Keysight Series Portable Logic Analyzers. Data Sheet
|
|
|
- Amie Kennedy
- 10 years ago
- Views:
Transcription
1 Keysight Series Portable Logic Analyzers Data Sheet
2 02 Keysight Series Portable Logic Analyzers - Data Sheet Series Portable Logic Analyzer Selection Guide 2.5 GHz timing capture with up to 128 M sample memory for finding elusive problems quickly, even far from the trigger point Up to 1.4 GHz trigger sequencer speed for state and timing capture Single-ended and differential probing for the widest range of supported technologies 80 ps resolution (12.5 GHz) Timing Zoom with 256 K samples allows you to observe signal timing in proximity to the trigger point Up to 1.4 Gbps state data rate tracks high speed parallel and serial buses in your design Gain signal integrity insight on all channels using exclusive eye scan Four models with 34/68/102/136 channels provide the measurement flexibility for a wide range of applications Application support for many aspects of today s complex designs bring target insight FPGA dynamic probe, and digital VSA (vector signal analysis) Powerful, customizable triggering quickly isolates problems Proven, easy to use interface speeds debug Standard 15 inch touch screen allows viewing of multiple buses and signals Standard 3-year warranty Specifications and characteristics 16851A 16852A 16853A 16854A Channels Maximum timing sample rate (half/full channel) 5 GHz (200 ps) with up to 256 M depth 2.5 GHz (400 ps) with up to 128 M depth High-speed timing zoom 12.5 GHz (80 ps) with 256 Kb depth Trigger sequencer 1.4 GHz Maximum state clock rate 700 MHz with Option MHz standard Maximum state data rate 1400 Mb/s with Option Mb/s standard Maximum memory depth 2 M default 4 M with Option M with Option M with Option M with Option M with Option M with Option 128 Supported signal types Single-ended, differential Automated threshold/sample position Yes Simultaneous eye diagrams, all channels Yes Probe compatibility Direct connect single-ended flying lead Direct connect Mictor probe 90-pin connector single-ended and differential probes for flying lead, Mictor, Soft Touch, Soft Touch Pro, and Samtec connections (used in conjunction with a U4201A cable) Select DDR2/3 BGA probes and probe cables Select DDR3 Addr/Cmd slot interposer probes
3 03 Keysight Series Portable Logic Analyzers - Data Sheet Industry s Fastest Timing Capture with Deep Memory for Fast Digital System Debug The Keysight Technologies, Inc Series portable logic analyzers offer the highest performance, with deep, high speed timing and state measurements, combined with the applications and usability your digital development teams need to debug their modern systems and at a great price. Figure 1. With four models to choose from, and options to upgrade state speed and memory depth, you can get a logic analyzer with measurement capabilities that meet your needs. The logic analyzer s timing and state acquisition gives you the power to: Observe timing relationships far away from the trigger point using 2.5 GHz (400 ps)/5 GHz (200 ps) full/half channel timing with up to 128 M samples Measure more precise timing relationships in the vicinity of the trigger point using 12.5 GHz (80 ps) Timing Zoom (256 K samples) Find anomalies separated in time with memory depths upgradable to 128 M Probe a variety of technologies with single-ended and differential attachment options with the highest signal integrity Buy what you need today and upgrade in the future Series logic analyzers come with independent upgrades for state speed and memory depth Sample synchronous buses up to 1400 Mbps data rates accurately using eye scan to automatically adjust threshold and setup/hold Easily track problems from symptom to root cause across several measurement modes by viewing time-correlated data in waveform/chart, listing, inverse assembly, source code, or compare display Identify potential signal integrity issues on high data rate signals by observing an analog view of all input channels via logic analyzer probing with eye scan Set up triggers quickly and confidently with intuitive, simple, quick, and advanced triggering options Time correlate and import oscilloscope/mixed-signal traces into the logic analyzer Waveform window for even greater system insight Automate the capture of internal FPGA signals Series logic analyzers, used with the FPGA Dynamic Probe, let you probe internal FPGA nets on Xilinx and Altera devices with deep memory and through an automated process No block RAM required Move probe points without stopping the FPGA or changing design timing Import signal names automatically from the FPGA design Automatically map FPGA pins to logic analyzer input channels (Xilinx) B4655A (Xilinx) B4656A (Altera) Decode DDR2/3 memory Addr/Cmd buses and perform compliance and performance analysis
4 04 Keysight Series Portable Logic Analyzers - Data Sheet Eye Scan to Set Sample Points and to View Signal Integrity Automate measurement setup and quickly gain diagnostic clues Series logic analyzers make it easy for you to get up and running quickly by automating your measurement setup process. In addition, the logic analyzer s setup/hold window (or sampling position) and threshold voltage settings are automatically determined so you can capture data on high-speed buses with the highest accuracy. Auto Threshold and Sample Position mode allow you to... Obtain accurate and reliable measurements Save time during measurement setup Gain diagnostic clues and identify problem signals quickly Scan all signals and buses simultaneously or just a few View results as a composite display or as individual signals See skew between signals and buses Find and fix inappropriate clock thresholds Measure data valid windows Identify signal integrity problems related to rise times, fall times, data valid window widths Figure 2. Eye scan automatically sets sample positions for accurate state capture and also provides a signal integrity view of each input signal, without the need for an oscilloscope. Identify problem signals over one hundred channels simultaneously As timing and voltage margins continue to shrink, confidence in signal integrity becomes an increasingly vital requirement in the design validation process. Eye scan lets you acquire signal integrity information on all the buses in your design, under a wide variety of operating conditions, in a matter of minutes. Identify problem signals quickly for further investigation with an oscilloscope. Results can be viewed for each individual signal or as a composite of multiple signals or buses.
5 05 Keysight Series Portable Logic Analyzers - Data Sheet Series Logic Analyzer Specifications and Characteristics Number of channels 34 (1 clock + 1 clock qualifier) 16851A 16852A 16853A 16854A 68 ( 1 clock (1 clock + 3 clock qualifiers) 3 clock qualifiers) 136 (1 clock + 3 clock qualifiers) Deep timing (asynchronous) sampling mode Maximum sample rate in full channel mode (nom) Maximum sample rate in half channel mode (nom) Sample period on all channels (nom) Sample period in half channel mode (nom) Minimum data pulse width (nom) Maximum time between transitions (nom) Time interval accuracy within a 16 channel pod (typ) 1 Time interval accuracy across 16 channel pods (typ) 1 1. With single-ended flying lead and Soft Touch Pro probes. Conventional and transitional timing (up to 128 M depth) 2.5 GHz 5 GHz 400 ps to 10 ns 200 ps 1 sample period ps 66 days ± (1 sample period ps % of time interval reading) ± (1 sample period ps % of time interval reading) Timing zoom (captured simultaneously with timing or state sampling mode capture) Timing analysis sample rate (nom) 12.5 GHz (80 ps sample resolution) Time interval accuracy (nom) Within a 16 channel block Between 16 channel blocks ± (80 ps ps % of time interval reading) ± (80 ps ps % of time interval reading) Memory depth (nom) 256 K samples Trigger position (nom) Start, center, end, or user-defined Minimum data pulse width (nom) 1 sample period ps State (synchronous) sampling mode Maximum state data rate base (spec) Maximum state data rate Option 700 (spec) Maximum state clock frequency single edge clocking base (typ) Maximum state clock frequency single edge clocking Option 700 (typ) Minimum state clock frequency (typ) 1 Minimum data valid window (typ) 2 Sample position adjustment resolution (typ) Sample position adjustment accuracy (typ) Minimum data valid window (typ) 1 Minimum setup time (typ) Minimum hold time (typ) Minimum eye height (typ) Sample position adjustment range (typ) Minimum state clock pulse width single edge (typ) Minimum time between active clock edges standard (typ) Minimum time between active clock edges Option 700 (typ) Maximum time between active clock edges (typ) 1 Clock qualifier setup time (typ) Clock qualifier hold time (typ) Time tag resolution (typ) Maximum time count between stored states (nom) 1. Clock can pause for up to 66 days once every 8 or more edges. 2. Dependent on probing system. 700 Mb/s using both edges of clock (spec) 1.4 Gb/s using both edges of clock (spec) 350 MHz 700 MHz 12.5 MHz (single edge) 6.25 MHz (both edges) 160 ps 20 ps ± 150 ps 160 ps 80 ps 80 ps 160 mv 7 ns 200 ps 1429 ps 714 ps 80 ns (single edge) 200 ps 200 ps 80 ps 66 days
6 06 Keysight Series Portable Logic Analyzers - Data Sheet Series Logic Analyzer Specifications and Characteristics (Continued) Trigger characteristics (conventional timing, transitional timing, and state sampling modes) Maximum trigger sequence speed (standard) (nom) 700 MHz (state), 1.4 GHz (timing) Maximum trigger sequence speed (option 700) (nom) 1.4 GHz Maximum trigger sequence levels (nom) 8 Trigger sequence level branching (nom) Arbitrary 4-way if/then/else Trigger position (nom) Start, center, end or user-defined Trigger resources (nom) 16 patterns evaluated as =,!=, >, >=, <, <= 8 double-bounded ranges evaluated as in range, not in range 4 edge detectors in timing, 3 in transitional timing 1 occurrence counter per sequence level 1 timer 3 flags 1 arm in Trigger resource Boolean conditions (nom) Arbitrary Boolean combinations Trigger actions (nom) Go To Trigger and fill memory Trigger and Go To Trigger, send , and fill memory Occurrence counter reset Store qualification actions (nom) Default (global) and per sequence level Store/don t store sample Turn on/off default storing Timer actions Start from reset Stop and reset Pause Resume Flag actions Set Clear Pulse set Pulse clear Maximum occurrence counter (nom) 999,999,999 Maximum pattern width (nom) 128 bits single label Maximum range width (nom) 64 bits Timers range (nom) 200 * sample clock period to 27 hours Timer resolution (nom) 5 ns Timer accuracy (typ) ± (8 * sample clock period + 2ns %) Timer reset latency (nom) 80 * sample clock period General Input signal amplitude V amptd (typ) 350 mv Supported signal types Voltage threshold (typ) Threshold resolution (typ) Threshold accuracy (typ) Threshold setting granularity Single-ended and differential 5 V to +5 V 2 mv ± (30 mv + 1% of setting) Individual threshold for each channel 1. Specification (spec): Represents warranted performance of a calibrated instrument that has been stored for a minimum of 2 hours within the operating temperature range of 0 to 40 C, unless otherwise stated, and after a 45-minute warm-up period. The specifications include measurement uncertainty. 2. Typical (typ): Represents characteristic performance, which 80% of the instruments manufactured will meet. This data is not warranted, does not include measurement uncertainty, and is valid only at room temperature (approximately 25 C). 3. Nominal (nom): The expected mean or average performance, or an attribute whose performance is by design, such as the 50 Ω connector. This data is not warranted and is measured at room temperature (approximately 25 C). 4. Measured (meas): An attribute measured during the design phase for purposes of communicating expected performance, such as amplitude drift versus time. This data is not warranted and is measured at room temperature (approximately 25 C).
7 07 Keysight Series Portable Logic Analyzers - Data Sheet Unleash the Complementary Power of a Logic Analyzer and an Oscilloscope Seamless oscilloscope integration with View Scope Easily make time-correlated measurements between Keysight logic analyzers and oscilloscopes. The timecorrelated logic analyzer and oscilloscope waveforms are integrated into a single logic analyzer waveform display for easy viewing and analysis. You can also trigger the oscilloscope from the logic analyzer (or vice versa), automatically de-skew the waveforms and maintain marker tracking between the two instruments. View Scope allows you to perform the following more effectively: Validate signal integrity Track down problems caused by signal integrity Validate correct operation of A/D and D/A converters Validate correct logical and timing relationships between the analog and digital portions of a design Connection The Keysight logic analyzer and oscilloscope can be physically connected with standard BNC and LAN connections. Two BNC cables are connected for cross triggering, and the LAN connection is used to transfer data between the instruments. The View Scope correlation software is standard in the logic analyzer s application software version 3.50 or higher. The View Scope software includes: Ability to import some or all of the captured oscilloscope waveforms Auto scaling of the scope waveforms for the best fit in the logic analyzer display Figure 3. View Scope seamlessly integrates your scope and logic analyzer waveforms into a single display. Feature Automated setup Integrated waveform display Automatic measurement deskew Cross trigger the logic analyzer and oscilloscope Tracking markers Benefit Quickly get to your first measurement using the logic analyzer s Help wizard for easy setup, regardless of which supported Keysight oscilloscope you connect to. Instantly validate the logical and timing relationships between the analog and digital portions of your design. View oscilloscope and logic analyzer waveforms integrated into a single logic analyzer waveform display. Save time and gain confidence in measurement results with measurements that are automatically de-skewed in time. Start your debug approach from either the analog or digital domain with the flexibility to trigger the oscilloscope from the logic analyzer (or vice versa). Precisely relate information on the oscilloscope s display to the corresponding point in time on the logic analyzer display with tracking markers. The oscilloscope s time markers automatically track adjustments of the logic analyzer s global markers.
8 08 Keysight Series Portable Logic Analyzers - Data Sheet Get Instant Insight into your Design with Multiple Views and Analysis Tools Acquisition and analysis tools provide rapid insight into your toughest debug problems When you want to understand what your target is doing and why, you need acquisition and analysis tools that rapidly consolidate data and provide insight into your system s behavior. Figure 4. Perform in-depth time, frequency and modulation domain analysis on your digital baseband and IF signals with Keysight s Vector Signal Analysis software, running on the logic analyzer. Optional analysis and automated measurement packages B4655A FPGA Dynamic Probe (Xilinx), B4656A FPGA Gain unprecedented visibility into your FPGA s internal activity. Make incremental real-time Dynamic Probe (Altera) measurements in seconds without stopping the FPGA, changing the design or modifying design timing. Quickly set up the logic analyzer with automatic pin mapping and signal bus naming by leveraging work you did in your design environment B-300 digital vector signal analysis, hardware Perform time-domain, spectrum, and modulation quality analysis on digital Baseband and IF connectivity for logic analyzers signals. B4601C serial-to-parallel analysis package Eliminate the tedious, time-consuming, and error-prone task of sifting through thousands of analysis package serial bits by looking at long vertical columns of captured 1 s and 0 s. The B4601C serial-to-parallel analysis package is general-purpose software that allows easy viewing and analysis of serial data. B4602A signal extractor tool This tool processes input signals and based on xml algorithms and creates a mapping of captured signals into new bus and signal names. B4606A advanced customization environment development and runtime package B4607A advanced customization environment runtime package B4608A ASCII remote programming interface B4610A data import package B4630A MATLAB connectivity and analysis package Tailor your logic analyzer interface with a wide range of control, analysis and display capabilities specific to your measurement application. Create integrated dialogs, graphical displays and analysis functions to quickly manipulate measurement data into a format that provides additional insight and answers. Run the macros and graphical views created with a B4606A development package or obtain and run a variety of commonly requested tools from Keysight and its partners to help customize your measurement environment. Remotely control a Series logic analysis system by issuing ASCII commands. This interface is designed to be as similar as possible to the RPI on the Series logic analysis system, so that you can reuse existing programs. Requires either B4606A or B4607A to be enabled. You can also use the B4606A to customize and add RPI commands. Use the logic analyzer GUI to view data obtained from tools other than a logic analyzer. Make an easy connection to MATLAB and transfer your logic analyzer measurement data for processing. Display the results on the logic analyzer in an XY scattergram chart.
9 09 Keysight Series Portable Logic Analyzers - Data Sheet Validate your DDR2 and DDR3 Memory Systems The state analysis capabilities of the Series allow it to make measurements and analysis on DDR2 and DDR3 memories up to DDR2/ (667 MHz clock) on address and control lines. Memory bus decode, compliance testing, and performance analysis are available in state mode only with related orderable tools. Addr/Cmd only Addr/Cmd/Data DDR2 memory DDR3 memory Up to DDR (667 MHz clock) state measurements on Up to DDR (667 MHz clock) state measurements on Addr/Cmd only. (No Data) Addr/Cmd only. (No Data) Requires 34 channel model or higher (one U4201A cable required providing two 90 pin pods) Related Orderable SW Tools (State mode only): B4621B Bus Decoder for DDR, DDR2, DDR3, DDR4 Debug and Validation (Only DDR2 and DDR3 are supported with the Series logic analyzer.) B4622B Protocol Compliance and Analysis Toolset for DDR/2/3/4, and LPDDR/2/3 (Only DDR2 and DDR3 are supported with the Series logic analyzer.) Supported probes with configuration files: Supported probes with configuration files: x16 Addr/Cmd/Data DDR2 BGA probe (W2631B)(Requires x16 Addr/Cmd/Data DDR3 BGA probe (W3631A)(Requires E5384A ZIF probe) 1 E5845A ZIF probe) 1 x8 Addr/Cmd/Data DDR2 BGA probe (W2633B)(Requires x8 Addr/Cmd/Data DDR3 BGA probe (W3633A) (Requires E5384A ZIF probe) 1 E5847A ZIF probe) 1 FS2372 DDR3 DIMM interposer (Addr/Cmd only) FS2374 DDR3 SODIMM interposer (Addr/Cmd only) Up to DDR2 800 (400 MHz clock) timing measurements Up to DDR3 800 (400 MHz clock) timing measurements using using 2.5 GHz timing analyzer with deep memory (for 3:1 ratio 2.5 GHz timing analyzer with deep memory (for 3:1 ratio of of sample rate to data rate) sample rate to data rate) Requires 68 channel model or higher (two U4201A cables using three of the four 90 pin pods provided) Supported probes with configuration files: Supported probes with configuration files: x16 Addr/Cmd/Data DDR2 BGA probe (W2631B)(Requires x16 Addr/Cmd/Data DDR3 BGA probe (W3631A)(Requires E5384A ZIF probe) E5845A ZIF probe) x8 Addr/Cmd/Data DDR2 BGA probe (W2633B)(Requires x8 Addr/Cmd/Data DDR3 BGA probe (W3633A) (Requires E5384A ZIF probe) E5847A ZIF probe) For higher speed memory analysis or greater channel count refer to the U4154A logic analyzer module. 1. Data pod is not connected for State measurements when used with the Series. Simultaneous State mode capture of Read and Write data requires a U4154A high-performance logic analyzer module with dual sample mode.
10 10 Keysight Series Portable Logic Analyzers - Data Sheet Validate your DDR2 and DDR3 Memory Systems (Continued) Series capture and decode of DDR3 Addr/Cmd lines Performance test analysis of DDR3 Addr/Cmd line saved trace Compliance test analysis of DDR3 Addr/Cmd line saved trace Figure 5. Multiple views for DDR2 and DDR3 Addr/Cmd capture.
11 11 Keysight Series Portable Logic Analyzers - Data Sheet Deep Memory Capture with 2.5 GHz (400 ps Eesolution) Timing Figure 6. Timing mode capture with 400 ps resolution and up to 128 M samples memory depth (example capture at 500 μs before trigger). Powerful, Customizable Triggering with a 1.4 GHz Sequencer Figure 7. Example of a time out trigger to capture an error condition.
12 12 Keysight Series Portable Logic Analyzers - Data Sheet Series Instrument Characteristics Standard data views Waveform Integrated display of data as digital waveforms, analog waveforms imported from an external oscilloscope, and/or as a chart of a bus values over time Listing Displays data as a state listing Compare Compares data from different acquisitions and highlights differences Source code Displays time-correlated source code and inverse assembly simultaneously in a split display Define the trigger event by simply clicking on a line of source code Obtain source-code-level views of dynamically loaded software or code moved from ROM to RAM during a boot-up sequence using address offsets Requires access to source files via the LAN or instrument hard drive to provide source code correlation Source correlation does not require any modification or recompilation of your source code Eye scan Displays eye diagrams across all buses and signals simultaneously, allowing you to identify problem signals quickly Data display Numeric bases for data display Binary, hex, octal, decimal, signed decimal (two s complement), ASCII, symbols, and processor mnemonics Symbolic support/object file format compatibility Number of symbols/ranges Unlimited (limited only by amount of virtual memory available on Series logic analyzers) Object file formats supported IEEE-695, Aout, Omf86, Omf96, Omf386, Sysrof, ELF/DWARF1 1, ELF/DWARF2 1, ELF/Stabs1, ELF/Stabs2, ELF/Mdebug Stabs, TICOFF/COFF, TICOFF/Stabs ASCII GPA (general purpose ASCII) User defined symbols Specify a mnemonic for a given bit pattern for a label or bus Available data/file formats ala Contains information to reconstruct the display appearance, instrument settings, and trace data (optional) that were present when the file was created xml Extensible markup language for configuration portability and programmability csv CSV (comma-separated values) format for transferring data to other applications like Microsoft Excel mfb Export logic analyzer data for post-processing. Mfb data can be parsed using programming tools Standard analysis tools Filter/colorize Show, hide, or color certain samples in a trace for easier identification and analysis Find (next/previous) Locate specific data in a captured trace
13 13 Keysight Series Portable Logic Analyzers - Data Sheet Series Instrument Characteristics (continued) Series PC characteristics Operating system Microsoft Windows 7 Embedded (64-bit) Processor Core 2 Duo, M890, 3.0 GHz microprocessor Chipset Intel Q45 System memory 4 GB Removable hard disk drive 500 GB Installed on hard drive Operating system, latest revision of the logic and protocol application software, optional application software ordered with the logic analyzer Series instrument controls LCD touch-screen display Large 38.1-cm (15-in.) touch-screen display makes is easy to view a large number of waveforms or states Front-panel hot keys Dedicated hot keys for selecting run mode and disabling touch screen Front-panel knob General-purpose knob adjusts viewing and measurement parameters Keyboard and mouse PS/2 keyboard and USB mouse Series video display modes Touch-screen display standard Size 38.1 cm (15 in.) diagonal Resolution 1024 x 768 External display Simultaneous display capability Front panel and external display can be used simultaneously at 1024 x 768 resolution Supports up to four external monitors at up to 1600 x 1200 (with PCI video card) Programmability You can write programs to control the logic analyzer application from remote computers on the local area network using COM or ASCII. The COM automation server is part of the logic analyzer application. This software allows you to write programs to control the logic analyzer. All measurement functionality is controllable via the COM interface. The B4608A Remote Programming Interface (RPI) lets you remotely control a Series logic analyzer by issuing ASCII commands to the TCP socket on port This interface is designed to be as similar as possible to the RPI on Series logic analysis systems, so that you can reuse existing programs. The remote programming interface works through the COM automation objects, methods, and properties provided for controlling the logic analyzer application. RPI commands are implemented as Visual Basic modules that execute COM automation commands, translate their results, and return proper values for the RPI. You can use the B4606A advanced customization environment to customize and add RPI commands. Computer with Windows XP or Windows 7 Distributed COM LAN connection Logic analyzer (16850/16800/16900) or PC running Keysight logic analyzer application Instrument COM automation server Figure Series programming overview.
14 14 Keysight Series Portable Logic Analyzers - Data Sheet Series Interfaces Peripheral interfaces Display One 15-pin XGA connector and one DVI connector Keyboard PS/2 Mouse PS/2 Serial 9-pin D-sub PCI card expansion slot 1 full profile Audio ports Line in, line out, mic in USB Six 2.0 ports, two in front, four in rear Connectivity interfaces LAN 10Base-T, 100Base-T, 1000Base-T Connector RJ-45 Interface with external instrumentation Trigger or arm external devices or receive signals that can be used to arm measurement hardware within the logic analyzer with Trigger In/Out Trigger in Input Rising edge or falling edge Action taken When received, the logic analyzer takes the actions described in the trigger sequence step Input signal level ± 5 V max Threshold level Selectable: ECL, LVPECL, LVTTL, PECL, TTL User defined (± 5 V in 50 mv increments) Minimum signal amplitude 200 mv Connector BNC Input resistance 4 kω nominal Trigger out Trigger Rising edge or falling edge. OR of selected events that cause Trigger Out (logic analyzer trigger or flags) Output signal VOH (output high level) 2.0 V min VOL (output low level) 0.5 V max Pulse width approx. 80 to 160 ns Threshold level LVTTL (3.3 V logic) Signal load 50 Ω (For good signal quality, the trigger out signal should be terminated in 50 Ω to ground) Connector BNC
15 15 Keysight Series Portable Logic Analyzers - Data Sheet Series Physical Characteristics Power 16851A 16852A 16853A 16854A 100 to 240V ± 10 %, 50/60Hz, 400 W max 100 to 240V ± 10 %, 50/60Hz, 400 W max 100 to 240V ± 10 %, 50/60Hz, 400 W max 100 to 240V ± 10 %, 50/60Hz, 400 W max Dimensions (11.53) Add 1.25 inches to the width to account for probes that plug into the right side of instrument (17.45) Note: 1. The mains supply voltage fluctuations are not to exceed ± 10 % of the nominal supply voltage. 2. Add 1.25 inches to the width to account for probes that plug into the right side of instrument. Dimensions: mm (in) Figure Series exterior dimensions (17.98) Weight Max net Max shipping 16851A 15.0 kg (33.0 lbs) 21.7 kg (48 lbs) 16852A 15.0 kg (33.0 lbs) 21.7 kg (48 lbs) 16853A 15.0 kg (33.0 lbs) 21.7 kg (48 lbs) 16854A 15.0 kg (33.0 lbs) 21.7 kg (48 lbs) 15 inch built-in color LCD display, touch screen standard AC power Mouse Keyboard Serial port Audio ports General purpose knob Run/stop keys On/Off power switch USB ports Touch screen on/off Trigger in Trigger out Clock in 10/100/1000 Base-T LAN 2.0 USB ports (4) External display ports Figure Series front and back panels. Instrument operating environment Temperature 5 C to 40 C (41 F to 104 F) Altitude To 2000 m (6,561 ft) Humidity Maximum 80% relative humidity, non-condensing Figure Series side view. Probe inputs Extra notes regarding the Series: 1. Pollution degree 2; 2. Installation category II; 3. These instruments are intended for use in an indoor lab environment
16 16 Keysight Series Portable Logic Analyzers - Data Sheet Ordering Information Each Series portable logic analyzer comes with one USB keyboard, one USB mouse, accessory pouch, power cord and 3-year warranty standard. Selecting a logic analyzer to meet your application and budget is as easy as 1, 2, 3. 1 Choose the channel count Model 16851A 16852A 16853A 16854A Channels Choose the state speed State speeds 350 MHz state clock; 700 Mbps data rate: Standard 700 MHz state clock; 1.4 Gbps data rate: < Model number > Choose the memory depth Memory depth (samples) 2 Mb: Standard 4 Mb: < Model number > Mb: < Model number > Mb: < Model number > Mb: < Model number > Mb: < Model number > Mb: < Model number > Series Probing Options Logic analyzer probes are ordered separately. Please specify probes when ordering to ensure the correct connection between your logic analyzer and the device under test Series logic analyzer probes General-purpose flying lead probes U4203A 34-ch single-ended data, differential clock, direct connect E5381B 17-ch differential probe for 90 pin LA pod 1, 2 E5382B 17-ch single-ended probe for 90 pin LA pod 1, 2 Connectorless probes U4204A Soft Touch Pro Series: 34-ch single-ended data, differential clock, direct connect E5387A Soft Touch Classic Series: 17-ch differential for 90 pin LA pod 1, 2 E5398A Half-Size Soft Touch: 17-ch single-ended for 90 pin LA pod 1, 2 E5390A Soft Touch Classic Series: 34-ch single-ended for 90 pin LA pod 1, 3 E5405B Soft Touch Pro Series: 17-ch differential for 90 pin LA pod 1, 2 E5406A Soft Touch Pro Series: 34-ch single-ended for 90 pin LA pod 1, 3 Connector probes U4201A 34-ch logic analyzer cable for use with E5xxxA 90-pin probes U4205A Mictor: 34-ch single-ended data and clock, direct connect E5378A Samtec: 34-ch single-ended probe for 90 pin LA pod 1, 3 E5379A Samtec: 17-ch differential probe for 90 pin LA pod 1, 2 E5380B Mictor: 34-ch single-ended probe for 90 pin LA pod 1, 2 1. Logic analyzer probe used with the U4201A logic analyzer cables channel probes require one of two 90 pin pods provided on the U4201A logic analyzer direct connect cable channel probes require both 90 pin pods provided on the U4201A logic analyzer cable.
17 17 Keysight Series Portable Logic Analyzers - Data Sheet Additional Series Options Keysight product or option number Description Ordering information E5864A Additional external hard drive (imaged with operating system and logic analyzer E5864A application software) After Purchase Options Upgrade memory depth or state speed after purchase Logic analyzer channels Logic analyzer models 16851A 16852A 16853A 16854A After purchase upgrade model numbers 16851AU 16852AU 16853AU 16854AU Memory depth (samples) 4 M: < Upgrade model number > M: < Upgrade model number > M: < Upgrade model number > M: < Upgrade model number > M: < Upgrade model number > M: < Upgrade model number > -128 State speed 700 MHz state clock/1400 Mbps state data rate: < Upgrade model number > 700 Related Literature Publication title Publication number Series Portable Logic Analyzers - Product Fact Sheet EN Series Logic Analysis Systems - Brochure EN Measurement Modules for the Series - Data sheet EN B4655A FPGA Dynamic Probe for Xilinx - Data Sheet EN Probing Solutions for Logic Analyzers - Data Sheet E
18 18 Keysight Series Portable Logic Analyzers - Data Sheet mykeysight A personalized view into the information most relevant to you. AdvancedTCA Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Keysight is a founding member of the AXIe consortium. ATCA, AdvancedTCA, and the ATCA logo are registered US trademarks of the PCI Industrial Computer Manufacturers Group. LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Keysight is a founding member of the LXI consortium. PCI extensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high-performance measurement and automation system. Three-Year Warranty Keysight s commitment to superior product quality and lower total cost of ownership. The only test and measurement company with three-year warranty standard on all instruments, worldwide. Keysight Assurance Plans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements. Keysight Technologies, Inc. DEKRA Certified ISO 9001:2008 Quality Management System Keysight Infoline Keysight s insight to best in class information management. Free access to your Keysight equipment company reports and e-library. Keysight Channel Partners Get the best of both worlds: Keysight s measurement expertise and product breadth, combined with channel partner convenience. For more information on Keysight Technologies products, applications or services, please contact your local Keysight office. The complete list is available at: Americas Canada (877) Brazil Mexico United States (800) Asia Pacific Australia China Hong Kong India Japan 0120 (421) 345 Korea Malaysia Singapore Taiwan Other AP Countries (65) Europe & Middle East Austria Belgium Finland France Germany Ireland Israel Italy Luxembourg Netherlands Russia Spain Sweden Switzerland Opt. 1 (DE) Opt. 2 (FR) Opt. 3 (IT) United Kingdom For other unlisted countries: (BP ) This information is subject to change without notice. Keysight Technologies, Published in USA, May 20, EN
What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?
What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope? Application Note In the past, deciding between an equivalent time sampling oscilloscope and a real
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide
Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors Demo Guide Introduction This demonstration guide helps you to get familiar with the basic setup and coniguration requirements
Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide
Keysight M9485A PXIe Multiport Vector Network Analyzer Configuration Guide 02 Keysight M9485A PXIe Multiport Vector Network Analyzer - Configuration Guide Ordering Guide The following steps will guide
U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes
U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes Data Sheet This application is available in the following license variations Order N7248A for user-installed license
Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note
Keysight Technologies Using Fine Resolution to Improve Thermal Images Application Note Introduction Digital imaging opened up new possibilities and has been very much part of our lives since social media
Agilent E5063A ENA Series Network Analyzer
Agilent E5063A ENA Series Network Analyzer 100 khz to 4.5/ 8.5/18 GHz Configuration Guide Ordering Guide The following steps will guide you through configuring your E5063A. Standard furnished item Description
Agilent E363xA Series Programmable DC Power Supplies. Data Sheet
Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation
Keysight E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software
Keysight E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software For Infiniium Oscilloscopes Data Sheet 02 Keysight E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery
How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer
How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer Application Note Introduction In a pulsed radar system, one of the key transmitter-side components
Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet
Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet Use BenchVue software to: Visualize multiple measurements simultaneously Easily capture data, screen shots and
N5416A and N5417A USB Compliance Test Software for Infiniium Oscilloscopes
N546A and N547A USB Compliance Test Software for Infiniium Oscilloscopes Data Sheet The N546A USB compliance test software for Infiniium oscilloscopes gives you a fast and reliable way to verify USB electrical
High-Speed Inter Connect (HSIC) Solution
High-Speed Inter Connect (HSIC) Solution HSIC Essentials Datasheet Protocol Decode Protocol decode Saves test time and resource costs. Designed for use with the MSO/DPO5000, DPO7000C, DPO/DSA/MSO70000C,
Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network
Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network Application Brief Test Challenges: Designing heating and air conditioning (HVAC) systems Collecting data on a remotely located
Keysight Technologies N9320B RF Spectrum Analyzer
Keysight Technologies N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet Definitions and Conditions The spectrum analyzer will meet its specifications when: It is within its calibration cycle It has
The Next Generation in Automated Oscilloscope Test
The Next Generation in Automated Oscilloscope Test Spanning 100 MHz to 13 GHz, and varying in height from 1U to 8U, Agilent s family of LXI compliant oscilloscopes can accommodate virtually any automated
Keysight N9320B RF Spectrum Analyzer
Keysight N9320B RF Spectrum Analyzer 9 khz to 3.0 GHz Data Sheet 02 Keysight N9320B RF Spectrum Analyzer - Data Sheet Definitions and Conditions Specifications describe the performance of parameters covered
How To Use A High Definition Oscilloscope
PRELIMINARY High Definition Oscilloscopes HDO4000 and HDO6000 Key Features 12-bit ADC resolution, up to 15-bit with enhanced resolution 200 MHz, 350 MHz, 500 MHz, 1 GHz bandwidths Long Memory up to 250
Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family
Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family Product Overview Requires an Agilent 16700A/B Series or 16900A Series Logic Analysis System The Agilent E8047B analysis
Make Better RMS Measurements with Your DMM
Make Better RMS Measurements with Your DMM Application Note Introduction If you use a digital multimeter (DMM) for AC voltage measurements, it is important to know if your meter is giving you peak value,
802.11ac Power Measurement and Timing Analysis
802.11ac Power Measurement and Timing Analysis Using the 8990B Peak Power Analyzer Application Note Introduction There are a number of challenges to anticipate when testing WLAN 802.11ac [1] power amplifier
DDR Memory Overview, Development Cycle, and Challenges
DDR Memory Overview, Development Cycle, and Challenges Tutorial DDR Overview Memory is everywhere not just in servers, workstations and desktops, but also embedded in consumer electronics, automobiles
TekSmartLab TBX3000A, TSL3000B Datasheet
TekSmartLab TBX3000A, TSL3000B Datasheet TekSmartLab is the industry's first network-based instrument management solution for teaching labs that brings a more efficient lab experience. With the TekSmartLab,
Keysight N6854A Geolocation System. Configuration Guide
Keysight N6854A Geolocation System Configuration Guide 02 Keysight N6854A Geolocation System - Configuration Guide This guide will help you configure a geolocation system that meets your needs and includes
Evaluating Oscilloscope Bandwidths for Your Application
Evaluating Oscilloscope Bandwidths for Your Application Application Note Table of Contents Introduction....1 Defining Oscilloscope Bandwidth.....2 Required Bandwidth for Digital Applications...4 Digital
Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software
Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software Technical Brief Introduction The MSO70000 Series Mixed Oscilloscope, when coupled with SignalVu Spectrum
Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes
Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes Data Sheet Enhance your InfiniiVision or Infiniium oscilloscope with the analysis power of MATLAB software Develop custom analysis
Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance
Keysight Technologies Long-Term, Remote Monitoring of Satellite Performance Using a Keysight High-Frequency USB Power Sensor Application Note 1.0 Introduction Satellite communication systems are driven
PCI Express 1.0 (2.5 GT/s) Protocol Test
PCI Express 1.0 (2.5 GT/s) Protocol Test Configuration and Pricing Guide Gen1 today, ready for Gen2 in the future As PCI Express Gen2 becomes more mature in the market, you must decide whether to continue
X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software
X-Series Signal Analysis Future-ready instruments Consistent measurement framework Broadest set of applications and software Arrive Ahead with X-Series We can t predict the future, but Agilent can help
TekConnect Adapters. TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet. Applications. Features & Benefits
TekConnect Adapters TCA75 TCA-BNC TCA-SMA TCA-N TCA-292MM Data Sheet TCA-N TekConnect-to-N DC to 11 GHz (Instrument Dependent) 50 Ω Input (Only) TCA-SMA TekConnect-to-SMA DC to 18 GHz (Instrument Dependent)
Agilent 4339B/4349B High Resistance Meters
Agilent 4339B/4349B High Resistance Meters Technical Overview Within Budget Without Compromise Introducing the Agilent Technologies 4339B and 4349B High Resistance Meters Used for Making Ultra- High Resistance
PCI Express Probes for Agilent E2960B PCI Express Analysis Systems
PCI Express for Agilent E2960B PCI Express Analysis Systems Version: 1.2 Superior Signal Probing options to address diverse designs and form factors As an industry leader in the innovation of non-intrusive,
Agilent 87421A/87422A Power Supply
Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration
Chapter 5 Cubix XP4 Blade Server
Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel
Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range. Application Note
Keysight Technologies Understanding and Improving Network Analyzer Dynamic Range Application Note Introduction Achieving the highest possible network analyzer dynamic range is extremely important when
An Overview of the Electrical Validation of 10BASE-T, 100BASE-TX, and 1000BASE-T Devices
An Overview of the Electrical Validation of 10BASE-T, 100BASE-TX, and 1000BASE-T Devices Application Note The number of devices that come with a built-in network interface card has risen steadily and will
PXI and AXIe Modular Instrumentation
PXI and AXIe Modular Instrumentation M9018A PXIe Chassis M9502A AXIe Chassis M9505A AXIe Chassis Tested Computer List Technical Note DISCOVER the Alternatives...... Agilent MODULAR Products OVERVIEW This
PXI and AXIe Modular Instrumentation
PXI and AXIe Modular Instrumentation M9018A PXIe Chassis M9502A AXIe Chassis M9505A AXIe Chassis U4002A Digital Test Console Chassis Tested Computer List Technical Note DISCOVER the Alternatives......
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors Configuration Guide U2000 Series USB Power Sensors U2000A (10 MHz to 18 GHz) U2001A (10 MHz to 6 GHz) U2002A (50 MHz to 24 GHz) U2004A (9 khz to 6 GHz) U2000H (10
Agilent U4301A PCI Express 3.0 Analyzer Module. Data Sheet. Agilent solutions for PCIe Gen1 to Gen3 analysis and emulation.
Agilent U4301A PCI Express 3.0 Analyzer Module Data Sheet Agilent solutions for PCIe Gen1 to Gen3 analysis and emulation. PCI Express generation 1, 2, & 3 protocol architecture Lane speeds 2.5 GT/s, 5.0
Agilent 4338B Milliohm Meter
Agilent 4338B Milliohm Meter 10 µω to 100 kω Technical Overview Introduction Ideal for precise measurements of extremely low resistances using an ac test signal, the Agilent Technologies 4338B suits bench-top
Keysight E5063A ENA Series PCB Analyzer
Keysight E5063A ENA Series PCB Analyzer Technical Overview The Best Solution for PCB Manufacturing Test More accuracy and R&R More languages supported More ESD robustness Why choose the E5063A PCB Analyzer
Agilent 16900 Series Logic Analysis System Mainframes
Agilent 16900 Series Logic Analysis System Mainframes Data Sheet Conquer your toughest digital debug problems while staying within your budget The Agilent 16900 Series modular logic analysis mainframes
Keysight Technologies The Advantages Of Remote Labs In Engineering Education
Keysight Technologies The Advantages Of Remote Labs In Engineering Education Application Note Educator s Corner Introduction The widespread availability of local area networks (LAN) and web access has
R&S ZNC Vector Network Analyzer Specifications
ZNC3_dat-sw_en_5214-5610-22_v0300_cover.indd 1 Data Sheet 03.00 Test & Measurement R&S ZNC Vector Network Analyzer Specifications 04.09.2012 13:39:47 CONTENTS Definitions... 3 Measurement range... 4 Measurement
Agilent N5970A Interactive Functional Test Software: Installation and Getting Started
Agilent N5970A Interactive Functional Test Software: Installation and Getting Started Application Note The N5970A Interactive Functional Test Software along with the 8960 Series 10 (E5515C) wireless communications
Agilent Television Power Consumption Testing. Application Note
Agilent Television Power Consumption Testing Application Note Introduction Today, there are many types of televisions (TVs) on the market: the cathode ray tube (CRT) TV, liquid crystal display (LCD) TV,
Keysight Technologies 8 Hints for Better Spectrum Analysis. Application Note
Keysight Technologies 8 Hints for Better Spectrum Analysis Application Note The Spectrum Analyzer The spectrum analyzer, like an oscilloscope, is a basic tool used for observing signals. Where the oscilloscope
Variable Frequency Drive Troubleshooting with U1610A/U1620A
Variable Frequency Drive Troubleshooting with U1610A/U1620A Application Note Electric motors form the backbone of most industrial and manufacturing environments. Variable frequency drives (VFDs) (also
TrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
DCS Data and communication server
8 58 PLD.TOWER PLD.RACK VISONIK DCS Data and communication server PLD.TOWER PLD.RACK Data and communication servers (DCS) are used as management stations in building automation and control (BAC). With
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors GSM Timeslot Burst Power Measurement Product Note Table of Content Introduction 2 Measuring GSM Timeslot 4 Signal Overview of Agilent U2000 5 Series USB Power Sensors
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet
Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers Data Sheet Specifications Specifications are only valid for the stated operating frequency, and apply over 0 C to +55 C unless otherwise
DDR3 DIMM Slot Interposer
DDR3 DIMM Slot Interposer DDR3-1867 Digital Validation High Speed DDR3 Digital Validation Passive 240-pin DIMM Slot Interposer Custom Designed for Agilent Logic Analyzers Compatible with Agilent Software
R&S ZNBT8 Vector Network Analyzer Specifications
ZNBT8_dat-sw_en_3606-9727-22_v0200_cover.indd 1 Data Sheet 02.00 Test & Measurement R&S ZNBT8 Vector Network Analyzer Specifications 20.05.2014 08:39:42 CONTENTS Definitions... 3 Measurement range... 4
Description: Multiparameter System (4 or 8 channels)
Model MPA4, 8 ch acquisition system with 6 ns time tagging The MPA4 is a Multiparameter Data Acquisition System Description: Multiparameter System (4 or 8 channels) ADC Settings and Presets Dialog The
Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note
Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments Application Note Table of Contents Introduction 2 U2000 Series USB Power 3 Sensor s Compatibility with Agilent Instruments
Agilent FieldFox Remote Viewer
Agilent FieldFox Remote Viewer Application Brief Agilent Remote Viewer setup instructions The FieldFox remove viewer is a FREE ios application which allows you to view an Agilent FieldFox analyzer from
PCI Express Transmitter Electrical Validation and Compliance Testing with Agilent Infiniium Oscilloscopes
PCI Express Transmitter Electrical Validation and Compliance Testing with Agilent Infiniium Oscilloscopes Application Note 1496 Who should read this application note? This application note is intended
USB 3.0 to HDMI External Multi Monitor Graphics Adapter with 3-Port USB Hub HDMI and USB 3.0 Mini Dock 1920x1200 / 1080p
USB 3.0 to HDMI External Multi Monitor Graphics Adapter with 3-Port USB Hub HDMI and USB 3.0 Mini Dock 1920x1200 / 1080p StarTech ID: USB32HDEH3 The USB32HDEH3 USB 3.0 to HDMI Adapter turns a USB 3.0 port
Trace Port Analysis for ARM7-ETM and ARM9-ETM Microprocessors
Trace Port Analysis for ARM7-ETM and ARM9-ETM Microprocessors Product Overview Introduction Quickly and accurately determine the root cause of your team s most difficult hardware, software, and system
Agilent Automotive Power Window Regulator Testing. Application Note
Agilent Automotive Power Window Regulator Testing Application Note Abstract Automotive power window regulator tests require the use of accurate data acquisition devices, as they cover a wide range of parameters
1.5 GHz Active Probe TAP1500 Datasheet
1.5 GHz Active Probe TAP1500 Datasheet Easy to use Connects directly to oscilloscopes with the TekVPI probe interface Provides automatic units scaling and readout on the oscilloscope display Easy access
Cisco MCS 7816-I3 Unified Communications Manager Appliance
Cisco MCS 7816-I3 Unified Communications Manager Appliance Cisco Unified Communications is a comprehensive IP communications system of voice, video, data, and mobility products and applications. It enables
Keysight Technologies Solutions for WLAN 802.11ac Manufacturing Test
Keysight Technologies Solutions for WLAN 802.11ac Manufacturing Test Application Note Testing 802.11ac Client and Infrastructure Devices Using a Fast, Flexible and Cost-Effective Calibration and Non-Signaling
USB 3.0 to VGA External Multi Monitor Graphics Adapter with 3-Port USB Hub VGA and USB 3.0 Mini Dock 1920x1200 / 1080p
USB 3.0 to VGA External Multi Monitor Graphics Adapter with 3-Port USB Hub VGA and USB 3.0 Mini Dock 1920x1200 / 1080p StarTech ID: USB32VGAEH3 The USB32VGAEH3 USB 3.0 to VGA Adapter turns a USB 3.0 port
Highly Scalable Server for Many Possible Uses. MAXDATA PLATINUM Server 3200 I
Highly Scalable Server for Many Possible Uses MAXDATA PLATINUM Server 3200 I MAXDATA PLATINUM Server 3200 I: Highly Scalable Server for Many Possible Uses Standard Features Now more than ever, profitable
Chapter 6. Inside the System Unit. What You Will Learn... Computers Are Your Future. What You Will Learn... Describing Hardware Performance
What You Will Learn... Computers Are Your Future Chapter 6 Understand how computers represent data Understand the measurements used to describe data transfer rates and data storage capacity List the components
Agilent U2000 Series USB Power Sensors
Agilent U2000 Series USB Power Sensors Single/Multi-Channel Power Measurement Simple Setup Affordable Demo Guide Table of Contents Introduction 2 The Agilent N1918A Power 3 Analysis Manager Demonstration
Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator
Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator Application Note 1 Summary Introduction As a part of the certification
QuickSpecs. HP IP Console Switch with Virtual Media Overview
Overview HP's IP Console Switch with Virtual Media is a key component in managing the heterogeneous data center and along with the IP Viewer software allows remote access to multiple servers running various
ROSA Server MKVI. A Complete, Powerful Solution
Cisco ROSA Server MKVI Description Working in harmony with the Cisco ROSA management software, the ROSA Server provides the user with outstanding reliability and flexibility. Together, ROSA Server MKVI
Release Notes: PowerChute plus for Windows 95 and Windows 98
: PowerChute plus for Windows 95 and Windows 98 These release notes supplement the User s Guide: PowerChute plus, Version 5.0.2, for Windows 95 and Windows 98 (pc98ug.pdf) and the Installation Guide: PowerChute
Agilent Technologies 3000 Series Oscilloscopes
Agilent Technologies 3000 Series Oscilloscopes Data Sheet The performance and features you need at the industry s lowest price Features: 60 to 200 MHz bandwidths 1 GSa/s maximum sample rate Large 15-cm
Agilent VEE Pro 9.32. Data Sheet
Agilent VEE Pro 9.32 Data Sheet Agilent VEE 9.32 Features New sample programs for Agilent 33500 series function/arbitrary waveform generator, 34411A digital multimeter and DSO/MSO oscilloscopes. General
N6171A MATLAB Data Analysis Software for Agilent Instruments
N6171A MATLAB Data Analysis Software for Agilent Instruments Technical Overview MATLAB is available directly from Agilent or its authorized sales partners with your instrument purchase Use MATLAB to create
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
WD Hard Drive Interface Guide
Hard Drive Interface Guide WD Hard Drive Interface Guide WD Service and Support Should you encounter any problem, please give us an opportunity to address it before returning this product. Most technical
Making Basic Measurements. Publication Number 16700-97020 August 2001. Training Kit for the Agilent Technologies 16700-Series Logic Analysis System
Making Basic Measurements Publication Number 16700-97020 August 2001 Training Kit for the Agilent Technologies 16700-Series Logic Analysis System Making Basic Measurements: a self-paced training guide
AXIS 262+ Network Video Recorder
31433/EN/R4/0803 Complete Network Video Recording Solution Complete Network Video Recording Solution Picture this: A simple and reliable, plug-and-play video surveillance system for hotels, shops, banks,
Waveform Monitor Audio & Loudness Logging
Waveform Monitor Audio & Loudness Logging PT0800M Data sheet Nov. 201 3 V.1.0 Introducing the PT0800M The PT0800 introduces a unique combination of Audio, Loudness and Waveform monitoring at the highest
A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware
A+ Guide to Managing and Maintaining Your PC, 7e Chapter 1 Introducing Hardware Objectives Learn that a computer requires both hardware and software to work Learn about the many different hardware components
Specifications for the Gateway M1300 Tablet PC
Specifications for the Gateway M1300 Tablet PC Specifications are subject to change without notice or obligation. Processor and Core Logic Processor options Chipset Processor packaging Level 2 cache Core
Executive Series. Intel Desktop Board DB75EN Executive Series MicroATX Form Factor
Intel Desktop Board DB75EN MicroATX Form Factor product brief Built for Business: Intel Desktop Board DB75EN maximizes employee productivity, PC performance, and data security with Intel Small Business
Free 15-day trial. Signata Waveform Viewer Datasheet
The Signata Waveform Viewer allows you to view and analyze data captured from your oscilloscope anytime and anywhere. You will gain instant insight into device performance, quickly determine the root cause
NETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
QuickSpecs. Models HP Server Console Switches
Overview are key components for rack mount implementations (a console represents one keyboard, video monitor, and mouse (KVM) attached to a server). The family of allows multiple servers in a rack to be
Impedance 50 (75 connectors via adapters)
VECTOR NETWORK ANALYZER PLANAR TR1300/1 DATA SHEET Frequency range: 300 khz to 1.3 GHz Measured parameters: S11, S21 Dynamic range of transmission measurement magnitude: 130 db Measurement time per point:
Cisco 7816-I5 Media Convergence Server
Cisco 7816-I5 Media Convergence Server Cisco Unified Communications Solutions unify voice, video, data, and mobile applications on fixed and mobile networks, enabling easy collaboration every time from
Scout 1U Rackmount Computer
Model Numbers ACC-CPU-RM- WIN7x64 ACC-CPU-RM-2008 Revision 5 Scout 1U Rackmount Computer Introduction The Scout 1U Rackmount Computer includes a solid state hard drive loaded with the Microsoft Windows
Interface Adapters PS/2 Interface Adapter 1 pack 262588-B21 PS/2 Interface Adapter 8 pack 262587-B21 USB Interface Adapter 1 pack 336047-B21
Overview Models HP Server Console Switches 1X8-Port KVM 336044-B21 2X16-Port KVM 336045-B21 CAT5e Cables 3 Foot (1 m) 4 pack 263474-B21 6 Foot (2 m) 8 pack 263474-B22 12 Foot (4 m) 8 pack 263474-B23 20
zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s
TECHNICAL SPECIFICATIONS zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s 2015 LitePoint, A Teradyne Company. All rights reserved. The LitePoint zseries 18-slot chassis is an
System Configuration and Order-information Guide ECONEL 100 S2. March 2009
System Configuration and Orderinformation Guide ECONEL 100 S2 March 2009 Front View DVDROM Drive 5 inch Bay Floppy Disk Drive Back View Mouse Keyboard Serial Port Display 10/100/1000BASET Connector Inside
Application Server V240 Platform
Application Server V240 Platform The V240 Application Server (V240) features four hot-swappable disks with redundant power supplies for reliable system performance. The server also has three PCI slots
11. High-Speed Differential Interfaces in Cyclone II Devices
11. High-Speed Differential Interfaces in Cyclone II Devices CII51011-2.2 Introduction From high-speed backplane applications to high-end switch boxes, low-voltage differential signaling (LVDS) is the
Agilent E5061B Network Analyzer. 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz
Agilent E5061B Network Analyzer 100 khz to 1.5 GHz/3 GHz 5 Hz to 3 GHz E5061B responds to various measurement needs, from LF to RF The Agilent E5061B is a member of the industry standard ENA Series network
High speed pattern streaming system based on AXIe s PCIe connectivity and synchronization mechanism
High speed pattern streaming system based on AXIe s connectivity and synchronization mechanism By Hank Lin, Product Manager of ADLINK Technology, Inc. E-Beam (Electron Beam) lithography is a next-generation
Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz
Agilent E5063A ENA Series Network Analyzer 100 khz to 4.5/ 8.5/18 GHz The Best Balance Between Price and Performance The E5063A is a low cost network analyzer for simple passive component testing up to
SNC-VL10P Video Network Camera
SNC-VL10P Video Network Camera CHANGING THE WAY BUSINESS 2AM. WATCHING HIS NEW PRODUCTION LINE. 10,000 MILES AWAY. COMMUNICATES www.sonybiz.net/netstation CORPORATE COMMUNICATIONS SURVEILLANCE VIDEOCONFERENCING