COBALT Migration Utility. User Manual
|
|
|
- Elijah Jackson
- 10 years ago
- Views:
Transcription
1 COBALT Migration Utility User Manual
2 2000 Cobalt Networks, Inc. All rights reserved. Part Number: Date: Cobalt Networks, Cobalt RaQ and RaQ are trademarks of Cobalt Networks, Inc. All other company, brand and product names may be registered trademarks or trademarks of their respective companies and are hereby recognized. This publication and the information herein is furnished AS IS, subject to change without notice, and should not be construed as a commitment by Cobalt Networks, Inc. Furthermore, Cobalt Networks, Inc., assumes no responsibility or liability for any errors or inaccuracies, makes no warranty of any kind (express, implied or statutory) with respect to this publication, and expressly disclaims any and all warranties of merchantability, fitness for particular purposes and non-infringement of third-party rights. Cobalt Networks, Inc. 555 Ellis Street Mountain View, CA In the U.S.A.: Phone (888) 70-COBALT (650) Fax (650) Outside the U.S.A.: Phone +1 (650) Fax +1 (650)
3 Overview of the Cobalt Migration Utility Introduction Migration is the transfer of configured data from one server appliance to another. This operation is performed by executing commands on a source machine to produce intermediate files. These files are then transferred to a target machine where the files are expanded and loaded. You can move different levels of configuration data with the Cobalt Migration Utility (CMU): all virtual sites a single virtual site Migrating a virtual site automatically moves all of the corresponding users as well. Important: Cobalt recommends that you run meta-verify both before an export operation and after an import operation. Meta-verify is available for the RaQ 3 and RaQ 4 only. For the RaQ 3, it can be found at ftp://ftp.cobaltnet.com/pub/users/duncan/raq3/meta-verify.pl For the RaQ 4, it ships on the box and is located in /usr/local/sbin/ with the name meta-verify. 1
4 Full Virtual Site and User Migration A Full Virtual Site and User Migration consists of migrating all of the virtual sites and users from one server appliance (source) to another appliance (target) that you have already configured. The target appliance must be located on the network and be fully configured. There may or may not be any virtual sites or users on the target appliance, but there is always a base virtual site. For this example, the target appliance is clean base setup; a clean base setup assumes that you have configured the target appliance with an IP address, gateway and netmask through the LCD console or the serial console port. You must also complete the initial Setup Wizard screens on the target appliance which configures such things as a Domain Name System (DNS) server and the administrator password. To perform a Full Virtual Site and User Migration, perform the following steps: The items shown in bold typeface are commands to be executed by the person performing the migration. The items shown in courier font are directory paths. 1. <on source appliance> Suspend all virtual sites through the browser-based user interface (UI). This disables user access and services. Refer to the user manual for details on how to suspend a virtual site. Suspending virtual sites is not supported on the RaQ2. 2. <on source appliance> Telnet in as admin and su- to root. 3. <on source appliance> Edit /etc/crontab in your preferred editor and insert a # in front of the following line: For the RaQ 2: 0,15,30,45 * * * * root /usr/local/sbin/monitor For the RaQ 3 and RaQ 4: 0,15,30,45 * * * * root /usr/local/sbin/swatch >>/var/cobalt/adm.log 2>&1 This prevents Active Monitor from restarting stopped services. 4. <on source appliance> Kill the sendmail process. Execute kill `head -1 /var/run/sendmail.pid`. 5. <on source appliance> Execute /usr/sbin/cmuexport. This is the main export script and it outputs a directory with the fully qualified domain name of the main site under /home/cmu. 6. <on target appliance> Set up the target appliance so that it can communicate with the source appliance. 7. <on source appliance> FTP to the target appliance and transfer the contents of the directory created in Step 5 from the source appliance into a temporary directory on the target appliance. 2
5 8. <on target appliance> Telnet in as admin and su- to root. 9. <on target appliance> Execute /usr/sbin/cmuimport -d <dirname>, where <dirname> is the temporary directory to which you transferred the contents in Step 7. This is the main import script and transfers all virtual sites and users to the target appliance. 10. <on source appliance> Edit /etc/crontab in your preferred editor and remove the # added in Step 3 in front of the following line: For the RaQ 2: 0,15,30,45 * * * * root /usr/local/sbin/monitor For the RaQ 3 and RaQ 4: 0,15,30,45 * * * * root /usr/local/sbin/swatch >>/var/cobalt/adm.log 2>&1 11. <on source appliance> To restart sendmail, execute the following command: For the RaQ 2: /usr/local/sbin/monitor For the RaQ 3 and RaQ 4: /usr/local/sbin/swatch Selective Virtual Site Migration A Selective Virtual Site Migration consists of migrating a single virtual site and its associated users from one server appliance (source) to another appliance (target) that you have already configured. The target appliance must be located on the network and be fully configured. There may or may not be any virtual sites or users on the target appliance. 1. <on source appliance> Execute steps 1-4 from the Full Virtual Site and User Migration on page <on source appliance> Execute /usr/sbin/cmuexport -n <fqdn>, where <fqdn> is the fully qualified domain name of the single virtual site you wish to move. 3. Execute steps 6-11 from Full Virtual Site and User Migration on page 2 to the appropriate target appliance. 3
6 Server Replacement A Server Replacement consists of replacing an existing RaQ server with a new one. This implies that the new appliance has the same IP address as the original appliance and that the original appliance is removed from the network. There are no changes to the network. The items shown in bold typeface are commands to be executed by the person performing the migration. The items shown in courier font are directory paths. 1. <on new appliance> Set up the new appliance on the network and configure the base system. This appliance should have a different IP address than the original appliance at this time but must be accessible by the original appliance. 2. <on original appliance> Suspend all virtual sites through the browser-based user interface (UI). This disables user access and services. Refer to the user manual for details on how to suspend a virtual site. Suspending virtual sites is not supported on the RaQ2. 3. <on original appliance> Telnet in as admin and su- to root. 4. <on original appliance> Edit /etc/crontab in your preferred editor and insert a # in front of the following line: For the RaQ 2: 0,15,30,45 * * * * root /usr/local/sbin/monitor For the RaQ 3 and RaQ 4: 0,15,30,45 * * * * root /usr/local/sbin/swatch >>/var/cobalt/adm.log 2>&1 This prevents Active Monitor from restarting stopped services. 5. <on original appliance> Kill the sendmail process. Execute kill `head -1 /var/run/sendmail.pid`. 6. <on original appliance> Execute /usr/sbin/cmuexport. This is the main export script and it outputs a directory with the fully qualified domain name of the main site under /home/cmu. 7. <on original appliance> FTP to the new appliance and transfer the contents of the directory created in Step 6 into a temporary directory on the new appliance. 8. Make note of the network settings of the original appliance and then remove the original appliance from the network. 9. <on new appliance> Reset the network settings of the new appliance to those of the original appliance. By assigning to the new appliance the same network settings as the original appliance, you do not have to change or adjust the IP addresses of the virtual sites that you are going to migrate. 10. <on new appliance> Telnet in as admin and su- to root. 11. <on new appliance> Execute /usr/sbin/cmuimport -d <dirname>, where <dirname> is the temporary directory to which you transferred the contents in Step 7. This is the main import script and transfers all virtual sites and users to the target appliance. 4
7 Mounted File System Migration The Mounted File System Migration is only available on a RaQ 3-to-RaQ 4 migration. The items shown in bold typeface are commands to be executed by the person performing the migration. The items shown in courier font are directory paths. The best approach to migration is to use a mounted file system to transfer the data. This involves mounting a directory from the target appliance to the source appliance. On the source appliance, you then execute the export script to the mount directory. The following scenario discusses a migration from a RaQ 3 appliance to a RaQ4 appliance. In this scenario, the target appliance (RaQ 4) has 100% more free disk space than is used on the source appliance (RaQ 3). 1. <on target appliance> Telnet in as admin and su- to root. 2. <on target appliance> Edit /etc/exports in your preferred editor and add the following line. Replace the sample IP address of with the actual IP address of the source appliance. /home/migrate/ (rw,no_root_squash) 3. <on target appliance> Execute mkdir /home/migrate. 4. <on target appliance> Execute /etc/rc.d/init.d/portmap start. 5. <on target appliance> Execute /etc/rc.d/init.d/nfs start. 6. <on source appliance> Telnet in as admin and su- to root. 7. <on source appliance> Execute mkdir /mnt/migrate. 8. <on source appliance> Execute mount :/home/migrate /mnt/migrate. Replace the sample IP address of with the actual IP address of the target appliance. 9. <on source appliance> You can now access the target appliance directory /home/migrate as /mnt/migrate. 10. <on source appliance> Suspend all virtual sites through the browser-based UI. This disables user access and services. Refer to the user manual for details on how to suspend a virtual site. 11. <on source appliance> Telnet in as admin and su- to root. 12. <on source appliance> Edit /etc/crontab in your preferred editor and insert a # in front of the following line: 0,15,30,45 * * * * root /usr/local/sbin/swatch >>/var/cobalt/adm.log 2>&1 This prevents Active Monitor from restarting stopped services. 13. <on source appliance> Kill the sendmail process. Execute kill `head -1 /var/run/sendmail.pid`. 14. <on source appliance> Execute /usr/sbin/cmuexport -d /mnt/migrate. 15. <on target appliance> Execute /usr/sbin/cmuimport -d /home/migrate 5
8 16. To restore your appliances to their original states: a. <on target appliance> Telnet in as admin and su- to root Remove the line from /etc/exports that was added in Step 2. Execute /etc/rc.d/init.d/nfs stop Execute /etc/rc.d/init.d/portmap stop b. <on source appliance> Telnet in as admin and su- to root Ensure that no one is logged in to the appliance and that no programs are using files from /mnt/migrate. Execute umount /mnt/migrate Execute rmdir /mnt/migrate 17. <on source appliance> Edit /etc/crontab in your preferred editor and remove the # added in Step 12 in front of the following line: 0,15,30,45 * * * * root /usr/local/sbin/swatch >>/var/cobalt/adm.log 2>&1 18. <on source appliance> To restart sendmail, execute /usr/local/sbin/swatch. Possible Conflicts When the cmuimport script is executed, conflicts may arise. The settings imported from the source appliance may conflict with existing settings on the target appliance. For example, you may attempt to import a virtual site from a source appliance which has the same fully qualified domain name as an existing virtual site on the target appliance. CMU handles conflicts according to the policy.xml file located in /etc/cmu/conf. When a conflict arises, the user is given several options, which can include drop, quit, change or ignore. On the terminal console, CMU prompts the user with the nature of the conflict and the available options to resolve it. The following actions occur when each option is selected. Drop. The conflicting setting or object and its children from the imported source appliance are not imported. Selecting this option may drop a Virtual Site and all its Users. Quit. CMU ends. Change. The user is allowed to enter an alternate value to substitute for the conflicting value from the source appliance. Ignore. The conflict is ignored and the setting is imported to the target appliance. Upon completion, a log file is created. This file contains all of the changes (for example, the virtual sites or the users added) to the target appliance, including the outcome of any conflict resolution. The log file is plain text and by default is stored in /home/cmu/cmulog. 6
9 Troubleshooting tips If an export of a complete server fails, use the -c configuration option (cmuexport -c). If the export still fails, use the -n and export the virtual sites one at a time (cmuexport -n sitename). If a user s password does not work after the import operation is complete, have the user try the default password specified in the configuration file in /etc/cmu/cmu.conf (the default pasword is abc123). If a user s password does not work for FrontPage but does work for all other services (FTP, POP and so on), disable and then re-enable FrontPage Server Extensions for that user. If you want to change the IP address before importing the destination, you can edit the cmu.xml file and change the vsipaddr field to: <vsipaddr value=" "/> If you have an export of an entire RaQ but only want to restore one virtual site, use the -n option on the cmuimport command (cmuimport -n sitename). Release Notes The following functions are not supported in this release of CMU. 1. A bandwidth limit set on a virtual site is not migrated by any of the migration methods. You must manually reset the bandwidth limit on the new appliance for each virtual site. 2. The spool for a user may not be migrated to the new appliance. However, a copy of the spool is placed in the user s home directory. 3. Chili!Soft configurations will not be automatically migrated. CMU reads its configuration information from the global configuration file /etc/cmu/cmu.conf. There must be an entry for each field of the configuration file, with entries for each field separated by an equal sign. Comments are denoted by a # at the beginning of a line. # cmu.conf # # Global configuration options for cmuexport and cmuimport # Name of the xml file that contains all configuration data cmuxml = cmu.xml # Location of the Policy file policyfile = /etc/cmu/policy.xml # Stage directory: location where files are stored on a temp basis tmpdir = /home/tmp # Destination directory: location on export where the final export resides # fqdn is appended to this destdir = /home/cmu # Lib directory: contains the storage location of all product speficic libs libdir = /usr/lib/cmu/lib 7
10 # Web root prefix (for example, /home/httpd/ ) webprefix = /home/sites # Log file where all transactions are logged logfile = /home/cmu/cmulog # Turn debug on? debug = 0 # Print debug messages to stdout stddebug = 1 # Default Password # This sections contains defaults passwords. # FrontPage root web default password: used if you are moving from a RaQ 2 or RaQ 3 to a RaQ 4 fpxdflpasswd = abc123 # User default password: used when adding a user but before the crypt password is added to the /etc/shadow file userdflpasswd = abc123 # Confiiguration directives for moving files md5bin = /usr/bin/md5sum md5lst = backup.md5lst tarbin = /bin/tar spooldir = /var/spool/mail vacationdir = /var/vacation excludes = _vti tarflags = -c tapesize =
Sun Cobalt Migration Utility. User Manual
Sun Cobalt Migration Utility User Manual 2000-2001 Cobalt Networks, Inc. All rights reserved. Part Number: 070-00336-01 Date: 05-2001 The Cobalt logo, Cobalt Networks, Cube, Cobalt Qube, Qube, Cobalt RaQ,
VERITAS Backup Exec TM 10.0 for Windows Servers
VERITAS Backup Exec TM 10.0 for Windows Servers Quick Installation Guide N134418 July 2004 Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software
Disaster Recovery on the Sun Cobalt RaQ 3 Server Appliance with Third-Party Software
Technical Paper Disaster Recovery on the Sun Cobalt RaQ 3 Server Appliance with Third-Party Software The Sun Cobalt RaQ 3 server appliance supports the use of third-party backup solutions for performing
RED HAT SECURE WEB SERVER 3.0 DEVELOPER EDITION FOR COBALT NETWORKS SERVERS
RED HAT SECURE WEB SERVER 3.0 DEVELOPER EDITION FOR COBALT NETWORKS SERVERS Cobalt Secure Web Server (SSL) Cobalt Networks, Inc Features: 128 bit Encryption* Based on Redhat's Secure Server Apache 1.3.6
RSA Authentication Manager 7.1 to 8.1 Migration Guide: Upgrading RSA SecurID Appliance 3.0 On Existing Hardware
RSA Authentication Manager 7.1 to 8.1 Migration Guide: Upgrading RSA SecurID Appliance 3.0 On Existing Hardware Contact Information Go to the RSA corporate website for regional Customer Support telephone
Offline Data Transfer to VMWare vcloud Hybrid Service
Offline Data Transfer to VMWare vcloud Hybrid Service vcloud Connector 2.5.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced
User Document. Adobe Acrobat 7.0 for Microsoft Windows Group Policy Objects and Active Directory
Adobe Acrobat 7.0 for Microsoft Windows Group Policy Objects and Active Directory Copyright 2005 Adobe Systems Incorporated. All rights reserved. NOTICE: All information contained herein is the property
Setup Guide Access Manager 3.2 SP3
Setup Guide Access Manager 3.2 SP3 August 2014 www.netiq.com/documentation Legal Notice THIS DOCUMENT AND THE SOFTWARE DESCRIBED IN THIS DOCUMENT ARE FURNISHED UNDER AND ARE SUBJECT TO THE TERMS OF A LICENSE
Sage HRMS 2014 Sage Employee Self Service Tech Installation Guide for Windows 2003, 2008, and 2012. October 2013
Sage HRMS 2014 Sage Employee Self Service Tech Installation Guide for Windows 2003, 2008, and 2012 October 2013 This is a publication of Sage Software, Inc. Document version: October 17, 2013 Copyright
Interworks. Interworks Cloud Platform Installation Guide
Interworks Interworks Cloud Platform Installation Guide Published: March, 2014 This document contains information proprietary to Interworks and its receipt or possession does not convey any rights to reproduce,
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Version 7.2 November 2015 Last modified: November 3, 2015 2015 Nasuni Corporation All Rights Reserved Document Information Testing
RSA Security Analytics. S4 Broker Setup Guide
RSA Security Analytics S4 Broker Setup Guide Copyright 2010-2013 RSA, the Security Division of EMC. All rights reserved. Trademarks RSA, the RSA Logo and EMC are either registered trademarks or trademarks
Use QNAP NAS for Backup
Use QNAP NAS for Backup BACKUP EXEC 12.5 WITH QNAP NAS Copyright 2010. QNAP Systems, Inc. All Rights Reserved. V1.0 Document revision history: Date Version Changes Apr 2010 1.0 Initial release Note: Information
Symantec Database Security and Audit 3100 Series Appliance. Getting Started Guide
Symantec Database Security and Audit 3100 Series Appliance Getting Started Guide Symantec Database Security and Audit 3100 Series Getting Started Guide The software described in this book is furnished
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario
Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario Version 7.0 July 2015 2015 Nasuni Corporation All Rights Reserved Document Information Testing Disaster Recovery Version 7.0 July
Dell One Identity Cloud Access Manager 8.0.1- How to Configure for High Availability
Dell One Identity Cloud Access Manager 8.0.1- How to Configure for High Availability May 2015 Cloning the database Cloning the STS host Cloning the proxy host This guide describes how to extend a typical
VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide
VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide N109548 Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software Corporation makes
Cloud.com CloudStack Community Edition 2.1 Beta Installation Guide
Cloud.com CloudStack Community Edition 2.1 Beta Installation Guide July 2010 1 Specifications are subject to change without notice. The Cloud.com logo, Cloud.com, Hypervisor Attached Storage, HAS, Hypervisor
ADS Integration Guide
ADS Integration Guide Document version 9402-1.0-18/10/2006 Cyberoam ADS Integration Guide IMPORTANT NOTICE Elitecore has supplied this Information believing it to be accurate and reliable at the time of
Adobe Acrobat 9 Deployment on Microsoft Systems Management
Adobe Acrobat 9 Deployment on Microsoft Systems Management Server white paper TABLE OF CONTENTS 1. Document overview......... 1 2. References............. 1 3. Product overview.......... 1 4. Installing
Hyper V Windows 2012 and 8. Virtual LoadMaster for Microsoft Hyper V on Windows Server 2012, 2012 R2 and Windows 8. Installation Guide
Virtual LoadMaster for Microsoft Hyper V on Windows Server 2012, 2012 R2 and Windows 8 Installation Guide VERSION: 3.0 UPDATED: SEPTEMBER 2015 Copyright Notices Copyright 2002 2015 KEMP Technologies, Inc..
Citrix XenServer Workload Balancing 6.5.0 Quick Start. Published February 2015 1.0 Edition
Citrix XenServer Workload Balancing 6.5.0 Quick Start Published February 2015 1.0 Edition Citrix XenServer Workload Balancing 6.5.0 Quick Start Copyright 2015 Citrix Systems. Inc. All Rights Reserved.
Acronis Backup & Recovery 11.5 Quick Start Guide
Acronis Backup & Recovery 11.5 Quick Start Guide Applies to the following editions: Advanced Server for Windows Virtual Edition Advanced Server SBS Edition Advanced Workstation Server for Linux Server
Adobe Acrobat 9 Deployment on Microsoft Windows Group Policy and the Active Directory service
Adobe Acrobat 9 Deployment on Microsoft Windows Group Policy and the Active Directory service white paper TABLE OF CONTENTS 1. Document overview......... 1 2. References............. 1 3. Product overview..........
CORPORATE HEADQUARTERS Elitecore Technologies Ltd. 904 Silicon Tower, Off. C.G. Road, Ahmedabad 380015, INDIA www.cyberoam.com 7300-1.
CYBEROAM - ADS INTEGRATION GUIDE VERSION: 7 7300-1.0-9/20/2005 2 IMPORTANT NOTICE Elitecore has supplied this Information believing it to be accurate and reliable at the time of printing, but is presented
Intel Storage System SSR212CC Enclosure Management Software Installation Guide For Red Hat* Enterprise Linux
Intel Storage System SSR212CC Enclosure Management Software Installation Guide For Red Hat* Enterprise Linux Order Number: D58855-002 Disclaimer Information in this document is provided in connection with
2 Downloading Access Manager 3.1 SP4 IR1
Novell Access Manager 3.1 SP4 IR1 Readme May 2012 Novell This Readme describes the Novell Access Manager 3.1 SP4 IR1 release. Section 1, Documentation, on page 1 Section 2, Downloading Access Manager 3.1
Using Symantec NetBackup with Symantec Security Information Manager 4.5
Using Symantec NetBackup with Symantec Security Information Manager 4.5 Using Symantec NetBackup with Symantec Security Information Manager Legal Notice Copyright 2007 Symantec Corporation. All rights
Oracle WebLogic Server
Oracle WebLogic Server Creating Templates and Domains Using the pack and unpack Commands 10g Release 3 (10.3) November 2008 Oracle WebLogic Server Oracle Workshop for WebLogic Oracle WebLogic Portal Oracle
TIBCO Fulfillment Provisioning Session Layer for FTP Installation
TIBCO Fulfillment Provisioning Session Layer for FTP Installation Software Release 3.8.1 August 2015 Important Information SOME TIBCO SOFTWARE EMBEDS OR BUNDLES OTHER TIBCO SOFTWARE. USE OF SUCH EMBEDDED
NetBak Replicator 4.0 User Manual Version 1.0
NetBak Replicator 4.0 User Manual Version 1.0 Copyright 2012. QNAP Systems, Inc. All Rights Reserved. 1 NetBak Replicator 1. Notice... 3 2. Install NetBak Replicator Software... 4 2.1 System Requirements...
Radius Integration Guide Version 9
Radius Integration Guide Version 9 Document version 9402-1.0-18/10/2006 2 IMPORTANT NOTICE Elitecore has supplied this Information believing it to be accurate and reliable at the time of printing, but
CA XOsoft Replication for Windows
CA XOsoft Replication for Windows Microsoft SQL Server Operation Guide r12.5 This documentation and any related computer software help programs (hereinafter referred to as the Documentation ) is for the
Active Directory integration with CloudByte ElastiStor
Active Directory integration with CloudByte ElastiStor Prerequisite Change the time and the time zone of the Active Directory Server to the VSM time and time zone. Enabling Active Directory at VSM level
By the Citrix Publications Department. Citrix Systems, Inc.
Licensing: Setting Up the License Server on a Microsoft Cluster By the Citrix Publications Department Citrix Systems, Inc. Notice The information in this publication is subject to change without notice.
Quest ChangeAuditor 4.8
Quest ChangeAuditor 4.8 Migration Guide Copyright Quest Software, Inc. 2009. All rights reserved. This guide contains proprietary information protected by copyright. The software described in this guide
Rebasoft Auditor Quick Start Guide
Copyright Rebasoft Limited: 2009-2011 1 Release 2.1, Rev. 1 Copyright Notice Copyright 2009-2011 Rebasoft Ltd. All rights reserved. REBASOFT Software, the Rebasoft logo, Rebasoft Auditor are registered
Dialogic 4000 Media Gateway Series as a Survivable Branch Appliance for Microsoft Lync Server 2010
Dialogic 4000 Media Gateway Series as a Survivable Branch Appliance for Microsoft Lync Server 2010 Deployment Guide December 2011 64-1146-02 www.dialogic.com Copyright and Legal Notice Copyright 2011 Dialogic
Active Directory Rights Management Service Integration Guide
Active Directory Rights Management Service Integration Guide Preface Preface 2013 SafeNet, Inc. All rights reserved. Part Number: 007-011230-001 (Rev F, 07/2013) All intellectual property is protected
EMC Data Domain Management Center
EMC Data Domain Management Center Version 1.1 Initial Configuration Guide 302-000-071 REV 04 Copyright 2012-2015 EMC Corporation. All rights reserved. Published in USA. Published June, 2015 EMC believes
Setup Guide Access Manager Appliance 3.2 SP3
Setup Guide Access Manager Appliance 3.2 SP3 August 2014 www.netiq.com/documentation Legal Notice THIS DOCUMENT AND THE SOFTWARE DESCRIBED IN THIS DOCUMENT ARE FURNISHED UNDER AND ARE SUBJECT TO THE TERMS
SuperLumin Nemesis. Administration Guide. February 2011
SuperLumin Nemesis Administration Guide February 2011 SuperLumin Nemesis Legal Notices Information contained in this document is believed to be accurate and reliable. However, SuperLumin assumes no responsibility
EventTracker: Configuring DLA Extension for AWStats Report AWStats Reports
EventTracker: Configuring DLA Extension for AWStats Report AWStats Reports Publication Date: Oct 18, 2011 EventTracker 8815 Centre Park Drive Columbia MD 21045 www.eventtracker.com About This Guide Abstract
Quick Start Guide. for Installing vnios Software on. VMware Platforms
Quick Start Guide for Installing vnios Software on VMware Platforms Copyright Statements 2010, Infoblox Inc. All rights reserved. The contents of this document may not be copied or duplicated in any form,
F-SECURE MESSAGING SECURITY GATEWAY
F-SECURE MESSAGING SECURITY GATEWAY DEFAULT SETUP GUIDE This guide describes how to set up and configure the F-Secure Messaging Security Gateway appliance in a basic e-mail server environment. AN EXAMPLE
How To Enable A Websphere To Communicate With Ssl On An Ipad From Aaya One X Portal 1.1.3 On A Pc Or Macbook Or Ipad (For Acedo) On A Network With A Password Protected (
Avaya one X Portal 1.1.3 Lightweight Directory Access Protocol (LDAP) over Secure Socket Layer (SSL) Configuration This document provides configuration steps for Avaya one X Portal s 1.1.3 communication
Using IIS Application Request Routing to Publish Lync Server 2013 Web Services
Using IIS Application Request Routing to Publish Lync Server 2013 Web Services DISCLAIMER 2014 Microsoft Corporation. All rights reserved. Microsoft, Active Directory, Hyper-V, Internet Explorer, Lync,
Extreme Control Center, NAC, and Purview Virtual Appliance Installation Guide
Extreme Control Center, NAC, and Purview Virtual Appliance Installation Guide 9034968 Published April 2016 Copyright 2016 All rights reserved. Legal Notice Extreme Networks, Inc. reserves the right to
All rights reserved. Trademarks
All rights reserved This manual, as well as the software described in it, is furnished under license and may be used or copied only in accordance with the terms of such license. The content of this manual
TelePresence Migrating TelePresence Management Suite (TMS) to a New Server
TelePresence Migrating TelePresence Management Suite (TMS) to a New Server THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS,
WebTrends 7 Backup and Restore for MySQL Databases
WebTrends 7 Backup and Restore for MySQL Databases May 2004 Edition 2004 NetIQ Corporation Disclaimer This document and the software described in this document are furnished under and are subject to the
HP Data Protector Integration with Autonomy IDOL Server
HP Data Protector Integration with Autonomy IDOL Server Introducing e-discovery for HP Data Protector environments Technical white paper Table of contents Summary... 2 Introduction... 2 Integration concepts...
Integrated Citrix Servers
Installation Guide Supplement for use with Integrated Citrix Servers Websense Web Security Websense Web Filter v7.5 1996-2010, Websense, Inc. 10240 Sorrento Valley Rd., San Diego, CA 92121, USA All rights
Host your websites. The process to host a single website is different from having multiple sites.
The following guide will help you to setup the hosts, in case you want to run multiple websites on your VPS. This is similar to setting up a shared server that hosts multiple websites, using a single shared
DameWare Server. Administrator Guide
DameWare Server Administrator Guide About DameWare Contact Information Team Contact Information Sales 1.866.270.1449 General Support Technical Support Customer Service User Forums http://www.dameware.com/customers.aspx
Juniper Networks Network and Security Manager
Juniper Networks Network and Security Manager CentOS Upgrade Guide Release 2012.2 Modified: 2015-07-20 Revision 4 Juniper Networks, Inc. 1133 Innovation Way Sunnyvale, California 94089 USA 408-745-2000
Symantec Enterprise Vault Technical Note. Troubleshooting the Monitoring database and agents. Windows
Symantec Enterprise Vault Technical Note Troubleshooting the Monitoring database and agents Windows December 2006 Symantec Enterprise Vault Troubleshooting the Monitoring database and agents Copyright
CORPORATE HEADQUARTERS Elitecore Technologies Ltd. 904 Silicon Tower, Off. C.G. Road, Ahmedabad 380015, INDIA www.cyberoam.com
CYBEROAM LDAP INTEGRATION GUIDE VERSION: 7 IMPORTANT NOTICE Elitecore has supplied this Information believing it to be accurate and reliable at the time of printing, but is presented without warranty of
www.novell.com/documentation Administration Guide GroupWise Mobility Service 2.1 February 2015
www.novell.com/documentation Administration Guide GroupWise Mobility Service 2.1 February 2015 Legal Notices Novell, Inc. makes no representations or warranties with respect to the contents or use of this
Virtual LoadMaster for Microsoft Hyper-V
Virtual LoadMaster for Microsoft Hyper-V on Windows Server 2012, 2012 R2 and Windows 8 VERSION: 1.3 UPDATED: MARCH 2014 Copyright 2002-2014 KEMP Technologies, Inc. All Rights Reserved. Page 1 / 20 Copyright
Acronis SharePoint Explorer. User Guide
Acronis SharePoint Explorer User Guide Table of contents 1 Introducing Acronis SharePoint Explorer... 3 1.1 Supported Microsoft SharePoint versions... 3 1.2 Supported backup locations... 3 1.3 Licensing...
SUN COBALT RaQ 4 Server Appliance FAQ
SUN COBALT RaQ 4 Server Appliance - Frequently Asked Questions THE SUN COBALT RAQ 4 IS ADVANCING SERVER APPLIANCE TECHNOLOGIES BY INTEGRATING THE MOST POWERFUL TOOLS AND APPLICATIONS INTO A RELIABLE, LOW-COST
PHD Virtual Backup for Hyper-V
PHD Virtual Backup for Hyper-V version 7.0 Installation & Getting Started Guide Document Release Date: December 18, 2013 www.phdvirtual.com PHDVB v7 for Hyper-V Legal Notices PHD Virtual Backup for Hyper-V
Dell One Identity Cloud Access Manager 7.0.2. Installation Guide
Dell One Identity Cloud Access Manager 7.0.2 2014 Dell Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide is furnished under
CA ARCserve Replication and High Availability for Windows
CA ARCserve Replication and High Availability for Windows Microsoft SQL Server Operation Guide r15 This documentation and any related computer software help programs (hereinafter referred to as the "Documentation")
Enterprise Vault 6.0. SMTP Archiving
Enterprise Vault 6.0 SMTP Archiving Disclaimer The information contained in this publication is subject to change without notice. VERITAS Software Corporation makes no warranty of any kind with regard
Symantec Security Information Manager - Best Practices for Selective Backup and Restore
Symantec Security Information Manager - Best Practices for Selective Backup and Restore Symantec Security Information Manager - Best practices for selective backup and restore The software described in
Cisco Prime Central Managing Certificates
Cisco Prime Central Managing Certificates Version 1.0.5 September, 2015 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000
RealPresence Platform Director
RealPresence CloudAXIS Suite Administrators Guide Software 1.3.1 GETTING STARTED GUIDE Software 2.0 June 2015 3725-66012-001B RealPresence Platform Director Polycom, Inc. 1 RealPresence Platform Director
HP Intelligent Management Center v7.1 Virtualization Monitor Administrator Guide
HP Intelligent Management Center v7.1 Virtualization Monitor Administrator Guide Abstract This guide describes the Virtualization Monitor (vmon), an add-on service module of the HP Intelligent Management
Disaster Recovery. Websense Web Security Web Security Gateway. v7.6
Disaster Recovery Websense Web Security Web Security Gateway v7.6 1996 2011, Websense, Inc. All rights reserved. 10240 Sorrento Valley Rd., San Diego, CA 92121, USA Published 2011 The products and/or methods
TIBCO Spotfire Server Migration. Migration Manual
TIBCO Spotfire Server Migration Migration Manual Revision date: 26 October 2012 Important Information SOME TIBCO SOFTWARE EMBEDS OR BUNDLES OTHER TIBCO SOFTWARE. USE OF SUCH EMBEDDED OR BUNDLED TIBCO SOFTWARE
AG MacOS Standalone Array Client Administration Guide
AG MacOS Standalone Array Client Administration Guide Copyright Statement Copyright Statement Copyright 2015 Array Networks, Inc., 1371 McCarthy Blvd, Milpitas, California 95035, USA. All rights reserved.
Citrix Receiver for Mobile Devices Troubleshooting Guide
Citrix Receiver for Mobile Devices Troubleshooting Guide www.citrix.com Contents REQUIREMENTS...3 KNOWN LIMITATIONS...3 TROUBLESHOOTING QUESTIONS TO ASK...3 TROUBLESHOOTING TOOLS...4 BASIC TROUBLESHOOTING
Symantec Endpoint Protection Shared Insight Cache User Guide
Symantec Endpoint Protection Shared Insight Cache User Guide Symantec Endpoint Protection Shared Insight Cache User Guide The software described in this book is furnished under a license agreement and
SUSE Manager in the Public Cloud. SUSE Manager Server in the Public Cloud
SUSE Manager in the Public Cloud SUSE Manager Server in the Public Cloud Contents 1 Instance Requirements... 2 2 Setup... 3 3 Registration of Cloned Systems... 6 SUSE Manager delivers best-in-class Linux
CYBEROAM WINDOWS DOMAIN CONTROLLER INTEGRATION GUIDE VERSION:
7300-1.0-9/20/2005 1 CYBEROAM WINDOWS DOMAIN CONTROLLER INTEGRATION GUIDE VERSION: 7 7300-1.0-9/20/2005 2 IMPORTANT NOTICE Elitecore has supplied this Information believing it to be accurate and reliable
Foglight. Foglight for Virtualization, Free Edition 6.5.2. Installation and Configuration Guide
Foglight Foglight for Virtualization, Free Edition 6.5.2 Installation and Configuration Guide 2013 Quest Software, Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright.
Symantec NetBackup Appliance Getting Started Guide
Symantec NetBackup Appliance Getting Started Guide Release 2.0 NetBackup 5200 and 5220 The software described in this book is furnished under a license agreement and may be used only in accordance with
www.novell.com/documentation SSL VPN Server Guide Access Manager 3.1 SP5 January 2013
www.novell.com/documentation SSL VPN Server Guide Access Manager 3.1 SP5 January 2013 Legal Notices Novell, Inc., makes no representations or warranties with respect to the contents or use of this documentation,
NCD ThinPATH Load Balancing Startup Guide
NCD ThinPATH Load Balancing Startup Guide Copyright Copyright 1999 by Network Computing Devices, Inc. (NCD).The information contained in this document is subject to change without notice. Network Computing
SOFTWARE LICENSE LIMITED WARRANTY
CYBEROAM INSTALLATION GUIDE VERSION: 6..0..0..0 IMPORTANT NOTICE Elitecore has supplied this Information believing it to be accurate and reliable at the time of printing, but is presented without warranty
Lepide Active Directory Self Service. Installation Guide. Lepide Active Directory Self Service Tool. Lepide Software Private Limited Page 1
Installation Guide Lepide Active Directory Self Service Tool Lepide Software Private Limited Page 1 Lepide Software Private Limited, All Rights Reserved This User Guide and documentation is copyright of
Command Line Interface User Guide for Intel Server Management Software
Command Line Interface User Guide for Intel Server Management Software Legal Information Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel
Trouble Shooting SiteManager to GateManager access
Trouble Shooting SiteManager to GateManager access If you are unsure if a SiteManager will be able to access the GateManager through the corporate firewall, or you experience connection issues, this document
Version 4.61 or Later. Copyright 2013 Interactive Financial Solutions, Inc. All Rights Reserved. ProviderPro Network Administration Guide.
Version 4.61 or Later Copyright 2013 Interactive Financial Solutions, Inc. All Rights Reserved. ProviderPro Network Administration Guide. This manual, as well as the software described in it, is furnished
GX-V. Quick Start Guide. Microsoft Hyper-V Hypervisor. Before You Begin SUMMARY OF TASKS. Before You Begin WORKSHEET VIRTUAL GMS SERVER
Quick Start Guide GX-V VIRTUAL GMS SERVER Microsoft Hyper-V Hypervisor 2012 Silver Peak Systems, Inc. Before You Begin Windows 2008 server installed and Hyper-V is running Hyper-V management software is
RSA Security Analytics Virtual Appliance Setup Guide
RSA Security Analytics Virtual Appliance Setup Guide Copyright 2010-2015 RSA, the Security Division of EMC. All rights reserved. Trademarks RSA, the RSA Logo and EMC are either registered trademarks or
Clearswift SECURE Exchange Gateway Installation & Setup Guide. Version 1.0
Clearswift SECURE Exchange Gateway Installation & Setup Guide Version 1.0 Copyright Revision 1.0, December, 2013 Published by Clearswift Ltd. 1995 2013 Clearswift Ltd. All rights reserved. The materials
MailMarshal SMTP in a Load Balanced Array of Servers Technical White Paper September 29, 2003
Contents Introduction... 1 Network Load Balancing... 2 Example Environment... 5 Microsoft Network Load Balancing (Configuration)... 6 Validating your NLB configuration... 13 MailMarshal Specific Configuration...
Backup Exec Cloud Storage for Nirvanix Installation Guide. Release 2.0
Backup Exec Cloud Storage for Nirvanix Installation Guide Release 2.0 The software described in this book is furnished under a license agreement and may be used only in accordance with the terms of the
Privileged Access Management Upgrade Guide
Privileged Access Management Upgrade Guide 2015 Bomgar Corporation. All rights reserved worldwide. BOMGAR and the BOMGAR logo are trademarks of Bomgar Corporation; other trademarks shown are the property
Symantec AntiVirus Corporate Edition Patch Update
Symantec AntiVirus Corporate Edition Patch Update Symantec AntiVirus Corporate Edition Update Documentation version 10.0.1.1007 Copyright 2005 Symantec Corporation. All rights reserved. Symantec, the Symantec
Secure Messaging Server Console... 2
Secure Messaging Server Console... 2 Upgrading your PEN Server Console:... 2 Server Console Installation Guide... 2 Prerequisites:... 2 General preparation:... 2 Installing the Server Console... 2 Activating
BBI Quick Guide HP GbE2c L2/L3 Ethernet Blade Switch Version 5.1
BLADE OS BBI Quick Guide HP GbE2c L2/L3 Ethernet Blade Switch Version 5.1 Part Number: BMD00116, August 2009 2350 Mission College Blvd. Suite 600 Santa Clara, CA 95054 www.bladenetwork.net Copyright 2009
Symantec NetBackup Desktop and Laptop Option README. Release 6.1 MP7
TM Symantec NetBackup Desktop and Laptop Option README Release 6.1 MP7 2 The software described in this document is furnished under a license agreement and may be used only in accordance with the terms
Enterprise Content Management System Monitor. Server Debugging Guide. 20.09.2013 CENIT AG Bettighofer, Stefan
Enterprise Content Management System Monitor Server Debugging Guide 20.09.2013 CENIT AG Bettighofer, Stefan 1 Table of Contents 1 Table of Contents... 2 2 Overview... 3 3 The Server Status View... 3 4
Symantec NetBackup PureDisk Deduplication Option Guide
Symantec NetBackup PureDisk Deduplication Option Guide Windows, Linux, and UNIX Release 6.6.5 Revision 1 The software described in this book is furnished under a license agreement and may be used only
Isilon OneFS. Version 7.2.1. OneFS Migration Tools Guide
Isilon OneFS Version 7.2.1 OneFS Migration Tools Guide Copyright 2015 EMC Corporation. All rights reserved. Published in USA. Published July, 2015 EMC believes the information in this publication is accurate