POSITIVE INPUT VENTILATION 129
|
|
|
- Georgiana Young
- 10 years ago
- Views:
Transcription
1 POSTVE NPUT VENTLATON 129 FAN TYPE FAN LOCATON MAX PAGE PERFORMANCE DRMASTER LOFT 10-70l/s 130 DRMASTER 2000 LOFT 10-70l/s 134 DRMASTER 365 LOFT 10-70l/s 138 DRMASTER HEAT LOFT 10-70l/s 142 FLATMASTER WALL 15-22l/s 148 FLATMASTER 2000 WALL 15-35l/s 152 nuaire.co.uk 129
2 DRMASTER DRMASTER - POSTVE NPUT VENTLATON (PV) LOW COST WHOLE HOUSE VENTLATON THAT MEETS BULDNG REGULATONS, SAVES ENERGY AND PREVENTS CONDENSATON
3 DRMASTER BENEFTS EXTREMELY LOW POWER CONSUMPTON Average approximately 0.16 watts / litre / second and solar gains up to 550kW / hr / year. EASY NSTALLATON & VERY LOW MANTENANCE REQUREMENT Filter clean or replacement every 5 years. RADON GAS CONTROL Helps reduce and maintain radon gas levels. CREATES A HEALTHER LVNG ENVRONMENT High efficiency G4 filters removes up to 95% dust particles. HEALTH Clinically proven to help allergy and asthma sufferers. WARRANTY 5 year warranty for peace of mind. SGNFCANTLY MPROVES NDOOR AR QUALTY Using positive input ventilation removes indoor air pollutants such as carbon monoxide and keeps out traffic fumes, pollen and outdoor pollutants. COMPLES WTH THE BULDNG REGULATON VENTLATON REQUREMENTS Meets Part F&L England and Wales and contributes towards conservation of fuel and power. (Please refer to BBA Certificate). FT & FORGET OPERATON Fully automatic when airflow set on installation. FRE DAMPER AND DFFUSER FOR 3-STOREY ACCOMMODATON AVALABLE The diffuser is manufactured from aluminium and powder coated to an off white finish (RAL 9003). Product code Drimaster-3S. SYSTEM STANDBY MODE For summer months when loft temperature exceeds 23ºC. TYPCAL NSTALLATON Ceiling diffuser. Download specification from nuaire.co.uk 131
4 DRMASTER DRMASTER The Drimaster provides whole home ventilation using the Positive nput Ventilation principle. Essentially the concept is to introduce fresh, filtered air into the dwelling at a continuous rate, encouraging movement of air from inside to outside. To achieve this, the unit is mounted in the loft space, drawing air through the filters and inputting it, at ceiling level, into the property. The Drimaster units are fitted with an internal temperature sensor. This sensor continuously monitors the temperature in the loft, boosting the air volume when the loft temperature is above a set level (heat recovery mode). f the loft temperature becomes excessive the unit will switch to standby mode (no airflow). Once installed, the airflow can be set to suit the house size and, if required, the way it responds to the temperature changes within. WRNG The unit is supplied with a pre-wired power supply. This power supply unit has a metal bracket incorporating fixing holes, which should be used to fit the power supply to a suitable surface e.g. a wooden joist. The fan unit is also supplied with a fused spur. The 3 core mains cable from the power supply should be connected to a fixed wiring installation, via the isolator, via the spur, in accordance with current EE wiring regulations. Electrical details:- Voltage: 240V 1ph 50Hz Consumption: 1.6W(min) 15.3W(max) Fuse size: 1 Amp AR DFFUSER WTH FRE DAMPER For use in stairwells of three storey properties, the optional powder-coated aluminium diffuser with Fireblock provides 1 hour of fire resistance in accordance with BS476 Part 20 and SO834. Ceiling Hole in ceiling 200mm dia. Studs Diffuser supplied (A) (B) 4 x MSx35mm screws (C) Spacers dia. Fixing (C) to (B) 303 DMENSONS (MM) & WEGHT DRMASTER UNT Weight: 5.7kg Flexible ducting dia. Filter Filter
5 DRMASTER CONSULTANTS SPECFCATON FAN DESCRPTON Low energy positive input ventilation unit - for use in homes with a loft. The unit shall be robustly constructed from flame retardant VO rated ABS polymer and the casing shall be of spherical pattern with a flat mounting base. Flame retardant filters of G4 grade, surface area approx 0.47m 2 (with 5 year typical maintenance period) shall be fitted, which may be removed from the unit without the use of tools. The filters shall be arranged such as to prevent their obstruction in the loft space. The unit shall incorporate a forward curved centrifugal impeller and high efficiency brushless DC motor fitted with sealed for life, self lubricating bearings and locked rotor protection. The unit s average power consumption shall be 0.16 watts per l/s of airflow. The unit shall be supplied with a length of flexible ducting, and all necessary connectors and fixings. The unit shall weigh less than 6kg and we recommend that the unit is suspended from the roof structure. The unit shall be supplied with a purpose designed flame retardant polymer diffuser for efficient, directable air input.the diffuser design shall be optimised for use in areas where smoke detectors are fitted. The unit shall include 5 programmable temperature control strategies, 6 volume control settings and an optional high duty boost setting providing an airflow rate of 70l/s for optimum performance and occupant comfort. The units Fixed Temperature Heat Recovery strategy shall be achieved via a sensor located in the unit and shall improve energy performance accordingly. An internal monitor shall record the unit s operational time. The unit shall be offered with a 5 year warranty. For information on reducing radon egress, it is suggested that the details given in Positive pressurisation: a guide to radon remedial measures in existing dwellings may be considered. Download specification from nuaire.co.uk 133
6 DRMASTER 2000 DRMASTER POSTVE NPUT VENTLATON (PV) LOW COST WHOLE HOUSE VENTLATON WTH NTELLGENT HEAT RECOVERY THAT MEETS BULDNG REGULATONS, SAVES ENERGY AND PREVENTS CONDENSATON. Sensor/ndicator
7 DRMASTER 2000 BENEFTS EXTREMELY LOW POWER CONSUMPTON Average approximately 0.16 watts / litre / second and solar gains up to 550kW / hr / year. EASY NSTALLATON & VERY LOW MANTENANCE REQUREMENT Filter clean or replacement every 5 years. SGNFCANTLY MPROVES NDOOR AR QUALTY Using positive input ventilation removes indoor air pollutants such as carbon monoxide and keeps out traffic fumes, pollen and outdoor pollutants. NTELLGENT HEAT RECOVERY Twin sensors optimise energy efficiency, adjusting settings to provide increased comfort. COMPLES WTH THE BULDNG REGULATON VENTLATON REQUREMENTS Meets Part F&L England and Wales and contributes towards conservation of fuel and power. (Please refer to BBA Certificate). CREATES A HEALTHER LVNG ENVRONMENT High efficiency G4 filters removes up to 95% dust particles. FT & FORGET OPERATON Fully automatic when airflow set on installation. FRE DAMPER AND DFFUSER FOR 3-STOREY ACCOMMODATON AVALABLE The diffuser is manufactured from aluminium and powder coated to an off white finish (RAL 9003). Product code Drimaster-3S. SYSTEM STANDBY MODE For summer months when loft temperature exceeds 23ºC. HEALTH Clinically proven to help allergy and asthma sufferers. OPTONAL BOOST FACLTY When additional ventilation is required i.e. cooking odours etc. WARRANTY 5 year warranty for peace of mind. NSTALLATON OPTONS Ceiling diffuser. Roof structure Standard method of fixing. Optional method of fixing. (AV mounting kit onto roof joists). Download specification from nuaire.co.uk 135
8 DRMASTER 2000 DRMASTER 2000 The Drimaster 2000 provides whole home ventilation using the Positive nput Ventilation principle. Essentially the concept is to introduce fresh, filtered air into the dwelling at a continuous rate, encouraging movement of air from inside to outside. To achieve this, the unit is mounted in the loft space, drawing air through the filters and inputting it, at ceiling level, into the property. Siting the Remote Sensor The Remote Temperature Sensor incorporates a clip-in fixing bracket which can be removed for easy fitting to a suitable surface. Select a suitable location for the sensor e.g. close to ceiling height in a bedroom or hallway BUT NOT WTHN 3 METRES of the diffuser. AR DFFUSER WTH FRE DAMPER For use in stairwells of three storey properties, the optional powder-coated aluminium diffuser with Fireblock provides 1 hour of fire resistance in accordance with BS476 Part 20 and SO834. WRNG The unit is supplied with a pre-wired power supply. This power supply unit has a metal bracket incorporating fixing holes, which should be used to fit the power supply to a suitable surface e.g. a wooden joist. The fan unit is also supplied with a fused spur. The two core mains cable from the power supply should be connected to a fixed wiring installation, via the isolator, via the spur, in accordance with current EE wiring regulations. Optional BOOST facility The unit air volume can be manually boosted to maximum speed by wiring in a simple one way switch (Part No ) into the wire supplying the sensor. By switching the unit to BOOST all other functions are over-ridden. Electrical details:- Voltage: 240V 1ph 50Hz Consumption: 1.6W(min) 15.3W(max) Fuse size: 1 Amp Ceiling (A) Hole in ceiling 200mm dia. Studs Diffuser supplied (B) 4 x MSx35mm screws (C) Spacers Fixing (C) to (B) dia. DMENSONS (MM) & WEGHT DRMASTER 2000 UNT Weight: 5.7kg Flexible ducting dia. Filter Filter
9 DRMASTER 2000 CONSULTANTS SPECFCATON FAN DESCRPTON Low energy positive input ventilation unit - for use in homes with a loft. The unit shall be robustly constructed from flame retardant VO rated ABS polymer and the casing shall be of spherical pattern with a flat mounting base. Flame retardant filters of G4 grade, surface area approx 0.47m 2 (with 5 year typical maintenance period) shall be fitted, which may be removed from the unit without the use of tools. The filters shall be arranged such as to prevent their obstruction in the loft space. The unit shall incorporate a forward curved centrifugal impeller and high efficiency brushless DC motor fitted with sealed for life, self lubricating bearings and locked rotor protection. The unit s average power consumption shall be 0.16 watts per l/s of airflow. The unit shall be supplied with a length of flexible ducting, and all necessary connectors and fixings. The unit shall weigh less than 6kg and we recommend that the unit is suspended from the ceiling. The unit shall be supplied with a purpose designed flame retardant polymer diffuser for efficient, directable air input.the diffuser design shall be optimised for use in areas where smoke detectors are fitted. The unit shall include 5 programmable temperature control strategies, 6 volume control settings and an optional high duty boost setting providing an airflow rate of 70 l/s for optimum performance and occupant comfort. All control/duty strategies shall be optimised for maximum occupant comfort. The unit s ntelligent Heat Recovery shall be achieved via twin temperature sensors; one sensor integral to the unit to monitor loft temperatures and one sensor located in the living space. The twin sensors shall optimise energy performance accordingly. The sensor located in the living space shall also be capable of providing unit/filter status indication. An internal monitor shall record the unit s operational time. The unit shall be offered with a 5 year warranty. For information on reducing radon egress, it is suggested that the details given in Positive pressurisation: a guide to radon remedial measures in existing dwellings may be considered. Download specification from nuaire.co.uk 137
10 DRMASTER 365 DRMASTER POSTVE NPUT VENTLATON (PV) A UNQUE, LOW ENERGY, ALL YEAR ROUND VENTLATON UNT
11 DRMASTER 365 BENEFTS EXTREMELY LOW POWER CONSUMPTON Average approximately 0.16 watts / litre / second and solar gains up to 550kW / hr / year. EASY NSTALLATON & VERY LOW MANTENANCE REQUREMENT Filter clean or replacement every 5 years. RADON GAS CONTROL Helps reduce and maintain radon gas levels. CREATES A HEALTHER LVNG ENVRONMENT High efficiency G4 filters removes up to 95% dust particles. SECURTY Allows occupants to keep windows closed for added security and reduce noise levels. OPTONAL BOOST FACLTY When additional ventilation is required i.e. cooking odours etc. SGNFCANTLY MPROVES NDOOR AR QUALTY Using positive input ventilation removes inddor air pollutants such as carbon monoxide and keeps out traffic fumes, pollen and outdoor pollutants. NTELLGENT HEAT RECOVERY Twin sensors optimise energy efficiency, adjusting settings to provide increased comfort. COMPLES WTH THE BULDNG REGULATON VENTLATON REQUREMENTS Meets Part F&L England and Wales and contributes towards conservation of fuel and power. (Please refer to BBA Certificate). FT & FORGET OPERATON Fully automatic when airflow set on installation. FRE DAMPER AND DFFUSER FOR 3-STOREY ACCOMMODATON AVALABLE The diffuser is manufactured from aluminium and powder coated to an off white finish (RAL 9003). Product code Drimaster-3S. HEALTH Clinically proven to help allergy and asthma sufferers. OPTONAL HEATER FACLTY To provide additional heat to the incoming air if required i.e. during very cold weather. WARRANTY 5 year warranty for peace of mind. ECODR Heater. Control interface Drimaster365 Air from loft 150mm dia. flexible ducting Setting switch is located on the rear of the fan case. Air from outside 200mm dia. flexible ducting Remote Sensor. G4 Filter. Diffuser Unit mounted on roof joists using two L shape metal brackets and AV mounts supplied with unit. Boost Switch. Ceiling Diffuser. Download specification from nuaire.co.uk 139
12 DRMASTER 365 DRMASTER365 Drimaster365 is a unique low energy, loft mounted Positive nput Ventilation unit providing whole home ventilation all year round. The unit is totally automatic and intelligently decides what location to supply the air from. t utilises the solar gain within the loft during the colder months subsequently, overcomes excessive solar gains during the warmer months. WRNG Please note: the electrical connection of the unit must be be carried out by a qualified electrician. Electrical details:- Voltage: 240V 1ph 50Hz Consumption: 2W (min) 24W (max) Fuse rating: 3 Amp Note: This unit must be earthed. The three core cable from the mains power supply should be connected to a fixed wiring installation, via a fused isolator, in accordance with current EE wiring regulations. AR DFFUSER WTH FRE DAMPER For use in stairwells of three storey properties, the optional powder-coated aluminium diffuser with Fireblock provides 1 hour of fire resistance in accordance with BS476 Part 20 and SO834. SUMMER - f the loft temperature is above 24 o C air is drawn directly from outside, to provide background ventilation. n addition a boost switch is supplied to increase airflow when required. WNTER - During the colder months tempered air is drawn from the loft space taking advantage of solar gain combined with the heat conducted through the ceiling of the home. Ceiling (A) Hole in ceiling 200mm dia. Studs THE BOOST SWTCH Drimaster365 air volumes can be boosted to obtain maximum ventilation by the operation of a boost switch which is supplied with the unit. By switching the unit to boost all other settings are over-ridden. NSTALLATON KTS FOR DRMASTER365 Please note: Full details of the installation materials supplied with the unit, and optional installation materials, not supplied with the unit, which can be purchased separately from Nuaire are listed in the installation manual, leaflet number *Note: 3 storey properties must be fitted with an aluminium diffuser. (B) (C) 4 x MSx35mm screws Spacers Fixing (C) to (B) DMENSONS (MM) Drimaster365 unit. 275mm Diffuser supplied mm 301mm dia
13 DRMASTER 365 CONSULTANTS SPECFCATON FAN DESCRPTON Nuaire Drimaster365 ultra low energy positive input ventilation unit. The unit casing shall be manufactured from thermally lined pre-painted steel. The casing shall have an easily removable panel to allow access for maintenance. The unit shall incorporate a filter of G4 grade with an area of approximately 0.47m 2. The unit shall incorporate a forward curved centrifugal impeller and high efficiency brushless DC motor fitted with sealed for life, self lubricating bearings and locked rotor protection. The unit shall be supplied with a purpose designed polymer diffuser for efficient, directable air input using side blanking pieces supplied. The diffuser design shall minimise the accumulation of any condensate run off that may occur in the event of power to the unit being switched off. The ducting between the unit and the diffuser is supplied with unit. The unit shall incorporate 6 volume control settings for maximum flexibility and occupant comfort. The unit is fully automatic. f the loft temperature is below 24ºC then the unit will draw fresh air from the loft. f the loft temperature is above 24ºC then cool fresh air will be drawn from outside the dwelling. The unit shall incorporate two air inlets, one draws air from the loft, the other from outside via a 150mm dia. spigot. The unit can be boosted to obtain maximum ventilation by the operation of a boost switch (supplied). An internal monitor shall record the unit s operational time. The unit shall be offered with a 5 year warranty. For information on reducing radon egress, it is suggested that the details given in Positive pressurisation: a guide to radon remedial measures in existing dwellings may be considered. Download specification from nuaire.co.uk 141
14 DRMASTER HEAT DRMASTER HEAT (PV) NCORPORATES AN NTEGRAL HEATER WHCH CAN BE SET TO PROVDE ADDTONAL HEATNG OF THE NCOMNG AR F REQURED
15 DRMASTER HEAT BENEFTS NTEGRAL HEATER To provide additional heating of the incoming air if required e.g. during very cold weather. The heater can be used to distribute filtered, warmed air throughout the property. EASY NSTALLATON & VERY LOW MANTENANCE REQUREMENT Filter clean or replacement every 5 years. SGNFCANTLY MPROVES NDOOR AR QUALTY Using positive input ventilation removes inddor air pollutants such as carbon monoxide and keeps out traffic fumes, pollen and outdoor pollutants. COMPLES WTH THE BULDNG REGULATON REQUREMENTS Meets Part F&L England and Wales and contributes towards conservation of fuel and power. NTELLGENT HEAT RECOVERY Twin sensors optimise energy efficiency, adjusting settings to provide increased comfort. RADON GAS CONTROL Helps reduce and maintain radon gas levels. CREATES A HEALTHER LVNG ENVRONMENT High efficiency G4 filters removes up to 95% dust particles. FT & FORGET OPERATON Fully automatic when airflow set on installation. FRE DAMPER AND DFFUSER FOR 3-STOREY ACCOMMODATON AVALABLE The diffuser is manufactured from aluminium and powder coated to an off white finish (RAL 9003). Product code Drimaster-3S. SYSTEM STANDBY MODE For summer months when loft temperature exceeds 23 o C. HEALTH Clinically proven to help allergy and asthma sufferers. WARRANTY 5 year warranty for peace of mind. NSTALLATON OPTONS Self tapping screws. Ceiling diffuser. Wood screw. L shape metal brackets. Unit mounted on roof joists using two L shaped fixing brackets. Ceiling Diffuser. Download specification from nuaire.co.uk 143
16 DRMASTER HEAT DRMASTER HEAT - HOW THE SYSTEM WORKS The Drimaster-Heat provides whole home ventilation using the Positive nput Ventilation principle. Essentially the concept is to introduce fresh, filtered air into the dwelling at a continuous rate, encouraging movement of air from inside to outside. To achieve this, the unit is mounted in the loft space, drawing air through the filters and inputting it, at ceiling level, into the property. The Drimaster units are fitted with an internal temperature sensor. This sensor continuously monitors the temperature in the loft, boosting the air volume when the loft temperature is above a set level (heat recovery mode). Casing f the loft temperature becomes excessive the unit will switch to standby mode (no airflow). Once installed, the airflow can be set to suit the house size and, if required, the way it responds to the temperature changes within. The Drimaster-Heat unit incorporates an integral heater which can be set to provide additional heating of the incoming air if required e.g. during very cold weather. The heater can be used to distribute filtered, warmed air throughout the property. Code description DRMASTER-HEAT DRMASTER HEAT AR DFFUSER The unit shall be supplied with a purpose designed polymer diffuser which provides efficient, directional controllable air supply using side blanking pieces supplied. The diffuser design shall minimise the accumulation of any condensate run off that may occur in the event of power to the unit being switched off. The diffuser shall have been independently assessed for behaviour in relation to fire and adjacent smoke detectors. AR DFFUSER WTH FRE DAMPER For use in stairwells of three storey properties, the optional powder-coated aluminium diffuser with Fireblock provides 1 hour of fire resistance in accordance with BS476 Part 20 and SO834. Ceiling (A) Hole in ceiling 200mm dia. Studs (B) 4 x MSx35mm screws (C) Spacers Fixing (C) to (B)
17 DRMASTER HEAT DRMASTER HEAT - DMENSONS (mm) Drimaster-Heat Unit 900 Filter Filter Unit heater & control interface 200 dia. 290 Diffuser supplied dia. 303 Download specification from nuaire.co.uk 145
18 DRMASTER HEAT ELECTRCAL CONNECTON Please note: the electrical connection of the unit must be be carried out by a qualified electrician. Electrical details: Voltage: 240V 1ph 50Hz Consumption: Normal running: 1.6W (min) 15.3W (max), up to 500W with heater at full load. Fuse rating: 3 Amp The unit is supplied with a pre-wired power supply. This power supply unit has a metal bracket incorporating fixing holes, which should be used to fit the power supply to a suitable surface e.g. a wooden joist. The fan unit is also supplied with a fused spur. The two core mains cable from the power supply should be connected to a fixed wiring installation, via the isolator, via the spur, in accordance with current EE wiring regulations. ADJUSTNG THE TARGET TEMPERATURE The occupier will normally require the heater to activate when the loft temperature falls below a predetermined point. We recommend that the heater set point be set at 10 o C. (see figure below). nstaller sets target temperature via the heater set point. The heater will fluctuate on and off to maintain this temperature. SPEED SETTNGS The unit has 6 Air Volume (speed) settings. The setting switch is located on the side of the unit. The LED s when illuminated, indicate the corresponding Air Volume from the unit. As an example, for a one bedroom bungalow, the unit should be set onto the lowest setting (two lights on left). A five bedroom detached house would need to be set on the highest speed (all three LED s illuminated). Typical wiring: Drimaster unit and heater can be wired up via 1 fuse spur, the fuse spur must be fitted with a 3 Amp fuse. N E OUT E Heater Drimaster L OUT N L N N 240V Supply ~ Ensure the fan is running before operating the heater. f the heater should trip out the power should be isolated for several minutes to allow the unit to reset the thermal trip
19 DRMASTER HEAT CONSULTANTS SPECFCATON SPECFCATON Low energy positive input ventilation unit - for use in homes with a loft. The unit shall be robustly constructed from flame retardant VO rated ABS polymer and the casing shall be of spherical pattern with a flat mounting base. A heater section incorporating a 500w heating element shall be fitted to the fan unit. t shall be electronically controlled so as to minimise energy use. A temperature sensor shall be fitted to the outlet of the heater and will control the output of heater in an attempt to maintain the set point. The set point will be adjustable between 2 and 20ºC. Flame retardant filters of G4 grade, surface area approx 0.47m 2 (with 5 year typical maintenance period) shall be fitted, which may be removed from the unit without the use of tools. The filters shall be arranged such as to prevent their obstruction in the loft space. The unit shall incorporate a forward curved centrifugal impeller and high efficiency brushless DC motor fitted with sealed for life, self lubricating bearings and locked rotor protection. The unit s average power consumption shall be 0.16 watts per l/s of airflow (without heater element operational). The units Fixed Temperature Heat Recovery strategy shall be achieved via a sensor located in the unit and shall improve energy performance accordingly. An internal monitor shall record the unit s operational time. The unit shall be offered with a 5 year warranty. For information on reducing radon egress, it is suggested that the details given in Positive pressurisation: a guide to radon remedial measures in existing dwellings may be considered. The unit shall be supplied with a length of flexible ducting, and all necessary connectors and fixings. The unit will be supplied with brackets for fitting to joists. The unit shall be supplied with a purpose designed flame retardant polymer diffuser for efficient, direct able air input. The diffuser design shall be optimised for use in areas where smoke detectors are fitted. The unit shall include 5 programmable temperature control strategies, 6 volume control settings and an optional high duty boost setting providing an airflow rate of 70l/s for optimum performance and occupant comfort. Download specification from nuaire.co.uk 147
20 FLATMASTER TECHNCAL NFORMATON FLATMASTER - POSTVE NPUT VENTLATON (PV) LOW COST VENTLATON FOR PROPERTES WTH NO LOFT SPACE, THAT SAVES ENERGY AND PREVENTS CONDENSATON
21 FLATMASTER TECHNCAL NFORMATON BENEFTS EXTREMELY LOW POWER CONSUMPTON As low as 3 Watts. EASY NSTALLATON & VERY LOW MANTENANCE REQUREMENT Filter clean or replacement typically every 18 months. SGNFCANTLY MPROVES NDOOR AR QUALTY Using positive input ventilation removes inddor air pollutants such as carbon monoxide and keeps out traffic fumes, pollen and outdoor pollutants. COMPLES WTH THE BULDNG REGULATON VENTLATON REQUREMENTS Meets Part F&L England and Wales and contributes towards conservation of fuel and power. (Please refer to BBA Certificate). RADON GAS CONTROL Helps reduce and maintain radon gas levels. CREATES A HEALTHER LVNG ENVRONMENT High efficiency filters removes up to 95% dust particles. FT & FORGET OPERATON Fully automatic when airflow set on installation. OPTONAL HEATER FACLTY To provide additional heat to the incoming air if required i.e. during very cold weather. WARRANTY 5 year warranty for peace of mind. TYPCAL NSTALLATON Quick maintenance with easily cleaned filter. Louvered vent. Download specification from nuaire.co.uk 149
22 POSTVE NPUT EXTRACT FLATMASTER TECHNCAL NFORMATON FLATMASTER Typical installations show unit with top discharge. Alternative inlet position 'Blank off 'plate 'Blank off ' plates Rear entry The unit is designed to take fresh air from outside, clean the air, warm it (if fitted with heater) and discharge it into the central hallway via a system of ducting supplied by the installer. The dwelling internal air discharge grille is usually installed at high level in a central location within the hallway, although discharging the air down the length of the hallway (away from the front door) should also prove acceptable. Unit performance may be enhanced if an existing heat source can warm the discharged air eg. by locating the discharge grille above a radiator. FLATMASTER- HEATER KT OPTON Heater kit option - contains a blank insert with a cut out for the switch. This blank can be fitted into any appropriate opening but it is important that the switch is fitted so that the terminals are at the bottom. WRNG Please note the electrical connections to the unit should be carried out by a qualified electrician. With the PCB cover removed pull the PCB forward to gain access to earth post behind. Connect Earth cable to Earth Post next to the grommet hole. (f the heater option is required the wiring should be connected to the appropriate terminal on the PCB). Slide PCB into slot and connect the mains supply L and N to the terminal block. Electrical details:- Supply - 230V 1 phase 50Hz Power Consumption (without heater option) Speed 1-5 Watts Speed 2-8 Watts Speed 3-13 Watts Optional Heater Watts. The unit should be wired in accordance with current EE regulations. Heater option wiring for general application. Alternative heater/transformation piece position Heater/transformation piece Switch terminal connections Heater 1 Supply PCB Note: Switch must be inserted into cut out in the blanking plate with the terminals to the bottom as shown. DMENSONS (MM) & WEGHT FLATMASTER UNT Weight: 6kg 1 Neon switch plate used for all general applications (except bathroom) see below. The electrical supply for the heater is taken from the PCB terminal block and connected the two lower tags on the neon switch. The upper pair of tags on the neon accept the heater leads. 100mm dia. or 121 x 60mm interchangeable spigots supplied with unit. Alternative end spigot panels 100dia. spigot shown x 60 rectangular spigot indicated Alternative end spigot panels Alternative (knock out) spigot positions on rear face 100mm dia. only
23 FLATMASTER TECHNCAL NFORMATON CONSULTANTS SPECFCATON FAN DESCRPTON The attractively designed unit casing shall be manufactured from easy to clean flame retardant V0 rated ABS polymer and thermally insulated pre-coated mild steel. A washable flame retardant filter of G3 grade (with 1-2 year typical maintenance period) shall be fitted which may be accessed via the easily removable front cover. The unit shall incorporate an injection moulded radial bladed centrifugal impeller. The impeller shall be driven by a high efficiency, reversible brushless DC motor fitted with sealed, self lubricating bearings and locked rotor protection. The unit shall have a maximum power consumption of 0.45w/l/s of airflow. The unit shall be highly adaptable for ease of installation allowing circular or rectangular duct connections and for air entry from the side or rear of the case at high or low level. A selection of spigots enabling connection to 100mm circular or 121x60mm rectangular distribution ductwork without the use of transformation sections shall be provided. The unit shall provide 3 volume control settings. Ducting and grilles shall be supplied separately. The unit shall be suitable for the incorporation of an optional electric airtempering heater as a plug in kit (Code: FLAT-HEATER). The unit shall be offered with a 5 year warranty. Download specification from nuaire.co.uk 151
24 FLATMASTER 2000 FLATMASTER POSTVE NPUT VENTLATON (PV) LOW COST VENTLATON WTH NTEGRAL HEATER FOR PROPERTES WTH NO LOFT SPACE
25 FLATMASTER 2000 BENEFTS EXTREMELY LOW POWER CONSUMPTON As low as 5 Watts. EASY NSTALLATON & VERY LOW MANTENANCE REQUREMENT Filter clean or replacement typically every 18 months. SGNFCANTLY MPROVES NDOOR AR QUALTY Using positive input ventilation removes inddor air pollutants such as carbon monoxide and keeps out traffic fumes, pollen and outdoor pollutants. COMPLES WTH THE BULDNG REGULATON VENTLATON REQUREMENTS Meets Part F&L England and Wales and contributes towards conservation of fuel and power. (Please refer to BBA Certificate). RADON GAS CONTROL Helps reduce and maintain radon gas levels. CREATES A HEALTHER LVNG ENVRONMENT High efficiency filters removes up to 95% dust particles. FT & FORGET OPERATON Fully automatic when airflow set on installation NTEGRAL HEATER To provide additional heating of the incoming air if required e.g. during very cold weather. The heater can be used to distribute filtered, warmed air throughout the property. MANUAL BOOST SWTCH PROVDED When additional ventilation is required i.e. cooking odours. WARRANTY 5 year warranty for peace of mind. TYPCAL NSTALLATON Remote boost switch. Side input installation (view from side). nput grille (louvres slant downwards) 100mm dia/121x60mm rectangular ducting (note input side kept as short as possible) Flatmaster 2000 Alternative spigot positions Room (typical) Discharge grille (note louvres slant upwards) Hallway (typical) Outside wall Rear input installation (view from above). Outside wall Air input 100mm dia ducting Note alternative spigot positions Flatmaster 2000 Air discharge Hallway (typical) Thermostatically controlled heater. Download specification from nuaire.co.uk 153
26 POSTVE NPUT EXTRACT FLATMASTER 2000 FLATMASTER 2000 The unit is designed to take fresh air from outside, clean the air, warm it (if fitted with heater) and discharge it into the central hallway via a system of ducting supplied by the installer. The dwelling internal air discharge grille is usually installed at high level in a central location within the hallway, although discharging the air down the length of the hallway (away from the front door) should also prove acceptable. Unit performance may be enhanced if an existing heat source can warm the discharged air eg. by locating the discharge grille above a radiator. Additional heat when required f additional heating of the incoming air is required e.g. during very cold weather, the integral heater can be used to distribute filtered, warmed air throughout the property. Typical installations show unit with top discharge. Alternative inlet position 'Blank off 'plate 'Blank off ' plates Rear entry SETTNG UP THE CORRECT ARFLOW DRECTON ARFLOW Transformation piece Scroll cover Deflector plate position under scroll cover PCB Cover Fitting the deflector plate Fit deflector plate into scroll cover as shown below. Once fitted the assembly can be slotted into the scroll and clipped firmly in place. Deflector plate pinched between guide posts as shown Deflector plate position under scroll cover Deflector plate shown fitted in left hand air discharge Scroll cover Left Hand Discharge (when viewed from front) Scroll Direction of rotation (see "Setting the unit") Deflector plate shown fitted for left hand air discharge (viewed from inside). Deflector plate position under scroll cover Scroll cover Transformation piece ARFLOW Transformation Piece This should be on the appropriate scroll outlet. The transformation piece should be fitted into the chosen outlet spigot insert, prior to fitting. Note: f the round spigot is used as an outlet, the 115 x 55mm clear blanking plate will need to be fitted (as shown). This plate should be prevented from movement by the use of silicone sealant. PCB Cover Transformation piece Right Hand Discharge (when viewed from front) Direction of rotation (see "Setting the unit") Outlet spigot Blanking plate
27 FLATMASTER 2000 WRNG Please note the electrical connections to the unit should be carried out by a qualified electrician. With the PCB cover removed pull the PCB forward to gain access to earth post behind. Connect Earth cable to Earth Post next to the grommet hole. (f the heater option is required the wiring should be connected to the appropriate terminal on the PCB). Slide PCB into slot and connect the mains supply L and N to the terminal block. Electrical details:- Supply - 230V 1 phase 50Hz DMENSONS (MM) & WEGHT FLATMASTER 2000 UNT Weight: 4kg 100mm dia. or 121 x 60mm interchangeable spigots supplied with unit. Alternative end spigot panels 100dia. spigot shown x 60 rectangular spigot indicated Alternative end spigot panels Alternative (knock out) spigot positions on rear face 100mm dia. only. Download specification from nuaire.co.uk 155
28 FLATMASTER 2000 CONSULTANTS SPECFCATON FAN DESCRPTON The attractively designed unit casing shall be manufactured from easy to clean flame retardant V0 rated ABS polymer and thermally insulated pre-coated mild steel. A washable flame retardant filter of G3 grade (with 1-2 year typical maintenance period) shall be fitted which may be accessed via the easily removable front cover. The unit shall incorporate an injection moulded radial bladed centrifugal impeller. The impeller shall be driven by a high efficiency, reversible brushless DC motor fitted with sealed, self lubricating bearings and locked rotor protection. The unit shall have a maximum power consumption of 1.4 w/l/s of airflow. The unit shall be highly adaptable for ease of installation allowing circular or rectangular duct connections and for air entry from the side or rear of the case at high or low level. A selection of spigots enabling connection to100mm circular or 121x60mm rectangular distribution ductwork without the use of transformation sections shall be provided. The unit shall provide 3 volume control settings. Ducting and grilles shall be supplied separately. The unit shall be suitable for the incorporation of an optional plug in internal monitor which shall record the units operational time (Code: FLAT-HRM). The unit shall be offered with a 5 year warranty
squrboxbox heat recovery squrboxbox I technical information
heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution
MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand
9041381- Issue 6 4/11 MODEL: DV72 Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation: Configuration
NUAIRE VENTILATION SYSTEMS FLATMASTER AND FLATMASTER 2000 SYSTEMS
NuAire Ltd Western Industrial Estate Caerphilly Mid Glamorgan CF83 1NA Tel: 02920 858 200 Fax: 02920 858 300 e-mail: [email protected] website: www.nuaire.co.uk NUAIRE VENTILATION SYSTEMS APPROVAL INSPECTION
NUAIRE VENTILATION SYSTEMS DRIMASTER, DRIMASTER 3S, DRIMASTER 2000 AND DRIMASTER 2000 3S SYSTEMS
NuAire Ltd Western Industrial Estate Caerphilly Mid Glamorgan CF83 1NA Tel: 029 2085 8200 Fax: 029 2085 8300 e-mail: [email protected] website: www.nuaire.co.uk Agrément Certificate 00/3727 Product Sheet
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts
Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
UDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
IH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010
EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard
Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard Duplexvent DV72 EC MVHR is designed to provide constant volume ventilation levels to exceed the latest Building Regulations 2010. The
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
LUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
plumbing products guide
plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly
Case Study Family Room Renovation 3br family home, Melbourne
Family Room Renovation 3br family home, Melbourne In a Nutshell With time and budget constraints we often renovate just one room at a time. This case study looks at a family room renovation where the key
Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery
Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6
INSTALLATION & USER INSTRUCTIONS
INSTALLATION & USER INSTRUCTIONS LED ELECTRIC FIRE Focal Point Fires plc. Christchurch, Dorset BH23 2BT Tel: 0202 499330 Fax: 0202 499326 www.focalpointfires.co.uk e : [email protected] MODELS
CADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC
Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Mistrale. Fusion Terminal
Mistrale Fusion Terminal PUBLICATION NATURAL VENT. 1 SEPT 2015 Features - Slimline energy efficient ventilation solution - Standard and high capacity terminals provide 128 or 256 L/s capacity - Compliant
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort
Heat Pump Product Brochure 2015/2016 Premier Series Hi-Wall Split Systems Everyday Comfort Everyday Innovation We design with you in mind. You ll find that Haier Heat Pump units are quiet, efficient and
Energy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
HDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
Operation and Installation Manual. Max Series
Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55
Frequently Asked Questions Air Top Diesel Heaters 2000STC, Evo 40 & Evo 55 Question 1 What power outputs are the heaters available in? There are 3 models 2kW, 4kW and 5.5kW Question 2 What voltage are
Medical Lighting. XL4 Patient Light
Medical Lighting XL4 Patient Light The XL4 is the new ergonomically designed, energy efficient patient light from EDL Lighting Limited. Its purpose is to cover a spectrum of applications within the Healthcare
NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!
Flexit SL4 R Air Handling Unit with rotating recovery system Energy-efficient New control system NEW! Patent applied for! - Simple settings - Flexible installation - User friendly F O R H E A LT H Y I
INSTALLER INSTRUCTIONS
230V~ SMOKE & HEAT ALARMS ALKALINE BATTERY BACK-UP Ei141RC - Ionisation Ei144RC - Heat Ei146RC - Optical RECHARGEABLE LITHIUM CELL BACK-UP Ei161RC - Ionisation Ei164RC - Heat Ei166RC - Optical INSTALLER
BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION
Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION
Apartment and Communal Heating Solutions
Apartment and Communal Heating Solutions Apartment and Communal Heating Due to the increasing requirements for more energy efficient buildings and changes to the Code for Sustainable Homes Legislation,
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
3 IN 1 BATHROOM HEATER
3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing
TFSR & TFSK Roof Fans
Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans TFSR & TFSK Roof Fans With swing-out function 2 I TFSR/TFSK TFSR & TFSK Roof
Glossary of HVAC Terms
Glossary of HVAC Terms Heating, Ventilation and Air Conditioning (HVAC) is a major sub- discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
The space saving solution.
10 KICKSPACE KICKSPACE. Over 70% of people think that they would benefit from additional kitchen space (ICM Research 2012) Kitchen kindly supplied by Second Nature kitchens - www.sncollection.co.uk The
UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual
UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580
Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor
DIMENSIONS SELV MODELS
25 CURZON - 1mm CENTRIFUGL FNS DIMENSIONS B Ø C D E Measured in mm : 216 B : 195 C : 5 D : 52 E : 98 Ø* * : 8/1 * (8mm without adaptor 1mm with adaptor) CURZON - 1mm CENTRIFUGL FNS 14 12 1 8 6 4 2 14 12
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
Owner s Guide and Installation Manual. Vancouver Model Name. 21321, 21328 Model No. English Español
For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Vancouver Model Name 21321, 21328 Model No. Type A Models Owner s Guide and Installation
Building Control. Householder Guidance Leaflet No. 29. Fire detection in dwellings
Building Control Householder Guidance Leaflet No. 29 Fire detection in dwellings This leaflet is one of a series produced by the Hertfordshire Building Control Technical Forum GUIDANCE NOTE FOR HOME OWNERS
HeatSource HS1800 Heater
HeatSource HS1800 Heater Vehical Installation & Operating Instructions Propex Heatsource Ltd Unit 5, Second Avenue Buisness Park, Milbrook, Southampton, SO15 OLP Tel: 023 8052 8555 Fax: 023 8052 8800 Website:
BATHROOM HEATER. User's Manual. Page 2...A515 Page 9...A716
BATHROOM HEATER User's Manual Page 2...A515 Page 9...A716 BATHROOM HEATER User's Manual A515 SAVE THESE INSTRUCTIONS AND READ ALL INSTRUCTIONS BEFORE USING THE HEATER. Dear customers, Thank you for selecting
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136
19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.
19" Data Racks Attractive design and high quality are characteristic. Basic framework is welded from multiple bent metal plate, which assures great rigidity suitable for heavier equipment. All profile
Andersen Electric Window Opener for Andersen Awning and Roof Windows
W A Electric Window Opener Electric Window Opener for Awning and Roof Windows Congratulations! You have just purchased one of the many fine products. For ease of installation and continued enjoyment of
Heating and cooling. Insulation. Quick facts on insulation:
Heating and cooling Heating and cooling your home can be one of the biggest users of energy. Efficency in this area can bring great savings. Heating and cooling depend on many contributing factors. The
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)
OPERATION MANUAL Split System Ducted Air Conditioner To suit Daikin FDY "F" Series and FD "F" Series AIR CONDITIONER A hr o C (and other models incorporating BRC1B62/52 Remote Controller) Dear Owner, Thank
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable
tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable Port side cable (with black cable tie attached) Power cable Preparing for Installation 1 Overall
Gree Solar Hybrid Hi Wall Inverter Air Conditioner
Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar
Atlanta CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT A QUALIFIED ELECTRICIAN
OWNERS INSTRUCTION MANUAL 30 /76cm Atlanta INSTALLATION OPERATION MAINTENANCE CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. IF UNSURE CONSULT A QUALIFIED ELECTRICIAN PAGE
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-5 For Use with Bard CH Series 3, 4 & 5 Ton 2-Stage Wall Mount Heat Pumps AND W38H, W43H, W49H and W61H Single Stage Wall Mount
Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions
Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3.022144 (Hard Wired) Part No 3.022143 (Radio Frequency) Installation and User Instructions 1. Description The Alpha Climatic energy
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
Roof Top Unit. Description Model Type Use With Air Distribution Box. Heat Pump B3200 3242 3311669.018 Integral Mechanical
RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Type Number Product Number Serial Number ADB Number ADB Serial Number Date Purchased Roof Top Unit Description Model Type Use With Air Distribution Box
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Direct Fresh Air Free Cooling of Data Centres
White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The
(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark
Spectrum Laboratories Ltd is accredited by International Accreditation New Zealand (formerly Telarc). The tests reported herein have been performed in accordance with the terms of our accreditation. This
hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
Building Control Guidance Note
Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
User's Instructions. Alpha HE CB25/33 and HE SY25
User's Instructions Alpha HE CB25/33 and HE SY25 Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Boiler Range For Technical help or for Service call... ALPHA HELPLINE Tel:
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
WINDOW ROOM AIR CONDITIONER
WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please
8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!
Bathroom and toilet extract fans SILENT-100 BATHROOM EXTRACT FANS SILENT-100 Series SILVER versions The SILENT-100 CZ and CRZ can be supplied Range of axial extractors with airflow rates of approx. 95
Green Line HRX Ceiling Mounted
Green Line HRX Ceiling Mounted Mechanical Ventilation with Heat Recovery appliance Installation and Operating Instructions Models: HRX-S-C, HRX-B-C, HRX-FP-C, HRX-BFP-C These instructions must be given
One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty
One Year Warranty ELECTRIC Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches Fused Ceramic Shield tank lining is corrosion-resistant for years of dependability. Adjustable
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
FLEXIT S3 X/TT A3 X/TT K3 X/TT S3 R S3 RK
944E-05 006-0 FLEXIT S X/TT A X/TT K X/TT S R S RK Installation Instructions Air Handling Unit/ Kitchen Model S X/TT K X/TT A X/TT S R S RK Air handling unit with cross heat exchangeror TT exchanger Air
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI Page 2 / 16 CONTENTS 1 GENERAL... 3 2 SAFETY... 3 2.1 Safety instructions... 3 2.2 Correct use... 3 3 DESCRIPTION
Surface Technology. Centrifugal Fan GMD
Centrifugal Fan ATEX classed adapted for paint shops Wide assortment broad area of application Service friendly low maintenance costs Headquarters: Centrifugal Fan Centrifugal Fan is a direct driven industrial
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
DSRQ - DSRSQ - DSRSQ-THERM
DSRQ - DSRSQ - DSRSQ-THERM Specification item: Variable geometry diffuser on 597x597 mm panel developed for rooms with high ceilings where a long throw and a high induction ratio are required. Made up
AerAtron. Ceiling fans
AerAtron Ceiling fans User Manual & Technical Specifications Models: e502 & e503 Electricians PLEASE FOLLOW THESES INSTRUCTIONS CAREFULLY & PAY SPECIAL ATTENTION TO THE NOTES NOTES WILL ASSIST WITH AN
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
Under sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
SERVICE SERVICE COMPACT MANUAL. Mod. 3000 92X Mod. 3000 93X Mod. 3000 94X. Part 2
SERVICE COMPACT SERVICE 000 MANUAL Mod. 000 9X Mod. 000 9X Mod. 000 94X Part Forward This Service Handbook is intended to assist with servicing and fault-finding in Caravans and Motor Caravans equipped
SPECIAL APPLICATIONS
Page 1 SPECIAL APPLICATIONS The protection of microelectronics clean rooms using aspirating smoke detection systems requires special consideration. The physical configuration of the room(s) and the direction
Model. Roof-Top Air Conditioner CARAVAN MODEL B3200 TYPE 3253.331 INSTALLATION & OPERATING INSTRUCTIONS B3200
RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number Serial Number Date Purchased Roof-Top Air Conditioner CARAVAN MODEL B200 TYPE 25.1 SERVICE OFFICE Dometic Corporation For Information Contact:
FULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor