INNOVATION FLOWS FROM HERE
INNOVATION FLOWS FROM HERE ENSURING SAFETY ON CANADIAN HIGHWAYS The economics, versatility, and performance of Guardrail surpass all other roadside barrier systems. Guardrail provides highly-visible protection
Proceedings 2005 Rapid Excavation & Tunneling Conference, Seattle
Proceedings 2005 Rapid Excavation & Tunneling Conference, Seattle EPB-TBM Face Support Control in the Metro do Porto Project, Portugal S. Babendererde, Babendererde Engineers LLC, Kent, WA; E. Hoek, Vancouver,
BORA-CARE. Effective Wood Treatment.
BORA-CARE Effective Wood Treatment. Builders are saving one full day of cycle time with Bora-Care termite pretreatments. Bora-Care eliminates the need to coordinate schedules with the pest control and
Chapter 22: Overview of Ecological Risk Assessment
Chapter 22: Overview of Ecological Risk Assessment Ecological risk assessment is the process of gaining an understanding of the likelihood of adverse effects on ecological receptors occurring as a result
Product Guide. FrameGuard Total Wood
Product Guide FrameGuard Total Wood Protection from the Ground Up FrameGuard Total mold-resistant wood provides protection against mold, termites, and fungal decay in trusses, framing, OSB, SIPs, and other
Evaluating the Condition of Seawalls/Bulkheads
Volume 2 Evaluating the Condition of Seawalls/Bulkheads By: Coastal Systems International, Inc. Typical bulkhead under construction Seawalls and bulkheads (walls) provide shoreline stabilization for many
CATHODIC PROTECTION SYSTEM DESIGN
CATHODIC PROTECTION SYSTEM DESIGN Presented By DENIS L ROSSI P.E. CORROSION ENGINEER New England C P Inc. Corrosion Fundamentals What is corrosion? It is defined as the degradation or deterioration of
DuPont Altriset Termiticide Technical Bulletin
DuPont Altriset Termiticide Technical Bulletin utstanding Performance ow there is a non-repellent termiticide that provides excellent control of termites yet has minimal impact on the environment. The
The entire document shall be read and understood before proceeding with a test. ISTA 3B 2013 - Page 1 of 35
Packaged-Products for Less-Than-Truckload (LTL) Shipment ISTA 3 Series General Simulation Performance Test PROCEDURE VERSION DATE Last TECHNICAL Change: NOVEMBER 2012 Last EDITORIAL Change: JANUARY 2013
N O T E S. Environmental Forensics. Identification of Natural Gas Sources using Geochemical Forensic Tools. Dispute Scenarios
Environmental Forensics N O T E S V o l u m e 2 9 Identification of Natural Gas Sources using Geochemical Forensic Tools By Paul Boehm, Ph.D. and Tarek Saba, Ph.D. F o r m o r e i n f o r m a t i o n o
Specific Gravity, Moisture Content, and Density Relationship for Wood
United States Department of Agriculture Forest Service Forest Products Laboratory General Technical Report FPL-GTR-76 Specific Gravity, Moisture Content, and Density Relationship for Wood William T. Simpson
Integration of a fin experiment into the undergraduate heat transfer laboratory
Integration of a fin experiment into the undergraduate heat transfer laboratory H. I. Abu-Mulaweh Mechanical Engineering Department, Purdue University at Fort Wayne, Fort Wayne, IN 46805, USA E-mail: [email protected]
Weathering, Erosion, and Soils. Weathering and Erosion. Weathering and Erosion
Weathering, Erosion, and Soils 1 The Grand Canyon, a landscape shaped by weathering and erosion 2 Weathering vs. erosion Types of weathering Physical Chemical Rates of weathering and erosion Climate Rock
INTERPRETATION ADDENDUM CANADIAN MINING COMPANY INC. SUITE 2300-1066 WEST HASTINGS STREET VANCOUVER, BC V6E 3X2 3D INDUCED POLARIZATION
INTERPRETATION ADDENDUM FOR CANADIAN MINING COMPANY INC. SUITE 2300-1066 WEST HASTINGS STREET VANCOUVER, BC V6E 3X2 3D INDUCED POLARIZATION ON THE SAN BERNARDO PROJECT EL GOCHICO GRID Approximate Location:
YEAR TRANSFERRABLE TANALISED 25 YEAR TERMITE RESISTANT* STRUCTURAL TIMBER AND WOOD PRODUCTS GUARANTEE
TRANSFERRABLE TANALISED 25 TERMITE RESISTANT* STRUCTURAL TIMBER AND WOOD PRODUCTS GUARANTEE Thank you for selecting Tanalised termite resistant* structural timber and wood products for your new home or
research highlight Water Penetration Resistance of Windows - Study of Codes, Standards,Testing, and Certification
research highlight November 2003 Technical Series 03-125 Water Penetration Resistance of Windows - Study of Codes, Standards,Testing, and Certification introduction Over the past decade, there has been
Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008. Foundation Heave Protection
Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February 2008 Foundation Heave Protection The safe, sure way to provide foundation protection Clayshield is the proven solution to protecting foundations against
FINAL FAILURE INVESTIGATION WESTCHESTER NORTH LAGOON BRIDGE. Anchorage, Alaska
FINAL FAILURE INVESTIGATION WESTCHESTER NORTH LAGOON BRIDGE Anchorage, Alaska August 2014 Prepared for: Municipality of Anchorage Project Management and Engineering P.O. Box 196650 Anchorage, Alaska 99519-6650
Surveying Historic Timber Framed Buildings
Surveying Historic Timber Framed Buildings The survey, identification of defects and specification of remedial work in timber framed buildings is a specialised area and a trap for the unwary. Richard Oxley
Commonwealth of Pennsylvania PA Test Method No. 632 Department of Transportation October 2013 5 Pages LABORATORY TESTING SECTION. Method of Test for
Commonwealth of Pennsylvania PA Test Method No. 632 Department of Transportation 5 Pages LABORATORY TESTING SECTION Method of Test for TIME OF SETTING OF CONCRETE MIXTURES BY PENETRATION RESISTANCE 1.
Elastomer Compatibility Testing of Renewable Diesel Fuels
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Elastomer Compatibility Testing
