Step Change in Well Testing Operations
|
|
|
- Lindsey Florence Turner
- 10 years ago
- Views:
Transcription
1 Step Change in Well Testing Operations In exploration and appraisal environments, one way to gather data for well productivity and reservoir characterization is through well or drillstem testing. The acquisition of downhole well test data has recently been enhanced by the development of an acoustic wireless telemetry system that gives operators access to these data in real time. Amine nnaifer Palma Giordano Stephane Vannuffelen Clamart, France Bengt Arne Nilssen Houston, Texas, USA Ifeanyi Nwagbogu Lagos, Nigeria Andy Sooklal Carl Walden Maersk Oil Angola AS Luanda, Angola Oilfield eview Autumn 2014: 26, no. 3. Copyright 2014 Schlumberger. For help in preparation of this article, thanks to Michelle Parker Fitzpatrick, Houston; and David Harrison, Luanda, Angola. CTIS, CQG, InterACT, IDV, Muzic, Quartet, T Certain, SCA, Signature and StethoScope are marks of Schlumberger. 1. Skin is a term used in reservoir engineering theory to describe the restriction of fluid flow from a geologic formation to a well. Positive skin values quantify flow restriction, whereas negative skin values quantify flow enhancements, typically created by artificial stimulation operations such as acidizing and hydraulic fracturing. 2. Al-Nahdi AH, Gill HS, Kumar V, Sid I, Karunakaran P and Azem W: Innovative Positioning of Downhole Pressure Gauges Close to Perforations in HPHT Slim Well During a Drillstem Test, paper OTC 25207, presented at the Offshore Technology Conference, Houston, May 5 8, Kuchuk FJ, Onur M and Hollaender F: Pressure Transient Formation and Well Testing: Convolution, Deconvolution and Nonlinear stimation. Amsterdam: lsevier, Developments in Petroleum Science 57, By the time dgar and Mordica Johnston performed the first commercial drillstem test in 1926, more than two dozen formation tester patents had been issued. Before the Johnston brothers introduced their innovative methods, if oil did not flow to the surface, exploration wells were tested through bailing lowering a hollow tube on a cable to capture a formation fluid sample after casing had been set and cemented above the zone of interest. The brothers success led to the creation of the Johnston Formation Testing Company, which Schlumberger acquired in Today, the most common drillstem tests (DSTs) are temporary well completions through which operators produce formation fluids while the drilling unit is on location. During DSTs, formation fluids are typically produced through drillpipe or tubing to a test separator or other temporary surface processing facility, where the fluids are metered, sampled and analyzed. Drillstem tests focus on acquiring various types of data. A descriptive test may concentrate on acquiring downhole reservoir fluid samples and pressure data from a shut-in well; a productivity test may focus on identifying maximum flow rates or determining reservoir extent. In exploration and appraisal wells, the primary well test objectives focus on well deliverability, skin, fluid sampling, reservoir characteristics and identification of reservoir extent and faults. 1 In development wells, the objectives are typically linked to measurements of the average reservoir pressure and skin and determination of reservoir characteristics. Well test operations comprise cycles of well flow and shut-in while bottomhole pressures (BHPs) are monitored. eservoir engineers apply these data to make early predictions about reservoir potential through a process known as pressure transient analysis, in which the rate of pressure change versus time during a shut-in and drawdown cycle is plotted on a logarithmic scale. The resulting plots indicate reservoir response patterns that can be associated with specific reservoir models using generalized type curves; the curves help determine reservoir characteristics such as skin, permeability and half-length of induced fractures. The shut-in mechanism must be as close as possible to the point at which formation fluids enter the wellbore to eliminate the influence of wellbore storage on the downhole data. Wellbore storage refers to the volume of fluid in the wellbore that may be compressed or expanded, or to a moving fluid/gas interface as a result of a production rate change. Wellbore storage may exhibit complex behavior below the point of shut-in, such as phase segregation, which can hinder true reservoir response by mixing with or masking reservoir pressure transients. 2 A crucial part of the pressure transient analysis is distinguishing between the effects of wellbore storage and the interpretable reservoir response in the early stages of the test. At various points during the test, technicians may capture representative samples of formation fluids through the test string; fluid capture may be performed using dedicated inline sample carriers equipped with trigger systems or by deploying through-tubing wireline-conveyed samplers. The samples are then sent to a laboratory for detailed PVT analysis in a process that may take several months. 32 Oilfield eview
2 By deploying logging-while-drilling tools such as the StethoScope formation pressure-whiledrilling service, engineers may ascertain initial information about reservoir properties, formation fluid types and producibility. This information is often coupled with wireline log analysis and formation pressure and sampling data after the well has been drilled through the section of interest. In exploration and appraisal wells, these estimates may be associated with some uncertainty, and the reservoir parameters can be confirmed only by monitoring the reservoir under dynamic conditions such as is done with DSTs. Drillstem tests provide complementary data for reservoir and formation fluid characterization and for predicting the reservoir s ability to produce. Of all the data that operators depend on to design well completions, these data include the least amount of uncertainty and the deepest radius of investigation. 3 The duration, producing time and flow rate of a DST provide a deeper investigation into a reservoir than do other reservoir evaluation techniques. As a consequence, well testing provides the bulk of the information engineers need to design well completions and production facilities. Although more efficient, reliable and robust, the primary components of DST assemblies today are similar to those deployed by the Johnston Formation Testing Company in the 1930s. These components consist primarily of four types of devices: packers to provide zonal isolation downhole valves to control fluid flow pressure recorders to facilitate analysis devices to capture representative samples. Changes to test systems over time have been confined mainly to the addition of auxiliary components such as circulating valves, jars, safety joints and other devices aimed at reducing the time required to recover from a stuck testing string or to provide options for killing a well. In recent years, service companies have done much to reduce uncertainty and costs associated with well testing while increasing safety and efficiency. A significant step in this progression includes the Quartet downhole reservoir testing system. The Quartet testing tool allows operators to perform the four essential functions of a DST assembly isolate, control, measure and sample in a single run. The system includes the CTIS high-integrity reservoir test isolation system, the IDV intelligent remote dual valve, Signature quartz gauges and the SCA inline independent reservoir fluid sampling tool. Autumn
3 The CTIS isolation system provides production-level isolation with single-trip retrievability. It includes a floating seal assembly to compensate for tubing movement during well testing and eliminates the need for slip joints and drill collars (below). The IDV dual valve is an intelligent remotely operated tool that allows Stinger Stinger release upture disc Hydraulic setting mechanism atchet lock Seal element Bypass Slips elease ring Sealbore Stinger seal Perforating guns > Isolation system. The CTIS system s hydraulic setting mechanism is activated by applying pressure to a rupture disc; setting does not require string rotation or mechanical movement. To unset the system, an upward force disengages the ratchet lock and shears the retaining pins in the release ring, which allows the slips to relax and release the system. Continued pulling reopens the bypass, which eliminates swabbing while pulling the packer out of the hole. The stinger floats inside the sealbore, which compensates for string movements caused by temperature changes. The system allows gauges to be positioned below it in the test string. Tubing-conveyed perforating guns can be suspended below the body. operators independent control of the tester and circulating valve via commands transmitted by low-pressure annular pulses (below). Signature gauges that have ceramic electronics boards provide high-quality pressure and temperature Circulating valve (closed) Test valve (open) Atmospheric chamber Hydrostatic chamber Pressure sensor Battery >emote dual valve. The IDV intelligent remote dual valve combines a test valve and a circulating valve that may be cycled independently or in sequence. The test valve, the primary barrier during the well test buildup period, is activated through wireless commands or low-pressure pulses. Wireless commands facilitate the independent operation of both valves without interfering with the operation of other tools in the test string. In the open position, the circulating valve allows flow between the tubing and annulus. Low-pressure pulses are detected by the pressure sensor, and the electronics confirm the received command by comparing it with those in a library stored in the tool memory. The IDV valve may be configured to provide wireless feedback, confirming command reception. The activation of both valves is initiated by battery power, which is augmented by a hydraulic fluid circuit that discharges fluid from the atmospheric chamber into the hydrostatic chamber when the valve is operated. measurements at the reservoir (next page, top left). 4 The SCA inline independent reservoir fluid sampling tool collects representative reservoir fluid samples from the flow stream (next page, top right). The accuracy of reservoir property analysis and the degree of reservoir understanding are heavily dependent on the quality of pressure measurements acquired downhole; obtaining accurate measurements hinges on metrology and its parameters. Cornerstone of Pressure Transient Analysis Metrology is the science of measurements based on physics. Technicians use the methods of metrology to ascertain that sensors are properly calibrated to specified or technical parameters (next page, bottom). In the case of pressure gauge metrology, static parameters include the following: Accuracy is the algebraic sum of all the errors that influence the pressure measurement. esolution is the minimum pressure change that can be detected by the sensor and is equal to the sum of sensor resolution, digitizer resolution and electronic noise induced by the amplification chain. Therefore, when determining gauge resolution, engineers must consider the associated electronics and specific sampling time. The resolution of the interpreted range of investigation, or transient drainage radius, depends on the resolution of the gauge. Gauge metrology could impact important decisions operators make in evaluating reservoir size and extent, which is a key objective of well testing interpretation. 5 Stability is the ability of a sensor to retain its performance characteristics for a relatively long period of time and is the sensor mean drift in psi/d at a specified pressure and temperature. The levels of stability include short-term stability for the first day of a test, medium-term stability for the following six days and longterm stability for a minimum of one month. Sensitivity the ratio of the transducer output variation induced by a change of pressure to that change of pressure is the slope of the transducer output curve plotted versus pressure. Dynamic parameters include the following: Transient response during pressure changes is the sensor response recorded before and after a pressure variation while the temperature is kept constant. Transient response during temperature changes is the sensor response monitored under dynamic temperature conditions while the applied pressure is kept constant. This param- 34 Oilfield eview
4 Battery upture disc trigger Buffer fluid Single-phase reservoir sampler Pressure compensation fluid eservoir fluid lectronics Pressure compensation fluid Nitrogen Sensor > The Signature quartz gauge. The Signature gauge consists of a sensor, electronics section and battery. The sensor includes a multichip ceramic module (not shown). eter provides the stabilization time required for a reliable pressure measurement for a given temperature variation. Dynamic response during pressure and temperature changes is the sensor response recorded before and after a change in both pressure and temperature. Pressure data help engineers develop information about the size and shape of the reservoir 4. For more on Signature gauges: Avant C, Daungkaew S, Behera BK, Danpanich S, Laprabang W, De Santo I, Heath G, Osman K, Khan ZA, ussell J, Sims P, Slapal M and Tevis C: Testing the Limits in xtreme Well Conditions, Oilfield eview 24, no. 3 (Autumn 2012): Kuchuk FJ: adius of Investigation for eserve stimation from Pressure Transient Well Tests, paper SP , presented at the SP Middle ast Oil and Gas Show and Conference, Bahrain, March 15 18, > Downhole fluid sampler. The SCA inline independent reservoir fluid sampling tool (left ) captures representative, contaminant-free, single-phase fluid samples directly from the flow stream close to the reservoir. The tool houses the single-phase reservoir sampler (right ). Using a rupture disc triggering mechanism, initiated by applied annular pressure or through wireless command, the sampler can be activated to open a flow channel to capture a sample. The single-phase reservoir sampler has an independent nitrogen charge to ensure each sample remains at or above reservoir pressure. When the triggering mechanism is activated, reservoir fluid is channeled to fill a sample chamber bounded by pressure compensation fluid. The compensation assembly comprises the nitrogen precharge, pressure compensation fluid and buffer fluid, which ensure that the sample chamber slowly provides enough volume to capture the reservoir fluid without altering its properties. and its ability to produce fluids. Pressure transient analysis is the process engineers use to convert these data to useful information. During this process, they analyze pressure changes over time, particularly those changes that are associated with small variations in fluid volume. Gauge Metrology Parameters Static Dynamic Accuracy esolution Stability Sensitivity > Gauge metrology parameters. Transient response during pressure changes During a typical well test, a limited amount of fluid is allowed to flow from the formation while the pressure measurement at the sandface is acquired along with downhole and surface flow rate measurements. After the production period, the well is shut in while downhole pressure data acquisition continues during the buildup. Transient response during temperature changes Dynamic response during simultaneous pressure and temperature changes Autumn
5 Pressure, psi Pressure, psi Pressure, psi ,000 1, Time, s >The impact of high resolution on data quality. Analysts can use high-resolution measurements (top ) acquired using a Signature gauge to deliver a clear interpretation of the pressure data. High-quality pressure data (middle, green) result in a pressure derivative curve (red) that is easily discernable and from which reservoir engineers can identify various pressure regimes during buildup. A low-resolution measurement (bottom) may deliver an uninterpretable dataset. The downhole gauges that capture the reservoir response during the well test must be highly accurate, but high accuracy is difficult to achieve because of the complex wellbore environment. During well tests, fluid dynamics and thermal and mechanical string effects impact tool response. The technology used to capture pressure data has evolved considerably over time. In the 1930s, operators deployed mechanical gauges, which provided resolution of about 35 kpa [5.1 psi] Time, h Time, h These gauges operated by recording the displacement of a pressure sensing element on a sensitive surface, which was rotated by a mechanical clock, thus providing a pressure versus time measurement. The data were digitized manually from the pressure-time chart. Following improvements in electronics design and reliability led by the Hewlett-Packard Company, electronic gauges were introduced to the oil industry in the 1970s. Development of stable electronic gauges with higher levels of accuracy progressed rapidly, and by the turn of the century, two main types dominated the industry. Strain gauges were the first electronic gauges used widely in the oil industry. They operated on the principle of a resistance circuit placed on a pressure sensitive diaphragm. The change in length of the diaphragm in response to pressure altered the balance of a Wheatstone bridge circuit. These strain gauges were capable of 0.7-kPa [0.1-psi] resolution, which may not be sufficient to resolve reservoir properties. Vibrating quartz pressure sensors, developed in the 1970s, signaled a significant shift in the quality of downhole measurements in terms of metrology. Because of their superior metrological characteristics, quartz gauges have become the standard for downhole pressure and temperature acquisition although their accuracy may be affected by sudden changes in downhole temperature and pressure. Quartz sensors use the piezoelectric effect to measure the strain caused by pressure imposed upon the sensing mechanism. The frequency of vibration in relation to pressure changes is measured and converted to digital pressure measurements. The high frequencies of quartz sensors enable measurement of highresolution pressure changes and rapid sensor response. Typical resolution of quartz gauges is 0.07 kpa [0.01 psi]. Today, the Schlumberger Signature CQG gauge, using a proprietary compensated quartz gauge the CQG crystal is able to distinguish pressure measurements as small as kpa [0.003 psi] (left). Signature gauges may be deployed in reservoir tests at temperatures up to 210 C [410 F] and pressures reaching 200 MPa [29,000 psi]. They may be deployed in real-time or memory mode as part of the test string and are contained within gauge carrier mandrels able to hold up to four gauges each. Numerous carriers can be placed in the test string above and below the CTIS isolation system. The challenge of downhole measurements is not limited to the harshness of ambient conditions; three major sources of uncertainty affect downhole pressure measurements during well testing. Uncertainties in gauge resolution and accuracy, which are typically characterized as functions of the magnitude of pressure and temperature changes downhole, may introduce errors. In addition, uncertainty in the condition of the environment may induce error. 6 For example, during the test flowing period, a gas bubble close to the gauge may burst and create high-frequency noise that is of the same order of magnitude as the gauge accuracy and several times larger than the gauge resolution. If the pressure 36 Oilfield eview
6 Type of Test Test Objectives Acquired Data Descriptive Well characteristics Bottomhole pressure and temperature Flowhead eeler Surface PC eservoir characteristics (average reservoir pressure, permeability thickness, storativity ratio and interporosity flow coefficient) Communication between wells and reservoirs (interference and multizone tests) Surface flow rate Interface box Productivity eservoir extent and drive mechanism Bottomhole pressure and temperature 1 Inflow performance ratio (combined well and reservoir) Surface flow rate Hanger Tubing Gauge carrier, Muzic wireless system with Signature gauges SCA sampler CTIS isolation system IDV valve Gauge carrier, Muzic wireless system with Signature gauges > A downhole reservoir testing system enabled by Muzic wireless telemetry. A network of acoustic repeaters, attached to the tubing using a system of clamps, enables remote interrogation of downhole gauges or tools with feedback via computer terminal at the rig. Two repeaters installed in each numbered node supply horizontal redundancy; one repeater is always on standby. Vertical redundancy is provided by repeaters able to communicate across twice the normal spacing between repeaters, which is usually 305 m [1,000 ft] Seabed epeaters > Types of well tests, test objectives and acquired data. Two types of tests descriptive and productivity provide a variety of downhole data. Descriptive tests seek information about well and reservoir characteristics, whereas engineers typically use productivity tests to understand the producing capacity, extent and drive mechanism of a reservoir. Both types require bottomhole pressure, bottomhole temperature and surface flow rates. Sequence and duration of individual flow periods differentiate the test types. changes quickly, and the sampling rate is relatively slow when this occurs, separating high-frequency noise from measurements is difficult. A similar situation arises if phase segregation of small quantities of water and gas in the well effluent occurs. With the introduction of quartz gauges, the parameters of pressure gauge metrology were improved significantly. However, experts recognized that the value of well tests was often impacted by the fact that data were inaccessible until after the tests were complete. To address this shortcoming, they developed a system that allows operators to monitor the progress of a well test as the test proceeds by delivering the downhole pressure and temperature data to the surface in real time. With insights provided by these data, coupled with real-time downhole control, operators would then be able to alter ongoing tests to meet their objectives. eal-time Data, eal-time Decisions To reduce the uncertainty associated with some well and reservoir parameters, engineers typically begin a well test design by defining the objectives of the test (above). The acquisition of wireless real-time bottomhole pressure and temperature data gives operators the ability to manage both the well and reservoir uncertainties, make adjustments during the test and exercise a measure of control over operational and cost challenges associated with traditional DSTs. The sequence and duration of well test operations are based on initial data obtained from various sources, including petrophysical logs and core analysis. Historically, well tests are based on a design-execute-evaluate cycle, in which technicians design and execute the tests to acquire downhole data for evaluation and capture fluid samples for laboratory analysis. Downhole data are most frequently acquired using electronic gauges in memory mode, which do not provide operators with real-time feedback to validate pretest assumptions, to verify that objectives are being achieved or to modify the tests during execution. As a consequence, technicians typically execute the well test program regardless of reservoir response. This can result in unnecessary steps, prolonged tests, missed opportunities and even damage to the reservoir. That the pretest assumptions are wrong or the test is failing to meet objectives is often realized only after the test has been concluded and the memory data have been analyzed. The industry has made attempts to correct this shortcoming by using surface readout (SO) systems. These SO systems deploy electric line tools to recover downhole data from electronic memory gauges that are run as part of the DST toolstring. The data download is typically performed toward the end of the test, which limits any modification of the operation to managing the remainder of the well test operation and does little to improve the overall operational sequence. The practice of deploying electric line tools has become increasingly unpopular with operators in expensive deepwater projects. Operators are concerned that the electric line cable may become snagged or part when it crosses valves. The efficiency of managing well test operations through electric line data acquisition is also limited because it is typically performed only during nonflowing periods; electric line toolstrings are at risk of being forced up the hole when the well is flowing. To address these limitations, Schlumberger engineers developed the Muzic downhole wireless system (left). The Muzic system is designed 6. Onur M and Kuchuk FJ: Nonlinear egression Analysis of Well-Test Pressure Data with Uncertain Variance, paper SP 62918, presented at the SP Annual Technical Conference and xhibition, Dallas, October 1 4, Autumn
7 >Network architecture of the Muzic wireless system. The Muzic wireless network is based on acoustic clamp-on style repeaters (left ) attached to tubing. The transducer generates an acoustic signal (red) encoded with digital information. Bidirectional acoustic energy travels the length of the pipe and is transmitted from each repeater to adjacent repeaters until the signal reaches the user at the surface. With such a series of repeaters, a network architecture (right ) can be established in which transmitting nodes () send and receive information from transmitting hubs and sensing or actuating end nodes (). nd nodes are points of interest for the surface user and include sensors to acquire measurements or actuators to control devices. Pressure and pressure derivative Piezoelectric transducer Clamp Acoustic message Production tubing Memory eal time S Pressure S Pressure derivative Surface repeater epeater nd node Bidirectional acoustic message Time >Comparing Signature gauge real-time data with memory data. Pressure data obtained by a Signature quartz gauge and transmitted wirelessly in real time are a nearly perfect match with data downloaded from memory during a pressure transient well test offshore Indonesia for Total &P. The quartz gauges transmitted real-time bottomhole pressure and temperature data to the surface without interruption for almost seven days. These data allowed pressure transient analysis to be performed in real time and facilitated the validation of the ongoing well test operations versus the Total &P Indonesia test objectives. to be embedded into the Quartet DST string. The system interfaces with the Quartet reservoir testing system to facilitate interactive well testing operations in which the operator has direct access to downhole data in real time and is able to control downhole tools through wireless commands. The distributed digital wireless telemetry system uses an acoustic wave generated in the test string to transmit information. The acoustic network is composed of a series of tools clamped on the outside of downhole test tubing (left). ach tool acts as a repeater and can transmit or receive an acoustic signal as well as allow control of downhole tools through wireless commands. By initiating real-time changes to the proposed testing program, operators can derive the maximum value from each testing operation. Digital data are relayed from one repeater to the next in either direction on their way to their final destination. In the bottomhole assembly, the network interfaces either with downhole pressure gauges for data acquisition or with downhole tester tools (tester valve, circulating valve and sampler) to issue commands and verify tool status. This interactive platform also opens the possibility to expand the scope of reservoir testing to access previously inaccessible parts of the well for instrumentation and tool control. The signal processing techniques used for downhole digital data transmission are similar to methods employed in other wireless communications. However, successful wireless transmission is affected by many things, including pipe or tubing effects, ambient noise and electronics and battery limitations. For acoustic propagation, tubing is a complex medium; its effectiveness in propagating acoustic waves is hampered by noise, attenuation and distortion. For example, each time an acoustic wave goes through a tubing connection, it generates an echo. The series of echoes generated by crossing multiple joints are canceled by advanced signal processing techniques to achieve point-to-point communication. In addition, because the wireless telemetry system relies on acoustic propagation, any increase in ambient noise conditions downhole can adversely impact transmission. Additional engineering challenges arise from the low-power electronics required for long duration battery operation. This low-power requirement limits the choice of downhole processors and impacts the available processing power. To address these challenges, a specific network protocol was developed that manages and optimizes communication through a repeater network. 38 Oilfield eview
8 The Muzic system makes possible a new workflow for real-time testing operations. A decision tree within this workflow includes risk assessment, test planning, data validation, quality assurance and quicklook validation of data during the execution phase. This process allows realtime decisions and adjustments to the testing plan while the test is underway. A eal-time Interpretation Workflow In traditional well testing operations, engineers design, prepare and execute the test and interpret the acquired data in sequence. In this postmortem approach to reservoir characterization, insight obtained during data analysis does not impact the original design or execution phases, and the interpretation usually takes place after operations are concluded. The availability of downhole data and tool status information in real time from technologies such as Muzic wireless telemetry represents a significant shift from the sequential approach. Feedback from the reservoir is immediate and available during the execution phase, allowing the operator to modify the test sequence and operation while the test string is still in the well. eal-time information about the condition of the wellbore and status of downhole tools considerably impacts operational efficiency and gives the operator confidence in the validity of the measurements (above right). Introduction of real-time monitoring into the standard well test workflow reduces overall costs and rig time because the process is driven by actual reservoir responses and not by generally accepted practices and estimates (right). Any erroneous operational steps can be immediately identified and remedied, eliminating uncertainties and the costs of repeat operations as a result of inconclusive operational data. Total &P planned an exploration test of a 45 deviated well offshore ast Kalimantan, Indonesia. The target zone was at 3,200 m [10,500 ft] MD with a bottomhole pressure of 25,000 kpa [3,600 psi] and a bottomhole temperature of 118 C [244 F]. The operator s test objectives were to analyze the downhole pressure transient data and obtain initial estimates of key reservoir properties such as pressure, skin, permeability thickness and boundaries. A solution was designed around Muzic wireless telemetry interfacing with highresolution Signature pressure gauges. The gauges, which proved to provide data that matched nearly perfectly with data gathered using memory gauges, transmitted downhole pressure and temperature for almost seven days (previous page, bottom). This continuous flow of data allowed Pressure, psi ate, bbl/d 8,000 7,000 6,000 5,000 4,000 3,000 2,000 1, ,500 1, Time, d > A real-time dataset overlaid on a memory dataset. In this example, data captured in memory mode (green) and real-time data (red) track perfectly. Data captured in memory mode can be accessed only when they are downloaded after the test is ended. Wireless-enabled reservoir testing, however, allows operators to observe pressures in real time and make decisions accordingly. Information that operators may derive from real-time test data and use to make decisions include tubing conditions while running in the hole (1), underbalance before perforation (2), connectivity after perforation (3), progress of cleanup and flowing periods (4) and buildup (5, blue shading). The flow rate (blue curve) is visible in real time throughout the test. eal-time measurements ceased when the operator began to pull out of the hole after almost seven days. engineers to optimize flow and maintain reservoir conditions below depletion during testing. The reservoir engineer was also able to perform realtime interpretations of pressure transient data and thus validate that test objectives were being 1 Geologic model 3 1 Test design 2 Hardware selection Memory gauge eal-time pressure met. Because the engineers were able to determine the test objectives had been achieved as the test was proceeding, they could shorten the flowing period without fear of losing valuable pressure transient data. Operation and data acquisition 4 6 Final interpretation and validation model, verification and uncertainty eal-time wellsite or remote-site interpretation > A workflow for integrating the test design, execution and interpretation sequence in real time. Muzic wireless telemetry and InterACT collaboration software enable real-time interpretation and analysis for use in updating the geologic model and refining the transient analysis and eventual final reservoir model. The integration process includes information from the geologic model (1) used in test equipment selection (2) and test design (3). Because real-time bottomhole data are available during the test (4), the test results are continuously compared with the initial design expectation, and this output (5) helps in refining the final interpretation (6). This process continues iteratively for each flow period and results in a model with least uncertainty for the reservoir engineer. (Adapted from Kuchuk et al, reference 3.) Autumn
9 Productivity index eal-time productivity index Production logging Cleanup First flow First buildup Second flow Second buildup tool rigup Third flow Time, d > eal-time productivity index mapping during well testing. Using the Muzic system, the operator tracked the productivity index during flow on several choke sizes. BHP eal-time bottomhole pressure Memory bottomhole pressure eal-time annulus pressure Tubing-conveyed perforating (TCP) gun detonation Choke size Time Memory annulus pressure eal-time bottomhole temperature Memory bottomhole temperature Main pressure transient test > Obtaining critical data in real time. The overlap of real-time and memory data demonstrates the accuracy of real-time data and their capability to provide sufficient insight into operational events, even though the real-time data sampling is less dense than memory mode sampling. An inset from a separate test shows TCP gun detonation data (left ); the sharp decrease followed by a sharp increase in pressure confirms in real time the postperforation flow of reservoir fluid into the wellbore. An inset from a separate test showing pressure response during the main pressure transient test (right ) demonstrates that the volume of data captured is adequate for detailed analysis, such as productivity index determination and pressure transient analysis, during flow and buildup periods. Choke size Petrobras engineers working in a presalt environment in the Santos basin offshore Brazil sought to obtain real-time data at the surface during a deepwater well test and to eliminate the wireline run typically required to acquire such data. Schlumberger and Petrobras engineers chose to deploy wireless-enabled Signature gauges in the well, which is in 2,000 m [6,600 ft] of water 250 km [155 mi] off the coast of Brazil. The Muzic wireless telemetry system and pressure and temperature gauges enabled for wireless communication were run in the well. This configuration permitted engineers to receive data during flow and shut-in periods, to monitor cleanup efficiency in real time and to obtain key reservoir information before the end of the test (left). As a consequence, reservoir engineers were able to observe the pressure transient after perforation gun detonation to confirm dynamic underbalance. Petrobras and Schlumberger engineers were also able to confirm downhole valve status, compute productivity as the well was flowing, confirm that sufficient data were acquired during the initial and main buildup periods, eliminate a wireline run and establish the reservoir pressure after the initial postperforating flow period (below left). A common challenge in well test operations is managing the duration of the buildup period. Test operators often calculate a buildup period as an integer multiple of the flowing period duration. By accessing the actual downhole pressure response in real time during the buildup period, engineers are able to determine that the desired reservoir response has been achieved and validated sooner than would be the case using the multiple, thus saving the operator hours of rig time. Conversely, if the reservoir response objective has not been met, the test can be extended. The overall efficiency of the operation is improved because downhole tool status can be verified at each step of the program. Important decisions about the progress of the test can be made with clear understanding of the reservoir response from downhole pressure conditions, which makes the overall operation safer. Using wireless tool activation also takes less time and requires fewer operational steps than do traditional pressure activation methods. eal-time data are important for characterizing the reservoir with the least possible uncertainty. The Muzic system enables remote interpretation through data sharing and collaboration software. Based on a geologic model, the well test is designed and gauges and DST tools are selected to meet certain operational and acquisition criteria. 40 Oilfield eview
10 Pressure ate Pressure ate Plan Initial flow Initial buildup Cleanup Second buildup Main flow Time, d Actual Initial flow Initial buildup Cleanup Second buildup Main flow Main buildup Main buildup Sampling flow 28 hours saved Sampling flow Time, d Flow Period Plan, h Actual, h Initial flow Initial buildup Cleanup flow Second buildup Main flow Main buildup Sampling flow Total > eal-time decision making. A well test, as planned, would have taken nearly five days (top). Using the wireless-enabled downhole reservoir testing system, engineers at Maersk Oil were able to monitor reservoir parameters and make decisions in real time, which shortened the well test by more than a day. eal-time data (middle) allowed the operator to obtain necessary downhole information with which to characterize the reservoir and meet its test objectives in 28 fewer hours than was called for in the original test plan (bottom). During the operation, the downhole pressure and surface rate data acquired by the system are validated in real time, and QA/QC can be performed immediately. ngineers can use these data for quicklook interpretations and to determine well and reservoir parameters. The initial reservoir model may then be updated in real time with the information from the well test to generate a new interpretation model, verified with less uncertainty. The process is multidisciplinary and dynamic; results from interpretation and analysis can be used to modify earlier assumptions in an iterative fashion and continuously generate a clearer picture of the reservoir. Maersk Oil drilled an exploration well offshore Luanda to acquire data that would confirm the presence of hydrocarbons in the target formation. The well was drilled into oil-bearing sandstones; the primary target was at a depth of approximately 5,000 m [16,000 ft] in water depth of 1,462 m [4,797 ft]. Downhole gauges enabled by Muzic wireless telemetry transmitted data successfully throughout the test. The operator was able to verify the underbalance prior to perforating, establish initial reservoir pressure after perforating, verify the status of the downhole tools during the test, optimize the cleanup period by monitoring sandface pressure, reduce duration of buildup and confirm that samples were being taken in ideal conditions. The T Certain real-time test collaboration service brought reservoir experts at the rig in Luanda and in Copenhagen, Denmark, together in a virtual environment. A software platform enabled wellsite data transmission and interpretation tools that allowed experts to make the right decisions on site and from remote locations. This integrated system also helped ensure sufficient data were collected to complete a successful pressure transient well test. The wireless downhole testing system saved 28 hours of rig time, about US$ 1.5 million in rig spread costs, while acquiring sufficient data for key reservoir property estimation (left). A comparison of memory data from the gauges retrieved at the surface with the real-time data used for interpretation during the test validated the decisions made during the operation. The Future of Well Testing ngineers have long recognized the value of DSTs but in certain circumstances have had to make compromises between quality data, costs and risk. eal-time wireless telemetry addresses those compromises by providing a means to capture real-time data throughout the test, remotely activate downhole tools and isolate zones of interest efficiently without permanent packers and the need to collect reservoir fluid samples at specified times. Most importantly, unlike in the past, engineers can be certain they have achieved test objectives before the test is ended. The future of real-time well testing goes beyond transmitting data to include the actuation of multiple devices in the DST string using this same wireless backbone. The immediate reward for these expanded capabilities will be measured in saved time, saved capital and improved ultimate hydrocarbon recovery as a result of development designs and production schedules informed by high-quality data and accurate knowledge of reservoir characteristics. vf Autumn
Argentina Tataru*, Marcel Adrian Piteiu*, Dan-Paul Stefanescu*, Ioana Vlasin*
WIERTNICTWO NAFTA GAZ TOM 24 ZESZYT 1 2007 Argentina Tataru*, Marcel Adrian Piteiu*, Dan-Paul Stefanescu*, Ioana Vlasin* NEW TECHNICAL CONSIDERATIONS OF ROMGAZ COMPANY REGARDING DRILLING, COMPLETION AND
FIBER-OPTIC SENSING TECHNOLOGIES
PRODUCTION ENHANCEMENT FIBER-OPTIC SENSING TECHNOLOGIES FOR WELL MONITORING TO RESERVOIR MANAGEMENT Solving challenges. A H A L L I B U R T O N S E R V I C E Fiber-Optic Sensing Technologies CUTTING-EDGE
Gas Well Deliverability Testing
Gas Well Deliverability Testing What is deliverability testing? The "deliverability" of a gas well can be defined as the well's capacity to produce against the restrictions of the well bore and the system
Fiber Optics in a Bakken Multi-Stage Fractured Well. Montana Tech 2011 SPE Drilling Symposium Presented by: Chelsea Kadler
Fiber Optics in a Bakken Multi-Stage Fractured Well Montana Tech 2011 SPE Drilling Symposium Presented by: Chelsea Kadler Agenda FracPoint Design FracPoint Real-time Monitoring System Downhole Equipment
Reservoir Performance Monitor Formation evaluation and reservoir monitoring
A d v a n c i n g R e s e r v o i r P e r f o r m a n c e Reservoir Performance Monitor Formation evaluation and reservoir monitoring Reservoir Performance Monitor (RPM) Comprehensive reservoir evaluation
Diagnostic Fracture Injection Tests (DFIT ) in Ultra Low Permeability Formations
Diagnostic Fracture Injection Tests (DFIT ) in Ultra Low Permeability Formations Pressure transient testing has been the standard method over the years to obtain important well information such as reservoir
Introduction. The following is an outline of the contents of this paper: Definition of Artificial Lift Page 2. How an Oil Well is Produced Page 2
Introduction Canadian Oilwell Systems Company and it s subsidiaries are suppliers of oil well Electric Submersible Pumping systems (ESPs). Such pumps are used to lift oil from oil wells so that the oil
FlairFlex. Real-time fluid logging and analysis service
FlairFlex Real-time fluid logging and analysis service FlairFlex Real-time fluid logging and analysis service The FlairFlex* service from Geoservices provides early insight into reservoir fluid properties
Certificate Programs in. Program Requirements
IHRDC Online Certificate Programs in OIL AND GAS MANAGEMENT Program Requirements IHRDC 535 Boylston Street Boston, MA 02116 Tel: 1-617-536-0202 Email: [email protected] Copyright International Human
WELL LOGGING TECHNIQUES WELL LOGGING DEPARTMENT OIL INDIA LIMITED
WELL LOGGING TECHNIQUES WELL LOGGING DEPARTMENT OIL INDIA LIMITED The Hydrocarbon E & P Process In the exploration process, a most probable hydrocarbon bearing rock structure is defined based on seismic
WELL COMMANDER Versatile multi-cycle ball-activated drilling valve for mitigating downhole hazards
WELL COMMANDER Versatile multi-cycle ball-activated drilling valve for mitigating downhole hazards Note: Operating instructions updated July 2014 WELL COMMANDER: Versatile multicycle ball-activated drilling
DEPARTMENT OF PETROLEUM ENGINEERING Graduate Program (Version 2002)
DEPARTMENT OF PETROLEUM ENGINEERING Graduate Program (Version 2002) COURSE DESCRIPTION PETE 512 Advanced Drilling Engineering I (3-0-3) This course provides the student with a thorough understanding of
@balance Xpress. Mobile MPD services
@balance Xpress Mobile MPD services Drill faster and reach farther with @balance Xpress mobile MPD services In operations around the world, M-I SWACO enables customers to improve drilling efficiency and
DecisionSpace Well Engineering Software
DATA SHEET DecisionSpace Well Engineering Software DecisionSpace Drilling & Completions Key features Configure the right tools to drill any type of well Dramatically simple to use, complete complex fluids
High Data Rate MWD Mud Pulse Telemetry
High Data Rate MWD Mud Pulse Telemetry Wallace R. Gardner ([email protected]; 713-496-8118) Halliburton P.O. Box 15414 Houston, TX 77242 Abstract The objective of this project is to build and test a
An Introduction to Oil and Gas Well Servicing
An Introduction to Oil and Gas Well Servicing Educational Material from the IOM 3 Oil and Gas Division The global network for the materials cycle Introduction The Institute of Materials, Minerals & Mining
HDD High Definition Data. defining a new standard for Open Hole, Cased Hole & Production Logging
HDD High Definition Data defining a new standard for Open Hole, Cased Hole & Production Logging Get More Accurate Data At No Extra Cost From RECON s Standard Logging Service At 10 samples per foot (33
10 Wireline operations
10 WIRELINE OPERATIONS... 1 10.1 GENERAL... 1 10.2 WELL BARRIER SCHEMATICS... 1 10.3 WELL BARRIER ACCEPTANCE CRITERIA... 1 10.3.1 Well control equipment configuration... 1 10.3.2 Deployment of toolstrings...
C O M P L E T I O N S E R V I C E S
Well Screens Well Screens Contents ProWeld TM ProWeld TM TOP DynoFlo TM DB UniFlo HELICAL Inflow Control Screen UniFlo TM ROI Inflow Control Screen SlimFlo TM Pre-packed CoilFlo TM DB Screen Communication
CLEAR. Hole cleaning and wellbore risk reduction service
CLEAR Hole cleaning and wellbore risk reduction service The CLEAR* hole cleaning and wellbore risk reduction service, delivered by Geoservices, a Schlumberger company, monitors hole cleaning effectiveness
GAS WELL/WATER WELL SUBSURFACE CONTAMINATION
GAS WELL/WATER WELL SUBSURFACE CONTAMINATION Rick Railsback Professional Geoscientist CURA Environmental & Emergency Services [email protected] And ye shall know the truth and the truth shall make you free.
AAPG International Conference: October 24-27, 2004; Cancun, Mexico
STAIR, CRAIG D. Shell International E&P, Inc. New Orleans, LA.; DAWSON, MARK E.P. Halliburton Energy Services Inc. New Orleans, LA ; JACOB, SURESH WellDynamics Inc. Houston, TX; HEBERT, DARRELL D.B. Consultant,
1-4 kg/m3. Long in-line calibration cycles of the gamma density systems may improve measurement accuracy, but this is often not practical subsea.
Generating Greater Accuracy and Robustness from Subsea Multiphase Meters By Finn Erik Berge, Emerson Process Management Subsea multiphase meters have faced a growing number of challenges linked to the
APPLICATIONS OF REAL-TIME WELL MONITORING SYSTEMS
APPLICATIONS OF REAL-TIME WELL MONITORING SYSTEMS Tim Conn, C.E.T., Terry Moffatt, P.Eng. PROMORE Engineering Inc. Introduction It has been an accepted industry practice to utilize continuous measurement
WELLBORE STORAGE. The fluid produced, q, is the sum production of fluid from the wellbore, q wb, and fluid coming from the reservoir, q sf.
Tom Aage Jelmert NTNU Department of Petroleum Engineering and Applied Geophysics WELLBORE STORAGE Immediately after a rate change, part of the production may be due to expansion or compression of fluid
Selection and Determination of Tubing and Production Casing Sizes
CHAPTER 3 Selection and Determination of Tubing and Production Casing Sizes OUTLINE 3.1 Overview 3.2 Overview of Nodal Analysis 3.3 Selection and Determination of Tubing and Production Casing Sizes for
powered by ingenuity Corrosion Logging Well Integrity Measurement
powered by ingenuity Corrosion Logging Well Integrity Measurement Corrosion control in the oil industry is a matter of economics. Probe s corrosion logging tools offer a solution to predict and detect
Drilling Rigs and Well Technology. RAPID RIGS AND WELL TECHNOLOGY Cairn India Limited.
Drilling Rigs and Well Technology RAPID RIGS AND WELL TECHNOLOGY. 2 3 Cairn India has adopted an innovative approach for its onshore drilling program using state-of-the-art custom made Rapid Rig technology
CALDON LEFM 380Ci Gas Ultrasonic Flow Meter. Integrating experience, proven technology and innovation
CALDON LEFM 380Ci Gas Ultrasonic Flow Meter Integrating experience, proven technology and innovation VALVES & MEASUREMENT Cameron s CALDON LEFM 380Ci gas ultrasonic flow meter combines world-leading flow
Florinel ªuþoiu*, Argentina Tãtaru*, Bogdan Simescu* RIGLESS JOBS IN GAS WELLS
AGH DRILLING, OIL, GAS Vol. 30 No. 1 2013 http://dx.doi.org/10.7494/drill.2013.30.1.221 Florinel ªuþoiu*, Argentina Tãtaru*, Bogdan Simescu* RIGLESS JOBS IN GAS WELLS 1. INTRODUCTION At the same time with
66 National Commission on the BP Deepwater Horizon Oil Spill and Offshore Drilling
66 National Commission on the BP Deepwater Horizon Oil Spill and Offshore Drilling Chief Counsel s Report Chapter 4.3: Cement 67 Chapter 4.3 Cement Figure 4.3.1. Typical completed cement job. Well Cementing
BS PROGRAM IN PETROLEUM ENGINEERING (VERSION 2010) Course Descriptions
BS PROGRAM IN PETROLEUM ENGINEERING (VERSION 2010) Course Descriptions PETE201 Introduction to Petroleum Engineering (Core) (1-0-1) The course's main goal is to provide the student with an overview of
WIRELESS INSTRUMENTATION TECHNOLOGY
BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904
Distributed Temperature Sensing - DTS
Intelligent Solutions Distributed Temperature Sensing - DTS Enabling fast, reliable and cost-effective sensing through highly integrated optical measurement systems Fire detection Power cable monitoring
PRAKlA SEISMDS "V V PRAKLA-SEISMOS AG
!\ PRAKlA SEISMDS "V V PRAKLA-SEISMOS AG 1 Bridge - all conlrols and video screens are within easy reach Mast lable to lit various antennae 01 radio survey systems in one beamline THE ESSENTIAL INSTRUMENTATION
Pressure Coring, A New Tool for Unconventional Oil & Gas Characterization. Matt Bjorum Global Product Line Manager
Pressure Coring, A New Tool for Unconventional Oil & Gas Characterization Matt Bjorum Global Product Line Manager Outline Technology Overview Coring Configurations Tool Overview Surface Handling and Data
Nexus. Reservoir Simulation Software DATA SHEET
DATA SHEET Nexus Reservoir Simulation Software OVERVIEW KEY VALUE Compute surface and subsurface fluid flow simultaneously for increased accuracy and stability Build multi-reservoir models by combining
Modelling and Simulation Multi-stage Fracturing Propagation in Tight Reservoir through Horizontal Well
Modelling and Simulation Multi-stage Fracturing Propagation in Tight Reservoir through Horizontal Well Smail ALIOUI (1) (1) Sonatrach First Calgary Petroleums, Association Division, Hassi Messaoud, 30500,
Practical Application of Industrial Fiber Optic Sensing Systems
Practical Application of Industrial Fiber Optic Sensing Systems John W. Berthold and David B. Needham Davidson Instruments, Inc. P.O. Box 130100, The Woodlands, TX 77393 ABSTRACT In this presentation,
Design of High Temperature Electronics for Well Logging Applications
Design of High Temperature Electronics for Well Logging Applications Bernard Parmentier Schlumberger, France [email protected] Ovidiu Vermesan SINTEF, Norway [email protected]
Energize your mind. www.halliburton.com April 2007. Lightweight Cement Meets Challenges of Weak Formations and Depleted Zones
Energize your mind. www.halliburton.com April 2007 Lightweight Cement Meets Challenges of Weak Formations and Depleted Zones Today, operators are forced to drill in increasingly challenging environments
RESERVOIR GEOSCIENCE AND ENGINEERING
RESERVOIR GEOSCIENCE AND ENGINEERING APPLIED GRADUATE STUDIES at IFP School from September to December RGE01 Fundamentals of Geoscience I Introduction to Petroleum Geosciences, Sedimentology RGE02 Fundamentals
Deepwater Horizon Accident Investigation Report
Deepwater Horizon Accident Investigation Report September 8, 2010 This is the report of an internal BP incident investigation team. The report does not represent the views of any individual or entity other
Drilling Problems. pull
Drilling Problems Pipe Sticking Lost Circulation Hole Deviation Pipe Failures Borehole Instability Mud Contamination Formation Damage Hole Cleaning H S General Equipment & Personnel Pipe Sticking Can not
Computer Network. Interconnected collection of autonomous computers that are able to exchange information
Introduction Computer Network. Interconnected collection of autonomous computers that are able to exchange information No master/slave relationship between the computers in the network Data Communications.
Total Subsea Solutions
Total Subsea Solutions Total Subsea Solutions Developing new energy reserves, managing, and improving producing fields means an unprecedented number of technical challenges. In partnership with our customers,
Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM
Force measurement Forces VECTORIAL ISSUES In classical mechanics, a force is defined as "an action capable of modifying the quantity of movement of a material point". Therefore, a force has the attributes
telemetry Rene A.J. Chave, David D. Lemon, Jan Buermans ASL Environmental Sciences Inc. Victoria BC Canada [email protected] I.
Near real-time transmission of reduced data from a moored multi-frequency sonar by low bandwidth telemetry Rene A.J. Chave, David D. Lemon, Jan Buermans ASL Environmental Sciences Inc. Victoria BC Canada
PanSystem Well-Test Analysis Software
PanSystem Well-Test Analysis Software Production optimization Drilling Evaluation Completion Production Intervention Artificial lift Control systems Flow measurement Reservoir monitoring Software Analysis
DecisionSpace. Prestack Calibration and Analysis Software. DecisionSpace Geosciences DATA SHEET
DATA SHEET DecisionSpace Prestack Calibration and Analysis Software DecisionSpace Geosciences Key Features Large-volume prestack interpretation and analysis suite Advanced prestack analysis workflows native
Plug and Abandonment Forum
Plug and Abandonment Forum Developments in Non-Traditional Plug and Abandonment Methods Thomas Ferg ConocoPhillips Norway June 13, 2013 Efficient P&A Thoughts - Do as Much as Possible Without a Rig Remove
Stilling Well Recommendations
White Paper June 24, 2009 Stilling Well Recommendations This document describes general requirements for stilling wells used for radar tank gauging applications. Automation solutions for oil & gas, defense
LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring
LNG Monitoring Fiber-Optic Leakage Detection System Pipeline leakage detection Regasification and liquefaction monitoring Tank annulus and base slab monitoring Spill containment control Intelligent Solutions
In Development. Shale Liquids Production Analysis. Value. Key Deliverables. Principal Investigator: Investment per Sponsor $52K (USD)
In Development Principal Investigator: Ian Walton, Ph.D. Senior Research Scientist Email: [email protected] Shale Liquids Production Analysis Value Ø Provide a sound method of analyzing and interpreting
Graduate Courses in Petroleum Engineering
Graduate Courses in Petroleum Engineering PEEG 510 ADVANCED WELL TEST ANALYSIS This course will review the fundamentals of fluid flow through porous media and then cover flow and build up test analysis
Fundamentals of Mass Flow Control
Fundamentals of Mass Flow Control Critical Terminology and Operation Principles for Gas and Liquid MFCs A mass flow controller (MFC) is a closed-loop device that sets, measures, and controls the flow of
Noise associated with the ground water systems serving residential geothermal heat pumps
Noise associated with the ground water systems serving residential geothermal heat pumps Jeffrey L. FULLERTON 1 Acentech Incorporated, United States ABSTRACT Geothermal heat pumps are an energy efficient
Hydraulic Fracturing Operations Well Construction and Integrity Guidelines API GUIDANCE DOCUMENT HF1 FIRST EDITION, OCTOBER 2009
Hydraulic Fracturing Operations Well Construction and Integrity Guidelines API GUIDANCE DOCUMENT HF1 FIRST EDITION, OCTOBER 2009 Hydraulic Fracturing Operations Well Construction and Integrity Guidelines
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER
PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER Lufan Zou and Taha Landolsi OZ Optics Limited, 219 Westbrook Road, Ottawa, ON, Canada, K0A 1L0 E-mail:
THE STRAIN GAGE PRESSURE TRANSDUCER
THE STRAIN GAGE PRESSURE TRANSDUCER Pressure transducers use a variety of sensing devices to provide an electrical output proportional to applied pressure. The sensing device employed in the transducers
Well Test Analysis in Practice
Well Test Analysis in Practice Alain C. Gringarten, Imperial College London Why Do We Test Wells? The main reason for testing an exploration well is to take a fluid sample. Further reasons are to measure
4D reservoir simulation workflow for optimizing inflow control device design a case study from a carbonate reservoir in Saudi Arabia
4D reservoir simulation workflow for optimizing inflow control device design a case study from a carbonate reservoir in Saudi Arabia O. Ogunsanwo, 1* B. Lee, 2 H. Wahyu, 2 E. Leung, 1 V. Gottumukkala 1
EVALUATION OF WELL TESTS USING RADIAL COMPOSITE MODEL AND DIETZ SHAPE FACTOR FOR IRREGULAR DRAINAGE AREA. Hana Baarová 1
The International Journal of TRANSPORT & LOGISTICS Medzinárodný časopis DOPRAVA A LOGISTIKA Mimoriadne číslo 8/2010 ISSN 1451 107X EVALUATION OF WELL TESTS USING RADIAL COMPOSITE MODEL AND DIETZ SHAPE
TECHNICAL PUBLICATION
TECHNICAL PUBLICATION Title: Permanent Wellbore Monitoring Components of the Page 1/9 COPYRIGHT NOTATION: This paper is copyright material of PROMORE, A Core Laboratories Company. Publication rights are
Procon Engineering. Technical Document PELR 1002. TERMS and DEFINITIONS
Procon Engineering Technical Document PELR 1002 TERMS and DEFINITIONS The following terms are widely used in the weighing industry. Informal comment on terms is in italics and is not part of the formal
The Precharge Calculator
5116 Bissonnet #341, Bellaire, TX 77401 Telephone and Fax: (713) 663-6361 www.mcadamsengineering.com The Precharge Calculator Purpose: The Precharge Calculator by Interlink Systems, Inc. is a Windows based
The ever increasing importance of reservoir geomechanics
SPE special Interest Reservoir Group, Calgary March 26, 2014 The ever increasing importance of reservoir geomechanics Antonin (Tony) Settari TAURUS Reservoir Solutions Ltd., Calgary Professor Emeritus,
Woods Hole Group, Inc. Oceanography and Measurement Systems Division INTEGRATED REAL-TIME MONITORING SYSTEM
Woods Hole Group, Inc. INTEGRATED REAL-TIME MONITORING SYSTEM Woods Hole Group, Inc. (WHG) has developed the Integrated Real-time Monitoring System (IRMS) as a general-purpose data acquisition and telemetry
Various Technics of Liquids and Solids Level Measurements. (Part 3)
(Part 3) In part one of this series of articles, level measurement using a floating system was discusses and the instruments were recommended for each application. In the second part of these articles,
Implementing New Technology at TransCanada Meter Stations -- Better, Faster, Cheaper
2001 Canadian Gas Association Gas Measurement School Winnipeg, Manitoba Implementing New Technology at TransCanada Meter Stations -- Better, Faster, Cheaper Prepared by: Dean Mah, P.Eng. Warren Peterson
The Do s and Don ts of Pressure Transducers
The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed
Energy savings in commercial refrigeration. Low pressure control
Energy savings in commercial refrigeration equipment : Low pressure control August 2011/White paper by Christophe Borlein AFF and l IIF-IIR member Make the most of your energy Summary Executive summary
PRESIDENT ENERGY PLC. ( President or the Company ) PARAGUAY UPDATE
PRESIDENT ENERGY PLC ( President or the Company ) PARAGUAY UPDATE Highlights Lapacho well flows condensate and gas from the Santa Rosa Formation Management now have enough evidence to view commercialisation
New Generation of Deepwater BOP Stacks. Dominique Allegre CAMERON Paris, October 23rd 2013
New Generation of Deepwater BOP Stacks Dominique Allegre CAMERON Paris, October 23rd 2013 Agenda: Evolution of Standards API Standard 53 RP 17W New Equipment & Technology Developments: Shearing Technology
Barometric Effects on Transducer Data and Groundwater Levels in Monitoring Wells D.A. Wardwell, October 2007
Barometric Effects on Transducer Data and Groundwater Levels in Monitoring Wells D.A. Wardwell, October 2007 Barometric Effects on Transducer Data Barometric Fluctuations can Severely Alter Water Level
Tax Executives Institute
Tax Executives Institute Texas Oil and Gas Transactions May 6, 2013 Circular 230 disclaimer Any US tax advice contained herein was not intended or written to be used, and cannot be used, for the purpose
Automatic Fire Fighting Monitors
Automatic Fire Fighting Monitors Fire Protection Solutions Automatic Fire Fighting Monitors Foreword Automatic monitors are devices used to deliver large amounts of water or water/foam solution to remote
Gas Custody Transfer Calibration
Gas Custody Transfer Calibration Using multi variable temperature / pressure calibrators for flowmeter calibration 2013 Introduction Gas custody transfer flow computers require special calibration to perform
Perforating Basics. How the perforating processes work. George E. King Engineering GEKEngineering.com 3/14/2009 1
Perforating Basics How the perforating processes work 3/14/2009 1 Perforating Methods 1. The vast majority of all perforating work is performed with shaped charge or jet perforating charges. 2. Bullet
Calibration and Use of a Strain-Gage-Instrumented Beam: Density Determination and Weight-Flow-Rate Measurement
Chapter 2 Calibration and Use of a Strain-Gage-Instrumented Beam: Density Determination and Weight-Flow-Rate Measurement 2.1 Introduction and Objectives This laboratory exercise involves the static calibration
Well deliverability test of Kailastila gas field (Well no. KTL-01, KTL-02)
Journal of Petroleum and Gas Exploration Research (ISSN 76-6510) Vol. (10) pp. 188-193, November, 01 Available online http://www.interesjournals.org/jpger Copyright 01 International Research Journals Full
GETTING STARTED WITH LABVIEW POINT-BY-POINT VIS
USER GUIDE GETTING STARTED WITH LABVIEW POINT-BY-POINT VIS Contents Using the LabVIEW Point-By-Point VI Libraries... 2 Initializing Point-By-Point VIs... 3 Frequently Asked Questions... 5 What Are the
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson
Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology HWEA 2011 Conference Craig S. Johnson Presentation Overview Introduction Aeration Air & Digester gas challenges Gas flow metering
Measuring Temperature withthermistors a Tutorial David Potter
NATIONAL INSTRUMENTS The Software is the Instrument Application Note 065 Measuring Temperature withthermistors a Tutorial David Potter Introduction Thermistors are thermally sensitive resistors used in
Rackmount Intelligent Pressure Scanners
Rackmount Intelligent Pressure Scanners NetScanner System 9816/98RK-1 FEATURES ±0.05% Accuracy 100 Hz EU Throughput Autonegotiating 10/100/1G Base T Ethernet - TCP and UDP Protocol Pressure Ranges up to
SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS
July 14, 2015 1.0 GENERAL BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS This work shall consist of furnishing all materials, equipment, labor, and incidentals necessary for conducting bi-directional
APPLICATION OF TRANSIENT WELLBORE SIMULATOR TO EVALUATE DELIVERABILITY CURVE ON HYPOTHETICAL WELL-X
PROCEEDINGS, Thirty-Third Workshop on Geothermal Reservoir Engineering Stanford University, Stanford, California, January 8-30, 008 SGP-TR-185 APPLICATION OF TRANSIENT WELLBORE SIMULATOR TO EVALUATE DELIVERABILITY
Understanding the Flo-Dar Flow Measuring System
Understanding the Flo-Dar Flow Measuring System Independent tests verify non-contact flowmeter is highly accurate under both open channel and surcharge conditions TM Flo-Dar is the only non-contact open
STANDARD OPERATING PROCEDURE
STANDARD OPERATING PROCEDURE DATA ACQUISITION USING THE C1 MEMOCONE SYSTEM REVISION DATE: OKT 21, 2011 Prepared by Per Ljunggren TABLE OF CONTENTS STANDARD OPERATING PROCEDURE...3 DATA ACQUISITION USING
UPM 15010. Figure 1 MPFM installed on well pad
UPM 151 In-line Multiphase Flowmeter Field Trial Comparison vs. Three Phase Flow Separator on Naturally Flowing Shale Wells A. Michael Jones, Independent Flow Measurement Consultant, Travis Gaskill, Daniel
Enhanced Category 5 Cabling System Engineering for Performance
Engineering for Performance Table of Contents 2 Introduction 2 Where Did It Come From? 2 Enhanced Category 5 Performance What to Test The Link The Channel Don t Forget the Cable Assembly 4 Performance
From Control Loops to Software
CNRS-VERIMAG Grenoble, France October 2006 Executive Summary Embedded systems realization of control systems by computers Computers are the major medium for realizing controllers There is a gap between
WellCAP IADC WELL CONTROL ACCREDITATION PROGRAM
WellCAP IADC WELL CONTROL ACCREDITATION PROGRAM WORKOVER & COMPLETION OPERATIONS CORE CURRICULUM AND RELATED FORM WCT-2WF FUNDAMENTAL LEVEL The purpose of the core curriculum is to identify a body of knowledge
powered by ingenuity Permanent Monitoring Optimizing Reservoir Performance
powered by ingenuity Permanent Monitoring Optimizing Reservoir Performance Permanent Monitoring Optimizing Reservoir Performance Probe offers a complete range of permanent downhole gauges, wireless surface
P roduction Logging for Reservoir Te s t i n g
P roduction Logging for Reservoir Te s t i n g Using production logging tools to test wells provides a more accurate analysis of re s e rv o i r parameters, such as permeability and skin damage. Measuring
STRUCTURAL HEALTH MONITORING AT ROME UNDERGROUND, ROMA, ITALY
Ref: WhP_Rome_vA STRUCTURAL HEALTH MONITORING AT ROME UNDERGROUND, ROMA, ITALY WHITE PAPER Summary: This white paper shows how Structural Health Monitoring (SHM), helps to improve the quality in the construction
MUDSOLV NG. Integrated filter-cake removal service for optimizing performance of open-hole completions
MUDSOLV NG Integrated filter-cake removal service for optimizing performance of open-hole completions MUDSOLV NG: Comprehensive filter-cake breaker service A properly formulated and carefully maintained
M.S Ramaiah School of Advanced Studies - Bangalore. On completion of this session, the delegate will understand and be able to appriciate:
Transmission Control Lecture delivered by: Prof. Ashok C.Meti MSRSAS-Bangalore 1 Session Objectives On completion of this session, the delegate will understand and be able to appriciate: Rl Role of electronic
Interpreting Uncemented Multistage Hydraulic Fracturing Completion Effectiveness Using Fiber-Optic DTS Injection Data
Interpreting Uncemented Multistage Hydraulic Fracturing Completion Effectiveness Using Fiber-Optic DTS Injection Data E.H. Holley, SPE, Pinnacle A Halliburton Service; M.M. Molenaar, SPE, Shell Canada